FOR REFERENCE RESUB1 BLD2024-0891+COMPLETE ELECTRICAL PLAN+8.26.2024_7.57.47_AM+4461410
GENERALNOTES ABBREVIATIONS ELECTRICAL LEGEND (LEGEND IS GENERAL IN NATURE. NOT ALL OF THE SYMBOLS SHOWN ARE USED IN THIS PROJECT.) (RE: ALL ELECTRICAL SHEETS) A AMPERES POWER LIGHTING (SEE LUMINAIRE SCHEDULE FOR EXACT MISCELLANEOUS SWITCHES ONE LINE AC ABOVE COUNTER REQUIREMENTS) 1. ALL ELECTRICAL EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL AFF ABOVE FINISHED FLOOR SIMPLEX OUTLET. +18" AFF UNO. ® SINGLE FACE EXIT SIGN. CEILING MOUNTED. Q) JUNCTION BOX. S# SWITCH. TYPE AS INDICATED. +46"AFF, UNO. CODE, INTERNATIONAL FIRE CODE, AND ALL OTHER STATE AFG ABOVE FINISHED GRADE 0 DUPLEX OUTLET. +18" AFF UNO. ® DOUBLE FACE EXIT SIGN. CEILING MOUNTED. 2 DOUBLE POLE BRANCH AND LOCAL CODES. CONTRACTOR SHALL IMMEDIATELY AF AMPERE FRAME J� JUNCTION BOX, WALL MOUNTED. 3 3-WAY PANEL BRANCH PANEL. NOTIFY ENGINEER IN WRITING IF PORTIONS OF THE DESIGN AHJ AUTHORITY HAVING JURISDICTION I DUPLEX OUTLET. MOUNTED ABOVE COUNTER UNO. 4 4-WAY ****** SET OR FIELD CONDITIONS DO NOT MEET REQUIRED CODES. AT AMP TRIP DUPLEX OUTLET. +18" AFF UNO WITH GROUND SINGLE FACE EXIT SIGN. WALL MOUNTED. � THERMOSTAT. +56" AFF UNO. UNIT CONTROLLED D DIMMER INDICATED. 2. PROVIDE FIRESTOPPING FOR ALL FLOOR AND FIREWALL AWG AMERICAN WIRE GAUGE 0 FAULT INTERRUPTION PROTECTION. DOUBLE FACE EXIT SIGN. WALL MOUNTED. F CEILING FAN CONTROLLER HP HORSE POWER RATED PENETRATIONS FROM ELECTRICAL DEVICE, RACEWAY, AND CABLE PENETRATIONS. SEE ARCHITECTURAL DRAWINGS FOR BW BLANKET WARMER � DUPLEX OUTLET. MOUNTED ABOVE COUNTER UNO SURFACE MOUNTED PAN ELBOARD/ENCLOSURE. � K KEYED FIREWALL LOCATIONS. C CONDUIT WITH GROUND FAULT INTERRUPTION PROTECTION. SINGLE FACE COMBO EXIT SIGN / EMERGENCY LUMINAIRE. WALL MOUNTED. SEE SCHEDULE FOR TYPE. LV LOW VOLTAGE � A CIRCUIT BREAKER. SIZE AND TYPE 3. FIRE ALARM SYSTEM IS DESIGN BUILD BY ELECTRICAL CB CIRCUIT BREAKER SWITCHED DUPLEX OUTLET. +18" AFF UNO. FLUSH MOUNTED PANELBOARD/ENCLOSURE. M MOMENTARY CONTACT / I AS SPECIFIED. CONTRACTOR AND SHALL BE INSTALLED IN ACCORDANCE CC CRASH CART DUPLEX ISOLATED GROUND OUTLET. � ARROW INDICATES DIRECTION TO BE SEE SCHEDULE FOR TYPE. MM MANUAL MOTOR STARTER WITH NFPA 72 AND ALL OTHER STATE AND LOCAL CODES. CKT CIRCUIT +18" AFF UNO. SHOWN ON SIGN. OS OCCUPANCY SENSOR PROVIDE AND INSTALL CONDUIT AND CONDUCTORS FOR ALL FIRE ALARM DEVICES REQUIRED BY LOCAL AUTHORITY CL CRITICAL LOAD DUPLEX ISOLATED GROUND OUTLET. � LIGHT FIXTURE. AM MECHANICAL EQUIPMENT SYMBOL (RE: MECHANICAL DRAWINGS FOR EXACT LOCATION P PILOT LIGHT T 15 MINUTE TIMER I 30AF CIRCUIT BREAKER. FRAME SIZE AF ( ) AND TRIP PLUG/RATING AT 3 POLE, ( ), CM CEILING MOUNTED � COUNTER # / 30AT / UNO. HAVING JURISDICTION, INCLUDING BUT NOT LIMITED TO HVAC MOUNTED ABOVE UNO. LIGHT FIXTURE. OF UNITS). TO THERMAL OVERLOAD SHUTDOWN, FIRE ALARM CONTROL PANEL, INITIATING AND CO CONDUIT ONLY, PROVIDE PULL -LINE DUPLEX 20A OUTLET. +18" AFF UNO. INDICATES FIXTURE TYPE. REFER TO LUMINARE V VOLUME CONTROL ANNUNCIATING CIRCUITS. FIELD INSPECTION IS REQUIRED TO D MECHANICAL DUCT -MOUNTED DEVICE LIGHT FIXTURE. C SCHEDULE. VS VACANCY SENSOR VERIFY THIS INFORMATION PRIOR TO BID. DC DIRECT CURRENT DUPLEX 20A OUTLET. MOUNTED ABOVE COUNTER UNO. a SUPERSCRIPT INDICATES LIGHTS 15A FUSE. SIZE AND TYPE AS 4. PROVIDE AND INSTALL 3/4" CONDUIT WITH BUSHING AND PULL DET DETAIL TO BE SWITCHED TOGETHER SPECIFIED, CIRCUITING SYMBOLS CORD TO ABOVE ACCESSIBLE CEILING, UNLESS NOTED E EMERGENCY/CRITICAL CARE DUPLEX OUTLET WITH USB PORT. +18" AFF UNO. SUSPENDED LIGHT FIXTURE. PROVIDE FUSE FOR EACH POLE, 3 OTHERWISE FOR DATA, TELEPHONE, AND TELEVISION (E) EXISTING WALL MOUNTED FIXTURE. %MULTI -LEVEL SWITCHING, TO MEET LIGHT POLE, UNO. DEVICES. DATA, TELEPHONE, AND TELEVISION CABLING ARE EF EXHAUST FAN SINGLE 20A OUTLET. +18" AFF UNO. CONDUIT STUBBED, CAPPED, AND REDUCTION LEVELS PER ENERGY CODE AS NOT PROVIDED UNDER THIS CONTRACT. WALL SCONCE FIXTURE. MARKED WITH PULL CORD. SHOWN. PROVIDE ADDITIONAL OR STEP- 30A INTERRUPTER SWITCH. SIZE AS 5. EMERGENCY LIGHTING SYMBOLS ARE SHADED ON THE EL EMERGENCY LIGHT FOURPLEX OUTLET. +18" AFF UNO. DIMMING BALLASTS WHERE REQUIRED. INDICATED, 3 POLE, UNO. LIGHTING PLANS. EMERGENCY SOURCE SHALL BE BATTERY EWC ELECTRIC WATER COOLER FOURPLEX OUTLET. MOUNTED ABOVE WALL PACK FIXTURE. CONDUIT UP. BACKED DRIVER WITH MINIMUM OF 1400 LUMEN OUTPUT FOR EWH ELECTRIC WATER HEATER COUNTER UNO. OCCUPANCY SENSOR. CEILING MOUNTED. A 90 MINUTE PERIOD, UNLESS NOTED OTHERWISE. PROVIDE F FUSE UNDERCABINET MOUNTED FIXTURE. CONDUIT DOWN. UNSWITCHED CONDUCTORS FOR CHARGING CIRCUIT AS FACP FIRE ALARM CONTROL PANEL FOURPLEX ISOLATED GROUND OUTLET+18" AFF UNO. . OF—vv TRACKLIGHT. —� X-# HOMERUN. PANEL AND CIRCUIT AS P 4 . . PHOTOCELLWALL MOUNTED REQUIRED. FUSED SWITCH. SWITCH SIZE (AS) & 6. ALL WIRING DEVICES SHALL BE OF THE SAME MANUFACTURER FVNR FULL VOLTAGE NON -REVERSING � FOURPLEX ISOLATED GROUND OUTLET. MOUNTED � PENDANT LIGHT FIXTURE. INDICATED. 30AS 30AF FUSE SIZE (AF) AS INDICATED, 3 AND SHALL MATCH THROUGHOUT. Cn\/FR PLATES SHALL BE G/GND GROUND ABOVE COUNTER UNO. CIRCUIT CONCEALED IN CEILING OR O PHOTOCELL. CEILING MOUNTED. POLE, UNO. STAINLESS AND DEVICES SHALL BE COORDINATED WITH THE GFI GROUND FAULT INTERRUPTION SPECIAL PURPOSE OUTLET. VERIFY SIZE AND TYPE r1 ROUND DECORATIVE LIGHT FIXTURE. W WALL. I, TIMECLOCK. WALL MOUNTED. ARCHITECT. GFP GROUND FAULT PROTECTION WITH EQUIPMENT SUPPLIER. SURFACE MOUNT C YYY 7. DESIGN OF ELECTRICAL REQUIREMENTS IS BASED ON H HEAT ® CONNECTION POINT TO EQUIPMENT SPECIFIED, Q RECESSED LIGHT FIXTURE. CIRCUIT CONCEALED IN FLOOR OR SINGLE BUTTON, WALL MOUNTED MECHANICAL EQUIPMENT SPECIFIED. ELECTRICAL HH HANDHOLE FURNISHED, AND INSTALLED UNDER OTHER SECTIONS. UNDERGROUND. _ 4 PUSHBUTTON. MOUNT AT SWITCH HEIGHT UNO. CONTRACTOR SHALL COORDINATE WITH MECHANICAL HOA HAND OFF AUTO ELECTRICAL CONTRACTOR TO SUPPLY RACEWAY AND � RECESSED WALL WASH LIGHT FIXTURE. DRAW OUT CIRCUIT BREAKER FRAME CONTRACTOR IF EQUIPMENT PURCHASED IS DIFFERENT FROM HID HIGH INTENSITY DISCHARGE CONDUCTORS AND MAKE FINAL CONNECTION TO ® THREE BUTTON, WALL MOUNTED PUSHBUTTON. (AF) SIZE AND TRIP PLUG RATING THAT SPECIFIED STILL MEETS DESIGN INTENT, INCLUDING BUT EQUIPMENT UNDER THIS SECTION, UNO. PORCELAIN LAMP HOLDER. GROUNDING MOUNT AT SWITCH HEIGHT UNO. �/ (AT), 3 POLE, UNO. NOT LIMITED TO OVER -CURRENT PROTECTION, LOCAL DISCONNECTING MEANS, AND WIRE SIZING. HP HVAC HOUSE PHONE HEATING, VENTILATING, & AIR CONDITIONING ® DUPLEX OUTLET. FLUSH, FLOOR MOUNTED WITH WALL MOUNTED PORCELAIN LAMP HOLDER. CONDUCTOR SIZE MOTOR STARTER/CONTACTOR. 8. IT SHALL BE CONTRACTORS RESPONSIBILITY TO VERIFY TYPE I IONIZATION BRASS COVE PLATE. DUPLEX SWITCHED OUTLET. FLUSH, FLOOR MOUNTED CEILING FAN. X"-X#X X#XG INDIVIDUAL BREAKER FRAME (AF) OF CEILING SYSTEMS AND TO FURNISH APPROVED LIGHTING ID IN -DUCT ® [KJ COMBINATION STARTER AND DISCONNECT. FIXTURES OF THE TYPE REQUIRED FOR MOUNTING IN SUBJECT CEILING. WHERE FIXTURES ARE RECESSED IN IC IG INTERRUPTING CAPACITY ISOLATED GROUND ® WITH BRASS CO\/FR PLATE. DUPLEX ISOLATED GROUNQ OUTLET. FLUSH, FLOOR CEILING FAN WITH LIGHT KIT. RACEWAY SIZE - CONDUCTOR SIZE CONDUCTOR QUANTITY X D NON -FUSED DISCONNECT SWITCH. SIZE AS SIZE AND TRIP PLUG RATING (AT), NEMA 1 UNO, 3 POLE UNO. PLASTER OR DRYWALL CEILINGS, THEY SHALL BE COMPLETE FR PLATE. MOUNTED WITH BRASS C(,� INDICATED, NEMA 1 UNO, 3 POLE UNO. WITH NECESSARY MOUNTING HARDWARE AND PLASTER J/JB JUNCTION BOX FOURPLEX OUTLET. FLUSH, FLOOR MOUNTED WITH FRAMES. KW KILOWATT ® BRASS CO\/FR PLATE. —0 POLE LIGHT 1 HEAD ROUND WITH POLE. 9. ALL RECESSED LIGHTING FIXTURES, SPEAKERS, KWH KILOWATT HOUR OHO POLE LIGHT 2 HEAD ROUND WITH POLE. CIRCUIT SHALL CONSIST OF 3/4"-2#12,1#12G UNLESS F X FUSED DISCONNECT SWITCH. SIZE AS O METER. RECEPTACLES, SWITCHES, ETC., MOUNTED IN THE FIRE M MAGNETIC CONTACTOR COIL ®❑ SPECIAL PURPOSE OUTLET. FLUSH, FLOOR MOUNTED NOTED OTHERWISE. INDICATED, NEMA 1 UNO, 3 POLE UNO. RATED CEILINGS OR WALLS SHALL BE ENCLOSED WITH AN MB MAIN BREAKER WITH BRASS CO\/FR"PLATE. -0 POLE LIGHT 1 HEAD SQUARE WITH POLE. AM AMMETER. APPROVED ENCLOSURE CARRYING THE SAME FIRE RATING AS MCC MOTOR CONTROL CENTER MOTOR CONNECTION. RE: MECHANCIAL CONTRACTOR SHALL ROUTE CIRCUIT HOMERUN THE CEILING OR WALL BY THIS CONTRACTOR. MLO MAIN LUGS ONLY EQUIPMENT SCHEDULE ❑-0 POLE LIGHT 2 HEAD SQUARE WITH POLE. FROM DEVICE NEAREST THE PANEL. VM VOLTMETER. 10. ALL COMMUNICATIONS CONDUIT SHALL BE 3/4" UNO. MS MOTOR STARTER IC O BOLLARD LIGHT. O ADA DOOR CHIME/STROBE ❑K KIRK KEY LOCK. MOUNTING T I N HEIGHTS I H T DETAIL O U G G S MH MANHOLE MW MICROWAVE � DECORATIVE POST -TOP LIGHT. GFP GROUND FAULT PROTECTION. SHEET INDEX N NEUTRAL FIRE ALARM SPOT/FLOOD LIGHT. NC NCL NORMALLY CLOSED NON CRITICAL LOAD Sp O SMOKE DETECTOR, ADDRESSABLE, CEILING EMERGENCY EGRESS LIGHT. WALL MOUNTED. TVSS TRANSIENT VOLTAGE SURGE SUPRESSION. EO_00 ELECTRICAL COVER SHEET NEC NATIONAL ELECTRICAL CODE MOUNTED, UNO. p�� EMERGENCY EGRESS LIGHT. CEILING MOUNTED. ST SHUNT TRIP COIL. CC N RG OMP IA C i�i�EMECTRECALITE PLAN NIC NOT IN CONTRACT CO CARBON MONOXIDE DETECTOR. KWH KILOWATT HOUR METER. ® PHOTOMETRIC PLAN SITE & LEVEL 1 NO NORMALLY OPEN KEYED NOTES COMMUNICATIONS - PHOTOMETRIC PLAN - LEVEL P1 NTS NOT TO SCALE FSD FIRE/SMOKE DAMPER A. 1. 48" AFF MEASURED FROM THE TOP OF THE KVAR KILOVAR DEMAND METER. �m Ir"I Il.i TYP. CORRIDOR & UNIT PHOTOMETRIC PLANS OL OS OVERLOAD OCCUPANCY SENSOR F L-177 IIF F / OUTLET BOX. TEST TEST BLOCK. ® ELECTRICAL LIGHTING PLAN -LEVEL P1 n1 ELECTRICAL LIGHTING PLAN LEVEL 1 OFCI OWNER FURNISHED CONTRACTOR INSTALLED SD LOW FREQUENCY SOUNDER W/ 177CD STROBE MOUNTED TO THE CEILING. ]Z COMMUNICATION OUTLET LOCATED AT 18" AFF UNO. 1 2. 46" AFF MEASURED FROM THE TOP OF THE - �? n? ELECTRICAL LIGHTING PLAN -LEVEL 2 P PHOTO S PROVIDE AND INSTALL 4" SQUARE, DEEP JUNCTION BOX WITH SINGLE GANG MUD RING OUTLET BOX WHERE LOCATED ABOVE SOLID BASE CABINET THAT ALLOWS OVERHEAD SERVICE DROP. PC PHOTOCELL ELECTRICAL LIGHTING PLAN -LEVEL 3 F L F a ❑p ❑i ® PARALLEL (SIDE) APPROACH. APPLIES IN ELECTRICAL LIGHTING PLAN -LEVEL 4 PVC RCPT POLYVINYL CHLORIDE RECEPTACLE0�0 SD LOW FREQUENCY SOUNDER. � COMMUNICATION OUTLET. FLUSH, FLOOR MOUNTED. � J O � TYPE B/FHA UNITS ONLY. ^tea GENERATOR SET. MAIN BREAKER ELECTRICAL LIGHTING PLAN - LEVEL 5 (R) RELOCATED S � ❑P I* S# z z OF SIZE ELECTRICAL LIGHTING PLAN -LEVEL 6 AUDIBLE /VISUAL HORN -STROBE SMOKE (�j TELEVISION OUTLET LOCATED AT 18" AFF UNO. O O 3. 44" AFF MEASURED FROM THE TOP THE OUTLET BOX WHERE LOCATED ABOVE INDICATED. ELECTRICAL POWER PLAN -LEVEL P1 RE ( ) REPLACED F 177 DETECTION DEVICE. CEILING MOUNTED, UNO. Y PROVIDE AND INSTALL AS A RECESSED OUTLET. PANEL U ADA AT w J - OPEN-FACED CABINET. APPLIES IN TYPE A �+ TRANSFER SWITCH. © ELECTRICAL POWER PLAN - LEVEL 1 REF SPST REFRIGERATOR SINGLE POLE SINGLE THROW NUMBER INDICATES CANDELA OF DEVICE. OUTLET. J w COUNTER MAX iO CO z Q Q [-- UNITS AND COMMON AREAS ONLY. ® ELECTRICAL POWER PLAN - LEVEL 2 VISUAL STROBE - SMOKE DETECTION DEVICE. TELEVISION FLUSH, FLOOR MOUNTED. _ Lo w GUTTER. © ELECTRICAL POWER PLAN -LEVEL 3 TC TDR TIME CLOCK TIME DELAY RELAY F 177 CEILING MOUNTED, UNO. SO SPEAKER. CEILING MOUNTED WITH BACKBOX. - o_ - I� k�k IG b N 4. OUTLET ABOVE BASE CABINET IN 'U' SHAPED KITCHEN TO BE PROVIDED AT ® ELECTRICAL POWER PLAN -LEVEL 4 O O METER AND BASE. © ELECTRICAL POWER PLAN LEVEL 5 TJB TERMINAL JUNCTION BOX I VISUAL STROBE -SMOKE DETECTION DEVICE. n SPEAKER. WALL MOUNTED WITH BACKBOX +80" UNO. 0 " MINIMUM OF 36" FROM A CORNER. (MAY - 1R TSP TWISTED SHIELDED PAIR i� WALL MOUNTED, UNO. Y 00 REQUIRE ADDITIONAL OUTLETS BEYOND NEUTRA NEUTRAL. ELECTRICAL POWER PLAN - LEVEL 6 17 TTB TELEPHONE TERMINAL BOARD FIRE WATER FLOW BELL WIRELESS PULL CORD. ARLINGTON F101 LOCATED FINISH FLOOR THOSE REQUIRED BY CODE). 2 ELECTRICAL POWER PLAN - ROOF E�220 ELECTRICAL ENLARGED UNITS TVSS TRANSIENT VOLTAGE SURGE SUPPRESSER ADDRESSABLE MANUAL PULL STATION �P AT 48" AFF TO CENTER OF BOX. NO CONDUIT REQUIRED. B. LOCATED NO LESS THAN 15"AFF MEASURED PM POWER MONITORING ELECTRICAL ENLARGED UNITS TYP TYPICAL FROM THE BOTTOM OF THE OUTLET BOX. UH UNIT HEATER I D E S B E IN E E D L �p� CAMERA. WALL MOUNTED AT 96" AFF UNO. PROVIDE ® ELECTRICAL ENLARGED KITCHEN PLANS &SCHEDULE UNO UNLESS NOTED OTHERWISE ; 4" SQUARE, DEEP JUNCTION BOX WITH SINGLE GANG C. OUTLETS AND SWITCHES OVER COUNTERS, ® SPECIAL SYSTEMS POWER PLAN - P1 V VOLT ANN ANNUNCIATOR PANEL MUD RING AND 3/4"CONDUIT TO THE NEAREST IDF. 8" TO CENTER OF BOX ABOVE COUNTERS, © SPECIAL SYSTEMS POWER PLAN - LEVEL 1 OR 10" TO TOP OF BOX ABOVE COUNTER. ® SPECIAL SYSTEMS POWER PLAN - LEVEL 2 VA VOLT AMPERE UAP UNIT ACCESS PANEL. LOW VOLTAGE CONTRACTOR ® SPECIAL SYSTEMS POWER PLAN - LEVEL 3 WG PROVIDE PROTECTIVE WIRE GUARD (LVC)PROVIDED ELECTRICAL CONTRACTOR ® SPECIAL SYSTEMS POWER PLAN -LEVEL 4 WP WEATHER PROOF/NEMA 3R FS FLOW SWITCH INSTALLED. MOUNTED AT 60" AFF TO TOP. r 1�! SPECIAL SYSTEMS POWER PLAN - LEVEL 5 XFMR TRANSFORMER COORDINATE WITH LVC FOR REQUIREMENTS. " F.2 Y SPECIAL SYSTEMS POWER PLAN - LEVEL 6 TS TAMPER SWITCH ® ELECTRICAL SCHEDULES F 71 ELECTRICAL SCHEDULES KNO KNOX BOX E4 nn ONE -LINE DIAGRAM (MDP-1) F n1 ONE -LINE DIAGRAM (MDP-2) DH DOOR HOLD rF,, nn ELECTRICAL DETAILS HD HEAT DETECTOR NOTE: PROVIDE AND INSTALL 3/4" CONDUIT WITH BUSHING AND PULL CORD TO ABOVE ACCESSIBLE CEILING, UNLESS NOTED OTHERWISE FOR DATA, TELEPHONE, AND TELEVISION DEVICES. DATA, TELEPHONE, AND TELEVISION CABLING ARE NOT PROVIDED UNDER THIS CONTRACT. p,N - G ASy/ G we � Z o IFS FGI1 ER�� G��'�7 S/DNAL EN 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD 00 d) 0 Z z O = Q W o LL z O0 0 z O N > J O� rn O 0 0 Z Il z m F_ LLl p Z oN U ~ � Q LU N U a REVISIO N DATE REASON FOR ISSUE 5 03/14/22 Construction Set ELECTRICAL COVER SHEET CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 ISHEET NUMBER —,oil EO.00 c r� LIGHTING COMPLIANCE SUMMARY 2015 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2023 NEEA, All rights reserved Project & Applicant Information Project Title Anthology of Edmonds - 2015 WSEC For Building Department Use: Date' Jan 06, 2023 Project Address 21200 72nd Ave. W. Edmonds, WA 98026 Applicant Name DC Engineering Applicant Phone 208-288-2181 Applicant Email vmurphy@dcengineering.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Group R - R2, R3 & R4 over 3 stories and all Rl General Building Use Type Multifamily/Residential Building Cond. Floor Area 164,000 General Project Types New Building New Building or Addition Lighting Scope Interior Lighting Parking Garage Lighting Exterior Lighting Alteration Lighting Scope Project Cond. Floor Area 164,000 Floors Above Grade 6 Compliance Method Compliance Method 1 - General Lighting Project Description Lighting Compliance Scope Project Type Interior / Exterior (Interior includes both interior & parking) Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification and Method New Building Interior Lighting Building area Reduced lighting power density option COMPLIES New Building Exterior Lighting Not applicable to exterior COMPLIES Additional Efficiency Reduced lighting power density option Options Included rojec Itle I Anthology of Edmonds - 2015 WSEC Date Jan 06, 2023 Lighting Power Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES Compliance Method Building area LPA Calculation Adjustment LPA x 0.75 Interior Lighting Power Allowance - Building Area Building Areas Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 0.75) Total Proposed Watts By Building Area Compliance Status by Building Area Multifamily 164,000 0.41 50,430 49,292 COMPLIES Parking Garage 35,311 0.16 4,238 1,458 COMPLIES Proposed Lighting Power Density Fixture Type/Application Fixture ID Building Area New or Existing -to -Remain Quantity of Fixtures, CLDs or Luminaires (#F) Watts per Fixture, or Luminaira ((WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer GLl Multifamily New 15 42 623 Troffer GL2 Multifamily New 41 22 882 Suspended PDl Multifamily New 5 8 40 Suspended PD2 Multifamily New 1 80 80 Suspended PD3 Multifamily New 3 5 15 Suspended PD4 Multifamily New 2 18 36 Suspended PD5 Multifamily New 3 30 90 Suspended PD6 Multifamily New 4 6 24 Suspended PD7 Multifamily New 1 9 9 Suspended PD8 Multifamily New 1 1 9 1 1 9 Suspendedl PD9 Multifamily New 2 1 9 1 1 18 Suspendedl PD10 I Multifamily New 1 1 9 1 1 9 Wall -mounted UE E2.20-E2.21 LED Multifamily I New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Wall -mounted OF E2.20-E2.21 LFD Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type B1 E2.00-E2.06 LEI) Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type B2 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type SMl E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type SM2 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type SI E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type S2 E2.00-E2.06 L F D Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type S3 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type S4 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type UA E2.20-E2.21 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type UB E2.20-E2.21 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type UC E2.20-E2.21 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Other fixture type SLl/SL1E E2.00-E2.01 LED Parking Garage New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Project Title Anthology of Edmonds - 2015 WSEC Date Jan 04, 2023 Lighting Power Calculation NEW BUILDING - EXTERIOR LIGHTING Compliance Verification I COMPLIES Exterior Lighting Zone ZONE 4 Base Site Allowance 1300 Exterior Tradable Lighting Power Allowance Tradable Surface Tradable Surface Sub -Type Surface I PA I Linear LPA Total Watts Allowed Total Tradable Tradable Compliance Area (SF) (Watts/SF) Feet (LF) I (Watts/LF) (LPA x SF) or Proposed Watts I Status Suspended PDII Multifamily New 5 7 33 Suspended PD12 Multifamily New 5 49 245 Suspended PD13 Multifamily New 4 42 168 Suspended PD14 Multifamily New 2 14 27 Suspended PD15 Multifamily New 3 9 27 Suspended PD16 Multifamily New 1 36 36 Suspended PD17 Multifamily New 4 35 140 Suspended PD18 Multifamily New 5 12 60 Wall -mounted V1,V2 Multifamily New 6 22 132 Wall -mounted V3 Multifamily New 1 35 35 Wall -mounted WD2 Multifamily New 127 6 762 Wall -mounted UD Multifamily New 153 36 5,508 Wall -mounted UE Multifamily New 265 10 2,756 Wall -mounted OF Multifamily New 23 10 230 Other fixture type B 1 Multifamily New 225 30 6,750 Other fixture type B2 Multifamily New 83 9 747 Other fixture type SM1 Multifamily New 66 20 1,320 Other fixture type SM2 Multifamily New 38 14 532 Other fixture type S 1 Multifamily New 28 30 840 Other fixture type S2 Multifamily New 2 17 34 Other fixture type S3 Multifamily New 1 32 32 Other fixture type S4 Multifamily New 79 52 4,108 Other fixture type UA Multifamily New 819 15 1 1 12,285 Other fixture type UB Multifamily New 421 25 10,525 Other fixture type UC Multifamily New 9 6 54 Other fixture type 1 SL1/SL1E Parking Garage New 54 27 1,458 Project Anthology of Edmonds - 2015 WSEC Date Jan 04, 202 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTIN Fixture Type/Application Fixture ID Location in Documents Lamp Type Building Area 7! New or Existing -to -Remain Individual Fixtures Troffer GLl E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Troffer GL2 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD1 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD2 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD3 E2.00-E2.06 LED Multifamily Nc a Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD4 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PDS E2.00-E2.06 LED Multifamily New (LPA x LF) Building grounds Walkways 10 feet and wider 1 5,400 1 0.20 1 1,080 Building entrances and exits Other entry/exit doors 12 20 240 Base Site Allowance 1300 Totals 2,620 38o COMPLIES Proposed Tradable Lighting Power Density Fixture Type Fixture ID Tradable Surface Type Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Wall -mounted WL1/WL1E Building grounds - Walkways 10 feet and wider 20 1 1 157 Wall -mounted WDI Building entrances and exits - Other entry/exit doors 17 A 10 170 Wall -mounted WL1E Building entrances and exits - Other entry/exit doors 2 20 39 Other fixture type RRl E Building entrances and exits - Other entry/exit doors '—CCD 003 21 21 386.5 Tradable Proposed Total Remaining Base Site Allowance Watts 1300.00 Exterior Non -Tradable Lighting Power Allowance Non -Tradable Surface Non -Tradable Surface Sub -Type Surface Area (SF) LPA (Watts/SF) # of Items LPA (Watts per # of items) Total Watts Allowed (LPA x SF) or (LPA x # of Items) Total Nan -Tradable Proposed Watts by Surface Type Non -Tradable Proposed Watts Exceeding LPA Non -Tradable Compliance Status Building fagade 1,635 0.150 245 103 Total Proposed Watts Exceeding LPA 0 Remaining Base Site Allowance 1,300 COMPLIES Proposed Non -Tradable Lighting Power Density Watts or Total Watts Fixture Type Fixture ID Tradable Surface Type Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixture Other fixture type I RRl Building fagade - 1 5 1 21 1 1 103 Project Title Anthology of Edmonds - 2015 WSEC Date Jan 04, 2023 Proposed Fixtures Details NEW BUILDING - EXTERIOR LIGHTING Fixture Type Fixture ID Location in Documents Lamp Type Tradable Surface Type New or Existing -to -Remain Individual Fixtures Wall -mounted WL1/WL1E E2.01 LED Building grounds - Walkways 10 feet and wider New Fixture Description: Are specific exterior lighting controls required?: Wall -mounted WD1 E2.01 LED Building entrances and exits - Other entry/exit doors New Fixture Description: Are specific exterior lighting controls required?: Wall -mounted WL1E E2.01 LED Building entrances and exits - Other entry/exit doors New Fixture Description: Are specific exterior lighting controls required?: Other fixture type RR1E E2.01 LED Building entrances and exits - Other entry/exit doors New Fixture Description: Are specific exterior lighting controls required?: Fixture Type Fixture ID Location in Documents Lamp Type I Non -Tradable Surface Type I New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD6 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD7 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD8 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD9 r E2.00-E2.06 LEI) Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD 10 E2.00-E2.06 L F D Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD11 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD12 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD13 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD14 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD15 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD16 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD17 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Suspended PD18 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Wall -mounted V1,V2 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Wall -mounted V3 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Wall -mounted WD2 E2.00-E2.06 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: Wall -mounted UD E2.20-E2.21 LED Multifamily New Fixture Description: Are these fixtures within a daylight zone?: Are specific application lighting controls required?: or Existing -to -Remain Individual Fixture Other fixture type RRl E2.01 Building fagade - New Are specific exterior lighting controls required?: PN A. G ASN/ c 'L O £t cP0 � Z f A �FSRF�ISTERE�G����� S/DNAL EN 01/06/23 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N 0 00 0 Z z O = Q W cn 0 LL z O0 0 z O Q> > J > J O O N 0 � z m F_ w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 5 03/14/22 Construction Set 12/30/22 CCD 003 ELECTRICAL IECC ENERGY COMPLIANCE CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 1 1 ELECTRICAL RICAL ITE PLAN NORTH SITE GENERAL NOTES 1. CONTRACTOR SHALL CONTACT UNDERGROUND UTILITY LOCATING SERVICE PRIOR TO EXCAVATION FOR ELECTRICAL WORK. 2. CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH ALL OTHER SITE DISCIPLINES INCLUDING BUT NOT LIMITED TO TRADES ASSOCIATED WITH WATER, SEWER, AND GAS INSTALLATIONS. 3. ELECTRICAL CONTRACTOR SHALL COORDINATE UTILITY WORK REQUIRED BY SERVING UTILITY AND SHALL FORWARD SERVING UTILITY WORK ORDER INVOICE TO OWNER FOR PAYMENT BY OWNER. 4. ROUTE ALL EXTERIOR LIGHTING (INCLUDING SOFFIT AND AREA LIGHTING SHORN C N SHEET F9 ni) THROUGH A LIGHTING CONTROL PANEL. LOCATE LIGHTING CONTROL PANEL IN IDF P,OOM 1018. PROVIDE PHOTO -CELL ON ROOF. REFER TO UHF :T F.ri nr/3. 5 MDP-1 & 2 DIMENIONS ARE BASED ON EATON POW-R-LINE C. AUTOMATIC TRANSFER SWITCH DIMENSIONS ARE BASED ON GENERAC. PRIOR TO ORDERING FINAL EQUIPMENT, CONFIRM PHYSICAL DIMENSIONS AND THE SPACE REQUIREMENTS. NOTIFY DESIGN TEAM OF ANY CONFLICTS. 6 REFER TO SHEETE'i nn FOR LUMINAIRE SCHEDULE. O APPROXIMATE ROUTING/LOCATION OF SERVING UTILITY PRIMARY UNDERGROUND CONDUIT/CONDUCTORS. SHOWN FOR REFERENCE ONLY. PRIMARY CONDUIT, CONDUCTORS AND TERMINATIONS BY SERVING UTILITY. NEW TRANSFORMER AND PAD BY SERVING UTILITY. COORDINATE WITH SERVING UTILITY, AS REQUIRED, FOR CONSTRUCTION SCHEDULE. COORDINATE CONCRETE BASE AND PAD FOR GENERATOR WITH GENERAL CONTRACTOR PRIOR TO CONDUIT INSTALLATION AND GENERATOR PLACEMENT. REFER TO SI- FFT I=A7AND FLI, ONE -LINE DIAGRAM, FOR CONDUIT AND WIRE REQUIREMENTS. REFER TO DET=3, SHEETEZ0, FOR TYPICAL TRENCHING DETAIL. APPROXIMATE LOCATION OF TELEPHONE TERMINAL BOARD IN MDF 003. COORDINATE PRIOR TO CONDUIT INSTALLATION AND GENERATOR PLACEMENT. PROVIDE (2) 4"CO WITH PULL CORD FOR TELEPHONE SERVICE CABLE. VERIFY EXACT LOCATION OF CONDUIT WITH TELEPHONE COMPANY. CONTRACTOR TO COORDINATE MAIN TELECOM CONNECTION ON NEW POWER POLE FOR ALL REQUIREMENTS. p,N - G ASN/ G cn C) z -o �F FBI4�7 SS/DNAL ENG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 CD (N CD 00 d-) O Zz O= >Q L U cn 0 LL z Oz 0 z_ O N > J > J O N _ 0 z m F_ w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 ELECTRICAL SITE PLAN CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER "Oil E1.00 0.4 0.5 0.6 1.2 1.6 1.9 2.1 2.2 2.5 2.2 2.1 2.0 1.8 1.6 1.2 0.9 0.8 0.6 0.5 0.5 0.2 0.2 0.3 0.3 0.3 0.3 0.4 0.5 0.6 0.6 0.6 0.5 0.5 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.6 0.4 1.2 •1-8 - 2.2 2.5 3.2 3.3 - 3-4 - 3.4.--- - 3-4 - 3.4 3.1 2.6 2.5 2.6 - 23 - -4.9- -1-5 - -4. &- 0.8 0.3 0.3 0.5 0.6 0.6 0.6 0.7 1.0 1.3-- -1--6 - -4.5- 1.4 1.2 - -1-1 - -4.1- -14 - -4.1- 1.2 1.4 1.6 1.5 1.3 1.0 0.7 1.5 3.1 3.8 3.8 4.4 5.0 4.9 4.9 4.9 4.5 4.1 3.4 2.3 3.4 3.2 2.1 1.9 2.8 2.4 1.4 0.8 2.3 2.8 1.7 1.0 1.4 3.0 4.3 3.9 4.3 4.3 2.7 1.6 1.6 1.7 1.6 2.0 3.8 4.7 3.5 2.3 1.6 1.1 0.(, WL1 WL1 F I 0 1.4 3.4 6.2 6.0 5.7 5.6 5.5 5.4 4.0 1.6 2.3 2.8 2.7 5 7.3 11.7 4.7 2.5 9.4 11.2 3 8.8 14.0 8@ 11.2 13.8 3.2 10.9 13.E 6.7 3.7 2.2 1.2 O.f ------- pp °RR1 °RR1 0RE1F7770 0 7.8 0 12.9 14.0 ° 0.6 2.6 .5 SL1 OQ C3 1.8 9.9 12.0 6.7 4.2 1.1 0.� 5.2 5.2 5.5 5.7 5.9 5.9 6.2 6.4 5.5 4.6 4.1 O � Q � 0 � ��� RR1 n 0.8 4.1 3 ° 12.8 10.3 2.1 0.� 7.9 9.2 10.4 11.0 11.0 10.3 9.3 8.0 6.6 5.5 4.7 U C3 MCCt� 1.0 5.5 1.1 5.3 5.1 7.6 8.4 9.3 9.7 9.7 9.2 8.6 7.7 5.8 4.5 -- -- -- -- -- -- -- -- - - - - LJ L 8.9 5.8 1.6 0.: 0.9 4.2 4.0 4.8 6.8 7.2 7.9 8.3 8.3 8.0 7.5 7.0 6.� .3 2.3 1.1 0.4 F i 0.9 3.1 &23.5 4.4 5.6 6.2 6.8 7.3 7.3 7.1 6.7 6.3 2 i 1.3 1.0 0.5 SL1 SL1 - 1 1.0 3.4 3.7 4.8 5.3 5.8 6.3 6.6 6.7 6.5 6.2 5.9 5.7 _�� --i --- 1.8 1.3 0.7 LL o 1.0 3.5 - -- -- - -- -- - - - - - 3.7 4.8 5.3 5.7 6.0 6.1 6.2 6.1 6.0 5.7 5.'3 4.4 3.1 1 1 2.6 1.7 0.8 3= 3. qD 9 3.0 3.9 4.7 5.38 5.7 5.8 5.9 5.9 5.9 .9 5.6 5.1 4.1 3.3 0 o O 3.3 2.0 0.9 l ii rqn 3.8 .9 5.4 5.6 5.7 5.8 5.7 WL1 .0 5.4 0 1.7 4.1 4.6 4.8 - 5.4 5.7 5.8 5.6 .9 4.7 4.1 5.1 5.4 5.7 5.7 5.6 .6 2.9 ALD 4.0 4.6 5.1 5.4 5.5 5.5 5.5 5.5 5 2.2 4.0 4.6 _ 5.1 5.5 5.5 5.4 5.4 5.5 .6 1.8 3.9 4.5 4.9 5.2 5.4 5.4 5.5 5.5 .6 1.3 3.9 4.5 4.7o4.9 5.2 5.5 5.5 5.6 .6 1.7 3.8 4.3 4.5 4.8 5.0 5.3 5.45.5 5 2.1 3.1 3.8 4.3 4.7 4 J 4.7 4.8 5.2 6 2.8 8 4.5 9. oa 0 5.4 1i 1 3.3 ; 12 .5 2. .5 2. - non, Ev .5 2. Li .5 2. - .6 2. 2.2 2.4 2. '2. .2 4.03.9 3.7 c4.5 47 8 4.2 3.9 3.4 - - 4.4.4 ---- MKBUS --- '2 4.8 5.1 Q 5 3 5.6 9 Q 5.0 4.8 4.3 �.9 - - Q I 5.9 s�5 5.3 5.2 sL1 sL1 4.2 4.6 5.0 5.2 55 5.8 1 5.6 5.2 4.7 4.3 3. 6.0 5.8 5.7 15.6 5.8 5.7 5.4 4.7 4. �54 4.3 4.6 5.1 5.6 5.8 5.9 6.0 1 5.3 5.3 5.5 5.6 6.1 6.1 6.1 6.0 �.4 5.3 5.1 4.6 4.4 4.6 5.2 5.7 6.0 6.1 6.1 6.1 6.1 5.9 5.8 5.5 I .5 4.9 5.3 5.5 5.5 5.3 5.6 5.8 7 6.2 6.3 6.3 6.3 6.2 6.2 6.1 5.9 5.7 4.7 4.8 5.0 5.5 6.3 4.9 4.7 4.3 6. Q 0 5.6 5.4 5.1 4.6 4.5 4.8 5.4 5.7 6.0 6.2 6.4 Q C 3.6 4.7 5.4 5.6 5.8 5.8 5.7 5.7 5.7 6.5 6.4 6.3 6.4 6.6 6.5 6.3 6.2 6.3 5.9 6.0 6.2 6.8 7.8 6.1 5.9 5.3 5. 3.8 4.8 5.3 5.6 5.3 4.9 5.3 0 5.0 47 4. .3 ` 0 \\\4. 3 5. � 4.9 4.3� 5 5.5 5.2 4.8 4.� a p- 5.1 5.0 4. 4 T p 5. 4._ � 5.8 5.5 4.8 4. 5.7 3.2 3.8 5.7 6.1 6.1 5.8 5.5 5.5 5.8 5.8 5.5 5.0 4.6 4.6 5.0 5.6 5.7 Q 5.9 6.3 6.7 6.8E�p 6.4 6.6 6.9 6.8 6.5 06.4 6.6 6.9 6.6 ?Q 7.4 II 8.5 6.6 6.3 5.70 sL 1 a -5.$ 5.5 4.9 4.6 4.6 5.1 5.7 5.9 6.2 6.5 6.8 2.6 3.0 �.6 6.5 6.3 5.8 5.4 5.5 5.8� 6.9 6.7 6.7 6.8 7.0 6.9 6.7 6.7 6.8 7.0 6.7 6.9 7.5 8.6 6.7 5.9 5.4Q 4. _ 5.6 5.3 5.0 4.7 4.7 5. 5.8 6.2 6.4 6.6 6.7 sL1 6.2 6.1 15.9 5.6 5.7 5.6 -- --6:U--6.8 6.8- 6.9 6.9 6.9 6.8 6.8 6Y--6-.8-- 6.7 6.7 7.1 6.9 5.1 5.0 4.6 Q 0.2 5.1 5.1 4.h' 4.8 5.2 6 � 5.9 �6.� 4 .5 - 16.4 5.7 5.9 .8 5.6 5.64-� 6.3 6.4 .6 6.6 6.4 6. 6.5 .6 6.2 5.2 4.2 sL1 5.6 5� A 0. � 5.1 5.3 � I d� ' 4.7 � 5.1 1 b 1 5. 5.9 .1 5.8 �(i)6 5.7 �.o 6.0 5.8 05. 5.7 9 5.6 L'&2 L04.4 3.7 v SL1 t 2 4.4 5.1 .3 1 4.9 4.9 4.9 5.1 5.2 5.0 4.8 4.9 2�� 3 :1- t--4-0 � 4.1 __ --- Cn J JJ C J 0 4 PHOTOMETRIC PLAN - SITE & LEVEL 1 I SCALE: 1/8" = 1'-0" NORTH 5.0 2.1 0.8 5.0 1.8 0.7 I 6.5 2.0 I 0.6 L1 E 8.2 2.3 0.5 5.4 2.2 0.6 3.8 2.5 0.7 3.6 2.9 0.8 3.7 3.2 1.0 4.6 4.0 1.4 z)7.2 5.9 1.7 WL1 E 7.2 6.2 1.9 6.5 5.9 2.9 6.0 5.5 2.9 5.7 5.2 2.7 5.7 5.2 3.7 6.1 5.3 3.6 WL1 05.4 4.9 3.3 3.1 3.8 3.4 1.9 2.6 1.9 1.2 1.4 1.4 p,N • G A Sys � cP Z �F FBI SS/DNAL ENG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.dcengineering.net Phone:208.288.2181 Project:21 AMA01 04 00 a) O 0 � Zz O= Q 0 � L U cn LL z O0 z 0 a� > J co J O C) O N - 0 o Z m F- w Z N C/) Q LU a LU 04 U REVISIO N DATE REASON FOR ISSUE PHOTOMETRIC PLAN - SITE & LEVEL 1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 N Cn P ACP SN/yam ri I o Z N M -11 A SS/DNAL LNG 04/13/22 1 2 3 4 5 6 7 8 9 10 12 13 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 I I I I I I I I I I I I ^ J ©ANKROM MOISAN ARCHITECTS, INC. MAINT. � 000s 2.4 .5 12.8 3.5 4. 4.4 3.8 3.2 2.p 3.0 3.6 4.2 4. ,_.9 3.2 2.9 3.0 3.6 4.3 4.5 3.9 3.3 3.0 3.1 y3 4.2 4.3 3.7 2. srol� 0 - 3.3 .2 3.6 4.7 5. 5.8 5.1 4.0 3.6 4.6 5.6 5. 5.1 4.0 3.4 3.7 4.7 5.7 5.9 5.3 4.2 3 6 3.9 5.6 .6 4.9 3. 0007 DC ENGINEERING 4.7 �.3 4.5 5.8 6.1 6.0 6. 4.7 4.2 5.6 6.000 '.0 4.7 3.8 4.2 5.6 6.2 6.2 6.4 5.1 43 4.6 6.1 0 5).9 5.9 4.3 2.9 Careful listening. Dynamic solutions. isteniisteniengineering.net Phone:208.288.2181 Project:21 AMA01 .6 6.2 5.3 14.9 5.6 6.2 6.2 5.8 4.5 3.' 4.0 5.2 6.0 6.1 5.7 4.5 3.7 4.1 5.3 6.2 6.4 6.3 5.3 4.6 4.9 5.8 6.3 6.2 5.7 4.2 0 = .1 5.5 6.6 .5 6.6 5.6 4.7 4.8 5.4 5.5 4.7 3.8 3.3 3.5 4.2 5.1 5.4 4.6 3.8 3.3 3.6 4.4 5.5 5.9 5.6 5.2 5.1 5.2 5.4 5.8 5.7 4.9 4.0 3.5 3.4 3.3 3.1 .9 5.0 6.3 6.9 6.3 5.1 4.3 4.2 4.5 4.5 3.9 3.3 3.0 3.1 3.6 4.2 4.3 3.9 3.3 3.1 3.2 3.9 4.7 5.2 5.5 5.9 6.4 6.3 `5.6 5.2 4.9 4.5 4.2 4.3 4.8 4.9 47 .6 4.5 5.8 6.4 5.8 4.8 4.2 4.2 4.6 4.7 4.1 3.4 3.1 3.2 3.7 4.3 4.5 4.0 3.4 3.1 3.3 4.0 4.9 5.7 6.4 7.4 7.6 7.1 6.6 5.7 5.3 5.2 5.2 5.7 6.1 6.0 .8 7 -E%��6� 6.2 5.i 5.'r - 5. -5�56 4.0- -''. - -3.7 .� � -5� �.0- 3. 3.8 4.8 - T7 2- 9 -7.6 6 6.6-Ei.�6.6�5- .9 -6.6O I � � � � I t o I .0 5.3 6.5 6.8 6.8 5.9 5.3 6.1 6.5 0 6.4 6.1 4.8 4.2 5 6.1 6.2 6. 4.7 .9 4.3 5.� 6. ® VESTIBULE 7.1 7.0 6.9 7.2 SL1 E 0 SL1 �1 01 sL1 .8 5.2 6.3 6.5 6.7 5.9 5.4 6.2 6.6 4.3 56 6.1 6.1 6.0 4.7 3.9 4.3 5.6 6. �6. 5.3 5.9 6.2 6.6 5.7 5.2 4.8 .1 .3 4.4 5.7 6.3 5.9 5.0 14.7 5.3 6.2 6.3 5.5 4.3 3.16 3.7 45 5.5 5.7 5.0 3.9 3.4 3.6 4.6 5.6 4.0 5.0 5.3 4.8 1 4.1 3.8 3.4 9- 8 -4r9- 5.5 -5.0 49 -4.0 .5- 54 -5t6 4.9 3 _ _ _ _ - 95 -3r1 3.3 3 _ 91 CORRIDOR F 7 0001 L --Z-.2- 4.8 6.9 7.1 5.4 4.2 4.2 5.2 6.18 7.0 5.5 3. O LAUNDRY s 1 0004 BOILER / - LAUNDRY 3.8 6.6 9.1 9.3 7.3 5.0 4.8 6.6 8. 8.5 7.1 4. 0 0004 ELECTRICAL 0002 C= - - 0005 - - - ii- - - - - - - - - - - - - c0 3.9 6.7 8.2 8.4 7.5 5.2 5.0 6.8 7.0 7.6 7.3 4. N MDF O 00 d� 3.1 4.8 6.4 6.7 5.4I 4.3 4.4 5.5 6.7 7.0 5.9 4A z 0 3.0 3.9 3.4 3 2 3.13 I--- Z CD 4.2 3.8 3.5 3.7 4.5 5.5 5.7 5.1 4. z Q = 5.3 5.9 5.3 4 7 4.8 5.2 5.4 5.1 4.8 4.7 4.7 4.4 3.8 3.1 Q 3.01 3.2 3.7 4.6 5. 6.1 5.6 5. < 7.9 7.7 7.0 3 6. 6.4 6.1 5.9 5.8 5.7 5.2 4.6 4.0 3. L U C 2.7 3.3 4.3 5.9 7. _ _ _ _ L,L z - I - - - - - I I 0 I �- - - - I I-�tR-�2 -- - H O 8.9 7.6 7.0 7.0 6.9 6.3 6.4 6.2 5.5 1E 4.2 3. 1o3s Q 2 2. 5.4 5.7 7.0 =7.6 7.6 7.5 0 - - - 8. --g-.6 T.2---- 6-.46-.14 6.6--6.-a �� 15-.6 5.0 4.3 3. - - - - -I - - - - - J z_ 4.8 7.1 A) 8.0 7. 6.0 6.0 7.3 7.6 7.7 7.6 6.8 Q A 0 j M s 1 6.4 6.7 6.1 5.5 5.6 6.1 6.3 5.9 5.6 5.4 5.4 5.2 4.4 3.4 K Q -0 0 r46.F 7.7 --7�8 6.8 6.0 o I� z co 6.2 6.5 6.0 5.4 5.5 6.0 6.2 5.9 5.5 5.4 5.4 5.2 4.4 3. ~ o u 3.1 6.3 8.3 8.6 7. 5.8 5.6 6.4 .5 7.6 6.6 6.0 Z Q w Q cal U a 7.6 7.8 7.0 6.2 6.12 6.6 6.6 6.3 5.9 5.8 5.6 5.1 4.4 3. 8.4 8.6 0 7.5 6. 5.13 W9 7 7.8 7.4 07.1 MECH SL1 E 8.9 d.0 7.6 .0 7.0 6.9 E 6.3 .4 6.2 5.6 �.8 4.2 3.E RENISIO DATE REASON FOR ISSUE 0009 8 9 EL 1 7.�i 6.1 1 5. 7P 7.4 7.8 7.7 1 8.4 7. 7.3 .7 6.6 6.7 6. 6.1 .1 5.9 5.4 4.7 4.1 3. 7.6 7.5 6.5 5.3 5. 6.1 6 3 7.0 6.7 6.5 I I I I I I I 0 .�6. �6.0� .4 5.'� -8�. �5 5.0 4.6 4.0 3. I I I I I I I I I cli co co E PHOTOMETRIC > PLAN - LEVEL P1 U w J W PHOTOMETRIC PLAN - LEVEL P1 o SCALE: 1/8" = 1'-0" CONSTRUCTION in U) NORTH SET c 0 E w 0 N DATE PROJECT NUMBER N 03/14/2022 184470 ry 6 a. U 0 U 91 Schedule Symbol Label QTY Catalog Number Description Lamp Number Lumens LLF Wattage Lamps per Lamp O B 1 6 JSF 151N 18LM 30K 15" Round Edgelit (Slimform) Surface N/A 1 1813 1 30.2 90CRI MVOLT ZT WH Mount, 3000K, 90CRI, MV ❑ 1 N/A 1 1490 1 30 SM1 OHO F-1 B2 3 N/A 1 750 1 6 1 E M U) U) CU .0 J 1.11 Statistics Description Symbol Avg Max Min Max/Min Avg/Min Corridor + 25.0 fc 29.7 fc 18.5 fc 1.6:1 1.4:1 TYP CORRIDOR PHOTOMETRIC PLAN - LEVEL 3 SCALE:1/8" = V-0" Schedule Symbol Label QTY Catalog Number Description Lamp Number Lumens LLF Wattage Lamps per Lamp 6 JSBC 71N 30K Juno SlimBasics 7" 3000K 90CRI 1 1128 1 17.2 OUA 3 JSF 131N 18LM 30K 13" Round Edgelit (Slimform) Surface N/A 1 1813 1 20.2 O U B 90CRI 120 FRPC WH Mount, 3000K, 90CRI, 120V U C 3 UCEL 121N 30K 90CRI 12" UCEL 120V LED UNDER CABINET 1 388 0.97 4 � 3000K 90CRI 100W equivalent, Al screw base Lamp, SSC base up Serial 1 1179 1 35.4 1 A19-100W-P1-30K-E26- 0 0 o UD U1 with white opaque dome lens covering LED Number:PL13057-001 array. Rated 5.5 watt dimmable, 3000K CCT 1 FMMCL 840 S1 7" LED CLOSET LIGHT LED 1 593 1 10.64 o UE Statistics Description Symbol Avg Max Min Max/Min Avg/Min Bathroom + 21.4 fc 44.0 fc 3.3 fc 13.3:1 6.5:1 Bedroom + 15.1 fc 23.0 fc 6.5 fc 3.5:1 2.3:1 Closet + 7.5 fc 8.3 fc 6.9 fc 1.2:1 1.1:1 Living/Kitchen I + 21.4 fc 54.4 fc 7.7 fc 1 7.1:1 2.8:1 Schedule Symbol Label QTY Catalog Number Description Lamp Number Lamps Lumens per Lamp LLF Wattage O B 1 2 JSF 151N 18LM 30K 15" Round Edgelit (Slimform) Surface N/A 1 1813 1 30.2 90CRI MVOLT ZT WH Mount, 3000K, 90CRI, MV ❑ 1 N/A 1 1490 1 30 o SM1 O O Statistics Description Symbol Avg Max Min Max/Min Avg/Min Corridor + 9.0 fc 18.3 fc 4.7 fc 3.9:1 1.9:1 �I a � �i • L`I ■■1■Tr�_ _`_■�_ �il�i�Y�i�i�1��i�i�il���YI�' - �R��Yf�i■i��i������ipl�■ :, . _ ram® J �,:, f� lam I.,1■■ 7 TYP CORRIDOR EMERGENCY PHOTOMETRIC PLAN - LEVEL 3 L SCALE:1/8" = V-0" +7.3 +7.9 +8.7 +9.4 +10.0 +10.3 +10.4 +10.0 +9.4 +8.7 +7.9 +7.1 + + + + + + + + + + + + 8.1 9.0 10.0 11.1 12.0 12.5 12.5 12.0 11.2 10.1 9.0 7.9 + +11.5 +13.0 +14.3 +15.1 +15.1 +14.5 +13.2 +11. +10.2 *8.8 + 9.8 +1 .3 +13.1 +15.1 +16.7 +17.8 +17.9 17.0 +15.3 +13. +11.4 +9.7 + + + + + + + + + + + + 10.5 1 14.5 16.9 18.9 20.1 20.2 19.2 17.2 14. 12.5 10.5 11.1 *13. +15.5 +18.1 +20.4 1.8 .7 +18.6 +15. +13.3 +11.1 + Ull 11.5 +1 .6 +16.1 +18.8 +21.1 +22.6 +22.7 21.5 +19.3 +16. +13.9 +11.6 + 11.7 +1 .8 16.3 +18.9 +21.2 +22.6 +22.7 21.5 +19.4 +16. +14.1 +11.9 + 16.3 18.8 21.0 22.3 22.5 21.3 +19.2 +16.7 +14 12.0 + �11.8 +130 +16.3 +18.8 +21.0 +22.3 +22.4 +21.3 +19.2 +16 +14.2 +12.0 + +11.8 +13.9 +16.4 +19.0 +21.2 +22.6 +22.7 +21.6 +19.5 + 6. +14.1 +11.9 + +11.7 +13.9 +16.4 +19.1 +21.4 +22.9 +23.0 +21.9 +19.7 +11.5 +13.6 +16.2 +18.9 +21.2 + 2.7U9 B1.8 +19.7 +17. + + 6.9 7: +11.0 +13.0 +15.5 +18.0 +20.3 +21.7 +21.9 +20. 18.9 +16. +7.4 +8.; +10.5 +12.2 4.4 +16.6 .6 +19.8 +20.0 +19.2 7.5 +15.4 I .1 C i/�Z l.+8: +9.7 +11.2 3.0 +14.8 +16.4 17.4 +17.6 +16.9 +15.5 3. + + 7.6 7.1 +9.0 +10.2 11.5 +12.9 +14.1 +1 .8 +14.9 +14.4 +13.4 +12. a a +35.2 +37.0 11 34.9 +30.9 r26.2 +19.7 15.6 13.1 11. 32.6 26.9 21 L +22 33.4 27.5 +22 32.6 27.3 6 +17.4 U14.412+ 4+18.4+ 8 +19.0 +16.0 +13.5+ • + + • + 6.5 +14.0 + +14.3 +23.5 25.5 +23.0 +20.1 17.1 +14.3 + +15.1 +19.7 +22.6 +22.9 +21.0 7.9 +14.5 + +17.0 19.4 +(�2,.L55 Ij+22.0 +21.5 +17.0 +19. +20.9 2A+20.8 +3.3 + +7.7 +8.6 +9.4 +10.2 +10.7 +10.8 +10.5 +9.8 + .8 +8.5 +9.7 +11.0 +12.1 +12.9 +13.1 +12.6 +11.5 + 0.2 +10.2 +12.1 +14.4 +16.11 +18. +17.3 +15.4 13.1 +11.1 + +10.7 +12.9 +15.5 +17. +Q rj18.9 16.7 14.1 11.8 + 10.9 13.1 +15.8 +18. 0. +�19.3 +17.1 14.5 +12.1 + +10.7 +12.8 +15.2 + 17. +19.2 +1 +18.6 +16.6 14.3 + +12.0 1 +10.3 +12.1 +14.1 +16.2 +17.5 +17.9 +17.1 +15.6 13.7 +11.8 + +9.8 +11.3 +12.9 +14.5 +15.7 +16.0 +15.6 +14.5 13.1 11.6 10. + 9.3 + 10.6 + 12.0 + + 13.4 14.3 + 14.7 + 14.6 + 14.0 + 13.0 + 11.7 + 10. + 9.0 + 10.1 + 11.5 + + 12.8 13.8 + 14.3 + 14.5 + 14.1 + 13.4 + 12.4 + 11. + 8.9 + 10.0 + 11.4 + + 12.9 13.9 + 14.8 + 15.3 + 15.3 + 14.7 + 13.7 + 12. +9.0 +10.1 +11.8 +13. + + .2 +17.0 +17.3 +16.9 +15.9 +1 + 9.3 + 10.6 + 13.0 + 14. + 16. 19.6 20.2 1 9.6 +11.6 +14.4 +1❑++22.8 1--+20 +23.6 +2. +21.99.9 ++13.0 +16.1 +14 +21.26.1 27 +2PJ2 -95.4 +18.2 +20. ❑+23.+29.6 +31.4 +3 . 30. +2 . + +20.5 +23. ❑+26.3 + + + + + +20.7 +23.0 +25.7 +29.0 +32.5 +36.2 b2, +4 .8 +41t, 23.4 25.7 28.4 31.5 35.0 38.4 42.1 4 r.5 51.1 +18.1 +20.3 +23.2 +25.6 +28.0 +30.7 +33.7 +36.8 +39.6 +42.0 +43.6 +42.7 + +19.6 +22.2 +24.8 +27.1 +29.5 +32.1 +35.1 /y+^,�38.0 +40.7 +�/422..3 +42.2 +39.5 + +19.6�2W.P*26.8 +29.3 +32:0_3p" 38.3 +42.1 'A5.A 44.3 +18.7 +21.0 +2 .2 +23.3 +18 0 26.4 +31.3 +37 + + + + +16.2 +18.0 +18. +13.9 +11 8 +23.6 +26.8 +32. +41. + +5 .4 +49.1 + r4 TYP UNIT PHOTOMETRIC PLAN %J SCALE: 1/4" = 1'-0' PN - G M , ASy� P -II A SS/ONAL LNG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 Q0 (N CD 00 d-) O Z z O= W Cn ID LL z O0 z O > J > J _� O -0 J z m F_ W o Z o U c) LU N U a REVISIO N DATE REASON FOR ISSUE TYP. CORRIDOR & UNIT PHOTOMETRIC PLANS CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 El SHEET NUMBER "011 c c c E M J JJ C J 0 E T2 3 4 5 6 7 8 9 10 12 13 4 ELECTRICAL LIGHTING PLAN - LEVEL P1 SCALE: 1/8" = 1'-0" NORTH GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET Pi nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET F5 0ri. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. KEYED NOTES G) 1 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 2 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH # CMR-PDT-10 OR APPROVED EQUAL. 3 MOUNT FIXTURE AT T-6" ABOVE LANDING. 'G WASy O O Z /9 RF�isTERE° ss/DNAL ENO' 05/19/23 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) O o P- Zz O= >Q L U cn 0 LL z Oz 0 z_ O N > J > J O N _ 0 z m F_ w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 05/19/23 CCD 007 ELECTRICAL LIGHTING PLAN - LEVEL P1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEETNUMBEIR "Oil E2.00 1 2 3 4 5 6 I I I I I I ELS-12 os 1 1 L-2 RISER ROOM 1034 WL1 1 L-5 �LI � �U ELS-10 EX1 SL1 1 039 1 � I I ELS 4 SL1 ELSAft WH - I I ELS-8 O4 S1 ELS-8 _ — WL1 O4 71 S1 LS-12 1 L-3 O p ELS-4� EX1 SL1 TBT I I I I z T 8 FI #382: Level 1 Lighting Quantities and Layout T 10 12 FI #55: Lighting Clarification 13 1 0 WR F �1 39� _ _ •® _ _ •® �_� ��� tME 0 0 0 0 0 �,- RFI 413 �i� �p I pv FpDl 1] - 1 L-14 L-14 ��rPD 5 • 1 L-16 • *EL B2 1 PD2 O D7 0 (1) PD8 -28 1L-16 0 ❑ 1 L�- 6 DAYLIGHT ZONE (2) PD9 O (1) PD10 J B2 0 0 0 ELS-28 1 L-14 ELS-28 1 L-14 ELS-28 E 1 #\ / I& -16 D 1 L-16 1 L-1 o O DAYLIGHT ZONE 0 0 0 PD1 1 L-14 c O - 1 L-16 ELS-28 ELS 28 1 L-16 B2 1 L-14 c 1 L-14 B2 ELS 8 0 4. PD 22 @3 C B2 ELS-28 • o E 1 L-4 ELS-28 1 L-14 1 L-14 B2 C> 1 L-14 1 L-14 Q Q 0 n 1 FEST. 1 L-14 0 1 L-14 O BISTRO 00 I GREAT ROC. 1 L-14 0 1-1 10021- L- 6 -16 1 -1 L- 6 1900 EX1 1001 QZ-ELS-301-12 ELS-28 1 L-4 ELS-10 1L-14 RFI-055 0♦ 1L-14 # RR FAMILY-ROELS-28 1 L-14 ELS-28 1L-14 1006 _ 14C38 1 U2 0 ES-6 E S-6 E S-6 E S-6 1L-14 B2 V1 BEVERAGEST T N S 3 EL0 # C 1 L-12 O GL1 3SO 1 L-14 ELS-28 1 L-14 1 L-14 ELS-28 2 - OS I I I -14 1 L-14 ® O O ELS-30 LE I 5 L -L - PD13 O O O EX DDISCOVERY% EX1 p PD3 ELS-10 CONF. MAIL ELS-10 KIT N ELEV. WAITING RECEPTION B2ELS-30 1 L 14 1020A 1 L-14 L-12 O PD 14 ELS-28 1 L-14 1 L014 1 L 14 1 L-12 GL2 1 L-14 O PD4 ELS-28 ELS-28 22 OS OS O O� E S- 6 E S- 6 E S- 6 BUSINESS( FF CE G ELS-28 3 PD14 1 7 1L-1 O PD4 D R. R w be B2 L-1 1L14 -6 ES-6 • , B2 - 2 ELS 30 1 L-14 ELS-28 ;,- E -S-2 6 L2ElMGR 1 L- L-1 so 1 L- 2 LS-12 103 L C> 1 1co G2 — 1 L-4 B2 1 1 L_ 12 1 _ RR - — — ELS-30 L2 L2 B2 0 1 2 1 L-1co co 1 ELS-28 RECEIVING R�3 CORR 101 G 2 E 6 F. ELS-28 " 2 020 2 101 1 GL GL2 1 L-12 CORRIDO TRASH 1016 ADMIN z 1021 24 1 L-4 1 1 L� _12 1015 G 2 1 L-12 pir r----- LEL -28 1 L-4 G 2 LT_ 2 1L-4Cf. EMP OYk O CP 1 101_ S4 1P- - - 1-120 � L' GL2 �2rZ1025 P 1 L-4 EL -28 TRASH COLLECTIO PARKING GARAGE 1030 RAMP 0 104 1 f " 1 L-4 1 L- 1 L-3O LS-4 • 1 L-3 O ELS-4 • SL1 0 SL1 WL1 L ------ - ----- r------- LS-6 ELS, i S1 i S1 i I I I I L 13 I ELS-4 • I I I I I I 1 L-2 0 S4 O O EL MECHANIC L SL 1032 1 L-3 0 0 0 O I 4 ELECTRICAL LIGHTING PLAN - LEVEL 1 I SCALE: 1/8" = 1'-0" r JO L I_ co Cn Cn J JJ C J 0 1 L-3 O 0 i EX1 ELS-4 • 1 L-3 0 fD SL1 ELS-10 I O 1 L-3 ELS-4 e O S L 1 1 L-3 0 0 0 0 0 0 0 I I S4 GENERATOR -1-031- - - 1 L-3 O 1 L-2 ELS-4 sL1 I 1 L-3 SL1 NORTH GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET F� nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET F5 nC. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. KEYED NOTES O 1 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 2 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #CMR-PDT-10 OR APPROVED EQUAL. 3 PROVIDE AND INSTALL CEILING MOUNTED, 2-RELAY OCCUPANCY SENSOR, SENSOR SWITCH #CMR-PDT-10-2P OR APPROVED EQUAL. 4 MOUNT FIXTURE AT 7'-6" ABOVE LANDING. 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.dcengineering.net Phone:208.288.2181 Project:21 AMA01 (D CN 00 co z O o P Z z O1 >Q LJJ (6 LL z O0 z O N > J � J _0 � O N _ o O z m W � z N � Q Q VLU C%4 U REVISIO N DATE REASON FOR ISSUE 1 6/18/21 Addendum #1 2 12/23/21 Plan Check Response 4 1/03/22 Addendum #03 06/27/22 RFI-055 ELECTRICAL LIGHTING PLAN — LEVEL 1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2.01 1 2 3 4 5 6 7 8 9 10 12 13 1 LLLL I KlI SCALE: 1/8" = 1'-0" E M U) U) C CU J .0 C J E n0 n� SEE SH_ETS F2. .-F2.._1 FOR ELNARGED UNIT PLANS. SEE SH =FT�E2 : -F2 ?1 FOR ELNARGED UNIT PLANS. NORTH GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET Pi nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET F5 nr. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. KEYED NOTES O 1 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH # CMR-PDT-10 OR APPROVED EQUAL. 2 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 3 MOUNT FIXTURE AT T-6" ABOVE LANDING. PN A. G ASN/ c 'L �O C) z f A �FSRF�ISTERE�G����� S/DNAL EN 01/06/23 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) O o P- Zz O= >Q L U cn 0 LL z Oz 0 z_ O N > J > J O C) _ 0 z m F_ w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 12/30/22 CCD 003 ELECTRICAL LIGHTING PLAN — LEVEL 2 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2.02?711 1 2 3 4 5 4 ELECTRICAL LIGHTING PLAN - LEVEL 3 SCALE: 1/8" = V-0" R r JO L I_ M U) U) CU J .0 C J 0 n 6 7 8 9 10 12 SEE SH _FT 222 -F2 >-1 FOR M NIARr_Gn I INIT PI ANIQ SEE SHLEISFF9 2T-F2 '?1 FOR ELNARGED UNIT PLANS. 13 NORTH D GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET F'a nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET Fri nr. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. KEYED NOTES O 1 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 2 PROVIDE AND INSTALL CEILING MOUNTED, 2-RELAY OCCUPANCY SENSOR, SENSOR SWITCH #CMR-PDT-10-2P OR APPROVED EQUAL. 3 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH # CMR-PDT-10 OR APPROVED EQUAL. 4 MOUNT FIXTURE AT T-6" ABOVE LANDING. p,N - G ASN/ � cP -II A ,cF FGI SS/ONAL LNG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) O o P- Zz O = >Q W cn LL z O0 0 z O N > J > J O N _ 0 z m F_ w o Z oN U ~ Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 ELECTRICAL LIGHTING PLAN - LEVEL 3 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER "M11 E2.03 1 2 3 4 5 6 7 8 9 10 12 13 I I I I I I I I I I I I I I I I I I I I I I SEE SH=FTS F22(-F2 ?1 FOR ELNARGED UNIT PLANS. , 701 [1177 - ---------- , I , =' 0 I. ,_. , Fi� El El �Y a. 0 6L-2 - - _ S U C> C> C> # RI R C> - - U EL - - - - • - - B1 - - 10 - O - X1 M21 _ S - STOR. , 4005 S4 , r L- 6 8 - � _ _ ® I T t IDF 4006 L-8 0 =: LS 16 .. ,-- 1 I ' W b2l - L-2 O r7777=771 -LEL I �] 0 -, ." rt; L-2 I 3 L- O I O S1 S1 ELS-8 I I =7 I � I SM1 O _® L 'ELS-16 EX1 I ffxi EL -10 - 0j.-I I I0. • I — 6L-8 I ■■■ I i! 6L-2 @6L-2 @6L-2 T- ~ — o .,,; jN■� pmlq 1� • C m •®�q - ■ KENMORE �1■ �. rI , iUsEMO �■ ■ ICI ■I 1MOM No Il - ima EN: -- Ifww.I■■I■■■■MMMM■■1 ■■■■■■■ ■■■■�■■■��--'�'�■�■■■�■■■■■■■� MEN s - f�0 �MIMEf fEms �MIMEI EEL: NEW 0 1 � f 1 LLLU I KID SCALE: 1/8" = 1'-0" E M U) U) co J .0 C J E n0 I \ SEE SH =FTS F2 r--F2 ?1 FOR ELNARGED UNIT PLANS. I I GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET F'l nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET F5 nr. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. # KEYED NOTES O 1 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 2 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH # CMR-PDT-10 OR APPROVED EQUAL. 3 MOUNT FIXTURE AT T-6" ABOVE LANDING. p,N ' G ASN/ � cP C) z -II A ,cF FGI SS/DNAL LNG 04/13/22 38 NORTHWEST DAVIS SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. OC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD 00 d-) O Z z O= � a LU o LL z O0 z O >� J > J O � o N _ 0 � z m W z o U LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 ELECTRICAL LIGHTING PLAN — LEVEL 4 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2. 1 2 3 4 5 6 7 8 9 10 12 SEE SH 1 FOR ELNARGED UNIT PLANS. i SEE SH F2_ _1 FOR ELNARGED UNIT PLANS. 1 ELECTRICAL LIGHTING PLAN - LEVEL 5 SCALE: 1/8" = V-0" co NORTH R r JO L E M U) U) CU J .0 C J 0 n GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET Pi nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET F5 nr. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. KEYED NOTES O 1 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 2 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH # CMR-PDT-10 OR APPROVED EQUAL. 3 PROVIDE AND INSTALL CEILING MOUNTED, 2-RELAY OCCUPANCY SENSOR, SENSOR SWITCH #CMR-PDT-10-2P OR APPROVED EQUAL. 4 MOUNT FIXTURE AT T-6" ABOVE LANDING. p,N - G ASN/ � cP -II A SS/DNAL LNG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N CD 00 z O 0 � Zz Q 0 � LU cn 0 LL z O 0 >w. 0 z O > J > J O N _ 0 z m w z o U Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 ELECTRICAL LIGHTING PLAN - LEVEL 5 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2 4 ELECTRICAL LIGHTING PLAN - LEVEL 6 SCALE: 1/8" = 1'-0" R r JO L E M U) U) CU J .0 C J 0 n 5 T 6 T 7 8 SEE SH-_ET C-F2_21 FOR ELNARGED UNIT PLANS. SEE SH =FTS F2 i -F2 '?1 FOR ELNARGED UNIT PLANS. 9 C 0 12 13 rtl4`1. L L L ` r 721. NORTH GENERAL LIGHTING NOTES 1. NUMBER ADJACENT TO DEVICE OR HOMERUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. CONTRACTOR SHALL COORDINATE ELECTRICAL SYSTEMS INSTALLATION TO AVOID INTERFERENCE WITH DUCTWORK/PIPING AND OTHER TRADES. CONTRACTOR SHALL COORDINATE PLACEMENT OF FIXTURES WITH ARCHITECTURAL REFELECTED CEILING PLAN. LOCATION OF FIXTURES SHALL GOVERN WITH CONFLICTS WITH SUPPLY/EXHAUST DIFFUSERS. 3. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR CEILING TYPES. 4. ALL FIXTURES WITHIN A GIVEN ROOM/AREA ARE THE SAME TYPE AS THE SINGLE FIXTURE CALLED OUT WITHIN THAT ROOM/AREA, UNLESS OTHERWISE NOTED. 5. LINEWORK SHOWN FOR CLARITY OF SWITCHING ONLY. PROVIDE QUANTITY OF CONDUCTORS AS REQUIRED FOR CONTROL. 6. CONTRACTOR SHALL PROVIDE #10 AWG CONDUCTORS FOR ALL CIRCUITS OF 100'-0" OR MORE UNLESS SHOWN LARGER. 7. REFER TO SHEET F'l nn FOR LUMINAIRE SCHEDULE. 8. ALL PARKING AND COMMON AREA LIGHTING TO BE ROUTED VIA LIGHTING CONTROL PANEL. SEE SHEET F.Fi nr. 9. EMEGENCY/EGRESS LIGHTING IS BACKED UP BY EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. KEYED NOTES O 1 PROVIDE AND INSTALL CEILING MOUNTED, 2-RELAY OCCUPANCY SENSOR, SENSOR SWITCH #CMR-PDT-10-2P OR APPROVED EQUAL. 2 FURNISH AND INSTALL WALL -MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH #WSX-PDT OR APPROVED EQUAL. 3 PROVIDE AND INSTALL CEILING MOUNTED OCCUPANCY SENSOR, SENSOR SWITCH # CMR-PDT-10 OR APPROVED EQUAL. 4 MOUNT FIXTURE AT T-6" ABOVE LANDING. 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) O o P- Zz O = Q W o LL zz O J Q z O > J > J O O N 0 � z m F_ w o oN U ~ Z Q � Q LU N U a REVISIO N DATE REASON FOR ISSUE 2 12/23/21 Plan Check Response 4 1/03/22 Addendum #03 06/27/22 RFI-055 ELECTRICAL LIGHTING PLAN - LEVEL 6 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2 c 1 2 3 4 4 ELECTRICAL POWER PLAN - LEVEL P1 SCALE: 1/8" = V-0" 5 6 7 8 9 10 12 13 NORTH F Note: 15of conduit length that does not have to be encased in concrete. Note: 'MDP2' = 160" wide 'MDP1' = 170" wide GENERAL POWER NOTES 1. NUMBER ADJACENT TO DEVICE OR HOME RUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEE 1;HFFT F`I nr-='� n1 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. KEYED NOTES O 1 CONNECT DOUBLE ELECTRICAL VEHICLE CHARGER PER MANUFACTURER'S RECOMMENDATIONS. PROVIDE AND INSTALL JUNCTION BOX ON WALL AT +48" AFF WITH 1 "C, 3#8, 1#8G FROM PANEL INDICATED. 2 PROVIDE AND INSTALL JUNCTION BOX ON WALL AT +48" AFF FOR FUTURE ELECTRIC VEHICLE CHARGER. PROVIDE AND INSTALL 1".C, WITH PULL CORD FROM PANEL PP. PROVIDE rn\LER PLATE AND LABEL "FUTURE ELECTRICAL CAR CHARGER" 3 INDOOR UNIT IS POWERED FROM THE OUTDOOR UNIT. COORDINATE WITH MECHANICAL FOR REQUIREMENTS. 4 PROVIDE 30W PER FOOT HEAT TRACE. COORDINATE WITH MECHANICAL FOR DETAILS. • G WASy �o o� /STER�� SS/DNAL ENG 05/19/23 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 Z O o P— Zz 0 = Q C) L U v6 0 LL z 0 z 0 Z_ 0 N > J > J _ O N 0 z m F- o w Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 07/13/22 RF1085 AS1004 08/24/22 09/07/22 RF1125 03/09/23 AS1007 05/19/23 CCD 007 ELECTRICAL POWER PLAN — LEVEL P1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER �111 E2.1 0 c i r JO L I_ co Cn Cn J JJ C J 0 i= 1 2 3 4 I I I I 1 LLLU I KID SCALE: 1/8" = V-0" I I I 5 6 7 8 I I I I I I I I I I F'AKYKINU UAKAUL 1039 9 10 12 13 GENERAL POWER NOTES 1. NUMBER ADJACENT TO DEVICE OR HOME RUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEE gHFFT F i nr-F:i 01 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. 0 a KEYED NOTESAU 71 F7 7 7 7171[l # 7 11 FAN IS POWERED AND CONTROLLED BY THE ROOM TELIGHTING. P1-4 oe e� 2 FIRE SMOKE DAMPER, ROUTE CIRCUIT THROUGH J-BOX IN k _ ROOM 1018 FOR FIRE ALARM CONNECTION. ASI 007 � 3 PROVIDE AND INSTALL KNOX SHUT -DOWN SWITCH IN ASI 007 LOCKABLE ENCLOSURE FOR BUILDING SHUNT SHUTDOWN. ICJ COORDINATE EXACT LOCATION WITH AUTHORITIES. 4 ELECTRICAL CONTRACTOR TO COORDINATE ALL REQUIREMENTS FOR AUXILLIARY GENERATOR EQUIPMENT, DINING WITHIN THIS ROOM, WITH THE GENERATOR SHOP DRAWINGS AND PROVIDE AND INSTALL ALL BOXES, FC 1007 FC 1 DEVICES, CONDUIT AND CONDUCTORS, AS REQUIRED. P 25 Q 1C 1D _______ ASI-001.1 PARKING GARAGE RAMP 1040 0 m ASI 004 CL -- — — --— S 1 1111111111111111111111111111111 IT1 P-22 ' K1-38,40,42 1 P-7,9,11 3/4"C-3#10,1 #10G I 1 P-36� �I C 0 ACI r)rld QASI-001.1 GENERATOR NORTH 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.dcengineering.net Phone:208.288.2181 Project:21 AMA01 CV 00 M O 0 � Z z O1 Q W cn 0 LL z O0 �� z O > J co J O p N _0 F_ O Z m W � Z N � Q LU 04 U a REVISIO N DATE REASON FOR ISSUE 5 03/14/22 Construction Set 07/01 /22 AS 1 001.1 08/24/22 ASI 004 09/07/22 RFI-125 03/09/23 ASI 007 ELECTRICAL POWER PLAN — LEVEL 1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 c c 2 3 4 5 6 7 8 I I I I I I I SEE SHEETS / FOR ENLARGED UNIT PLANS oi ELECTRICAL POWER PLAN - LEVEL 2 SCALE: 1/8" = 1'-0" 0 3P-1,,3--II,TR AS 1004 (i u 0 3P-15 AS1004 6 CCD 003 SEE SHEETS E2.20 AND E27 FOR ENLARGED UNIT PLANS 12 3P-1 F TR 1 004 Q6 5 4 NORTH O GENERAL POWER NOTES 1. NUMBER ADJACENT TO DEVICE OR HOME RUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEE!SHFPT'F3 (1(i�k3 01 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. KEYED NOTES O 1 MOUNT RECEPTACLE 6" BELOW COUNTER TOP. 2 SURFACE MOUNTED WATERPROOF RECEPTACLE. MOUNT 6" BELOW CANOPY ROOF. 3 WEATHERPROOF KEYED SWITCH WITH STRING LIGHTS LABEL. Q4 WEATHERPROOF KEYED SWITCH WITH LABEL FOR CCD 003 CORRESPONDING LABEL ON HEATER. 5 PROVIDE AND INSTALL 1/2" CONDUIT WITH PULLCORD TO FACP, AS REQUIRED, FOR SMOKE CONTROL LOUVER. COORDINATE SPECIFIC REQUIREMENTS WITH FIRE ALARM Q6 CONTRACTOR. CONTROL WIRING BY OTHERS. 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD 00 d) O Zz O = Q 0 W cn 0 LL z Oz 0 z_ O N > J > J _ � O N 0 z m o w Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 08/24/22 AS1004 CCD 003 12/30/22 6 02/15/23 SMOKE CONTROL REVISIONS 03/09/23 AS1007 ELECTRICAL POWER PLAN — LEVEL 2 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER �11 E2.12? c c R r JO L E M U) U) CU J .0 C J 0 n E00 0 Q — E -C3 318 I I �n 6 7 80 9 10 12 SEE SHEETS®AND© FOR ENLARGED UNIT PLANS. El — ❑ 1 ❑FIH� ][I 16 DW� [E] C__ L� JJ 0 REF 00 — SP1-7 OTR ju�6P-22 SP1-38 CCD 003 1 IL- 1 _ P1-3 3 0 Lu IDF DW 00 CCD 003 13006 ❑oo SP1-58 TF EF. AS1007 M 1 I I I I 7701 OoLL e IL- 2+I w L—C323 6P-29 F CCD 003 I I 0 324 0 1 I w I � I YQ 6P-31 ®OW00 --- CCD 003 CCD 003 �P1�i IL-C2 326 CCD 003 6P-29,H,TR Ll ❑ IL-B5 314 Dw L O O REF 00 )0 ❑� O RAF EF. C I I I - - o D DW I I IL-B 5 IL-1132 328 I I I oi ELECTRICAL POWER PLAN - LEVEL 3 SCALE: 1/8" = V-0" 3�_0� CCD 0036P-31 TR Z < EF. < DW I IL-B6 332 I I III■ �. �1■ 31 \ • : .�. i :: ■ =. _ '�,E�i � � _ Ali ■ I TR"SP1-7 00 1 q ir EF. 00, EF. < � I DW -B6 DW IL-B6 336 334 l I I SEE SHEETS F2 20 AND F2 21 FOR ENLARGED UNIT PLANS. ■ 302 � �I � 0 o w � I F -Ij Q 6P-31 � CCD 003 I n Ll 6P-31 Q I STAIR - 02 I I I I I I I CCD 003ST2-03 i CCD 003 6P=29 R — C O EF. 0 v EF. 0 - DW IL 6 DW 8 3 I I NORTH GENERAL POWER NOTES 1. NUMBER ADJACENT TO DEVICE OR HOME RUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEE SHFFT F-i nr-=i n1 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. KEYED NOTES ■ 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 Q0 (N CD 00 d) O Z z O = Q 0 W cn 0 LL z O0 0 z O N > J > J o_0 0 F_ co F_ w z C:) U~ Q� e' N U a REVISIO N DATE REASON FOR ISSUE 1 6/18/21 Addendum #1 4 1/03/22 Addendum #03 12/30/22 CCD 003 03/09/23 AS1007 ELECTRICAL POWER PLAN - LEVEL 3 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 E2.13 Q co 0 GENERAL POWER NOTES N N 1. NUMBER ADJACENT TO DEVICE OR HOME RUN a, INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEE SHFFT F'�)1 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. 1 2 3 4 5 6 7 (8-) 9 10 12 13 SEE SHEETS F2- 0 AND E2.21 KEYED NOTES O FOR ENLARGED UNIT PLANS. 38 NORTHWEST DAVIS, SUITE 300 �] \ PORTLAND, OR 97209 503.245.7100 g 1505 5TH AVE, SUITE 300 418 IL-135 SEATTLE, WA 98101 206.576.1600 IL-Cl 414 I1L-131 IL-136 I1L-131 416 412 410 408 - 1014 HOWARD STREET SAN FRANCISCO CA 94103 415.252.7063 LT 0� I � IF— 0 0 1 I I° Lj � o � � � ©ANKROM MOISAN ARCHITECTS, INC. L L J i J ° T-1-- f7 I I I li Ll - - - - - 1 7Q 6P-27 I � CCD 003 CORRIDOR TR Q I 6P-25 TR SP1-5 TR 4100 CCD 003 D C E N G I N E E R I N G 71=_ p Careful listening. Dynamic solutions. CCD o03 6P-27 TR - - 6P-25 Q 6P-28 0 — — www.drengineering.net °IF -- Z6P-24 Phone:208.288.2181 Project:21AMA01 CCD 003 � CCD 003 �,..,, /� 6P-25 ° 6P-27 /U SP1-38 � � CCD 003Q EF STOR. CCD 003� STOR- +60" -5 CCD 003 E 4005 SP1-5i IL-B1 FE �� Q 6P-26 $� Q 6P-24 420 SP1-38 Q FC-4 ° ELEV. WAITING CCD 003 CCD 003 FS 4000 SP1-38 0 '14A''14B' P-24 N IDF � CCD 003 003 IL-05 (TYPE A) 4006 0 404 0 - - �ASI007 IL-B7 SP1-38 E ASS 07 1-5 P1-58 F IL-C4 411 a002 - �� _ CCD 003 1 413 CCD 003 142'2 Q SP1-50,52 M 1F SP1-58 AS[ 007 FC O AS1007 4 6P-24 LL SP1-38 — —Z-- TmiCCD 003 F 001 LA=�h -- I IL-62 +DEN - 0 - AS[ 007 n 423 SP1-5 SP1-58 L J C, II cn P1-3 I SP1-5 LE� o IL-A1 (TY E I i - 403 ° IL- 1 424 0 IL-13IL-133 (TYPE A) 6P-2 0 401 402 ® CC�03 5 ~ 6P-25 0 CCD 003 IE v l 6P-27 0 6P-27 CO N - - H CO CCD 003 _ CCD 003 -- - d) Z p C) � fi P-25 Q --- ---- — — — — Z z a I CCD 003 LCCD 003 TRO 6P-27 Q O SP1-5NTR — — 6P-25R — CCD 003 SP1-5 TR — — Q T �I a :J - - - - - LU _ � I � � C I p L-C2 42 �� c I� 0 O UN0 Eo o L-B5 IL-B2 JE432 1E Z 4 LLl CD 428 430 �•/ Z - I O > o J > J Z NC) N I Ll Z N Q � Q N U a Id SEE SHEETS F2 2JAND E2.. FOR ENLARGED UNIT PLANS REVISIO N DATE REASON FOR ISSUE 1 6/18/21 Addendum #1 4 1/03/22 Addendum #03 12/30/22 CCD 003 03/09/23 AS1007 1 ELECTRICAL POWER PLAN - LEVEL 4 SCALE: 1/8" = 1'-0" NORTH C6 w 0. E `z ELECTRICAL co > POWER PLAN — U u1 w LEVEL 4 J 0 CONSTRUCTION SETCn 0 E w N DATE PROJECT NUMBER CD CD 03/14/2022 184470 Q U U Q co 0 GENERAL POWER NOTES N N 1. NUMBER ADJACENT TO DEVICE OR HOME RUN o, INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEE®TEM®FOR PANEL SCHEDULES. 1 2 3 4 5 6 7 8 9 10 12 13 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. I I I I I I I I I I I I KEYED NOTES � SEE SHEETS Er-57 AND F2 21 � � � • FOR ENLARGED UNIT PLANS. — — — — — — — — — — — A 38 NORTHWEST DAVIS, SUITE 300 97209 503.245.7100 1505 5TH AVE, SUITE 300 -I SEATTLE, WA 98101 206.576.1600 IL-Cl I1L-B1 IL-B6 I1L-B1 IL-C3 1014 HOWARD STREET 516 512 510 508 506 SAN FRANCISCO, CA 94103 415.252.7063 F L J 51 O ©ANKROM MOISAN ARCHITECTS, INC. _ F- ❑ ❑ ° CEO C�0 CEO r L - o o� Ll F-1 F - --- -- - FLA cc I/N °I - - -1- - - - - - -� DC ENGINEERING 4 CORRIDOR TR 6P-5 510o Careful listening. Dynamic solutions. II I 6P-7 TR SP1-3 TR www.drengineering.net 6P-7 tt - - - - T - - - - Phone:208.288.2181 Project:21AMA01 SP1-3 F 6P-210TR ti L ACT. DIR. OFFIC STOR. ~ 5005 6P 5004 SP1-3 ° SP1-38 FSD _ - - iu - - - - - 6P-21 _ � �- 52U - T91 - �$ 0� P1-3 6P-21 SP1-38 ELEV. WAITING Q FC-5 5000 L'."j SP1-38 ( SD 'I55AA� 5 03 IDF - Q SP1 F IL- 4 IL- 5006 C ASI 007 C5 513 511 SP1-38 EASI00F 504 P1-60 TF _ _ _ L ❑ � 5002 ASI 007 1 SP1-54,56 SP1-60 1 I52A AS1007 5 FIC ASI0007R 170- SP1- 8 CL-62 +DEN -TRASH I 523 SI007 6P-7 SP1 60 D SP1- F 6P-511 1E 5 Q o I I I T 524 O IL-B3 I 502 FV 6P-7 � � ® � 5 I IL-B5 SP1-3 a 5 O -01 I 21 00 - 5 6P-5 - 0 ~ - 51 d) 6P-� z IIIII I O Q T1, TI f I"1 tL Z z CD TR"SP1-3 1 � Q 6P-7(srR 6P R + — — W 0 z O IL-B6 LIJ -Fo 77 IL 2 - - - 5 III III > J o IL-B2 IL-B6 O -0 0 o � p N — o 530 IL-B6 7540 iII- I� z m IL-B5 IL-B6 534 IL-B6 � 528 532 536 Z N Q REVISIO SEE SHEETS E 0 AND EN DATE REASON FOR ISSUE FOR ENLARGED UNIT PLANS. 1 6/18/21 Addendum #1 4 1/03/22 Addendum #03 03/09/23 AS1007 1 ELECTRICAL POWER PLAN - LEVEL 5 SCALE: 1/8" = 1'-0" NORTH cri w E U) ELECTRICAL U) > POWER PLAN - U w w LEVEL 5 J L CONSTRUCTION 0 SET 0 E w N DATE PROJECT NUMBER CD CD 03/14/2022 184470 ry 6 a. U 0 U c c c c c c ( C M U) U) N C CIO ii J .0 C J E n0 T2 3 4 5 6 7 8 9 10 12 13 • 1. I I I I I I I I I I SEE SHEETS®AND© FOR ENLARGED UNIT PLANS , I1I -, - _, -' II,,I1I1II11'1 "II I I.II,I ---,-- -_ -------I---- I,,I II I ,I , :I , '1 I II I -I- II III, "II,I I'I1I 1II----, ------_I----I'I1II, 1 I III III1 1 , 1 ,-ILI1I11' �II 1I- II "I_ --PI, 1-I-r---------I----------, �1"I I , 1 - ,I- - I ,,1I I I 1 _, I 1 1, 11I. 1- , Il 'II ,7,,II 1 , , 1 '_ I------------- �-__-1. , III _ I 1_I,1,1 I, 1,11I,- ) ,I II -Iq ----, _0Q�'' '' o I1,:I I1II�, I1,I1I I� II, , _--- _--L-----T., I, I I 11, 1I, -1I'1I � ,,,I,II I_---,-I��I-1I, I 'I -I,,1],I.,,_-I--�__--- o o 0�II -_--I- oI, L I :1�I',, I " I11I II-1,III 1.,1 1I,II '�'IJ 1 ,IN�III1,11III,I I /Ij-I_ ----, ------- -----'I1I I'I II, I- / I I 17III 'I,11II I ,I1 n ,- I/1 - _ I - I1II I III 1 I 1'I--,-----1-,-I--I_I--II , II_ 11 1I I , I I ' ,I-" , I N I ,1 I ,1-, ' ,I II 11I 1II ,---_---I�--1_--_- -,1I1II I I , °OO , .. ❑ ' RII II ' III ,,I I I II I iI I ,,II, I III ------I--_----I--- /, -�"1I11I IIII , .II I, I 1I1I"I II"�III I, 1I , I1,I� I --� --_- - - ---I_--1,,I11I _," I - ,11"'11I, 1 ',1� I1', � I, I 1�I 1-,-,-1_- ----"-----IIIIIJ,II , ' 1 I 71I I-111� ' ,�LI I-1 I1 , -II1II --,-_--_1 �I I I "I I d,,-III 1 I - - --I--I- .,dI �I--,I I� 1I1'7- I( � IF...I I 11L1, 1UI'1 I� 1I-----_--__�I,I.11 :. ,1. ' 1 1I@1,1_I 1L-I,I1'" -l� I,I-- ------- ,I'I 1"'I I 7I ,,T II,I- , ,-I I-I-----1---,- I,.1I--1 - - I', 1 I- �I "II-, I �I III,I1 '1- 1I,/, ,,' IL ' , -,---_---"--I 1I1I"1, ,I I , 1- , �11 I,I ,,� , III; I'II1--_-----_--__ 11 �,7j ,� II I" I , I,I" ,'I, 11 1,,,1," -_--_--(�---_-�-,-IN1I4 I .I 5I , II, 1111II1_II - I 1 I1�I, 11I I,, "1II1', 1(111 -I �,I,1I , I 11I I ) ----,--_------ 1I a1,, ,1, 1 :` I E,I I 'I�,�,1,II,- --_-__--,-1-,II,, W - ,I,II I , ,III " I --------- I I'_ I ,-�,I,11 - iII1'II� F7III � �I U 1_----I- _,II I , 1, ,,I ,- I_,I --- _----_--I,, "IIIII II _ 1.I,: , , I III,I1'" , 1''-_-- ,� I1���IIi�1�.-jr,_-, I I1_1,11 - I" I, ,1'" -3 , -_-----,--�-I I I1j ,I,,,.I, , ",'I11I 1\I- 11,I II I ,� ,, AAI ,II:� "1I -----I-_----I-- II ' I"--.. II� , "1IIIIIII, I --------,-_I 1rI I�I ,I 1,"II,, I' , _",IL� I11I ID,",,1IEI,----I- _---1-1-1.I , II- -III I 1II - , 1II,,I I:,,I IT_�0 "1,.I1 II,I--_--_1---_---I II, 1_" I 1I ,11-1I '�,,,,,, . , [1, -,,_-_--- ------:I1_I II 9,AI1 ,II11 N 1, I ,,, -1I I 11"II 11 I -', I E1�m11II ,-,P 1�I-I IIE'II " I,, , -I-----_------- �I , ,I , ,1 ,1, I"1, ,'I1 I,IJIIIJI II "�I- I--I-�-,---I----_, , I T"1_III,I II -,I' II _111I I,1.I 'I1I V ',--, II,,I-----_1- --- ----I , " ,AI 1�,I, ,I,,II _ I11I" I" ------_ I---- --- I- 1 I <1" "I1 I1I I �I :1,III I1I=,LL1I,_- ---,I_-II-I1 I 1 I : I ' I ,I-,, , - I,1I 1I I�,-,-- ---.I-�I, I I . , 1- , II, ,I 111�,,- I11-------,'----- LI -IIII II "11I,I.I , I_,I,,L I I 1, 1.I,II1---�--I-_,, I ,, I1 ,1 1,, I,, I ), ,III, 11 I, II .JIII,�-- i.,-I�I _- ," 1I I,'- --_ 10,I-I I 1 /II1� - /,II--, I , 1,1I ,, I "I I'I ---III - ll ', _I--,-- �",,1I, II- I -I__--:I 1, I1 -'I II,,II III"I ------ ---,�," I 1, ,"'1,I� ,-1'L ,7-,'-1_-1I_1 ,, ' I, I �I 7'I11I- ���I� -\\-�) I ,',"I�I I,, II-------, ,,I ,'", ,I I" I1"2, I�, ,'�I,----- 6,'II II 1I-I1 ",,"', ,I1_- -- ,, 'I , ''II"1 I,: -I I,'-� -,I 'I II1 I,, . I, -,I c I I -I--- -I I -II ,I- -,1 r , A 1I ,1I _I--,----_-1" , 1' I,, 1,1I ,I',I1 -----,_1,�II I , --1I1 II-- 1" '1II� I I I I-�---I---1I I1I 11-I1-1 I'1�II,I1- -I I ,, I I IIJI-,I I ---I---- , I -I I 1.1,I,I I ,- '- I 1, -, " I1 ],1 - --II I I , ,, 1II1-- - - '_ -, I,n I"1I1" ---- --,II 1I " 1, II I I11I --I -, l I1 I-=1[_1 II ----I -1I_I ,(I: , I :0-�IIDI-1--1, 1, I I1,!1 1 ]U II- "------I " ,II,I II ,I 1II- I1 ,, I 1I,,IIN-"II ----II , 1 , f,I,1-,-------I I , I1 1- , I I'I<I-1II,--�, 1I�1I -I'_,- F01,I'-- --1 I�II, 111, , I-- " �I, - LII,_,, 1-,I , " � II,' , , 1-:"II" �----- I ., ,- ''----IIj I7' , , 7[]-17, � L II I--I-I-1I ",I ,i, I]_---1II I 1� 'I" -- ,-I -, IE-'I-----I III II_1 I,----I,II,_) I1I F I1dI 1II I --I ,I 1��i�� �_,1r ,1I I-7,-I-----I I III , -II'I 1�I I ---1_-I , ',,, , II� --IIII I, I1I ,I 11-"--_- I,1,,I �I Ir -_ - --,I,- 11I 11 1ILL- ,� jI-I 1I 1� I9, -I---I II I 1, , :� , 1� II ---- I -,"-rI - --�--I_J0, II_1,1_�I,"--- , I '1I I 0:I1I: " ',- --,- 1II ,, I -1----"II1_, _1-1IILI "I I, I 1_-----1,lI,,I_ ' 1 ,- " 'I ---I--,, I , '1 lI I 'I"I ----,-III� I1 ,111,-1 1I' 1E1') I �17--(,'I, 1"Q1I I1'1 ------I) 7 , ,1I1,, I-1,----1 I I 1II I -r,I-�"_-------I 1I,,I�1II 1-�-- I _ ," , ;, ,I II -II--,II -,��1�'1I("- -I,, ,4I��"I1I1I---I-- L= � 1 1 II I - L,I _----II L II, ,I - II�I ----I I. I -11I -I------ � I I III_1j II II I-1-"`, 1I U I 1I II ,1-1I t1 -- I1I I1, E�,I 1 F,1I� �--,II 'I1 1I 'I" - -I 111I1-I--', I 1[I' - _-----1"I 7 ,1,,,1I:--, -_-- ,1, ---II , L I1r1II , II ----I-11 7 ,1I,I 1, II1-0�-�I�-- �,I-I I0`o,�"II, I, -I� --11-I---,1II , ,1I ,�I ,--I-I"r, ,'1;"� II_I,_- -- ; I ;I� ,A-�����i� I--�I 1 I. �1 IIIj6I --1-� " I -I1",-1I,'- I "Iff"I,,- I0-,- �wI,II"0, S-----,:�(�I1I I I"_,,1,, ' I.I, I, ,, T , ------- , ,I3_,I I1--' ,VI I_,--,-17, I'I1" I 1)1I1 I = � I"I- ` I 1,, I'w ,I1 I�IiI -01 ,III� 'I , , II--- -"I r.F_ �- *,,,ll,I, IF1�I 1I-,---_--I- - I , I III ,II,,,1 1, ---1---- I,I'," I , 11''II --1I- -_I _1 I, -, ,II I I �II -_- �1I I I1 I� I , III-- -- I,I I �1I1 11 , I 1,I1I 1'' III I1,I -- ----1,1 ,I�'11'I IIi ---I----I 1 , I'�AI11II ,IiI I ,I1,� -,, 1I:------_---_I� ,1,I1'1 I II, - 111 , I1, , �I I I I1 -1I,I----- -,--"-_--1 I"_,I�I I I I I I I '1I 1-1-I I I, III,� I 1,, I ---'-------- I II11,, 1I' 1II I "1, I , ,,---------I- II I1 , I I 11'7,- 1"'I III I , II"I -----� -----"-"- I,II I I' I ,� 1I , IL --��-I,I I,I LI1, T r,,I, I wI III�I-1--I-1- , 11I':AII _F- _,,,, I I�I'-I---_ ------- II-I I= ,1A1 " �,-,,"- 111III I,_1I , - L I,"-I_I-_-- ---1-o-I'II 7 P,' -1 I I I.-1 %,I II , 1 ,-------1--- l, 1'111 LI,'I"I1I �,I, I ', , III �,I -7_I ,I I .6, I II' ,III, L1,---- I I1,,1 ,,- ,I I II II I,.__1-1------,II,L ,, II, .I 1,II -' I -------- ,"1II 1I �- iI,1-I, ,, "vI ,--l- - -,I- I ,II , IIl ,I�I ,I =j, ,II1II,- �-1 - ,, I -,, �-I 'II,II , I-j 1,-----__---�1II1I, I , ,II, ' ,,', "I1 ',"-I'0---- _,M1J _1_I , -'I 1"I I 1 I -,_II , I - I 1I, ❑ - 0 0 -, ' 1, - 6004 , 11, ,, 11 '.I- I. I '-�11--.I� I;1I, I �I - �- .;I._,1I �Q" II.,I1I II ,7_-IF , I, 1 �1, " II -----: 1I, I I_1I_, ,,.1 1',,I',,,I 1I ,)�I]-1---_-- --��I,1I , ','_ I ,1I '"1 __,I 1I II� , -- I , �rL 11,_ ' , .�, I1I"-�-,I -I----------I,1 �, I I 1I 1 f-,, 7, ,�IIII, I" _--_-_--'- I/,I ' I , ,I",, I, 'II I I ,1 �,I 1 , 71 7�'1- ,11, ,-,I 11 IIE,1 I III -II, , ,I II .II - ' I , -� "-"LI�, 'i11I--I, 1,�� �--_- ---- , III 1I ,I,,'I �, - ',I1,��,I ,,1,I,----_,I---,i----, ,I I,, a1I" ,L, , ,- I-_,�- -----_,riII I,'I'I I I1I,, -', I ' . I,,' ,- , "--_-_�_--------,I ,I ,-1I -1 - '- - . RFI #304 Electrical Outlet Layout - TR ' P 6 9 , 1 I, I'I'I- I"I 1, I �.-I -_ II I,1,, (,I I-',, L7I, 1I--_---I-(--,,I 11I I III1��11I 1I"" � ,1I, IF"IFI_, 1,I ,, I ,-- -�-l-__ ----II-- 1I,I� , _,1 - ,,,I - 1 I1I_'I", I ,I 1, "I"-,-- 1- , II"-----I-I,--- ,,11-I, ,A II ' I 1_, "I I I',1,II ,I I11II " , , _II I,, 1II -"'I ----I--- ----- 1, 1-II.", I _ I L1,1"I'", II- , I - I I_I I 10I 1, ' 'I I I- ------1I- --_II1I I I aI. 11,I,'1I 1 61I,II 1L :I I,I1 I I. fr,,1I , ,�_,,E(,'I- � 1I I--`---_�I111 _II -, -II ,,1 - IL=C3 IL-,1 - , - - .D IL-35 - - - ,"\ 61'8 616 , 614 ❑ 6P- I 6 - ., 1= - - - - - - - -, a .3 - - .- _ ' _ IL- ' - - - FITNESS,'- -' ' ~ , - - - , - - 61 - ; -, � 6007" - ' - . - T EATE MM I Y /CO U 7,,I ��I11II I II,I IIII" I------1--�- �- I, -,-III ,�I.I.I_F'II -" 11,1 I`"1",�II 1 ,I 1- iI1 _� I II'III1I �------_- I --- I ,I" 11 , 11, 1$11 1I11I , 1 �III' ,', I �1I�I�I�I��1,1II-]_,1I,---I---_- II 11I1I 1,, I, , I, 11I�._I- I 1I(, I�II 'IL"I " , =I ,4II I---- ----1---1--�II-�--- �,_I ',IIL11 DW . DW 0 l Oo: ° 2 "" 1 O O REF , O O R_E_F ° _ REF 7. 0 0 -, - ' - -. - - - -, - - - - - - - - 6P--1 TR 6P 6P 11 6P-17 ❑ ��,': - -----I.�---- I .I II II 1,'I I,1I]11, , I 1.I 1I1]I-1I11� 1 I,II ---1, I1II,I lI 1, ""1�I--I-�-----II -------�I III ,I I1 - ', - SP1 , TR` - , - - C I, - - I- - ❑ - ' I1 ------ ----- p 6P-1' RR R' fiO-6 EF. O O I-ILII-=- I 1- I,,, I -'I1IO I "" II 11 II 60"1.0, +4" I ,, _ 4 - , _ Nf 6 6P-26 ' ! 6R-24 6P-20 - - - j +48 ` 14 - 1r - - E II,I, I1 I,I III,I I1 I1' ,1- I, 11,II II ,I, I----- ------ --_---_ I--- 1 1I I I-, I 1I , - " II I11I,'1I,11I 1 1 " I II I IIAI11', II ,,II, ,I. 1 '1I ---�-I------I -_---- ,III1 1I I I1I I � I'1 - I'I 1 II"I --- I-�[I, 1,I , I '1I'I,II ------------I-__-_I -,I� 1"I I I"'I, I ','III,I II �1 I II uI,11'-, 'I 1II 1-L-�-----_---:L------ �111IIII 1 I= , 1- ,, - 11 , ,1I 11" iIII,I" , .1,�-�-----I-,---------,-III I 1--�I71I'I1 ,I, 1 I1 I �I�-I 'I-11' I,I II, � - 1LI, I"--,-�_----_-I- -I I I� �7 II, I I1I"'III11, II- 3 ° ' RFI #255 Elevator Equipment Room Sub Panel & Circuitr 620 Q,09., Y ❑ 6P"20" , , - - - - SP1 13 . D ' 6 -10 , - - w SP 3 6P-20 - - � -. ' y- . - , . - -, - - 3 SALON I'' r - - 'ELEV, WAITING. ' 3 3 J , , . - ' - ' r' I 9-1'Y - 008 - - EL TR 6000 - _ - - - -6M I 6 1 � - - EV.,CON OL . - FS _ , 0 , - - - „ - - - - FSD SP1 38 FSD SP1 '38' IDF FC, - - . - 6005 '6M1' . '16A' , O DW AS1007 6011 6A - IL=C4 ' '6M2" '16B' IL=CS ' YPE A) , -- ' - '-, - - SP1-1 . 6 EF. ❑ SP160 - - ELEC/IDF TF 6P 6P-16 _ 1I, , III �II 1,III,II 11I�I---------_----I -I- -- ,,- I -"I -�11LI,L I1�I ,I1I A ' - I I- 1--'11I-_I-----------I----,1,I , - I II 1II- . 1J1II '�,,I1,II1,,1'�1 -L'-L,I-"II1I, _-'-----I- , I1 1.'1 IF,',I I II1InII 1 �I�IH,'11 I ,I II -Ir, " '---------_I-----_-- -�] ,,,I II - 1; - - .� ' - - ' - - 611- M SP1-38 s 6002 FC " ; I' -, , - -, - - - . 1-1 - - - � . - - - - -A � - I ' - , - -11 - - - P1 60 EL SP1 54,56 M SP60ASI00 ' tL-AZ ' , SI 00 TO MDP1 FSD/F - - 622' - - - 00° , , -1 - - I .. - TF M _ FC 3 -" O;Oo _'. _ - - �. - I - - �S7 6B L' SP, EL 6P"6 1 8 ' - - ASH - - - - - -., . - --- - ---- - 1 - - -, -' w . ��. � - .: , .- 0- - P1-51 EF. EF 1-3_ r," -', �' - .. ' . - -J ' - '1-60 3' - - Q .. ASI-005 - 8P1-1 , -I - -, . 1 ASI007 - -, o - ❑" G ,-c I I1�,-III�1, EIII .. I. ® - IL 1 TYP ,A . 1, - - -82 - ( ) �❑ . 23 603 - - - ^I; - - - - - - RID - - - G 61,00, I IIa .,_- TI 1, I1(, � 1I" �1I--_--_--- ---- -1IP-,II.7I,1"III O I I _ "," II- 1" I OI � II . I ,t1-------I--_-I---,I-I II!I ',1 7",ft ') I"I ,'I�'I, 1I,1 1I,I II, , w,,I---------I-- -I----1', , ,I I,,IIII 1 I O'I.,I,II , -----_-I -------- 1L-Bi - °oo I 624' ,. ,' - w - I -, - - - ;. -1, - - - - �14-B5 w � �_ w w - - -I , - - - - ' 1L-.0 (TYPES ' '_ 6P 1 O O - �DWOO -- - - J 1 6p-1-- _____ -° O-DW 0 0 - '_ - 62 _ 7I - - - - I i I I i I i i I 6P-1 I, _' : ,- ,- lil w ? , . -, - H �, - - - W 0 . - - - - , -".i i - , i J', 1E _ G_ 00° , - OOo - - ' _ _ _ _ __ _ -, ❑ ❑ SP1-1 �' 1 = _ . - - - - - - - )))))))))) - F' - - - - TR - - - -, 6P-1 - - - - -- - - - - - - - - -- - - - _ - P f-1 -. - ;, 6P-T TR SP1 1, TR . , S TR - - - - - - - 00 LJ- 00 _ I -- 00 _ 00 -- 00 K 1. r - r O O R F EF. EF. O O EF. O O EF. O O EF. O O EF. O O 1 , -- - _I�II1I,11IIdII, ,1-111'1 ,_I1----------_------- 1 1I 1I1 I'I II11 1I- , I1, I - F ° i 1_.° a - f L - , 4' �. - ❑ 1, -- - - - - �0 D - - DW ��] - DW E, - DW ] DW -Z] DW 0�] DW ❑❑ ' '' - - -,- -, - - - - - IL-C2 r �' - �. ' 626 - �,_--II--I- F1I1,,1,I I1, , ll. I,I ,,, 1 II1', iL-B5 - - - - - : . - - - - I . _ - -.,I "1 _ ' Q Ei28' I - „ I'. - - - - - - - ' - - - - .. - - - - - IL 136; - -' '-BG IL-I86 ' _; - - 632 ' ' 34 . 63 ' _ ,L - I , !��I _ �.a _ I _ �.� _ICI �I I 11�� oi ELECTRICAL POWER PLAN - LEVEL 6 SCALE: 1/8" = V-0" SEE SHEETS E200 AND E2.21' FOR ENLARGED UNIT PLANS () NORTH GENERAL POWER NOTES 1. NUMBER ADJACENT TO DEVICE OR HOME RUN INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICE SHALL BE CIRCUITED. 2. SEELStiFFT F`� nr-=-1 n1 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. KEYED NOTES O 1 COORDINATE SALON ELECTRICAL REQUIREMENTS WITH SALON EQUIPMENT PROVIDER. 2 FAN IS POWERED AND CONTROLLED BY THE ROOM LIGHTING. 3 FIRE SMOKE DAMPER, ROUTE CIRCUIT THROUGH J-BOX IN ROOM 6002 FOR FIRE ALARM CONNECTION. RFI #255 Elevator Equipment Room Sub Panel &Circuitry RRI'#104 A'menitAlecfrical'Outlet 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. M�: W` DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O rn O o F___ Z z O = 2 Q 0 > W o LL z O0 �LLJ z O (1)> J > J o O -0 0r °' C O N - 0 � z m W 4t Z � U) � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 1 6/18/21 Addendum #1 4 1/03/22 Addendum #03 5 03/14/22 Construction Set 10/24/22 AS1005 03/09/23 AS1007 ELECTRICAL POWER PLAN - LEVEL 6 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 Q LO 00 0 GENERAL POWER NOTES M N 1. NUMBER ADJACENT TO DEVICE OR HOME RUN rn INDICATES POLE POSITION WITHIN PANEL TO WHICH M DEVICE SHALL BE CIRCUITED. 2. SEE RHFFT F-i nr-::3 n1 FOR PANEL SCHEDULES. 3 CONTRACTOR TO VERIFY ALL CONDUCTOR SIZES FOR VOLTAGE DROP. 1 2 3 4 5 6 7 8 9 10 12 13 KEYED NOTES G) 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, R 97209 A 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 g 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. I I I I I I -35,37 �6M-49 6 3/41C-3#10,1 #10G 3/4"C-3#10,1#10G D C ENGINEERING 30/3R/2 M1-27,29 30/3R/3 Careful listening. Dynamic solutions. /4"C-3#10,1#10G RTU 0/3R/2 C www.dcengineering.net HP HP Phone:208.288.2181 Project:21AMA01 4 6C D HP 6B - 33 ZU 6M 1-47 /4"C-3#8,1 #8G EF 3/4' C-2#12,1 #12G 0/3R/2 6 30/3R/2 E 6M1-23,254-� 3/4"C- 0,1#10G I I R I 6A � I I ELS-37394ASI 007 3/4"C-3#10,1#10G 30/3R SP1-79,81QAS1 007 30/3R/2 G 6M1-26,28,3I 0 30/3R/3 3/4"C-3#10,1 #10G -,1#12G 30/3R/3 30/3R/2HP 6M1-19,21 E P F\ 3/4"C-3#10,1 #10G 30/3R/2 I 1 6 -49 6M1-49 wF 6M1-14,16,18 1"C-3#4,1#10G 60/3R/3 OA2 CF 1 6M1-2,4,6 1-1 /2"C-3#2,1 #8G — — — — — — — — — — — — 100/3R/3 G I I I I I I I I CD CV O 00 C7� co Z CD Fi Z Z 6MW49 = ASI 007 ELS-31,33,35 O (n 6M1-49 - , 2G Q 30/3R/3 Q wP ELS-25,27,29 QASI007 — — — — — — — _ — — _ SPF - 1 # 2G e W Cn 30/3R/3 � z SPF O 1 O LIJ O > > o J co J O 01-0 I I I I I F— oo �� Z N a Q LU 04 U a REVISIO 1z N DATE REASON FOR ISSUE L 1 6/18/21 Addendum #1 4 1/03/22 Addendum #03 03/09/23 AS1007 1 ELECTRICAL POWER PLAN - ROOF SCALE: 1/8" = 1'-0" 2 NORTH cl i 00 E `o ELECTRICAL > POWER PLAN — U w J ROOF W J L CONSTRUCTION SET 0 E W 0 N DATE PROJECT NUMBER N 03/14/2022 184470 SHEET NUMBER o- Q E2.17 U L E M U) U) CU J .0 C J 0 E a)n 1 ELEC PLAN - IL-A-1 SCALE: 1/4" = V-0" 5 ELEC PLAN - IL-B-2 SCALE: 1/4" = V-0" 8 ELEC PLAN - IL-B-3 (TYPE A) SCALE: 1/4" = V-0" 2 ELEC PLAN - IL-A-1 (TYPE j h SCALE: 1/4" = 1'-0" UB UB DEN tl n L( I� 1 ;L _�IEmir M."I.1 ®. 3 ELEC PLAN - I L-A-2 SCALE: 1/4" = 1'-0" T BR FAN/HEAT LIGHTING SIGHTING UA 6 ELEC PLAN - IL-13-2 + DEN SCALE: 1/4" = V-0" 9 ELEC PLAN - IL-B-5 SCALE: 1/4" = V-0" KIT#1 Nxx 3:Z EF. 1rfLEC PLAN - I L-B-6 CALE: 1/4" = 1'-0" 4 ELEC PLAN - IL-B-1 SCALE: 1/4" = V-0" 7 ELEC PLAN - IL-B-3 SCALE: 1/4" = V-0" u GENERAL UNIT POWER NOTES 1. DESCRIPTION ADJACENT TO HOME RUN ALGNS WTH THE PANEL DESCRIPTION AND INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICES SHALL BE CIRCUITED. 2 REFER TO F3 nn- E3.04 FOR PANEL SCHEDULES. 3 MOUNTING HEIGHTS FOR ALL ELECTRICAL RECEPTACLES ON THIS SHEE SHALL BE 18" AFF UNLESS OTHERWISE NOTED. 4 ALL 120-VOLT, 15 AND 20 AMP RECEPTACLE OUTLETS IN RESIDENT ROOMS SHALL BE ARC -FAULT PROTECTED TO COMPLY WITH THE NATIONAL ELECTRICAL CODE, AND ALL OTHER STATE AND LOCAL CODES. 5 ALL 15 AND 20 AMP, 125 AND 250 VOLT NON -LOCKING TYPE RECEPTACLE OUTLETS IN RESIDENT ROOMS SHALL BE TAMPER -RESISTANT TYPE TO COMPLY WIHT THE NATIONAL ELECTRICAL CODE, AND ALL OTHER STATE AND LOCAL CODES. 6 REFER TO SHEET E4.02/1 FOR LUMINAIRE SCHEDULE. 7 MOUNTING HEIGHT FOR ELECTRICAL PANELS ON THIS SHEET SHALL BE 48" AFF TO TOP OF PANEL AND MEET ALL 8 PROVIDE ACCESSIBLE HEIGHT SWITCHES FOR THE RANGE HOOD IN TYPE A UNITS WITH RANGES. 0 KEYED NOTES 0 1 IELEC PLAN - I L-C-1 (TYPE A� SCALE: 1/4" = 1'-0" p,N - G ASN/ G tP -II A SS/ONAL LNG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 Cl) o o P- Z z O = Q w C LL z O z >w. 0 z O > J > J O � O N _ 0 z m w o z o U � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 5 03/14/22 Construction Set ELECTRICAL ENLARGED UNITS CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2.20 0 N 00 In 1 ELEC PLAN - IL-C-2 SCALE: 1/4" = V-0" 4 ELEC PLAN - IL-C-5 SCALE: 1/4" = 1'-0" M U) U) CU U w J w UA ,I' I UA UA FAN/HEAT GENERAL. H/J LIGHfiING NN ATH UA UD _ IG TIN E UA oF UA KIT#1 UA - UA N t RE. � Z a 2 ELEC PLAN - I L-C-3 SCALE: 1/4" = 1'-0" 5 ELEC PLAN - I L-C-5 (TYPE Ah SCALE: 1/4" = 1'-0" UB B 6 ELEC PLAN - I L-B-7 SCALE: 1/4" = 1'-0" 3 ELEC PLAN - I L-C-4 SCALE: 1/4" = 1'-0" GENERAL I INIT POWER ni TFS 1. DESCRIPTION ADJACENT TO HOME RUN ALGNS WTH THE PANEL DESCRIPTION AND INDICATES POLE POSITION WITHIN PANEL TO WHICH DEVICES SHALL BE CIRCUITED. 2 REFER TO F3 nn- E3.04 FOR PANEL SCHEDULES. 3 MOUNTING HEIGHTS FOR ALL ELECTRICAL RECEPTACLES ON THIS SHEE SHALL BE 18" AFF UNLESS OTHERWISE NOTED. 4 ALL 120-VOLT, 15 AND 20 AMP RECEPTACLE OUTLETS IN RESIDENT ROOMS SHALL BE ARC -FAULT PROTECTED TO COMPLY WITH THE NATIONAL ELECTRICAL CODE, AND ALL OTHER STATE AND LOCAL CODES. 5 ALL 15 AND 20 AMP, 125 AND 250 VOLT NON -LOCKING TYPE RECEPTACLE OUTLETS IN RESIDENT ROOMS SHALL BE TAMPER -RESISTANT TYPE TO COMPLY WIHT THE NATIONAL ELECTRICAL CODE, AND ALL OTHER STATE AND LOCAL CODES. 6 REFER TO SHEET E4.02/1 FOR LUMINAIRE SCHEDULE. 7 MOUNTING HEIGHT FOR ELECTRICAL PANELS ON THIS SHEET SHALL BE 48" AFF TO TOP OF PANEL AND MEET ALL 8 PROVIDE ACCESSIBLE HEIGHT SWITCHES FOR THE RANGE HOOD IN TYPE A UNITS WITH RANGES. KEYED NOTES 0 7 ELEC PLAN - I L-C-1 SCALE: 1/4" = 1'-0" p,N - G ASN/ � cP -II A ,cF FGI SS/DNAL LNG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 Q0 (N CD 00 d-) O Zz O= >Q L U cn 0 LL z Oz 0 z_ O N > J > J O N _ 0 z m F_ w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 4 1/03/22 Addendum #03 5 03/14/22 Construction Set ELECTRICAL ENLARGED UNITS CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEETNIUMBER E2. N P �`P Acn sy� cP N 9 10 12CD 0 z M -II I I A IFS Fci ERE°G��,�`� IL 0 L S/DNAL EN 04/13/22 J I Kr 24 _----- �`'J --- °----- i 1-1 C-#2,1#80, FC-1 F I I \ L-------- I I Ell K-4376 - - 73 FC ® -761F � � 38 NORTHWEST DAVIS, SUITE 300 K1-35 + 63 o - 77 K1 37 PORTLAND, OR 97209 ® _ 4 I 503.245.7100 K1-59,61 +48 I �_____ 3/4"C-3#10,1#1 92 ,--- - a -33 i i 1505 5TH AVE, SUITE 300 ` SEATTLE, WA 98101 K1-69+ 8' - 96 94 ° --- _-�~` I-" 81 ® K431 I I 206.576.1600 K1-63 + 1014 HOWARD STREET K1-55 + 8' gg --J I SAN FRANCISCO, CA 94103 -- J -27 \/ 415.252.7063 '1K1-7? 7 71 � K ©ANKROM MOISAN ARCHITECTS, INC. 69 86 90 r K1-79 ' o 8 ❑ I I 2 - / 1-29 �K1-39 7 , _ _ _ _ _ DC ENGINEERING K1-41 +36" 8 K2 Careful listening. Dynamic solutions. 7 J J ' _1614,51,53 DRY STOR. ROOM K1-46,48 www.drengineering.net L-_ 1-1/2'C-4#3,1 1012 5 Phone:208.288.2181 Project:21AMA01 5 1 P-24 K1-65 67 3 z K1-1 K1 - ... K-44 _= OFF. t . \YLaK1 - - I K�:K-44 K-440 L+I L IN L ___ I 1 ELECTRICAL POWER PLAN - ENLARGED KITCHEN PLAN SCALE: 1/4" = V-0" KITCHEN & BISTRO UTILITY SCHEDULE - 1 ELEC HW HW CW WASTE GAS EXH EXH SUP SUP ITEM QTY DESCRIPTION MANUFACTURER MODEL FURNISHED BY INSTALLED BY VOLTS PHASE AMPS HP TYPE AFF ELECTRICAL COMMENTS SIZE AFF FLOW SIZE AFF TYPE DIA AFF MBTU DIA AFF PLUMBING COMMENTS WIDTH DEPTH CFM S.P. WIDTH DEPTH CFM S.P. VENTILATION COMMENTS ITEM 1 1 WALK-IN FREEZER / COOLER AMERICAN PANEL AMERICAN PANEL KEC KEC 120 1 8.0 DIR STUB DOWN, SEE DETAIL "5" SHEET FS-9 FOR WIRING 1 ASSEMBLY DIAGRAM 2 1 EVAPORATOR COIL(COOLER) AMERICAN PANEL ADT-120AEK KEC KEC 120 1 2.0 DIR STUB DOWN, SEE DETAIL "5" SHEETM FOR WIRING FS 1" 2 DIAGRAM 3 1 COMPRESSOR REMOTE, AIR-COOLED AMERICAN PANEL D8AJ-0200 KEC KEC 208 3 8.8 DIR VERIFY LOCATION OF ROUGH -IN 3 N 4 1 WALK-IN FREEZER / COOLER AMERICAN PANEL AMERICAN PANEL KEC KEC 120 1 8.0 DIR STUB DOWN, SEE DETAIL "5" SHEETM FOR WIRING 4 O ASSEMBLY DIAGRAM 00 - 5 1 EVAPORATOR COIL(FREEZER) AMERICAN PANEL ADT-120AEK KEC KEC 208 1 1.4 DIR STUB DOWN, SEE DETAIL "5" SHEET FOR WIRING FS 1" 5 DIAGRAM O 6 1 COMPRESSOR REMOTE, AIR-COOLED AMERICAN PANEL DJAC-0200 KEC KEC 208 3 13.7 DIR VERIFY LOCATION OF ROUGH -IN 6 0 0 29 1 DOOR TYPE DISHMACHINE - TALL JACKSON TEMPSTAR HH-E LEASE LEASE 208 1 81.4 2 72" 3/4" 72" 1.2 1/2" 18" COLD WATER TEMPERING KIT 29 Ur 40 1 FOOD PROCESSOR ROBO COUPE R401 KEC KEC 120 1 12.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, 40 Z Z VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) O 42 1 FOOD SLICER UNIVEX 6612S NSF8 KEC KEC 120 1 4.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, 42 VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) Q 43 1 LOW VOLTAGE COOK & HOLD OVEN FWE LCH-6-LV-G2 KEC KEC 120 1 17.2 43 Q 44 1 CABINET, HOLDING METRO C519-CFC-4 KEC KEC 120 1 16.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, 44 VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) W C6 8 T Y I I S 1 06 C 4" 58 Q 60 1 UNDERCOUNTER REFRIGERATOR TRUE TUC-27-HC-LP KEC KEC 120 1 2.0 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 CONDENSATE EVAPORATOR VENTILATION REQUIRED TO EXHAUST 2.2 MBTU'S 60 U. Z PER HOUR (BY MECHANICAL DIVISION) Q O 0 1 A B B - 4 4 64 1 UNDERCOUNTER FREEZER TRUE TUC-27F-HC-LP KEC KEC 120 1 5.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, CONDENSATE EVAPORATOR VENTILATION REQUIRED TO EXHAUST 2.1 MBTU'S 64 VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) PER HOUR (BY MECHANICAL DIVISION) > 0 68 1 CONVECTION STEAMER CLEVELAND 21CGA5 KEC KEC 120 1 4.0 REC 18" 3/4" 36" FS 1 1/4" 70 1/2" 18" (2 @ 3/4" C.W) RUN (1) C.W. FROM ITEM 35, WATER 68 O i coFILTER. PROVIDE QUICK DISCONNECT J > J 69 1 REFRIGERATED CHEF BASE RANDELL 20048SC KEC KEC 120 1 6.0 REC 18" CONDENSATE EVAPORATOR 69 rn TO N 73 1 DUMP STATION HATCO GRFHS-16 KEC KEC 120 1 9.1 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 73 + I� Z m 1 O C C 1 1 0 A A. 1 A. ) 3" A. 0 / I S A O LLJ it 76 1 TYPE 1 EXHAUST HOOD CADDY EXHAUST HOOD KEC KEC 1 DIR (2 @ 120V AT 15.0 AMPS EA.) STUB DOWN; LIGHT AND FAN 34" 10" 4200 1.40 (2 @ 12" XaALaPPPLY AT 1,680 CFM EA., 0.20 76 z O (n SWIG{ BY ELEC. DIV; AUTOSTART/ STOP FAN INTERLOCK. S.P.) SEEIERV 1ISHEETS FOR ADDITIONAL _ SEE -1 SHEET FOR ADDITIONAL INFORMATION AND INFORMATION AND DETAILS N U La DETAILS 77 1 FIRE SUPPRESSION SYSTEM ANSUL R-102 KEC KEC 120 1 2.0 DIR STUB DOWN, CONDUIT RUN ABOVE CEILING 77 78 1 HEATED PLATE DISPENSER LAKESIDE 6212 KEC KEC 120 1 7.5 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 78 80 1 CHEF'S COUNTER CUSTOM CHEF'S TABLE KEC KEC 208 3 100.0 DIR STUB UP, CONNECT TO FIXTURE MOUNTED JBOX (BY 80 ELECTRICAL DIVISION) REVISIO 81 2 DROP -IN SOUP WELL APW Wyott SM-50-11D UL KEC KEC 208 1 2.4 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 FS-GREASE 1/2" 81 N DATE REASON FOR ISSUE 83 1 MICROWAVE OVEN ACP, INC MDC12A2 KEC KEC 120 1 16.8 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 83 4 1/03/22 Addendum #03 84 1 CONVEYOR TOASTER HATCO TQ-800HBA KEC KEC 208 11 15.8 IREC I PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 84 5 03/14/22 Construction Set 85 2 OVERHEAD FOOD WARMER HATCO GRAHL-66 KEC KEC 120/208 1 10.0 JBOX PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 85 86 1 HOT FOOD TABLE RANDELL 3614 KEC KEC 208 1 16.6 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 FS-GREASE (4 @ 1/2' WASTE) MANIFOLD DRAIN LINES 86 87 1 REFRIGERATOR, SANDWICH/SALAD RANDELL 9305-7 KEC KEC 120 1 5.5 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 CONDENSATE EVAPORATOR 87 PREP 89 1 SODA & ICE BEVERAGE DISPENSER LANCER 85-20406-0-0-31E BY VENDOR BY VENDOR 120 1 3.0 48" 1/2" 48" RUN C.W FROM ITEM 93, WATER FILTER. VERIFY 89 REQUIREMENTS WITH VENDOR SUPPLIED EQUIPMENT 90 1 BAG -IN -BOX SYSTEM EAGLE 3B2136C BY VENDOR BY VENDOR 120 1 15.0 REC 72" VERIFY REQUIREMENTS WITH VENDOR SUPPLIED 1/2" 72" VERIFY REQUIREMENTS WITH VENDOR SUPPLIED 90 EQUIPMENT EQUIPMENT 92 1 HIGH VOLUME COFFEE DISPENSER NEXT-GEN NG-300 BY VENDOR BY VENDOR 208 1 30.0 48" NEMA L-14-30 1/2" 110 - 140 DEGREE WATER CONNECTION 92 94 1 REFRIGERATOR TRAULSEN G11010 KEC KEC 120 1 7.4 REC 84" CONDENSATE EVAPORATOR VENTILATION REQUIRES TO EXHAUST 2.2 MBTU'S 94 PER HOUR (BY MECHANICAL DIVISION) 95 1 ICE CUBER MANITOWOC IDT-0502A KEC KEC 208 1 11.5 JBOX 72" 1/2" FS 1/2" RUN C.W FROM ITEM 35, WATER FILTER VENTILATION REQUIRED TO EXHAUST 5.0 MBTU'S 95 PER HOUR (BY MECHANICAL DIVISION) 96 1 JUICE DISPENSER CORNELIUS 721404101JUl BY VENDOR BY VENDOR 120 1 9.0 48" 1/2" 48" RUN C.W FROM ITEM 93, WATER FILTER. VERIFY 96 I T T V R U IP E �:L" '' , 97 1 ICE CREAM CABINET MASTER-BILT DC-4D 120 1 2.7 REC 18" CONDENSATE EVAPORATOR 97 w 5 E KITCHEN & BISTRO UTILITY SCHEDULE - 2 U) ELECTRICAL FURNISHED ELEC HW HW CW WASTE GAS EXH EXH SUP SUP CIO ITEM QTY DESCRIPTION MANUFACTURER MODEL BY INSTALLED BY VOLTS PHASE AMPS KW HP TYPE AFF ELECTRICAL COMMENTS SIZE AFF FLOW SIZE AFF TYPE DIA AFF MBTU DIA AFF PLUMBING COMMENTS WIDTH DEPTH CFM S.P. WIDTH DEPTH CFM S.P. VENTILATION COMMENTS ITEM ENLARGED U B1 1 HIGH VOLUME COFFEE DISPENSER NEXT-GEN NG-300 BY VENDOR BY VENDOR 208 1 30.0 REC 48" VERIFY REQUIREMENTS WITH VENDOR SUPPLIED 1/2" RUN C.W. FROM ITEM B22, WATER B1 EQUIPMENT FILTER w KITCHEN PLANS & B6 1 REFRIGERATED SANDWICH PREP TABLE TRUE TSSU-27-08-ADA-HC KEC KEC 120 1 3.5 REC 18" CONDENSATE EVAPORATOR B6 c B7 1 REFRIGERATED DISPLAY CASE STRUCTURAL CONCEPTS C03324R KEC KEC 120 1 12.0 REC 18" CONDENSATE EVAPORATOR B7 B9 1 HEAVY-DUTY BAGEL TOASTER WARING COMMERCIAL WCT805B KEC KEC 208 1 2.7 REC 48" B9 CONSTRUCTION o B10 1 CASH REGISTER OWNER OWNER BY OWNER BY OWNER B10 a) Bill1 NON REFRIGERATED DISPLAY CASE (COUNTERTOP) STRUCTURAL CONCEPTS CGS2830 KEC KEC 120 1 0.4 REC 48" B11 SET U) B14 3 INDUCTION EQUIPEX GL650UC KEC KEC 1 REC (3 @ 120V AT 6.0 AMPS EA.)STUB UP, CONNECT TO B14 o FIXTURE MOUNTED OUTLET, INTER -CONNECT THRU E CONTROLS (BY ELECTRICAL DIVISION) w B15 1 ICE MAKER HOSHIZAKI AMERICA, INC. C-80BAJ-ADDS KEC KEC 120 1 4.0 REC 18' 1/2" FS 1/2" RUN C.W. FROM ITEM B22, WATER VENTILATION REQUIRED TO EXHAUST 1.8 B15 N FILTER MBTU'S PER HOUR (BY MECHANICAL DIVISION) DATE PROJECT NUMBER N B20 1 SINGLE DOOR WINE COOLER PERLICK HB24WS KEC KEC 120 1 1.6 REC STUB UP, CONNECT TO FIXTURE MOUNTED OUTLET CONDENSATE EVAPORATOR B20 N (BY ELECTRICAL DIVISION) 03/14/2022 184470 B21 1 SINGLE DOOR BEER COOLER PERLICK HB24BS KEC KEC 120 1 1.6 REC STUB UP, CONNECT TO FIXTURE MOUNTED OUTLET CONDENSATE EVAPORATOR B21 SHEET NUMBER � I (BY ELECTRICAL DIVISION) 6 B23 1 7" PANINI,IRN,GRV,ELEC, 208V STAR MANUFACTURING 9D-PGT71E-230V KEC KEC 120 1 111.9 REC 48" B23 a a B24 1 UNDERCOUNTER REFRIGERATOR TRUE TUC-48-LP-HC KEC KEC 120 1 13.0 1 REC 18" CONDENSATE EVAPORATOR B24 5 Q U 0 U c 7 1 2 3 4 5 6 7 8 9 10 12 13 II 4 SPECIAL SYSTEMS POWER PLAN - LEVEL P1 I SCALE: 1/8" = V-0" Lp NORTH GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 4-4" CONDUITS TO PROPERTY LINE FOR INCOMMING COMMUNICATIONS SERVICES. COORDINATE WITH PROVIDERS FOR LOCATIONS. 3 3-4" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4W. 4 SEE SHEET TSnn FOR CONDUIT REQUIREMENTS. 0 . G =Nz- WA Sly k /STE SS/DNAL ENG 05/19/23 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) O o P- Zz O= Q C) L U cn 0 LL z O z 0 z_ O N > J > J O N _ 0 z m F- w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 CCD 007 05/19/23 SPECIAL SYSTEMS POWER PLAN — P1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 c c R 1 2 3 4 5 6 7 8 9 10 12 I I I I I I I I I I I PARKING GA�AGE RAMP 1040 FF- �— —� — — — 3 —�— C-1 o u u m 13 -61 13 — — — — ---8 IT IL - I I I I I I I I I I EO I 1 SPECIAL SYSTEMS POWER PLAN - LEVEL 1 SCALE: 1/8" = 1'-0" I I I 'I II `LLLLI I I I TRASH COLLECTION �I ---------------------------------------------I NORTH GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 3-4" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4W. 3 SEE SHEETEF FOR CONDUIT REQUIREMENTS. of 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) 0 o P- Z z O = Q C) W o LL z O 0 >w. 0 z O > J > J _� O -0 O _ 0 I� z m F— W p Z oN U ~ � Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 SPECIAL SYSTEMS POWER PLAN - LEVEL 1 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E2 c c 1 2 T T 5 6 7 4 SPECIAL SYSTEMS POWER PLAN - LEVEL 2 SCALE: 1/8" = V-0" 8 i c�rr C�LJrrTC� rn �n AAlf rn n4 JLL JI ILL 1 J LL.L I FOR ENLARGED UNIT PLANS 9 10 12 13 NORTH GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 34" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4W. of 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD 00 d-) O Zz O= >Q W cn 0 LL z Oz 0 z_ O N > J > J O N _ 0 z m F_ w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 SPECIAL SYSTEMS POWER PLAN — LEVEL 2 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 c c :o b L C� E co M J 1J J 11 C J 0 F 1 2 3 4 5 0,0 O'C IL-C 318 _LL a ILU Oo0 DW O0 EF. ❑ IL-A2 2 LJ I �-u III �iDW0O u STAIR - 01 ST1-03 6 � L ❑ IL-Cl I 316 \ ❑ IL-65 314 DW DW L L O O REF 0 0 R-E-F F00�L 00 O O RAF. I � I o D 77- IL-C2 IL-135 326 328 4 SPECIAL SYSTEMS POWER PLAN - LEVEL 3 SCALE: 1/8" = V-0" 7 8 9 SEE SHEETS F2 2n AND F2 21 FOR ENLARGED UNIT PLANS. IL-131 IL-136 - IL-131 312 L310 308 jL o LDW o 00° F - - 0.0° �- 00 00 , REF REF REF. L DW I I I IL-B6 1 332 L DW IL-B6 334 SEE SHEETS F220 AND© FOR ENLARGED UNIT PLANS. CORRIDOR 3100 STO . 10 12 13 g I — L� IF- rt n •n " ■IIFE IL-B3 302 E::�[] �u I i IF EF. O O EF. O O EF. C L -1 DW DW DW I I I I IL-66 IL-136 IL-136 336 1 338 340 NORTH GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 34" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4W. of 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O d) O o P- Zz O = >Q W cn 0 LL z O 0 z O N > J n3 J O -0 O N _ 0 I� Z m W Z o U Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 SPECIAL SYSTEMS POWER PLAN — LEVEL 3 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 c c 422 "� IL-C2 426 1 SPECIAL SYSTEMS POWER PLAN - LEVEL 4 SCALE: 1/8" = 1'-0" _ L=--��T=I= IL-B5 414 0 7 8 SEE SHEETS E2.20 AND 17221 FOR ENLARGED UNIT PLANS. DF IL-B1 412 ❑ I 14 02 I I I I I4 B6 IL-B6 410 -1 I - - - - CORRIDOR 4100 u L 31C IL-B6 434 SEE SHEETS AND© FOR ENLARGED UNIT PLANS 9 10 12 I I I I IL-B6 436 I I I � IL-B1 408 I I IL-B6 438 I I IL-05 (TYPE A) I 404 1 I IL-1133 (TYPE A) 402 U IL-B6 440 Li NORTH 13 GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 3-4" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4nr I. of 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD d-) O Zz O= Q C) L U v6 0 LL z O0 >w.0 z o >� J > J O � O N _ 0 z m Lu o Z oN U) ~ Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 SPECIAL SYSTEMS POWER PLAN - LEVEL 4 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 c c 1 2 3 4 5 6 7 8 9 10 12 13 i 4 SPECIAL SYSTEMS POWER PLAN - LEVEL 5 SCALE: 1/8" = 1'-0" or= our=ro E71) nn nnin Mn 114 SEE SHEETS 1702 0 AND© FOR ENLARGED UNIT PLANS. NORTH GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 3-4" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4W. of 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD 00 d-) O Zz O= >Q W cn 0 LL z 0 0 z_ O N > J > J O N _ 0 z m F- w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 SPECIAL SYSTEMS POWER PLAN — LEVEL 5 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 c c 1 2 3 4 5 1 SPECIAL SYSTEMS POWER PLAN - LEVEL SCALE: 1/8" = 1'-0" 6 7 CCC CLJ CCTC C7 7/1 AAlr% C 8 9 10 12 13 -- ILL I V � API -96A_ f mU FOR ENLARGED UNIT PLANS NORTH GENERAL SPECIAL SYSTEMS NOTES 1. ROUTE ALL COMMUNICATIONS CABLING ABOVE ACCESSIBLE CEILIG IN CORRIDORS. KEYED NOTES 1 RECEPTACLE TO BE MOUNTED ABOVE CEILING. COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 2 4-SQUARE DEEP BOX/2-GANG MUDRING WITH 3/4" CONDUIT TO ACCESSIBLE CEILING FOR AV PANEL. 3 4-SQUARE DEEP BOX/2-GANG MUDRING WITH 3/4" CONDUIT TO ACCESSIBLE CEILING FOR CONTROL PANEL. 4 MOUNT RECEPTACLES TO CABLE TRAY DIRECTLY ABOVE EQUIPMENT, COORDINATE WITH LOW VOLTAGE CONTRACTOR FOR MOUNTING LOCATION. 5 3-4" SLEEVES BETWEEN COMMUNICATIONS ROOMS. PROVIDE FIRE STOPPING AS REQUIRED. REFER TO SHEET T4W. of 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 (N CD 00 d-) O Zz O= >Q W cn 0 LL z Oz 0 z_ O N > J > J O N _ 0 z m F- w o Z oN U ~ � Q Q LU N U a REVISIO N DATE REASON FOR ISSUE 03/09/23 AS1007 SPECIAL SYSTEMS POWER PLAN — LEVEL 6 CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER III E2.36 c c c c c c r� ASI 004 FI #85: EF-P3 Submittal Follow -Up PANELBOARD SCHEDULE PANEL: PP VOLTAGE: 208/120V PHASE:3 WIRE:4 AMPERE RATING: 600A SC RATING: 22K A.I.C. MAIN: MAIN LUG ENTRY: I MOUNTING: SURFACE LOADS: AMPS VA PHASE A: 514 61719 PHASE B: 491 58959 PHASE C: 435 52226.1 TOTAL: 120730.2 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) 2880 VEHICLE CHARGING STATION 3 40 2 1 A 2 20 1 2 REC- MAINTENANCE 720 2880 * 3 ' 3 B 4 20 1 2 REC- MECHANICAL 480 2880 VEHICLE CHARGING STATION 3 40 2 5 C 6 20 1 2 REC-STORAGE 360 2880 *** 3 * * 7 A 8 20 1 2 REC - PARKING LEVEL CORE 1080 2880 VEHICLE CHARGING STATION 3 40 2 9 B 10 20 1 3 EWH-2 VEST. 006 EF-2 BLR 0005, EF-3 DBF-1 LAUN D , • 2880 * 3 11 C 12 20 1 4 2880 VEHICLE CHARGING STATION 3 40 2 1800 13 A 14 20 1 3 WASHING MACHINE 2880 * 3 15 B 1 2880 VEHICLE CHARGING STATION 3 40 2 17 - 2880 *'* ' ' A 20 15 3 3 (2) EF-P3 1176 2880 VEHICLE CHARGING STATION 40 2 1 B 22 3 1176 2880 * 3 C 24 3 * 1176 2880 VEHICLE CHARGING STATION 3 40 2 25 30 2 D YE 1 0 2880 ' 3 27 B 28 ' 3 1500 2880 VEHICLE CHARGING STATION 3 40 2 29 C 30 * 3 1500 2880 ' 3 31 A 32 1 20 3 1 3 IDRYER 1500 2880 VEHICLE CHARGING STATION 3 40 2 33 B 34 ' 3 ' 1500 2880 * 3 35 C 36 3 1500 2880 VEHICLE CHARGING STATION 3 40 2 37 A 38 20 2 3 DSO/DSI-1 1320 2880 ' 3 39 B 40 3 ' 1320 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 41 C 42 30 3 3 EF-P1 2640 2880 *** 3 43 A 44 * 3 *** 2640 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 45 B 46 ' 3 "' 2640 2880 ' 3 47 C 48 20 2 4 DSO/DSI-2 1920 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 49 A 50 * 4 * 1920 2880 3 51 B 52 20 2 4 DSO/DSI-3 1320 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 53 C 54 ' 4 ' 1320 2880 *** 3 * * 55 A 56 20 2 4 DSO/DSI-4 1920 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 57 B 2880 "' 3 ' ' 59 C 60 20 1 SPARE 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 61 A 62 2880 *** 3 63 B 20 9F-1 t20 2880 FUTURE VEHICLE CHARGING STATION 3 C 20 1 3 EWH-2 STAIR 1038 1500 2880 ' 3 A 8 15 3 3 EF-P3 588 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 69 B 3 588 2880 * 3 * 71 C 72 3 8 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 73 A 74 60 2 3 HEAT TRACE 3255 2880 "' 3 * * 75 B 76 * 3 "' 3255 2880 FUTURE VEHICLE CHARGING STATION 3 40 2 77 C 1 78 20 1 2 1 3 HEATTRACE 480 2880 *** 3 * I * 79 A 80 * * 3 *'* 480 1200 MOTORIZED DOOR 1017,1040 4 20 1 1 81 B 82 20 1 SPARE 1200 MOTORIZED DOOR 1030,1031 1 4 20 1 1 83 C 84 20 1 ISPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING OVA 210-19 125% 0 VA G - DENOTES GFCI RATED BREAKER RECEPTACLES 2640 VA 220-44 10kVA @ 100%, ELSE @ 50% 2640 VA H - PROVIDE HACR TYPE BREAKER MISC. 157442 VA 220-60 100% 157442 VA MOTOR LARGEST MOT.: 3840 12822 VA 220-50 100%+ LARGEST x 25% 13782 VA KITCHEN # OF KIT. UNITS: OVA 220-56 0 VA TOTAL 480 A 483 A PANELBOARD SCHEDULE PANEL: 3P VOLTAGE: 208/120V PHASE:3 WIRE:4 AMPERE RATING: 100A SC RATING: 42K A.I.C. MAIN: MAIN LUG ENTRY: MOUNTING: SURFACE LOADS: PHASE A: PHASE B: PHASE C: TOTAL: AMPS VA 67 8082 91 10870 74 8900 27852 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES I CKT I NO PHASE CKT NO AMPS/ POLES LOAD I TYPE NOTE LOAD SERVED LOAD (VA) SPARE 1 22111 1 A 2 20 1 SPARE SPARE 20 1 3 B 4 20 1 SPARE ISPARE ASI 007 SPARE 1 1 20 1 1 1 5 1 C 1 6 1 20 1 1 1 1 CCD 003 1260 1080 1080 Q ASI AJI 007 900 Q 540 720 REC-CORRIDOR 2000 REC - CORRIDOR 2000 REC - STOR 2005, STOR 2004, JAN 27 O 0 SPARE REC-COURTYARD REC - COURTYARD FLOOR REC - COURTYARD CANOPY KITCHEN ASI 001 Q CCD 003 180 300 REC - CANOPY BAR TAP REC - CANOPY STRING LIGHTS SPARE ASI ASI ASI 7000 VA 220-60 100% 7000 VA HP-1B PANELBOARD SCHEDULE PANEL: IL VOLTAGE: 208/120V PHASE:3 WIRE:4 AMPERE RATING: 100A SC RATING: 42K A.I.C. ENTRY: MOUNTING: SURFACE LOADS: Amps VA LOAD TYPES: 1 = LIGHTING REMARKS: PHASE A: 29 3456 2 = RECEPTACLES PHASE B: 22 2648 3 = MISC PHASE C: 20 2459 4 = MOTOR TOTAL: 8563 5 = KITCHEN LOAD LOAD AMPS/ CKT CKT AMPS/ LOAD (VA) LOAD SERVED NOTE TYPE POLES NO PHASE NO POLES TYPE NOTE 324 LTS - LVL P1 PARKING 1 20 1 1 A 2 20 1 1 LTS -LVL F 405 LTS -LVL 1 PARKING 1 20 1 3 B 4 20 1 1 LT LVL P1 200 LTS - BLDG EXTERIOR 1 20 1 5 C 6 20 1 1 LTS - LVL 2 15 L - U A D LL C C 20 1 A 8 20 1 1 LT-7- LVL SPARE 20 1 9 10 20 1 1 LTS-LVL2 A 2 1 12 20 1 1 LTS -LVL1 c 1-0 SPARE 20 1 13 A 14 20 1 1 LTS - LVL 1 Is SPARE 30 2 15 B 16 20 1 1 LTS -LVL 1 I SPARE - - 17 C 18 20 1 SPARE 310 7 SPARE 30 2 19 A 20 20 1 SPARE SPARE - - 21 B 22 20 1 SPARE SPARE 20 1 23 C 24 20 1 SPARE SPARE 20 1 25 A 26 20 1 SPARE SPARE 20 1 27 B 28 20 1 SPARE SPARE 20 1 29 C 30 20 1 SPARE SPARE 20 1 31 A 32 20 1 SPARE SPARE 20 1 33 B 34 20 1 SPARE SPARE 20 1 35 C 36 20 1 SPARE SPARE 20 1 37 A 38 20 3 SPARE SPARE 20 1 39 B 40 - - SPARE SPARE 20 1 41 C 42 - - SPARE LOAD SERVED )R, BOILER, LA VEC�S F 1017 LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 8563 VA 210-19 125% 10704 VA G - DENOTES GFCI RATED BREAKER RECEPTACLES OVA 220-44 10kVA @ 100%, ELSE @ 50% 0 VA H - PROVIDE HACR TYPE BREAKER MISC. OVA 220-60 100% 0 VA MOTOR LARGEST MOT.: 0 OVA 220-50 100%+ LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS: 0 0 VA 220-56 0 VA TOTAL 24 A 30 A PANELBOARD SCHEDULE 07 ANEL: 6L 1OLTAGE: 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 100A SC RATING: 42K A.I.C. MAIN: MAIN LUG NTRY: MOUNTING: SURFACE 1 DADS: MPS VA PHASE A: 23 2759 PHASE B: 13 1543 004 PHASE C: 11 1280 TOTAL: 5582 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: LOAD VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) RFI SPARE 20 1 1 A 2 20 1 1 -LVL 4 VEST., CORRIDOR 1182 SPARE 20 1 3 B 4 20 1 1 - 1182 SPARE 20 1 5 C 6 20 1 1 LTS - LVL 6 VEST., 1020 SPARE 20 1 7 A 8 20 1 1 - 1067 SPARE 20 1 9 B 10 20 1 1 - ,IDF 322 SPARE 20 1 11 C 12 20 1 1 LIS-LVLb HINESS, SALON 260 SPARE 20 1 13 A 14 20 1 1 LTS - LVL 6 THEATER 510 SPARE 30 2 15 B 16 20 1 1 LTS - LVL 6 EXTERIOR 39 SPARE - - 17 C 18 20 1 SPARE SPARE 30 2 19 A 20 20 1 SPARE SPARE - - 21 B 22 20 1 SPARE SPARE 20 1 23 C 24 20 1 SPARE SPARE 20 1 25 A 26 20 1 SPARE SPARE 20 1 27 B 28 20 1 SPARE SPARE 20 1 29 C 30 20 1 SPARE SPARE 20 1 31 A 32 20 1 SPARE SPARE 20 1 33 B 34 20 1 SPARE SPARE 20 1 35 C 36 20 1 SPARE SPARE 20 1 37 A 38 20 3 SPARE SPARE 20 1 39 B 40 - SPARE SPARE I 1 1 20 1 1 1 41 C 42 - - SPARE ASI C )ING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: TING 5582 VA 210-19 125% 6978 VA G - DENOTES GFCI RATED BREAKER PTACLES 0 VA 220-44 10kVA @ 100%, ELSE @ 50% 0 VA H - PROVIDE HACR TYPE BREAKER 0 VA 220-60 100% 0 VA lR I AR('FST Mr)T - n n VA 22n-Sn 100 % + I ARrFST x 9..1 % n VA 003 PHASE C: 103 12400 RECEPTACLES 3420 VA 220-44 10kVA @ 100%, ELSE @ 50% 3420 VA N - DENOTES NEW BREAKER REQUIRED. MISC. 13614 VA 220-60 100% 13614 VA R - DENOTES TO REUSE EXISTING BREAKER. MOTOR LARGEST MOT.: 17640 17640 VA 220-50 100%+ LARGEST x 25% 22050 VA H - PROVIDE HACR RATED BREAKER KITCHEN # OF KIT. UNITS: 0 VA 220-56 0 VA TOTAL 113 A 130 A PANELBOARD SCHEDULE I PANEL: 1P VOLTAGE: 208/120V PHASE: 3 WIRE:4 AMPERE RATING: 200A SC RATING: 42K A.I.C. MAIN: MAIN LUG ENTRY: MOUNTING: SURFACE LOADS: Amps VA PHASE A: 167 20030 PHASE B: 208 24974 PHASE C: 149 17868 TOTAL: 62872 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED 1080 RE - RI ERR M,PARKIN 2 20 1 1 A 2 20 1 2 SPARE 180 REC- MECHANICAL 2 20 1 3 B 4 20 1 2 SPARE 180 REC - GENERATOR 2 20 1 5 C 6 20 1 2 SPARE SPARE 30 3 7 A 8 20 1 2 SPARE 9 B 1 *** * 11 C 12 20 1 ISPARE 900 REC - SALES MANAGER 2 20 1 13 A 14 20 1 SPARE 540 REC - EXEC DIR 2 20 1 15 B - SPARE 20 1 17 C 18 20 1 3 WATER COOLER ASI 0 720 REC- RECEPTION, BUSINESS OFFICE 2 20 1 19 A 20 20 1 2 REC- RR 1005.1006,1019A,1026 900 REC - DISCOVERY/CONF 2 20 1 21 B 22 20 1 2 REC - RE UEIV, 76RR, TRA H, E 720 RE - MAIL, ELEV LOBBY, CORRIDOR 2 20 1 23 C 24 20 1 2 1 REC - DRY STOR 1080 REC - DINING 2 20 1 25 A 26 20 1 2 REC - FAMILY ROOM REFRIGEF - I B 28 20 1 2 REC - FAMILY ROOM MICROWA SPARE 20 1 29 C 30 20 1 2 REC - FAMILY ROOM SPARE 20 1 31 A 32 20 1 3 EWH-1 RISER ROOM 1034 20 1 33 B 34 20 1 SPARE ter ubs ituti0n U -1 20 1 35 C 36 15 2 4 FC-1E 20 1 37 A 38 * 4 P E 20 1 39 B 40 15 FC-1F ASI 004 C 42 4 * \S1 007 1200 REC- EMP. LOUNGE REFRIGERATOR 5 20 1 43 A 44 20 1 SPARE 1000 REC- EMP LOUNGE MICROWAVE 5 20 1 45 B 46 30 2 4 HP-1E 360 REC - EMP LOUNGE COUNTER 2 20 1 47 C 48 - - 4 - SPARE 20 1 49 A 50 40 2 4 HP-1F SPARE 20 1 51 B 52 - -- 4 --- SPARE 20 1 53 C 54 20 1 SPARE SPARE 20 1 55 A 56 30 1 3 1 3 EF-P2 3600 HPAC 4 50 2 57 B 58 - -- 3 -- 3600 *** 4 * 59 C 60 - -- 3 - AS I 3600 HP-1D 4 50 2 61 A 1 62 20 1 3 IDF 1018-SPECIAL SYSTEMS 3600 *** 4 * * 63 B 64 20 1 3 IDF 2006 - SPECIAL SYSTEMS 2400 HP-2 4 30 2 65 C 66 20 1 3 1 IDF 2002 - SPECIAL SYSTEMS 2400 * 4 * 67 A 68 20 1 1 SPARE 2400 HP-3 4 30 2 69 B 70 20 1 SPARE 2400 * 4 * 71 C 72 20 1 SPARE SPARE 20 1 1 1 73 1 A 1 74 20 1 SPARE SPARE 20 1 1 1 75 1 B 1 76 20 1 SPARE SPARE 1 20 1 1 1 77 1 C 1 78 20 1 SPARE WAMIM MR 11A PANELBOARD SCHEDULE PANEL: K1 VOLTAGE: 208/120V PHASE:3 WIRE:4 AMPERE RATING: 400A SC RATING: 22KA.I.C. MAIN: MAIN LUG ENTRY: MOUNTING: FLUSH LOADS: AMPS VA LOAD TYPES: 1 = LIGHTING REMARKS: PHASE A: 379 45474 2 = RECEPTACLES 1.PROVIDE WITH FEED THROUGH LUGS PHASE B: 285 34173 3 = MISC PHASE C: 327 39210 4 = MOTOR TOTAL: 118857 5 = KITCHEN LOAD LOAD I AMPS/ I CKT CKT I AMPS/ LOAD LOAD (VA) I LOAD SERVED NOTE I TYPE I POLES I NO PHASE I NO I POLES I TYPE I NOTE LOAD SERVED (VA) 0 �� 5690 WALK-IN FREEZERICOOLER (4) 5 20 1 11 C 12 20 1 5 ICE MAKER (B15) 480 F_6 168 EVAPORATOR COIL FREEZER (5) 5 20 2 13 A 14 40 2 5 HIGH VOLUME COFFEE DISPENSER (Bi) 3120 168 ' 5 ` 15 B 16 ` 5 * 3120 07 1644 COMPRESSOR REMOTE, AIR COOLED(6) 5 20 3 17 C 18 20 1 5 REFRIGERATED CASE (B11) 48 soo A 1644 ' 5 ` 19 A 20 20 1 5 REFRIGERATED CASE (B7) 1440 720 1644 ' 5 ' 21 B 1 22 20 1 1 5 CASH REGISTER (1310) 180 926 9768 DOOR TYPE DISHMACHINE (29) 5 100 2 23 C 24 20 1 5 INDUCTION (614) 720 360 9768 ' 5 ` 25 A 26 20 1 5 INDUCTION (614) 720 1200 1440 FOOD PROCESSOR (40) 5 20 1 27 B 28 20 1 5 INDUCTION (614) 720 1000 480 FOOD SLICER (42) 5 20 1 29 C 30 20 1 5 SINGLE DOOR WINE COOLER (1320) 192 720 2064 LOW VOLTAGE COOK&HOLD OVEN(43) 5 25 1 31 A 32 20 1 5 SINGLE DOOR BEER COOLER (B21) 192 750 1920 CABINET, HOLDING (44) 5 20 1 33 B 34 20 1 SPARE 1680 ICED TEA BREWER (63) 5 20 1 35 C 36 20 1 SPARE 240 600 UNDERCOUNTER FREEZER (64) 5 20 1 37 A 38 20 3 3 EF-K1 1272 240 0 960 DOUBLE DECK OVEN (75) 5 20 1 39 B 40 * ` 1272 348 960 DOUBLE DECK OVEN (75) 5 20 1 41 C 42 ' ' 1272 348 800 TYPE 1 EXHAUST HOOD (76) 5 20 1 43 A 44 20 1 2 REC - KITCHEN OFFICE 540 800 TYPE 1 EXHAUST HOOD (76) 5 20 1 45 B 46 20 2 3 EF-K2 333 2400 240 FIRE SUPRESSION SYSTEM (77) 5 20 1 47 C 48 ' `"` 333 2400 AS 02000 112000 CHEFS COUNTER (80) 5 100 3 49 A 50 20 1 SPARE 3000 ' 5 ' 51 B 52 20 1 SPARE 3000 2000 * 5 ` 53 C 54 20 1 SPARE 360 SODA&ICE BEVERAGE DISPENSER (89) 5 20 1 55 A 56 20 1 SPARE 1800 BAG -IN -BOX DISPENSER (90) 5 20 1 57 B 58 20 1 SPARE 2640 00 3600 HIGH VOLUME COFFEE DISP. (92) 5 30 2 59 C 60 20 1 SPARE 2640 2640 3600 "** 5 ` ` 61 A 62 20 1 SPARE 888 REFRIGERATOR (94) 5 20 1 63 B 64 20 1 SPARE 500 1380 ICE CUBER (95) 5 20 2 65 C 66 20 1 SPARE 500 500 1380 "`" 5 ` ` 67 A 68 20 1 SPARE 1080 JUICE DESPENSER (96) 5 20 1 69 B 70 20 1 SPARE _ _A 07 327 ICE CREAM CABINET (97) 5 20 1 71 C 72 20 1 1 SPARE 600 FILTRATION SYSTEM (66.1) 5 20 1 73 A 74 20 1 SPARE 408 RANGE 6 BURNER W/GRIDDLE (71) 5 20 1 75 B 76 20 1 SPARE 720 REFRIGERATOR CHEF BASE (69) 5 20 1 77 C 78 20 1 SPARE ` 480 CONVECTION STEAMER(68) 5 20 1 79 A 80 20 1 SPARE 1296 PLANETARY MIXERS 5 20 1 81 B 82 20 1 SPARE 1 SPARE 20 1 83 C 84 20 1 SPARE J(/) LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% OVA G - DENOTES GFCI RATED BREAKER RECEPTACLES 13026 VA 220-44 10kVA @ 100%, ELSE @ 50% 11513 VA H - PROVIDE HACR TYPE BREAKER MISC. 11670 VA 220-60 100% 11670 VA MOTOR LARGEST MOT.: 3600 35976 VA 220-50 100%+ LARGEST x 25% 36876 VA KITCHEN # OF KIT. UNITS: 0 2200 VA 220-56 2200 VA TOTAL 175 A 173 A PANELBOARD SCHEDULE 20V PHASE: 3 WIRE:4 AMPERE RATING: 800A SC RATING: 42K A.I.C. MAIN: MAIN BREAK MOUNTING: SURFACE MPS VA PHASE A: 617 74098 PHASE B: 581 69754 PHASE C: 577 69215 TOTAL: 213067 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: NOTE #1 - PROVIDE "RED" HANDLE AND CONNECT TO FIRE ALARM SYSTEM NOTE #2 - DENOTES SHUNT TRIP BREAKER LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT AMPS/ P LOAD Y REC-CORRIDOR 6000 1 2 20 1 1 A 2 20 1 3 WH-1, WH-2, WH-3, FUTURE REC - CORRIDOR 5000 2 20 1 3 B - REC -CORRIDOR 40001 2 1 20 1 1 1 5 1 C 1 6 1 20 1 1 1 3 1 OF 2002 - SPECIAL SYSTEMS ,92o S1007 1080 REC - CORRIDOR 3000 1 1 2 1 20 1 1 1 7 1A 8 20 1 3 OF 2002 - SPECIAL SYSTEMS 1920 B 1 2 Y 9 720 FC-1A, 1B 1 1 4 1 15 1 2 1 11 D C 12 1 20 1 1 1 3 1 1 CP-1 1840 \SI 007 1920 OF 6011-SPECIAL SYSTEMS 1 3 20 1 1 1 27 B - 2 Q 1920 OF 6011-SPECIAL SYSTEMS 3 20 1 29 C 30 20 1 3 MDF 0003-SPECIAL SYSTEMS 1920 CAD ASI 007 1920 OF 5002 - SPECIAL SYSTEMS 3 20 1 31 A 32 20 1 3 MDF 0003 - SPECIAL SYSTEMS 1920 (VA) 1920 1920 1920 Q 1608 ASI 007 1920 IDF 5006-SPECIAL SYSTEMS 3 41 C 42 20 1 SPARE 1800 ;01 1920 1920 Q 1920 1920 ASI 007 1920 OF 4002 - SPECIAL SYSTEMS 3 20 1 49 A 50 15 2 4 FG2, 3, 4 720 720 720 Q 720 _CCD 00- 1 Skakc B 58 20 1 4 TF-1, EF-51ST, 2ND, 3RD, 4TH FLOOR 137 3so RR 2 20 1 59 C 60 20 1 4 -55 105500 altRE PARE 20 1 61 A 62 20 1 SPARE ASI 007 1920 IDF 3002-SPECIAL SYSTEMS 31 3 20 1 65 C 64 68 20 20 1 SPARE SPARE 6nn 1920 OF 5002-SPECIAL SYSTEMS 3 20 1 33 B 34 20 1 3 STOR. 4004-SPECIAL SYSTEMS 1920 1920 OF 5002-SPECIAL SYSTEMS 3 20 1 35 C 36 20 1 3 STOR. 3004-SPECIAL SYSTEMS 1920 540 REC: RECEPTION DESK 2 37 A 38 20 1 3 FIRE SMOKE DAMPERS 540 1920 OF 5006 -SPECIAL SYSTEMS 3 43 A2013 GENERATOR BLOCK HEATER 1600 B 46 20 1 3 GENERATOR BATTERY CHARGER 200 360 REC: DINING 1007 2 47 C 48 20 1 2 REC -GENERATOR SERVICE 180 1920 OF 4002 -SPECIAL SYSTEMS 3 20 1 51 B 52 - - 4 - 720 1920 OF 4006 -SPECIAL SYSTEMS 3 20 1 53 C 54 15 2 4 FGS, 6B 480 1920 OF 4006 -SPECIAL SYSTEMS 3 20 1 55 A 56 - - 4 - 480 ASI 007 S1 007 0 ASI-005 07 LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% 0 VA E - DENOTES EXISTING BREAKER TO REMAIN. RECEPTACLES 540 VA 220-44 10kVA @ 100%, ELSE @ 50% 540 VA N - DENOTES NEW BREAKER REQUIRED. MISC. 1605 VA 220-60 100% 1605 VA R - DENOTES TO REUSE EXISTING BREAKER. MOTOR LARGEST MOT.: OVA 220-50 100%+ LARGEST x 25% 5400 VA H - PROVIDE HACR RATED BREAKER KITCHEN # OF KIT. UNITS: 36 113835 VA 220-56 73993 VA S - PROVIDE SHUNT TRIP BREAKER TOTAL 322 A 226 A ANTHOLOGY OF EDMONDS LUMINAIRE DESCRIPTION MANUFACTURER CATALOG NUMBER LAMPS INPUT WATTS VOLTAGE MOUNTING NOTE COMMENTS EX1 EXIT SIGNS NORA NX-603-LED/R W/ WET LOCATION OPTION NEG-60 LED 2 MVOLT SURFACE EXIT B1 15" PUCK LIGHT THOMAS LIGHTING CL781434 WHITE FINISH LED 30 120 SURFACE COMMON AREA CORRIDORS B2 5" PUCK LIGHT ELK LIGHTING MLE1200-5-30, WHITE FINISH,3000K LED 9 120 SURFACE CORRIDORS, COMMON AREAS GL1 2x2 LAY -IN METALUX 22FPX42-L835 LED 41.5 MVOLT RECESSED OFFICES. KITCHEN, BOH GL2 2x2 LAY -IN METALUX 22FPX-21-L835 LED 21.5 MVOLT RECESSED OFFICES. KITCHEN, BOH PD1 DECORATIVE PENDANT KUZCO MINA PENDANT KZC610336 LED 8 120V PENDANT GREAT ROOM FIREPLACE PD2 DECORATIVE CHANELIER TECH LINGER 18-LIGHT CHANDELIER 70OLNG 18 B LED930 LED 80 120V PENDANT GREAT ROOM SITTING AREA PD3 DECORATIVE PENDANT TECH ORBEL ROUND PENDANT 700 TD OBLR R LED930 (1) LED BI-PIN G9 5 120V PENDANT GREAT ROOM RECEPTION PD4 DECORATIVE PENDANT ARTCRAFT LUGANO MULIT-LIGHT PENDANT ACRP313896 (3) 43W At LED 18 120V PENDANT MAIL PD5 DECORATIVE PENDANT NEMO CROWN PLANA LINEA PENDANT NIL457374 (10) 3W G9 LED 30 120V PENDANT BISTRO BANQUETTE PD6 DECORATIVE PENDANT PETITE FRITURE VERTIGO PENDANT BIS615410 (1) 53W A19 LED 6 24V PENDANT BISTRO BAR PD7 DECORATIVE PENDANT SERENA & LILY SANTA BARBARA PENDANT LA-H72-06 (1) 60W A19 LED 9 120V PENDANT DINING HOST PD8 DECORATIVE PENDANT SERENA & LILY SANTA BARBARA ROUND PENDANT LA-1182 (1) 60W A19 LED 9 120V PENDANT DINING HOST PD9 DECORATIVE PENDANT SERENA & LILY HEADLANDS PENDANT LA-1-1104-04 (1) 60W A19 LED 9 120V PENDANT DINING HOST PD10 DECORATIVE PENDANT POTTERY BARN FLORA RATTAN (1) 60W A19 LED 9 120V PENDANT DINING HOST PD11 DECORATIVE PENDANT dweLED LIGHTING LOLLI PENDANT UU572120 LED 6.5 120V PENDANT DINING NORTH FEATURE WALL PD12 DECORATIVE PENDANT MODERN FORMS COSMIC CHANDELIER MFR617499 (7) 7W LED 49 120V PENDANT DINING SOUTH FEATURE WALL PD13 DECORATIVE PENDANT AFX APEX PENDANT AFX APP1932LAJUDES-JT LED 42 120V PENDANT FAMILY PD14 DECORATIVE PENDANT AQUA CREATIONS TE LED PENDANTi AQUY19970 LED 13.5 120V PENDANT DIONFERENCE PD15 DECORATIVE PENDANT KENNETH COBONPUE C U C ME ROUND PENDANT HIV130273 (1) 60W A19 LED 9 120V PENDANT SALON RECEPTION DESK PD16 DECORATIVE PENDANT SHADES OF LIGHT FLEMING CEILING LIGHT FM20084 ZM (4) 60W El LED 36 120V PENDANT SALON PEDICURE STATION PD17 DECORATIVE PENDANT AQUA CREATIONS M LED PENDANT AQUY19940 LED 35 120V PENDANT COMMUNITY ROOM, ACTIVITY PD18 DECORATIVE PENDANT QUOIZEL ROMAIN MINI PENDANT RM11509EK (1) 75W A19 LED 12 120V PENDANT COMMUNITY ROOM KITCHEN ISLAND SM1 DECORATIVE FLUSH BETHEL INTERNATIONAL FLUSH MOUNT LG03 (3) A19 LED 20 120V FLUSH CORRIDOR GENERAL ACCENT SM2 DECORATIVE SEMI -FLUSH MINKA LAVERY SEMI -FLUSH MOUNT 4107-66 LED 14 120V SEMI -FLUSH CORRIDOR GENERAL ACCENT S1 4' WRAP METALUX 4VT2-LD5-4-DR-UNV-L835-CD1-WL-U LED 30 MVOLT SURFACE STAIRS S2 2' WRAP METALUX 2VT2-LD5-2-DR-UNV-L835-CD1-WL-U LED 17 MVOLT SURFACE ELEVATOR PIT S3 4'SUSPENDED KUZCO VEGA MINOR LED LINEAR BLACK KUZP266423 LED 32 MVOLT SUSPENDED SALON S4 4' STRIP METALUX 4SNLED-LD5-52SL-SLW-UNV-L835-CD1-U LED 52 MVOLT SURFACE JANITOR, IDF, ELEC, MECH, TRASH U2 RECESSED WALL WASH MARK SPRLED-LOP-I3FT-RLP-G9-80CRI-35K-400LMF-MINI-MVOLT LED 3.4/FT MVOLT RECESSED GREAT ROOM A J I U O L A T K 6 2 A 0& 0 V2 DECORATIVE VANITY ROGUE DECOR FIREFLY MULTI BATHROOM VANITY LIGHT ROG858700 LED 22.5 120V WALL RESTROOM 1019A & 1025A WD2 DECORATIVE SCONCE GEORGE KOVACS FABRIC WALL SCONCE (BRONZE W/ OFF-WHITE) UU169009 (1) A19 LED 6 120V SCONCE UNIT ENTRY UNIT LIGHTING UA 7" PUCK LIGHT ALLADIN KYD-08E-15-WH LED 15 120V SURFACE UNITS UB 13" PUCK LIGHT ALLADIN KYD-13E-25-WH LED 25 120V SURFACE UNITS Uc UNDER CABINET AMERICAN ALC2-18 LED 6 120V SURFACE UNITS UNDER CABINET UD 2' VANITY PROGRESS P2159-09 (3) 10OW A19 LED 36 120V WALL UNIT BATHROOMS LIE CLOSET LIGHT LITHONIA FMMCL 840 PIR LED 10.4 120V WALL UNIT CLOSETS OF EXTERIOR SCONCE NUVO 62-1142 LED 10 120V WALL UNITS EXTERIOR 1. Design is based on first named manufacturer. 2. Contractor shall provide and coordinate all fixture mounting accessories. 3. Contractor to coordinate final color with owner prior to ordering. 4. Contractor to coordinate finish colors of luminaires in wood ceiling with Architect. 5. Provide thower approved fixture equal to LIA fixture. ANTHOLOGY OF EDMONDS (OUTDOOR) LUMINAIRE DESCRIPTION MANUFACTURER CATALOG NUMBER LAMPS INPUT WATTS VOLTAGE MOUNTING NOTE COMMENTS RR1 RECESSED CAN LITHONIA LDN6 40/15 L06AR LSS MVOLT GZ10 LED 20.5 MVOLT RECESSED EXTERIOR BUILDING RR1 E RECESSED CAN W/ EMERGENCY LITHONIA LDN6 40/15 L06AR LSS MVOLT GZ10 EL LED 20.5 MVOLT RECESSED EXTERIOR BUILDING SL1 LED PARKING GARAGE LIGHT LITHONIA VCPG LED V4 P1 40K 80CRI T5M MVOLT SRM DDBXD LED 27 MVOLT SURFACE PARKING GARAGE SL1E LED PARKING GARAGE LIGHT W/ EMERGENCY LITHONIA VCPG LED V4 P1 40K 80CRI T5M MVOLT SRM E8WC DDBXD LED 27 MVOLT SURFACE PARKING GARAGE SM3 EXTERIOR MAIN ENTRY FRACTAL PCO10107-BC LED 67 MVOLT SURFACE EXTERIOR MAIN ENTRY SM4 EXTERIOR MAIN ENTRY FRACTAL PCO10105-BC LED 47 MVOLT SURFACE EXTERIOR MAIN ENTRY WD1 EXTERIOR SCONCE NUVO 62-1142 LED 10 120V SCONCE COURTYARD WD3 NOT USED WL1 EXTERIOR LED WALLPACK LITHONIA WSR LED P1 40K SR2 MVOLT PE DBLXD LED 19.6 MVOLT WALL PARKING GARAGE WL1E EXTERIOR LED WALLPACK W/ EMERGENCY LITHONIA WSR LED P1 40K SR2 MVOLT PE E20WC DLXD LED 19.6 MVOLT WALL EXTERIOR BUILDING L RFI-055 N 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SE WA 98101 20 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Ph one:208.288.2181 Project:21 AMA01 N 0 00 a P- Z z O = W Cn 70 LL z O0 0 z O Q> > J > J _� O -0 _ O z m W Z o U � D' Q Q\ N U a REVIS10 N DATE REASON FOR ISSUE 10/24/22 ASI 005 12/30/22 CCD 003 6 02/15/23 SMOKE CONTROL REVISIONS 03/09/23 ASI 007 ELECTRICAL SCHEDULES CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEETNUMBEIR "Oil E3.00 E co Cn Cn 0 PANELBOARD SCHEDULE PANEL 12A VOLTAGE: 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SC RATING: 22K A. I.0 MAIN: MAIN LUG ENTRY: MOUNTIN :SURFACE I LOADS AMPS VA PHASE A 0 0 PHASE B: 0 0 PHASE C: 0 0 TOTAL' 0 LOAD TYPES 1 = LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES ILOAD TYPE NOTE LOAD SERVED LOAD (VA) ROOM 208 IL-B1 3 125 2 1 A 2 125 2 3 ROOM 214 L-135 3 . 3 B 4 . 3 ROOM 210 L-136 3 125 2 5 C 6 125 2 3 ROOM 216 IL-Cl 3 . . 7 A 8 . . 3 ... ROOM 211 L-136 1 3 125 2 1 9 B 10 125 2 3 1 ROOM 218 1 L-C3 3 11 C 12 3 ... ROOM 212 L-131 3 125 2 13 A 14 125 2 3 ROOM 220 L-131 3 . . 15 B 16 . . 3 ... ROOM 213 IL-C4 3 125 2 17 C 18 125 2 3 ROOM 222 IL-A2 3 19 A 20 3 SPARE 1 20 1 21 B 22 125 2 3 1 ROOM 223 L-132 DEN SPARE 20 1 23 C 24 3 SPARE 20 1 25 A 26 125 2 3 ROOM 224 L-131 SPARE 20 1 27 B 28 3 SPARE 20 1 29 C 30 125 2 3 ROOM 225 L-132 SPARE 20 1 31 A 32 3 ... SPARE 20 1 33 B 34 125 2 SPARE SPARE 20 1 35 C 36 SPARE 20 1 37 A 3 �2 1 1 SPARE SPARE 20 1 1 1 39 B - �2 0 20 1 SPARE SPARE 1 1 1 41 C 42 20 1 1 1 SPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT. 0 VA 220-50 100% , LARGEST x 25% 0 VA KITCHEN OF KIT. UNITS 0 VA 220-56 0 VA ,TOTAL OA OA PANELBOARD SCHEDULE PANEL 12B VOLTAGE: 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SC RATING: 22K A.I.0 MAIN: MAIN LUG ENTRY: MOUNTING: SURFACE I LOADS AMPS VA PHASE A 0 0 PHASEB 0 0 PHASE C: 0 0 TOTAL: 0 LOAD TYPES 1 = LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO A POLES TYPE NOTE LOAD SERVED LOAD (VA) ROOM 230 L-132 3 125 2 1 A 2 125 2 3 ROOM 206 IL-C3 3 . . 3 B 4 . . 3 ... ROOM 232 L-136 3 125 2 5 C 6 125 2 3 ROOM 226 IL-C2 3 7 A 8 3 ROOM 234 L-136 3 125 2 9 B 10 125 2 3 ROOM 228 L-135 3 11 C 12 3 ... ROOM 236 L-136 3 125 2 13 A 14 20 1 SPARE 3 . 15 B 16 20 1 SPARE ROOM 238 L-136 3 125 2 17 C 18 20 1 SPARE 3 - - 19 A 20 20 1 ISPARE ROOM 240 L-136 3 125 2 21 B 22 20 1 SPARE 3 . 23 C 24 20 1 SPARE ROOM 201 L-513 3 125 2 25 A 26 20 1 SPARE 3 . . 1 27 B 28 20 1 SPARE ROOM 202 L-133 (TYPE A) 3 125 2 29 C 30 20 1 SPARE 3 31 A 32 20 1 SPARE ROOM 203 1 L-Al (TYPE A) 3 125 2 33 B 34 20 1 SPARE 3 35 C 36 1 20 1 1 1 SPARE ROOM 204 1 L-05 (TYPE A) 3 125 2 37 20 1 SPARE 3 39 �202 1 1 SPARE iSPARE --!�-�20 -1 � 4-1 1 SPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES' LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc, 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT.: 0 VA 220-50 100% , LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS 0 VA 220-56 0 VA TOTAL OA OA PANELBOARD SCHEDULE PANEL 13A VOLTAGE 208/120V PHASE: 3 WIRE: 4 AMPERE RATING 600A SC RATING: 22K A. I.0 MAIN: MAIN LUG ENTRY MOUNTING SURFACE I LOADS: AMPS VA PHASE A: 0 0 PHASE B: 0 0 PHASEC 0 0 TOTAL' 0 LOAD TYPES: 1 = LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) ROOM 308 IL-B1 3 125 2 1 A 2 125 2 3 ROOM 314 L-135 3 . . 3 B 4 . . 3 ROOM 310 L-136 3 125 2 5 C 6 125 2 3 ROOM 316 IL-Cl 3 . . - 7 A 8 . . 3 ROOM 311 L-137 3 125 2 9 B 10 125 2 3 ROOM 318 IL-C3 3 11 C 12 3 ROOM 312 L-131 3 125 2 13 A 14 125 2 3 ROOM 320 L-131 3 15 B 16 3 ... ROOM 313 IL-C4 3 125 2 17 C 18 125 2 3 ROOM 322 ILL-A2 3 19 A 20 3 SPARE 20 1 21 B 22 125 1 2 1 3 ROOM 323 L-132 DEN SPARE 20 1 23 C 24 . . 3 ... SPARE 20 1 25 A 26 125 2 3 ROOM 324 IL-B1 SPARE 20 1 1 27 1 B 28 . . 3 SPARE 20 1 29 C 30 125 2 3 ROOM 325 L-132 SPARE 20 1 31 A 32 3 ... SPARE 20 1 33 B 34 125 2 SPARE SPARE 20 1 35 C 36 SPARE 20 1 37 A 38 0 SPARE SPARE 20 11 32 B 40 M2 0 SPARE SPARE 1 20 1 1 �1 1 1 42 20 SPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT. 0 VA 220-50 100% - LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS: 0 VA 220-56 0 VA TOTAL OA OA PANELBOARD SCHEDULE PANEL: 13B VOLTAGE 208/120V PHASE: 3 WIRE: 4 AMPERE RATING 600A SC RATING: 22K A.I.0 MAIN: MAIN LUG ENTRY MOUNTING SURFACE I LOADS AMPS VA PHASE A: 0 0 PHASE B: 0 0 PHASE C 0 0 TOTAL 0 LOAD TYPES, 1 = LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE ILOAD TYPE AM POLES NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) ROOM 330 L-132 1 3 125 2 1 A 2 125 2 3 ROOM 306 IL-C3 3 . 3 B 4 . 3 ROOM 332 L-136 3 125 2 5 C 6 125 2 3 ROOM 336 IL-C2 3 . . 7 A 8 . . 3 ... ROOM 334 L-136 3 125 2 9 B 10 125 2 1 3 1 ROOM 328 L-135 3 . 11 C 12 . 3 ROOM 336 L-136 3 125 2 13 A 14 125 2 SPARE 3 . . 15 B 16 ROOM 338 L-136 3 125 2 17 C 18 20 1 SPARE 3 . . 19 A 20 20 1 SPARE ROOM 340 L-136 3 125 2 1 21 1 B 1 22 20 1 SPARE 3 . . 23 C 24 20 1 SPARE ROOM 301 L-132 3 125 2 25 A 1 26 20 1 SPARE 3 . 27 B 28 20 1 SPARE ROOM 302 L-133 3 125 2 29 C 30 20 1 SPARE 3 31 A 32 20 1 SPARE ROOM 303 IL -Al 3 125 2 33 B 34 20 1 SPARE 3 . 35 C 36 20 1 SPARE ROOM 304 IL -Al 3 125 2 37 A 38 20 1 SPARE 3 - 39 B 40 20 1 SPARE SPARE 20 1 1 41 C 42 20 1 SPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT. 0 VA 220-50 100% - LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS 0 VA 220-56 0 VA ITOTAL OA OA I PANELBOARD SCHEDULE PANEL 14A VOLTAGE: 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SC RATING: 22K A. I.0 MAIN: MAIN LUG ENTRY: MOUNTING SURFACE I LOADS AMPS VA PHASE A 0 0 PHASE B: 0 0 PHASE C: 0 0 TOTAL: 0 LOAD TYPES. 1 � LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS. SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS POLES CKT NO PHASE CK NO A POLES TYPE NOTE LOAD SERVED LOAD (VA) ROOM 408 IL-B1 3 125 2 1 A 2 125 2 3 ROOM 414 L-135 3 . . 3 B 4 . . 3 ... ROOM 410 L-136 3 125 2 5 C 6 125 2 3 ROOM 416 T-Cl 3 . 7 A 8 . 3 R30M 411 L-137 3 125 2 9 B 10 125 2 3 ROOM 418 1 L-C3 3 11 C 12 3 ... ROOM 412 L-131 3 125 2 13 A 14 125 2 3 ROOM 420 L-131 3 . 15 B 16 . 3 ROOM 413 IL-C4 3 125 2 17 C 18 125 2 3 ROOM 422 TA2 3 . . 19 A 20 . . 3 ... SPARE 1 1 20 1 21 1 B 22 125 2 3 1 ROOM 423 L-132 DEN SPARE 20 1 23 C 24 3 SPARE 20 1 25 A 26 125 2 3 ROOM 424 L-131 SPARE 20 1 27 B 28 3 ... SPARE 20 1 29 C 30 125 2 3 ROOM 425 L-132 SPARE 20 1 31 A 32 . 3 SPARE 1 1 20 1 33 1 B 34 125 2 SPARE SPARE 20 1 35 C 36 SPARE 20 -1 3-7 A 1 38 1 20 SPARE SPARE 0 420 1 39 B 1 40 1 20 E!' 1 1 SPARE SPARE - ----- � 1 41 C 1 42 1 20 1 SPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT.: 0 VA 220-50 100% , LARGEST x 25% 0 VA KITCHEN OF KIT. UNITS 0 VA 220-56 0 VA TOTAL OA OA '12A LOAD CALC' PANEL LOAD CALCULAT ON (OPTIONAL METHOD, N 220.80) UNIT CONNEC TED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILE 1-BDRM/1-BATH 10 24.2 242.4 ILF 2-BDRM/2-BATH 3 13 26.2 78.6 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 131.6 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 131.6 KVA 1 1 365 A '1213 LOAD CALC' PANEL LOAD CALCULAT ON (OPTIONA METHOD, NEC 220.80) UNIT CONNECTED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE (KVA) ILE 1-BDRM/1-BATH 10 24.2 242.4 ILE 2-BDRM/2-BATH 3 13 26.2 78.6 TEO T ]AL TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 131.6 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD71 131.6 KVA 1 1 365 A '13A LOAD CALC' PANEL LOAD CALCULAT ON (OPTIONA METHOD, NEC 220.80) UNIT CONNEC TED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILE 1-BDRM/1-BATH 10 24.2 242.4 1 1 ILE 2-BDRM/2-BATH 1 3 13 26.2 78.6 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 131.6 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 131.6 KVA 1 36 '1313 LOAD CALC' PANEL LOAD CALCULAT ON (OPTION METHOD, NEC 220.80) UNIT CONNECTED LOADS (PER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILF 1-BDRM/1-BATH 10 24.2 242.4 ILE 2-BDRM/2-BATH 3 13 26.2 78.6 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 131.6 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 131.6 KVA 1 365 A '14A LOAD CALC PANEL LOAD CALCULAT ON (OPTIONAL METHOD, N 220.80) UNIT CONNEC TED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILF 1-BDRM/1-BATH 10 24.2 242.4 ILE 2-BDRM/2-BATH 3 13 26.2 78.6 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41%__ OPTIONAL CALCULATED LOAD: 131.6 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 131.6 KVA 1 365 A PANELBOARD SCHEDULE PANEL: 14B VOLTAGE 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SCT7TING 22KA.I.0 MAIN: MAIN LUG ENTRY MOUNTING SURFACE I LOADS AMPS VA PHASE A: 0 0 PHASE B: 0 0 PHASEC 0 0 TOTAL' 0 LOAD TYPES 1 � LIGHTING 2- RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) ROOM 430 L-132 3 125 2 1 1 A 2 125 2 3 ROOM 406 IL-C3 3 3 B 4 3 ROOM 432 L-136 3 125 2 5 C 6 125 2 3 ROOM 426 IL-C2 3 7 A 8 3 ... ROOM 434 L-136 1 3 125 2 1 9 B 10 125 2 3 ROOM 428 L-135 3 11 C 12 3 ROOM 436 L-136 3 125 2 13 A 14 125 2 SPARE 3 15 B 16 ROOM 438 L-136 3 125 2 17 C 18 20 1 SPARE 3 19 A 1 20 20 1 SPARE ROOM 440 L-136 3 125 2 21 B 22 20 1 1 ISPARE 3 23 C 24 20 1 1 SPARE ROOM 401 L-135 3 125 2 25 A 26 20 1 SPARE 3 . 27 B 28 20 1 SPARE ROOM 402 L-133 (TYPE A) 3 125 2 29 C 30 20 1 SPARE 3 31 1 32 20 1 1 SPARE ROOM 403 IL -Al (TYPE A) 3 125 2 33 B 34 20 1 SPARE 3 . 35 C 36 20 1 ISPARE NA $201 ROOM 404 IL-05 (TYPE A) 3 125 2 37 A 38 ISPARE ��3 * . 39 B 40 20 1 ISPARE SPARE 20 1 41 C 42 20 1 ISPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT. 0 VA 220-50 100% - LARGEST x 25% 0 VA KITCHEN OF KIT. UNITS 0 VA 220-56 0 VA ITOTAL OA OA I PANELBOARD SCHEDULE PANEL 15A VOLTAGE 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SC RATING 22KA.I.0 MAIN: MAFN- LUG ENTRY MOUNTING SURFACE I LOADS: AMPS VA PHASE A: 0 0 PHASEB 0 0 PHASE C 0 0 TOTAL 0 LOAD TYPES: 1 = LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE NO POLES TYPE NOTE LOAD SERVED LOAD (VA) ROOM 508 L-131 3 125 2 1 A 2 125 1 2 1 3 ROOM 514 L-132 3 . 3 B 4 . 3 ROOM 510 L-136 3 125 2 5 C 6 125 2 3 ROOM 516 IL-Cl 3 7 A 8 3 ... ROOM 511 L-137 3 125 2 1 9 B 10 125 2 3 1 ROOM 518 IL-C3 3 11 C 12 3 ROOM 512 L-131 3 125 2 13 A 14 125 1 2 3 ROOM 520 L-131 3 . . 15 B 16 . . 3 ... ROOM 513 IL-C4 3 125 2 17 C 18 125 2 3 ROOM 522 IL-A2 3 19 A 20 3 SPARE 20 1 21 B 22 125 2 1 3 1 1 ROOM 523 L-132 DEN SPARE 20 1 23 C 24 3 ... SPARE 20 1 25 A 1 26 125 2 3 ROOM 524 L-131 SPARE 20 1 27 B 28 3 SPARE 20 1 29 C 30 125 2 3 ROOM 525 L-132 SPARE 20 1 31 A 32 3 ... SPARE 20 1 33 B 34 125 2 1 1 SPARE SPARE 20 1 35 C 36 * I I I *** SPARE 20 +2 1 37 A 38 20 1 SPARE SPARE 0 1 3 E pc� 10 1 �2 1 ISPARE SPARE 20 1 4 1 4� 20 1 ISPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT. 0 VA 220-50 100% + LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS: 0 VA 220-56 0 VA TOTAL OA OA PANELBOARD SCHEDULE PANEL 15B VOLTAGE: 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SC RATING: 22K A. I.0 MAIN: MAIN LUG ENTRY MOUNTING: SURFACE i LOADS: AMPS VA PHASE A 0 0 PHASE B 0 0 PHASE C: 0 0 TOTAL: 0 LOAD TYPES: 1 = LIGHTING 2- RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) ROOM 530 L-132 3 125 2 1 A 2 125 2 ROOM 506 IL-C3 3 . . 3 B 4 ROOM 532 L-136 3 125 2 5 C 6 125 2 ROOM 526 IL-C2 3 7 A 8 ROOM 534 L-136 3 125 2 9 1 B 10 125 2 ROOM 528 L-135 3 . . 11 C 12 ROOM 536 L-136 3 125 2 13 A 14 125 2 SPARE 3 . . 15 B 16 ROOM 538 L-136 3 125 2 17 C 18 20 1 SPARE 3 19 A 20 20 1 ISPARE ROOM 540 L-136 3 125 1 2 1 21 1 B 22 20 1 SPARE 3 23 C 24 1 20 1 SPARE ROOM 501 L-135 3 125 2 25 A 26 20 1 SPARE 3 27 B 28 20 1 SPARE ROOM 502 L-133 3 125 2 29 C 30 20 1 SPARE 3 . . 31 A 32 20 1 1 1 SPARE ROOM 503 IL -Al 3 125 2 33 B 34 20 1 SPARE 3 . . 35 C 36 20 1 SPARE ROOM 504 IL-05 25 37 3 20 1 SPARE ff3 3] .0 �2L4 39 �!B 40 � 20 1 SPARE SPARE I C 42 20 1 SPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT.: 0 VA 220-50 100% - LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS: 0 VA 220-56 0 VA ITOTAL OA OA I PANELBOARD SCHEDULE PANEL: 16A VOLTAGE 208/120V PHASE: 3 WIRE: 4 AMPERE RATING: 600A SC RATING 22KA.I.0 MAIN: MAIN LUG ENTRY: MOUNTING SURFACE I LOADS AMPS VA PHASE A: 0 0 PHASE B: 0 0 PHASE C 0 0 TOTAL 0 LOAD TYPES 1 LIGHTING 2 RECEPTACLES 3 MISC 4 MOTOR 5 KITCHEN REMARKS SEE LOAD CACULATIONS, THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AM S/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) ROOM 611 L-136 3 125 2 1 A 1 2 125 1 2 1 3 ROOM 620 IL-B1 3 3 B 4 3 ROOM 612 IL-B1 3 125 2 5 C 6 125 2 3 ROOM 622 IL-A2 3 7 A 8 3 ... ROOM 613 IL-C4 3 125 2 9 B 10 125 2 3 ROOM 623 L-132 3 11 C 12 3 ROOM 614 L-135 3 125 2 13 A 14 125 2 3 ROOM 624 L-131 3 15 B 16 3 ... ROOM 616 IL-Cl 3 125 2 17 C 18 125 2 3 ROOM 625 BL-B2 3 19 A 20 3 ROOM 618 IL-C3 3 125 2 21 B 22 125 2 SPARE 3 23 C 24 SPARE 20 1 1 1 25 A 26 20 1 SPARE SPARE 20 1 27 B 28 20 1 SPARE SPARE 20 1 29 C 30 20 1 SPARE SPARE 20 1 31 A 32 20 1 SPARE SPARE 20 1 33 B 34 20 1 SPARE SPARE 0 1 35 C 36 20 1 1 1 ISPARE SPARE J12 20 1 37 A 38 20 1 SPARE SPARE 20 B 4 12 AR SPARE 0 C 4 s�7 EE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT.' 0 VA 220-50 100% � LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS' 0 VA 220-56 0 VA ITOTAL OA OA I PANELBOARD SCHEDULE PANEL 16B VOLTAGE: 208/120V PHASE: WIRE: 4 AMPERE RATIRG: 600A SC RATING: 22K A. I.0 MAIN: MAIN LUG ENTRY: MOUNTING: SURFACE I LOADS: AMPS VA PHASE A 0 0 PHASE B 0 0 PHASE C: 0 0 TOTAL: 0 LOAD TYPES: 1 = LIGHTING 2= RECEPTACLES 3 = MISC 4 = MOTOR 5 = KITCHEN REMARKS: SEE LOAD CACULATIONS, THIS SHEET LOA (VA) LOAD SERVED NOTE TYPE POLES NO PHASE NO POLES YPE NOTE LOAD SERVED (VA) ROOM 636 L-136 3 125 2 1 A 2 125 2 3 ROOM 632 IL-B 3 3 B 4 3 ... ROOM 638 L-136 3 125 2 5 C 6 125 2 3 ROOM 634 L-136 3 7 A 8 1 3 ROOM 640 L-136 3 125 2 9 B 10 125 2 SPARE 3 11 C 12 ROOM 601 IL-B5 3 125 2 13 A 14 1 20 1 1 1 SPARE 3 . 15 B 16 20 1 SPARE ROOM 602 L-133 (TYP A) 3 125 2 17 C 18 20 1 SPARE 3 . . 19 A 20 20 1 SPARE I ROOM 603 IL -Al (TYPE A) 1 3 125 2 21 B 22 20 1 SPARE 3 . 23 C 24 20 1 SPARE ROOM 604 IL-Cl (TYPE A) 3 125 2 25 1 A 26 1 20 1 1 ISPARE 3 . . 27 B 28 20 1 ISPARE ROOM 626 IL-C2 3 125 2 29 C 30 20 1 SPARE 3 . 31 A 32 20 1 SPARE ROOM 628 L-135 1 3 125 2 33 B 34 20 1 SPARE 35 C 36 20 1 SPARE ROOM 630 L-132 1 25 2 37 1 32 2 1 SPARE . 39 . 1 �O 1 2 0 1 1 PARE SPARE 20 1 41 1 C 1 42 1 20 1 1 1 1 ISPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES LIGHTING 0 VA 210-19 125% 0 VA H - PROVIDE HACR RATED BREAKER RECEPTACLES 0 VA 220-44 1OkVA @ 100%, ELSE @ 50% 0 VA misc. 0 VA 220-60 100% 0 VA MOTOR LARGEST MOT.: 0 VA 220-50 100% , LARGEST x 25% 0 VA KITCHEN # OF KIT. UNITS: 0 VA 220-56 0 VA ITOTAL OA OA '1413 LOAD CALC' PANEL LOAD CALCULAT ON (OPTION METHOD, NE 220.80) UNIT CONNEC TED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILE 1-BDRM/1-BATH 10 24.2 242.4 ILE 2-BDRM/2-BATH 3 13 26.2 78.6 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 131.6 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 131.6 KVA 1 1 365 A '15A LOAD CALC PANEL LOAD CALCULAT ON (OPTIONAL METHOD, N 220.80) UNIT CONNEC TED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILF 1-BDRM/1-BATH 10 24.2 242.4 ILF 2-BDRM/2-BATH 3 13 26.2 78.6 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 131.6 KVA --7 OPTIONAL CALCULATED LOAD: 131.6 KVA 1 365 A '1513 LOAD CALC' PANEL LOAD CALCULATION (OPTION METHOD, NE 220.80) UNIT CONNEC TED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILE 1-BDRM/1-BATH 10 24.2 242.4 1 ILF 2-BDRM/2-BATH 3 13 26.2 -- 78.6 TOTAL PANEL CONNECTED UNIT LOAD: 321.1 KVA DIVERSITY FACTOR: o� 41% =131.6KVA OPTIONAL CALCULATED LOAD: CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD� 131.6 KVA 1 365 A I I I I I I - '16A LOAD CALC' PANEL LOAD CALCULAT ON (OPTION METHOD, NEC 220.80) UNIT CONNECTED LOADS (PER NEC 220.82 (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) I ILF 1-BDRM/1-BATH 8 24.2 193.9 1 ILE 2-BDRM/2-BATH 2 10 26.2 52.4 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 246.4 KVA DIVERSITY FACTOR: 43% OPTIONAL CALCULATED LOAD: 105.9 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 105.9 KVA 294 A I I I I I . I '1613 LOAD CALC' PANEL LOAD CALCULAT ON (OPTIONA METHOD, N 220.80) UNIT CONNECTED LOADS (F ER NEC 220.8z (C)) UNIT TYPE # OF UNITS UNIT LOAD (KVA) LOAD BY UNIT TYPE(KVA) ILF 1-BDRM/1-BATH 10 24.2 242.4 ILF 2-BDRM/2-BATH 2 12 26.2 52.4 TOTAL: TOTAL PANEL CONNECTED UNIT LOAD: 294.8 KVA DIVERSITY FACTOR: 41% OPTIONAL CALCULATED LOAD: 120.9 KVA CORE CALCULATED LOAD KVA OPTIONAL CALCULATED LOAD: 120.9 KVA 1 336 A PANELBOARD SCHEDULE PANEL: ILF-1Bd1Bth/Studio VOLTAGE: 208/120V PHASE: 1 1 VIARE; 3 --TAMPERE RATING: 125A SC RATING: 1 OK A.I.C. MAIN: MAIN LUG OR MAIN BREAKER ENTRY: MOUNTING: FLUSH OR SURFACE I LOADS: AMPS VA PHASE A: 118 14110 PHASE B 118 14200 TOTAL* 28310 LOAD TYPES: 1 = LIGHTING 2 = RECEPTACLES 3 = MISC 4 - MOTOR 5 - KITCHEN REMARKS: SEE LOAD CALCS THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AM S/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) 600 LIGHTS, EFs, DBF-1 1080 REC-LIVING ROOM A 2 15 1 3 B 4 20 1 3 H HEAT/LIGHT/FAN IN BATH 1500 1500 REC-BATH 2 20 1 :E::: A 6 20 2 3 H LIVING ROOM VTAC-2 1400 4000 RANGE 2 40 2 7 B 3 H 1400 4000 2 - - 9 A 10 20 1 2 A REC-KITCHEN #2 360 1500 MICROWAVE A 2 20 1 11 B 12 15 1 2 A REC-BEDROOM 720 1500 REC-KITCHEN #1 2 20 1 13 A 14 20 1 3 H BDRM EWH-1 750 1500 CLOTHES WASHER A 2 20 1 15 B 16 20 1 SPARE 2500 CLOTHES DRYER 2 30 2 17 A 18 20 1 SPARE 2500 2 - - 19 B 1 20 1 20 1 1 1 SPARE SPARE -TO 1 21 A 22 1 20 1 1 1 SPARE SPARE 20 1 . 11 . I I LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 600 VA 210-19 125% 750 VA A - PROVIDE AFCI TYPE CIRCUIT BREAKER RECEPTACLES 22660 VA 220-44 16330 VA B - PROVIDE DBF-1 ON I ST & 2ND FLR UNITS ONLY misc. 5050 VA 220-60 100% 5050 VA H - PROVIDE HACR RATED BREAKER MOTOR LARGEST MOT. 0 VA 220-50 100% , LARGEST x 25% 0 VA KITCHEN #OF KIT. UNITS: 0 VA 220-56 0 VA TOTAL 118 A 92A APARTMENT TYPE: I 'ILq-1 Bd1 Bth Load jCaIc' I I 'ILF-lBdlBth Load CaIc' (OPTIONAL METHOD, NEC 220.30) CONNECTED LOAD VA (A) 1TWO SMALL APPLIANCE CIRCUITS 3000 LAUNDRY BRANCH CIRCUIT 1500 2. GENERAL LIGHTING & SQ.FT: 526 1578 RECEPTACLES (3 VA/ SQ. FT.) 3. APPLIANCES: MICROWAVE 1500 RANGE 8000 DISHWASHER 864 4. MOTORS GARBAGE DISPOSAL 0 SUBTOTAL: 21442 FIRST 10KVA g 1U97b- 10000 REMAINDER @ 40% 4577 SUBTOTAL: 14577 (B) LARGEST OF HEATING AND A/C 2800 TOTAL LOAD: 17377 VA 1 1 84 AMPS 1A PANELBOARD SCHEDULE PANEL: ILF-2Bd2Bth VOLTAGE: 208/120V PHASE: 1 WIRE: 3 AMPERE RATING: 125A SC RATING: 10K A.I.C. MAIN: MAIN LUG OR MAIN BREAKER ENTRY: MOUNTING: FLUSH OR SURFACE I LOADS: AMPS VA PHASE A* 153 18398 PHASE B* 147 17600 TOTAL 35998 LOAD TYPES: 1 - LIGHTING 2 - RECEPTACLES 3 - MISC 4 - MOTOR 5 - KITCHEN REMARKS: SEE LOAD CALCS THIS SHEET LOAD (VA) LOAD SERVED NOTE LOAD TYPE AMPS/ POLES CKT NO PHASE CKT NO AMPS/ POLES LOAD TYPE NOTE LOAD SERVED LOAD (VA) 768 LIGHTS, Efs, DBF-1 A,B 1 15 1 1 A 2 20 1 2 REC-DISHWASHER/DISPOSAL 1500 1080 REC-LIVING ROOM A 2 15 1 3 B 4 20 1 3 HEAT/LIGHT/FAN IN BATH 1500 N-'V- 1500 REC-BATH 2 20 1 5 6 30 2 3 H LIVING ROOM VTAC-3 2050 4000 RANGE 2 40 2 7 8 - - 3 H 2050 4000 --- 2 - - 9 A 10 20 1 2 A REC-KITCHEN #2 360 1500 MICROWAVE A 2 20 1 1 11 B 12 15 1 2 A REC-BEDROOM 720 1500 REC-KITCHEN #1 A 2 20 1 13 A 14 20 1 3 H BDRM EWH-1 750 1500 CLOTHES WASHER A 2 20 1 15 B 16 20 1 SPARE 2500 -- 2 - - 19 B 20 20 1 3 1 HEAT/LIGHT/FAN IN BATH 1500 1250 BEDRM PTAC-1 H 3 20 1 21 A 22 20 1 2 REC-BATH 1500 1250 --- H 3 20 1 23 B 24 20 1 ISPARE LOADING BY TYPE CONNECTED NEC CODE DEMAND FACTOR DEMAND NOTES: LIGHTING 768 VA 210-19 125% 960 VA A - PROVIDE AFCI TYPE CIRCUIT BREAKER RECEPTACLES 24880 VA 220-44 1OkVA @ 100%, ELSE @ 50% 17440 VA B - PROVIDE DBF-1 ON 1 ST & 2ND FLR UNITS ONLY misc. 10350 VA 220-60 100% 10350 VA H - PROVIDE HACR RATED BREAKER MOTOR LARGEST MOT. 0 VA 220-50 100% , LARGEST x 25% 0 VA KITCHEN #OF KIT. UNITS: OVA 220-56 0 VA TOTAL 150 A 120 A APARTMENT TYPE� I 'ILq-2Bd2Bth Load jCaIc' I I 'ILF-213IIJ213th Load CaIc' (OPTIONAL METHOD, NEC 220.30) CONNECTED LOAD VA (A) 13WO SMALL APPLIANCE CIRCUITS 3000 LAUNDRY BRANCH CIRCUIT 1500 2. GENERAL LIGHTING & SQ.FT: 750 2250 RECEPTACLES (3 VA/ SQ. FT.) 3. APPLIANCES: MICROWAVE 1500 RANGE 8000 DRYER 5000 DISHWASHER 864 4. MOTORS GARBAGE DISPOSAL 0 SUBTOTAL: 22114 F )% 10000 REMAINDER @ 40% 4846 SUBTOTAL: 14846 (B) LARGEST OF HEATING AND A/C 4100 TOTAL LOAD: 18946 VA 91 AMPS A5 - G A Z Z 3 /0 L 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 1 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ANKROM MOISAN ARCHITECTS, INC. ��12 1p�� =it Mw DC EN13INEERIN13 Careful listening. Dynamic solutions. www.dcengineering.net Phone:208.288.2181 Project:21AMA01 (0 04 0 00 0) Cl) 0 z (D z 0 LU (6 0 z 0 0 LL] z > 0 01-0 CY) 0 C'4 z _j LU 0 z C:) W 04 0 LU 04 REVISIO N DATE REASON FOR ISSUE 5 03/14/22 Construction Set ELECTRICAL SCHEDULES N TRU TI N SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E3.01 COPPER ALUMINUM CONDUCTOR/ RACEWAY TAG Conduit Conductor Conduit Conductor [2000S] * EA. W/4#400KCM I L * EA. W/4#500KCM I L [2500S] * EA. W/4#500KCM I L * EA. W/4#600KCM I L [3000S] * EA. W/4#500KCM I L * EA. W/4#600KCM I L [4000S] * EA. W/4#750KCM I L * EA. W/4#1000KCM I L [100N] 1-1/2 If 4#21 1#8G 2rr 4#1/0, 1#6G [125N] 211 4#1, 1#6G 211 4#1/0, 1#4G [150N] 2rr 4#1/0, 1#6G 2rr 4#2/0, 1#4G [175N] 211 4#2/0, 1#6G 2-1/211 4#3/0, 1#4G [200N] 2-1/2 If 4#3/0, 1#6G 2-1/2 If 4#4/0, 1#4G [225N] 2-1/211 4#4/0, 1#4G 1 31 4#250KCMIL, 1#2G [250N] 3rr 4#250KCMIL, 1#4G 3rr 4#350KCMIL, 1#2G [300N] 311 4#300KCMIL, 1#4G 3-1/211 4#400KCMIL, 1#2G [350N] 3-1/211 4#400KCM I L, 1#3G 4rr 4#600KCM I L, 1#1G [400N] 3-1/2 If 4#500KCMIL, 1#3G 2 2-1 2rr EA. W/4#4/0, 1#1G [500N] (2)2-1/2 If EA. W/4#4/0, 1#2G (2)3 If EA. W/4#300KCMIL, 1#1/OG [600N] (2)3 If EA. W/4#300KCM I L, 1#1G (3)3 If EA. W/4#250KCM I L, 1#2/OG [800N] 2 3-1 2rr EA. W/4#500KCMIL, 1#1/OG 3 311 EA. W/4#350KCMIL, 1#3/OG [1000N] (3)3-1/2 If EA. W/4#400KCMIL, 1#2/OG (3)4 If EA. W/4#600KCMIL, 1#4/OG [1200N] 4 311 EA. W/4#350KCMIL, 1#3/OG (4)4 It EA. W/4#500KCMIL, 1#250G [1600N] (5)3-1/2 If EA. W/4#400KCMIL, 1#4/OG (5)4 If EA. W/4#600KCMIL, 1#350G [2000N] 6 3-1 2rr EA. W/4#400KCMIL, 1#250G (7)4 It EA. W/4#500KCMIL, 1#40OG [2500N] (7)4 If EA. W/4#500KCMIL, 1#350G (8)4 If EA. W/4#600KCMIL, 1#60OG [20] 3/4rr 3#121 1#12G 3/4rr 3#10, 1#10G [30] 3/4rr 3#101 1#10G 3/4rr 3#8, 1#8G [40] 3/4rr 3#8, 1#10G 1rr 3#6, 1#8G [50] 1rr 3#6, 1#10G 1-1/4 It 3#4, 1#8G [60] 1rr 3#6, 1#10G 1-1/4 If 3#41 1#8G [70] 1-1/4 It 3#4, 1#8G 1-1/4 It 3#3, 1#6G [80] 1-1/4 It 3#3, 1#8G 1-1/4 It 3#2, 1#6G [90] 1-1/4 If 3#21 1#8G 1-1/2 If 3#11 1#6G [100] 1-1/4 It 3#2, 1#8G 1-1/211 3#1/0, 1#6G [125] 1-1/4 If 3#11 1#6G 2rr 3#1/0, 1#4G [150] 1-1/211 3#1/0, 1#6G 211 3#2/0, 1#4G [175] 2rr 3#2/0, 1#6G 2rr 3#3/0, 1#4G [200] 211 3#3/0, 1#6G 2-1/211 3#4/0, 1#4G * Coordinate with PNM. Final conduit size must be coordinated with PNM prior to purchase and installation. 0 ry Q O O Q co_ J Z m z � Q 2 Q � (D J F- w C7LLI w w Z Z w Z Q F Cf) 0 o O (D 0 ow Oa_ LLI o> C) ch LU *k� coQQ N F MO MO ►% #6 BARE- -- FINISHED COPPER FLOOR ff7 � (3)8'x5/8" ROD ELECTRODES GROUNDING DETAIL KEYED NOTES- 1. LIFER GROUND TO BE 20' OF #4 AWG COPPER OR 1/2" MINIMUM DIAMETER STEEL REINFORCING BAR PER NEC ARTICLE 250.52. GROUNDING DETAIL L N T S D E co M 1J J 11 C J 0 GROUNDING BUSHING TYPICAL LINO %j LIFER GROUND #4 COPPER 20' UFER GROUNDING DETAIL GENERAL NOTES: 1. ALL CONDUCTORS SHALL BE IN EMT CONDUIT UNLESS NOTED OTHERWISE. ALL CONDUITS SHALL HAVE A GROUNDING BUSHING AT EACH END. 2. ALL CONNECTIONS SHALL BE EXOTHERMIC WELD, LISTED PRESSURE CONNECTORS, LISTED CLAMPS OR OTHER LISTED MEANS. COORDINATE WITH SNOHOMISH COUNTY PUD ELECTRIC REQUIREMENTS FOR CONDUIT, TRENCHING AND BACKFILL. CONDUCTORS PROVIDED BY SNOHOMISH COUNTY PUD SNOHOMISH COUNTY PUD ELECTRIC CABINET MDP-1 DEMAND LOAD CALCULATION CONNECTED CALCULATIONS: Non dwelling space calculated demand load= LIGHTING 20425 RECEPTACLE 55979 misc. 321268 MECHANICAL/MOTOR 111634.1 KITCHEN 99072 ELEVATOR #2 437320 CONCRETE PAD/VAULT PER SNOHOMISH COUNTY PUD REQUIREMENTS PROVIDE UNDER THIS CONTRACT, OLD CASTLE, INC OR EQUAL. SNOHOMISH COUNTY PUD TRANSFORMER SEE SITE PLAN EMERGENCY GENSET. MUST COME ONLINE WITHIN 10 SECONDS SERVICE RECEPTACLE I G_ SP1-6 3/4"C. 13 12 I — — 014 GROUND PER NEC 250 BATTERY CHARGER SP1-4 1"C. ENGINE BLOCK HEATER, SP1-2 QAS I-001.1 30OKW GENERATOR 208V 3 PHASE, 4W 60Hz, DIESEL. FUEL IN SUB -BASE FUEL TANK PROVIDED SECONDARY CONNECTION O CABINET, SCC-1. LO1O14 Non Dwelling Calculated Demand Load is arrived upon by summing the following: Lighting Load @ 125% 401585 VA 1 ST 1 OkVA of Rec. @ 100% remainder @ 50% 50979 VA Miscellaneous Loads @ 100% 321268 VA Largest Motor @ 125% 54150 Remainder of Motor Load @ 100% 111634 VA Kitchen @ 65% 64397 VA SUM of non living space calculated demand load 1004013 VA Load kVA 1004 AMP 2787 TOTAL DEMAND LOAD AT 120/208V 3-PHASE KVA 1004 AMPS 2787 1-1/2" CONDUIT FOR CONTROLAND MONITORING 13 O SIGNALS 600 AMP, 3 POLE LIFE SAFETY AUTOMATIC TRANSFER SWITCH #ATS1 NEMA 1 [400N] I [400N] 16 I GROUND PER NEC [800N] I 800N] 800 AMP, 3 POLE — STANDBY AUTOMATIC TRANSFER SWITCH #ATS2 NEMA 1 GROUND PER NEC F [400N] [800N] IO �0 TERMINAL CABINET [3000S] )TO MDP-2 (REFER TO DWG. F4 ni *** PROVIDED CABLE TRAY RACEWAY, GROUND ROD AND CONDUCTOR TO NEUTRAL BUS AND CASE GROUND, PER SNOHOMISH COUNTY PUD REQUIREMENTS. 3000A 1 18 MAIN 3P KR I OI NEUT.BUS 400A 3P FIRE/LIFE SAFETY EMERGENCY PANEL LOCATED IN MAIN ELECTRICAL RM. 0002 STANDBY BACKUP POWER PANEL PANEL 400A PANEL SP1 800A MCB I MAIN ELEC. RM. 0002 KEYED NOTES PANEL PANEL1L PANEL PANEL PP 1P 3P 600A 100A 200A 100A T [600N] I [100N] 200N] T [100N] 800A � 600A ") 100A 3P 3P i 3P GROUND PER NEC 250. RE: DETAIL ON SHEET Fri nn ASI-005 PANEL PANEL PANEL ELEVATOR #2 6L 6P 6M1 M 100A 200A 400A F [200N] [200N] [400N] [100N] FI #168 Remote Annunciator Panel Location 1-005 200A 3P 100A 3P 1 200A 200A 3P 40 3P 100A ST SPACE 3P D 3P 3P 3000 AMP RATED BUS OMAIN DISTRIBUTION PANEL #1 (MDP-1) 3000A, 208Y/120 VOLT, 3 PHASE, 4 WIRE 100,000 AIC RATED NEMA 1 RATED PANEL MDP-1 ONE -LINE POWER DISTRIBUTION DIAGRAM SCALE: N.T.S. ASI-005 GENERAL NOTES: A. SNOHOMISH COUNTY PUD REQUIRES GENERATORS TO BE CONNECTEDUSING A PERMANENTLY INSTALLED OPEN - TRANSITION (BREAK -BEFORE -MAKE) TRANSFER SWITCH PER PAGE 63 OF THE PNM ELECTRICAL SERVICE GUIDE. THE TRANSFER SWITCH MUST BE USED TO DISCONNECT ALL UNGROUNDED CONDUCTORS CONNECTED TO THE PGE SYSTEM PRIOR TO CONNECTING THE GENERATOR TO THE CUSTOMER'S ELECTRICAL SYSTEM. B. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR TRENCHING, BACKFILLING, COMPACTION CONDUIT, TRANSFORMER PADS OR VAULTS, AND ANY OTHER REQUIREMENTS TO COMPLETE THE UNDERGROUND SERVICE PER SNOHOMISH COUNTY PUD SERVICE REQUIREMENTS MANUAL. KEYED NOTES 1. 4 INCH HIGH CONCRETE HOUSEKEEPING PAD UNDER SWITCHBOARD. COORDINATE WITH GENERAL CONTRACTOR. 2. CURRENT TRANSFORMER/TERMINAL CABINET PER THE MOST RECENT EDITION OF SNOHOMISH COUNTY PUD SERVICE REQUIREMENTS. 3. CONFIRM UTILITY TRANSFORMER IMPEDANCE. UTILITY TO PROVIDE AVAILABLE FAULT CURRENT. 4. ALL PRIMARY AND SECONDARY CONDUIT, TRENCHING AND BACKFILL, INCLUDING PULL VAULTS, AND CONDUCTORS ARE UNDER THIS CONTRACT, TO INCLUDE TERMINAL LUGS FOR UTILITY CONNECTION. VERIFY REQUIREMENTS WITH SNOHOMISH COUNTY PUD. TRENCHING AND BACKFILL BY GENERAL CONTRACTOR. COORDINATE WITH GENERAL CONTRACTOR. 5. SERVING - UTILITY - SNOHOMISH COUNTY PUD. COORDINATE ALL REQUIREMENTS OF SNOHOMISH COUNTY PUD. REFER TO INSTALLATION REQUIREMENTS MANUAL LATEST EDITION. 6. UTILITY SERVICE FEEDERS WITHIN BUILDING FOOTPRINT TO BE INSTALLED BELOW SLAB, ENCASED WITH MINIMUM OF 6" CONCRETE ABOVE. VERIFY WITH AHJ. 7. USE SERIES RATED SWITCHES, BREAKERS AND RELATED EQUIPMENT. USE NEXT HIGHER AIC RATING THAN CALCULATED. 8. INSTALL WARNING RIBBON PER NEC. 9. VERIFY MOTOR SIZE, REQUIRED CIRCUIT BREAKER AND CONDUCTOR SIZE WITH ELEVATOR MANUFACTURER PRIOR TO ORDERING SWITCH GEAR AND CONDUCTOR MATERIAL. PER NEC. 10. USE COPPER CONDUCTORS AT ELEVATOR AS REQUIRED BY ELEVATOR MANUFACTURER. USE FULL SIZE GROUND. 11. STANDBY DIESEL GENERATOR, BASIS OF DESIGN: CUMMINS MODEL DFEJ 60HZ, 300 KW RATED, 208 VOLT, 3 PHASE, BASE MOUNT UL142 FUEL TANK, 693 GAL. NOMINAL 24 HOUR RUN TIME @ 100% LOAD. PROVIDE SEISMIC ATTACHMENT TO CONCRETE BASE, FUEL FILTER, ENGINE BLOCK HEATER, 10 AMP BATTERY CHARGER, REMOTE CONTROL PANEL AND EMERGENCY STOP, WITH LOW FUEL WARNING. PROVIDE WITH (1) 800 AMP AND (1) 600 AMP CIRCUIT BREAKER. PROVIDE WITH REMOTE ANNUNCIATOR AND ALARM HORN WITH (2) GENERATOR AUTOMATIC TRANSFER SWITCHES. AUTOMATIC TRANSFER SWITCH TO BE GROUNDED PER NEC ART. 250.30. 12. CONCRETE BASE FOR GENERATOR TO BE DESIGNED BY STRUCTURAL ENGINEER TO MATCH GENERATOR BEING USED. CONCRETE PAD DESIGNED AND PROVIDED BY OTHERS. COORDINATE WITH GENERAL CONTRACTOR AND ARCHITECT. 13. GENERATOR CONTROL WIRING METHODS SHALL BE INSTALLED PER NEC 695.14. 14. BOND GENERATOR CASING TO GROUND. DO NOT BOND EQUIPMENT NEUTRAL/GROUND AT ENGINE GENERATOR. 15. NOT USED. 16. WHERE ROUTED THRU THE BUILDING, THE CONDUCTORS SHALL BE PROTECTED 2 HOUR FIRE RATED PER NEC. 17. PROVIDE ELEVATOR DELAY RELAY TO BE INSTALLED IN THE ATS WHICH SERVES THE ELEVATORS. PROVIDE THREE (3) CONDUCTORS FROM THE ATS TO THE ELEVATOR MOTORS PER MANUFACTURER'S RECOMMENDATIONS. 18. PROVIDE BREAKER WITH ARC ENERGY REDUCTION PER NEC 240.87. 19. PROVIDE EATON ELEVATOR CONTROL ES SWITCH DISCONNECT, COORDINATE REQUIREMENTS WITH ELEVATOR SUPPLOER FOR COMPLETE INSTALLATION. COORDINATE SHUNT TRIP OPERATION WITH FIRE ALARM INSTALLER. PROVIDE FUSES PER SHOP DRAWINGS. 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. m1we-jo DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d) O o P- Z z O= Q LU o LL z O0 0 z O N > J > J _� O -0 � O 0 0 I� z m W it C:) U) Z Q LU N U a REVISIO N DATE REASON FOR ISSUE 1 6/18/21 Addendum #1 07/01 /22 AS 1 001.1 10/24/22 AS1005 ONE —LINE DIAGRAM (MDP-1) CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 SHEET NUMBER E4.00 MDP -2 LOAD CALCULATION DEMAND LOAD CALCULATIONS: Dwelling space calculated demand load= Panel Connected Load (VA) # of units factor Total Connected METER DISTRIBUTION PANEL 'MDP' 12A 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 12B 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 13A 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 13B 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 14A 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 14B 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 15A 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 15B 1 BDRM 10 242420 2BDRM 3 0.41 78642 TOTAL 13 Load kVA 132 AMP 365 16A 1 BDRM 8 193936 2BDRM 3 0.42 78642 TOTAL 11 Load kVA 114 AMP 318 16B 1 BDRM 10 242420 2BDRM 2 0.41 52428 TOTAL 12 Load kVA 121 AMP 336 TOTAL 1 BDRM 100 2424200 2BDRM 28 0.23 733992 TOTAL 128 TOTAL DEMAND LOAD AT 120/208V 3-PHASE Load kVA 726 AMP 2016 7 E co M J ii J 11 J 0 COPPER ALUMINUM CONDUCTOR/ RACEWAY TAG Conduit Conductor Conduit Conductor [2000S] * EA. W/4#400KCM I L * EA. W/4#500KCM I L [2500S] * EA. W/4#500KCM I L * EA. W/4#600KCM I L [3000S] * EA. W/4#500KCM I L * EA. W/4#600KCM I L [4000S] * EA. W/4#750KCM I L * EA. W/4#1000KCM I L [100N] 1-1/2" 4#21 1#8G 2" 4#1/0, 1#6G [125N] 2" 4#1, 1#6G 2" 4#1/0, 1#4G [150N] 2" 4#1/0, 1#6G 2" 4#2/0, 1#4G [ 175 N] 2" 4#2/0, 1#6G 2-1/2" 4#3/0, 1#4G [200N] 2-1/2" 4#3/0, 1#6G 2-1/2" 4#4/0, 1#4G [225N] 2-1/2" 4#4/0, 1#4G 3" 4#250KCMIL, 1#2G [250N] 3" 4#250KCM I L, 1#4G 3" 4#350KCM I L, 1#2G [300N] 3" 4#300KCM I L, 1#4G 3-1/2" 4#400KCM I L, 1#2G [350N] 3-1/2" 4#400KCM I L, 1#3G 4" 4#600KCM I L, 1#1G [400N] 3-1/2" 4#500KCMIL, 1#3G (2)2-1/2 If EA. W/4#4/0, 1#1G [500N] 2 2-1 2" EA. W/4#4/0, 1#2G 2 311 EA. W/4#300KCMIL, 1#1/OG [600N] (2)3 11 EA. W/4#300KCMIL, 1#1G (3)3 If EA. W/4#250KCMIL, 1#2/OG [800N] 2 3-1 2" EA. W/4#500KCMIL, 1#1/OG 3 311 EA. W/4#350KCMIL, 1#3/OG [1000N] 3 3-1/2 If EA. W/4#400KCMIL, 1#2/OG (3)4 If EA. W/4#600KCMIL, 1#4/OG [1200N] 4 311 EA. W/4#350KCMIL, 1#3/OG (4)4 It EA. W/4#500KCMIL, 1#250G [1600N] 5 3-1/2 If EA. W/4#400KCMIL, 1#4/OG (5)4 If EA. W/4#600KCMIL, 1#350G [2000N] (6)3-1/2 EA. W/4#400KCM I L, 1#250G (7)4 If EA. W/4#500KCM I L, 1#4000 [2500N] (7)4 11 EA. W/4#500KCM I L, 1#350G (8)4 It EA. W/4#600KCM I L, 1#60OG [20] 3/4" 3#121 1#12G 3/4" 3#10, 1#10G [30] 3/4" 3#101? 1#10G 3/4" 3#8, 1#8G [40] 3/4" 3#8, 1#10G 1" 3#6, 1#8G [50] 1" 3#6, 1#10G 1-1/4" 3#41 1#8G [60] 1" 3#61 1#10G 1-1/4" 3#4, 1#8G [70] 1-1/4" 3#41 1#8G 1-1/4" 3#3, 1#6G [80] 1-1/4" 3#3, 1#8G 1-1/4" 3#2, 1#6G [90] 1-1/4" 3#21 1#8G 1-1/2" 3#11 1#6G [100] 1-1/4" 3#2, 1#8G 1-1/2" 3#1/0, 1#6G [125] 1-1/4" 3#11 1#6G 2" 3#1/0, 1#4G [150] 1-1/2" 3#1/0, 1#6G 2" 3#2/0, 1#4G [175] 2" 3#2/0, 1#6G 2" 3#3/0, 1#4G [200] 2" 3#3/0, 1#6G 2-1/2" 3#4/0, 1#4G * Coordinate with PNM. Final conduit size must be coordinated with PNM prior to purchase and installation. GENERAL NOTES: A. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR TRENCHING, BACKFILLING, COMPACTION, CONDUIT, TRANFORMER PADS OR VAULTS, AND ANY OTHER REQUIREMENTS TO COMPLETE THE UNDERGROUND SERVICE PER SNOHOMISH COUNTY PUD SERVICE REQUIREMENTS MANUAL, KEYED NOTES: 1. 4 INCH HIGH CONCRETE HOUSEKEEPING PAD UNDER SWITCHBOARD, COORDINATE WITH GENERAL CONTRACTOR. 2. CURRENT TRANSFORMER/TERMINAL CABINET PER THE MOST RECENT EDITION OF SNOHOMISH COUNTY PUD SERVICE REQUIREMENTS. 3. CONFIRM UTILITY TRANSFORMER IMPEDANCE. UTILITY TO PROVIDE AVAILABLE FAULT CURRENT. 4. ALL PRIMARY AND SECONDARY CONDUIT, TRENCHING AND BACKEILL, INCLUDING PULL VAULTS, AND CONDUCTORS ARE UNDER THIS CONTRACT, TO INCLUDE TERMINAL LUGS FOR UTILITY CONNECTION, VERIFY REQUIREMENTS WITH SNOHOMISH COUNTY PUD. TRENCHING AND BACKEILL BY GENERAL CONTRACTOR. COORDINATE WITH GENERAL CONTRACTOR. 5. SERVING UTILITY - SNOHOMISH COUNTY PUD. COORDINATE ALL REQUIREMENTS. REFER TO INSTALLATION REQUIREMENTS MANUAL LATEST EDITION, 6. UTILITY SERVICE FEEDERS WITHIN BUILDING FOOTPRINT TO BE INSTALLED BELOW SLAB, ENCASED WITH MINIMUM OF 6" CONCRETE ABOVE. VERIFY WITH AHJ. 7. USE SERIES RATED SWITCHES, BREAKERS AND RELATED EQUIPMENT. USE NEXT HIGHER AIC RATING THAN CALCULATED, 8. INSTALL WARNING RIBBON PER NEC. 9. PROVIDE BREAKER WITH ARC ENERGY REDUCTION PER NEC 240.87 FROM SECONDARY CONNECTION CABINET, SCC-1. REFER TO DWG. [2500S] [60ON] [600N] [60ON] [606N] [600i\ [60ON] [60ON] [600N] [60ON] [60ON] PANEL UNIT PANELS UNITS 6th LEVEL [125] 25A TYPICAL OF (11) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 6th LEVEL [125] 25A TYPICAL OF (12) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 5th LEVEL [125] 25A TYPICAL OF (13) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 5th LEVEL TYPICAL OF [125] 125A (13) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 4th LEVEL [125] 125A TYPICAL OF (13) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 4th LEVEL TYPICAL OF [125] 125A (13) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 3rd LEVEL [125] 125A TYPICAL OF TYPICAL S NGLE PHA E (13) PANEL UNIT PANELS UNITS 3rd LEVEL [125] 125A TYPICAL OF (13) TYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 2nd LEVEL TYPICAL OF [125] 125A (13) tYPICAL S NGLE PHA E PANEL UNIT PANELS UNITS 2nd LEVEL TYPICAL OF [125] 125A (13) TYPICAL S NGLE PHA E 5— O - SNOHOMISH COUNTY 1 PUD INSTALLATION O O MANUAL FOR REQUIRED M 2500A MAIN BRKR CONDITIONS. 600A 3P 600A 3P 1 1 1 1 ❑� NEUT. BUS �I — FULL BUS 600A 3P 600A 3P 600A 3P 600A 3P 600A 3P 600A 3P 2400 AMP RATED BUS GROUND PER NEC 250. DETAIL ON SHEET 600A 3P 600A 3P SPACE 3P MAIN DISTRIBUTION PANEL #2 (MDP-2) 2500A, 208Y/120 VOLT, 3 PHASE, 4 WIRE, 100,000 AIC NEVA 1 RATED PANEL O MDP-2 ONE -LINE POWER DISTRIBUTION DIAGRAM SCALE: N.T.S. p,N - G ASN/ G cn Z 4�7 S/DNAL EN 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N 0 00 d) O o P- Z Z O = � a 0 W C LL Z O0 Z O > J > J _� O -0 1 O 0 0 1� Z m W p Z o U � Q LU N U a REVISIO N DATE REASON FOR ISSUE ONE —LINE DIAGRAM (MDP-2) CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 I KEYED NOTES: 1. MOUNT WEATHERPROOF TOGGLE SWITCH FOR PIT LIGHTING CIRCUIT NEAR TOP OF PIT LADDER. 2. PROVIDE SURFACE MOUNTED LED STRIPLIGHT, FOUR FOOT COLD ROLLED STEEL CHANNEL. WHITE FINISH, OREGUARD, LAMPS GUARDED WITH CLEAR PLASTIC SLEEVES. AVOID LOCATING FIXTURES DIRECTLY BEHIND BEAMS OR STRUCTURE THAT WOULD BLOCK LIGHT. 3. MOUNT GFCI OUTLET FOR ELEVATOR PIT SUMP PUMP ON AREA OF PIT WALL CLOSEST TO SUMP HOLE, PROVIDE DEDICATED CIRCUIT. 4. MOUNT 135' FIXED TEMPERATURE HEAT DETECTOR WITHIN 24 INCHES OF EACH SPRINKLER HEAD IN THE ELEVATOR MACHINE ROOM AND H D I STWAY. 5. MOUNT SMOKE DETECTOR IN ELEVATOR LOBBY ON CEILING TO WITHIN 21 FEET OF ELEVATOR DOOR. 6. MOUNT SHUNT POWER MODULE WITHIN 24 INCHES OF STRIKE SIDE OF DOOR TO ELEVATOR MACHINE ROOM. 7. PROVIDE DEDICATED CIRCUIT. ROUTE INCOMING CIRCUIT TO LUMINAIRES UPSTREAM OF GFCI RECEPTACLE IN BOTH MACHINE ROOM AND ELEVATOR PIT, PER NEC. 8. PROVIDE FUSIBLE SHUNT TRIP POWER MODULE WITH CONTROL TRANSFORMER, TEST SWITCH, PILOT LIGHT, AUXILIARY CONTACTS AND ALARM CONTACTS. PROVIDE 200 AMP. 3POLE SWITCH FOR 208 VOLT SYSTEMS. BUSSMAN, FERRAZ-SHAWMUT, LITTLEFUSE, OR APPROVED. 9. PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER/DRIVE FOR ELEVATOR PRIMARY RECALL, SEE WIRING SCHEMATIC. 10, PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO SHUNT TRIP CONTROL OF ELEVATOR POWER, SEE WIRING SCHEMATIC, 11. ROOM LIGHTING: SEE FLOOR PLAN FOR TYPE, QUANTITY, AND CIRCUITING. 12, PROVIDE SEPARATE DEDICATED CIRCUITS AND LOCKABLE CIRCUIT BREAKERS FOR ELEVATOR CAR LIGHTS AND HVAC. PROVIDE A SIGN TO DENTTY THE LOCATION OF THE OVERCURRENT PROTECTION DEVICES. INDICATE CAR NUMBER AND TYPE OF LOAD NEXT TO EACH CIRCUIT BREAKER. REFER TO FLOOR PLAN FOR LOCATION AND SPECIFIC NAME OF PANEL. 13, PROVIDE HEAT AND SMOKE DETECTORS AT THE TOP OF EACH ELEVATOR SHAFT. 14. CONNECT TO F.A. SYSTEM INITIATING DEVICE CIRCUIT. 15, COORDINATE WALL MOUNTING SPACE FOR ELECTRICAL EQUIPMENT WITH ELEVATOR SUPPLIER/INSTALLER PRIOR TO ROUGH -IN. 16. PROVIDE DEDICATED PHONE LINE IN 3/4"C TO TELEPHONE TERMINAL BOARD. 17, PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER TO ACTIVATE FIREMAN HAT LIGHT IN ELEVATOR CAB UPON INITIATION OF SMOKE DETECTION. 18, CONNECT TO F.A. SYSTEM FOR MONITORING OF CONTROL POWER, 19. PROVIDE ADDRESSABLE F.A. RELAY AND WIRING TO ELEVATOR CONTROLLER FOR ELEVATOR ALTERNATE RECALL. SEE WIRING SCHEMATIC. ELEVATOR CAR ELEVATOR LOBBY ELEVATOR S� MACHINE ROOM 4 ELEVATOR SHAFT ELEVATOR FEEDER FROM POWER O5 TYP. DISTRIBUTION PANEL CONTROL FUSIBLE WIRING SHUNT TRIP F) ELEVATOR LOBBY POWER MODULE 4 SD 04 TYP. BATTERY ELEVATOR LOWERING CONTROLLER DEVICE /DRIVE ELEVATOR CONTROLLF- /DRIVE V1ELEVATOR LOBBY WIDTH OF EQUIPMENT 6'-0" OR TO- BUILDAG STRUCTURE AB OVE, WHICHEVER IS LOWER 6'-0" FOR COMMON AREAS, 48" MAX. TO CENTERLINE OF HIGHEST OPERABLE PART NOTE: CENTERING PANEL IN WORKING SPACE IS NOT REQUIRED FINISH FLOOR ELEVATION WIRING SCHEMATIC ol HYDRAULIC TYPE ELEVATOR DETAIL SCALE: 12" = 1'-0" DEPTH OF ELECTRICAL EQUIPMENT DEDICATED SPACE PER NEC NOTHING EXCEPT ELECTRICAL CONDUIT ALLOWED ANY PIPING OR OTHER EQUIPMENT ABOVE THE DEDICATED SPACE, OR WORKING SPACE TO HAVE DRIP PAN PROTECTION i CLEAR WORKING SPACE COORDINATE SPACE REQUIREMENTS WITH OTHER NSTALLAPON TO TRADES PRIOR TO COMPLY WITH NEC ROUGH IN. 110.26 LATEST EDITION G PANEL & SWITCHGEAR MINUM CLEARANCE J SCALE: 12" = 1'-0" E co co co > 1J J 11 C J 0 F 6'-6" TO FIRE ALARM SYSTEM I ` IJ O �F41 Fi nnR PFNIF 0 H '\TTACHMENT TO STRUCTURE, ARCHITECTURAL CEILING DETAILS 10 #12 GA. GALVANIIZED WIRES ACK) AT DIAGONAL CORNERS OF ;HTING FIXTURES. --CURE TO'T' BAR, WITH HOLD DOWN CLIPS. CLIPS SHALL BE ABLE TO TRANSFER A LATERAL LOAD OF 100% OF THE FIXTURE WEIGHT. NOTE PROVIDE CLOSE -CELL POLYETHYLENE GASKET BETWEEN HOUSING AND T-BAR FOR LIGHTING FIXTURE. 2 LAY —IN FIXTURE MOUNTING DETAIL SCALE: 12" = 1'-0" PROVIDE #6 CU GROUND TO TELECOMM GROUND BUS FINISH FLOOR[ 1/2"C #6 CU' GROUND WIRE BONDED TO MAI PANEL GROUND BUS TELEPHONE TERMINAL BOARD 'TTB' 4'x8'x3/4" FIRE RETARDANT PLYWOOD PROVIDE 4" X 10" CU GROUND BUS BAR (2)2" CONDUIT WITH PULL CORD SPECIFICATION GRADE QUAD RECEPTACLE 3 TELEPHONE TERMINAL BOARD DETAIL SCALE: 12" = 1'-0" 6" MAX. E= Q � FINISH FLOOR 4 VTAC RECEPTACLE DETAIL SCALE: 12" = 1'-0" FINISH GRADE N WARNING TAPE RUN LENGTH OF TRENCH COMPACTED BEDDING AND EARTH BACKFILL = z - 4" MIN. 4" MIN. ;��7_�IiltiZ�77[eI[i ►ICI_\�Y�I�1:Z�K� ►I�I�l�li[iI� N COMPACTED EARTH BACKFILL RE: ONE -LINE DIAGRAM AND SITE PLAN FOR CONDUITS AND CUNDUCTORS TYPICAL TRENCHING DETAIL V SCALE: 1" = V-0" TO INDICATED PAN- 7 FLOOR PENETATRATION DETAIL SCALE: 12" = 1'-0" T #PT7XC FIRE -RATED TROUGH OR APPROVED EQUAL ELS- ELS- ELS- ELS- ELS-1 ELS-1 ELS-1 ELS-1 ELS-2 ELS-2 ELS-2 ELS-2 1 L- 1 L- 1 L- 1 L- 1 L- 1 L- 1 L- 1L 1 6 L- 6 L- 6 L- 6L-1 6L-1 SPAR SPAR SPAR SPAR SPAR SPAR OVERRIDE LIGHTING CONTROL PANE7'LCPAX!1D 8NTS p,N G ASN/ G cn -C) Z FGIZ� SS/ONAL ENG 04/13/22 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21 AMA01 N O 00 d-) O Z z O= Q 0 W C LL z OLij z O N i m J > J '4 O p W Z o `� LZ � Q o' N U a REVISIO N DATE REASON FOR ISSUE 1 6/18/21 Addendum #1 2 12/23/21 Plan Check Response 4 1/03/22 Addendum #03 ELECTRICAL DETAILS CONSTRUCTION SET DATE PROJECT NUMBER 03/14/2022 184470 n I Cn r-) - 7- 0 Lij LL_ 0 0 N >_ CT CD 0 _j >1 0 L. c- 77 C) < _D GENERAL NOTES 1 THE SLACKJACKTm DEVICE COMPONENTS INCLUDE: A. SJA INNER AND OUTER SLEEVE CYLINDERS B. PRE -COMPRESSED COMPRESSION SPRING C. NUT: ALL NUTS TO CONFORM TO ASTM A563 GRADE "A" FOR 60 ksi AND GRADE "C" FOR 120 ksi TENSILE STRENGTH THREADED RODS. D. SWIVEL WASHER 2. ALL THREADED RODS SHALL CONFORM TO THE FOLLOWING SHOP DRAWING MARKS: l. Rx = ASTM A36 OR A307, fu = 60 ksi. 2. RxM ASTM F1 554 GRADE 55, fu = 75 ksi. 3. RxHS ASTM A449 (fu = 120 ksi UP 1". fu = 105 ksi 1-1/8" THRU 2-1/2") or ASTM A193137 (fu = 125 ksi). NOTES: a. x ROD DIAMETER IN EIGHTS OF AN INCH. R7M = 7/8" ASTM F1554 GRADE 55) b. " M ROD ARE ZINC PLATED FINISH. 3. STANDARD AND HIGH STRENGTH i RODS ARE BLACK STEEL, HS WILL BE MARKED NTH AN ORANGE TAPE. 4. ALL BEARING PLATES ARE FABRICATED FROM ASTM A36 STEEL. 5. ALL STEEL BEARING PLATES SHALL HAVE FULL BEARING CONTACT AREA ON WOOD MEMBERS. 6. COUPLING NUT CONNECTION: CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY THAT AT CONNECTIONS WITH THE SAME SIZE ROD THAT EACH ROD IS THREADED HALF WAY INTO COUPLER FROM EACH SIDE. HIGH STRENGTH I COUPLERS SHALL BE USED WITH HIGH STRENGTH (HS) RODS UNLESS NOTED OTHERWISE. STANDARD STRENGTH COUPLERS ARE ZINC PLATED. HIGH STRENGTH (HS) ARE NOT PLATED. WHERE REDUCING COUPLERS ARE USED, COUPLER SHALL BE FULLY SEATED ON THE LARGER DIAMETER ROD BEFORE ENGAGING THE SMALLER DIAMETER ROD. SIGHT HOLES ARE PROMDED ON STRAIGHT COUPLERS ONLY, SIGHT HOLES ARE NOT REQUIRED ON REDUCING COUPLERS. 7. COLORS REFERENCED ON THIS DRAWING ARE PROVIDED FOR CONVENIENCE TO THE INSTALLER AND FOR INSPECTION PURPOSES. 8. SILICONE OR CAULKING SHALL NOT BE PLACED INTO THE SLACKJACK DEVICE OR ANY DRILLED HOLE FOR RODS AT ANY TIME. CONTRACTOR SHALL USE FIRE RATED ROCKWOOL OR NON -HARDENING FIRESTOP. (PROVIDED BY OTHERS). 9. ANCHOR BOLTS ARE SPECIFIED BY EARTHBOUND TO CONFORM TO THE LOADS REQUIRED ON THE STRUCTURAL PLANS. CONTRACTOR SHALL BE RESPONSABLE TO VERIFY AND COORDINATE SCHEDULED ANCHOR BOLTS WITH THESE ASSEMBLIES. 10. HOLDOWN RUN ELEVATION VIEWS ARE DIAGRAMS AND MAY NOT DEPICT THE CORRECT NUMBER OF COLLECTOR STUDS REQUIRED. REFER TO COLLECTOR STUD PLAN DIAGRAMS FOR REQUIRED AMOUNT OF ADDITIONAL STUDS DEPENDING ON SHEAR WALL FRAMING TYPE. ADDITIONAL COMPRESSION STUDS OR POSTS MAY BE REQUIRED BY THE STRUCTURAL PLANS FOR DEAD AND LIVE LOADS. 11. THIS DRAWING WILL BE REVIEWED BY THE ENGINEER OF RECORD. UPON APPROVAL, U.N.O. THIS DRAWING REPLACES THE HOLDOWN SYSTEM PER THE STRUCTURAL PLANS. 12. ENGINEER OF RECORD SHALL VERIFY COMPLETE LOAD TRANSFER TO FOUNDATION LEVEL INCLUDING ALL CODE REQUIRED LOAD FACTORS. 13. WOOD FLOOR LEVELS SHOWN ARE RELATIVE TO THE CONCRETE FOUNDATION AND MAY NOT REFLECT THOSE SHOWN IN THE PLANS. 14. CONTRACTOR MAY SUBSTITUTE POSTS WITH 2x MEMBERS OR VICE VERSA ONLY IF TOTAL BEARING PLATE AREA ON BOTTOM PLATE IS EQUAL. 15. REFER TO THE COLLECTOR STUD SCHEDULE FOR WOOD STUD AND FLOOR PLATE MATERIALS USED IN LOAD CALCULATION ASSUMPTIONS. THE MATERIALS SHALL MATCH STRUCTURAL DRAWING REQUIREMENTS UNLESS NOTED OTHERWISE. 16. FULL HEIGHT COLLECTOR STUD REQUIREMENTS (NOT AT BRIDGE LEVEL - SEE 17A): A. FULL HEIGHT BUNDLED 2x, 3x COLLECTOR /COM P R ESSI ON STUDS, THE OUTERMOST STUD FROM EACH SIDE OF THE THREADED ROD SHALL RECEIVE EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. EDGE NAILING MAY BE STAGGERED/DISPERSED ON (2) MEMBERS MAX. ANY REMAINING INTERIOR STUDS SHALL RECEIVE FIELD NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. B. FULL HEIGHT 4x COLLECTOR /COM P R ESSI ON AT OUTERMOST POST FROM EACH SIDE OF THE THREADED ROD SHALL RECEIVE ONE (1) ROW OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. ANY REMAINING 2x, 3x, 4x INTERIOR MEMBERS SHALL RECEIVE FIELD NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. C. FULL HEIGHT 6x AND LARGER COLLECTOR /COM P R ESSI ON AT OUTERMOST POST FROM EACH SIDE OF THE THREADED ROD SHALL RECEIVE TWO (2) ROWS OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. ANY REMAINING INTERIOR POSTS CAN BE FIELD NAILED PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. D. WINDOW AND DOOR TRIMMERS MAY BE USED AS HOLDOWN COLLECTOR STUDS IF THE FOLLOWING CONDITIONS ARE MET: - A CONTINUOUS VERTICAL LOAD PATH SHALL EXIST FROM WALL TOP PLTS. TO WALL BOTTOM PLTS. - ALL WOOD MEMBERS IN THE CONTINUOUS VERTICAL LOAD PATH SHALL BE NAILED ACCORDING TO THE EARTHBOUND SYSTEM REQUIREMENTS. - THE SHEAR PANEL MUST EXTEND TO INCLUDE THE TRIMMERS USED. E. COMPRESSION STUDS/POSTS SHALL BE INSTALLED SYMMETRICALLY ABOUT ROD. WHERE QUANTITY OF STUDS IS GREATER THAN THE SPACE BETWEEN ROD OR BEARING PLATE AND THE END OF SHEAR WALL THE ADDITIONAL REQUIRED STUDS SHALL BE ADDED TO THE OPPOSITE SIDE OF ROD (ASYMMETRICALLY). F. STITCH NAILING OF BUNDLED OR BUILT UP STUD PACKS SHALL CONFORM TO IBC TABLE 2304.10.1. 17. COMPRESSION BRIDGE REQUIREMENTS: A. ALL FULL HEIGHT 2x AND 3x MEMBERS ON EITHER END OF THE BRIDGE SHALL RECEIVE EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. B. ALL FULL HEIGHT 4x COLLECTOR /COM P R ESSI ON POSTS ON EITHER SIDE OF THE BRIDGE SHALL RECEIVE ONE (1) ROW OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. C. ALL FULL HEIGHT 6x AND LARGER COLLECTOR /COM P R ESSI ON POSTS ON EITHER SIDE OF THE BRIDGE SHALL RECEIVE TWO (2) ROWS OF EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS. D. ALL BRIDGE TRIMMERS SHALL BE 2x MEMBERS ONLY (U.N.O.) AND SHALL BE INSTALLED SYMMETRICALLY AS SHOWN (U.N.O.). E. ALL BRIDGE TRIMMERS SHALL RECEIVE EDGE NAILING PER THE SHEAR WALL SCHEDULE OF THE STRUCTURAL PLANS (U.N.O.). F. THE BRIDGE TRIMMERS ADJACENT TO THE FULL HEIGHT STUDS (ONE EACH SIDE) SHALL RECEIVE FACE (STITCH) NAILING TWO (2) ROWS AT 4" O.C. TRIMMERS IN ADDITION TO ONE EACH SIDE SHALL BE STITCH NAILED AT 12" O.C. AS REQUIRED BY IBC TABLE 2304.10.1. FACE NAILS MAY BE NAILED FROM THE OPPOSITE DIRECTION THAN THAT SHOWN IN THE DETAIL. G. FACE NAILS SHALL BE 10d MINIMUM. USE 16d NAILS MINIMUM WHEN NAILING THROUGH 3x STUDS INTO 2x BRIDGE TRIMMERS. H. IF MULTIPLE BRIDGE TRIMMERS ON EACH SIDE ARE REQUIRED, DO NOT INSTALL THE TRIMMERS IN ADDITION TO ONE EACH SIDE UNTIL THE FACE NAILING HAS BEEN INSPECTED AND APPROVED. 1. BRIDGE BLOCK SHALL BE 4x6 DF IN 4x WALLS, 6x6 DF IN 6x WALLS (U.N.O.). BRIDGE BLOCK SHALL ALWAYS BE 5-1/2" TALL MINIMUM. J. BRIDGE BLOCK SHALL BE DOUGLAS FIR CONSTRUCTION GRADE WITH MINIMUM 800 PSI ALLOWABLE BENDING STRESS. TIMBERSTRAND LSL BEAM MATERIAL OF EQUAL OR GREATER DIMENSION IS AN ACCEPTABLE ALTERNATE (U.N.O.). K. BRIDGE HEIGHTS SHOWN ARE THE MINIMUM HEIGHT FROM SUBFLOOR TO BOTTOM OF BRIDGE MEMBER. ONLY COMMON NAILS SHALL BE USED. 18. DRILLED OR BORED HOLES: DRILLED HOLES THROUGH VERTICAL COMPRESSION MEMBERS SHALL NOT EXCEED 25% OF THE STUD OR POST WIDTH, FOR EXAMPLE: 7/8" DIA. HOLE IS MAXIMUM ALLOWED IN 3 1/2" WIDE STUD OR POST UNLESS APPROVED BY EOR. THE BORED HOLE SHALL BE AT LEAST 5/8" AWAY FROM EDGE OF STUD. 19. CUTTING AND NOTCHING: WOOD VERTICAL COMPRESSION MEMBERS ARE PERMITTED TO BE CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25% OF IT'S WIDTH PER 2308.9.10 PER IBC 2015. 20. STUD/POST/TRIMMER NOTCHING AT CONFLICTING BEARING PLATES INTERFERENCE. A. THE MEMBER SHALL BE NOTCHED TO THE EXACT THICKNESS AND AREA OF THE STEEL PLATE TO MAINTAIN THE FULL BEARING AREA OF THE NOTCHED COMPRESSION MEMBER. B. IF THE REQUIREMENTS OF ITEM "A" ABOVE ARE NOT MET, THEN ADDITIONAL COMPRESSION MEMBERS SHALL BE ADDED TO ACHIEVE THE REQUIRED TOTAL BEARING AREA. ADDITIONAL COMPRESSION MEMBERS SHALL RECEIVE SHEAR PANEL NAILING PER THE REQUIREMENTS OF THE EARTHBOUND SHOP DRAWINGS. C. STEEL SHIMS OR FULL WIDTH PLATE MAY BE USED IN LIEU OF NOTCHING. 21. MINIMUM REQUIREMENTS FOR BLOCKING IN THE JOIST SPACE AT HOLDOWN LOCATIONS ARE: A. BLOCKING SHALL SPAN THE FULL WIDTH OF THE SHEAR WALL TOP PLATE OF THE FLOOR LEVEL BELOW THE JOIST SPACE. B. BLOCKING SHALL EQUAL THE OUTERMOST DIMENSIONS OF THE "FOOTPRINT" OF THE TOTAL HOLDOWN WOOD COMPRESSION MEMBERS OF THE FLOOR LEVELS BELOW AND ABOVE THE JOIST SPACE. C. THE SPACE BETWEEN BLOCKING WHERE THE ROD IS LOCATED SHALL NOT EXCEED 3". D. COMPRESSION CAPACITIES OF BLOCKING MATERIALS SHALL BE EQUAL TO OR GREATER THAN THE RELATED JOISTS. THE VERTICAL DIMENSIONS SHALL BE EQUAL. SEE NOTE "E" FOR EXCEPTION. E. VERTICAL GRAIN BLOCKING SHALL BE TRIMMED TO ACCOUNT FOR POSSIBLE SHRINKAGE OF THE JOISTS. CONTACT JOIST MANUFACTURER FOR SHRINKAGE INFORMATION. F. FLOOR JOISTS SHALL NOT BE REMOVED TO ALLOW FOR THE INSTALLATION OF BLOCKING. BLOCKING IS IN ADDITION TO THE EXISTING JOISTS. G. WEB STIFFENERS SHALL BE ADDED TO ENGINEERED LUMBER "I" JOISTS AND "Ill JOIST MATERIAL USED AS BLOCKING. SEE NOTE "B" ABOVE. JOB SPECIFIC NOTE: PRO\ADE NAILING PER 6/S7.04 AT INTERSECTIING SHEAR WALLS WITH HOLDOWNS. NO EXCEPTIONS TAKEN REVISE AND RESUBMIT El MAKE CORRECTIONS NOTED REVIEW NOT REQUIRED This review is only for general conformance with the design concept and the information given in the Construction Documents. Corrections or comments made on the submittal during this review do not relieve the contractor from compliance with the requirements ofthe plans and specifications. Re0ew ofa specific item shall not include review of an assembly of which the item is a component . The Contractor is responsible for dimensions to be coni and correlated at the jobsite; information that pertains solely to the fabrica ion processes or to the means, methods, techniques, sequences and procedures of construc ion; coordination of the Work with that of all other trades and perf.rmingtall Work in a safe and satisfactory manner. i Consulting Engineers Date 07/22/2022 1q)ff By andi REVIEWED August 27, 2022 Reviewed by: DBeck BECK & ASSOCIATES, PLLC ABBREVIATIONS AB ANCHOR BOLT PER ROD COMPONENT SCHEDULE BLKG BLOCKING C COUPLER FND FOUNDATION G HOT DIPPED GALVANIZED ROD OR GALV. TAPPED COMPONENT GG COUPLER GALV. TAPPED ON BOTH ENDS GS COUPLER GALV. TAPPED ON SMALL END ONLY CB CORROSION BARRIER HS HIGH STRENGTH SJA 4XY SLACKJACKTM COMPONENT (X) =: SLACKJACK DEVICE SERIES TRAVEL 1=1 INCH (RED), 2=2 INCHES (GREEN) (Y) = ROD SIZE JST JOIST MIN. MINIMUM 0. C. ON CENTER P PLATE PG PERPENDICULAR TO GRAIN R ROD U. N. 0. UNLESS NOTED OTHERWISE SHOP DRAWING DISCLAIMER THESE SHOP DRAWINGS ILLUSTRATE THE DETAILS OF THE EARTHBOUND SEISMIC HOLDOWN SYSTEM. THEY WERE PREPARED IN CONFORMANCE WITH THE STRUCTURAL DESIGN PROVIDED TO EARTHBOUND CORPORATION ('YEB CORP.yy) BY THE PROJECT OWNER OR ITS REPRESENTATIVE. EB CORP. TOOK NO PART IN THE PREPARATION OR REVIEW OF SAID STRUCTURAL DESIGN AND EB CORP DISCLAIMS ANY LIABILITY FOR IT. THE STAMP OR SEAL OF AN EB CORPORATION EMPLOYEE OR AGENT ON THESE SHOP DRAWINGS PERTAIN ONLY TO THE TRANSFER OF THE FORCES REQUIRED BY THE ENGINEER OF RECORD ON THE STRUCTURAL DRAWINGS AND NOT TO THE REVIEW AND ADEQUACY OF THE STRUCTURAL DESIGN. NO WARRANTY, EXPRESSED OR IMPLIED, AS TO THE ADEQUACY OF THE STRUCTURAL DESIGN IS MADE BY ANY SUCH STAMP OR SEAL. COLLECTOR STUD DIAGRAM KEY WALL TYPE (TYP) V) ui 0 1 < [---J C/') C_ Lj_ LL_ OQ WOOD SPECIES-/4K FRAMING LVL AND HEIGHT -APPROX. ROD LOCATION (TYP) -ANCHOR BOLT LAYOUT DIMENSION (TYP) STUD OR POST (TYP) _ . SHEAR WALL '*�_STUD/POST (QTY) & DESCRIPTION (TYP) END MEMBERS (TYP) _�'A COLLECTOR STUDS REQUIRED '4x WALLS: C,-j 1 -0 12" i - 1XI + 1>1 _j 4x6 4x8 6x WALLS: /__ > _j 12" 1# _" + M Q�ij 5 2x s TOTAL 1. * (ASTERISK) INDICATES 1/2 HEIGHT TRIMMER (UNLESS NOTED OTHERWISE) FOR COMPRESSION BRIDGE. 2. COLLECTOR STUDS SHOWN ARE THE MINIMUM REQUIREMENT TO EQUAL THE UPLIFT TENSION FORCES CALLED OUT BY THE STRUCTURAL DWGS. ADDITIONAL COMPRESSION STUDS OR POSTS MAY BE REQUIRED BY STRUCTURAL ENGINEER OF RECORD. APPLIES TO ALL HOLDOWN RUNS. COMPONENT SELECTION SCHEDULES EARTHBOUND THREADED ROD CAPACITIES (IBC 2015) ROD SIZE ROD SZE (INCHES) ALLOWA13LE TENSON LOAD IBC 2015 ROD RBAAPJ(S SLACKJACK SIZE R4 1/2" DIA. 4,470 LBS ASTM A 307 (UNC) MJ100, MJ200 R5 5/8" DIA. 7,120 LBS ASTM A 307 (UNC) SJA 215, 225, 415, 425 R6 3/4" DIA. 10,540 LBS ASTM A 307 (UNC) SJA 216, 226, 416, 426, HJA 716, 726 R7 7/8" DIA. 14,540 LBS ASTM A 307 (UNC) SJA 217, 227, 417, 427, HJA 717, 727 IRS 1" DIA. 19,080 LBS ASTM A 307 (UNC) SJA 218, 228, 418, 428, HJA 718, 728 R9 1 1/8" DIA. 24,040 LBS ASTM A 307 (UNC) SJA 219, 229, 419, 429, HJA 719, 729 RIO 1 1/4" DIA. 30,530 LBS ASTM A 307 (UNC) SJA 4110, 4210, HJA 7110, 7210, HJS 4110, 4210, 7110, 7210 R12 1 1/2" DIA. 44,270 LBS ASTM A 307 (UNC) SJST 4112, 4212, HJA 7112, 7212, HJS 4112, 4212, 7112, 7212 R14 1 3/4" DIA. 59,830 LBS ASTM A 307 (UNC) ----- RSM 3/4" DIA. 13,170 LBS ASTM Fl 554 CR55 (UNC) SJA 216, 226t 416, 426, HJA 716, 726 R7M 7/8" DIA. 18,180 LBS ASTM Fl 554 CR55 (UNC) SJA 217, 227, 417, 427, HJA 717, 727 Pam 1" DIA. 23,850 LBS ASTM Fl 554 GR55 (UNC) SJA 218, 228, 418, 428, HJA 718, 728 R9M 1 1/8" DIA. 30,050 LBS ASTM Fl 554 GR55 (UNC) SJA 219, 229, 419, 429, HJA 719, 729 RIOM 1 1/4" DIA. 38,160 LBS ASTM Fl 554 GR55 (UNC) SJA 4110, 4210, HJA 7110, 7210, HJS 4110, 4210, 7110, 7210 R12M 1 1/2" DIA. 55,330 LBS ASTM F1554 GR55 (UNC) SJST 4112, 4212, HJA 7112, 7212, HJS 4112, 4212, 7112, 7212 R1 4M 1 3/4" DIA. 74,790 LBS ASTM Fl 554 GR55 (UNC) ----- RII 3/4" DIA. 21,950 LBS ASTM Al 93 B7 (UNC) SJA 216, 226, 416, 426, HJA 716, 726 R7HS 7/8" DIA. 30,300 LBS ASTM Al 93 B7 (UNC) SJA 217, 227, 417, 427, HJA 717, 727 R8HS 1" DIA. 39,750 LBS ASTM Al 93 B7 (UNC) SJA 218, 228, 418, 428, HJA 718, 728 R9HS 1 1/8" DIA. 50,090 LBS ASTM Al 93 B7 (UNC) SJA 219, 229, 419, 429, HJA 719, 729 R1OHS 1 1/4" DIA. 63,600 LBS ASTM Al 93 B7 (UNC) SJA 4110, 4210, HJA 7110, 7210, HJS 4110, 4210, 7110, 7210 R12HS 1 1/2" DIA. 92,220 LBS ASTM Al 93 B7 (UNC) SJST 4112, 4212, HJA 7112, 7212, HJS 4112, 4212, 7112, 7212 R14HS 1 3/4" DIA. 124,650 LBS ASTM Al 93 B7 (UNC) ----- COLLECTOR STUD CAPACITY SCHEDULES COLLECTOR STUD CAPACITIES FOR DOUG FIR STUDS ON DOUG FIR PLATES TOTAL 10'-2* CAPACITY 4-6*/6'-0* CAPACITY STUDS REQUIRED 2x4 SMDS 2x6 STUDS 4X4 POSTS 4x6 POSTS 4x8 POSTS 6X6 POSTS BRIDGE TRIMMERS ONLY QTY. NO. OF BRIDGE TRIMMERS 2x4ls 2x6s SINGLE CAPACITY- 2,152# 3,506# 5,020# 7,873# 10,355# 12,856# 2,2 31 # 3,506# 2 4,303# 7,013# 10,040# 15,746# 20,711 # 25,713# 2* 4,463# 7,013# 3 6,455# 10,519# 15,061 # 23,620# 31,066# 38,569# 4 8,606# 14,025# 20,081 # 31,493# 41,422# 51,425# 4* 8,925# 14,025# 5 10,758# 17,531 # 25,101 # 39,366# 51,777# 64,281 # 6 12,909# 21,038# 30,121 # 47,239# 62,133# 77,138# 6* 13,388# 21,038# 7 15,061 # 24,544# 35,141 # 55,113# 72,488# 89,994# 8 17,212# 28,050# 40,162# 62,986# 82,844# 102,850# 8* 17,850# 28,050# 9 19,364# 31,556# 45,182# 70,859# 93,199# 115,706# 10 21,515# 35,063# 50,202# 78,732# 103,555# 128,563# NOTES: 1) STUDS SHOWN ARE THE MINIMUM COMPRESSION MEMBERS REQUIRED FOR THE EARTHBOUND SYSTEM. 2) DOUG FIR CALCULATION NOTES: (BASED ON 2015 NDS) 2x4s, 2x6s, 3xs, 4x4s AND LARGER (No. 2 GRADE): F'c PARALLEL = 1350 PSI 6x6s AND LARGER (No. 1 GRADE) F'c PARALLEL = 1000 PSI 3) DENOTES NO. OF BRIDGE TRIMMERS UNDER COMPRESSION BRIDGE. 4) DENOTES THAT FINAL POST HEIGHT SUBTRACTS 4 1/2" FOR 2x TOP PLATES AND 2xBOTTOM PLATE. EARTHBOUND BEARING PLATE CAPACITIES (DF) SJA ROD SIZE CODES PLATE SZE DIFFEUNT11AL LOAD COLOR CODE PLATE DIMENSIONS (INCHES) PART NO. ROD DIAMETER ROD SZE WAMER COLOR VADTH UNM THICK Pa 6,650 LBS GREEN 3" 3.5" 1/4" MJ100 or MJ200 1/2" R4 PURPLE Pa 8,470 LBS BLACK 3-1/4" 4.25" 1/4" SJA 2x5 or 4x5 5/8" R5 BLACK P10 10,320 LBS BLUE 3-1/4" 5" 3/8" SJA 2x6 or 4x6, HJA 7x6 3/4" R6 or R6HS GRAY P12 12,230 LBS GRAY 3-1/4" 6" 5/8" SJA 20 or 40, HJA 70 7/8" R7 or R7HS BLUE P14 13,660 LBS RED 3-1/4' 7" 3/4" SJA 2x8 or 4x8, HJA 7x8 ill R8 or R8HS YELLOW Pla 18,840 LBS YELLOW 3-1/2" 91, 1. SJA 2x9 or 4xg, HJA 7x9 1 1/8" R9 or R9HS WHITE P20 21,020 LBS BROWN 3-1/2" loll 1. SJA 4xl 0, HJA 7x10, HJS 410, 7xl 0 1 1/4" R10 or RlOHS GREEN P22 23,210 LBS WHITE 3-1/2" ill' 1 1/4" SJST 4xl 2, HJA 7xl 2, HJS 4xl 2, 7xl 2 1 1 1/2" 1 R12 or Rl 2HS RED P24 24,310 LBS GOLD 3-1/2" 11.5" 1 1/4" 11 x"= SLACKJACK TRAVEL IN "INCHES" P26 26,490 LBS ORANGE 3-1/2" 12.5" 1 1/2" NOl 1. TENSION LOAD WAS CALCULATED FROM THE FOLLOWING EQUATION: A. ASTM A 307 Threaded Rod CqxmMn am ru - 60.000 p4 UNC Un plitil M Rode cm b=ed an AgN n554 GR.FA ru - 75 kd. HS Rode am ' - ' an AM A193 ff7, ru - 125 kil B. The IBC 20115 odumn to adell In minan Ill- oe to SwItIon 19M and MIX 7-10. 2. PLATE STEEL SHALL BE ASTM A36: Flu = 60,000 PSI. 3. SUBSTITUTIONS OF DESIGNATED BEARING PLATE SHALL NOT BE PERMITTED, OBTAIN WRITTEN APPROVAL FROM THE ENGINEER. 4. ALL BEARING PLATE CAPACITIIES ARE BASED ON 1-1/16" HOLE, UNLESS NOTED OTHERWISE. 5. SLACKJACK SELECTION NOTES: THE SIZES SHOWN ABOVE ARE FOR BOTH ONE AND TWO INCH TRAVEL ("SJA 4xy") (x = TRAVEL HEIGHT IN INCHES = ROD SIZE) TWO INCH TRAVEL SLACKJACKS , y . ARE REQUIRED ON FOURTH WOOD FRAME LEVELS AND HIGHER. 6. THIS TABLE IS FOR REFERENCE OF FULL PRODUCT LINE, SOME ROD AND PLATE SIZES MAY NOT BE IN USE. THE ENGINEER OF RECORD SHALL REVIEW AND APPROVE CAPACITIES. 7. ALL A36/A307 THREADED ROD WILL BE 10' IN LENGTH AND ALL A193 B7 THREADED ROD WILL BE 12' IN LENGTH (U.N.O.) X = DETAIL NUMBER Y = ELEVATION SHEET Z = DETAIL DRAWN ON EARTHBOUND DETAIL BUBBLE LEGEND TYPICAL TI SLACKJACK COLOR KEY 0�/-PART NO. SJA 418 I RED IYELLOW "CAPTURE RING--/4' WASHER COLOR COLOR SECONDARY COLOR APPLIES TO HJS MODEL/SERIES OUTER CYLINDER ONLY. DEVICE CAN BE ACTIVATED AS SOON AS IT IS INSTALLED AND HEX NUT TIGHTENED IN PLACE. CAPTURE RING (SEE COLOR CODE) PULL CLIP MINIJACK PULL CLIP SLACKJACK IAPMO ER-0429 & LABC LISTED CAPACITIES COLOR CODE AND MODEL/SERIES TO PART NUMBER CROSS REFERENCE iTOP NUT SWIVEL WASHER (SEE COLOR CODE) CAPTURE RING (SEE COLOR CODE) BEARING PLATE IAPMO ER-0429 /LABC MODEL/SERIES SLACKJACK PART NO. ON DWGS THREADED ROD DIAMETER COMPRESSION CAPACITY TRAVEL COMPENSATION AMOUNT CAPTURE RING COLOR SWI W A S�H �EER COLOR IAPM /0 ER-0429 LABC MODEL/SERIES SLACKJACK PART NO. ON DWGS THREADED ROD DIAMETER COMPRESSION CAPACITY TRAVEL COMPENSATION AMOUNT CAPTURE RING COLOR SWIVEL I WASHER� COLOR M 100 Miloo 1/2" 5,000 LBS 1-INCH RED N/A M 200 MJ 200 1/2" 4,900 LBS 2-INCH ORANGE NIA A 210 SJA 215 5/8" 7,360 LBS 1-INCH BLUE BLACK A 220 SJA 225 5/8" 7,730 LBS 2-INCH YELLOW BLACK A 210 SJA 216 3/4" 7,360 LBS 1-INCH BLUE GRAY A 220 SJA 226 3/4" 7,730 LBS 2-INCH YELLOW GRAY A 210 SJA 217 7/8" 7,360 LBS 1-INCH BLUE BLUE A 220 SJA 227 7/8" 7,730 LBS 2-INCH YELLOW BLUE A 210 SJA 218 ill 7,360 LBS 1-INCH BLUE YELLOW A 220 SJA 228 ill 7,730 LBS 2-INCH YELLOW YELLOW A 210 SJA 219 1 1/8" 7,360 LBS 1-INCH BLUE WHITE A 220 SJA 229 1 1/8" 7,730 LBS 2-INCH YELLOW WHITE A 410 SJA 415 5/8" 14,000 LBS 1-INCH RED BLACK A 410 SJA 416 3/4" 14,000 LBS 1-INCH RED GRAY A 410 SJA 417 7/8" 14,000 LBS 1-INCH RED BLUE A 410 SJA 418 ill 14,000 LBS 1-INCH RED YELLOW A 410 SJA 419 1 1/8" 14,000 LBS 1-INCH RED WHITE A 410 SJA 4110 1 1/4" 14,000 LBS 1-INCH RED GREEN T 410 SJT 415 5/8" 9,000 LBS 1-INCH ORANGE BLACK T 410 SJT 416 3/4" 9,000 LBS 1-INCH ORANGE GRAY T 410 SJT 417 7/8" 9,000 LBS 1-INCH ORANGE BLUE T 410 SJT 418 ill 9,000 LBS 1-INCH ORANGE YELLOW T 410 SJIT 419 1 1/8" 9,000 LBS 1-INCH ORANGE WHITE T 410 SJT 4110 1 1/4" 9,000 LBS 1-INCH ORANGE GREEN HA 710 HJA 717 7/8" 15,650 LBS 1-INCH PURPLE BLUE HA 710 HJA 718 ill 15,650 LBS 1-INCH PURPLE - YELLOW HA 710 HIJA 719 1 1/8" 15,650 LBS 1-INCH PURPLE WHITE HA 710 HJA 7110 1 1/4" 15,650 LBS 1-INCH PURPLE GREEN HA 710 HJA 7112 1 1/2" 15,650 LBS 1-INCH PURPLE - RED HA 720 HJA 727 7/8" 15,590 LBS 2-INCH GRAY BLUE HA 720 HJA 728 ill 15,590 LBS 2-INCH GRAY YELLOW HA 720 HJA 729 1 1/8" 15,590 LBS 2-INCH GRAY WHITE HA 720 HJA 7210 1 1/4" 15,590 LBS 2-INCH GRAY GREEN HA 720 HJA 7212 1 1/2" 15,590 LBS 2-INCH GRAY RED HS 410 HJS 419 1 1/8" 22,000 LBS 1-INCH BLACK** WHITE HS 410 HIJS 4110 1 1/4" 22,000 LBS 1-INCH BLACK** GREEN HS 410 HIJS 4112 1 1/2" 22,000 LBS 1-INCH BLACK** RED *SJST4210 1 1/4" 22,000 LBS 1 1/2-INCH BLACK GREEN *SJST41 10 1 1/4" 22,000 LBS 1-INCH RED GREEN *SJST4112 1 1/2" 22,000 LBS 1-INCH RED RED SLACKJACK TAKE UP DEVICE WITH AR = 0.003 IN. NOT SHOWN IN ER-0429. OUTSIDE CYLINDER COLOR AS FOLLOW: HJS41=BLUE, HJS42=YELLOW, HJS71=GREEN, HJS72=ORANGE A 420 SJA 425 5/8" 14,000 LBS 2-INCH GREEN BLACK A 420 SJA 426 3/4" 14,000 LBS 2-INCH GREEN GRAY A 420 SJA 427 7/8" 14,000 LBS 2-INCH GREEN BLUE A 420 SJA 428 ill 14,000 LBS 2-INCH GREEN YELLOW A 420 SJA 429 1 1/8" 14,000 LBS 2-INCH GREEN WHITE A 420 SJA 4210 1 1/4" 1 14,000 LBS 2-INCH GREEN GREEN A 610 SJA 616 3/4" 20,340 LBS 1-INCH TAN GRAY A 610 SJA 617 7/8" 20,340 LBS 1-INCH TAN BLUE A 610 SJA 618 ill 20,340 LBS 1-INCH TAN YELLOW A 610 SJA 619 1 1/8" 20,340 LBS 1-INCH TAN WHITE I A 610 I SJA 6110 1 1/4" 20,340 LBS 1-INCH I TAN 1 GREEN A 620 SJA 627 7/8" 20,100 LBS 2-INCH WHITE BLUE A 620 SJA 628 1. 20,100 LBS 2-INCH WHITE YELLOW A 620 SJA 629 1 1/8" 20,100 LBS 2-INCH WHITE WHITE A 620 SJA 6210 1 1/4" 1 20,100 LBS 2-INCH WHITE GREEN HS 420 HJS 429 1 1/8" 22,000 LBS 2-INCH BLACK" WHITE HS 420 HJS 4210 1 1/4" 22,000 LBS 2-INCH BLACK" GREEN HS 420 HJS 4212 1 1/2" 22,000 LBS 2-INCH BLACK" RED HS 710 HJS 719 1 1/8" 39,190 LBS 1-INCH BLACK" WHITE HS 710 HJS 7110 1 1/4" 39,190 LBS 1-INCH BLACK" GREEN HS 710 HJS 7112 1 1/2" 39,190 LBS 1-INCH BLACK" RED HS 720 HJS 729 1 1/8" 37,770 LBS 2-INCH BLACK" WHITE HS 720 HJS 7210 1 1/4" 37,770 LBS 2-INCH BLACK" GREEN HS 720 HJS 7212 1 1/2" 37,770 LBS 2-INCH BLACK" RED SLACKJACK COLOR CODE TABLE TRAVEL HEIGHT AND ROD SIZE COORDINATION Si 428 -7-- ROD DIA IN EIGHTH INCH MODEL: SLACKJACK-- T MODEL TYPE: TRAVEL IN INCHES A=ALUM, S=STEEL SERIES TYPE (# RINGS) PANEL NAILING TIM SLACKJACK i-NUT (TYP) DEVICE-\ REFER TO EACH RUN TYPE FOR TOTAL NUMBER OF TRIMMERS REQUIRED. _j FULL HEIGHT STUD TYP. �!�l L�A LVAI - 11L R 0 D P-PLATE--L REQUIRED BRIDGE SHEAR WALL BOTTOM PLATE TRIMMER (TYP) OR BRIDGE. FACE LADDITIONAL TYP. P- PLATE ORIENTATION NAILING TYP. TRIMMER(S) TYP. & SAMPLE BRIDGE TRIMMER NAILING DETAIL SCALE: NONE ROD HOLE SCHEDULE THROUGH TOP/BOTTOM PLATES AND BRIDGES ROD SIZE MIN HOLE SIZE MAX HOLE SIZE R4 1 /2"0 1 0 1-1/8"o R5 5/8"o 1"0 1-1 /8"0 R6 3/4"0 1"0 1-1 /8"0 R7 7/8"0 1-1 /8"0 1-1 /4"0 R8 V)o 1-1 /4"0 1-3/8"0 R9 1-1/8"o 1-3/8"0 * 1-1/2"0 R10 1-1/4"0 1-1/2"0 * 1-5/8"0 HOLE SIZES INTENDED FOR 6 WALL TYPES ONLY. ENGINEER OF RECORD SHALL APPROVE THE USE OF THESE HOLE SIZES FOR 4" WALL TYPES. ALL SHEAR PANEL NAIL SPACING IS PER THE SHEAR WALL SCHEDULE EDGE NAIL FULL HEIGHT MEMBER ATEACH END OF BRIDGE BLOCK. IEDGE NAIL ALL BRIDGE TRIMMERS. BRIDGE TRIMMER FACE (STITCH) NAILING PER SHOP DRAWINGS. REQUIRED ON TWO (2) TRIMMERS ONLY. BRIDGE LEVEL FULL HEIGHT COMPRESSION MEMBER LEVELS 0 0 0 0 0 0 0 0 0 0 _.lq 0 0 0 0 0 0 END OF SHEAR WALL (1) ROW OF 3" LENGTH x 0.131" STITCH ,--,-DIAMETER NAILING AT 12" O.C. REQUIRED BY IBC TABLE 2304.10.1 EDGE NAILING REQ'D 6`11 AT THE OUTERMOST 0 1 STUD/POST ON 0 �_ BOTH SIDES OF ROD ANY ADDITONAL STUDS/POSTS CAN BE FIELD NAILED. NAILS MAY BE DISPERSED AND STAGGERED ON MULTIPLE MEMBERS. NOTE: SEE SHOP DRAWING GENERAL NOTES FOR NAILING REQUIREMENTS WHEN POSTS ARE USED. NAILING SAMPLE BLD2021-0088 DEF SUB3- HOLD DOWNS RECEIVED Aug 23 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT C14 0 C*4 '11� 0 0 Ld I-_ < z 0 0 w F_- Z a- < - j 1 Cn _j Ll < C) 0 W Ld 13- 0 Ld 0 5; LIJ 0 C14 Lij 0 < 47 C� 0 <I 0 U� > Ld 0:� LLJ Lij 0 Ld 0 > < Z < < 0 3: 0 < Cn Lli Or-, LIJ CL C) < P M -6i W_ k 1-0421 Nh*A > , L r ` ............ e �e %0&�/ONAL 0 C4 0 co z 0 z a 0 LU Um > 0 >m (9 0 cm mi ri'll 0 0 0 N z Ll D 0 Q--, CL E 0-) CN 0 Q0 CN (0 r- (� U-) (D 0 CID E M 00 0 J:� (D (D 3: C:) (.0 3: 00 1`0 3: X 0 4- 0 < ck� 0 Lij C/) 0 Q) 0 Q) 00 L.. 0-) 4- V) < =) Q) 3;: 0 CID 0 --- CO O:� ro < 0 Z C4 EB CORP JOB NO: 20491 SHEET TITLE: EARTHBOUND SEISMIC HOLDOWN SYSTEM INSTALLATION DRAWINGS IAPIVIO FR-0429 DATE: 01/10/2022 SHFFTNO. EB=1 Lo z 0 0 IIIIIIIIIIm WM 4c Uj 0 14 z 0 PATENTS AND PATENTS PENDING. For more information about the Earthbound Holdown System, visit http://www.holdown.com Copyright C 2022, Earthbound Corporation, All Rights Reserved. DDETAILS" HOL OWN RUN " N M RUN TYPE A RUN TYPE B RUN TYPE A-4 RUN TYPE B-4 WOOD UPLIFT CALCULATED COLLECTED WOOD WOOD UPLIFT CALCULATED COLLECTED WOOD WOOD UPLIFT CALCULATED COLLECTED WOOD WOOD UPLIFT CALCULATED COLLECTED WOOD O FLOOR TENSION DIFFERENTIAL DIFFERENTIAL COMPRESSION FLOOR TENSION DIFFERENTIAL DIFFERENTIAL COMPRESSION FLOOR TENSION DIFFERENTIAL DIFFERENTIAL COMPRESSION FLOOR TENSION DIFFERENTIAL DIFFERENTIAL COMPRESSION 0 LEVEL LOADS LOADS LOADS DOWNLOAD LEVEL LOADS LOADS LOADS DOWNLOAD LEVEL LOADS LOADS LOADS DOWNLOAD LEVEL LOADS LOADS LOADS DOWNLOAD H 5th 6,900 LBS 6,900 LBS 6,900 LBS 12,200 LBS 5th 6,900 LBS 6,900 LBS 6,900 LBS 12,200 LBS 5th ----- ----- ----- ----- 5th ----- ----- ----- ----- Q 4th 6,900 LBS ----- ----- 12,200 LBS 4th 6,900 LBS ----- ----- 12,200 LBS 4th 6,900 LBS 6,900 LBS 6,900 LBS 12,200 LBS 4th 6,900 LBS 6,900 LBS 6,900 LBS 12,200 LBS 0 z O 3rd 6,900 LBS ----- ----- 12,200 LBS 3rd 6,900 LBS ----- ----- 12,200 LBS 3rd 6,900 LBS ----- ----- 12,200 LBS 3rd 6,900 LBS ----- ----- 12,200 LBS N 1- *NOTE = 9'-0" TYPICAL HEIGHT Q 11 y" ® 2nd 13,500 LBS 6,600 LBS 6,600 LBS 24,500 LBS 2nd 9,900 LBS 3,000 LBS 3,000 LBS 24,500 LBS 2nd 13,500 LBS 6,600 LBS 6,600 LBS 24,500 LBS 2nd 9,900 LBS 3,000 LBS 3,000 LBS 24,500 LBS STANDARD TM let MAX PER FLOOR FRAMING, 1st 22,400 LBS 8,900 LBS 8,900 LBS 24,500 LBS let 9,900 LBS ----- ----- 24,500 LBS 1st 22,400 LBS 8,900 LBS 8,900 LBS 24,500 LBS let 9,900 LBS ----- ----- 24,500 LBS tZ U ENDFROM PLUMB CL SHEARFJ WALL ' s7.°4 BLACKJACK DEVICE NOTE: NOTE: NOTE: NOTE: � W SLACKJACK'"' DEVICE/ 2-y2"* MAX PER FLOOR PLATE THIS HOLDOWN RUN SHALL HAVE THE THIS HOLDOWN RUN SHALL HAVE THE THIS HOLDOWN RUN SHALL HAVE THE THIS HOLDOWN RUN SHALL HAVE THE (OR COUPLER) FROM PLUMB TOE NAILING OPTIONAL AT TM BRIDGE BLOCK. NAILING " FLOOR ABOVE BLACKJACK DEVICE/ MUST BE AT ABOVE 25R COMPRESSION BRIDGE MOUNTED 4 -4 COMPRESSION BRIDGE MOUNTED 4 -4 COMPRESSION BRIDGE MOUNTED 4 -4 COMPRESSION BRIDGE MOUNTED 4 -4 (OR COUPLER) I OF BLOCK HEIGHT ONLY. FLOOR JOIST OR MIN. FROM FLOOR PLATE. THE BRIDGE MIN. FROM FLOOR PLATE. THE BRIDGE MIN. FROM FLOOR PLATE. THE BRIDGE MIN. FROM FLOOR PLATE. THE BRIDGE U L SOLID BLOCKS (TYP) FLOOR ABOVE FACE NAILING (TRIMMER) STUDS SHALL HAVE PANEL (TRIMMER) STUDS SHALL HAVE PANEL (TRIMMER) STUDS SHALL HAVE PANEL (TRIMMER) STUDS SHALL HAVE PANEL W z EACH SIDE (TYP). EDGE NAILING AT 3" O.C. SPACING. EDGE NAILING AT 3" O.C. SPACING. EDGE NAILING AT 3" O.C. SPACING. EDGE NAILING AT 3" O.C. SPACING. (n O REF. STUDS (TYP) SEE NOTE #17 FOR REF. STUDS (TYP) PLUMB ALL REQUIREMENTS W 07 Ld (Z > W PLUMB � TM SLACKJACK DEVICE/ � COUPLER (C) 0 � SLACKJACK DEVICE/ (OR COUPLER) (OR COUPLER) W to FLOOR BELOW ROD (R) FLOOR BELOW TM ® 2x FULL LENGTH STUD ® 2x FULL LENGTH STUD S SLACKJACK DEVICELd PLATE 2x BRIDGE TRIMMER 2x BRIDGE TRIMMER ALLOWABLE ROD OFFSET ALLOWABLE ROD OFFSET 51, EB-21E6-2 SJA225 EB-21E6-2 SJA225 N AT PLATFORM FRAMING AT NON PLATFORM FRAMING (10 YELLOW BLACK YELLOW BLACK O TYP. BRIDGE INSTALLATIw ON O P8 P8 DETAIL 2 DETAIL 1 - MOUNT AT 4'-4" (BLACK) MOUNT AT 4'-4" (BLACK) O Q H ABOVE FLOOR 4x6/6x6 ABOVE FLOOR 4x6/6x6 SCALE: NONE EB-2 EB-2 SCALE: NONE EB-2 EB22 BRIDGE BRIDGE - BRIDGE BRIDGE 0 TRIMMERS REQUIRED �� TRIMMERS REQUIRED O O l LLJ 4x WALLS: 72 R5Q o Ld 4x WALLS: 72 R5Q N 2x FULL LENGTH STUD N 2x FULL LENGTH STUD J � J N/A J N/A N 2x BRIDGE TRIMMER N 2x BRIDGE TRIMMER cn SJA225 cn W > SJA225 J o o 6x WALLS: YELLOW BLACK o o _j 6x WALLS: YELLOW BLACK 1 1 a 0 SJA225 SJA225 z Q ®2* P12 : ®2* P12 EB-2 EB-2 YELLOW BLACK EB-2 EB-2 YELLOW BLACK *BRIDGE TRIMMERS SHALL (GRAY) *BRIDGE TRIMMERS SHALL (GRAY)=FR - P8 P8 Q BE 2x MEMBERS ONLY. BE 2x MEMBERS ONLY. MOUNT AT 4'-4" (BLACK) MOUNT AT 4'-4" (BLACK) COLLECTOR COLLECTOR ABOVE FLOOR 4x6/6x6 ABOVE FLOOR 4x6/6x6 STUDS REQUIRED STUDS REQUIRED m N 4x WALLS: N 4x WALLS: BRIDGE BRIDGE - BRIDGE BRIDGE oLLJ Q N w _ I R5 N w _ I R5 �N TRIMMERS REQUIRED 72" R5 c j w �I 4xRWALLSS REQUIRED 72" R5 W o �w o > cn W I 4x WALLS:12 J o Q N/A C55 o Q N/A C55 0� o l- AO z Q z Q Q O� J r c~n SJA225 c~n SJA225 N a- - N/A SJA225 N � J N/A SJA225 Q cn w w w Ll Ll J 6x WALLS: J 6x WALLS: L� LL_ > YELLOW BLACK W LL- - 6x WALLS: W = W 0 0 1 WA MIN YELLOW BLACK L� L� YELLOW BLACK > 6x WALLS: l� o 0 16.5" MIN YELLOW BLACK P12 �� P12 � ®2* P12 4 ®2* P12 U Q LIJ (GRAY) (GRAY) *BRIDGE TRIMMERS SHALL (GRAY) *BRIDGE TRIMMERS SHALL (GRAY) li 4 2x s TOTAL 942:x TSTOMTAL U BE 2x MEMBERS ONLY. BE 2x MEMBERS ONLY. z COLLECTOR COLLECTOR COLLECTOR COLLECTOR STUDS REQUIRED STUDS REQUIRED STUDS REQUIRED STUDS REQUIRED �pppp00 0 N 4x WALLS: N 4x WALLS: N 4x WALLS: N 4x WALLS: DO 00 \R5 R5 R5 R5U n w .M:...�/�Op NOTES: o o o o o o o o O\ .• of WAs ` ..� N/A N/A N/A N/A O •�� h6yc . p NOTE: SOLID BLOCKING, PROVIDE ENOUGH SOLID � Q C75 Q r C65 Q r C75 Q C65 1. FOR HOLDOWN ANCHOR BOLT REINFORCING LL_ J I- J J I- J REQUIRED SEE DETAIL 4/S7.04. BLOCKING IN JOIST SPACE TO MATCH WIDTH OF O U' > 6x WALLS: SJA217 �' > 6x WALLS: SJA216 �' > 6x WALLS: SJA217 `n > 6x WALLS: SJA216 ❑ 2. FOR HOEDOWN ANCHOR PLATES REQUIRED ALL COMPRESSION STUDS OR POSTS OF THE o o J 16.5" MIN - BLUE BLUE o o J 16.5" MIN - BLUE GRAY o o J 16.5" MIN - BLUE BLUE o o J 16.5" MIN - BLUE GRAY �, ❑ SEE DETAIL 5/S7.04. WALL BELOW. ................... � �, �S:TATAL � P 12 �, �S:TATA I P 12 � + � P 12 � �S:TJTAL I P 12 00o G�T�R'�6E�����• oO Q k42x: (GRAY) k42x: L I (GRAY) 942-x s TOTAL (GRAY) k42x: I (GRAY) 000F/0NAL\000 REFERENCE STUDS 9" ® STANDARD 9" 0 STANDARD 3 3 3 3 °Ov❑�pp0� 10I FRAMING, 1/S7.04 FRAMING, 1/S7.04 w COLLECTOR COLLECTOR COLLECTOR _ _ COLLECTOR _ '�� CODUPLER SLACKJACK DEVICE TM _ STUDS REQUIRED - EB-2 EB-2 STUDS REQUIRED - EB-2 EB-2 _ STUDS REQUIRED EB-2 EB-2 STUDS REQUIRED EB-2 EB-2 N 4x WALLS: TYP 4x WALLS: TYP 4x WALLS: TYP 4x WALLS: TYP AB & ROD (R) FULLY I I SLACKJACK DEVICE Cn W _ I R7 l W _ I R6 cn Ld _ I R7 l W _ I R6 n SEATED IN COUPLER PLATE ' PLATE J N/A C97HS � N/A C66HS � N/A C97HS � N/A C66HS �, N END OF II !!^^ pF O �F- O �� O OF- O SHEAR WAL I I V J Q Q - � Q f � Q NUT &WASHER Z (n� J (n� J (n� J (n� -i N-PH FIND. PLATE N f 0- LL. LL. > 6x WALLS: SJA419 > 6x WALLS: SJA216 > 6x WALLS: 0 1sI 5 o o -j SJA419 � J 6x WALLS: SJA216 cfl I� X o RED WHITE o J 16> 5 BLUE GRAY 16> 5 MIN RED WHITE o 16> 5 MIN BLUE GRAY c `n r ` ° ANCHOR BOLT AS z SOLID BLOCKING I (3) 2x PLATES W N + � 0O 4 r7 wp° a SPECIFIED BY w J PER STRUCT. ENGR. N e; STRUCTURAL PLANS. o REQUIREMENTS. ROD (R) 6x6 6x6 N N N P12-9 P12 P12-9 P12 � � � g L (GRAY) sx6 6x6 (GRAY) 6x6 6x6 (GRAY) 6x6 6x6 (GRAY) °' co 4 a 1/2"x4" SQ. PLATE LdQ COLLECTOR 2X PLATES COLLECTOR 2X PLATES COLLECTOR 2X PLATES COLLECTOR 2X PLATES CD CD ANCHOR CHAIR 2 2x PLATES STUDS RE UIRED (TYP) STUDS RE UIRED (TYP) STUDS RE UIRED (TYP) STUDS RE UIRED (TYP) (� 00 ( ) M N 4x WALLS: �cn N 4x WALLS: N 4x WALLS: �cn N 4x WALLS: ROD (R) <nLL! I lw I cnw I lw I N x O 1- , O� r O� , 0� O O O O O N A N A N A N A L� � / 12 R9 / 12 R6 / 12 R9 / 12 R6 Q a Q a Q r f LEAVE 3 THREADS MIN.4V O OPTIONAL EXPOSED4-1 O (nn a- J C109HSG N W C66HSG N C109HSG C66HSG NAILS (TYP) _ > 6x WALLS: > 6x WALLS: > 6x WALLS: > 6x WALLS: U o o � 12„ N10G o o-i 12" N6G o o J 12" N10G o o-i 12" N6G i TYP. SLACKJACK' INSTALLATION TYP. SLACKJACK'"' INSTALLATION z & WBASHER & WBASHER & WASHER & WASHER AT PLATFORM FRAMING AT NON PLATFORM FRAMING Q 6x6 6x6 6x6 sx6 6x6 L 6x6 6x6 Z TYP. ANCHOR BOLT INSTALLATION 5 I EB-2 EB-2 I EB-2 EB-2 I EB-2 EB-2 I EB-2 EB-2 a o_ DETAIL 4 DETAIL 3 I ..,.:., AB PLT: I AB: R10G AB PLT: I AB: R6G AB PLT: I AB: R10G AB PLT: I AB: R6G o W SCALE: NONE EB-2 EB-2 SCALE: NONE EB-2 EB-2 „ " " " " „ " U) Z 1 /2 x4„ SQ. _ _ 4 1 /2 x4 SQ. _ _ 4 1 /2 x4 SQ. _ _ 4 1 /2 x4 SQ. _ _ 4ci 0 a) c-,I W N CHR. HT: 1-1/2" EB-2 EB-2 CHR. HT: 1-1 /2" Eg_2 Eg_2 CHR. HT: 1-1 /2" Eg_2 Eg-2 CHR. HT: 1-1 /2" EB-2 EB-2 0 0'00 w LLJ Z �� O U CV co z a::�o A B A-4 B-4 Z o w O W 000 0 3 W W Z Lo LL W � O > ca� 0) O Z O N = c ti 3 O ANCHOR BOLT o O 12" LOCATION ZONE END OF (TYP) 00 SHEAR WALL ~ N Z r aN W z U TYP. ANCHOR BOLT PLAN M DETAIL B � O SCALE: NONE EB-2 EB-2 Im ANCHOR BOLT NOTES: EB CORP JOB NO: x 1. CONTRACTOR SHALL BE RESPONSIBLE FOR 20491 lImon COORDINATION OF WALL TYPE AND FRAMING LAYOUT BEFORE LOCATING ANCHOR BOLTS IN CONCRETE. WM 2. ALL DIMENSIONS ARE TYPICAL U.N.O. SHEET TITLE: 4 EARTHBOUND SEISMIC Uj HOLDOWN SYSTEM INSTALLATION DRAWINGS ON N a- REVIEWED IAPMO ER-0429 o r.. August 27, 2022 7- 0 � 0 Reviewed by: DBeck �W N BECK &ASSOCIATES, PLLC DATE: 01 /10/2022 LI_ 0 O N >- CT z RECEIVED SHEET NO. JO L BLD2021-0088 DEF SUB3- Aug 23 2022 0 OF HOLD DOWNS CILOP M ETSERVI DEVELOARTMENVICES EB=2 Q PATENTS AND PATENTS PENDING. For more information about the Earthbound Holdown System, visit http://www.holdown.com Copyright ® 2022, Earthbound Corporation, All Rights Reserved. LEVEL 2 FLOOR PLAN THIS LAYOUT SHEET IS BASED ON HOLDOWN RUN LOCATIONS SHOWN ON STRU 'TL RAL PLAN SHEET "'S^:2.02W". THE CONTRACTOR SHALL NOTIFY EARTHBOUND IMMEDIATELY IF REVISED PLANS THAT MAY AFFECT THE QUANTITY AND LOCATION OF RUNS SHOWN ARE ISSUED. O OK -(:L EARTHBOUND SYSTEM LAYOUT DISCLAIMER 1. THIS LAYOUT SHEET IDENTIFIES EARTHBOUND SYSTEM RUNS FOR CONVENIENCE TO THE SYSTEM INSTALLER AND PROVIDED FOR REFERENCE ONLY. REFER TO THE CONSTRUCTION PLANS FOR ALL OTHER INFORMATION. 2. EARTHBOUND CORPORATION HAS NOT CONFIRMED AND IS NOT RESPONSIBLE FOR THE DESIGN, ENGINEERING, CALCULATIONS OR DERIVATION OF STRUCTURAL FORCES RELATED TO THE BUILDING. ANY DESIGN OR DEMAND LOAD INFORMATION USED OR SHOWN ON THESE DRAWINGS HAS BEEN TAKEN FROM THE CONSTRUCTION DOCUMENTS AND HAS NOT BEEN CONFIRMED BY EARTHBOUND. 3. THIS LAYOUT IS NOT FOR CONSTRUCTION WITHOUT SUBSTANTIATION OF REVIEW BY THE RESPONSIBLE ENGINEER OF RECORD AND THE GOVERNING BUILDING JURISDICTION. 4. THIS LAYOUT IS SPECIFIC TO THE EARTHBOUND SYSTEM AND IS NOT APPLICABLE TO OTHER TIEDOWN SYSTEMS. 5. REFER TQ-.,c,,HEETS,EB_,1, M FOR ADDITIONAL NOTES AND INFORMATION. BLD2021-0088 DEF SUB3- HOLD DOWNS RECEIVED Aug 23 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT EARTHBOUND SYSTEM LOCATION LAYOUT SHEET