APPROVED RESUB 1 BLD2023-0287+Structural_Plan+8.17.2023_2.19.51_PM+3732676CITY OF EDMONDS
BUILDING DIVISION
SHEARWALL SCHEDULE
SWEXP
Notes apply as called out in table below.
1 Anchor bolts embedded at least 7", or 1/2"0 *Titen-HD w/ 4" min embed. See detail SWB.
2 #MASAP can be installed instead of sill bolts with washers. When replacing 1/2"0 sill bolts use 7-10dx11/2"
nails (minimum nailing) and when replacing 5/8"0 sill bolts use 9-10dx11/2" nails (maximum nailing).
3 See detail SWF. Connections vary depending on condition. 3a May substitute 16d toe nails @ 8"oc for #A35.
4 See detail SWR. For gable -end roof connections see detail SWF.
5 See detail SWB.
6 Abutting panel edges require a 2-2x (lamination connection same as WALL BASE PLATE), 3x, or greater stud.
7 See detail DSW.
8 The plate washer shall extend to within 1/2" of the edge of the bottom plate that receives the sheathing or rim.
At double -sided shearwalls, stagger on both plate edges.
SHEAR FLOW CONNECTIONS / SPACING
S
SILL -TO -
FLOOR -TO -
ROOF -TO -
WALL BASE PLATE
CALL
FOUNDATION 1, 2
SILL &WALL
WALL 4
5
OUT
5/8"0 @ 60"oc or
*A35 @
#H1 @
16d @ 10"oc
A
1/2 "0 @ 60"oc
32"oc 3a
24"oc
5/8"0 @ 60"oc or
*A35 @
#LS50 @
16d @ 6"oc
B
1/2"0 @ 40"oc
24„ oc
32 oc
5/8"0 @ 32"oc or
*A35 @
#LS50 @
16d @ 4"oc
1/2"0 @ 24"oc 8
16"oc
16"oc
5/8"0 @ 24"oc or
*A35 @
#LS50 @
16d @ 3"oc
D
1/2"0 @ 16"oc 8
12"oc
12"oc
5/8"0 @ 16"oc or
*A35 @
#LS50 @
2-16d @ 3"oc to 4x
C
G
1/2"0 @ 12"oc 8
8"oc
8"oc
rim/blkg
5/8"0 @ 9"oc or
*HGA10KT
N/A
0.22" x 4" #SDWS
C
r
1/2"0 @ 6"oc 8
@ 5"oc
@ 3"oc to 4x rim
HOLDOWN SCHEDULE
R►
WALL SHEATHING
CALL
OUT
SHEATHING
THICKNESS
EDGE
NAILS
16
7/16"
8d @ 6"oc
4
7/16"
8d @ 4"oc
3
7116" 6
8d @ 3"oc
2
7116" 6
8d @ 2"oc
33
7/16" both
sides 6, 7
8d @ 3"oc
1 Deepen the foundation as needed to provide the required holdown embedment into the foundation wall.
See Detail MHE
2 Fasten to the end framing members of the shearwall, u.n.o.
3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required.
4 Provide the minimum embedment and edge distances specified by the manufacturer.
5 Attach to (2) 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails), u.n.o.
6 See detail HDN for installation.
HOLDOWN / STRAP
IL, 2,4,6
FASTENERS 5
FOUNDATION
ANCHOR 1,3,4,6
COMMENTS
#STHD14/14RJ
30-10d common
N/A
8" Stem
*HTT5
26-10d common
#SSTB16
2-2x4 Min Post U.N.O.
#HTT5KT
26 - #SD #10x21/2-
#SB5/8"x24
2-2x4 Min Post U.N.O.
#HDU11-SDS2.5
30 - :#SDS1/4x21/2
1 T.R.
6x6 Min Post, See detail RFA
*HDU14-SDS2.5
36 - #SDS1/4x21/2
1 T.R.
6x6 Min Post, See detail RFA
*CS16
22-10d common
N/A
13" Min End Length, See detail CSH
#MSTC66
68-10d common
N/A
equal number of nails to both connected
elements
(2) * MST 60
46-16d common
N/A
equal number of fasteners to both
connected elements. 6x6 Min Post
The following documentation shall be available on '
site for the building inspector: •
■ 1
■
1771 r.nF APPRn\/Fn ARC;HITFC;TI 1RA1 PI AN RFT
■ 1
❑ COE APPROVED STRUCTURAL PLAN SET '
n
1
COE REVIEWED CALCULATION PACKET 1
■
❑ ENERGY CREDIT WORKSHEET '■
■ 1
❑ SITE PLAN
■
n
1
CIVIL PLAN i
■ ❑ 1
1
❑ ■
■ 1
1
■ CITY OF EDMONDS BUILDING DEPARTMENT 2021
GENERAL STRUCTURAL NOTES
CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or
other codes required by the governing jurisdiction.
PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve
the integrity of the structure throughout it's lifetime.
INSPECTIONS Notify Building Department for inspections required by local jurisdiction.
SOILS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed
level soil devoid of any organic material and below indicated frost line.
COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and
debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent
of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures.
BACKFILL shall be free draining and without organic material and debris from one of the following soil
classes SM-SC, SM, SP, SW, GC, GM, GP, and GW.
FOUNDATIONS AND RETAINING WALLS Extend footings to undisturbed bearing soil. Do not backfill until all
slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement.
There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds
the wall height.
SILL PLATES Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors
4"). Use 3"x3"0.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6
feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece.
CONCRETE fc = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or
unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum
of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be
prevented through proper handling and placement.
REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be
Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded
wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices.
See applicable detail(s): BD SH
CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o.
See applicable detail(s): RI
FOOTING DRAINAGE Footing drainage per Building Code section 1805.4.2 & Residential Code section
R405.1.
WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated.
Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations.
CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact
with pressure treated wood shall be hot -dipped zinc -coated galvanized.
EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate
preservative treated wood in an interior, dry environment shall be permitted.
SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING
RULES FOR WESTERN LUMBER", latest edition:
BEAMS, POSTS, RA FTERS, JOIST
6X and wider DF#1
4X DF#2
2x 10 and greater DF#2
2x 8 and smaller HF#2
WALL STUDS
2x HF#2
ENGINEERED WOOD shall meet the following minimum properties:
Callout E x 106 (psi) Fb(psi) Fc par (psi) Fc perp (psi) Fv(psi)
GLB 1.8E 2400 1650 650 240
All cantilevered and multi -span glue -laminated beams (GLB) shall be V8 unless noted otherwise,
additionally cantilevered beams shall have zero camber.
24F-V4 shall be cambered with a 3500' radius u.n.o.
LVL 2.0E 3100 3000 750 285
LSL 1.55E 1900 2050 900 310
PSL 2.2E 2900 2900 625 290
Engineered wood products shall be protected from moisture to preserve their structural integrity.
Provide temporary bracing to avoid permanent deflections resulting from drying under construction
dead loads.
I -JOISTS Connect I -joist to plate using one 10d (0.131" x 3") nail on each side of bottom flange; drive nails
at an agle at least 1 1/2" from end. Connect 1 1/4" LSL rim to I -joists with one 10d (0.131" x 3") nail into
top and bottom flange. Full -depth blocking between joists over shearwalls shall be 1 1/4" min LSL.
TRUSSES Manufactured trusses are a deferred submittal item designed per CODE section 2303.4 and shall
be designed for all loads and load combinations per the CODE All connections per manufacturer, u.n.o.
If truss layout is changed by manufacturer, please notify this office. For trusses over walls, if header is not
specified over openings, design truss to span over it.
See applicable detail(s): GEB
WALL FRAMING & BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base
plate (exterior walls shall be 2x6 u.n.o. & interior walls shall be 2x4 u.n.o.).
Block all supports solid to the foundation.
See applicable detail(s): BHS TPS
BEAM PENETRATIONS Allowable beam penetrations shall be made in the middle third of the span and the
middle third of the depth. Contact this office for any penetration outside the allowable area.
See applicable detail(s): BP POF
GENERAL STRUCTURAL NOTES continued
WOOD STRUCTURAL PANELS shall meet the performance standards of the "APA" DOC PS1 and PS2 for their
intended application (group 5 species not allowed).
SHEARWALLS are indicated on the plans with a bold dashed line and labeled SW. The following letter
designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS / SPACING table, and the
number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number
designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding
engineering calculations.
Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See
Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs
shear values). All panel edges shall be blocked. Nail intermediate supports @ 12"oc. Do not penetrate
nails past flush. Install squash blocks under the ends of all shearwalls where the framing below does not
provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the
shearwall below.
Rated sheathing:
7/16" OSB rated with a 24/16 span rating.
1/2" CD with a 32/16 span rating.
See applicable detail(s): SWE
ROOF DIAPHRAGM Install either OSB or CD sheathing:
7/16" OSB rated sheathing with a 24/16 span rating;
panel clips required when spacing is greater than 20" oc.
1/2" CD rated sheathing with a 32/16 span rating.
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows
half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with
8d @ 12"oc, blocking not required u.n.o.
ROOF -TOP DECK DIAPHRAGM Install minimum
23/32" rated Sturd-I-Floor T&G with a 24oc span rating
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half
the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior
supports with 10d @ 12" oc, blocking not required u.n.o.
FLOOR DIAPHRAGM Install minimum
23/32" rated Sturd-I-Floor T&G with a 24oc span rating.
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half
the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior
supports with 10d @ 12" oc, blocking not required u.n.o.
GARAGE FLOOR DIAPHRAGM Install minimum
1 1/8" rated Sturd-I-Floor T&G with a 16oc panel index
Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half
the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior
Top with a min of 3" concrete reinforced with 6" x 6" 10/10 wire mesh.
COLLECTORS Diaphragms shall be nailed continuously to rims, drag struts, drag trusses and other collector
elements at boundary spacing, u.n.o.
See applicable detail(s): DTC CS
CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, "*", indicates a hardware
connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities
from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an
equivilent or greater capacity selection. Install per the manufacturer instructions.
Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized.
NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification
for Wood Construction (NDS) u.n.o.
HOLDOWNS See the HOLDOWN SCHEDULE.
See applicable detail(s): HDN HOC
POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s)
U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam.
HANGERS Model numbers will be specified on the plans for conditions that require more than minimum
capacity, otherwise see CONNECTIONS. When a hanger is not specified on the plans, use any size specific
model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or
shimming of beam not allowed unless specified.
JOBSITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design
and/or construction review services related to the contractor's safety precautions or to means, methods,
techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site
visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible
for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their
employees, or for access, visits, use work, travel, or occupancy by any person.
OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural
Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound
Structural Solutions Inc.
MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall
provide temporary bracing as required until all permanent connections and stiffenings have been installed.
Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations.
Basic Wind Speed (3 sec gust) mph 98
Surface Roughness B
Wind Exposure Category C
APPROVED PLAN
PLAN INSTRUCTIONS
READ THIS FIRST
These plans are organized so that more detailed or specific information is found in the same
way by following the direction shown below:
GENERAL STRUCTURAL NOTES
SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more
specific information.
SCHEDULES
DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more
specific information.
DETAILS
PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more
specific information.
PLANS
See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional
information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note,
indicates that the information specified shall apply in all similar conditions.
IF YOU HA VEA NY QUESTIONS OR CONCERNS CONTA CT US IMMEDIA TEL Y!
We can be reached immediately by phone: (425) 778-1023
For less pressing questions, email us: inbox@ssseng.com
Please help us get to your plans by having this job number handy: s2209020
ABBREVIATIONS AND ACRONYMS
ABV ABOVE E.S. EACH SIDE O.C. ON CENTER
A. B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED
BLW BELOW EA EACH REINF REINFORCEMENT
BLK BLOCK E.N. EDGE NAILING REQD REQUIRED
BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE
B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR
BTM BOTTOM FDN FOUNDATION STD STANDARD
BRIG BEARING FLR FLOOR STRUCT STRUCTURAL
BTWN BETWEEN FRMG FRAMING SW SHEARWALL
CLR CLEAR FTG FOOTING THRU THROUGH
CLTR COLLECTOR G.T. GIRDER TRUSS T.R. THREADED ROD
CONC CONCRETE GR GRADE TYP TYPICAL
CONN CONNECTION HORIZ HORIZONTAL U.N.O. UNLESS NOTED
CONT CONTINUOUS MAX MAXIMUM OTHERWISE
CTR CENTER MFG MANUFACTURED VERT VERTICAL
DBL DOUBLE MIN MINIMUM w/ WITH
DET DETAIL o/ OVER w/o WITHOUT
E.E. EACH END oc ON CENTER W.W.F. WELDED WIRE FABRIC
DESIGN CRITERIA
Governing Code 18 IBC Risk Category II
Wind Design Data
Earthquake Design Data
Gravity Load Data
loads are psf
Dead Live Snow
Rafters'-
•Solar-Ready3 20 0 25
Trusses (pitched)
*Pitches :5 8:12
*Solar-Ready3
Pitches:5 8:12
Top Chord 15 0 25
Bottom Chord 5 0 0
Floors: loads are psf
Dead Live Snow
Joistss 12 40 0
Garage Floor 90 40 0
Decks: loads are psf
Dead Live Snow
Joistss 50 60 25
Notes apply as called out in table above.
1 Rafters of sawn lumber or wood I -joists.
3 Dead load includes 5psf for photovoltaic panels.
5 Joists of sawn lumber or wood I -joists.
Soil Data
Company: Cobalt Geosciences Date: 9/17/20
*Includes F.S. = 1.5 per Geotech Report
Seismic Importance Factor, Ie 1.00
Site Classification D
Short Period Acceleration, SS 1.296
1-Second Acceleration, S1 0.458
Seismic Design Category D
Spectral Response Coefficient, SIDS 0.864
Spectral Response Coefficient, Spl 0.562
Allowable Soil Bearing 2000 psf
Passive Earth Pressure 275 *pcf
oo
Seismic Force Resisting System Table 12.2-1: A-15
2016 Equiv. Lateral Force Procedure
Response Modification Factor, R 6.5 Transverse
6.5 Longitudinal
Seismic Response Coefficient, CS 0.133 Transverse
0.133 Longitudinal
Seismic Base Shear, V 29267 Ibs
Active Soil Pressure 35 pcf
Coefficient of Friction 0.40
At -Rest Soil Pressure 55 pcf
Unit Weight of Soil 125 pcf
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
APPROVED PLAN
PLAN INSTRUCTIONS
READ THIS FIRST
These plans are organized so that more detailed or specific information is found in the same
way by following the direction shown below:
GENERAL STRUCTURAL NOTES
SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more
specific information.
SCHEDULES
DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more
specific information.
DETAILS
PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more
specific information.
PLANS
See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional
information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note,
indicates that the information specified shall apply in all similar conditions.
IF YOU HA VEA NY QUESTIONS OR CONCERNS CONTA CT US IMMEDIA TEL Y!
We can be reached immediately by phone: (425) 778-1023
For less pressing questions, email us: inbox@ssseng.com
Please help us get to your plans by having this job number handy: s2209020
ABBREVIATIONS AND ACRONYMS
ABV ABOVE E.S. EACH SIDE O.C. ON CENTER
A. B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED
BLW BELOW EA EACH REINF REINFORCEMENT
BLK BLOCK E.N. EDGE NAILING REQD REQUIRED
BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE
B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR
BTM BOTTOM FDN FOUNDATION STD STANDARD
BRIG BEARING FLR FLOOR STRUCT STRUCTURAL
BTWN BETWEEN FRMG FRAMING SW SHEARWALL
CLR CLEAR FTG FOOTING THRU THROUGH
CLTR COLLECTOR G.T. GIRDER TRUSS T.R. THREADED ROD
CONC CONCRETE GR GRADE TYP TYPICAL
CONN CONNECTION HORIZ HORIZONTAL U.N.O. UNLESS NOTED
CONT CONTINUOUS MAX MAXIMUM OTHERWISE
CTR CENTER MFG MANUFACTURED VERT VERTICAL
DBL DOUBLE MIN MINIMUM w/ WITH
DET DETAIL o/ OVER w/o WITHOUT
E.E. EACH END oc ON CENTER W.W.F. WELDED WIRE FABRIC
DESIGN CRITERIA
Governing Code 18 IBC Risk Category II
Wind Design Data
Earthquake Design Data
Gravity Load Data
loads are psf
Dead Live Snow
Rafters'-
•Solar-Ready3 20 0 25
Trusses (pitched)
*Pitches :5 8:12
*Solar-Ready3
Pitches:5 8:12
Top Chord 15 0 25
Bottom Chord 5 0 0
Floors: loads are psf
Dead Live Snow
Joistss 12 40 0
Garage Floor 90 40 0
Decks: loads are psf
Dead Live Snow
Joistss 50 60 25
Notes apply as called out in table above.
1 Rafters of sawn lumber or wood I -joists.
3 Dead load includes 5psf for photovoltaic panels.
5 Joists of sawn lumber or wood I -joists.
Soil Data
Company: Cobalt Geosciences Date: 9/17/20
*Includes F.S. = 1.5 per Geotech Report
Seismic Importance Factor, Ie 1.00
Site Classification D
Short Period Acceleration, SS 1.296
1-Second Acceleration, S1 0.458
Seismic Design Category D
Spectral Response Coefficient, SIDS 0.864
Spectral Response Coefficient, Spl 0.562
Allowable Soil Bearing 2000 psf
Passive Earth Pressure 275 *pcf
oo
Seismic Force Resisting System Table 12.2-1: A-15
2016 Equiv. Lateral Force Procedure
Response Modification Factor, R 6.5 Transverse
6.5 Longitudinal
Seismic Response Coefficient, CS 0.133 Transverse
0.133 Longitudinal
Seismic Base Shear, V 29267 Ibs
Active Soil Pressure 35 pcf
Coefficient of Friction 0.40
At -Rest Soil Pressure 55 pcf
Unit Weight of Soil 125 pcf
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
Allowable Soil Bearing 2000 psf
Passive Earth Pressure 275 *pcf
oo
Seismic Force Resisting System Table 12.2-1: A-15
2016 Equiv. Lateral Force Procedure
Response Modification Factor, R 6.5 Transverse
6.5 Longitudinal
Seismic Response Coefficient, CS 0.133 Transverse
0.133 Longitudinal
Seismic Base Shear, V 29267 Ibs
Active Soil Pressure 35 pcf
Coefficient of Friction 0.40
At -Rest Soil Pressure 55 pcf
Unit Weight of Soil 125 pcf
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
oo
Seismic Force Resisting System Table 12.2-1: A-15
2016 Equiv. Lateral Force Procedure
Response Modification Factor, R 6.5 Transverse
6.5 Longitudinal
Seismic Response Coefficient, CS 0.133 Transverse
0.133 Longitudinal
Seismic Base Shear, V 29267 Ibs
Active Soil Pressure 35 pcf
Coefficient of Friction 0.40
At -Rest Soil Pressure 55 pcf
Unit Weight of Soil 125 pcf
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
Active Soil Pressure 35 pcf
Coefficient of Friction 0.40
At -Rest Soil Pressure 55 pcf
Unit Weight of Soil 125 pcf
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
At -Rest Soil Pressure 55 pcf
Unit Weight of Soil 125 pcf
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
RESUB
BLD2023-0287 Aug 17 2023
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
�t
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
Internal Pressure Coefficient 0.18
Topographic Factor, Kt 2.23
Ground Elevation Factor, ICe 0.99
CITY OF EDMONDS
BUILDING DIVISION
BOUNDARY NAILS SHEATHING PER APPROVED PLAN
PER NOTES NOTES
300 MIN
2x FLAT BLK w/
DBL ROW OF
BOUNDARY NAILS
TRUSS
20 BRACE @ 48'bc w/
#A35 AT BTM
(8)16d EVENLY SPACED, 16d @ 16" oc GEB GABLE -END TRUSS BRACE
TYP U.N.0 TYP FACE NAILS BEAM N.T.S. GEBA
DISCONTINUOUS #CS16w/, __ SSS Number:
DBL TOP PLATE (13) 8d NAILS EA END _ _ � � s2209020
JL
POST SWR
Project Name:am iz
-
ROOF SHEATHING w/
EDGE NAIL PER I MIN 2x CONSTRUCT PER SW-A6
I ��� 94th AveIron VistaW Lot B
n
SW SCHED, BOUNDARY NAILS �/
TYP PER NOTES ' 4'-0" MIN I �_
FULL HEIGHT SPLICE Owner:
Q•
xz�
TRUSS BLKG TOP PLATE SPLICE DISCONTINUOUS DBL TOP PLATE
PER MFG DROPPED BEAM L H Inc
SHEATH SAME
AS SHEARWALL
..� BELOW BOUNDARY NAILS 7DTC2:: DIAPHRAGM TO COLLECTOR
OPTION MFG TRUSS TPS DOUBLE TOP PLATE SPLICE Project vocation:
TYp ROOF DIAPHRAGM N.T.S. DTCA 191xx 94th Ave W,
N.T.S. Edmonds, WA
GAP PER TRUSS TPSA
MFG SPECS 2x4 NAILER
1 BOUNDARY NAIL ALONG BOUNDARY NAIL ALONG Design Professional:
—L LENGTH OF COLLECTOR LENGTH OF COLLECTOR LQH, Inc
4y16 HTT5 EXPOSED 0,20 MFG TRUSS
RAFTER MAX NOTCH
#SDWS 0.152" x 6" COLLECTOR
2x4 FLAT FRMG TRUSS CLIPS , 2�" TO EACH RAFTER DIAPHRAGM PER
AROUND PERIMETER7 SHEARWALL TYP STRUCT NOTES
OF OPENING
INTERMEDIATE FRAMING ABUTTING PANEL EDGES
01
FTB FULL HEIGHT TRUSS BLOCK HTTS- A RTW RAFTER TO BEARING WALL DTC DIAPHRAGM TO COLLECTOR Loon00
N
N'._J.T.S. FTBA N.T.S. CTPF N.T.S. DTCA
'._J
MSTC w L
STRAP 4%6 HTT5KT ��
$� #HDU11 N
' J w
DBL 2x STUD I 2Y4" 32
z z
EDGE NAILING SW SHEATHING 6x6 BOUNDARY NAILS PER V
U.N.C. 18" ' RFA ROOF DIAPHRAGM �--� H U
STRAP MAY BE TRUSS TIGHT BOUNDARY NAILS PER C
AROUND RIMS
LOCATED 2x6 TOP RIM/BLOCK EDGE NAILS ROOF DIAPHRAGM Q)
HOLDOWN ON INSIDE u7
EMBEDDED MSTC STRAP -(A) HTT5KT- A HDU11- B 2x6 BTM RIM/BLOCK ���5`' z z
.� [FRH AT OPENINGS] Vic,10) = W
P off
STRAP SHOWN SHRINKAGE GAP �� am
AROUND CORNER 3°
(3)2x STUDS U.N.O. 716" � #HDU14 EDGE NAILS, TYP EDGE NAILS
STUDS PER SHEARWALL #H2,5 EA END SHEARWALL GEBcc
HOEDOWN SCHED 2�� 1/0 3z11 EA TRUSS �
SW SHEATHING C
SHEARWALL w/ TRUSS BEARING SHEARWALLS w/ TRUSS PARALLEL �
EDGE NAILING 6x6 u7
2x STUD STHD14 4x6 U.N.O. HDU8 U.N.C. 16"
SWR SHEARWALL ROOF CONNECTIONS x
0
o STHD14- A HDU8- A HDU14- B N.T.S. '._J SWM
HOLDOWN
2x STUD ANCHOR HDN HOEDOWNS
DIAPHRAGM PER NAILS PER
N.T.S. H DNA STRUCT NOTES SW SCHED WALL BASE
WALL BASE EDGE NAILS PLATE CONN
HOC HOLDOWN AT CORNER FLRRIM BLKG PLATE (SW ABOVE) (SW ABOVE)'
21
N.T.S. HOCA (OR ROOF GABLE) SOLID BLKG OR DIAPHRAGM PER
COLLECTOR STRUCT NOTES � 4z
RIM/BLKG
EDGE NAILS ���#� �� �
EXTENT OF EXTENT OF PROVIDE #A35 PER EDGE NAIL PROVIDE
SHEARWALL CRIPPLE STUD SHEARWALL DOUBLE TOP PLATE TPS SWF SWR BLKG @ 48"oc SW SCHED (SW BELOW) BLKG @48" oc
w/ JOPARALLEL DOUBLE -SIDED SHEARWALLS, w/ JOIST -WALL
INTERIOR SHEARWALLS, & PARALLEL This space reserved for
governing jurisdiction stamps
EXTERIOR SHEARWALLS EXT SHEARWALLS @ CANTILEVERS SHEARWALL TO FLOOR TO SHEARWALL
HEADER HEADER SW F SHEARWALL FLOOR CONNECTIONS
N.T. s. SWFA
#LSTA24 w/ MIN (9) -10d WINDOW
FASTENERS PER MEMBER TOP PLATE OPENING
U.N.O. :� I
DOOR WALL BASE WALL
ENI WALL PLATE CONN XX
PER SW SCHED DIAPHRAGM PER
ANCH PER STRUCT NOTES
KING STUD SW SCHED
TRIMMER STUD RIM/BLKG ANCH PER
COLLECTOR OR RIM 2x SILL U,N.O. SW SCHED
PER SW SCHED EDGE NAILS 2x SILL U.N.O. ORIGIN DATE; 8/15/2023
FDN FDN PER SW SCHED
REVISED; ----
4" x 4" IS THE MAXIMUM PENETRATION CRIPPLE STUD BASE PLATE SWB SWF _
OR HOLE THAT CAN BE ADDED TO A SHEARWALL SHEARWALLS TO FOUNDATION SHEARWALLS TO FLOOR TO FOUNDATION
0
[V
RESUB N
CTP1 COLLECTOR TO TOP PLATE SWE SHEARWALL ELEVATION SWB SHEARWALL BASE PLATE & FOUNDATION CONNECTIONS
Aug 17 2023 a
Ln
N.T.S. CTPF N.T.S. DRDDD N.T.S. SWBA
CITY OF EDMONDS
DEVELOPMENT SERVICES NI
DEPARTMENT , 00
�n
LQ
DIAPHRAGM
FLOOR JOIST BOUNDARY
PER PLAN NAILING
2x4 MIN BLOCK BOTTOM FLUSH
BETWEEN JOISTS w/ BEAM
0.148" 0 x 3" @ 8110c
HANGER
n
PERPENDICULAR FRAMING
FLOOR LEDGER
N.T.S.
SHEARWALL ABOVE
EDGE NAILS
LIGHTWEIGHT
CONCRETE SLAB
2 ADDITIONAL RIMS, U.N.O.
1 ADDITIONAL RIM, U.N.O. RIM BOARD IS NOT CONTINUOUS
RIM BOARD IS OVER THE OPENING
CONTINUOUS OVER
THE OPENING BEAR OVER BHS
STUDS PER
DOUBLE TOP EDGE NAILS
PLATE CONTINUES
OVER OPENING SHEARWALL BELOW
#SDWS 0.22" x 3"
SCREWS @ 16"oc
FLB
BOUNDARY
NAILS
#H2.5A MIN
@ ALL ROOF
MEMBERS
U.N.O. @
SHEARWALLS
d
0.25d
MAX
NOTCH
\_
NOTE; BEAM
SEE DETAIL SWR FOR SHEAR CONNECTIONS
RCBJ SHEARWALL ROOF CONNECTIONS AT BEAM
DIAPHRAGM
RAFTER
3%" MIN
N.T.S.
""1 & #CS16
6)10d
1OWN
Q STUDS
REQUIRED STUDS
BEAM
2x4 WALL
2x6 WALL
4x & 2-2x (SAWN)
3%x (GLB)
(2) 2x4
(2) 2x6
3%x (MANF)
6x & 3-2x (SAWN)
5%x (GLB)
(3) 2x4
(3) 2x6
5%x (MANF)
8x (SAWN)
6%x (GLB)
(4) 2x4
(4) 2x6
7x (MANF)
GIRDER TRUSS
(3) 2x4
(3) 2x6
REQUIRED TRIMMERS
HEADER
2x4 WALL
2x6 WALL
4x & 2-2x (SAWN)
3yx (GLB)
2x4
2x6
3%x (MANF)
6x & 3-2x (SAWN)
5%x (GLB)
----
(2) 2x6
5%x (MANF)
REQD
TRIMMERS
NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM
SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS
BEAM & HEADER SUPPORTS
N.T.S.
DOUBLE O
INTERSECTING JOISTS7
O�PLATE CONTINUES
SHALL BEAR IN HANGERS 0011 OVER OPENING
OVER OPENINGS RIM IS DISCONTINUOUS OVER OPENING
RIM CONTINUOUS OVER OPENING STW SHEAR TRANSFER TO SHEARWALL
N.T.S.
i FLUSH RIM HEADER, TYP T&G ROOF DEC
N.T.S. (2)10d @ INTERMEDIA
FRHA END BEARING SUPPORTS
VERTICAL GR
COMPRESSION BL(
MATCH STUDS AB
HOLDOWN
NUT ANDDOUBLE
ATUD INSTALLATION:
WASHER
WASHER
*ATUD TAKE UP
1) Remove shrink wrap from ATUD.
DEVICE
IMPORTANT: Do not remove activation pin until isolator
nut is installed and inspector is present.
2) Install ATUD with either end up over threaded rod
that extends up through Holdown anchor. IMPORTANT:
Activation pin must face out.
THREAD ROD
PER HOLDOWN
3) Install double washers and then nut on top.
SCHED
4) Finger -tighten nut plus an additional 1/3- to 1/2-turn
with a wrench.
PROVIDE COUPLERS
AS REQD TO EXTEND
5) Remove activation pin at time of inspection.
THREADED ROD TO
6) For questions and concern contact this office.
HOLDOWN
Activation
IL Rn
EMBED ANCHOR w
IN FND
EXTEND ROD TO FOUNDATION
PROVIDE (1) STUD
PER STRAP, TYP
SPECIFIED NAILS PER
EACH END LENGTH, TYP
END
LENGTH
DIAPHRAGM PER
STRUCT NOTES
END
RIM/BLKG
LENGTH
DIAPHRAGM PER
STRUCT NOTES
#CS16 STRAP(s)
END
LENGTH
7
END
LENGTH
#CS16 STRAP(s)
BEAM, 3%"
WRAP STRAP
WIDE MIN.
UNDER BEAM
STRAP BETWEEN FLOOR STRAP TO BEAM BELOW
SHEARWALL
COILED STRAP HOLDOWN
N.T.S.
#PSPN516 w/
BOTTOM PLATE 816d NAILS INTO
#PSPN58 TOP PLATE, E.S. #PSPN58 w/
FLOOR SHEATHIN 1-8d NAIL INTO
PLUMBING BASE PLATE, E.S.
PLUMBING
SHEARWALL O SHEARWALL
FLOOR
#PSPN516 1 Z" MIN 1 Z' MIN
NOTCH AS
REQUIRED
DBL TOP PLATE WALL STUD, TYP WALL STUD,
rl\TYP
ELEVATION VIEW TOP PLATE NOTCH BOTTOM PLATE NOTCH
PLAN VIEW
PENETRATION OF FRAMING - SHEARWALL
RAFTER PER
re
_F1
x x
x x
x x----
UNG
FE&
TYP
x
x x
x x
x x----
PLAN
9
DBD DECK BOARD DIAPHRAGM
N.T.S.
SHEATHING PER
SCHED
WALL FRMG
L
SHEATHING PER
SCHED
PLAN VIEW PLAN VIEW `SHEATHING PER
SCHED
DSW DBL SIDED SW AT ADJOINING WALLS
16" MA%
COLLECTOR SPLICE
N.T.S.
#LSTA24 w/
MIN (9) lld x 1 %"
FASTENERS PER MEMBER
DIAPHRAGM U.N.O.
COLLECTOR COLLECTOR
SPLICE OPTIONAL STRAP
LOCATION
COLLECTOR SPLICE
N.T.S.
DIAPHRAGM
CITY OF EDMONDS
BUILDING DIVISION
APPROVED PLAN
CSAA
#LSTA24 w/ MIN (9) -10d
FASTENERS PER MEMBER
U.N.O.
COLLECTOR V COLLECTOR
BEAM
DO NOT MAKE PENETRATIONS OR NOTCHES
IN THE SHADED AREA OF THE BEAM WITHOUT MIN CLEAR SPACING
PRIOR APPROVAL OF THE ENGINEER SHALL BE 8x THE
L/8 DIAMETER OF THE
LARGER HOLE
d/4
DEPTH Td2 0 t
d/4
DEPTH
CSAA
PENETRATIONS IN THIS AREA DO NOT
REQUIRE APPROVAL FROM THE ENGINEER
HOLES MUST BE ROUND AND ARE LIMITED TO
ly"OOR% DEPTH OF MEMBER, UNLESS
APPROVED BY THE ENGINEER
�L/8�
L/8 r L/2 T L/8
DO NOT MAKE PENETRATIONS OR NOTCHES
IN THE SHADED AREA OF THE BEAM WITHOUT
PRIOR APPROVAL OF THE ENGINEER
SPAN
y DEPTH
L
GLB
MIN CLEAR SPACING
SHALL BE 2x THE
DIAMETER OF THE
LARGER HOLE PENETRATIONS IN THIS AREA DO NOT
REQUIRE APPROVAL FROM THE ENGINEER
SPAN
— SPAN —
SAWN
DO NOT MAKE PENETRATIONS OR NOTCHES MIN CLEAR SPACING
IN THE SHADED AREA OF THE BEAM WITHOUT SHALL BE 2x THE
PRIOR APPROVAL OF THE ENGINEER DIAMETER OF THE PENETRATIONS IN THIS AREA DO NOT
LARGER HOLE REQUIRE APPROVAL FROM THE ENGINEER
%DEPTH
r -
DEPTH % DEPTH o
L------- O— — — — — — — -
DEPTH
PSL & LVL HOLES PERMITTED
IN MIDDLE %SPAN ONLY
DEPTH LSL ALLOWED HOLE ZONE DEPTH
SPAN
MAX HOLE DIAMETER SHALL NOT EXCEED 2" U.N.O.
MAX HOLE DIAMETER FOR LSL BEAMS SHALL BE:
PSL, LVL, & LSL 3" FOR 9%" DEPTH
3%" FOR 11%" DEPTH
4%" FOR 14"-16 DEPTH
SPAN
BEAM PENETRATIONS, TYPICAL DETAIL RES 2 B
Aug 17 023
N.T.S. N.T.S. N.T.S. DSWA L_J N.T.S.
CITY OF EDMONDS
DEVELOPMENT SERVICE
BP�
DEPARTMENT
SSS Number:
S2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
N N
O N O
i--1 t
Q w
� N
J w
z E
O
~ V
V_
H
� Ln
u7
p z
w
C/)
LCO
V
0)
C
N
u7
Ln
O
5 Ft
427A `
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 8/15/2023
REVISED: ----
S2.1
0
f'V
O
rn
0
[V
En
NI
a
NI
00
n
Ln
Ln
CITY OF EDMONDS
BUILDING DIVISION
HOLDOWN ANCHOR e
FOUNDATION WALL
MINIMUM STEM HEIGHT
REQUIRED TO ACCOMMODATE
ANCHORAGE PER
HOLDOWN SCHEDULE
FOOTING
L___
EMBEDDED
Y "r
I //
I
I
1
HOLDOWN
ANCHOR
EMBEDDED STRAP
SLAB r 12fI(2)#4CONT
TSF THICKENED SLAB FOOTING
Li N.T.S. TSFA
2" TYP
A.B. PER PLAN
2", TYP
A
a
d n .
a
>
d ' c
..4 .A A. A
I.
L HOLDOWN POST
A.B. PER PLAN
2
i I
7" MIN STEM WALL SHALL
BE 2'-0" DEEP MIN
(2) #4 HORIZ CONT
@ TOP OF WALL
1Z" CLC,
TYP R%"x3"x3"
1' 0" A36 BRIG PLATE
w/ DBL NUT
��
(4)#4xll
8 411
SECTION A -A
REINFORCED FOUNDATION ANCHOR
3/4" = V-0"
2x BLOCK UNDER
BEARING WALL
JOIST
VIDEEPEN
6'-0" MAX #A34 EACH SIDE
BEAM POST, TYP
A24 w/ (4)10d POST
OUNDATION AS REQD TO (2) POWDER INTO ONC (1'EMBED)FASTENERS
ATE FOR HOLDOWNFTG
NTS INTO WALL
BRIG SOIL
MHE I MINIMUM HOLDOWN EMBEDMENT
N.T.S.
THICKNESS
STEEP
EXCAVATU
WILL ALLC
STEPPED FOOTING
N.T.S.
MHE
RFA1
PBF2 I INTERIOR POST BEAM AND FOOTING - DROPPED CONDITION
N.T.S.
6-0" MAX
SOLID BLOCK,
MATCH WIDTH OF
POST BELOW
EACH SIDE
I'II JOIST
#A34 EACH SIDE
POST, TYP
A24 w/ (4)10d POST
(2) POWDER ACTUATED FASTENERS
INTO CONIC (1" EMBED)
FTG
BRIG SOIL
NOTE: 9" OF CS22 COILED STRAP AND (8)10d NAILS MAY BE USED IN LIEU OF THE ST9
PBFD INTERIOR POST BEAM AND FOOTING
N.T.S.
JOIST
6-0" MAX SOLID BLOCK,
MATCH WIDTH OF
POST BELOW
EACH SIDE
#A34 EACH SIDE
POST, TYP
A24 w/ (4)10d POST
(2) POWDER ACTUATED FASTENERS
INTO CONIC (1" EMBED)
FTG
BRIG SOIL
M9.9 rP
FOOTING SCHEDULE
CENTER UNDER CONCENTRATED LOAD U.N.O.
FOOTIIM SIM
REINFORCEMENT
ID
WIDTH
(Transverse)
LENGTH
(Longitude)
THICKNESS
LONGITUDE
TRANSVERSE
F1.5
V-6"
V-6"
8"
(2) #4's
(2) #4's
F2.5
2'-6"
2'-6"
1 10"
1 (3) #4's
(3) #4's
F3
3'-0"
3'-0"
10"
(4) #4's
(4) #4's
LONGITUDE REINF
TRANSVERSE REINF POST TO FTG
THICKNESS
LENGTH
WIDTH (LONGITUDE)
(TRANSVERSE)
PLYNTH ON FTG
FOOTING, TYPICAL
N.T.S.
r GR BEAM
�....��.�.... 'I REINF
MATCH HORIZ �o
STD 900 HOOK INTO REINF
INTERSECTING GR BEAM V-6" CORNER BAR @ ALL
OUTER REINF
REINF
•
FTG @ WALL
FTG @ WALL CORNER
APPROVED PLAN
FTG UNDER SLAB ON GRADE
STD 900 HOOK INT MATCH HORIZ
INTERSECTING GR BEAM REINF
ALTERNATE EA BAR V-15" CORNER BAR @ ALL
OUTER REINF
REINFORCEMENT AT INTERSECTIONS
N.T.S. RIAA
(2)-ROWS STAGGERED
8d MIN @ 6"oc
FLR DIAPHRAGM FDN WALL
MIN (3) - 8d TOENAILS
JOIST TO SILL
FLR DIAPHRAGM
JOISTS
FTGC
MIN (3) - 8d TOENAILS
BLK TO SILL
FLR SHEATHING w/
10d @ 4"oc TO FRMG & BLKG
JOISTS
2x TIGHT -FIT BLOCKS @ 48"oc
FOR (2) FULL JOIST SPACES
JD JOIST DROPPED JB JOIST BEARING JP JOIST PARALLEL
NOTE: METAL FASTENERS LESS THAN %" O SHALL BE HOT -DIPPED GALVANIZED WHEN IN CONTACT WITH P.T. LUMBER
FTCJ FOUNDATION WALL TOP CONNECTIONS RESUB
N.T.S. CITY E FTCA
DEVELOPMENT
SERVICE
DEPARTMENT
SSS Number:
52209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
N (V
O N O
rl
1-1 0
O "' Ln
[V
J w
Z E
O
~ V
V_ H
CC
� Ul)
to Z
w
C/)
O
V
p1
C
N
cc Ln
U .
ro 427A
tOh!AL
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 8/15/2023
REVISED: ---S212
-
CITY OF EDMONDS
BUILDING DIVISION
d
D
180°
4d or
2%" MIN.
BAR
D
#3
1 %"
#4
2"
#5
2 %"
#6
4y"
#7
5%"
#8
6"
LEGEND
d = BAR DIAMETER
D = FINISHED BEND DIAMETER
Note:
1, STANDARD HOOKS SHALL CONFORM TO ACI 318
SECTION 25.3
12d 2, REINFORCING SHALL BE COLD BENT,
STANDARD HOOKS
N.T.S.
(2) #4 CONT 8" U.N.O.
@ TOP OF WALL P.T. SILL PLATE
& A.B.
CONC SLAB ON GRADE CONC STEM WALL
CTRD ON FTG, U.N.O, 3'-0"
MAX
BETWEEN
GRADES
4'-6" MAX FINISH GRADE
24" MIN #4 VERT
@ 16"oc
/ #4 @ 16"oc
#4 HORIZ DOWELS w/
@ 12" oc 14" EXTENSION 18" MIN
INTO WALL & STD
HOOK IN FTG
16"x8"
CONC FTG U.N.O.
3" CLR
#4 LONG @ 12" oc MAX, BRG SOIL I 1=1
U.N.C. (2 BARS MIN) TjI
NOTES:
-CENTER VERTS AND DOWELS IN STEM WALL
-DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN
EMBEDMENTS
-DEEPEN EXCAVATION TO PROVIDE MINIMUM FOOTING DEPTH
FWX FOUNDATION WALL - STEM
N.T.S.
BAR DEVELOPMENT LENGTHS
SIZELAP
SIZE
STRAIGHT
HOOK
#4
18"
18"
6.5"
#5
24"
24"
#6
30"
24"
10.25"
THIS IS A GRAPHICAL REPRESENTATION
ONLY, THERE IS NO BEND IN THE
VERTICAL BAR
DOWEL
w/ STD HOOK
TOE BARS MUST HAVE FULL
DEVELOPMENT LENGTH ON
BOTH SIDES OF THIS LINE. AN
EXTENDED DOWEL BAR MAY
REPLACE A SEPARATE TOE BAR
e
O
S
A B C
HORIZ
VERT
2" COVER
@ VERT &
DOWEL
CONCRETE WALL
DOWEL w/
900 HOOK
EXTENDED TO TOE
CONCRETE
FOOTING
H
D
3" COVER
LONG I I=I BRG SOIL =III=
DRAINAGE PER CODE
SRW I SITE RETAINING WALL
SCHEDULE
ACI 318-14 FWCRA ( 45 2000 300 0.4 8H) (BSFO SO SLO-0 AFO)
DIMENSIONS
H
E
S
D
A
B
C
W
(FT -IN)
(FT -IN)
(IN)
(IN)
(IN)
(IN)
(IN)
(IN)
4-0
3-6
6
12
24
8
12
1 44
REINFORCEMENT *1
H
DOWEL
LAP
VERT
HORIZ
LONG
(FT -IN)
(IN oc)
(IN)
(IN oc)
(IN oc)
(IN oc)
4-0
#4 @ 12
20
#4 Ob 12
#4 Ob 12
#4 @ 8
*NOTES:
1 Clear cover requirements u.n.o. - 3" to soil, 2" to forms in all other locations
2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL is
used.
H
p 3" CLR
KEY w/
I STD 90 HOOK
AT TOP
W
A B C
BACKFILL' �\\!
WALL ��i�
HORIZ
CONCRETE SLAB
2" CLR
� �•---�� HORIZ
LAP
CONT
j BRG SOII
VERT
2" CLR @
VERT &
DOWEL
DOWEL w/
STD 900 HOOK AND
EXTEND TO TOE
FWC21 CANTILEVERED FOUNDATION WALL
SCHEDULE
ACI 318-14 FWCCB ( 35 2000 275 0.4
� APPROVED PLAN �
1 SO/50 SLO.69-0.46
DIMENSIONS
H
D
K
A
B
C
W
(FT -IN)
(IN)
(IN)
(IN)
(IN)
(IN)
(IN)
10-0
12
34
r 36
1 10
1 8
54
REINFORCEMENT *1
H
DOWEL
LAP
VERT
HORIZ
CONT
KEY
*2, *3
*2
(FT -IN)
(IN cc)
(IN)
(IN cc)
(IN oc)
(IN cc)
(IN cc)
10-0
#5@5
40
#5@10
#4@10
#4@8
#4@8
*NOTES:
1 Clear cover requirements u.n.o. - 3" to soil, 2" to forms in all other locations
2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL
is used.
3 Extend the DOWEL to within 2" of the TOE edge
SHA U N.T.S. SRWA L_J N.T.S. FWCB
FWX
DOWELS MAY BE
°
2" COVER
COMBINED WITH THE
@ VERT &
VERTICAL AND/OR TOE
DOWEL
BARS PROVIDED THE
O
DOWEL SIZE AND
SPACING IS USED
O
HEEL BARS MUST HAVE FULL
O DEVELOPMENT LENGTH ON
BOTH SIDES OF THIS LINE
e
° CLR_ CLR
3" T—
CLR TOE HEEL
NOTE: THIS DETAIL IS INTENDED TO PROVIDE SUPPLEMENTAL INFORMATION TO
THE FOUNDATION DETAILS PROVIDED. THE INFORMATION PROVIDED ON THOSE
DETAILS WOULD SUPERCEDE THIS DETAIL.
I BAR DEVELOPMENT - SUPPLIMENTAL INFO
FTC FTC
r 1 P.T. SILL PLATE #4 CONT @ 24"oc w/ r 1
#4 CONT w/in I & A.B. (1) #4 w/in
TOP 12" OF WALL TOP 12" OF WALL
� I
J CONC STEM WALL u.— J
8 U.N.O. 8" MIN CTRD ON FTG, U.N.O.
VERT & DOWELS
CTRD IN STEM FINISH GRADE FINISH 8'-0" MAX FINISH GRADE `.
4'-0" MAX VERT ` (.�'//may �'��'�•' FOR 8" MIN 3 -D �
16" MIN #4 @ 48"oc, #4 @ 48"oc
THICK WALL MAX
CORNERS & DOWELS w/ OR-
11 14" EXTENSION 18" 8'-0° 4'-0" 4'-6" MAX
BACKFILL INTO WALL & STD MIN MAX MAX FOR 6"
HOOK IN FTG THICK WALL BACKFILL
/
#4 AT BTM 2" CLR
CONC FTG
PER PLAN w/ 3" CLR_ I BACKFILL
(2) #4 CONT, z BRG SOIL (I I I I II
U.N.O.(—
NOTES:
0 L _SJ
-DETAIL PER CODE FOR SW,SP,GW,GP,GM,GC,SM,SM-SC AND ML SOILS
-TEMPORARILY BRACE WALL IF BACKFILLING BEFORE BRG SOIL -III= I I BRG SOIL -1
THE TOP CONN IS CONSTRUCTED = I II, 1 II 11-
-DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN ALL OTHER INFORMATION PER STANDARD ALL OTHER INFORMATION PER STANDARD
EMBEDMENTS
STANDARD DEEP
FLOOR LATERALLY SUPPORTS TOP OF STEM NO LATERAL TOP SUPPORT
FWS FOUNDATION WALL - STEM
HORIZ
VERT
2" CLR @
VERT &
DOWEL
DOWEL w/
STD 900 HOOK
2„ 2
CLR CLR
HEEL
3"
CLR
FWC31 CANTILEVERED FOUNDATION WALL
SCHEDULE
ACI 318-14 FWCDB ( 35 2000 275 0.4 7H) (BSFO SO SLO.6-0.45 A
DIMENSIONS
H
E
S
D
A
B
C
W
(FT -IN)
(FT -IN)
(IN)
(IN)
(IN)
(IN)
(IN)
(IN)
5-0
4-6
6
10
8
8
16
32
6-0
5-6
6
10
8
8
20
36
8-0
7-6
6
10
8
8
28
44
REINFORCEMENT
*i
H
D
3
LA PE
VERT
HORIZ
CONT
HEEL
2W
(FT -IN)
(IN oc)
(IN)
(IN oc)
(IN oc)
(IN oc)
(IN oc)
5-0
#4 @ 12
22
#4 @ 12
#4 @ 12
#4 @ 8
none
6-0
#4 @ 12
22
#4 @ 12
#4 @ 12
#4 @ 8
none
8-0
#4@5
22
#4@10
#4@12
#4@8
#4@8
*NOTES:
1 Clear cover requirements u.n.o. - 3" to soil, 2" to forms in all other locations
2 DOWEL and VERT may be the same piece provided the size and spacing of the
DOWEL is used.
3 Extend the DOWEL to within 2" of the TOE edge
N.T.S. FWSA U N.T.S. FWCD
A B C
FRMG
T
HORIZ
`NIJIALKHLL
<' \K\
VERT
2" COVER
@ VERT &
DOWEL
H
CONCRETE WALL
DOWEL w/
900 HOOK
EXTENDED TO TOE
a
J
CONCRETE SLAB
/ /\ xml/\
CONCRETE FOOTING\/vie
/ D
3" COVER
—
\
CONT
1I BRG SOIL
DRAINAGE PER CODE
FWC1 I FOUNDATION WALL - CANTILEVER
SCHEDULE
ACI 318-14 FWCB ( 45 2000 0) ( S )
DIMENSIONS
ID
H
A
B
C
I D
(FT -IN)
(TN)
(TN)
(TN)
(TN)
4
4-0
12
8
8
10
5
5-0
20
8
8
10
6
6-0
28
8
8
10
7
7-0
24
8
16
10
8
8-0
34
8
16
10
9
9-0
44
8
16
12
10
10-0
44
10
16
12
11
11-0
56
10
18
12
12
1 12-0
62
10
22
14
REINFORCEMENT *1
ID
DOWEL
*2
LAP
(IN)
VERT *2
HOR7Z
CONT
4
#4 @ 10
32
#4 @ 10
#4 @ 12
#4 @ 10
5
#4 @ 10
32
#4 @ 10
#4 @ 12
#4 @ 10
6
#4 Co) 6
32
#4 @ 12
#4 @ 12
#4 @ 10
7
#5@8
40
#50 16
#4 @) 12
#4 @) 10
8
#5@6
40
#5@ 12
#4@ 12
#40 10
9
#5@5
40
#5@ 10
#4 (-a 12
#4@9
10
#5@5
40
#5@ 10
#4 @) 10
#4@9
11
#5Co
40
#5@8
#4@ 10
#4@9
12
#5 @ 4
40
#5 @ 4
#4 @10
#4 @ 6
*NOTES:
1 Clear cover requirements (3" to soil, 2" to forms in all other locations)
2 DOWEL and VERT may be the same piece provided the size and spacing
of the DOWEL is used
N.T.S. �_J
N.T.S. FWCB
HORIZ
VERT
2" CLR @
VERT &
DOWEL
DOWEL w/
STD 900 HOOK
2„ 211
CLR HEEL CLR
3"
CLR
FWC41 CANTILEVERED FOUNDATION WALL
N.T.S.
SCHEDULE
ACI 318-14 NCDB ( 35 2000 275 0.4 7H) (BSFO S50 SLO.6-0.45 AFO)
DIMENSIONS
H
E
S
D
A
B
C
W
(FT IN)
(FT -IN)
(IN)
(IN)
(IN)
(IN)
(IN)
(IN)
11-0
9-C
24
14
14
10
44
68
REINFORCEMENT
*1
H
DOWEL
LAP
VERT
HORIZ
CONT
HEEL
(FT -IN)
(IN oc)
(IN)
(IN oc)
(IN oc)
(IN oc)
(IN oc)
11-0
#505
40 #5@10 #4010
#5@8
#4@8
*NOTES:
1 Clear cover requirements
u.n.o. - 3" to soil, 2" to forms in all
other locations
2 DOWEL
and VERT
may be the same piece provided
the size
and spacing of the
DOWEL is used.
RESUB
Aug 17 2023
CITY OF
DEVELOPMENT SERVIEDMONDSCFWCD
DEPARTMENT
SSS Number:
S2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
N (V
O N O
i--1 l
J ^
p w Ln
� N
J w
z
O
~ U
V H
CC
� Ln
u7
p z Ul)
w
c.n 3:
O
U
C3)
C:
N
u7
Ln
O
4
42771
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 8/15/2023
REVISED: ----
S213
CITY OF EDMONDS
BUILDING DIVISION
TOP STEM: 246.04'
BACKFILL, TYP \ \ \ \\ MAY
-- -
NATIVE BEARING
S0I4-TYP
TOP STEM: 235. 11 4=— 1 R-IIJ RIGID INSULAT=,
FRI
— PRESSIVE.STRENGGTT i,
6" MIN DEPTH, TYP
CONSULT / \ • \
L ENGINEER TO VERIFY
EXCAVATION CUTS
SECTION A -A
N.T.S.
/ TOP STEM: 246.04'
FWC3
BACKFILL,
2'-011 TOP STEM: 236.96'
NATIVE BEARING
S6I�TYP - .•
TOP STEM: 235 0'
FOOTING BEYOND R-10 RIGID INSULATION,
_ \du rof 101 PREStVf-S
CONSULT AFD \ / 6" MIN DEPTH TYP
GEOTECHNICAL —
ENGIAI€ER CONSULT AFD
ICAL
ENGINEER
CONSULT �
ICAL
ENGINEER TO VERIFY
EXCAVATION CUTS
D-D SECTION D-D
N.T.S.
—
T
F(
0
9
DETERMINING THE DEPTH OF
ADJACENT FOOTINGS DISTANCE "B" SHALL NOT BE GREATER THAN DISTANCE "A"
- DEEPEN EXCAVATION AS REQ'D
FOUNDATION
OR FOOTING
AFD ADJACENT FOUNDATION DE SU B
172023
N.T.S. CITY OF E
DEVELO"EN7 As
DEPAR M N
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
c.n f V
O N O
H 0
J
0 w Lr)
(V
J w
Z
o
V H
GC
Ln
o Z
Z �
W
0
U
61
6
N
Ln
Ln
�V)
X
O
42T71 p
tONAL �1Q
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 8/15/2023
REVISED: ---I S I I
-
0
[V
O
0l
O
('V
CA
ro
N
NI
ro
Ln
Ln
Ln
0I
n
Lr)
Ln
CITY OF EDMONDS
BUILDING DIVISION
BACKFILL, TYP —/�
CONSULT
GEOTECHNICAL
ENGINEER TO VERIFY
- EXCAVMN CUTS
SECTION B-B
N.T.S.
NATIVE FARING—
_ SOIL, TYP —
N.
FOOTING BEYOND
=CF�Tr:CW�ITCAI
SECTION C-C
N.T.S.
F(
0
9
DETERMINING THE DEPTH OF
ADJACENT FOOTINGS DISTANCE "B" SHALL NOT BE GREATER THAN DISTANCE "A"
- DEEPEN EXCAVATION AS REQ'D
FOUNDATION
OR FOOTING
AFD ADJACENT FOUNDATION DE SU B
172023
N.T.S. CITY OF E
DEVELOPMENT S
DEPAR M N
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
c.n f V
O N O
H 0
J
0 w Lr)
(V
J w
Z
0
V H
GC
Ln
o Z
Z �
W
0
U
61
6
N
Ln
Ln
�V)
X
O
C
�7
42771 p "Z
4NA L ^1Q
This space reserved for
governing jurisdiction stamps
ORIGIN DATE: 8/15/2023
REVISED: ---S215
-
CITY OF EDMONDS
BUILDING DIVISION
SYMBOL
LEGEND - FOUNDATION SLEXP
*HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
— — —
CONCRETE WALL AND CONTINUOUS FOOTING
See CONCRETE and REINFORCING BAR specifications per DETAIL FWS.
— — —
CONCRETE WALL AND CONTINUOUS FOOTING
See CONCRETE and REINFORCING BAR specifications per DETAIL FWX
F_ -1 F2
SPREAD FOOTING
See CONCRETE and REINFORCING BAR specifications per DETAIL FTG.
L I
SF
THD
I
J � L
L
FOUNDATION PLAN
1/4" = V-0"
T" I Q @
FWC3 (TOP OF WALL
F_
DEPRE
4 SLAB ON GRADE w/
6x6W1.4xW1.4
W.W.F.
IF
I
I
STEM WALL 9",
OUR SLAB OVER
II
I
TSF 14" WIDE,
TYP U,N,O.
24" WIDE TSF
FWC2 i /" O x 12" HEX -HEAD
ANCHOR w/ 10" ERF
EMBEDMENT FOR
#HTT5KT ABOVE
— F2 F1.5 PROVIDE CLEARANCE OF
F_ -1 18" MIN FOR JOIST AND
I I L -1 12" MIN FOR BEAMS TO
L J FINISHED GRADE BELOW
F— P-O" 5'-9"
F1,5 F1S
I F —1 F —1 4" SLAB ON GRADE w/
6x6 W1.4 x W1.4
W.W.F.
6'-9" 6'-0" 6'-3"
FWS
I =8"x16"
F
4" SLAB ON GRADE w/
6x6 W1.4 x W.W.F. F_ J L
I
8" STEM FWS
w/ 8"x16" FTG
TYP U.N.O. LJ
I I I
II IL
F_
I
0 0
FWC4
A -A FWC4 MAX RETAINED HEIGHT = 11'-0" MAX RETAINED HEIGHT = 10'-0
D-D MAX WALL HEIGHT - = 0""
MAX WALL HEIGHT = 12'-0" SF
J� L`
71 FF
RFA
RFA
U_
af
I
F3
F_ 71 I #
I I I I
K/" O x 12" HEX -HEAD
ERF ANCHOR w/ 10"
EMBEDMENT FOR
#HTT5KT ABOVE
4 SLAB ON GRADE w/
6x6 W1.4 x WIA
W.W.F.
B-B MAX RETAINED HEIGHT = 11'-0"
MAX WALL HEIGHT = 12'-0"
J
APPROVED PLAN
(2) #4 CONT
@ TOP OF WALL
D14
PROVIDE CLEARANCE OF
18" MIN FOR JOIST AND
12" MIN FOR BEAMS TO
FINISHED GRADE BELOW
MAX RETAINED HEIGHT = 10'-0"
MAX WALL HEIGHT = 10'-0"
C-C
J
a
RESUB
Aug 17 2023
DO NOT SCALE - REFER TO ARCHITECTURAL SHEET�E ?IM � i Es
DEPARTMENT
4
SF
SF
SSS Number:
s2209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
N (V
O N O
i--1 0
J ^
pp w Ln
J w
z E
O
~ V
V H
CC
c~ Ul)
u7
p z
p
w
LC 0
V
6
C
N
u7
V)
O
40 `
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
1
0
f'V
O
O
[V
c'V
NI
a
Lr)i
00
n
Un
CITY OF EDMONDS
BUILDING DIVISION
SYMBOL LEGEND
DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM.
DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like.
SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections
per the SHEARWALL SCHEDULE.
#HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max
spacing between members will be indicated in bold type with a symbol which is representative of the layout of the
entire level.
APPROVED PLAN
SLEXP
M
POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on
the plans.
INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL
FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan.
_JAL u
HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL
STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan.
BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 4x8 DF #2 at dropped
condition u.n.o. Flush headers (FRH) shall be 2-1 % x 14 LSL RIM at joists u.n.o. Reference detail FRH for
installation of the flush rim header.
WALL WALL WALL WALL
LINE LINE LINE LINE
A B C D
Fi>
F>
I>
FIRST FLOOR SHEARWALLS & FRAMING ABOVE
1/4" = V-0"
RESUB
DO NOT SCALE - REFER TO ARCHITECTURAL SHEETOL RM ES
DEPARTMENT
SSS Number:
52209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
1
0
CITY OF EDMONDS
BUILDING DIVISION
#CS16
3-2x6 STUDS
APPROVED PLAN
SYMBOL LEGEND SLEXP
-------------------
DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM.
POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on
DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like. the plans.
— — — — — — — — — — k \ \ \
SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL
per the SHEARWALL SCHEDULE. FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan.
#HOLDOWN MODEL I J I L I
JIJ
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are I HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan.
' BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are
JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 4x8 DF #2 at dropped
spacing between members will be indicated in bold type with a symbol which is representative of the layout of the condition u.n.o. Flush headers (FRH) shall be 2-1 % x 14 LSL RIM at joists u.n.o. Reference detail FRH for
entire level. installation of the flush rim header.
WALL
LINE
A
WALL
LINE
B
J
CD
zz
�o
3A TRIMMER w/
#A34 @ TOP
#A34 @ BTM,
N N
TYP @ WINDOW
CS
SW
3 2x6 STUDS
D2
2-1 a x 7 % LVL RIM
3: 00
m
3: �0
m
0
LIGHTWEIGHT CONCRETE (115 pd) SLAB @,
OVER DIAPHRAGM, 3%" MAX THICKNESS
DEAD LOAD 50 PSF MAX
LIVE LOAD 60 PSF MAX X
SNOW LOAD 25 PSF MAX
3% x 14 LSL (2-1)
MASTER BWTH
o
U
3-2x6 STUDS I o
J U J
C4
� o �
x x
�I I X
WALL
LINE
C
BEAM TO ( b
TOP PLATE
DROPPED 7 x 14 PSL (2-10)
4-26 STUDS
COVERED PORCH
HDR (2-13) HDR
CD
MASTER BEDROOM
o
3
5%x14PSL (22) L
�4x10STUD a
0
—J ---------------
— — —
_1F
c
5-2x6 STUDS CS2 SIM
a
o°
0'
CS I
(9)
(2) #CS16
I
I
� I
0
oc I
o
Na
I
CD
DROPPED 3 % x 11 % LSL (2-3) o
M
AS DRY
\ X
2-2A TRIMMERS \
�
CD
V
f
3 Z x 14 LSL (2-5)Z,
WALK-1 N BEARING WALL
TYPE ABOVE
CONTINUOUS DROPPED
7x14 PSL (2-4)
SECOND FLOOR SHEARWALLS & FRAMING ABOVE
1/4" = V-0"
CTP2
#HTT5KT o
HANG TO
LEDGER w/
0.148" x 1 %" NAILS 2x12 LEDGER w/
#SDWS 0.27 x 3 y"
CRAWL SPACE @16"oc
N
� � O
CdJ
x
N
#JB TO
SILL PLATE
o + Nw
jI
I
L�
SW
ERF c4
0
0
X
7
MESH RM
HDR (2-8)
SW
D2
BATH #2
ERF
m
_
HDR (2-7)
6,8 HDR (2-6)
2x6 @ 16"oc
T�1.4 1
FRH (2-1
BEDROOM #2
SW
C4
2x6 @ 16"oc
BEDROOM #3
J
M
SW
D2
WALL
LINE
D
#
#STHD14
CONCRETE (145 pd) SLAB OVER
c
DIAPHRAGM, 6Y' MAX THICKNESS #'
DEAD LOAD 90 PSF MAX
o LIVE LOAD 40 PSF MAX
X
CRAWL SPACE
RAT SLAB
#BA TO
SILL PLATE
RESUB
Aug 17 2023
DO NOT SCALE - REFER TO ARCHITECTURAL SHEET�ETL%RM ES
DEPARTMENT
SSS Number:
52209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
N N
O N O
i--1 o
J ^
Q w In
� N
J Lu
Z E
O
~ V
V_ H
DC �
Ln
u,
0 Z
w
V)
LCO
V
p1
c
aD
u7
�Ln
V
O
Is
,S t0 N L 3
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
1
1
f'V
O
O
[V
c'V
NI
a
Ln
Lr)i
00
n
Ln
CITY OF EDMONDS
BUILDING DIVISION
*CS16 BE
TO STU
I>
SYMBOL LEGEND
DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM.
DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like.
SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections
per the SHEARWALL SCHEDULE.
#HOLDOWN MODEL
HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are
wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE.
JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max
spacing between members will be indicated in bold type with a symbol which is representative of the layout of the
entire level.
APPROVED PLAN
SLEXP
M
POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on
the plans.
INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL
FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan.
_JAL u
HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL
STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan.
BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are
indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 4x8 DF #2 at dropped
condition u.n.o. Flush headers (FRH) shall be 2-1 % x 14 LSL RIM at joists u.n.o. Reference detail FRH for
installation of the flush rim header.
WALL WALL WALL WALL
LINE LINE LINE LINE
A B C D
THIRD FLOOR SHEARWALLS & FRAMING ABOVE
1/4" = V-0"
RESUB
DO NOT SCALE - REFER TO ARCHITECTURAL SHEETkRL RM ES
DEPARTMENT
SSS Number:
52209020
Project Name:
Iron Vista - 191xx
94th Ave W Lot B
Owner:
LQH, Inc
Project Location:
191xx 94th Ave W,
Edmonds, WA
Design Professional:
LQH, Inc
M
N (V
O N O
i--1 0
J ^
O w Ln
[V
J W
Z E
O
~ V
V_ H
DC
Ln
C Z
Loon
O
V
D)
C
N
�Ln
O
�7
42771p
This space reserved for
governing jurisdiction stamps
ORIGIN DATE; 8/15/2023
REVISED; ----
1
2
f'V
O
O
[V
c'V
NI
Lr)i
00
n
Un