Loading...
FIR2023-0040+Fire_Alarm_Equipment_Specification_Sheets+4.26.2023_10.49.16_PM+3508369RECEIVED Apr 28 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FI R2023-0040 Washington Alarm, Inc. Providing Quality, Service and Integrity to the Pacific Northwest Since 1943 ANTHOLOGY OF EDMONDS 21200 72ND AVE W EDMONDS, WA, 98026 FIRE ALARM & TWO WAY COMMUNICATION SYSTEM JOB 21836-1 REVO 1420 King St, Ste E UL Listed Central Station Bellingham, WA, 98229 Licensed and Bonded Electrical Contractor WASHIA1282C3 Phone: (206) 328-3288 Fax: (206) 322-7214 www.washingtonalarm.com NETWORK FIRE ALARM CONTROL PANEL FX-4003-12N fly FIeXNet FX-4003-12N and DSPL-420DS (sold separately) Display, Backbox and Door are sold separately Description For projects where flexibility is needed, Micom's FleX-Net FX-4000 Series is a powerful multi -protocol solution. FX-4003-12N is designed to meet virtually any application of detection, control, notification, and emergency communications. Features such as fire detection & alarm, audio/voice evacuation, BACnet, Boolean logic, networking, and graphical workstation support allow this modular solution to accommodate projects from the simplest systems up to the most complex solutions. • FX-4003-12N supports multiple intelligent protocols: - MIX-4000 Devices -Advanced Protocol (AP) - Classic Loop Interface Protocol (CLIP) • Multiple User Interface Options including: - 80 characters or 960 character back -lit LCD with the user-friendly menu. - LED displays adders - Up to 7 remote annunciators per node NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Features • Main Processor Board with built in Network card interface, Voice Evacuation System Interface, and IP Port for OpenGN Workstation or BMS Integration • Supports both 80 character and 960 character back -lit LCD displays with user friendly menu • Expandable up to 8 SLC • Each SLC current capability is 200mA in standby and 400mA in alarm. SLC Maximum line resistance 40 Ohms and maximum line capacitance 0.47uF • Sub -addressing to optimize the number of devices in each loop • Four Style Z/Y (Class A/B) Notification Appliance Circuits rated at 1.7 Amps each with built-in sync protocol • Class A, Class X or Class B analog loop(s) • Compatible with conventional detectors using DM-1008A Eight Initiating Circuit Module or MGC MIX-4042 Conventional Zone module, refer to document LT-1023 for compatible detectors • User Interface Tags and Labels in English, French, Italian, Spanish, Portuguese, Arabic*, Hebrew*, Chinese*, Japanese*, Korean* and Russian* (*needs DSPL-2440DS or RAXN-4000LCDG) • Tags only: it accepts all languages supported by Windows 10 (requires DSPL-2440DS or RAXN-4000LCDG) • Boolean Logic Engine for complex sequences of Operations • Four Alarm Queues with selector switches and LEDs for Alarm, Supervisory, Monitor and Trouble • RS-232 output for remote system printer or terminal • RS-485 port for system expansion • Ethernet port for OpenGN, BACNet and Webserver • Built in BACNet for BMS System Integration • Built in Webserver for Remote Event Notification • Integration with QX-Mini Audio Panels • Two Event History Logs; one for Alarm -related events (5000 events) and one for all events (5000 events) • System can be configured without taking the panel off-line • Supports three configuration files (current, previous and next configuration) with "hot swap" support • Remote diagnostics via a built-in web server • UL listed for Smoke Control (UUKL). S Tl� NYC FM Fire Dept APPROVED CATALOG NUMBER 9209 Features cont'd MIX-4000 Devices Features For new or retrofit expansion of existing applications, supports up to 240 MIX-4000 devices per SLC Supports: • Photo, Heat, and Multi -criteria Sensors • Optional Built -In Isolation on Sensors • Multiple Input and Multiple Output modules • Group activation on the output to speed up actions on the outputs AP Protocol Features Advanced Protocol (AP) supports up to 318 devices per SLC (159 sensors & 159 modules). Supports: • Smoke, Heat and Fire/CO detection • Low Frequency 520 Hz sounder base support on both the addressable loop and through the audio/voice evacuation system. • Interrupt operation on input side to speed detection of an event communication back to the panel • Group activation on the output to speed up actions on the outputs CLIP Protocol Features: • Address range for sensors S1-S99 - address range for modules M1-M99. • Wide range of addressable devices available. Electrical Specifications Primary Input Power 120VAC 60Hz / 240VAC 50Hz 4 Amps / 2 Amp (primary) Battery Type 24VDC Gel Cell / Sealed lead acid Networking Features The network configuration allows multiple FleX-Net FX-4000 Series control panels to be connected using supervised Class A/B circuits to expand the available SLCs, input circuits, visual indication zones, programmable notification appliance circuits, relay outputs and monitor points in the application. The network interface module creates a robust peer -to -peer network via a proprietary protocol that ensures network segments operate independently in case of network impairment. The high baud rate of the network allows for multiplexing of control, audio, and telephony communications over a single copper or fiber interface using advanced compression algorithms. Twisted -Pair Copper, Single -Mode Fiber & Multi -Mode Fiber networking is supported. • Up to 63 nodes • Peer -to -peer network communications • Fully integrated digital network audio and control over a single pair of copper wire or fiber optic cable (single or multi -mode) • Remote diagnostics via built-in web server and standard Ethernet port in every node • Style 4 (Class B) or Style 6 or 7 (Class A) network wiring configuration NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 %� %� iTHIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 2 of 12 // ki,. M rcom ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Enclosures UB-1024DS DOX-1024DSB UB-1024DS Universal Backbox The UB-1024DS Universal backbox houses the FX-4003-12N and provides space to mount up to 17 AH batteries. A DOX-1024DSB door is ordered separately. Dimensions (minus built-in trim ring): 26" H x 14.5" W x 4.2" D DOX-1024DSB Door The DOX-1024DSB mounts on the UB-1024DS backbox. The door features the universal CAT-30 lock. 010"* NE HER ROTECTED 1313-1002WP(R)A — Outdoor Weather Protected Enclosure The 1313-1002WP(R)A is a complete enclosure that comes with either a RED or WHITE door, a black back -box, two keys and a durable lock at the top of the door. The door comes hinged to the bottom side of the box for added weather protection. The box is capable of handling one RAM-1032TZDS-CC Main Annunciator Chassis which provides up to 32 points of annunciation and one RAX1048TZDS-CC Adder Annunciator, which provides up to 48 points of annunciation. RAM-1032TZDS-CC and RAX1048TZDS-CC are ordered separately to match the UL, ULC installation requirements. Note: there is no need for thermostat or heater. RAM-1032TZDS-CC and RAX-1048TZDS-CC must be ordered separately to match UL, ULC installation requirements. .A* BB-1001WP(R)A— Outdoor Weather Protected Enclosure The 1313-1001 WP(R)A is a complete enclosure that comes with either a RED or WHITE door, a black back -box, two keys and a durable lock at the top of the door. The door comes hinged to the bottom side of the box for added weather protection. The box is capable of handling one RAM-1032TZDS-CC Main Annunciator Chassis which provides up to 32 points of annunciation. RAM-1032TZDS-CC is ordered separately conform with the UL, ULC installation requirements. Note: there is no need for thermostat or heater. RAM-1032TZDS-CC must be ordered separately to match UL, ULC installation requirements. 1313-1001 / 2 / 3 / 8 / 12 — Remote Annunciator Enclosures The BB-1000 Series comes complete with a backbox, door and hinge. The enclosures doors come with Lexan windows, two keys and a durable lock. The enclosures can handle the RAM-1032TZDS, RAX-1048TZDS, Main Annunciator Chassis. BB-1 001 D / DR / DS / DB 9" H x 12.75" W x 1.85" D 1313-1002D/DR/DS/DB 18"HX12.75"WX1.85"D 1313-1003D / DR / DS / DB 26.4" H x 12.75" W x 1.85" D 1313-1008D / DR / DB 33" x 22.5" W x 1.85" D 1313-10012D / DR / DB 45" H x 22.5" W x 1.85" D NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 %� %� iTHIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 3 of 12 // ki,. M rcom ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Displays DSPL-420DS Main Display Module The DSPL-420DS Main Display Module provides the FX-4003-12N with a 4-line by 20-character backlit LCD display, Common Controls buttons and Four Status Queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitor. The DSPL-420DS occupies one display position in the FX-4003-12N inner door. DSPL-420-16TZDS Main Display Module The DSPL-420-16TZDS Main Display Module provides a 4-line by 20-character backlit LCD display, Common Control buttons and Four Status Queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitoring with an additional 16 LED points of annunciation. The DSPL420-16TZDS occupies one display position in the FX-4003-12N inner door. DSPL-2440DS Graphical Main Display Module The DSPL-2440DS Graphical Main Display Module provides the FX-4003-12N with a 24-line x 40-character backlit LCD display, common controls buttons and four status queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitor. The DSPL-2440DS occupies one display position in the FX-4003-12N inner door. NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 %� %� iTHIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 4 of 12 // ki,. M rcom ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Remote Annunciators RAXN-4000LCD Remote LCD Annunciator The RAXN-4000LCD Remote LCD Annunciator is equipped with a 4-line x 20-character back -lit alphanumeric LCD display that provides an exact replica of the main FleX-Net fire alarm control panel display. The RAXN-4000LCD occupies one display position in the BB-1000 or BB-5000 Series enclosures CONFORMAL COATED PRODUCT RAM-1032TZDS-CC Conformal Coated Main Remote LED Annunciator The RAM-1032TZDS-CC Conformal Coated Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM-1032TZDS- CC has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. The RAM-1032TZDS- CC occupies one display position in the BB-1001WP(R)Aor BB-1002WP(R)A enclosures. RAM-1032TZDS Main Remote LED Annunciator The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM-1032TZDS has indicators forA.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. The RAM-1032TZDS occupies one display position in the BB-1000 or BB-5000 enclosures. RAXN-4000LCDG Remote Graphic LCD Annunciator The RAXN-4000LCDG Remote Graphic LCD Annunciator is equipped with a 24-line x 40-character back -lit graphical LCD display that is used to display 9 events per page. Each event is displayed over 2 lines with 40 characters per line allowing emergency information to be displayed in easy to read format. The RAXN-4000LCDG occupies one display position in the BB-1000 or BB-5000 Series enclosures. )RMAL ,ED )UCT RAX-1048TZDS-CC Conformal Coated Programmable LED Annunciator Module The RAX-1048TZDS-CC Conformal Coated Programmable LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-1048TZDSCC connects to the main panel or either the RAXN-4000LCD or RAM-1032TZDS when mounted remotely. The RAX-1048TZDS-CC occupies one display position in the BB-1 002WP(R)A Series enclosures. RAX-1048TZDS Programmable LED Annunciator Module The RAX-1048TZDS Programmable LED Annunciator Module provides 48 programmable bi-colored LEDs. The RAX-1048TZDS connects to the main panel or either the RAXN-4000LCD or RAM-1032TZDS when mounted remotely. The RAX-1048TZDS occupies one display position in the FX-4003-12N, BB-1000 or BB-5000 Series enclosures. NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 %� %� iTHIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 5 of 12 // ki,. M rcom ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Graphic Annunciator Driver Modules MGD-32 Master Graphic Driver Module For use with FX-401, FX-1000, FX-2000 and FX-4000 Series Fire Alarm Control Panels. The MGD-32 Master Graphic Driver Module provides common control inputs for the switches such as System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test and Acknowledge Graphics Software ,` OPEN GRAPHIC'" `�J NAVIGATOR AGD-048 Adder Graphic Annunciator Adder Driver Board The AGD-048 Adder Graphic Driver Module can be used with the MGD-32 to support an additional 48 supervised outputs. The AGD-048 mounts in a graphic annunciator wall box or in the BB-5000 enclosures. Open Graphic Navigator (OpenGN) Open Graphic Navigator (OpenGN) is a centralized fire alarm management system that provides building or campus monitoring. As a powerful integration tool, OpenGN allows operators to monitor remote sites from multiple workstations located anywhere in the world. OpenGN displays monitored buildings and campuses in both 2D and 3D representations, and is highly customizable. Model OGN-FLSLIC-ONE Single Fire Alarm Control Panel License Requires: OGN-KEY (sold seperately) OGN-FLSLIC-EXP Fire Alarm Control Panel License for 2-9 Connections Requires: OGN-KEY(sold seperately) OGN-FLSLIC-STD Fire Alarm Control Panel License for 10-99 Connections Requires: OGN-KEY (sold seperately) OGN-FLSLIC-ENT Fire Alarm Control Panel License for 100+ Connections Requires: OGN-KEY (sold seperately) OGN-KEY OGN License Key Stick NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 %� %� iTHIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 6 of 12 // ki,. M rcom ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Programmable Modules Adder Loop Controller Modules IPS-2424DS Programmable Input Switches Module The IPS-2424DS provides 24 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The IPS-2424DS connects to the main panel or the RAXN-4000LCD when mounted remotely. The IPS-2424DS occupies one display position in the FX-4003-12N, BB-1000 or BB-5000 Series enclosures. FDX-008W/KI Fan Damper Module The FDX-008W/FDX-008WKI Fan Damper Control Module provides individually programmed circuits which can be used for fan or damper control. The FDX-008W/FDX-008WKI connects to the main panel or the RAXN-4000LCD and occupies one display position in the FX-4003-12N, BB-1000 or BB-5000 Series enclosures. IPS-4848DS Programmable Input Switches Module The IPS-4848 provides 48 programmable switches that can be configured for ancillary functions such as zone bypass or added common control functions. The IPS-4848DS connects to main control unit or the RAXN-4000LCD when mounted remotely. The IPS-4848DS occupies one display position in the FX-4003-12N, BB-1000 or BB-5000 Series enclosures. �J- lei � w ALCN-960MISO Isolated Quad Loop Adder Module For MIX-4000 devices, the ALCN-960MISO Isolated Quad Loop Adder Module provides two Signaling Line Circuits (SLC) with ground fault detection to the system consisting of 240 MIX-4000 devices per loop. The ALCN-960MISO can be expanded with the use of the ALCN-960D Daughter Board Module. The ALCN-960MISO occupies one module slot. ALCN-960D Daughter board forALCN-960MISO For MIX-4000 devices, the ALCN-960D Daughter Board provides an additional two SLC loops when connected to the ALCN-960MISO Isolated Quad Loop Adder Module. The daughter board mounts on top of the ALCN-960MISO. ALCN-4792MISO Isolated Quad Loop Adder Module The ALCN-4792MISO Isolated Quad Loop Adder Module provides two Signaling Line Circuits (SLC) with ground fault detection to the system consisting of 159 Analog Sensors and 159 Addressable Modules per loop. The ALCN-4792MISO can be expanded with the use of the ALCN-792D Daughter Board Module. The ALCN-4792MISO occupies one module slot. ALCN-792D Daughter board for ALCN-4792MISO The ALCN-792D Daughter Board provides an additional two SLC loops when connected to the ALCN-4792MISO Isolated Quad Loop Adder Module. The daughter board mounts on top of the ALCN-4792MISO. NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 ����`` • THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 7 of 12 Mirco 11 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Adder Hardwire Modules Network Controller Modules DM-1008A Eight Initiating Circuit Module The DM-1008Aprovides 8 Style B (Class B) or Style D (Class A) Initiating Circuits configurable for Alarm, Supervisory or Trouble zones. The DM-1008A occupies one module slot. SGM-1004A Four Notification Appliance Circuit Module The SGM-1004A provides up to four indicating circuits each rated at 1.7 Amps to signal devices such as strobes, bells, horns, etc. Each of the indicating circuits can be configured as nonsilenceable (steady) or silenceable. In addition, each circuit comes with an individual trouble indicator. RM-1008A Eight Relay Circuit Module The RM-1008A provides the system with eight individual configurable relays per module. Each relay provides one Form C contact rated at 28 VDC @1 Amp (resistive load) as well as a Green LED to indicate that the relay is active. The RM-1008A occupies one module slot FNC-2000 Fire Network Controller Module The FNC-2000 provides network capability to the system. One Fire Network Controller Module is required per network node panel. In addition the FNC-2000 provides an interface for adding an optional "FOM-2000-UM" Fiber Optic Network Adder Module. The FOM-2000- UM allows for single -mode or multi -mode fiber optic communication on a FleX-Net. FOM-CONN-MM 1Is] di9K07►10WLVAI FOM-2000-UM FOM-2000-UM Fiber Card Universal Mode Allows for single -mode or multi -mode fibre optic communica- tion on a Flex -Net network. Add FOM-CONN-SM and FOM- CONN-MM FOM-CONN-MM Fiber Optic Connector Multi -Mode Fibre Optic Module Connector Multi -mode (pack of 2). Must use a FOM-2000-UM FOM-CONN-SM Fiber Optic Connector Single -Mode Fibre Optic Connector Single Mode (pack of 2). Must use a FO M-2000-U M NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 %� %� iTHIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 8 of 12 // ki,. M rcom ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Power Supply Expansion Accessories INX-10A Intelligent Booster Power Supply Mircom's INX-10A is an Intelligent NAC expander/ power supply that works with listed compatible Intelligent fire alarm control panels. Available in a 10 Amp configuration, the INX-10A can extend the power capabilities of existing notification appliance circuits as well as provide power for other ancillary devices. In addition, the INX-10A has the ability to operate with any UL/ULC Listed 24 VDC fire alarm control panel to provide Notification Appliance Circuit expansion. Adder Auxiliary Modules UDACT-300A Digital Alarm Communicator Module The UDACT-300A Digital Communicator allows the system to transmit addressable point information to a central station. The UDACT-300A occupies one module slot. s PR-300 Polarity Reversal/City Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city tie module, the PR300 provides an interface between the control panel indicating circuits and a master box. It provides off -premises signal transmission for systems that must comply with NFPA requirements forAuxiliary Protective Systems. As a polarity reversal module, the PR-300 provides an interface between the control panel and a reverse polarity receiver. 4 UIMA4 — Interface for Configuring MGC Fire Panels The UIMA4 is an interface for configuring FleX-Net FA-300, FX-401, FX-2000, FX-3500, FX-3318, FX-4000, QX-5000, and UDACT-300. The UIMA4's ribbon cable can be disconnected and replaced — the replacement part number is RPL-WC-25022 (it comes with 3 replacement cables). The UIMA4 interface has 3 connectors: 9 pin male serial connector, USB B female connector, and 10 pin female connector s RTI-1 — Trouble Remote Indicator Mircom's Remote Trouble Indicator provides remote annunci- ation of fire alarm troubles. The RTI-1 mounts onto a standard single gang electrical box. The RTI-1 can be used with any of Mircom's fire alarm control panels. MP-300 — End of Line Plates Mircom's MP-300 is a 3.91K End Of Line resistor for use with Mircom conventional panels and detection circuits. NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND Page 9 of 12 lki, M i r c o m ° NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Current Consumption Model Description FleX-Net FX-4000 Series Network Lobby Control and Floor Panels - Integrated Fire and Audio Systems FX-4003-12N Compact Main Network Control Unit (12 Amp) 0.310 0.733 Displays DSPL-420DS 4 x 20 Main LCD Display for FX-4003-12N 0.025 DSPL-420-16TZDS 4 x 20 Main LCD Display for FX-4003-12N w/16 LEDs 0.046 DSPL-2440DS Graphical Main Display for FX-4003-12N LO.024 0.035 Adder Loop Controller Modules ALCN-4792MISO Isolated Quad Loop Controller Module (for Mircom CLIP and Select Series Devices) 0.130 0.145 ALCN-792D Daughter board forALC-4792MISO Isolated Quad Loop Controller Module 0.130 0.145 ALCN-960MISO Isolated Quad Loop Controller (for MIX-4000 Devices) 0.130 0.145 ALCN-960D Adder Hardwire Modules DM-1008A Daughter Board for ALCN-960M ISO Eight Class B (Style B) or 4 Class A (Style D) Initiating 0.130 0.080 0.145 1 zone active: 0.125 2 zones active: 0.170 4 zones active: 0.275 6 zones active: 0.370 8 zones active: 0.465 SGM-1004A Four Class A/B (Style Z/Y) Notification Appliance Circuit Module (Rated at 1.7 Amps per circuit) 0.060 0.258 RM-1008A Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) 0.025 0.150 Adder Auxiliary Modules UDACT-300A Digital Alarm Communicator Transmitter/Dialer Module 0.045 0.120 PR-300 Polarity Reversal and City Tie Module 0.035 0.300 Programmable Modules IPS-2424DS Programmable Input Switches Module c/w 24 selector switches and 24 bi-coloured LEDs 0.010 0.015 IPS-4848DS Programmable Input Switches Module c/w 48 selector switches and 48 bi-coloured LEDs 0.010 0.022 FDX-008W Fan Damper Control Module c/w 8 programmable switches 0.015 0.035 FDX-008WKI Remote Annunciators RAXN-4000LCD Fan Damper Control Module Remote LCD Annunciator 0.015 0.139 0.035 0.164 RAXN-4000LCDG Remote Graphic LCD Annunciator 0.117 0.150 RAM-1032TZDS Main Remote LED Annunciator c/w 32 Bi-Colored LEDs 0.050 32 zones active: 0.300 RAM-1032TZDS-CC Conformal coated 32 zone remote LED annunciator with trouble LEDs 0.050 32 zones active: 0.300 RAX-1048TZDS Adder Annunciator Chassis c/w 48 Bi-Colored LEDs 0.022 48 zones active: 0.262 RAX-1048TZDS-CC Conformal coated Adder Annunciator Chassis c/w 48 Bi-Colored LEDs 0.022 48 zones active: 0.262 MGD-32 Graphic Annunciator 0.035 1.6 AGD-048 Graphic Annunciator Adder Driver Board 0.035 # of LEDs x 4mA Network Controller Modules ANC-4000 Audio Network Controller Module 0.255 0.265 TNC-5000 Telephone Network Controller Module 0.195 0.215 FNC-2000 Fire Network Controller Module 0.190 0.190 FOM-CONN-MM Fibre Optic Module Connector Multi -mode (pack of 2). Must use a FOM-2000-UM 0.042 0.042 FOM-CONN-SM Fibre Optic Connector Single Mode (pack of 2). Must use a FOM-2000-UM 0.016 0.016 Accessories RTI-1 Trouble Remote Indicator 0.035 0.035 NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 �`���`` n/�' THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND Page 10 of 12 ,/ M irCom NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Ordering Information ModelDescription FX-4003-12N Compact Main Network Control Unit (12 Amp) DSPL-420DS 4 x 20 Main LCD Display for FX-4003-12N DSPL-420-16TZDS 4 x 20 Main LCD Display for FX-4003-12N w/16 LEDs DSPL-2440DS Enclosures UB-1024DS Graphical Main Display for FX-4003-12N Universal Back Box for Compact Main Control Units DOX-1024DSR/DSB Universal Door for UB-1024-DS Back Box, Red BB-1001 D/DR/DS/DB Remote Annunciator Enclosure Houses one module. "D" White, "DR" Red, "DS" Stainless Steel, or "DB" for Black Door. BB-1002D/DR/DS/DB Remote Annunciator Enclosure Houses two module. "D" White, "DR" Red, "DS" Stainless Steel, or "DB" for Black Door. BB-1003D/DR/DS/DB Remote Annunciator Enclosure Houses three module. "D" White, "DR" Red, "DS" Stainless Steel, or "DB" for Black Door. BB-1008D/DR/DB Remote Annunciator Enclosure Houses eight modules. "D" White, "DR" Red or "DB" for Black Door. BB-1012D/DR/DB Remote Annunciator Enclosure Houses twelve modules. "D" White, "DR" Red or "DB" for Black Door. BB-1001 WP(R)A Weather Protected Enclosure Enclosure Houses one module. White. BB-1001 WPRA for red. BB-1002WP(R)A Weather Protected Enclosure Enclosure Houses two module. White. BB-1 002WPRA for red. ALCN-4792MISO Isolated Quad Loop Controller Module (for Mircom CLIP and Select Series Devices) ALCN-792D Daughter board forALC-4792MISO Isolated Quad Loop Controller Module ALCN-960MISO Isolated Quad Loop Controller (for MIX-4000 Devices) ALCN-960D Adcl�&rdwire Modules DM-1008A Daughter Board for ALCN-960M ISO Eight Class B (Style B) or 4 Class A (Style D) Initiating SGM-1004A Four Class A/B (Style Z/Y) Notification Appliance Circuit Module (Rated at 1.7 Amps per circuit) RM-1008A Adder Auxiliary Modules UDACT-300A Eight Relay Circuit Module c/w eight form C relays (Rated for 28 VDC @ 1 Amp max. per relay) Digital Alarm Communicator Transmitter/Dialer Module PR-300 ModulesProgrammable IPS-2424DS Polarity Reversal and City Tie Module Programmable Input Switches Module c/w 24 selector switches and 24 bi-coloured LEDs IPS-4848DS Programmable Input Switches Module c/w 48 selector switches and 48 bi-coloured LEDs FDX-008W Fan Damper Control Module c/w 8 programmable switches FDX-008WKI Fan Damper Control Module INX-10A Intelligent Booster Power Supply RAXN-4000LCD Remote LCD Annunciator RAXN-4000LCDG Remote Graphic LCD Annunciator RAM-1032TZDS Main Remote LED Annunciator c/w 32 Bi-Colored LEDs RAM-1032TZDS-CC Conformal coated 32 zone remote LED annunciator with trouble LEDs RAX-1048TZDS Adder Annunciator Chassis c/w 48 Bi-Colored LEDs RAX-1048TZDS-CC Conformal coated Adder Annunciator Chassis c/w 48 Bi-Colored LEDs MGD-32 Graphic Annunciator AGD-048 Graphic Annunciator Adder Driver Board NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 9209 ����`` ' THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND Page 11 of 12 M Ircom NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Ordering Information cont'd Model Graphic Annunciator Driver Modul OGN-FLSLIC-ONE Single Fire Alarm Control Panel License (Price per connection) Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel connections OGN-FLSLIC-EXP Fire Alarm Control Panel License for 2-9 Connections (Price per connection) Requires: OGN-KEY(sold seperately) Contact us for non-Mircom panel connections OGN-FLSLIC-STD Fire Alarm Control Panel License for 10-99 Connections (Price per connection) Requires: OGN-KEY (sold seperately) Contact us for non-Mircom panel connections OGN-FLSLIC-ENT Fire Alarm Control Panel License for 100+ Connections (Price per connection) Requires: OGN-KEY (sold separately) Contact us for non-Mircom panel connections OGN-KEY OGN License Key Stick Fire Alarm Network BACnet MGC-LIC-BACNET Single User License Unlocks BACnet port on one network node per license MGC-LIC-WEBSERVER Unlocks WEBSERVER port on one network node per license FNC-2000 Fire Network Controller Module FOM-2000-UM Allows for single -mode or multi -mode fibre optic communication on a Flex -Net FX-4000 Series network. Add FOM- CONN-SM and FOM-CONN-MM FOM-CONN-MM Fibre Optic Module Connector Multi -mode (pack of 2). Must use a FOM-2000-UM FOM-CONN-SM Fibre Optic Connector Single Mode (pack of 2). Must use a FOM-2000-UM UIMA4 Interface for Configuring MGC Fire Panels MGC-CONFIG-KIT4 Fire Panel Configuration KIT with UIMA4 RTI-1 Trouble Remote Indicator MP-300 End of Line Plates M i room U THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates ��U For complete and accurate technical information relating to Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 0�� performance, installation, testing and certification, refer to technical 0Telephone: (905) 660-4655 Toll Free: (888) 660-4655 `gyp _ literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 9209 Rev. 7 MAIN DISPLAY MODULE Description The DSPL-420DS Main Display Module provides a 4 line by 20-character backlit LCD display, Common Control buttons and Four Status Queues with selector switches and LEDs for Alarm, Supervisory, Trouble and Monitor. The DSPL-420DS occupies one display position in the BBX-FXMNS enclosure. The DSPL-420DS comes with a user-friendly menu. Common Control switches and/or indicating LEDs for System Reset, Signal Silence, Fire Drill, Acknowledge, General Alarm, Lamp Test, A.C. On, Pre -Alarm and Ground Fault. Ordering Information DSPL-420DS Features • New robust and tactile membrane switches • 4 line by 20-character LCD display • Backlit display • User-friendly Menu • Common Control buttons with selector switches and LEDs • Four Status Queues: Alarm, Supervisory, Trouble and Monitor • Occupies one display position in the BBX-FXMNS enclosure • Compatible with FX-2000, FleX-NetT1 (FX-2000N) and MMX Fire Alarm panels Power Consumption Amps (24VDC) Stand by 30 mA Alarm 30 mA DSPL-420DS 14 Line by 20 Character Backlit LCD Display Canada THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND 25 Interchange Way Vaughan, ON L4K 5W3 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 ��� For complete and accurate technical information relating to performance, U.S.A. installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER ;)*) Rev. 1 FOUR INDICATING CIRCUIT MODULE SGM-1004A General The SGM-1004A Module provides the FA-1000 or FX-2000 Series Fire Alarm Control panels with up to 4 Class A or B (Style Z or Y) Indicating Circuits. Applications The SGM-1004A provides up to four indicating circuits each rated at 1.7 Amps to signal devices such as strobes, bells, horns, etc. Each of the indicating circuits can be configured as non- silenceable (steady) or silenceable. In addition each circuit comes with an individual trouble indicator. All circuits are power limited for use with limited energy cable. The SGM-1004A is jumper selectable for individual circuit signal silence. In addition it has terminals for a bell cut relay. Features • Four Class A/B (Style Z/Y) Indicating Circuits • Each Indicating Circuit is rated at 1.7 Amps • Each Indicating Circuit can be configured as Non-Silenceable (Steady) or Silenceable • Outputs resound on subsequent alarm • LEDs (Amber) provided for indication of Indicating Circuit trouble • Programable to any input circuit • All circuits are power limited for use with limited energy cable • Removable terminal blocks for ease of wiring and servicing • Extensive transient protection on all circuits Installation The SGM-1004A consists of a PC board which mounts at the bottom of the chassis. The PC board is connected via cables to the board on the main chassis. Space is provided on the dress panel allowing the application of slide -in labels for indicating zone description. Labels are provided with each chassis Removable terminal blocks are provided for easy connection of field wiring and servicing. T� v c MEA ER '� approved S7010 S7010 7135-1477:106 313-97-E CATALOG NUMBER 5623 NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Typical Wiring Diagram IND1+ (Y/Z) INDICATION CIRCUIT 1 IND1+ (Z) (POWER SUPERVISED INDICATING CIRCUIT #1 STYLE Y LIMITED) WIRING IND1- (Z) � ND1- (Y2) IND2+(Y2) INDICATION CIRCUIT 2 IND2+ (Z) (POWER SUPERVISED INDICATING CIRCUIT #2 STYLE Z LIMITED) WIRING IND2- (Z) ND2- (Y/ ) IND3+ (Y/Z) INDICATION CIRCUIT 3 IND3+ (Z) (POWER SUPERVISED INDICATING CIRCUIT #3 STYLE Y LIMITED) WIRING IND3- (Z) IND3-(Y2) a--F IND4+ (Y2) INDICATION CIRCUIT 4 IND4+ (Z) (POWER SUPERVISED INDICATING CIRCUIT #4 STYLE Z LIMITED) WIRING IND4- (Z) IND4-(Y/Z) NOTES:ALL POWER LIMITED CIRCUITS MUST USE TYPE FPL, FPLR, OR FPLP POWER LIMITED CABLE. SGM-1004(A) INDICATING CIRCUITS ARE FULLY SUPERVISED AND RATED FOR 24 VDC UNFILTERED 1.70AMP MAX. THEY MUST BE WIRED AS SHOWN IN THE WIRING TABLES. LEGEND: SEE APPENDIX FOR COMPATIBLE DEVICES. l� BELL, HORN, OR STROBE r-I 3.9K 112W ELF LISTED S5434 ILIJ� MODEL MP-300 MANUFACTURED BY MIRCOM Technical Specifications OutputVoltage...................................................................................................................................... 24 VDC Unfiltered StandbyCurrent....................................................................................................................................................... 35 mA AlarmCurrent (unloaded)...................................................................................................................................... 150 mA Output Current per Zone - Power Limited............................................................................................................ 1.7 Amp End of Line Resistor......................................................................................................................... 3.91K ohm ±5%, 1/2 W NOT TO BE USED FOR INSTALLATION PURPOSES. 1411111, M i r c o m � Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com ISO 9001:2008 REGISTERED CAT.5623 Re, 5 QUAD LOOP ADDER MOTHER & DAUGHTER BOARD ALCN-960D ALCN-960MISO Description The ALCN-960MISO Quad Loop Adder mother board and the ALCN-960D daughter board are components of the FIeX-Net system that allows MIX-4000 series devices to be added to the project. The ALCN-960MISO/ALCN-960D connect on the internal bus and mount within the main panel enclosure. The SLCs may be configured for Class A or Class B wiring without the need for any additional modules Power is provided by the FIeX-Net main board Ordering Information Features ALCN-960MISO / ALCN-960D • ALCN-960MISO allows for two (2) SLCs ofMIX-4000 series devices to be connected to the FIeX-Net panel. • ALCN-960D can be connected to ALCN-960MISOto add an additional two (2) SLCs using only one(1)internal bus address. • Any combination of MIX-4000 series devices upto 240 can be connected on a single SLC. • Up to seven (7) ALCN-960MISO and seven (7) ALCN- 960D can connected on a FIeX-Net panel. Notes • All circuits are power limited and must use type FPL, FPLR, or FPLP power limited cable. • For more information, refer to wiring instructions inthe Network Fire Alarm Manual LT-894. Wiringis identical to that provided for ALCN-792M /ALCN-792MISO and ALCN-792D. Electrical Ratings ALCN-960MISO with ALCN-960D Power 24 VDC, 400mA MAX, 10kHz frequency MAX loop resistance 40 ohms Current Consumption: Standby: 200 mA Alarm: 213 mA & @ sw sue.=�,� Rvi 7165-1477:0111 Canada THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND 25 Interchange Way Vaughan, ON L4K 5W3 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 ��� For complete and accurate technical information relating to performance, U.S.A. installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER 9524 Rev 0 EIGHT RELAY CIRCUIT MODULE ��FclfcFcci=c>c ® § I i f Description The RM-1008A Eight Relay Circuit Module provides eight programable Form C relays. Each relay is rated for 28 VDC @ 1 Amp max. The RM1008A Relay Adder Module comes with removeable terminal blocks for easy wiring and servicing. The module connects via cable to the board on the main or expander chassis. The RM-1008A also mounts in the FX-2000 main and expander chassis. Ordering Information RM-1008A I Eight Relay Circuit Module RM-1008A Features • Eight programable Form C relays • 28 VDC @ 1 Amp max. per relay • Removeable terminal blocks • Mounts in the FX-2000 main and expander chassis Power Consumption Normal Operation Voltage AMps Standby Current 25 mA Alarm Current 150 mA Canada THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND 25 Interchange Way Vaughan, ON L4K 5W3 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 ��� For complete and accurate technical information relating to performance, U.S.A. installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER 5336 Rev. 0 PROGRAMMABLE INPUT SWITCHES MODULE Description The IPS-2424DS Programmable Input Switches Module, mounts into a series of enclosures as part of the fire alarm system. This adder module provides 24 programmable switches, 24 bi-coloured (red/amber) LEDs for fire alarm zone annunciation and 24 amber trouble LEDs. Compatible with FX-2000, FIeX-NetTM (FX-2000N) and MMX Fire Alarm panels. The bi-colored Led will flash red to indicate an alarm or it will flash amber to indicate that a supervisory alarm will be processed when the switch is returned to normal (unbypassed) position. Ordering Information IPS-2424DS 124 Programmable Input Switches Module Features IPS-2424DS • Provides 24 programmable switches • 24 bi-coloured (red/amber) LEDs for fire zone annunciation • 24 Amber Trouble LEDs • Programmable for Zoned/Group/Device bypass • Connects to to the main panel or RAX-LCD, RAXN-LCD, or RAXN-LCDG • Compatible with FX-2000 & FleXNet- (FX2000N and MMX Fire Alarm panels panels Cable Connections Ribbon Cable connects here on IPS-2424DS and goes to the next display module Ribbon IN. 0 O RIBBON OUT 0 RIBBON OUT Ribbon Cable is permanently attached here and connects to previous Ribbon OUT connector. RIBBON IN O (D RIBBON IN O Power Consumption Voltage 24VDC Standby Current 10 mA Alarm Current 22 mA Canada �THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND 25Interchange Way Vaughan, ON L4K 5W3 ('EMS' NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 UWE �!F'"� - For complete and accurate technical information relating to performance, U.S.A. Intertek installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305 contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER 5334 Rev. 0 DIGITAL ALARM COMMUNICATOR/DIALER MODULE Description The UDACT-300A Digital Alarm Communicator Transmitter/ Dialer Module allows Mircom's FA-1000, FX-2000 or FIeX-Net Series Fire Alarm Control Panels to transmit Alarm, Supervisory and Trouble information on two telephone lines to a monitoring facility. The UDACT-300A is powered by the host fire alarm control panel and communicates with the fire alarm control panel via an RS-485 data link. The Digital Communicator can be programmed for dual line operation and uses the Security Industry Association (SIA) and Ademco Contact ID reporting protocols. The UDACT-300A can be configured locally via the on -board keypad and the CFG-300 Configuration Tool or with a UIMA programming tool and a computer with an available serial or USB port. In addition the UDACT-300A can be remotely configured using a personal computer with a modem. The UDACT-300A can be configured for either DACT or UDACT operation. In DACT mode the Digital Communicator reports common alarm, trouble and supervisory information. In UDACT mode the Digital Communicator reports point specific information. In addition the UDACT-300A is equpped with the ZDACT feature that allows for input circuits on the FX-2000 or FIeX-Net panel to be grouped into software zones for the purpose of reporting to a central monitoring station. Features U DACT-300A • Communicates with Mircom's FA-1000, FX-2000 or FIeX- Net Series fire alarm control panels via an RS-485 data link • Programmed to use the Ademco Contact ID and SIA-DCS reporting protocols • Can be configured for DACT or UDACT mode of operation • DACT mode transmits a common Alarm, Supervisory, Waterflow and Trouble information • UDACT mode transmits point -specific Alarm, Supervisory, Waterflow, and Trouble information • ZDACT feature allows for input circuits on the FX-2000 or FIeX-Net panel to be grouped into software zones so that the UDACT-300A will report any individual event as a group event • Reports either the circuit number or the combination of loop number and address when used with the FX-2000 or FIeX-Net Series • Event number offset for output circuit numbers provides the ability for each circuit on an FX-2000 or FIeX-Net Series panel to have a unique circuit number transmitted to the monitoring station • Override feature allows for the device type to be changed from the standard input type on the FX-2000 or FIeX-Net Series panel to a pre -defined input type that is sent to the monitoring station • UDACT-300A has the ability of disconnecting the incoming and outgoing calls and capturing the line for transmission to the Digital Alarm Communicator Receiver (DACR) • Onsite or remote programming • Onsite configurable with the on -board keypad and the CFG- 300 Configuration Tool or using the UIMA Programming Tool and a computer with an available serial or USB port • Remotely configurable via a Personal Computer with a modem (Configuration is passcode protected) • Provides telephone line monitoring and reports status via LED indication on -board • Provides event logs of 500 entries each to save events from local dialer or remote fire alarm panel • Logs can be reviewed locally with the CFG-300 Configuration Tool or remotely via modem • Continuously supervises the status of each of two connected telephone lines at approximately one minute intervals • Mounts in a dedicated location in the FA-1000, FX-2000 or FIeX-Net Series main chassis U sO MEA approved S7010 S7010 7165-1477:111 313-97-E CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. 5345 UDACT-300A Connection Diagram CFG-300 Configuration Tool The CFG-300 Configuration Tool is required for onsite programming of the UDACT-300A. The CFG-300 plugs into the UDACT-300A to provide a two line by 20 character LCD display. The CFG-300 tool is used for configuration purposes only and not for normal operation. Current Consumption Standby 40 mA Alarm 60 mA UDACT-300A Wiring Diagram imimieimimimimim i sIRES CA CC L1 1-1 klywe 1 2 B 0-yL112Q TO UIMA P2 P1 CFG-300 Configuration Tool SYSTEM NORMAL Ribbon cable 18:01 MON 2003-04-05 connects to Mircom FA-1000 or FX-2000 Series , ° .a fire alarm control U18 1C �' 0 0 � 0 panel 1 ®I LAMPTES ° URI 0 0 o a 1W2 000aW1 O a IQ O Mounting holes (Four) ,000a, 1 0 0 4 TIP 2 3 7 s RING 8 0 0 5 Public switch Telephone company R331X wiring TIP RING Z premise telephone 3 t w IF permitted m 0: Line 2 is Wired as shown for Line 1 T R I T RI T R I T RI RES C.O. RES C.O. LINE-1 LINE-2 UDACT-300A 110 F4-tr e-n Fill forlifil IYI ITrerf 11111k, M G C Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 Telephone: (905) 660-4655 Toll Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. 042`0For complete and accurate technical information relating to �I performance, installation, testing and certification, refer to technical T.%+ literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 5345 Rev. 0 REMOTE MULTIPLEX ANNUNCIATORS MEE == ------ ------ ------ - - - - - - RA-1000 SERIES WEEMMOME ------ ------ EME ------ ------ ------ ------ ------ --=omom VMM BB-1001 D Description BB-1003D Mircom's modular RA-1000 Series Remote Annunciators are multiplex annunciator panels that provide a large capacity of annunciation with the Mircom Fire Alarm Control Panels. The RA-1000 Series is comprised of three chassis models. The RAM-1032TZDS Main Annunciator Chassis consists of sealed membrane -like buttons and LED indicators. Complete with Common Control Features and Indicators, the RAM-1032TZDS Main Annunciator Chassis provides up to 32 points of annunciation and can be expanded with up to four RAX adder annunciator chassis modules. Defined via DIP switches, the RA-1000 Remote Annunciators are automatically configured to match the Fire Alarm Control Panel configuration. The RAX-1048TZDS Adder Annunciator Chassis has the same basic construction as the Main Annunciator Chassis and can provide up to 48 points of annunciation. It interconnects to either a RAM-1032TZDS Main Annunciator or a RAX-1048TZDS Adder Annunciator Chassis. Up to four RAX-1048TZDS Adder Annunciator Chassis' can be connected to one RAM-1032TZDS. The annunciators come standard with Bi-coloured LEDs to annunciate Alarm or Supervisory points. Each display point can be identified by the slide -in label that slides in beside the LED. The annunciator modules can mount into five various sized enclosures. Features BB-1002D H • Large capacity of annunciation • Provides annunciation through three annunciator chassis modules • Bi-coloured LEDs • Slide -in labels for each display point • Surface mount to standard gang outlet boxes • Sealed membrane -like buttons and LED indicators • Local Buzzer, Silence and Lamp Test switches • LEDs for A.C. On, Common Trouble, Remote Failure, Aux. Disconnect, Acknowledge, General Alarm, Signal Silence and Test/Configuration Mode • Controls for System Reset, Lamp Test, Fire Drill, Aux. Disconnect, Buzzer Silence, Signal Silence, General Alarm and Acknowledge • Each annunciation point is automatically selected for either Alarm (Red) or Supervisory (Amber) to match the Fire Alarm Control Panel configuration • Five sizes of enclosures • Enclosures are available in a white colour for the Canadian market and a red exterior for the U.S. and International markets M EA approved CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. 5505 1313-1001 D Semi -Flush Enclosure The BB-1001 D comes complete with a backbox, door and hinge. The enclosure door comes with a Lexan window, two keys and a durable lock. The door comes hinged to the left side of the box. The box is capable of handling one RAM-1032TZDS, RAXN-LCD, and RAXN-LCDG Annunciators. BB-1002D Semi -Flush Enclosure The BB-1002D comes complete with a backbox, door and hinge. The enclosure door comes with Lexan windows, two keys and a durable lock. The door comes hinged to the left side of the box. The enclosure is capable of handling one RAM-1032TZDS, RAXN-LCD, RAXN-LCDG, Main Annunciator Chassis and one RAX-1048TZDS Adder Annunciator Chassis. BB-1003D Semi -Flush Enclosure The BB-1003D comes complete with a backbox, door and hinge. The enclosure door comes with Lexan windows, two keys and a durable lock. The door comes hinged to the left side of the box. The enclosure is capable of handling one RAM-1032TZDS, RAXN-LCD, RAXN-LCDG, Main Annunciator Chassis and two RAX-1048TZDS Adder Annunciator Chassis. NOTE: All BB-1000D Series Enclosures are available in a white colour for the Canadian market and a red exterior for the U.S. and International markets. Dimensions BB-1001 D Enclosure: 9"H x 12.75"W x 1.85"D BB-1002D Enclosure: 18"H x 12.75"W x 1.85"D BB-1003D Enclosure: 26.4"H x 12.75"W x 1.85"D 0101 new ft sigammi sm E3 BB-1001 D e a O 11 e ■ o o e ■ 0 o 0 e Y Y O O o e ■ N ■ o 0 e o 0 0 e o■ k o 0 N ■ ■ ■ m am M M ® a m m m m ® ® 0111111 new M M !M M M M = ®� 11111101 BB-1002D � o ■ ■ I!1aa ■0 a o o 0 e m 1 N_ �CIMCINMCIMCIMCIM �C=CIMCIIMC=C= �CIMCIMC]IOCIMCBM �C=CIMC=CIMCIIN �CMCIMC=CIMCIM ffl=C]MCIMCIIMCIIMCIM �cmmcllmclm(llmclm C!=C='7clmc�CIM ® was M ® M M BB-1003D NOT TO BE USED FOR INSTALLATION PURPOSES. CAT. 5505 ``����`/ n/�' THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND Page 2 of 3 ,/ Mircom NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. r _ _ M i 0 E 0 Liman 0 am W6 EMCM Man RAM-1032TZDS The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM- 1032TZDS has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. RAX-1048TZDS The RAM-1032TZDS Main Remote LED Annunciator provides common annunciator functions and 32 points of LED annunciation. The RAM- 1032TZDS has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. Typical Remote Annunciator Wiring Diagram RAXN-LCD The RAXN-LCD Remote Network LCD Annunciator is equipped with a large 4-line x 20-character back -lit alphanumeric LCD display that provides an exact replica of the main FleXNet fire alarm control panel display. 1 Twisted Shielded Pair for Communications 1 Untwisted Unshielded Pair for 24 VDC Power RAXN-LCDG The RAXN-LCDG Remote Network Graphic LCD Annunciator is equipped with a 24 line x 40 character back- lit graphical LCD display that is used to display 9 events per page. Each event is displayed over 2 lines with 40 characters per line allowing emergency information to be displayed in easy to read format. The RS-485 wiring needs to be twisted shielded pair. The wire gauge may be 22 AWG up to 4000 ft., 20 AWG up to 6000 feet or 18 AWG up to 8000 ft. 0 RA-1000 Series RA-1000 Series Remote Multiplex Annunciator Remote Multiplex Annunciator (BB-1001 Enclosure) (BB-1001 Enclosure) Fire Alarm Control Unit NOTE: Annunciator wiring must be as shown. Star type or `T' tap connections are not allowed. The RA-1000 Series Remote Annunciators must be wired in a loop configuration. Ordering Information Model BB-1001 D* Annunciator backbox with keylock door (Houses 1 module) BB-1002D* Annunciator backbox with keylock door (Houses 2 modules) BB-1003D* Annunciator backbox with keylock door (Houses 3 modules) RAM-1032TZDS 32 Zone Bi-Colored LED Annunciator RAX-1048TZCS 48 Zone Bi-Colored LED Annunciator RAXN-LCD Remote Network LCD Annunciator RAXN-LCDG Remote Network Graphic LCD Annunciator 'For BB-1000D series on red versions, add the suffix R. Alki, Mircom° Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. 042`0For complete and accurate technical information relating to �I performance, installation, testing and certification, refer to technical T.%+ literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 5505 Rev. 12 NETWORK REMOTE GRAPHIC ANNUNCIATOR Description The RAXN-4000LCDG provides an exact replica of the main FIeX-NetTM or MMXTm Fire Alarm Panel display (except with a 9-event 24-line graphical display) at a remote location. It is equipped with a simple menu system complete with a directional keypad and switches for Enter, Menu, Cancel and Info. The RAXN-4000LCDG supports up to a maximum of 41 frames, 13 for the first header P5, and 14 frames per headers P6 and P7. A "frame" is a measure of display capacity. Each display module has its own frame measure. The displays available are RAX-1048TZDS (3 frames), IPS-2424DS (2 frames), IPS-4848DS (4 frames), QAZT-5302DS (2 frames), QAZT-5348DS (4 frames), AGD-048 (1 frame), and FDX-008W/ KI (1 frame). There are five types of enclosures available: the BB-1000 Series which can take 1,2,3,8 and 12 chassis respectively. The RAXN-4000LCDG may also be mounted in the BB-5008 and the BB-5014 backboxes as part of a central location or node Ordering Information Features RAXN-4000LCDG • Provides an exact replica of the main FIeX-Net TM or MMXTM Fire Alarm Panel display • Large 9-event x 24-line graphical display • Simple menu system with a directional keypad and switches for Enter, Menu, Cancel and Info. • The RAXN-4000LCDG may be mounted in the BB-1000 Series and BB-5000 Series backboxes. Power Consumption RAXN-4000LCDG I Network Remote Graphic Annunciator Normal Operation Voltage AMPS Stand by 117 mA Alarm 150 mA Canada THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND 25 Interchange Way Vaughan, ON L4K 5W3 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 ��� For complete and accurate technical information relating to performance, U.S.A. installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER 5352 Rev. 1 MASTER GRAPHIC DRIVER MODULE Description The MGD-32 is a Master Graphic Driver module that provides common control inputs for the common control switches. These include: System Reset, Signal Silence, Auxiliary Disconnect, Fire Drill, Lamp Test Acknowledge and General Alarm. Any of these switch inputs can be used and are supervised outputs for all of the support LEDs and common control switches. The MGD-32 can also drive up to 32 supervised outputs, the output points are proficient of driving LEDs or luminescent lamps. When using LEDs, a 6.8K 1/4W current limiting register is required. It can support the AGD-048 (Adder Graphic Driver Module). Maximum of 8 remote Annunciator modules comprised of the RAM-1032 LED Annunciator and MGD-32 Graphic Driver Modules per system. Mounts in a graphic annunciator wall box or in the BB-5000 enclosures. An external power supply may be required for luminescent lamps and lamp test. MGD-32 Features • Master Graphic Driver Module c/w Fire Alarm Common Control Switch Inputs and 32 Supervised Outputs • MGD-32 has no button or LEDs on the board. • MGD-32 and the AGD-048 are combined with a GRAPHIC DISPLAYto make a graphic annunciator • Use with FX-350, FA-1000, FX-2000 and FX-3500 series fire alarm control panels Specifications • 24V DC nominal, range 20 to 39 V DC • Annunciation of up to 32 Points. • Expandable by using up to four AGD-048 Adder Modules. • Standby: 35 mA, Alarm: 1.6A Max • Each Master Graphic Driver MGD-32 needs to be assigned a unique, sequential "Address • This annunciator is intended for indoor use only. 15 r�Nc APPROVED THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. CATALOG NUMBER 5949 Ordering Information Model Description MGD-32 Master Graphic Driver Module c/w Fire Alarm Common Control Switch Inputs and 32 Supervised Outputs AGD-048 Adder Graphic Driver Module c/w 48 Supervised Outputs THIS INFORMATION IS FOR MARKETING PURPOSES 1411111,M i ONLYAND NOT INTENDED TO DESCRIBE THE PRODUCTS _ rcom TECHNICALLY. Canada U.S.A. For complete and accurate technical information relating 25 Interchange Way 4575 Witmer Industrial Estates �m� to performance, installation, testing and certification, refer Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 A�0 ` to technical literature. This document contains intellectual Telephone: 905 660-4655 Toll Free: 888 660-4655 p ( ) ( ) 11".^ .M property of Mircom. The information is subject to change by Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Intertek Mircom without notice. Mircom does not represent or warrant correctness or completeness. Website: www.mircom.com Email: mail@mircom.com CAT. 5949 Rev 0 SMOSOM88 GRAPHIC ANNUNCIATOR WITH LCD FULL COLOR MATRIX ANNUNCIATOR FIR .°wSSIONE-1 RSC-GR-GP4 FULL COLOR GRAPHIC ANNUNCIATOR (RSF-L-GP3 w/ stainless steel door) r-- PIN ®® ®©► d ­4 GRAPHIC ANNUNCIATORS MATERIAL Boxes: #16 Gauge Steel with Black Textured Finish (Standard) Door: #16 Gauge Steel with Black Textured Finish (Standard), or #16 Gauge Stainless Steel with #4 Horizontal Brush (Upon Request) Hinge: Concealed Stainless Steel located on the left side Fastener: #2171 Key Change Lock BACKBOX DEPTH Semi -Flush: 3.50" Surface: 4.75" STANDARD - Constructed of cold rolled ADDITIONAL steel w/ fully welded and FEATURES grounded seams - Durable powder textured coat with baked -on finish RSE-GR-GP3 RSE-GR-GP3 DETAIL (w/ backlighted symbols) (backlighted symbol illuminated) KIRKLAND PANELS ARE UL (UUKL), CSFM, OSHPD @/UUKL & HAVE AN OSHPD SEISMIC CERTIFICATION. 011eof5tatew1eHea1� Fiaom ng aaa o­ioomeac - Standard material is UL94VO flame retardant grade lexan, but anodized aluminum and stainless steel also available - Full -color graphics at no additional charge. - Indoor or outdoor mount. See Exterior Annunciator specifications if your application requires mounting outdoors. - Wire directly to fire alarm lamp driver modules or hardwire to terminals. GRAPHIC ANNUNCIATORS AN INTRODUCTION TO KIRKLAND'S ANNUNCIATORS A Graphic Annunciator is fire alarm equipment depicting the fire alarm device location within the floor layout. By providing pre- cise information and illustrating the exact location of the alarm, a Graphic Annunciator increases a Fireman's response time be- cause the Fireman does not have to scroll through touchscreens to find the device that has gone into alarm. The Graphic Annunciator design can vary according to code, the AHJ, and/or the owner of the facility. In some cases, all devices are shown with LEDs. In other cases, the floorplan will be divided into zones, with a zone LED, and corresponding device type LEDs. Kirkland specializes in Fire Alarm Graphic Design and Graphic Display methods, that allow for a clear, concise illustration of the layout. We can incorporate photographs/rendered images, logos, etc. into the display graphics and offer unlimited colors at no additional charge. Our product design provides easy and inex- pensive modifications when changes are required in the future. With our unique manufacturing and printing process, a Kirkland Graphic Annunciator can range from a simple Matrix (Ladder) type display to a full -color, high resolution, digitally printed display never before seen in the industry. The Kirkland Graphic Annunciator is available in a number of standard sizes. Larger panels are our specialty! SPECIFICATIONS Model Visible Display width height Semi -Flush width height Surface width height Overall width height BGRA-GR 4.35 8.85 7.50 12.75 8.85 14.25 9.30 14.50 BGRB-GR 8.85 8.60 12.00 12.75 13.35 14.25 13.80 14.50 RSB-GR 7.80 9.80 1 12.00 14.25 13.50 15.75 1 14.00 16.00 RSC-GR 15.80 12.80 20.00 17.25 21.50 18.75 22.00 19.00 RSC-L-GR 12.80 15.80 17.25 20.00 18.75 21.50 19.25 21.75 HINGED ON LONG SIDE RSD-GR 17.80 17.80 22.00 22.25 23.50 23.75 24.00 24.00 RSE-GR 23.80 17.80 28.00 22.25 29.50 23.75 30.00 24.00 RSE-L-GR 17.80 23.80 22.25 28.00 23.75 29.50 1 24.25 29.75 HINGED ON LONG SIDE RSF-GR 35.60 23.60 1 39.88 28.00 41.18 29.38 41.63 30.00 RSF-L-G R 23.60 35.60 28.00 39.88 29.38 41.18 30.00 41.63 HINGED ON LONG SIDE RSG-GR 46.60 34.60 50.80 39.00 52.20 40.40 52.75 41.00 RSG-L-GR 34.60 46.60 39.00 50.80 40.40 52.20 41.00 52.75 HINGED ON LONG SIDE RSH-GR 73.00 34.00 N/A N/A 79.00 40.00 79.50 40.50 FIRE ALARM ADDRESSABLE MANUAL PULL STATIONS MPS-800MP(U) SERIES �»-1 50-> -6 _0< � M•�wr� �Y �� I MPS-810MP(U) MPS-802MP 1 Stage 2 Stage Description Mircom's MPS-800MP(U) Series Fire Alarm Manual Pull Stations provide manual fire alarm activation. The new MPS-800 Series uses raised symbols and icons instead of printed text that makes them universally recognized. Features • Completely made of LEXAN material • Closed -fist operation (ADA—Americans with Disability Act) • No printed text on the devices, symbols and icons are used instead • Symbols are raised to be easily recognized by touch • Compatible with FX-400 Series and Flex -Net FX-4000 Fire Alarm Panels • Easy installation • Accessible from the front for wiring while mounted • Mounts on a single gang backbox • Temperature range from 0°C to 490C / 32°F to 120OF • Device comes with a reset key • Indoor use only • Alarm LED is viewable from the front - Useful for trouble shooting Operation Activating the Alarm • Push in the push bar • Pull down the pull handle These addressable pull stations are available as single or two stage dual action devices. Compatible with FX-400 Series and Activating the stage two alarm (MPS-802MP and Flex -Net FX-4000 Fire Alarm Panels. MPS-822MP) The MPS-800MP(U) manual stations are constructed of high quality polycarbonate resin thermoplastic "LEXAN" that supports high temperatures without deforming. The MPS-800MP(U) addressable pull stations are accessible from the front forwiring while mounted making it easy to install. These pull stations can be mounted on a single gang backbox and the mounting holes permit easy alignment to the wall. The suffix "U" indicates USA version. All manual fire alarm stations shall be installed as per the specific requirements outlined in the UL/ULC codes, as well as all other applicable national or local codes. Addressing is done using the MIX-4090 Device Programmer. For setting the address on this device, disconnect it from the loop, or ensure that the loop to which is connected is both disconnected from the panel and shorted across the SCL+ and SLC- inputs at the device. Failing to take either of these steps may change the address programming of previously configured sensors on the loop. NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. • Insert the stage two key into the stage two keyhole, and then turn the key. • The stage two alarm activates immediately. Resetting the manual station • Insert the key into the reset keyhole and turn it. • Pull the cover open. The switch is now reset. • Close and lock the stations with the reset key. • Reset the Fire Alarm Control Panel to reset the alarm Note: Resetting the station does not cancel the alarm at the panel @@X CATALOG NUMBER 5964 Specifications Dimensions Manual Pull Station: 5'/2' H x 4 1/8" W x 1 3/8" D Nominal Operating Voltage: 15-30 VDC Maximum alarm Current: 3.3 mA Standby current: 2 mA Electrical rating for MPS-802MP Maglok terminal: 1 Amp @ 30 VDC Wiring Diagram Mounting Diagram • Flush mount indoor: Single -gang electrical box • Surface mount indoor: BB-800 backbox FROM PREVIOUS STATION ao ❑o❑�❑� 00 ��❑o❑��❑o 000 ❑❑ �ODa� ❑ ®� MOUNTING a® O HOLES a® ® ❑ NC C NO + — TO NEXT STATION OR 00® �0❑ TO MAGLOCK (MPS-822MP) LEAVE IT EMPTY Ordering Information Model MPS-81 OMP MP 1 Stage Addressable Double Action Pull Station, ULC MPS-81 OMPU MP 1 Stage Addressable Double Action Pull Station, UL MPS-802MP MP 2 Stage Addressable Pull Station, ULC MPS-822MP MP Maglock 2 Stage Double Action Pull Station, ULC MIX-4090 4000 Series Address Programmer BB-800 Surface Backbox for 800 Series Manual Station %lki, Mircom- THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND ����J NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Canada `�" " '"' For complete and accurate technical information relating to performance, installation, testing 25 Interchange Way Vaughan, ON L4K 5W3 Intertek and certification, refer to technical literature. This document contains intellectual property of Telephone: (905) 660 4655 Fax: (905) 660-4113 Mircom. The information is subject to change by Mircom without notice. Mircom does not represent or warrant correctness or completeness. All rights reserved. All other trademarks U.S.A. and registered trademarks are properties of their respective owners. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 CAT. 5964 www.mircom.com Rev. 1 PHOTOELECTRIC SMOKE SENSORS MIX-40101 MIX-4010-ISO Features • Any combination of MIX-4000 series devices up to 240 can be connected on a single SLC. • Different LED colors for Alarms and Troubles. /', • Detection of smoke using advanced software algorithms. • Protection against nuisance alarms caused by dust, \ insects or other debris. • Multiple sensitivity settings. • Compatible with the full series of MIX-4000 input and control modules. • The device can be secured by a unique Anti -Tamper feature. • Address is set with the hand-held device programmer MIX-4010 / MIX-4010-ISO (MIX-4090) • MODEL OPTION - Built -In short-circuit isolator (MIX-401 0-I SO) Description The MIX-4010/MIX-4010-ISO smoke detector is a hardwired sensor that continuously monitors the environment to provide early warning of a fire condition and communicates with the panel using a fully digital protocol. The MIX-4010/MIX-4010-ISO works with an MGC compatible control panel supporting high rates of information exchange with reliable and secure bi-directional communication. The detector is addressed and programmed using the MIX-4090 hand-held device. Addresses can be selected from a range of 1 -240. This detector ships with a dust cover to protect the device during installation and prior to commissioning. Two tri-color LEDs on the device provide 360 degrees of status visibility. A remote LED indicator can be wired directly to the sensor. NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Benefits • Open style mounting bases offer easy wiring and low pressure locking. • 4" or 6" base options available. • Remote output can be controlled by the panel. • MIX-4010-ISO is equipped with a bi-directional short- circuit isolator to protect against wiring faults and loop failure. • Low standby current. • Base has detachable tab for labeling device address. • Leverages interrupts to quickly report alarm conditions to fire alarm control panels. • Magnet test option helps with commissioning and maintenance. 15 rrq, CATALOG NUMBER 9501 Specifications Normal Operating Voltage 15 to 30VDC Maximum Alarm Current 3.2mA (LED on) Standby Current 160pA Temperature Range 320F to 1001F (0°C to 37.8°C) Humidity 10% to 93% Non -condensing Wiring range on terminals 22 to 12 AWG Diameter 4.25" Height 1.75" Ordering Information Detector LED colors RED (Steady on) ALARM condition GREEN (Flash) NORMAL condition AMBER (Steady on) FAULT condition Sensitivity Level Typical Note LEVEL 1 1.75%/FEET Most Sensitive level LEVEL 2 2.25%/FEET Sensitivity level LEVEL 3 2.75%/FEET Sensitivity level LEVEL 4 3.25%/FEET Least Sensitive Level Model MIX-4010 Photoelectric Smoke Detector (Non -Isolated) MIX-4010-ISO Photoelectric Smoke Detector (with short-circuit isolator) MIX-4020 Multi-Criteria/Multi-Sensor (Non -Isolated) MIX-4020-ISO Multi-Criteria/Multi-Sensor (with built-in short circuit isolator) MIX-4030 Heat Detector (Non -Isolated) MIX-4030-ISO Heat Detector (with built-in short circuit isolator) MIX-4090 MIX-4000 Series Addressable Device Programmer MIX-4001 6" Detector Base MIX-4002 4" Detector Base Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. U.S.A. j 4575 Witmer Industrial Estates Off��� For complete and accurate technical information relating to Niagara Falls, NY 14305 performance, installation, testing and certification, refer to technical Toll Free: (888) 660-4655 T. literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Fax Toll Free: (888) 660-4113 Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 9501 Rev. 3 TRI-MODE HEAT DETECTOR MIX-4030 / MIX-4030-ISO Description The MIX-4030/MIX-4030-ISO detector is a hardwired sensor that continuously monitors the environmental temperature to report high heat conditions and communicates with the panel using a fully digital protocol. An alarm will be reported when the sampled temperature exceeds 135°F (57°C) or 175°F (79°C) depending on the chosen mode of operation. Excessive temperature rises can also be reported if the detector is configured for rate - of -rise operation. The MIX-4030/MIX-4030-ISO works with an MGC compatible control panel supporting high rates of information exchange with reliable and secure bi- directional communication. The detector is addressed and programmed using the MIX-4090 hand-held device. Addresses can be selected from a range of 1 -240. This detector ships with a dust cover to protect the device during installation and prior to commissioning. Two tri-color LEDs on the device provide 360 degrees of status visibility. A remote LED indicator can be wired directly to the sensor. NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. MIX-40301 MIX-4030-ISO Features • Any combination of MIX-4000 series devices up to 240 can be connected on a single SLC. • Different LED colors for Alarms and Troubles • Three operational modes of heat detection. • Compatible with the full series of MIX-4000 input and control modules. • The device can be secured by a unique Anti- Tamper feature. • The address is set with the hand-held device programmer (MIX-4090) • MODEL OPTION - Built-in short-circuit isolator (MIX 4030- ISO) • Operating Modes - Rate of rise heat detection (135°F/57°C) - Fixed heat detection (135°F/570C) - Fixed heat detection (175°F/790C) Benefits • Open style mounting bases offer easy wiring and low pressure locking • 4" or 6" base options available • Remote output can be controlled by the panel • MIX-4030-ISO is equipped with a bi-directional short- circuit isolator to protect against wiring faults and loop failure. • Low standby current. • Base has detachable tab for labeling device address. • Leverages interrupts to quickly report alarm conditions to fire alarm control panels. • Magnet test option helps with commissioning and maintenance. l CATALOG NUMBER 9503 Technical Specifications Normal Operating Voltage 15 to 30VDC Maximum Alarm Current 3.2mA (LED on) Standby Current 160pA Temperature Range 320F to 1001F (0°C to 37.8°C) Humidity 10% to 93% Non -condensing Wiring range on terminals 22 to 12 AWG Diameter 4.25" Height 1.75" Detector LED colors RED (Steady on) ALARM condition 135°F (57°C) GREEN (Flash) NORMAL condition 175°F (79°C) AMBER (Steady on) FAULT condition 135°F (57°C) rate of rise Ordering Information Model MIX-4010 Photoelectric Smoke Detector (Non -Isolated) MIX-4010-ISO Photoelectric Smoke Detector (with short-circuit isolator) MIX-4020 Multi-Criteria/Multi-Sensor (Non -Isolated) MIX-4020-ISO Multi-Criteria/Multi-Sensor (with built-in short circuit isolator) MIX-4030 Heat Detector (Non -Isolated) MIX-4030-ISO Heat Detector (with built-in short circuit isolator) MIX-4090 M IX-4000 Addressable Device Programmer MIX-4001 6" Detector Base MIX-4002 4" Detector Base Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. U.S.A. j 4575 Witmer Industrial Estates Off��� For complete and accurate technical information relating to Niagara Falls, NY 14305 performance, installation, testing and certification, refer to technical Toll Free: (888) 660-4655 T. literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Fax Toll Free: (888) 660-4113 Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 9503 Rev. 3 4000 SERIES DETECTOR BASES MIX-4001 / MIX-4002 Description The MIX-4001 and MIX-4002 mounting bases are used to interface series 4000 detectors to the SLC line and remote devices. The low profile base can be wired and secured to a back -box during building construction, allowing the detector to be installed later, when premises become free of dust and other contaminants. Ordering Information MIX-4001 1 MIX-4002 Features • Sleek low profile design • Ceiling or wall mountable • 4" or 6" options • The base provides a device Anti -Tamper feature Benefits • Open style mounting bases offer easy wiring and low pressure docking • Save time with multiple mounting options • A breakable flat tab in the centre of the base can be cut and inserted in the base outer edge, then a label can can be used to identify the device Technical Specifications Wiring Range on all terminals 22 to 12 AWG Diameter 6" (MIX-4001) 4"(MIX-4002) Height 0.625" Height Canada THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND 25 Interchange Way Vaughan, ON L4K 5W3 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 ��� For complete and accurate technical information relating to performance, U.S.A. installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER 9505 Rev. 1 DUAL INPUT MODULE A-- no/�� om wa wt as LA MID r` • 1WAlINNRM001R! .�_ ,« ....._ FL—C. BARCOOE �mi+ems 1k Ouo .rr tCi 1 1 Description The MIX-4040 Dual Input Module is an intelligent addressable device designed to be used with a MGC compatible control panel, providing a high rate of exchanged information with fast and secure responses. The module can be used for alarm, supervisory, or monitor type applications. MIX-4040 Features • Any combination of MIX-4000 series devices up to 240 can be connected on a single SLC. • Mounts in a standard 4" square or double gang electrical back box. • Indicating LED provides module status Benefits • Fast, reliable contact monitoring. • Will automatically set inputs to single Class A or dual Class B according to the configuration sent by the fire alarm panel. • No EOL resistor required when input is in Class A operation. The MIX-4040 Dual Input module provides two (2)independent Monitors two (2) independent circuits in Class B using contact monitoring circuits only utilizing one(1) address on the one (1) module address SLC loop. The module supports one (1) Class A or two (2) Class B inputs. When configured for Class A operation, the module provides an internal EOL resistor. When configured for Class B operation, the module monitors two (2) independent input circuits using only one (1) module address. The module has a panel controlled LED indicator. The LED flashes during normal operation and stays ON steadily when the device is in alarm condition. The address of each module is set using the MIX-4090 programmer tool. For setting the address on this device, disconnect it from the loop, or ensure that the loop to which is connected is both disconnected from the panel and shorted across the SCL+ and SLC- inputs at the device. Failing to take either of these steps may change the address programming of previously configured sensors on the loop. CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. 9504 Technical Specifications Normal Operating Value 15 to 30 VDC Maximum Alarm Current 3.3mA (LED on) EOL Resistance 22K Ohms Maximum Input Wiring Resistance 150 Ohms Total Temperature Range 32°F to 120°F (0°C to 49°C) Humidity 10% to 93% Non -condensing Wiring Range on all terminals 22 to 12 AWG Dimensions 4.625"H x 4.25" W x 1.125" D Mounting Typically mounted on a standard 4" square box. Also compatible with double -gang electrical boxes or Mircom BB-400 surface mount box. Standby Current (2 Class B) 2mA Ordering Information Model MIX-4040 Dual Input Module MIX-4090 M IX-4000 Addressable Device Programmer MP-302 EOL on Mounting Plate BB-400 Surface Mount Electrical Box Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. U.S.A. j 4575 Witmer Industrial Estates Off__� For complete and accurate technical information relating to Niagara Falls, NY 14305 ��� performance, installation, testing and certification, refer to technical Toll Free: (888) 660-4655 T. literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Fax Toll Free: (888) 660-4113 Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 9504 Rev. 3 MINI DUAL INPUT MODULE MIX-4041 Features • Any combination of MIX-4000 series devices up to 240 can be connected on a single SLC • Fits in a single gang junction box I• Indicating LED provides module status Benefits • Fast, reliable contact monitoring. • Will automatically set inputs to single Class A or dual Class B according to the configuration sent by the fire alarm panel. • No EOL resistor required when input is in Class A operation. Description • Monitors two (2) independent circuits in Class B using one (1) module address. The MIX-4041 Mini Dual Input Monitor Module is an intelligent addressable device designed to be used with a MGC compatible control panel providing high rates of information exchange and fast and secure responses. Technical Specifications The MIX-4041 Mini Dual Input Monitor Module provides two (2) independent contact monitoring circuits only utilizing one (1) address on the SLC loop. The module supports one (1) Class A or two (2) Class B inputs. When configured for Class A operation, the module provides an internal EOL resistor. When configured for Class B operation, the module can monitor two (2) independent input circuits while using only one (1) module address. The module has a panel controlled LED indicator. The LED flashes during normal operation and stays ON steadily when the device is in alarm condition. The address of each module is set using the MIX-4090 programming tool. For setting the address on this device, disconnect it from the loop, or ensure that the loop to which is connected is both disconnected from the panel and shorted across the SCL+ and SLC- inputs at the device. Failing to take either of these steps may change the address programming of previously configured sensors on the loop. Ordering Information Normal Operating Value 15 to 30 VDC Maximum Alarm Current 3.3mA (LED on) EOL Resistance 22K Ohms Maximum Input Wiring Resistance 150 Ohms Total Temperature Range 32°F to 120°F (0°C to 49°C) Humidity 10% to 93% Non -condensing Dimensions 1.25" H x 2.75" W x 0.50" D Connections 6" pigtail wires Standby Current (2 Class B) 2mA ST)� sw Canada THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND 25 Interchange Way Vaughan, ON L4K 5W3 NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Telephone: (905) 660-4655 1 Fax: (905) 660-4113 For complete and accurate technical information relating to performance, U.S.A. installation, testing and certification, refer to technical literature. This document 4575 Witmer Industrial Estates Niagara Falls, NY 14305 ��� .M contains intellectual property of Mircom. The information is subject to change Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 Intertek by Mircom without notice. Mircom does not represent or warrant correctness or completeness. www.mircom.com CATALOG NUMBER 9506 Rev. 3 DUAL RELAY MODULE NO2QD M ono rowan � 0 09k Kn•r MOM$ NCY [11ARC6tiEJ C 1 NOt T',2WTWW® �� • ,may Description The MIX-4045 Dual Relay Module is an intelligent addressable device designed to be used with an MGC compatible control panel, providing high rates of information exchange and fast and secure responses. The MIX-4045 Dual Relay Module controls two independent circuits while using only one module address. The module provides two form C (SPDT) contacts rated at 2A @ 30VDC or 0.5A at 125VAC and the Fire panel can control each contact individually. Contacts are electrically isolated from the Fire alarm panel at all times. Refer to MIX-4046 if a supervised output is required. The contact position is verified by the module at all times. If a contact is not at the required position during standby or active conditions, a trouble will be reported by the panel. The module has a panel controlled LED indicator. The LED flashes during normal operation and stays ON steadily when the device is in alarm condition. The address of each module is set using the MIX-4090 programmer tool. For setting the address on this device, disconnect it from the loop, or ensure that the loop to which is connected is both disconnected from the panel and shorted across the SCL+ and SLC- inputs at the device. Failing to take either of these steps may change the address programming of previously configured sensors on the loop. MIX-4045 Features • Any combination of MIX-4000 series devices up to 240 can be connected on a single SLC. • Mounts in a standard 4" square or double gang electrical back box. • Indicating LED provides module status. • Two individually controllable contacts per module. • Each contact provide access to normally closed and normally open sides. • Contact position is verified by the module. Stuck or inoperative contacts are reported as a trouble. Benefits • The SLC and externally powered connections are on opposite sides of the device for easy installation (no need to install an additional barrier). • Supports group activation capability for fast reaction time • Provides two (2) outputs using only one (1) module address lSTt� CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. • Technical Specifications Normal Operating Value 15 to 30 VDC Maximum Alarm Current 3.1 mA Standby Current 1.5 mA Temperature Range 32°F to 120°F (0°C to 49°C) Humidity 10% to 93% Non -condensing Wiring Range on all terminals 22 to 12 AWG Dimensions 4.625" H x 4.25" W x 1.125" D Mounting Typically mounted on a standard 4" square box. Ordering Information Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. U.S.A. j 4575 Witmer Industrial Estates Off__� For complete and accurate technical information relating to Niagara Falls, NY 14305 ��� performance, installation, testing and certification, refer to technical Toll Free: (888) 660-4655 T. literature. This document contains intellectual property of Mircom. The information is subject to change by Mircom without notice. Fax Toll Free: (888) 660-4113 Intertek Mircom does not represent or warrant correctness or completeness. www.mircom.com CAT. 9508 Rev. 3 INTELLIGENT NAC EXPANDERIPOWER SUPPLY Description Mircom's INX-10A is an Intelligent NAC expander/power supply that works on the addressable initiating circuit (SLC/ DCL) of the listed compatible Intelligent fire alarm control panels, or, as a NAC expander of any UL/ULC listed 24VDC conventional fire alarm control panel. Available in a 10 Amp configuration, the INX-10A can extend the power capabilities of existing notification appliance circuits as well as provide power for other ancillary devices. In addition, the INX-10A has the ability to operate with any UL/ULC Listed 24 VDC fire alarm control panel to provide Notification Appliance Circuit expansion. The INX-10A is equipped with five individual Class B (Style Y) or Class A (Style Z) output circuits that can be independently configured for NAC operation or auxiliary power. The INX-10A provides the option of configuring all five circuits as an output to provide general purpose power. Output circuits four and five can be configured to provide auxiliary power for four -wire detectors or door holders. Each output circuit is rated for 2.5 Amps. When configured for NAC operation the outputs can be set for Steady, Temporal Code, California Code or March Time. In addition the output circuits have field selectable built-in strobe and horn synchronization protocols to support Mircom, Amseco, System Sensor, Wheelock and Gentex devices, eliminating the need for additional external synchronization modules. c,Tl� L FM u� s o FR I�w APPROVED Features INX-10A • Supports multiple intelligent protocols, MGC Protocol* plus Classic Loop Interface Protocol (CLIP). • Listed with UL 864, 10th Edition and ULC S527-11. 3rd Edition • 10 Amp output • 120V 60Hz / 240V 50Hz operation • Compatible with the following panels: FX-4000N Series, FX-2000N Series, FX-2000 Series, FX-401, FX-400, FX-3500 & FX-3318. Complete list of compatibe panels can be found in LT-899 INX-10A Installation and Operation Manual • Compatible with any UL/ULC listed 24VDC conventional fire alarm control panel to provide Notification Appliance Circuit expansion • Easily configured using DIP switches • One isolated SLC input for connection to the host panel • Five Class B (Style Y) or Class A (Style Z) synchronized output circuits • DC regulated outputs • Configurable AC Power fail delay • Ground fault enable or disable • Option available on configuration to enable or disable the battery charger on activation • From 7 to 15 Address functions (Combination of inputs and outputs, depending on the application) • Outputs individually controllable • Separate Relay for Ground Fault and Common Trouble available on terminals • Horn/Strobe synchronization protocols include Mircom, Amseco, Gentex, System Sensor and Wheelock • Two -wire horn/strobe Sync Mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate • Audible signals may be configured for Steady, Temporal Code, California Code and March Time • Output circuits four and five can be configured to provide auxiliary power for four -wire detectors or door holders. • Supports Canadian two stage operation • Output fault notification to fire alarm control panel • Ability to sync outputs for multiple INX-10A units • 2.5 Amp max. current per output • 1.7 Amp auxiliary power output • Built-in charger for sealed lead acid or gel type batteries • Unit includes power supply, charger, red door, black backbox, transformer and battery leads * Minimum SO-229 Ver 2.7.3 and minimum MD-950 [M] CATALOG NUMBER NOT TO BE USED FOR INSTALLATION PURPOSES. THIS INFORMATION IS FOR MARKETING PURPOSES ONLY AND NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. 5321 Modes of Operation Intelligent NAC Expander (INX) Modes The INX-10A features three modes of NAC Expander operation: • INX Mode with Internal Sync • INX Mode with External Sync • INX Mode with Redundant Input Input Mode with Internal Sync In this mode all signal and sync strobe rates are produced in the INX-10A. INX Mode with External Sync When one of the Sync Inputs is activated, the INX-10A outputs follow the signal pattern of the Sync Input. The NX-10A must be configured as a slave to operate in this mode. INX Mode with Redundant Input The system continuously monitors the SLC loop. If there is no activity for a notable time, an SLC trouble is generated. While the SLC trouble is active, if either of the Sync Inputs are activated then all NAC outputs follow. Specifications Dimensions 20"H x 14'/2"W x 4'h"D AC Line Voltage 120V 60Hz / 240V, 50Hz, 2 Amps / 1 Amp (primary) NAC Circuits 24VDC regulated, Power Limited 10A Total, 2.5A maximum per circuit 24VDC, Gel-Cell/Sealed Lead -Acid Charging Capability Up to 40 AH batteries SupplyCurrent Consumption from INX-10(A) Power Standby 200 mA Alarm 350 mA ConsumptionCurrent . 4.5mA Ordering Information Power Supply Modes In addition to the NAC expander modes, some or all of the NAC outputs on the INX-10A can be configured for the following power supply modes of operation: • NAC Outputs as Power Supply Outputs • NAC Outputs for Door Release • NAC Outputs for 4-Wire Smoke Supply NAC Outputs as Power Supply Outputs This mode allows any NAC output to be configured as a power supply. The SLC and Sync inputs are ignored for the power supply outputs. NAC Outputs for Door Release This mode allows NAC circuits 4 and/or 5 to provide power for door holders. NAC Outputs for 4-Wire Smoke Supply This mode allows NAC circuits 4 and/or 5 to provide auxiliary power for 4-wire smoke detectors. %lki, Mircom THIS INFORMATION IS FOR MARKETING PURPOSES ONLYAND euln'lak NOT INTENDED TO DESCRIBE THE PRODUCTS TECHNICALLY. Canada For complete and accurate technical information relating to performance, installation, testing 25 Interchange Way Vaughan, ON L4K 5W3 Intertek and certification, refer to technical literature. This document contains intellectual property of Telephone: (905) 660 4655 Fax: (905) 660-4113 Mircom. The information is subject to change by Mircom without notice. Mircom does not represent or warrant correctness or completeness. All rights reserved. All other trademarks U.S.A. and registered trademarks are properties of their respective owners. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 1 Fax Toll Free: (888) 660-4113 CAT. 5321 www.mircom.com Rev. 8 Eluxa horns, horn strobes, & strobes Description The Wheelock Eluxa horns, horn strobes, and strobes by Eaton feature an advanced power saving LED technology with a full range of low and high candela settings for indoor wall and ceiling -mount applications. Designed in sleek, modern enclosures, Eluxa's aesthetically pleasing low profile will blend with the building's interior decor. ..,..,: High efficiency, LED technology -': Eaton's high energy efficient technology leads the industry in lowest current draw for a combined high and low candela device, which reduces overall power consumption. As the first notification T appliances in the industry to utilize LED as the light source, this m breakthrough optical design, resulting in best -in -class efficiency, enables material and system cost savings, allowing for a greater :_ram number of appliances on the notification appliance circuit and fewer w1 power supplies. This reduces installation and operating costs. All strobe models feature six candela settings: 15, 30, 75, 110, 135, 185 cd on wall models and 15, 30, 75, 110, 150, 177 cd on ceiling models. �HI Low profile design and rich feature set With the industry's smallest footprint, the Eluxa horns, horn strobes, and strobes are aesthetically pleasing to building owners as the i low profile design does not detract from the interior decor. Eluxa is feature rich with 6 candela settings and 3 horn patterns (Continuous, T3, T3/T4) in 1 device, pre-wire/pre-test via mounting plate with �J hinged feature for ease -of -installation, single -gang design (wall models), and no tools needed for setting changes. The ELST strobe, ELHS horn strobe, and the ELHN horn are for 24V operation. ELHN is suitable for 12V applications. Approvals and synchronization Eaton's Eluxa strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. The Eluxa notification appliances are listed under UL Standards 1971, 1638, and 464 and under CAN/ULC-S525 and CAN/ULC-S526. The appliances are Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the Eluxa product line has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to be compatible with Exceder LED3 and Wheelock RSS strobe -based products including the RSS, CH, E, EH, ET, ST, HS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Eluxa strobes in the same notification zone and field of view with any Wheelock RSS and Exceder LED3 strobe models. FM,T* N Powering Business Worldwide Technical Data TD450157EN Effective April 2021 Eluxa horns, horn strobes, & strobes Features • Energy efficient • LED technology provides industry's lowest current draw • Fewer power supplies required, smaller wire gage, reduced wire runs • Low -profile design • One of the smallest, most compact single -gang designs • Sleek, modern aesthetics with no visible mounting screws • Special lettering available • 6 Field selectable settings in 1 device • Wall: 15, 30, 75, 110, 135, 185 cd • Ceiling: 15, 30, 75, 110, 150, 177 cd • 3 horn patterns • Continuous,T3, andT3/T4; Fire and CO signaling in 1 device • Sound pressure (Anechoic) dBA • Low 86, High 91 (for Continuous, T3, and T4) • Easy -to -install • Mounting plate included with all models: Convenient capture hinge allows installers to easily hold the device while fastening the single -mount screw in place. • Pre-wire/pre-test capability to check for wiring and ground faults prior to appliance installation • Finger slide switches --No tools needed for setting changes • IN/OUT screw terminals using #12 to #18 AWG wires • Mounting options include ELSBB, any single -gang backbox and to 4" square with adapter kit for wall models and LSPKBB-C backboxes, 4" square, 1 1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling models • Strobe synchronization • Meet synchronizing standards with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products • Ability to mix xenon and LED strobes in the same field of view • Compliance • NFPA 72 2016 - 20 ms flash duration requirements • U L 1971, U L 1638, U L 464, U LC-S525, U LC-S526 • California State Fire Marshal (CSFM) • RoHS • FCC Part 15, ICES Note: Please read these specifications and associated installation instruc- tions, before using, specifying, or installing this product. Visit Eaton.com/ Lifesafetynotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range:' Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective strobe intensity based on UL 1971. Drawings .39 Figure 1. Wall, horn strobe Figure 2. Ceiling, horn strobe Table 1. Horn ratings per UL/ULC Anechoic Eluxa Horns Regulated Voltage High Low Model Range VDC dB dB ELHN/ELHNC 8.0 - 17.5 0.025 0.020 ELHN/ELHNC 16.0 - 33.0 0.028 0.021 2 EATON www.eaton.com Eluxa horns, horn strobes, & strobes Technical Data TD450157EN Effective April 2021 Table 2. Strobe ratings UL/ULC Max Current ,O 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELST 16.0-33.0 0.022 0.030 0.060 0.086 0.125 0.185 ELSTC 16.0-33.0 0.022 0.030 0.060 0.086 0.125 0.185 Table 3. Code 3 horn strobe ratings UL/ULC Max Current ,C at Anechoic High continuous Eluxa Horn Strobes 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELHS 16.0-33.0 0.037 0.046 0.077 0.109 0.146 0.208 ELHSC 16.0-33.0 0.037 0.046 0.077 0.109 0.146 0.208 UL/ULC Max Current ,O at Anechoic Low continuous Eluxa Horn Strobes 24VDC Regulated Voltage Model Range VDC 15 30 75 110 135 150 177 185 ELHS 16.0-33.0 0.030 0.039 0.070 0.102 0.139 0.201 ELHSC 16.0-33.0 0.030 0.039 0.070 0.102 0.139 0.201 Table 4. Specification & Ordering Information Sync w/ DSM or Model Mounting Strobe Candela Red White Lettering Wheelock Power Supplies Horn strobes ELHSR Wall 15/30/75/110/135/185 X FIRE X ELHSW Wall 15/30/75/110/135/185 X FIRE X ELHSR-A Wall 15/30/75/110/135/185 X AGENT X ELHSR-N Wall 15/30/75/110/135/185 X No Lettering X ELHSW-A Wall 15/30/75/110/135/185 X AGENT X ELHSW-AL Wall 15/30/75/110/135/185 X ALERT X ELHSW-N Wall 15/30/75/110/135/185 X No Lettering X ELHSW-EV Wall 15/30/75/110/135/185 X EVACUATE X ELHTRC Ceiling 15/30/75/110/150/177 X FIRE X ELHTWC Ceiling 15/30/75/110/150/177 X FIRE X Strobes ELSTR Wall 15/30/75/110/135/185 X FIRE X ELSTW Wall 15/30/75/110/135/185 X FIRE X ELSTR-A Wall 15/30/75/110/135/185 X AGENT X ELSTR-AL Wall 15/30/75/110/135/185 X ALERT X ELSTW-A Wall 15/30/75/110/135/185 X AGENT X ELSTW-AL Wall 15/30/75/110/135/185 X ALERT X ELSTW-N Wall 15/30/75/110/135/185 X No Lettering X ELSTR-N Wall 15/30/75/110/135/185 X No Lettering X ELSTW-EV Wall 15/30/75/110/135/185 X EVACUATE X ELSTRC Ceiling 15/30/75/110/150/177 X FIRE X ELSTWC Ceiling 15/30/75/110/150/177 X FIRE X ELSTRC-AL Ceiling 15/30/75/110/150/177 X ALERT X ELSTWC-AL Ceiling 15/30/75/110/150/177 X ALERT X ELSTWC-EV Ceiling 15/30/75/110/150/177 X EVACUATE X Horns ELHNR Wall X No Lettering X ELHNW Wall X No Lettering X ELHNRC Ceiling X No Lettering X ELHNWC Ceiling X No Lettering X Accessories ELSBB-R LED Backbox, wall ELSBB-W LED Backbox, wall ESB-KIT-R Trim Plate, wall ESB-KIT-W Trim Plate, wall LSPKBB-CR Backbox, ceiling LSPKBB-CW Backbox, ceiling O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v for 24v units). For strobes the UL max current is usually at the minimum listed voltage (16v for 24v units). For audibles the max current is usually at the maximum listed voltage (33v for 24v units). For unfiltered FWR ratings, see installation instructions. (2) Regulated Voltage Range-VDC Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. EATON www.eaton.com Technical Data TD450157EN Eluxa horns, horn strobes & strobes EffectiveApril 2021 Table 5. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating Weight Wall: 0.35 Ibs; Ceiling: 0.55 Ibs Lens Light Emitting Diode (LED) in a rugged Lexan lens Dimensions Wall: 4.79"H x 2.76" W x 1.18" D, Trimplate: 5.25" H x 4.58" W x 0.32" D; Ceiling: 6.27" Diameter x 1.69" D Operating Temperature Indoor: 32°F to 122°F WC to 50°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) Mounting plate included with all models. ELHS and ELST are for wall -mount applications only. ELHN can be used for wall and ceiling -mount applications. Wall mounting: Single -gang, ELSBB backboxes or to 4" square with adapter kit. ELHN can be used for wall and ceiling -mount applications. ELHSC and ELSTC are for ceiling mount applications only. The ELHNC can also be used for wall -mount applications. Ceiling mounting: LSPKBB-C backboxes or to 4" square, 1 1/2" or 21/8"and Octagonal, 1 %s" or 2 1/8"deep Wire Connections #12 through #18 AWG Power & General Operating voltage 12 VDC/VFWR: 8 - 17.5 VDC/VFWR; 24 VDCNFWR: 16 - 33 VDC/VFWR (12 VDC ELHN/ELHNC models only) Strobe Output Rating UL 1971, UL 1638, ULC S526: Selectable 15, 30, 75, 110, 135, 185 candela output for wall models; Selectable 15, 30, 75, 110, 150, 177 candela output for ceiling models Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS Power Supplies or SAFEPATH products, using Wheelock patented svnc protocol Architects and Engineers Specifications The LED notification appliances shall be Wheelock® ELHS audible visual strobe appliances, ELST visual strobe appliances and ELHN audible appliances for wall and ceiling -mount applications with a low - profile design or approved equals. Special lettering, including AGENT, ALERT, EVACUATE, and no lettering, shall be available. The ELHS and ELST strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing -Impaired) for Indoor Fire Protection Service and UL 1638 (Visible Signaling Devices. The ELHS and ELHN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All models shall meet the requirements of FCC Part 15 and ICES-003. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 16 to 33 VDC/VFWR. The ELHS audible strobe and ELST strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Light Emitting Diode (LED) as the light source with a rugged Lexan® lens. The appliances shall be of low current design. The LED strobe flash duration shall be 20 ms. Where Multi -Candela appliances are specified, the strobe intensity shall have 6 field selectable settings at 15, 30, 75, 110, 135 and 185 candela for wall mount applications and 15, 30, 75, 110, 150 and 177 for ceiling applications. The selector switch for selecting the candela shall be tamper resistant. Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a choice of three (3) horn patterns (high & low WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Life safety & mass notification solutions - 273 Branchport Ave. Long Branch, NJ 07740 Powering Business Worldwide Eaton.com/Lifesafetynotification output): Continuous, T3, and T3/T4 for fire (T3) and CO (T4) signaling The ELHS audible strobe, ELST strobe, and ELHN audible shall include a hinged mounting plate. Mounting options shall include LED backboxes, single -gang backbox and to 4" square with adapter kit for wall -mount models and LED Ceiling backboxes, 4" square, 1 1/2" or 2 1/8"deep and 4" Octagonal, 1 1/2" or 2 1/8"deep for ceiling models. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. The ELHS, ELHN and ELST wall models shall have a low profile measuring 4.79"H x 2.76"W x 1.18"D. The ELHSC, ELHNC and ELSTC ceiling models shall have a low profile measuring 6.27" Diameter with 1.69"D. When synchronization is required, the appliance shall be compatible with Wheelock®'s DSM Sync Modules, PS Power Supplies, SAFEPATH products or other manufacturer's panels with built-in Wheelock@ Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash - rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® patented sync protocol. NFPA 72 2016, UL 1971, UL, 1638, UL 464 ULC-S525-16, ULC-S526- 16, CSFM, FCC, RoHS, ICES © 2021 Eaton All Rights Reserved Printed in USA Publication No. TD450157EN April 2021 Eaton is a registered trademark. All other trademarks are property of their respective owners. Eluxa low frequency sounders and sounder strobes Description Eaton has developed the Wheelock Eluxa low frequency sounders (ELFHN) and sounder strobes (ELFHS) to meet the National Fire Protection Association (NFPA 72) low frequency sounder requirements for sleeping rooms for both fire alarm and carbon monoxide (CO) signaling. In a single device, the Eluxa low frequency sounders features both low and high candela settings and alarm signals for dual applications-T3 (fire) andT4 (CO) tones. High efficiency, LED technology Eaton's high energy efficient technology leads the industry in lowest current draw across the full candela range, which reduces overall power consumption and costs in fire alarm systems. As the first notification appliances in the industry to utilize LED as the light source, this breakthrough and patented optical design, resulting in best -in -class efficiency, enables material and system cost savings, allowing for a greater number of appliances on the notification appliance circuit and fewer power supplies. All strobe models feature 110 and 177 candela settings for both wall- and ceiling- mount models. Low profile design and rich feature set With the industry's smallest footprint, the Eluxa low frequency sounders and sounder strobes are aesthetically pleasing as the low profile design does not detract from the interior decor. Eluxa is feature rich with low and high candela settings and 3 horn patterns (Continuous, T3, T3/T4) in 1 device, pre-wire/pre-test via mounting plate with hinged feature for ease -of -installation, and no tools needed for setting changes. These products are suitable for indoor wall and ceiling mount applications. The ELFHS and ELFHN models are for 24V operation. Special lettering, ALERT, CO, and no lettering, is available. Approvals and synchronization Eaton's Eluxa strobes meet the 20 millisecond light pulse duration requirements of the 2016 edition of NFPA 72. By meeting this latest requirement, xenon and LED devices can now be in the same field of view. The Eluxa notification appliances are listed under UL Standards 1971, 1638, and 464 and under CAN/ULC-S525 and CAN/ULC-S526. The appliances are Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the Eluxa product line has been UL/ULC listed as compatible with all Fire Alarm Control Panels (FACP) and accessories that have been determined to be compatible with Exceder LED3 and Wheelock RSS strobe -based products including the RSS, CH, E, EH, ET, ST, HS, MT, S8, SA, STH and Z Series. The listing also includes the ability to install the Eluxa strobes in the same notification zone and field of view with any Wheelock RSS strobe and Exceder LED3 models. F I .T*N Powering Business Worldwide Technical Data TD450159EN Effective September 2021 Eluxa low frequency sounders and sounder strobes Features • Meets NFPA 72 fire and CO low frequency sounder codes for sleeping rooms in a single device • 3 horn patterns • Continuous, T3, and T3/T4; Fire and CO signaling in 1 device • Energy efficient • LED technology provides industry's lowest current draw • Low -profile design • Smallest footprint with sleek, modern aesthetics • Special lettering available: ALERT, CO, no lettering • Field selectable candela settings: 110, 177 cd • Easy -to -install • Mounting plate included with all models: Convenient capture hinge allows installers to easily hold the device while fastening the single -mount screw in place. • Finger slide switches —No tools needed for setting changes • Built-in level adjustment feature and snap -on grille cover • IN/OUT screw terminals using #12 to #18 AWG wires • Mounting Options: ELSPKBB backboxes, single -gang backboxes and 4" square backboxes for wall models and LSPKBB-C backboxes and 4" square, 2 1/8" deep backboxes for ceiling models. • Strobe synchronization components • Meet synchronizing standards with Wheelock's DSM Sync Modules or Power Supplies • Compliance • NFPA 72 2016 - 20 ms flash duration requirements • UL 1971, UL 1638, UL 464, ULC S525, ULC S526 • California State Fire Marshal (CSFM) • ADA/NFPA/ANSI/OSHA • RoHS Note: Please read these specifications and associated installation instructions, before using, specifying, or installing this product. Visit Eaton. com/Lifesafetynotification for current installation instructions. General Notes • Strobes are designed to flash at 1 flash per second minimum over their "Regulated Voltage Range:' Note that NFPA-72 specifies a flash rate of 1 to 2 flashes per second and ADA Guidelines specify a flash rate of 1 to 3 flashes per second. • All candela ratings represent minimum effective Strobe intensity based on UL 1971. Settings The 520 tone is generated within the appliance itself. When the selector switch is set forT3, the sound pattern is also generated within the appliance. When the selection switch is set to continuous, the product is listed for coded operations. TheT3/T4 pattern or other pattern must be generated by the FACP according to the alarm condition sensed by the panel (fire or CO alarm). When the device is set toT3/T4, the appliance can switch fromT3 to T4 based upon the condition sensed by the FACP and passed to the Wheelock DSM module. Drawings Figure 1. Wall Low Frequency Sounder Strobe 1.89 135 0527 °°0000000°°° O O °°°°°°Q°°°° °°°O°°°°°°°°°°°°°° ° °.p°O °°° °°O O°° ° ° O° °° °%°% °° °° O°O° °O°O °° °° 0°0° °0°0 °° °° °°°°°°°°°°°°O°O °°0000:t 0.0000°°°° Figure 2. Ceiling Low Frequency Sounder Table 1. Horn Only Current Draw UUULC Max Current O Eluxa Sounders 24VDC Model Horn Settings 16.0-33.0 ELFHN/ELFHNC Continuous 0.098 Code 3 0.098 Code 3/Code 4 0.098 Table 2. Horn Strobe Current Draw UL/ULC Max Current O Eluxa Sounder Strobes Regulated Voltage Model Range VDC 110 177 ELFHS 16.0-33.0 0.164 0.256 ELFHSC 16.0-33.0 0.164 0.256 O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v). For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation instructions. 2 EATON www.eaton.com Technical Data TD450159EN Effective September 2021 Eluxa low frequency sounders and sounder strobes Table 3. Sound Output (SPL) - UL Table 4. Sound Output (SPL)- ULC ELFHS/ELFHN 24V ELFHS/ELFHN Reverberant dBA per UL 464 O dBA per ULC S525-160 Description 16.OV 24.OV 33.OV Description 16.OV 24.OV 33.OV Continuous 80 80 80 Continuous 80 80 80 Code 3 80 80 80 Code 3 80 80 80 Code 3/Code 4 e 80 80 80 Code 3/Code 4 80 80 80 Table 5. Specification & Ordering Information Sync w/ DSM or Model Strobe Candela Mounting Red White Lettering Wheelock Power Supplies Sounder Strobes ELFHSR 110, 177 Wall X FIRE X ELFHSW 110, 177 Wall X FIRE X ELFHSR-AL 110, 177 Wall X ALERT X ELFHSW-AL 110, 177 Wall X ALERT X ELFHSR-CO 110, 177 Wall X CO X ELFHSW-CO 110, 177 Wall X CO X ELFHSR-N 110, 177 Wall X No Lettering X ELFHSW-N 110, 177 Wall X No Lettering X ELFHSRC 110, 177 Ceiling X FIRE X ELFHSWC 110, 177 Ceiling X FIRE X ELFHSRC-AL 110, 177 Ceiling X ALERT X ELFHSWC-AL 110, 177 Ceiling X ALERT X ELFHSRC-CO 110,177 Ceiling X CO X ELFHSWC-CO 110,177 Ceiling X CO X ELFHSRC-N 110,177 Ceiling X No Lettering X ELFHSWC-N 110,177 Ceiling X No Lettering X Sounders ELFHNR Wall X FIRE X ELFHNW Wall X FIRE X ELFHNR-AL Wall X ALERT X ELFHNW-AL Wall X ALERT X ELFHNR-CO Wall X CO X ELFHNW-CO Wall X CO X ELFHNR-N Wall X No Lettering X ELFHNW-N Wall X No Lettering X ELFHNRC Ceiling X FIRE X ELFHNWC Ceiling X FIRE X ELFHNRC-AL Ceiling X ALERT X ELFHNWC-AL Ceiling X ALERT X ELFHNRC-CO Ceiling X CO X ELFHNWC-CO Ceiling X CO X ELFHNRC-N Ceiling X No Lettering X ELFHNWC-N Ceiling X No Lettering X Accessories Description Red White ELSPKBB-R Eluxa Backbox Wall X ELSPKBB-W Eluxa Backbox Wall X LSPKBB-CR Exceder LED Backbox Ceiling X LSPKBB-CW Exceder LED Backbox Ceiling X O RMS current ratings are per UL maximum RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33v). For strobes the UL max current is usually at the minimum listed voltage. For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation instructions. Note: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Eaton standard terms and conditions. 3 EATON www.eaton.com Technical Data TD450159EN Eluxa low frequency Effective August 2021 sounders and sounder strobes Table 6. Specifications Physical Material Red or white textured UV stabilized, colored impregnated engineered plastic. Exceeds 94V-0 UL flammability rating Weight 1.10 lbs. Lens Light Emitting Diode (LED) in a rugged Lexan lens Dimensions Wall: ELFHN - 6.35"H x 4.56" W x 1.54" D; ELFHS: 6.35"H x 4.56" W x 1.54" D; ELFHNC: 6.27" Diameter x 1.9" D; ELFHSC: 6.27" Diameter x 2.29" Depth Operating Temperature Indoor: 32°F to 122°F VC to 50°C) and maximum humidity of 93% Mounting & Wire Connections Mounting (indoor only) Wall and ceiling -mount applications (model dependent). Mounting Options: ELSPKBB backboxes, single -gang back - boxes and 4" square backboxes for wall models and LSPKBB-C backboxes and 4" square, 21/8" deep backboxes for ceiling models. Wire Connections #12 through #18 AWG Power & General Operating voltage 24 VDCNFWR: 16 - 33 VDCNFWR Strobe Output Rating UL 1971: Field selectable candela 110, 177 cd Strobe Flash Rate Strobes are designed to flash at 1 flash per second Synchronization Models Strobes can be synchronized with Wheelock's DSM Sync Modules, PS Power Supplies, using Wheelock patented sync protocol Temporal Audible Pattern Continuous, Code 3, or Code 3/Code 4 Sync Control. The Code 3 temporal pattern (1/2 second on, 1/2 second off, 1/2 second on, 1/2 second off, 1/2 second on, 1-1/2 off and repeat) is specified by ANSI and NFPA 72 for standard emer- gency evacuation signaling. The Code 4 temporal pattern (four cycles of 100 milliseconds ± 10 percent "on" and 100 milliseconds ± 10 percent "off," followed by 5 seconds ± 10 percent "off►is specified by NFPA 720. Architects and Engineers Specifications The low frequency sounders and sounder strobes appliances shall be Eluxa series ELFHN sounder and ELFHS sounder strobe for wall -mount applications and ELFHNC and ELFHSC for ceiling -mount applications or approved equals. The sounders shall be UL Listed under UL 464 for Fire Protective Service and ULC S525. Sounders equipped with strobes shall be listed under UL 1971 for Emergency Devices for the Hearing -Impaired, UL 1638, and ULC S526. The series shall be Restriction of Hazardous Substances (RoHS) compliant and contain no mercury or other hazardous substances. In addition, the sounder strobes shall meet the requirements of FCC Part 15 and ICES-003. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 16 to 33 VDC. The ELFHS sounder strobe shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Light Emitting Diode (LED) as the light source with a rugged Lexan® lens. The strobe shall be of low current design. The LED strobe flash duration shall be 20 ms or less. The strobe intensity of ELFHS models shall have field selectable of 110 and 177 candela. The audible shall have a minimum of 3 modes of operation: T3 (fire), Continuous, and T3/74 Sync Control. The ELFHS and ELFHN shall be designed with a low profile design for indoor surface or flush mounting. Mounting options shall include ELSPKBB backboxes, single -gang backboxes, and 4" square ��P wrIIMEM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions _ 273 Branchport Ave. Long Branch, NJ 07740 Powering Business Worldwide Eaton.com/Lifesafetynotification backboxes for wall models and LSPKBB-C backboxes and 4" square, 2 1/8" deep backboxes for ceiling models. The sounder and sounder strobe shall incorporate a mounting plate with a snap -on grille cover and shall mount to standard electrical hardware requiring no additional trimplate or adapter. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). All notification appliances shall be backwards compatible. The ELFHN and ELFHS wall models shall have a low profile mea- suring 6.35"H x 4.56" W x 1.54" D. ELFHNC and ELFHSC ceiling models shall have a low profile with a diameter measuring 6.27" and depth of 2.29" Finish shall be red or white. Special lettering, ALERT, CO and No lettering, shall be available. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules, PS Power Supplies, or other manufacturer's panels with built-in Wheelock Patented Sync Protocol. The strobes shall not drift out of synchro- nization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non -synchronized flash -rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock patented sync protocol. UL 1971, UL 1638, UL 464, ULC S525, ULC S526, CSFM, FCC, RoHS, ICES © 2021 Eaton All Rights Reserved Printed in USA Publication No.TD450159EN September 2021 Eaton is a registered trademark. All other trademarks are property of their respective owners. Weatherproof appliances, Version 2 E I Description Designed for life safety, performance and reliability, the Wheelock weatherpoof notification appliances nclude: Weatherproof Appliances Strobes Series RSSWP Horn strobes ASWP Horn AH-24WP AH-12WP Multitone horn strobes MTWP Multitone horns MT Speaker strobes ET70WP Speakers ET-1010 All strobe models are UL dual listed —meeting both UL1638 and UL1971 requirements. As dual listed appliances, these weatherproof strobes, horn strobes and speaker strobes are listed for outdoor applications under UL 1638 as well as under UL 1971, the Standard for Safety Signaling Devices for Hearing Impaired. With an extended temperature range of —40°F to 150°F (-40°C to 66°C), Wheelock weatherproof appliances meet or exceed UL outdoor test requirements for rain, humidity and corrosion resistance while providing multiple strobe intensity options, including the highest strobe ratings available for area coverage per NFPA 72 strobe spacing tables (up to 185 candela for wall mounting and 177 candela for ceiling mounting). FM,TO N Powering Business Worldwide To enable weatherproof mounting, Eaton provides the industry's widest choice of mounting options for surface or unique semi -flush installation. Models are available for surface mounting to Wheelock weatherproof backboxes on walls or ceilings. The optional WP-KIT allows the weatherproof backboxes (1O13, WPBB or WPSBB) to be mounted to a recessed electrical box for concealed conduit installation. For semi -flush installation, the WPA* and WFPA* kits allow a customer to mount the weatherproof appliances to a recessed electrical box without the need for an external weatherproof backbox. See Table 10 on page three of this document for a summarization of these mounting options and the required accessories. All models may be synchronized using the Wheelock DSM sync modules, Wheelock power supplies or other manufacturers panels incorporating the Wheelock patented sync proto- col. The horn output of horn strobes can be independently controlled on 2-wire circuits using the Wheelock patented sync protocol. MTWP horn strobe models are 4-wire appliances; the strobes can be synchronized while the audible can be connected to a coded fire alarm system. MT horns may be synchronized, using the temporal Code 3 horn setting. Technical Data TD450112EN February 2019 Wheelock AH, AS, MT, RSS, ET70 Features & benefits • Weatherproof with extended temperature range of —40°F to 150°F (-40°C to 66°C)* • Dual Listed strobe models (UL 1638 and UL 1971) • Industry's highest strobe candela options • Strobes and Code 3 horn synchronize using the Wheelock Sync Modules or panels with built-in Wheelock Patented Sync Protocol • Models with field selectable tone, dBA and candela settings • Wall or ceiling mounting options • Surface or semi -flush mounting (indoor and outdoor) • IN/OUT wiring termination accepting two #12-18 AWG wires at each terminal Note: Please read these specifications and associated installation instructions, before using, specifying, or installing this product. Visit Eaton.com/massnotification for current installation instructions. Approvals & compliances • Approvals include: UL Standards 1971, 1638, 464 and 1480; ULC, California State Fire Marshal (CSFM); and Factory Mutual (FM) (see agency approvals by model number on pages 4 and 5 of this document) • The series RSSWP ASWP AH-24WP MTWP-2475W, and MT-12/24 have UL/ULC approval down to —40°F. The ET-1010 and ET70WP have UL approval down to —40°F. • Compliance with the following requirements: NFPA; UFC; FCC, ANSI 117.1; OSHA Part 29, 1910.165; AD General notes • Strobes are designed to flash at 1 flash per second minimum over their UL Listed Regulated Voltage Range. • All candela ratings represent minimum effective Strobe intensity based on UL Standards 1971 and 1638 as indicated in candela ratings table. • Models are available in red or white. Contact Customer Service for order code and delivery. Drawings 4.80 0.602 FIRE ° OD I 4.80 oFIRE o IF Figure 1. RSSWP front and side views 4.80 ► � 2.55 + , T.... 4.80 Figure 2. ASWP front and side views a 5.126----� oao 01 oao I 5.126 I Poao 0.65 Figure 3. MTWP front and side views 5.120 0 2 D � ogo$o�o$000000 5.120 ° o°°°o ibo°o oo°moo o°°° °°8°° ° ° °°oo0 0;08888-8o0'0' O °°°moo 'o.. °°° O Figure 4. ET70WP front and side views 5.13 — ' 2.17 0 Alk 5.13 0 2 EATON www.eaton.com Figure 5. MT front and side views Wheelock AH, AS, MT, RSS, ET70 Technical Data TD450112EN February 2019 4 No 4.29 .09 0 0 4.29 0 0 1.92 Figure 6. ET-1010 front and side views Table 1. Maximum RMS current for AH models UL Max Current for AH 24 VDC Table 2. dBA ratings for ET-1010 and ET70WP models UL Reverberant dBA @ 10 ft. Watts High (99) dBA 0.080 Model 1/8 1/4 112 1 2 4 8 Med (95) dBA 0.043 ET-1010 77 80 83 86 87 92 94 Low (90) dBA 0.021 ET70WP 77 88 83 86 88 91 93 Table 3. Maximum RMS current and dBA, MT weatherproof models MTWP/MT MT ULC Anechoic dBA at 10 Feet 24 VDC 12 VDC dBA HI STD HI STD 24 VDC 12 VDC Horn 0.108 0.044 0.177 0.034 92 87 92 87 Bell 0.053 0.024 0.095 0.020 86 80 86 80 March Time 0.104 0.087 0.142 0.034 89 84 89 84 Code 3 Horn 0.122 0.035 0.200 0.034 88 83 88 83 Code 3 Tone 0.135 0.035 0.152 0.021 85 80 85 80 Slow Whoop 0.098 0.037 0.142 0.035 90 85 90 85 Siren 0.104 0.036 0.152 0.030 89 84 89 84 HiAo 0.057 0.025 0.114 0.026 86 81 86 81 Table 4. Strobe and ASWP ratings Candela ratings Maximum RMS Current for ASWP Max RMS Current Strobe Candela UL 1971 UL 1638 @ 77°F UL 1638 @ -40°F (strobe only) High Med Low 2475W 30 O 180 115 0.138 0.168 0.155 0.150 2475C 15 180 115 0.138 0.168 0.155 0.150 135 135 56 0.300 0.355 0.340 0.335 MCWH 185 185 77 0.420 0.480 0.465 0.460 115 115 47 0.300 0.355 0.340 0.335 MCCH 177 177 73 0.420 0.480 0.465 0.460 24185 185 185 77 0.420 24177 177 177 73 0.420 O Wall mount rating only EATON www.eaton.com 3 Technical Data TD450112EN Wheelock AH, AS, MT, RSS, ET70 February 2019 Wall mount models Table 5. Specification and ordering information Agency Approvals Model Number Finish Order Code UL ULC CSFM FM Strobe RSSWP-2475W-FR Red 9013 X X X X RSSWP-2475W-FW White 3034 X X X X RSSWP-24MCWH-FR Red 5161 X X X — RSSWP-24MCWH-FW FIRE White 5165 X X X — Audible strobe ASWP-2475W-FR Red 9012 X X X X ASWP-24MCWH-FR Red 5137 X X X — ASWP-24MCWH-FW White 5140 X X X — Multitone strobe MTWP-2475W-FR Red 8420 X X X X MTWP-2475W-FW White 3112 X X X X MTWP-24MCWH-FR Red 5132 X X X — MTWP-24MCWH-FW White 5134 X X X — Speaker strobe ET70WP-2475W-FR Red 9077 X X X ET70WP-2475W-FW White 3179 X X X ET70WP-24185W-FR Red 4885 X X X ET70WP-24185W-FW White 4891 X X X Ceiling mount models Table 6. Specification and ordering information Agency Approvals Model Number Finish Order Code UL ULC CSFM FM Strobe RSSWP-2475C-FR Red 4338 X X X X RSSWP-2575C-FW White 4446 X X X X RSSWP-24MCCH-FR F R E Red 5167 X X X — RSSWP-24MCCH-FW White 5187 X X X — Audible strobe ASWP-2475C-FR Red 4251 X X X X ASWP-2475C-FW RJR E i White 4502 X X X X ASWP-24MCCH-FR Red 5149 X X X — ASWP-24MCCH-FW White 5157 X X X — Multitone strobe MTWP-2474C-FR Red 4457 X X X X MTWP-2475C-FW White 4458 X X X X MTWP-24MCCH-FR F I R E Red 5102 X X X — MTWP-24MCCH-FW White 5122 X X X — Speaker strobe ET70WP-2475C-FR Red 4452 X X X ET70WP-2475C-FW p White 4454 X X X ET70WP-24177C-FR Iq Red 4845 X X X ET70WP-24177C-FW F White 4859 X X X 4 EATON www.eaton.com Wheelock AH, AS, MT, RSS, ET70 Wall or ceiling mount models Table 7. Specification and ordering information Model Number Finish Technical Data TD450112EN February 2019 Agency Approvals Order Code UL ULC FM Audible AH-24WP-R Red 7416 X X X Horn MT-12/24-R Red 5023 X X X MT-12/24-W White 5024 X X X Speaker ET-1010-R Red 3135 X Available X ET-1010-W 1-71-7- White 3137 X Available X �1-� Mounting accessories Table 8. Ordering information Model Number Finish Order Code Model Number Finish Order Code Backboxes Gasket kit 10B-R O Red 5046 WP-KIT N/A 4486 10B-W O White 5047 Flush plates WFPA-R Red 4698 WFPA-W White 4701 WPSBB-R O Red 9751 WPSBB-W O White 3033 WFP-R Red 4696 WFP-W White 4697 to 13 WPBB-R O Red 9014 10 WPBB-W ,O White 4692 Table 9. Mounting options WBB-R Red 2959 WBB-W White 2960 Surface Mount Flush Mount Exposed Mounting Options Conduit Concealed Conduit RSSWP Strobes WPSBB WPSBB +WP-KIT WFP ET70WP Speaker Strobes 10B 106 + WP-KIT WFP ASWP Horn Strobes WPBB WPBB + WP-KIT WFPA ,p 101B, WPSBB and WPBB models include weep holes and plug in the event that moisture may have AHWP Horns WBB — WFP entered the appliance. ET-1010 Speakers WBB -- WFP MTWP Multitone Strobes 10B 10B + WP-KIT WFP Multitone 10B 10B+WP-KIT WFP Note: Refer to Data SheetTD450028EN for mounting options EATON www.eaton.com 5 Technical Data TD450112EN Wheelock AH, AS, MT, RSS, ET70 Effective February 2019 Architects and engineers specifications General Weatherproof notification appliances shall be UL listed for outdoor use. Weatherproof strobe appliances shall be listed under UL Standard 1638 (Standard for Visual Signaling Appliances) for Indoor/Outdoor use and UL Standard 1971 (Standard for Safety Signaling Devices for Hearing Impaired). The appliances shall be available for optional wall mounting or ceiling mounting to weatherproof backboxes using either exposed conduit, concealed conduit, or semi -flush mounting to a recessed electrical box in walls or ceilings using Wheelock mounting accessories. Weatherproof Strobes and Audibles Weatherproof strobe appliances shall be Wheelock RSSWP models or approved equals. The weatherproof strobes shall produce a mini- mum flash rate of 60 flashes per minute over the UL Regulated Voltage Range of 16 to 33 VDC and shall incorporate a Xenon flashtube. The weatherproof strobes shall be available with UL 1971 candela ratings up to 185 cd for wall mounting and 177 cd for ceiling mounting. UL 1638 candela ratings up to 180 cd at 77°F shall be available. The strobes shall operate over an extended temperature range of —40°F to 150OF (-40°C to 66°C) and be listed for maximum humidity of 95% RH. Strobe inputs shall be polarized for compatibility with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP). Weatherproof audibles shall be Wheelock AH models or approved equals, and the weatherproof audible/strobe combinations shall be Wheelock ASWP models or approved equals. The weatherproof horns and multitone audibles shall be listed for Indoor/Outdoor use under UL Standard 464. The horns shall be able to produce a continuous output or a temporal code-3 output that can be synchronized. The horns shall have at least 3 sound level settings. Horn/strobe combinations shall be able to be synchronized on a single NAC. Multitone audibles shall Wheelock MT models or approved equals. The multitone horns shall be able to produce 8 distinct tones selectable by dip switch and shall have at least 2 sound level settings. Multitone audible/strobe combinations shall have independent inputs for the audible and strobe. The strobes shall be able to be synchronized. When set to Code 3 Horn, the audible shall be able to be synchronized. The audibles shall be able to be coded when operated on a separate NAC. ASWP audibles and strobes shall be able to be synchronized on a 2-wire circuit with the ability to silence the audible if required. The strobes on MT multitone audible/strobe appliances shall be able to be synchronized and shall be able to be operated on a separate circuit from the audibles while the audible circuit is connected to a coded or continuous NAC. When set to Code 3 Horn, the MT multitone audibles shall be able to be synchronized. Weatherproof Speakers and Speaker/Strobes Weatherproof speakers shall be Wheelock ET-1010 models or approved equals, and speaker strobes shall be ET70WP or approved equals. Weatherproof speakers and speaker strobes shall be UL listed for indoor/outdoor use under UL Standard 1480. All speakers shall provide field selectable taps for 1/8W to 8W operation for either 25 VRMS or 70 VRMS audio systems and shall incorporate a sealed back construc- tion for extra protection and improved audibility. Speakers shall be listed to produce up to 94 dBA and shall incorporate a vandal resistant grille design. Speaker strobes shall be available for surface or semi -flush mounting to walls or ceilings and shall be listed to produce up to 93 dBA. Sync Modules When synchronization of strobes or temporal code-3 audibles is required, the appliances shall be compatible with the Wheelock DSM sync modules, Wheelock power supplies or other manufacturers panels with built-in Wheelock patented sync protocol. The strobes and audibles shall not drift out of synchronization at any time during operation. Weatherproof Mounting Accessories Weatherproof mounting options shall include surface mounting or semi -flush mounting to walls or ceilings. Surface mounted appliances shall mount to Wheelock IOB, WBB, WPBB or WPSBB weatherproof backboxes using either exposed conduit or concealed conduit. For concealed conduit the weatherproof backbox shall be mounted to a recessed electrical box with Wheelock's WP-KIT to provide a weatherproof seal for the electrical box. Semi -flush mounted appliances shall mount to a recessed electrical box using Wheelock WFP or WFPA flush plates to provide a weatherproof seal between the electrical box and the appliance. WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3-YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton Life safety & mass notification solutions 273 Branchport Ave. Long Branch, NJ 07740 Eaton.com/massnotification © 2019 Eaton All Rights Reserved - Printed in USA Publication No.TD450112EN Powering Business Worldwide February 2019 Eaton is a registered trademark. All other trademarks are property of their respective owners. (E)POTTER RTS-O/RTS-C h The Symbol of Protection Room Temperature Switch Features • Easily installed • Completely sealed sensor, moisture and vapor resistant • Highly resistant to vibration and corrosion • Highly sensitive to temperature changes • No sensitivity loss due to aging • Repetitive operation without the need to replace sensing elements • Small compact design • Precision and quality at low cost SIGNALING C UL US LISTED Important: This document contains important information on the installation and operation of room temperature switches. Please read all instructions carefully before beginning installation. A copy of this document is required by NFPA 72 to be maintained on site. Description Each unit consists of a bi-metal operating mechanism, featuring hermetically sealed precious metal contacts, N.O. or N.C., which automatically reset for repetitive operation, eliminating the need for sensing element replacement. Small compact design, highly resistant to vibration and corrosion. Easily installed using the enclosed hardware or adhesive mounting pad. Screw terminals permit easy installation in single or multiple detector circuits. Application The RTS Series complies with the requirements of NFPA 13 and 72 for a room temperature switch to operate at 40°F to protect a dry pipe valve from freezing. The RTS can also be used for other temperature detection applications. Operation The normally open detector, RTS-O, will close the contact when the temperature drops below 40°F (4,5°C). The normally closed detector, RTS-C, will open the contact when the temperature drops below 40°F (4,5°C). The detector will automatically reset to the normal state when the temperature rises above 40°F (4,5°C). The RTS Series Room Temperature Sensors are precision engineered, designed and manufactured for commercial or residential use. Technical Specifications Enclosure White ABS Dimensions 2 1/16"W x 3 7/16"L x 1 1/4"H (5,2cm W x 8,7cm L x 3,2cm H) Sensor Epoxy sealed stainless steel case, bi-metallic operating mechanism. Contacts Silver clad, available normally open or normally closed Electrical Rating 1 Amp at 24VDC Temperature Setting 40° ±5°F (4,5° ±3°C) Terminals Screw Terminals Mounting Wall Mount, Surface Potter Electric Signal Company, LLC St. Louis, MO Phone: 866-956-0988 / Canada 888-882-1933 www.pottersignal.com 5401019 - REV H • 09/15 PAGE 1 OF 2 (E)POTTER RTS-O/RTS-C The Symbol of Protection Room Temperature Switch Inspection, Testing, & Maintenance The frequency of inspection and testing of the RTS and its associated monitoring system shall be in accordance with applicable local and NFPA codes and standards. Manufacturer recommends quarterly or more frequently. Functional test can be accomplished by spraying the RTS with circuit cooler or equivalent. More accurate test requires exposing the RTS to 40°F f 5°F. The RTS requires no maintenance other than ensuring the vent holes are not obstructed. Fig 1 RTS-0 RTS-0 Control Unit Supervisory Device EOLR Circuit RTS-C RTS-C Control Unit Supervisory Device EOLR Circuit DWG# 1019-1 NOTE: This RTS does not have duplicate terminals. Do not use looped wire under terminals. Break wire ran to provide supervision of connections. RTS Mounting Template Fig 2 Ordering Information Model Description Stock No. RTS-0 Normally Open Room Temperature 1010108 Switch RTS-C Normally Closed Room Temperature 1010109 Switch Supervisory switches have a normal service life of 10-15 years. However, the service life may be significantly reduced by local environmental conditions. Potter Electric Signal Company, LLC St. Louis, MO Phone: 866-956-0988 / Canada 888-882-1933 www.pottersignal.com 5401019 - REV H • 09/15 PAGE 2 OF 2 EB, Functional Devices, InC.M ` (800) 888-5538 0 sales(afunctionaldevices.com •AMP PILOT CONTROL RIBU1C Enclosed Relay 10 Amp SPDT with 10-30 Vac/dc/120 Vac Coil Wht/Blk Blu 120 Vac N/C Wht/Blu Yel 10-30 Vac/dc Comm Wht/Yel Org Comm N/O SPECIFICATIONS RIBH1C Enclosed Relay 10 Amp SPDT with 10-30 Vac/dc/208-277 Vac Coil Wht/Brn Blu 208-277 Vac N/C WhVBIu Yel 10-30 Vac/dc Comm Wht/Yel Org Comm N/O # Relays & Contact Type: One (1) SPDT Continuous Duty Coil Expected Relay Life: 10 million cycles minimum mechanical Operating Temperature: -30 to 140o F Humidity Range: 5 to 95% (noncondensing) Operate Time: 20ms Relay Status: LED On = Activated Dimensions: 1.70"x 2.80-x 1.50"with .50" NPT nipple Wires: 16", 600V Rated Approvals: UL Listed, UL916, UL864, C-UL California State Fire Marshal Housing Rating: UL Accepted for Use in Plenum, NEMA 1 Gold Flash: Yes Override Switch: No Contact Ratings: 10 Amp Resistive @ 277 Vac 10 Amp Resistive @ 28 Vdc 480 VA Pilot Duty @ 240-277 Vac 480 VA Ballast @ 277 Vac Not rated for Electronic Ballast 600 WattTungsten @ 120 Vac (N/O) 240 WattTungsten @ 120 Vac (N/C) 1/3HP @ 120-240Vac(N/O) 1/6HP @ 120-240Vac(N/C) 1 /4 HP @ 277 Vac (N/O) 1 /8 HP @ 277 Vac (N/C) ® www.functionaidevices.com C (@us � Made In USA LISTED Buy American" of ARRA2009 RIBU 1 C-RD RIBH 1 C-RD Red housing RIBUIC-N4 RIBH? C-N4 NEMA 4X housing, UL508 only Coil Current: 33 mA @ 10 Vac 13 mA @ 10 Vdc 35 mA @ 12 Vac 15 mA @ 12 Vdc 46 mA @ 24 Vac 18 mA @ 24 Vdc 55 mA @ 30 Vac 20 mA @ 30 Vdc 28 mA @ 120 Vac (RIBU1 C) 39 mA @ 208-277 Vac (RIBH1 C) Coil Voltage Input: 10-30 Vac/dc ; 120 Vac; 50-60 Hz (RIBU1 C) 10-30 Vac/dc ; 208-277 Vac; 50-60 Hz (RIBH 1 C) Drop Out = 2.1 Vac / 2.8 Vdc Pull in=9Vac/10Vdc 071417 t lb 1111D 14% pop >oA i9 l r )))) )lit I Standard Features: • Relays may be energized from a voltage source of 18 to 35VDC or VAC, 120VAC or 230VAC • Each relay position contains a red LED, which illuminates when the coil is energized. • Single, dual or triple relay modules may be "snapped apart" from standard 4-position master • DC input is polarized • Continuous duty use • Available in dust resistant enclosures with LED viewing port • /C versions mounted in enclosures • /C/R versions with red covers for NYC and other uses • /T versions come complete with track mounting hardware which facilitates installation in standard cabinets • UL recognized relays rated at 10,000,000 mechanical operations • UL listed as Control Unit Accessory y1 [07] NFP� Made In U.S.A. �- Uses UL Recognized Components MR-100 & MR-200 Series Relays The MR Series Multi -voltage Control Relays offer SPDT or DPDT 10 Amp resistive contacts which may be operated by one of four input control voltages. A single relay may be energized from a voltage source of 24VDC, 24VAC, 120VAC or 230VAC by wiring to appropriate input terminals. Each relay position contains a red LED which indicates the relay coil is energized. Relays may be "snapped apart" from a standard 4 module assembly and used independently. These devices are ideal for applications where local contacts are required for system status, remote contacts for control of electrical loads and general purpose switching. They are suitable for use with HVAC, temperature control, fire alarm, security, energy management and lighting control systems. SPOT CONTACTS 10A RESISTIVE@ 120VAC NC C NO o00 , RELAY ENERGIZEDy I• E ' LED I o INPUT CONTROL 01 VOLTAGE 24(18-35)VDC= 24(18-32)VAC� 120VAC1 N H 230VAC---P- H H TERMINAL STRIP CONECTIONS MR-101 (MR-104) U �C ISO 9001 REGISTERED COMPANY DPDT CONTACTS 10A RESISTIVE@ 120VAC ,ONC C NO NC C NO*, o00000 , RELAY ENERGIZED LED o , INPUT CONTROL 1 • 6 1 VOLTAGE 24(18-35)VDC1 24VAC---m- 120VAC1 N H 230VAC­P� H H TERMINAL STRIP CONECTIONS M R-201 (MR-204) Space Age Electronics, inc. www.lSAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2008 ED0313 LT10278 Rev.B 1/2 No Excuses, Just Solutions! ESPACE AGE LECTRONICS, INC. ssu- ssu- ssu- ssu- ssu- ssu- ssu- ssu- ssu- ssu- ssu- ssu- PRODUCT SPECIFICATIONS rn A I TA rT CAlrl nel 10C 11 * nnC4 rCCRA vviir�v i 1 KAl r\ v- ..�.. .... . MODEL MODULE CONFIGURATION MOUNTED MOUNTED COVER FILE FILE FILE NUMBER: POSITIONS PER POSITION H X W X D H X W X D MATERIAL S3403 73-92-E 7300-1004 3.25" (82mm) MR-101/T 1 SPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-101/C 1 SPDT 5.125" (130mm) ABS-94V0 UOXX Vol.14 3.125" (79mm) 2.50" (63mm) PlasticUOXX2 UOXX7 :101 Red MR-101/C/R 1 SPDT ABS-94V0 Vol. 22 Plastic 3.25" (82mm) MR-104/T 4 SPDT 8.50" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-104/C 4 SPDT 5.125" (130mm) 18ga UOXX 9.50" (241 mm) 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 14 :101 Red MR-104/C/R 4 SPDT 18ga 8ga CRS 3.25" (82mm) MR-201/T 1 DPDT 2.125" (54mm) UOXX2 :106 1.50" (38mm) Grey MR-201/C I 1 DPDT 5.125" (130mm) ABS-94V0 UOXX Vol.16 3.125" (79mm) 2.50" (63mm) PlasticUOXX2 UOXX7 :101 Red MR-201/C/R 1 DPDT ABS-94V0 Vol. 22 Plastic 3.25" (82mm) MR-204/T 4 DPDT 8.5" (215mm) UOXX2 :106 1.50" (38mm) Plated MR-204/C 4 DPDT 5.125" (130mm) 18ga UOXX 9.50" (241 mm) 2.50" (63mm) CRS UOXX2 UOXX7 Vol. 16 :101 8ga MR-204/C/R 4 DPDT CRS COIL VOLTAGE: MR-100: 24(18-35)VDC, 24(18-35)VAC, 120VAC, 230VAC MR-200: 24(18-35)VDC, 24VAC, 120VAC, 230VAC (Pull in voltage: 75% of nominal max. @ 25°C; Drop out voltage: 25% of nominal min. @ 25°C) POLARIZED: DC input only ENERGIZED LED INDICATOR: One per module position CURRENT REQUIREMENT: Per module position: MR-100 Series = 18mA/ MR-200 Series = 40mA CONTACT RATINGS: 7A @ 28VDC / 10A (NO:1/6HP, NC:1/8HP) @ 120VAC / 7A @ 230VAC CONTACT CONSTRUCTION: Dry Form "C" ENVIRONMENTAL: 32°F to 120°F (0°C to 49°C) @ 85% RH (@ 32°F), Non -condensing, Non-freezing WIRING: Solid or stranded; #12 to #22 AWG terminals /T VERSIONS: 3.5" wide, low profile plastic snap track provided with mounting screws /C VERSIONS: Backbox: 18ga CRS, plated with 1/2" conduit knockouts top and bottom Space Age Electronics, inc. www.lSAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! 'UOXX=Control Unit Accessories, System; 2=Component; 7=Certified for Canada This document is subject to change without notice, see doc # ED0479 for legal disclaimer ED0313 LT10278 Rev.B 2/2 O,�� SYSTEM � SENSOR- 5600 Series Mechanical Heat Detectors System Sensor' 5600 series mechanical heat detectors offer a low-cost means for property protection against fire, and for non -life -safety installations where smoke detectors are inappropriate. Features • Multiple configurations for installations: - Single- and dual -circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. • Plain housing for residential installations (Model 5601P) • Easy -to -use terminal screws • A broad range of back box mounting options: - Single gang - 3.5-and 4-Octagonal - 4-square with square to round plaster ring • Reversible mounting bracket Agency Listings & g 0 S2101 3016008 .._.._., 7270-1653:0167 F M LISTED APPROVED l 5621 Multiple configurations. The 5600 series offers a full -line of configurations to accommodate a broad range of applications. Both single- and dual -circuit models are available for low- and high - temperature ratings with either fixed temperature or combination fixed temperature/rate-of-rise (ROR) activation. The ROR element of the fixed/ROR models is restorable to accommodate field-testing. Installation flexibility. To satisfy a variety of installation needs, the 5600 series easily mounts to single -gang and octagonal back boxes. And these models accommodate four -square back boxes, when used with a square to round plaster ring. The reversible mounting bracket permits both flush- and surface -mount back box installations. Visual identification. The 5600 series provides clear markings on the exterior of the unit to ensure that the proper detector is being used. Alphanumeric characters identify the activation method, as well as the temperature rating, in Fahrenheit and Celsius degrees. Fixed temperature models are identified FX, while combination fixed/ rate -of -rise units are marked FX/ROR. The 5600 series also provides a post -activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. Specifications Mechanical heat detector shall be a System Sensor 5600 series model number , listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single -circuit or a dual -circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate -of -rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method. The rate -of -rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing. The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Physical/Operating Maximum Installation Temperature 5601P, 5603, 5621, and 5623: 100°F (38°C) 5602, 5604, 5622, and 5624: 150°F (65.6°C) Operating Humidity Range 5 to 95% RH non -condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623: 135°F (57°C) 5602, 5604, 5622, and 5624: 194°F (90°C) Weight 6 oz. (170 grams) Rate -of -Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P, 5602, 5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage / Contact 6-125VAC / 3A Ratings 6-28VDC / 1A 125VDC / 0.3A 250VDC / 0.1 A Input Terminals 14-22 AWG troy (D 5601 P 5602, 5622 5603, 5623 5604, 5624 5621 Ordering Information 5601 P Single None 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate -of -Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering *NOTE: Refer to NFPA72 guidelines for 194°F (90°C) Fixed Temperature spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 ©2013System Sensor. Phone: 800 SENSOR2 •Fax: 630 377 6495 Product specifications subject to change without notice visit systemsensor.com or current product information, including the latest version of this data sheet. SENSOR® www.systemsensor.com sPos30001 • 7/13 ap � SRD ACE-„ System Record Documents f BY SPACE AGE ELECTRONICS FEATURES • 18 gauge cold rolled steel construction with red powder coat and white lettering • Dimensions are 12" wide x o 13" tall and 2 1 /4" deep LISTED . Stainless steel piano hinge •Two key ring hooks to hold system keys • Business card holder for key contacts • Slide tab allows user to select USB-C or Micro USE; connector to download from 8GB digital flash memory Store important system documents in a secure location with a cabinet built specifically to meet the requirements of NFPA 72 7.7.2.4. The number one goal at Space Age is to manufacture code compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USE; connector to access records electronically (See NFPA 72 7.5.6.7). SPECIFICATIONS The SRD System Record Documents Box shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a powder coat finish. The cover shall be permanently screed with 1" high lettering "SYSTEM RECORD DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and there will be a 12" stainless steel piano hinge. The SRD will have a minimum of 8 gigabyte digital flash memory drive with a slide tab that allows user to select USB-C or Micro USB connector for uploading and downloading information. The enclosure will supply 4 mounting holes. Inside will accommodate standard 8 1/2" x 11" manuals and document records. A legend sheet will be attached to the door for system required documentation, key contacts and system information. The enclosure shall also provide 2 key ring holders with a location to mount standard business cards for key contact personnel. CUSTOM COLORS AND BRANDING AVAILABLE MYOURNMYOURN YOUR YOUR YOUR t. O �. O I. O L- LOGO Pg. 1 /2 ACEBOX DIMENSIONS 1.63 ORDERING INFORMATION �4C�N aCEC�OaD 8S DOOC UNF- 4a P/N# SS000689 System Record Documents Cabinet - Red P/N# SS000690 System Record Documents Cabinet - Red with your custom screened logo P/N# SSU01689 System Record Documents Cabinet - Black P/N# SSU01690 System Record Documents Cabinet - Black with your custom screened logo www.lsae.com I toll free 1.800.486.1723 1 fax 508.485.4740 © Copyright 2018 Space Age Electronics, Inc. I This document subject to change without notice I LT10641 1 Rev. D 13.16 NFPA ADA Pg. 2/2 A c I QOX f BY SPACE AGE ELECTRONICS FLOCK -FA CIRCUIT LOCKOUT KIT • Circuit lockout tab • Hex key • Breaker, legend, and door labels NFPA 2016 CODE COMPLIANCE • 10.6.5.2 Circuit Identification and Accessibility. • 10.6.5.2.1 The location of the branch circuit disconnecting means shall be permanently identified at the control unit. • 10.6.5.2.2 System circuit disconnecting means shall be permanently identified as to its purpose in accordance with the following: (1) "FIRE ALARM" for fire alarm systems (2) "EMERGENCY COMMUNICATIONS" for emergency communications systems (3) "FIRE ALARM/ECS" for combination fire alarm and emergency communications systems • 10.6.5.2.3 For fire alarm and/or signaling systems, the circuit disconnecting means shall have a red marking. • 10.6.5.2.4 The red marking shall not damage the overcurrent protective devices or obscure the manufacturer's markings. • 10.6.5.2.5 The circuit disconnecting means shall be accessible only to authorized personnel. • 10.6.5.3 Mechanical Protection. The branch circuit(s) and connections shall be protected against physical damage. • 10.6.5.4 Circuit Breaker Lock. Where a circuit breaker is the disconnecting means, a listed breaker locking device shall be installed. www.lsae.com I toll free 1.800.486.1723 1 fax 508.485.4740 o. 1,110 �,�o•. �* A \ © Copyright 2019 Space Age Electronics, Inc. I This document is subject to change without notice I SS10101 1 Rev. 2 NFP/► ADA E =. CL h 7H V f BY SPACE AGE ELECTRONICS owNF� s/NCE 19 u� LISTED Features EIZOV= T Hybrid Surge Protection Device An ideal choice for your 120VAC applications, the E120V-GT maintains system integrity and protects against transients introduced into electrical lines via poor atmospheric and utility conditions as well as internally generated inductive loads. Not only is the E-120V-GT robust enough to absorb a spike, but to also clamp long enough to trip the branch circuit breaker and still be functional for additional surges. Reduce downtime associated with power surges and lightning strikes, prevent interruption of recurring monthly revenue based systems, and eliminate non -billable service calls and expensive repairs by protecting your equipment with this invaluable device. • 120 VAC • 10KA Short Circuit Applications Current Rating • ANSI/UL Listed 1449 4th • Fire alarm control panels Edition, Type 2 • Mass notification systems • CSA C22.2 No. 269.2-17 • Dedicated branch circuits 2nd edition, Type 2 • Amplifiers, motors, pumps, and power boosters • Acerbox ELOCK Circuit Lockout Kit included per NFPA 72 2013 10.6.5.2 Specifications • Surface or conduit mounting All 120 VAC equipment will have Transient Voltage Surge • Diagnostic indicator light Suppression (TVSS) protection manufactured by Space Age Electronics, Inc., part number E120V-GT. The unit shall be ANSI/ • Self restoring UL listed to standard 1449, 4th edition and will be labeled • 3 Wire device (18" length) clearly with indelible ink. Can be attached via the 3/a" rigid coupling, or surface mounted via the 2 external mounting holes. The unit shall have thermal fuses to protect against fire in short circuit conditions and will have 18" long, 14 gauge wires (3x) with a green ground wire. The enclosure will be a non dielectric material UL94 QMFZ2/8 grade material providing UV protection. The unit shall provide visual indication (LED) that unit is protecting and functioning. Pg. 1 /2 E=CL//=5 Performance Specifications Short Circuit Current Rating (SCCR): 10kA Enclosure Material: UL94 QMFZ2/8 (green) VPR=700 (L-N) 700 (L-G) 600 (N-G) Capacitance: < 2,000 pf Clamping Response Time: < 5 nanoseconds Current: Non -Load Bearing Max Operating Voltage (MCOV): 140VAC, 50/60 Hz Design: Thermally Fused Hybrid Operation Indicators: LED Max Surge Current: 25kA Energy Dissipation: 500J Clamping Voltage: 230V RMS Operating Specifications Service Voltage: 120VAC Single Phase Circuits Protected: L-N L-G N-G Connection Type: Hardwired Installation Configuration: Parallel Compliance Specifications UL Listed: 1449 4th Edition - VZCA File Number: E319370 Vol. 1 Sec. 1 Dimensions 1.511 O 21 L2.6" 4.4" Wiring Diagram Breaker panel 0 ®® O _� s00000s G www.lsae.com I toll free 1.800.486.1723 1 fax 508.485.4740 47 R� A iso © Copyright 2018 Space Age Electronics, Inc. I This document subject to change without notice I LT10629 I Rev. A NFPA EG'TEpE° ADA Pg. 2/2 AE !q,of SECURITY CORPORATION INNOVATION 7707 Fire Subscribers IntelliNet A Newer, Smarter Alarm Communications Platform Feature Highlights • Leverages state of the art technology • Applies advanced security protection • Offers flexible power and configuration options • Engineered for backward compatibility with legacy systems • Enables future ready capabilities • Provides instant subscriber status through front panel with Power and Trouble LEDs, a backlit LCD display, and Menu/Silence button • Includes robust Multiple Communication Technologies (MCT) feature • Emulates virtual keypad • Improves functionality with an adaptive Graphic User Interface (GUI) for programming via smartphones, tablets and PCs • Plus many more... Key Benefits aA-corp.com__ X com) U NFPA LISTED 0 • Built upon the solid foundation of AES-IntelliNet patented mesh radio technology for use in private licensed wireless networks • Protects subscriber units against unauthorized access and rogue activity with a password -protected Dealer Code • Makes programming and streamlined troubleshooting easy with user friendly interface • Adds integrated supervision of AES-IntelliPro full data module • Provides versatile power options: (1) Direct from the Fire Alarm Control Panel (FACP) without requiring an electrician onsite and without Subscriber backup battery; (2) Directly from the FACP with Subscriber backup battery; or (3) Traditional installation with plug in Class 2 low power transformer • Allows for enhancement upgrades and an expanded number of new features to be added easily with highly flexible and scalable alarm communications infrastructure • Rigorously tested to the highest industry standards and future ready to meet emerging NFPA code and UL standards Enhanced Wireless Fire Alarm Monitoring Powered by AES enhanced mesh radio technology, IntelliNet 2.0 7707 Fire Subscribers are next generation universal wireless communicators that provide advanced security protection for any new or existing alarm monitoring network. The AES Model 7707 is ideal for commercial fire applications. With the AES-IntelliPro full data module option, they are the ideal drop -in replacement for Plain Old Telephone Service (POTS) lines. The red metal enclosure comes with a key lock and front panel LCD backlit display with intuitive view that provides an instant visual of the subscriber status. The user friendly GUI makes it easy to program AES subscriber units via a smartphone, laptop, tablet, or integrated Universal Serial Bus (USB)—without the need for special cables or having to use a handheld programmer. Additional knockouts make it easier to mount for faster installation. IntelliNet 2.0 Private Wireless Mesh Radio Network D) Burglary D _ Subscriber lam. B ---_ .• � 1 — 'ir 1 C � I N B) Fire i Subscriber 1 s AES-Network Management System ' — — — — — — — — — D 1f.I — — B _ — _ _ — — — — — — — Primary AES-MultiNet Receiver I � I A) Alarm 1 � � I Panel Secondary AES-MultiNet Receiver I � � I B rr I B Alarm Automation p——___—_— — C)IPLinks Customer Location I Mesh Radio Technology I Central Monitoring Station Alarm Panel & AES Subscriber Multi -path AES-IntelliNet(g) Network Primary & Secondary AES-MultiNet System sends critical event signal delivers alarm signals via smart routing receives transmission in 1-3 seconds The IntelliNet 2.0 Fire Subscriber has an 8 Zone modular design for expansion with normal and reverse polarity, POTS and DACT interfaces with an option for the 7794A AES-IntelliPro full data module add -on accessory board. AES subscribers' intelligent software automatically detects new hardware and devices to reduce installation time. An AES certified WiFi accessory allows seamless wireless connectivity for configuration and programming. A laptop, Ethernet cable, or a Wi-Fi USB dongle is required for IntelliNet 2.0 programming, handheld programmers will not work with 2.0 units. A FACP Power Supply Adapter is required for certain configurations when using flexible power options. The forward compatible design allows for feature add-ons, engineered to adapt seamlessly with future software upgrades as technology advances. IntelliNet 2.0 allows configuration cloning for faster installation time. The AES 7707 was designed with quick configuration and installation in mind to make it easier for field technicians to get in, out, and on to the next install. Visit our Fire Marshal Resources web page for official NFPA and UL Listings: aes-corp.com/products/fire/fire-marshal-resources How to Order 7707 Fire IntelliNet 2.0 Fire Subscribers 2.0 PREMIUM (UL & ULC Listed) 7707P-88-M IntelliNet 2.0 Fire Subscriber, 8 Zone with Multiple Communication Technologies (MCT), Red Enclosure 7707P-88-ULP-M IntelliNet 2.0 Fire Subscriber, 8 Zone with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 7707P-44-M IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) with Multiple Communication Technologies (MCT), Red Enclosure IntelliNet 2.0 Fire Subscriber, 4x4 Zone (4 Reversing Polarity, 4 Supervised) 7707P-44-ULP-M with 7794A AES-IntelliPro, and integrated onboard Local Annunciator plus MCT, Red Enclosure 2.0 ACCESSORIES Standalone AES-IntelliPro Fire full data module add -on accessory board with 7794A firmware for new IntelliNet 2.0 units only, cannot be used in legacy units 77-WiFi AES certified WiFi adapter 77-FACPA FACP Power Supply Adapter for internal mount 77-FACPA-KIT External installation hardware for 2-way Junction Box Legacy• •- 7706-ULF Integrated Fire Monitoring System, Red Enclosure Legacy Fire Subscriber, 8 Zone with 7795 AES-IntelliPro (7794 full data module, 7788F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones with 7794 AES-IntelliPro, 7788F-ULP Red Enclosure 7788F Legacy Fire Subscriber, 8 Zone, 8 Supervised Zones, Red Enclosure Legacy Fire Subscriber, 4 Zone with 7795 AES-IntelliPro (7794 full data module, 7744F-ULP-P 7762 hardware supervisory module, and 7740 Local Annunciator), Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Supervised Zones with 7794 AES-IntelliPro, 7744F-ULP Red Enclosure Legacy Fire Subscriber, 4x4 Zone, 4 Reversing Polarity, 4 Supervised Zones, 7744F Red Enclosure LEGACY ACCESSORIES 7794 Standalone AES-IntelliPro Fire full data module add -on accessory board for legacy units only, please see 7794A above for IntelliNet 2.0 version Technical Specifications 7707 Fire DIMENSIONS 13"H x 8.5"W x 4.5"D (33cmH x 21.5cmW x 11.4cmD) WEIGHT 5.8 Ibs (2.6 kilograms) excluding battery 13 Ibs (5.9 kilograms) with 10 Ah battery RADIO FREQUENCY Standard Frequency Range 450-470 MHz Contact AES for other UHF and VHF frequencies ANTENNA 2.5 dB tamper resistant antenna included, mounts on enclosure Optional remote mounting antenna available POWER INPUT AC SOURCES Transformer: Class 2 16.5V AC nominal output 1.9 A max current (40 VA MIN) ELK ELK-TRG1640, MG ELECTRONIC SALES MGT1640, or AES 1640 (not included) DC SOURCES (includes FACP) 24V DC Regulated Power Supply with Subscriber Rechargeable Battery 1.9 A max current BACKUP BATTERY 10-12 Ah, UL recognized lead acid gel cell, size based on subscriber configuration Contact Us ALARM SIGNAL INPUTS/ZONES 8 individually programmable E.O.L. type zone inputs 4+4: 4 reverse polarity input and 4 individually programmable E.O.L. type zone inputs Optional 7794A AES-IntelliPro for full data via Contact ID, Pulse, Modem Ile and Modem IIla2 UL LISTINGS UL 864 loth Edition Standard for Control Units and Accessories for Fire Alarm Systems ULC S559-04 1st Edition Equipment for Fire Signal Receiving Centres and Systems TROUBLE OUTPUT—ACK DELAY/ANTENNA CUT Form C relay, fail secure, rated 24V DC 1A resistive, unsupervised RESET BUTTON Located on main circuit board OPERATING TEMPERATURE 32 to 120OF (0 to 49°C) STORAGE TEMPERATURE 14 to 1400F (-10 to 60°C) RELATIVE HUMIDITY 0 to 93%, non -condensing RECHARGE CAPABILITY Will charge 12V battery size from 10-12 Ah PORTS Ethernet for configuration and message communication USB access for software upgrade REMOTE ANNUNCIATOR AES Model 7740 Remote Annunciator, supervised COMPATIBLE RECEIVERS 7705i AES-MultiNet Receiver CONFIGURATION INTERFACE Web browser capable device accessible via smartphone, tablet, laptop, or PC CURRENT CONSUMPTION Standby w/ charged backup battery: 200 mA (1.2 A Transmitting) Standby + charging backup battery: 900 mA (1.9 A Transmitting - MAX) POWER OUTPUT 2 or 5 Watts Factory set ENCLOSURE MATERIAL Steel with paint finish FINISH COLOR Red VISUAL INDICATORS Front panel LCD (2 x 20 alphanumeric character backlit display) Power and Trouble LEDs (ALM, Trouble, Tx, Rx, WA) For pricing and availability or to learn more about IntelliNet 2.0, please call your loca AES Sales Representative at (800) 237-6387 or email sales@aes-corp.com. E&z� of SECURITY CORPORATION INNOVATION TECHNICAL SPECIFICATIONS -Transmits full data to AES receiver using Contact ID or Pulse formats • Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile*, and Modem IIla2* 1/0 CONNECTIONS -AES subscriber with power • Handheld/PC programming port • POTS incoming phone line • Phone output from alarm panel -Trouble output (form C relay) SIZE 2.8 x 5.0 inches (7.1cm x 12.7cm) POWER REQUIREMENTS 12 VDC nominal, primary and backup power provided by the AES RF Transceiver Unit HOW TO ORDER Model Description 7794 AES-IntelliPro Fire 7744F-P UL Fire Subscriber w/7794 (4 reversing polarity & 4 EOL inputs) 7788F-P UL Fire Subscriber w/7794 (8 EOL inputs) Full Data Module 7794 AES-IntelliPro Fire' @LISTED Features -Commercial fire alarm applications - with or without phone lines -Transmits full alarm data from any Contact ID or Pulse format fire alarm panel -Supports expanded event reporting from Bosch Modem II and Modem III alarm panels • Primary or back-up communications -Universal wireless alarm transmitter supports most manufacturers' panels • Easy to install in AES subscriber • Easily programs using an AES Handheld Programmer or laptop -Option to remotely configure via a web browser -Option to monitor telephone lines -Transmits full data to AES receiver using Contact ID or Pulse formats •Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile*, and Modem IIla2* The 7794 AES-IntelliPro FireTM is an add -on module for AES subscribers that enables transmission of full alarm zone data from an alarm panel to a central station over an established AES-IntelliNet network. AES subscribers with AES-IntelliPro Fire can operate in applications with or without a phone line providing full emulation of the phone line for the alarm panel communicator. AES-IntelliPro Fire supports most popular alarm communication protocols including Contact ID and Pulse as well as Modem II and Modem III converted to CID. About AES Corporation Established in 1974, AES Corporation empowers companies to grow profitable alarm monitoring businesses, and government agencies to enhance security anywhere in the world. By providing the industry's only patented operator -owned and controlled private wireless mesh networks, AES ensures superior reliability, low TCO and optimal RMR while reducing dependence on service provider infrastructures. The company's flagship AES-(ntelliNet systems are deployed in over a half million locations worldwide. Easy Installation AES-IntelliPro Fire easily installs in the subscriber housing and is powered from the transceiver module, requiring no additional power connections. AES subscribers can be ordered with AES-IntelliPro Fire installed. AES-IntelliPro Fire is easy to program using the AES Handheld Programmer. =AEs /ntelliNet CORPORATION AES-IntelliNeC Private Wireless Mesh Network IP Link 0 Alarm Panel E20 .j-, Customer's Premise Central Station AES MultiNet Receiver 'ffiAES IP Link dw Alarm Automation 0RAT Hc SmartRescue Base Station 2500-205FM �W d. Part #: 2500-205FM Size: •Face: 16.11"Hx14"Wx3"D • Back Box: 15.62" H x 12" W x 3" D Style: • Powder coated steel enclosure • Flush mount • Twist lock closure for use with Fireman's lock (not provided) • Coil cord Features: • Use with up to 5 Call Boxes on the same telephone line • Run twisted and shielded 4 wire set from each Call Box to Base Station unit and one standard phone line to outside world • Requires a single analog (POTS, PBX, or central office phone line) or digital phone line. If used on a VoIP or cellular network, you must purchase a RATH@ 2100-VOIP2CS or 2100-GSMLC4 Gateway Device. • Easy to use push buttons • Passively monitor communications between Call Boxes and outside world via the LEDs: 1. Solid lit LED indicates there is an emergency call in progress 2. Slow blinking LED indicates there is a call on hold • Audible alert when Call Box initiates call, silenced when call is joined from Base Station • Includes relay contact that trips if any Call Box has been activated • The Base Station is able to: 1. Call into all or individual Call Boxes as needed 2. Join existing conversations between Call Boxes and outside world 3. Hang up and original conversation will continue 4. Terminate outside world so it is only talking to the Call Boxes or terminate the call with all parties entirely • Volume control handset meets ADA requirements • Designed for either 120vac or 24vdc power • 16.8V 1400mAH battery (part # RP7300109A) • Built-in battery backup recharges from 120vac or 24vdc power (allows for a minimum of 4 hours talk time upon loss of power) • Telephone Line Voltage: 24v-48v • Meets all IBC, ADAAG, and NFPA code requirements • 3 year warranty • Conforms to UL Standard 2017 for Attendant Monitored Signaling Devices • Complies with Section 6.4 of UL 60950-1 • ETL Listing Number: 5013373 THE USA ONN56W24720 N. Corporate Circle • Sussex, WI 53089 800-451-1460 • www.rathcommunications.com 3YEARADEIWARRANTY Intertek 05/20 RAT H 2500-205FM N N N N N »� h h y y I .r 15.62" FRONT VIEW INSIDE VIEW WITH FRONT PANEL OPENED Back View 09.08] Side View �12.00" [304.69] 1.50" [38.091 1.50" [38.091 3.00" [76.2] 83 \ e0.88" [e22.23] 2.007[S. .80] 1.00" [25.40] e0.25" [e6.35] 1.00" [25.421 CABINET BACK BOX 1.81" [46.041 6.00" [152.401 1.50" [37.971 .0.2 " 6.00" [152.401 SIDE VIEW THE USA ONN56W24720 N. Corporate Circle • Sussex, WI 53089 MADE800-451-1460 • www.rathcommunications.com 3YEARIWARRANTY Intertek 05/20 rl RAT H EMERGENCY EVACUATION ASSISTANCE Part #: 2100-956SSRC2 Code Comoliance: SmartRescue System Call Box 2100-956SSRC2 Dimensions: Face Plate: 10" H x 6-17/25" W Back Box: 9-7/8" H x 6-1/2" W x 3" D Cover: 9-3/4" H x 6-1 /2" W x 1-1 /4" D Mounting: Surface Mount Design: Stainless Steel Warranty: 2 Years • International Building Code (IBC) • National Fire Protection Association (NFPA) • ETL Listing Number: 5013373 • Conforms to UL Standard 2017 for Attendant Monitored Signaling Devices • Complies with Section 6.4 of UL 60950-1 Power Requirements: • 24vdc from part # 2500-PWR24U Programming Features: • Programmable with up to 5 emergency numbers • Recordable location message (18 seconds) • On -site keypad programming or remote programming Phone Caaabilities: • Requires analog telephone line (POTS, PBX, or central office line) • Phone checks every 24 hours for an active phone line, if one is not detected, phone will provide a relay trip • Automatic answer feature with audible ring • Touch Tone operation only (Touch Tone is an AT&T registered trademark) Additional Features: • Compatible with SmartRescue Base Station or Command Center for in -building rescue coordination • Built-in 10 phone consolidator feature allows you to install 10 Call Boxes and 1 Base Station on a single telephone line • Remote or on -site diagnostic test • Automatic dialer (31 digit programmable memory) • Built-in battery backup recharges from 24vdc power (allows for a minimum of 4 hours of talk time upon power loss) • 7.2V 300mAH battery (part # RP7300110) Optional Feature: • Strobe interface and relay ONN56 W24720 N. Corporate Circle • Sussex, WI 53089 Intertek 800-451-1460 • www.rathcommunications.com 06/22 RAT H 2100-956SSRC2 6.GT [105.42] 10.0W 9.13" [79.31] O W.50^ [01270] s zs^ [ez 5s] 3.00" [7G20] 2 u^ [53.50] ..I 11 l N.50"101270] 0" EIS [35 101 sa Side View C s t t Back View CLEAR PROTECTIVE COVER - 425- [107.Bs] s.w^ [R2[ BACK BOX BOTTOM O BACK BOX FRONT BACK BOX LEFT SIDE BACK BOX RIGHT SIDE N56 W24720 N. Corporate Circle • Sussex, WI 53089 800-451-1460 • www.rathcommunications.com Top View