APPROVED FIR2023-0069+Drawings+7.31.2023_1.06.20_PM+3698132tl. ANSUL: 14"DIA DUCT ECONNECTION TO ALL ELECTRIC UNDER THE E5 HOOD, SHUTS DOWN UPON SYSTEM DISCHARGE 15"-0" (CONNECTION BY OTHERS) 14"DIA CONNECTION TO SUPPLY AIR, SHUTS DOWN UPON DUCT Mu SYSTEM DISCHARGE (CONNECTION BY OTHERS) ' INLINE BURST DISK 1W i i 3 0 rjjM_6rd 3 0 3 0 3rl (2) 3 GALLON TANKS I REGULATED RELEASE i i I N DOUBLE TANK CARTRIDGE ------------------------------------------- ------------- 1N 15"-40" -------------------------- 1F 1F 1F 40"-48" 00 (30 00 TiN 35"-40' o 0 0 0 3N7 25"-35" $ 0° 40" DOUBLE OVEN 21" 24"x24" STEAMER CHAR BROILER 36"x24" RANGE 24"x24" 14"x14" GRIDDLE FRYER NOZZLE SUMMARY TABLE HAZARD QTY NOZZLE PTS TOTAL CHARBROILER 1 1N 1 1 RANGE 3 1F 1 3 GRIDDLE 1 1N 1 1 FRYER 1 3N 3 3 PLENUM 2 1N 1 2 DUCT 2 1W 1 2 TOTAL 12 SYSTEM PIPING LIMITATIONS 6 GALLON (MANIFOLDED) REQUIREMENTS SUPPLY DUCT BRANCH PLENUM BRANCH APPLIANCE BRANCH PIPE SIZE 3/8" 3/8" 3/8" 3/8" MAXIMUM LENGTH 32 FT 8 FT 4 FT 12 FT MAXIMUM RISE 6 FT 4 FT 2 FT 2 FT MAX 90 ELBOWS 8 4 4 6 MAX TEES 2 2 2 4 MAX FLOW POINTS 22 4 2 4 08-09-2023 PLAN REVIEW APPROVED WITH CONDITIONS: 1. SYSTEM SHALL BE INTERCONNECTED TO FIRE ALARM SYSTEM. DFM BURT Approved DFM ChrfsSurt South County Fire Date: 08/09/2023 J MECHANICAL GAS SHUT OFF VALVE INSTALLED BEFORE FIRST APPLIANCE BY OTHERS FUSIBLE LINK TEMPERATURE SELECTION SHALL BE PER THE ANSUL INSTALLATION MANUAL RECOMMENDATIONS "8" - 42"i48" REMOTE PULL STATION SHALL BE LOCATED IN AN UNOBSTRUCTED LOCATION BETWEEN 42" AND 48" ABOVE THE FINISHED FLOOR (AFF) IN THE PATH OF EGRESS, OR AT A LOCATION ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. CLASS K WET CHEMICAL EXTINGUISHER SHALL BE INSTALLED NO MORE THAN 60" ABOVE THE FINISHED FLOOR WITHIN 30 FT FROM THE HAZARD. FI R2023-0069 ANSUL R102 6-GALLON MANIFOLDED SYSTEM USES 12 of 22 FLOW POINTS PRE-ENGINEERED SHOP DRAWING ONLY - NOT TO SCALE F I R2023-0069 PARTIAL FLOOR PLAN NOT TO SCALE 1. WORK DOES NOT INCLUDE ANY INSPECTION, REPAIR OR MODIFICATION TO THE HOOD OR DUCT SHEET METAL. PYE- BARKER FIRE & SAFETY RECOMMENDS AN INSPECTION OF THE HOOD AND DUCT BE PERFORMED BY QUALIFIED PERSONNEL PRIOR TO FIRE SYSTEM INSTALLATION. 2. ALL ELECTRICAL EQUIPMENT UNDER HOOD MUST SHUT DOWN ON SYSTEM ACTIVATION WHERE REQUIRED BY NFPA 96 STANDARDS (BY ELECTRICAL CONTRACTOR) 3. EXHAUST FAN MUST REMAIN RUNNING UPON SYSTEM ACTIVATION MAKEUP AIR FAN SHALL SHUTDOWN UPON SYSTEM ACTIVATION (BY ELECTRICAL CONTRACTOR) 4. MANUAL RELEASE STATION MUST BE PLACED AT A POINT OF EGRESS FROM THE COOKING AREA 5. ALL COOKING APPLIANCES SHALL BE EQUIPPED WITH WHEEL CHOCKS / SAFETY SETS TO ENSURE THEY ARE RETURNED TO THEIR ORIGINAL LOCATION ANYTIME THEY ARE REMOVED FOR CLEANING OR OTHER PROCESS. 6. K CLASS FIRE EXTINGUISHER SHALL BE PLACED IN WITHIN 30' OF HAZARD AREA, K CLASS EXTINGUISHER SHALL BE COMPATIBLE WITH FIRE SYSTEM WET AGENT. ALL PENETRATIONS TO THE HOOD AND/OR DUCT SHALL BE SEALED WITH AN UL LISTED & APPROVED QUICK SEAL DEVICE GASKET LOCK \ WASHER \` GASKET LOCK COMPRESSION / WASHER NUT NUT ADAPTOR / GASKET NUT SEAL �— ADAPTOR / In I BODY i P PIPE PIPE PIPE DUCT DUCT MICROSWITCH DIAGRAM COMMON (RED) O N.O. (BLACK) 21A 125/250 VAC 2 HP 250 VAC 1 HP 125 VAC N.C. (BROWN) 0 FIR20 3-00691 GENERAL NOTES: 1.SYSTEM SHALL BE PRE-ENGINEERED 2.SYSTEM SHALL BE MANUFACTURED BY ANSUL INC. 3.ANSUL R102 SYSTEMS HAVE THE FOLLOWING LISTINGS AND APPROVALS: UNDERWRITERS LABORATORIES INC, UL 300 / UL 1254, UL EX 3470 4.SYSTEM TEMPERATURE LIMITATIONS 32F MIN / 120F MAX 5.INSTALLATION REQUIREMENTS, NOZZLE LIMITATIONS AND DESIGN CRITERIA SHALL COMPLY WITH THE ANSUL R102 MANUAL AND ALL ADDENDUMS AS PUBLISHED BY ANSUL 6.PIPE AND FITTINGS SHALL BE SCHEDULE 40 BLACK, CHROME PLATED OR STAINLESS. GALVANIZED PIPE SHALL NOT BE USED. 7.ALL REQUIRED ELECTRICAL WORK SHALL BE PERFORMED BY OTHERS AND IS NOT INCLUDED ON THIS SHOP DRAWING. 8.ALL REQUIRED PLUMBING WORK BE PERFORMED BY OTHERS AND IS NOT INCLUDED ON THIS SHOP DRAWING General Piping Requirements 1. All R-102 system piping is straight line. Therefore, the need for critical lengths and balancing is minimized. 2 Two 45' elbows count as one 900 elbow. 3. Each branch line includes the tee or elbow leading to it, and all fittings within the branch line itself. 4. The minimum piping length of Schedule 40, 3/8 in. pipe from the tank outlet to any nozzle protecting a range, fryer, or wok must be 6 ft. (1.8 m). 5. Pipe lengths are measured from center of fitting to center of fitting. See Figure 85. CENTER TO CENTER 000778 6. All distribution piping must be 3/8 in. Schedule 40 black iron, chrome -plated, or stainless steel. Do not use hot dipped gal- vanized pipe on the distribution piping. 7. All threaded connections located in and above the protected area must be sealed with pipe tape. Tape should be applied to male threads only. Make certain tape does not extend over the end of the thread, as this could cause possible blockage of the agent distribution. 8. Before installing blow -off caps on nozzles, apply a small amount of Dow Corning No. 111 silicone grease across the opeing in the nozzle tip and also a small amount coating the exterior of the blow -off cap. This will help keep cooking grease from building up on the cap. 9. Tees used in the distribution piping can be used as thru tees, side outlet tees, or bull tees. TO NOZZLES TO PULL STATION (MOUNT TO CODE) '0 DETECTORS TO GAS VALVE 6 GAL. MANIFOLDED SYSTEM DETAIL N.T.S. F I R2023-00691 FIGURE 85 X0778 Distribution Piping Requirements — 6.0 Gallon Manifolded System (Continued) This configuration consists of two 3 gallon tanks. Both tanks are connected to a common manifold tee and are pressurized from a single double tank (Part No. 73022) nitrogen cartridge in the regu- ► fated release assembly. See Figure 115. Note: A tank mounting bracket can be utilized instead of the tank/enclosure assembly. See Figure 117. USE HOSE/ GROMMET PACKAGE (PART NO. 418511) 3.0 GALLON TANK 3/8 IN. SUPPLY SEE NOTE NO. 1 3.0 GALLON TANK 3/8 IN. 3/8 IN BRANCH SUPPLY 318 IN BRANCH IN -LINE BURST DISC ASSEMBLY — SEE NOTE NO. 4 3.0 GALLON REGULATED RELEASE 008127 ASSEMBLY OR 3.0 GALLON REGULATED ACTUATOR ASSEMBLY TANKIENCLOSURE ASSEMBLY REMOVE BURST DISC — SEE NOTE NO. 3 DOUBLE TANK NITROGEN CARTRIDGE OR (LT-A-101-30 CARTRIDGE — REGULATED ACTUATOR ONLY) NOTE 1 : THE PIPE CONNECTION FROM TANK CENTER TO TANK CENTER CANNOT EXCEED 8-1/2 IN. (21.5 cm). ALSO, OEM RELEASE/BRACKET ASSEMBLY CAN BE UTILIZED WHEN MANIFOLDING 3.0 GALLON TANK. NOTE 2: ONLY 3 GALLON TANKS CAN BE MANIFOLDED. NOTE 3: THE BURST DISC THAT IS PART OF THE TANK ADAPTOR/BURST DISC ASSEMBLY MUST BE REMOVED AND MODIFIED. SEPARATE THE ALUMINUM DISC MATERIAL FROM THE PLASTIC GASKET. DISCARD THE ALUMINUM DISC MATERIAL AND REINSTALL THE PLASTIC GASKET BACK INTO THE TANK ADAPTOR/BURST DISC ASSEMBLY. NOTE 4: THE IN -LINE BURST DISC ASSEMBLY, PART NO. 416790, IS TO BE MOUNTED AS CLOSE TO THE TANK OUTLET AS POSSIBLE. AFTER SYSTEM DISCHARGE, THE ASSEMBLY MUST BE DISASSEMBLED AND A NEW BURST DISC INSTALLED. FIGURE 115 IN -LINE BURST DISC ASSEMBLY (MANIFOLDED SYSTEMS ONLY) The in -line burst disc assembly is required to eliminate the siphoning of the agent up the pipe during extreme temperature variations. In addition to eliminating the siphoning effect, the common in -line burst disc assembly eliminates the possibility of one or more individual discs located in the tank adaptor from failing to burst. The assembly consists of a stainless steel body which houses the burst disc. When utilizing this assembly in a manifolded system, it is necessary to modify (remove) the burst disc located in all of the R-102 tank adaptors in the system. The in -line burst disc assembly is to be mounted as close to the tank outlet as possible. After system discharge, the assembly must be disassembled and a new burst disc installed. Part No. Description 416970 In -Line Burst Disc Assembly 417911 Burst Disc (Pack of 10) RED SIDE OF Bi DISC TO BE TOb_11— ADAPTOR (PART NO. 417707) —I (39mm) FIGURE 3-34 008383 F I R2023-0069 DUCT PROTECT] 2-8 IN_ (5 — 20 cm) DUCT SIZES UP TO 50 IN. (127 cm) PERIMETER/ 16 IN. (41 cm) DIAMETER • One 1 W nozzle (Part No. 419336) = one flow number • 50 in. (127 cm) perimeter maximum • 16 in. (41 cm) diameter maximum DUCT SIZES UP TO 100 IN. (254 cm) PERIMETER/ 32 IN. (81.3 cm) DIAMETER • One 2W Nozzle (Part No. 419337) = two flow numbers • 100 in. (254 cm) perimeter maximum 32 in. (81.3 cm) diameter maximum The chart below shows the maximum protection available from each duct nozzle. Part Description No. 2W Nozzle 419337 1 W Nozzle 419336 3.0 Gallon System Maximum 100 in. (254 cm) Perimeter Maximum 50 in. (127 cm) Perimeter 1.5 Gallon System Maximum 100 in. (254 cm) Perimeter Maximum 50 in. (127 cm) Perimeter HORIZONTAL PROTECTION — OPTION 1 1 N NOZZLE — PART NO. 419335 — SINGLE BANK PROTEC- TION One 1 N nozzle will protect 10 linear feet (3.1 m) of single filter bank plenum. The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length. The nozzle must be positioned 0-6 in. (0-15 cm) from the end of the hood to the tip of the nozzle. See Figure 9. LM Gas-Radiant/Electric Char -Broiler Protection The R-102 system uses the 1 N nozzle, (Part No. 419335) for gas- radiant/electric char -broiler protection. The nozzle tip on the 1 N nozzle is stamped with a 1 N, indicating that this is a one -flow nozzle and must be counted as one flow number. One IN nozzle will protect a hazard with a maximum length of 36 in. (91 cm) and a total cooking area which does not exceed ► 864 in.2 (5574 Cm2). The nozzle tip must be located 15 to 40 in. (38 to 102 cm) above the hazard surface. When using this nozzle for gas-radiant/electric char -broiler protection, the nozzle must be positioned anywhere along or within the perimeter of the maximum cooking area and shall be aimed at the center of the ► cooking surface. See Figure 59. COOKING AREA COOKING AREA 000256 I � t i I 40 IN. (102 cm) i I MAXIMUM I� 15 IN. (38 cm) ` MINIMUM I 000257 ► FIGURE 59 Range Protection 1F (1-Flow) Nozzle (With or Without Back Shelf/Obstruction) Single and multiple burner ranges can be protected using a ► 1 F nozzle. The nozzle is stamped with 1 F indicating that it is a one -flow nozzle and must be counted as one flow number. When using the 1 F nozzle for range protection with or without back shelf or other similarly sized obstruction, the maximum length of the burner grates being protected must not exceed 28 in. (711 mm) and the maximum area of the burner grates must not exceed 336 in.2 (21677 mm2). See Figure 4-37 for nozzle location details. 1 F NOZZLE SHELF OR OTHER SIMILARLY SIZED OBSTRUCTION CAN OVERHANG BURNER(S) BY A MAXIMUM OF 11 IN. (279 mm) � 1 1 18 IN. AIM (457 mm) 40 - 48 IN. I POINT MINIMUM (1016 - 1219 mm) 1 II 14 1 (355 mm) 12IN. 14IN. MAXIMUM (304 mm) FRONT TO REAR (355 mm) MAXIMUM MAXIMUM CENTERLINE 1 F NOZZLE LOCATED OVER FRONT EDGE OF BURNER GRATE AND ORIENTED SO NOZZLE TIP FLATS ARE PARALLEL WITH BURNER GRATE FRONT TO REAR CENTERLINE AND SHALL BE AIMED AT THE CENTER OF THE COOKING SURFACE. FI R2023-00691 Griddle Protection 1 N (1-Flow) Nozzle — High Proximity Application The R-T 02 system uses four different nozzles for the protection of griddles. One of the applications requires a 1-flow nozzle and three of the applications require a 2-flow nozzle. High Proximity Application: 35 in. to 40 in. (89 to 102 cm) above the cooking surface. This high proximity application uses the 1 N nozzle, Part No. 419335. The nozzle tip is stamped with 1 N indicating this is a one -flow noz- zle and must be counted as one flow number. One 1N nozzle will protect a maximum cooking area of 1080 in.2 (6968 cm2) with the maximum longest side of 36 in. (91 cm). When using this nozzle for griddle protection, the nozzle must be positioned along the cooking surface perimeter to a maximum of 2 in. (5 cm) inside the perimeter, and aimed to the midpoint of the cooking surface. See Figure 39 and 40. NOTICE When using this type of griddle protection, only 5 flow numbers are allowed on a 1.5 gal (5.7 L) system and only 11 flow numbers are allowed on a 3 gal (11.4 L) system. r MIDPOINT OF COOKING SURFACE I I I I 7N NOZZLE LOCATED ALONG ANY SIDE OF GRIDDLE SURFACE WITHIN O — 2 IN. (O — 5 cm) OF COOKING SURFACE EDGE. NOZZLE MUST BE AIMED AT MIDPOINT OF COOKING SURFACE. GE FIGURE 39 000�+i I I NOZZLE LOCATION 1 I O-2IN. (0-5 cm) I ' I I INSIDE PERIMETER yl If OF COOKING SURFACE 40 IN. I I (102 cm) MAXIMUM H IE 1 N OF 1 I I NOZZLE TIP II I Ir 35 IN. cm) MINIMUMUM I MINIMUM 1 1 EDGE 1 I I HEIGHT I I OF I I COOKING 1 1 N -Z I I NOZZLE TIP I SURFACE I 1 I FIGURE 40 FRYER PROTECTION Fryer — Single Nozzle Protection 1. Design requirements for fryers are broken down into two types. A. FRYERS WITHOUT DRIPBOARDS If the fryer does not include a dripboard, measure the internal depth (horizontal dimension from front to back) and length of the frypot. B. FRYERS WITH DRIPBOARDS If the fryer includes any dripboard areas, measure both the internal depth (horizontal dimension from front to back) and length of the frypot portion, and then measure the internal depth and length of the overall hazard area including any dripboard areas. I II I I I I i I II I I I I l ll I I I 1 I I II I I 1 1 1 I li i TOP OF FRYER i 1 I I I l I i y 1 FRYER WITHOUT DRIPBOARD FRYER WITH DRIPBOARD NOZZLE TIP POSITIONED ANYWHERE ALONG OR WITHIN PERIMETER OF COOKING SURFACE AND AIMED TO THE CENTER OF THE COOKING AREA. Max. Size Max. Size Overall Type of Nozzle Height Frypot Only With Dripboard Nozzle Above Top of Fryer 18 in. x 18 in. 18 in, x 27 314 in, 3N 25 in, to 35 in. ► (457 mm x 457 mm) (457 mm x 704 mm) (635 mm to 889 mm) FI R2023-00691 SYSTEM SHALL UTILIZE GLOBE ML°TM FUSIBLE LINKS FOR AUTOMATIC SYSTEM ACTIVATION. FUSIBLE LINKS ARE DESIGNED TO SEPARATE AT SPECIFIC TEMPERATURES, RELEASING TENSION FROM THE FUSIBLE LINK DETECTION LINE AND CAUSING SYSTEM ACTUATION. CORRECT FUSIBLE LINK SELECTION IS AN ESSENTIAL ELEMENT IN THE DESIGN OF ANY FIRE SUPPRESSION SYSTEM. AFTER PERFORMING A TEMPERATURE STUDY TO DETERMINE THE MAXIMUM AMBIENT TEMPERATURE AT THE FUSIBLE LINK LOCATION, THE CORRECT FUSIBLE LINK SHOULD BE SELECTED FROM THE FOLLOWING CHART: TEMPERATURE RATING MAX AMBIENT TEMPERATURE LOAD RATING OF °C OF °C MIN MAX 1350 570 1000 380 10 LBS 40 LBS 1650 740 1000 380 10 LBS 40 LBS 2120 1000 1500 660 10 LBS 40 LBS 2 25„ 2800 1380 2250 1070 10 LBS 40 LBS GLOBE® 3600 1820 3000 1490 10 LBS 40 LBS ML?@i 0 4500 2320 3750 1910 10 LBS 40 LBS Made in USA 5000 2600 4300 2170 10 LBS 40 LBS • UL LISTED TO UL 33, HEAT RESPONSIVE LINKS FOR FIRE PROTECTION SERVICE • DATE STAMPED WITH YEAR OF MANUFACTURE .66" 79" • CORROSION RESISTANT CONSTRUCTION • STAINLESS STEEL COMPONENTS • FLEXIBLE EYE HOOK CONNECTION • 21/64" MOUNTING HOLE DIAMETER • LISTED FOR USE IN ALL FIRE PROTECTION SYSTEMS GLOBE ML°TM FUSIBLE LINK DETECTOR TYPICAL DETAIL FI R2023-00691