Loading...
APPROVED BLD2023-1286+Structural_Plan+10.13.2023_5.05.58_PM+3840819SHEARWALL SCHEDULE SW EXP Notes apply as called out in table below. 1 Anchor bolts embedded at least 7", or 1/2"0 #Titen-HD w/ 4" min embed. See detail SWB. 2 #MASAP can be installed instead of sill bolts with washers. When replacing 1/2"0 sill bolts use 7-10dx11/2" nails (minimum nailing) and when replacing 5/8"0 sill bolts use 9-10dx11/2" nails (maximum nailing). 3 See detail SWF. Connections vary depending on condition. 3a May substitute 16d toe nails @ 8"oc for *A35. 4 See detail SWR. For gable -end roof connections see detail SWF. 5 See detail SWB. 6 Abutting panel edges require a 2-2x (lamination connection same as WALL BASE PLATE), 3x, or greater stud. 8 The plate washer shall extend to within 1/2" of the edge of the bottom plate that receives the sheathing or rim. At double -sided shearwalls, stagger on both plate edges. SHEAR FLOW CONNECTIONS / SPACING S SILL -TO - FLOOR -TO - ROOF -TO - WALL BASE PLATE CALL FOUNDATION 1, 2 SILL &WALL WALL 4 5 OUT 5/8"0 @ 60"oc or #A35 @ *H1 @ 16d @ 10"oc /�i A 1/2"0 @ 60"oc 32"oc 3a 24"oc 5/8"0 @ 50"oc or #A35 @ #LS50 @ 16d @ 6"oc p v 1/2"0 @ 40"oc 24"oc 32"oc 5/8"0 @ 48"oc or #A35 @ #LS50 @ 16d @ 4"oc C 1/2"0 @ 32"oc 16"oc 24"oc 5/8"0 @ 24"oc or #A35 @ #LS50 @ 16d @ 3"oc D 1/2"0 @ 16"oc 8 12"oc 12"oc 5/8"0 @ 16"oc or #A35 @ #LS50 @ 16d @ 2 oc E 1/2"0 @ 12"oc 8 1 8 oc 8 oc HOLDOWN SCHEDULE N WALL SHEATHING CALL OUT SHEATHING THICKNESS EDGE NAILS 6 7/16" 8d @ 6"cc 4 7/16" 8d @ 4"oc 3 7/16" 6 8d @ 3"oc 2 7/16" 6 8d @ 2"oc 1 Deepen the foundation as needed to provide the required holdown embedment into the foundation wall. See Detail MHE 2 Fasten to the end framing members of the shearwall, u.n.o. 3 FOUNDATION ANCHOR may be extended with threaded rod and coupler as required. 4 Provide the minimum embedment and edge distances specified by the manufacturer. 5 Attach to (2) 2x studs minimum (lamination connection same as WALL BASE PLATE; stagger nails), u.n.o. 6 See detail HDN for installation. HOLDOWN / STRAP 1, 2, 4, 6 FASTENERS 5 FOUNDATION ANCHOR 1, 3, 4, 6 COMMENTS *STHD14/14RJ 30-10d common N/A *HTT5KT 26 - *SD #10x21/2- #SB5/s"x24 2-2x4 Min Post U.N.O. *HDU8-SDS2.5 20 - #SDS1/4x21/2 *SB'/sx24 4x6 Min Post U.N.O. *HDU11-SDS2.5 30 - #SDS1/4x21/2 1"�T.R. 6x6 Min Post, See detail RFA *CS16 22-10d common N/A 13" Min End Length, See detail CSH *MSTC66 68-10d common N/A equal number of nails to both connected elements The following documentation shall be available on ' site for the building inspector: • FxJ COE APPROVED ARCHITECTURAL PLAN SET '. COE APPROVED STRUCTURAL PLAN SET 1 COE REVIEWED CALCULATION PACKET ■ ■ ❑ ENERGY CREDIT WORKSHEET ' 1 ❑ SITE PLAN ■ n CIVIL PLAN i ■ ■ ❑ 1 1 ❑ ■ 1 ■ GENERAL STRUCTURAL NOTES CODE All conditions, materials and construction shall conform to the code specified in the DESIGN CRITERIA, or other codes required by the governing jurisdiction. PROTECTION Through maintenance and current best practices, provide a building envelope that will preserve the integrity of the structure throughout it's lifetime. INSPECTIONS Notify Building Department for inspections required by local jurisdiction. SOILS Bearing capacity of soil shall be per DESIGN CRITERIA or greater. Footing shall bear on solid undisturbed level soil devoid of any organic material and below indicated frost line. COMPACTED FILL shall consist of predominately Well -Graded, granular soil, free of organic material and debris. Fill should be placed in maximum 8" loose lifts and compacted to a minimum of 95 percent of the maximum density at optimum moisture content determined by ASTM D-1557 test procedures. BACKFILL shall be free draining and without organic material and debris from one of the following soil classes SM-SC, SM, SP, SW, GC, GM, GP, and GW. FOUNDATIONS AND RETAINING WALLS Extend footings to undisturbed bearing soil. Do not backfill until all slabs and/or horizontal diaphragms are constructed, otherwise provide temporary bracing to resist movement. There shall be no machine compaction on the retaining side of the structure for a distance equivalent to 2/3rds the wall height. SILL PLATES Use pressure treated 2x plates u.n.o. Embed anchor bolts at least 7" (expansion anchors 4"). Use 3"x3"x0.229" washers. There shall be a minimum of two bolts per piece spaced not more than 6 feet apart, with one bolt located not more than 12" or less than 4" from each end of each piece. CONCRETE fc = 3000 psi minimum for environmental exposure (2500 psi used in structural design, or unless greater psi indicated on the plans). 5 1/2 sacks of cement per cubic yard of concrete and a maximum of 6 gallons of water per 94 lb sack of cement. Maximum slump is 4". Segregation of materials shall be prevented through proper handling and placement. REINFORCING STEEL #4 bars and larger shall be Grade 60 deformed bars, and #3 bars shall be Grade 40 (u.n.o.), in accordance with ASTM A-615. Lap splices 32 bar diameters u.n.o. Welded wire fabric shall conform to ASTM A-185 and shall be 6x6 - W1.4xW1.4. Lap one full mesh at splices. See applicable detail(s): BD SH CLEAR COVER 3" clr when cast against Earth and 2" clr in all other locations, u.n.o. See applicable detail(s): RI FOOTING DRAINAGE Footing drainage per Building Code section 1805.4.2 & Residential Code section R405.1. WOOD FRAMING in contact with concrete or masonry, or exposed to weather, shall be pressure treated. Numbers in parenthesis, IE (1-1), refer to corresponding engineering calculations. CONNECTORS AND FASTENERS Fasteners, including nuts and washers, and connectors in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. EXCEPTION: Plain carbon steel fasteners, including nuts and washers, in SBX/DOT and zinc borate preservative treated wood in an interior, dry environment shall be permitted. SOLID SAWN LUMBER shall meet the following minimum grades (u.n.o.) conforming to "WWPA GRADING RULES FOR WESTERN LUMBER", latest edition: BEAMS, POSTS, RA FTERS, JOIST 6X and wider DF#1 4X DF#2 2x 10 and greater DF#2 2x 8 and smaller HF#2 WALL STUDS 2x HF#2 ENGINEERED WOOD shall meet the following minimum properties: Callout E x 106 (psi) Fb(psi) Fc par (psi) Fc perp (psi) Fv(psi) GLB, 1.8E 2400 1650 650 240 All cantilevered and multi -span glue -laminated beams (GLB) shall be V8 unless noted otherwise, additionally cantilevered beams shall have zero camber. 24F-V4 shall be cambered with a 3500' radius u.n.o. LVL 2.0E 3100 3000 750 285 LSL 1.55E 1900 2050 900 310 PSL 2.2E 2900 2900 625 290 Engineered wood products shall be protected from moisture to preserve their structural integrity. Provide temporary bracing to avoid permanent deflections resulting from drying under construction dead loads. I -JOISTS Connect I -joist to plate using one 10d (0.131" x 3") nail on each side of bottom flange; drive nails at an agle at least 1 1/2" from end. Connect 1 1/4" LSL rim to I -joists with one 10d (0.131" x 3") nail into top and bottom flange. Full -depth blocking between joists over shearwalls shall be 1 1/4" min LSL. TRUSSES Manufactured trusses are a deferred submittal item designed per CODE section 2303.4 and shall be designed for all loads and load combinations per the CODE All connections per manufacturer, u.n.o. If truss layout is changed by manufacturer, please notify this office. For trusses over walls, if header is not specified over openings, design truss to span over it. See applicable detail(s): GEB WALL FRAMING & BEARING Walls shall be 2x studs at 16"oc max with double 2x top plate, and 2x base plate (exterior walls shall be 2x6 u.n.o. & interior walls shall be 2x4 u.n.o.). Block all supports solid to the foundation. See applicable detail(s): BHS TPS BEAM PENETRATIONS Allowable beam penetrations shall be made in the middle third of the span and the middle third of the depth. Contact this office for any penetration outside the allowable area. See applicable detail(s): BP POF GENERAL STRUCTURAL NOTES continued WOOD STRUCTURAL PANELS shall meet the performance standards of the "APA" DOC PS1 and PS2 for their intended application (group 5 species not allowed). SHEARWALLS are indicated on the plans with a bold dashed line and labeled SW. The following letter designation refers to the Shearwall Schedule's SHEAR FLOW CONNECTIONS / SPACING table, and the number designation refers to the WALL SHEATHING table. Multiple combinations of letter and number designations may be present. Wall Line numbers, shown inside triangles, refer to corresponding engineering calculations. Attach rated sheathing (indicated below) to 2x min STUDS spaced no more than 16"oc, u.n.o. See Shearwall Schedule for minimum thickness and fasteners (thickness at point of fastened edges governs shear values). All panel edges shall be blocked. Nail intermediate supports @ 12"oc. Do not penetrate nails past flush. Install squash blocks under the ends of all shearwalls where the framing below does not provide full bearing. Construct cripple walls same as the shearwall above, and gable -ends same as the shearwall below. Rated sheathing: 7/16" OSB rated with a 24/16 span rating. 1/2" CD with a 32/16 span rating. See applicable detail(s): SWE ROOF DIAPHRAGM Install either OSB or CD sheathing: 7/16" OSB rated sheathing with a 24/16 span rating; panel clips required when spacing is greater than 20" oc. 1/2" CD rated sheathing with a 32/16 span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Nail all boundaries and supported edges with 8d @ 6"oc and interior supports with 8d @ 12"oc, blocking not required u.n.o. ROOF -TOP DECK DIAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" cc, blocking not required u.n.o. FLOOR DIAPHRAGM Install minimum 23/32" rated Sturd-I-Floor T&G with a 24oc span rating. Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior supports with 10d @ 12" oc, blocking not required u.n.o. GARAGE FLOOR DIAPHRAGM Install minimum 1 1/8" rated Sturd-I-Floor T&G with a 16oc panel index Use 8' x 4' panels with long dimension perpendicular across supporting framing. Stagger panel rows half the long dimension. Glue and nail all boundaries and supported edges with 10d @ 6"oc and interior Top with a min of 3" concrete reinforced with 6" x 6" 10/10 wire mesh. COLLECTORS Diaphragms shall be nailed continuously to rims, drag struts, drag trusses and other collector elements at boundary spacing, u.n.o. See applicable detail(s): DTC CS CONNECTIONS and fasteners shall be per CODE Table 2304.10.1 u.n.o. The symbol, "*", indicates a hardware connector from the most current Simpson Strong -Tie Catalog. Hardware with equivilent or greater capacities from other manufacturers may be substituted, example you can use USP's Dual Specification Chart to make an equivilent or greater capacity selection. Install per the manufacturer instructions. Fasteners and hardware in contact with pressure treated wood shall be hot -dipped zinc -coated galvanized. NAILS All nails shall be "Standard Common" size per the latest edition of the National Design Specification for Wood Construction (NDS) u.n.o. HOLDOWNS See the HOLDOWN SCHEDULE. See applicable detail(s): HDN HOC POST CAPS Provide a post cap on isolated columns that most nearly matches the actual member size(s) U.N.O. Each connection shall have a minimum of (3)10d to the post and (3)10d to the beam. HANGERS Model numbers will be specified on the plans for conditions that require more than minimum capacity, otherwise see CONNECTIONS. When a hanger is not specified on the plans, use any size specific model number that fits that member. Always use MAX NAILING. Hanger to match member size. Notching or shimming of beam not allowed unless specified. JOBSITE SAFETY Sound Structural Solutions Inc has not been retained or compensated to provide design and/or construction review services related to the contractor's safety precautions or to means, methods, techniques, sequences or procedures for the contractor to perform their work. The undertaking of periodic site visits by the ENGINEER shall not be construed as supervision of actual construction and not make him responsible for providing a safe place for the performance of work by the contractor, subcontractors, suppliers or their employees, or for access, visits, use work, travel, or occupancy by any person. OWNERSHIP OF DOCUMENTS These drawings and calculations are the intellectual property of Sound Structural Solutions Inc. These drawings may not be used in whole or in part by any person without permission of Sound Structural Solutions Inc. MISCELLANEOUS The contractor shall verify dimensions and conditions at job site. The contractor shall provide temporary bracing as required until all permanent connections and stiffenings have been installed. Do not scale drawings. Pre -fabricated items to be handled and installed per manufacturer's recommendations. PLAN INSTRUCTIONS READ THIS FIRST These plans are organized so that more detailed or specific information is found in the same way by following the direction shown below: GENERAL STRUCTURAL NOTES SCHEDULES, DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES for more specific information. SCHEDULES DETAILS and PLANS will often refer to GENERAL STRUCTURAL NOTES and SCHEDULES for more specific information. DETAILS PLANS will often refer to GENERAL STRUCTURAL NOTES, SCHEDULES and DETAILS for more specific information. PLANS See the SYMBOL LEGEND as well as ABREVIATIONS AND ACRONYMS for other additional information used on the PLANS. The term, TYPICAL (or TYP), used with a detail callout or plan note, indicates that the information specified shall apply in all similar conditions. IF YOU HA VE ANY QUESTIONS OR CONCERNS CONTA CT US IMMEDIA TEL Y! We can be reached immediately by phone: (425) 778-1023 For less pressing questions, email us: inbox@ssseng.com Please help us get to your plans by having this job number handy: s2308022 ABBREVIATIONS AND ACRONYMS ABV ABOVE E.S. EACH SIDE O.C. ON CENTER A.B. ANCHOR BOLT E.W. EACH WAY P.T. PRESSURE TREATED BLW BELOW EA EACH REINF REINFORCEMENT BLK BLOCK E.N. EDGE NAILING REQD REQUIRED BLKG BLOCKING EMBED EMBEDMENT SCHED SCHEDULE B.N. BOUNDARY NAILING EXIST EXISTING SIM SIMILAR BTM BOTTOM FDN FOUNDATION STD STANDARD BRIG BEARING FLR FLOOR STRUCT STRUCTURAL BTWN BETWEEN FRMG FRAMING SW SHEARWALL CLR CLEAR FTG FOOTING THRU THROUGH CLTR COLLECTOR G.T. GIRDER TRUSS T.R. THREADED ROD CONIC CONCRETE GR GRADE TYP TYPICAL CONN CONNECTION HORIZ HORIZONTAL U.N.O. UNLESS NOTED CONT CONTINUOUS MAX MAXIMUM OTHERWISE CTR CENTER MFG MANUFACTURED VERT VERTICAL DBL DOUBLE MIN MINIMUM w/ WITH DET DETAIL o/ OVER w/o WITHOUT E. E. EACH END cc ON CENTER W.W.F. WELDED WIRE FABRIC DESIGN CRITERIA Governing Code 18 IBC Risk Category II Wind Design Data Earthquake Design Data Gravity Load Data loads are psf Dead Live Snow Rafters' •Solar-Ready3 20 0 25 Trusses (pitched) •Solar-Ready3 Pitches < 8:12 Top Chord 15 0 25 Bottom Chord 5 0 0 Floors: loads are psf Dead Live Snow Joists5 12 40 0 Decks: loads are psf Dead Live Snow Joistss 20 60 25 Notes apply as called out in table above. 1 Rafters of sawn lumber or wood I -joists. 3 Dead load includes 5psf for photovoltaic panels. 5 Joists of sawn lumber or wood I -joists. Soil Data Company: Cobalt Geosciences Date: 9/17/20 *Includes F.S. = 1.5 per Geotech Report Basic Wind Speed (3 sec gust) mph 98 Surface Roughness B Wind Exposure Category C Seismic Importance Factor, Ie 1.00 Site Classification D Short Period Acceleration, SS 1.296 1-Second Acceleration, S1 0.458 Seismic Design Category D Spectral Response Coefficient, Sps 0.864 Spectral Response Coefficient, Spl 0.562 Allowable Soil Bearing 2000 psf Passive Earth Pressure 275 *pcf Seismic Force Resisting System Seismic Importance Factor, Ie 1.00 Site Classification D Short Period Acceleration, SS 1.296 1-Second Acceleration, S1 0.458 Seismic Design Category D Spectral Response Coefficient, Sps 0.864 Spectral Response Coefficient, Spl 0.562 Allowable Soil Bearing 2000 psf Passive Earth Pressure 275 *pcf Seismic Force Resisting System Allowable Soil Bearing 2000 psf Passive Earth Pressure 275 *pcf Seismic Force Resisting System Seismic Force Resisting System Table 12.2-1: A-15 2016 Equiv. Lateral Force Procedure Response Modification Factor, R 6.5 Transverse 6.5 Longitudinal Seismic Response Coefficient, CS 0.133 Transverse 0.133 Longitudinal Seismic Base Shear, V 26051 Ibs Active Soil Pressure 35 pcf Coefficient of Friction 0.40 At -Rest Soil Pressure 55 pcf Unit Weight of Soil 125 pcf BLD2023-1286 SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc L This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---- N N O O M N �I c ra cn 0 I M %.D I.f') Internal Pressure Coefficient 0.18 Topographic Factor, Krt 2.23 Ground Elevation Factor, � 0.99 0 CITY OF EDMONDS BUILDING DEPARTMENT 2021 1111 (8)16d EVENLY SPACED, 16d @ 16" oc TYP U.N.O. TYP FACE NAILS BEAM DISCONTINUOUS #CS16 w/, DBL TOP PLATE BOUNDARY NAILS SHEATHING PER (13) 8d NAILS EA END PER NOTES NOTES POST I MIN 2x I 30° MIN 2x FLAT BLK w/ DBL ROW OF 4N -I BOUNDARY NAILS SPLICE TOP PLATE SPLICE DISCONTINUOUS DBL TOP PLATE TRUSS 2x4 BRACE @ 48"oc w/ 1435 AT BTM TPS DOUBLE TOP PLATE SPLICE GEB GABLE -END TRUSS BRACE N.T.S. TPSA N.T.S. GEBA SSS Number: s2308022 SWR DBL 2x STUD �, Project Name: EDGE NAILING SW SHEATHING C�Iron Vista - 19126 CONSTRUCT PER 94th Ave W Lot C SW-A6 Owner: HOLDOWN EMBEDDED LQH, Inc STRAP DROPPED BEAM STRAP SHOWN AROUND CORNER BOUNDARY NAILS DT 22 DIAPHRAGM TO COLLECTOR Project Location: #HTS20 MIN w/ 19126 94th Ave W, STUDS PER ROOF DIAPHRAGM MIN (7)10d x 1%" N.T.S. DTCA Edmonds, WA TO EA MEMBER HOEDOWN SCHED SW SHEATHING '._J U.N.O. EDGE NAILING 2x4 NAILER Design Professional: 2x STUD 1 BOUNDARY NAIL ALONG BOUNDARY NAIL ALONG LQH, Inc j� —L LENGTH OF COLLECTOR LENGTH OF COLLECTOR EXPOSED / 0.25d MFG TRUSS RAFTER J MAX NOTCH COLLECTOR OR RIM O #SDWS 0,152" x 6" COLLECTOR TOP PLATE HOLDOWN TO EACH RAFTER DIAPHRAGM PER 2x STUD ANCHOR STRUCT NOTES INTERMEDIATE FRAMING ABUTTING PANEL EDGES M (V CTP2 COLLECTOR TO TOP PLATE HOC HOLDOWN AT CORNER RTW RAFTER TO BEARING WALL FD7TCDIAPHRAGM TO COLLECTOR00 o N.T.S. CTPF N.T.S. HOCA N.T.S. CTPF N.T.S. DTCA J O� W Ln (V J W u MSTC Z STRAP M 4%6 HTTSKT BOUNDARY NAILS PER U ROOF DIAPHRAGM V H U TRUSS TIGHT BOUNDARY NAILS PER 6 I 2 q" AROUND RIMS ROOF DIAPHRAGM F.WL (n 2x6 TOP RIM/BLOCK EDGE NAILS Lon U) 2x6 BTM RIM/BLOCK 5 C Z STRAP MAY BE [FRH AT OPENINGS] �C,��/ = w LOCATED OLAO") #LSTA24 w/ MIN (9) -10d ON INSIDE V SHRINKAGE GAP FASTENERS PER MEMBER TOP PLATE MSTC STRAP -(A) HTT5KT- A EDGE NAILS U.N.O. EDGE NAILS, TYP SHEARWALL7#H2.5 EA END SHEARWALL GE o EA TRUSS cc pl SHEARWALL w/ TRUSS BEARING SHEARWALLS w/ TRUSS PARALLEL 3 (3)2x STUDS U.N.O. 4%" cc U) 2" 1 a11 0 SWR SHEARWALL ROOF CONNECTIONS o f _F /\r-\ 6x6 Qn COLLECTOR OR RIM STHD14 4x6 U.N.0, HDU8 U.N.O. - L-i N.T.S. SWRA STHD14- A HDU8- A DIAPHRAGM PER NAILS PER �. STRUCT NOTES SW SCHED WALL BASE #,r WALL BASE EDGE NAILS PLATE CONN, CTP1 COLLECTOR TO TOP PLATE HDN HOLDOWNS FLRRIM/BLKG PLATE CONN (SW ABOVE) (SW ABOVE) Ind N.T.S. CTPF L__J N.T.S. (OR ROOF GABLE) SOLID BLKG OR DIAPHRAGM PER COLLECTOR STRUCT NOTES -277' <,) RIM/BLKG•`#�3$� EDGE NAILS NAIL EXTENT OF EXTENT OF #A35 PER EDGE NAIL SHEARWALL SHEARWALL TPS SWF SWR PROVIDE SW SCHED ( SW BELOW) PROVIDE CRIPPLE STUD DOUBLE TOP PLATE BLKG @ 48 oc BLKG @48 oc w/ JOPARALLEL DOUBLE -SIDED SHEARWALLS, w/ JOIST -WALL INTERIOR SHEARWALLS, & PARALLEL This space reserved for governing jurisdiction stamps EXTERIOR SHEARWALLS EXT SHEARWALLS @ CANTILEVERS SHEARWALL TO FLOOR TO SHEARWALL HEADER HEADER SWF SHEARWALL FLOOR CONNECTIONS N.T.S. SWFA RECEIVED #LSTA24 w/ WINDOW OPENING Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES MIN (9) -10d x 1 / DEPARTMENT FASTENERS PER MEMBER #LSTA24 w/ MIN (9) -10d YDOOR WALL BASE WALL DIAPHRAGM U.N.O. DIAPHRAGM FASTENERS PER MEMBER U.N.O. WALL PLATE CONN PER SW SCHED DIAPHRAGM PER KING STUD SW SCHED ANCH PER STRUCT NOTES TRIMMER STUD RIM/BLKG ANCH PER COLLECTOR COLLECTOR COLLECTOR COLLECTOR 2x SILL U.N,O. SW SCHED SPLICE OPTIONAL STRAP BEAM PER SW SCHED EDGE NAILS 2x SILL U.N.O. ORIGIN DATE: 9/22/2023 LOCATION FDN FDN PER SW SCHED REVISED: �4" x 4" IS THE MAXIMUM PENETRATION CRIPPLE STUD BASE PLATE SWB SWF OR HOLE THAT CAN BE ADDED TO A SHEARWALL SHEARWALLS TO FOUNDATION SHEARWALLS TO FLOOR TO FOUNDATION 00 0 M cV �I CS COLLECTOR SPLICE SWE SHEARWALL ELEVATION SWB SHEARWALL BASE PLATE & FOUNDATION CONNECTIONS L—i N.T.S. CSAAL—i N.T.S. DRDDD N.T.S. SWBALn 0 DIAPHRAGM FLOOR JOIST FLOOR JOIST BOUNDARY PER PLAN PER PLAN NAILING 20 MIN BLOCK BOTTOM FLUSH BETWEEN JOISTS w/ BEAM 0.148"0 x 3" @ 8'0c HANGER n PERPENDICULAR FRAMING FLOOR LEDGER DIAPHRAGM BOUNDARY NAILING 2x4 MIN I / NAILER w/ �/ 1 0.1480x3 @8oc n BOTTOM FLUSH BEAM EDGE NAIL PER SW SCHED, TYP SHEATH SAME AS SHEARWALL BELOW 20 FLAT FRMG AROUND PERIMETER OF OPENING ROOF SHEATHING w/ BOUNDARY NAILS nrn ninTrr JI ILnnrvhLL FULL HEIGHT TRUSS BLOCK N.T.S. SHEARWALL ABOVE EDGE NAILS LIGHTWEIGHT CONCRETE SLAB #A35 PER SW SCHED EDGE NAILS SHEARWALL BELOW FULL HEIGHT TRUSS BLKG PER MFG MFG TRUSS TYP PER TRUSS FIG SPECS COLLECTOR SHEARWALL COLLECTOR TO SHEARWALL #SDWS 0.22"0 x 6" @ 4"0c, STAGGERED, TYP U.N.O. SOLID BLOCK BTWN JOISTS 16" MIN � � 48" MIN #CS16 TO BLOCKING DIAPHRAGM BLOCK COLLECTOR SPLICE TO BLOCKING TRUSS CLIPS, N.T.S. I I N.T.S. TYP l� BOUNDARY NAILS #H2.5A MIN @ ALL ROOF MEMBERS U.N.O. @ SHEARWALLS d Y 0.25d #SDWS 0.22" x 3" MAX SCREWS @ 16"oc NOTCH SHEAR TRANSFER TO SHEARWALL N.T.S. PROVIDE (1) STUD PER STRAP, TYP SPECIFIED NAILS PER EACH END LENGTH, TYP END LENGTH DIAPHRAGM PER STRUCT NOTES END RIM/BLKG LENGTH DIAPHRAGM PER I STRUCT NOTES #CS16 STRAP(s) END LENGTH END LENGTH #CS16 STRAP(s) BEAM, 3%" WRAP STRAP WIDE MIN. UNDER BEAM STRAP BETWEEN FLOOR STRAP TO BEAM BELOW COILED STRAP HOLDOWN N.T.S. SHEARWALL BOTTOM PLATE #PSPN58 FLOOR SHEATH PLUMBING I FLOOR #PSPN516 I I i DBL TOP PLATE DIAPHRAGM r— RAFTER 3%" MIN NOTE: BEAM SEE DETAIL SWR FOR SHEAR CONNECTIONS RCB SHEARWALL ROOF CONNECTIONS AT BEAM N.T.S. ""1 & #CS16 6)10d 1OWN STUDS REQUIRED STUDS BEAM 2x4 WALL 2x6 WALL 4x & 2-2x (SAWN) 3%x (GLB) (2) 2x4 (2) 2x6 3%x (MANF) 6x & 3-2x (SAWN) 5%x (GLB) (3) 2x4 (3) 2x6 5%x (MANF) 8x (SAWN) 63 /x (GLB) (4) 2x4 (4) 2x6 7x (MANF) GIRDER TRUSS (3) 2x4 (3) 2x6 REQUIRED TRIMMERS HEADER 2x4 WALL 2x6 WALL 4x & 2-2x (SAWN) 3%x (GLB) 2x4 2x6 3%x(MANF) 6x & 3-2x (SAWN) 5%x (GLB) ---- (2) 2x6 5%x (MANF) REQD TRIMMERS NOTE: BEAR BEAMS ON THE FULL WIDTH AND BREADTH OF THE MINIMUM SUPPORTS PER TABLES ABOVE UNLESS NOTED OTHERWISE ON THE PLANS BHS BEAM & HEADER SUPPORTS N.T.S. T&G ROOF DEC #PSPN516 w/ 8-16d NAILS INTO (2)10d @ INTERMEDIA TOP PLATE, E.S. #PSPN58 w/ END BEARING SUPPORTS PLUMBING 18d NAIL INTO 11r"BASE PLATE, E.S. SHEARWALL SHEARWALL C 1 Z' MIN 1 Z" MIN NOTCH AS REQUIRED WALL STUD, TYP A WALL STUD, TYP RAFTER PER TOP PLATE NOTCH BOTTOM PLATE NOTCH PLAN VIEW PLAN VIEW PENETRATION OF FRAMING - SHEARWALL N.T.S. FLB N.T.S. A x x x x x x---- (ING FE& TYP x % x x x ---- PLAN 9 v DBD DECK BOARD DIAPHRAGM N.T.S. 16 MAX q DEPTH d 2 4d/4 DO NOT MAKE PENETRATIONS OR NOTCHES IN THE SHADED AREA OF THE BEAM WITHOUT MIN CLEAR SPACING PRIOR APPROVAL OF THE ENGINEER SHALL BE 8x THE L/8 DIAMETER OF THE LARGER HOLE PENETRATIONS IN THIS AREA DO NOT REQUIRE APPROVAL FROM THE ENGINEER HOLES MUST BE ROUND AND ARE LIMITED TO V2"OOR%o DEPTH OF MEMBER, UNLESS APPROVED BY THE ENGINEER �L/8� L/8 T L/2 T L/8 L GLB MIN CLEAR SPACING DO NOT MAKE PENETRATIONS OR NOTCHES SHALL BE 2x THE IN THE SHADED AREA OF THE BEAM WITHOUT DIAMETER OF THE PRIOR APPROVAL OF THE ENGINEER LARGER HOLE PENETRATIONS IN THIS AREA DO NOT REQUIRE APPROVAL FROM THE ENGINEER %DEPTH DEPTH % DEPTH O 0 %DEPTH %SPAN % SPAN % SPAN SPAN SAWN DO NOT MAKE PENETRATIONS OR NOTCHES MIN CLEAR SPACING IN THE SHADED AREA OF THE BEAM WITHOUT SHALL BE 2x THE PRIOR APPROVAL OF THE ENGINEER DIAMETER OF THE PENETRATIONS IN THIS AREA DO NOT LARGER HOLE REQUIRE APPROVAL FROM THE ENGINEER %DEPTH DEPTH % DEPTH Q O DEPTH PSL & LVL HOLES PERMITTED IN MIDDLE%SPAN ONLY DEPTH LSL ALLOWED HOLE ZONE DEPTH SPAN MAX HOLE DIAMETER SHALL NOT EXCEED 2" U.N.O. MAX HOLE DIAMETER FOR LSL BEAMS SHALL BE: PSL, LVL, & LSL 3" FOR 9%" DEPTH 3%" FOR 11%" DEPTH 4%" FOR 14"-16 DEPTH BP BEAM PENETRATIONS, TYPICAL DETAIL N.T.S. SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M � N O Ln O H ' J O� W Ln N J W u z O ~ U V H Lon cUn Z Z p w O U 0) C a� U) V) U) X O S FL 42771y, o,\ This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: S211 fV 00 O 0 M Ln rn M �D HOLDOWN ANCHOR e FOUNDATION WALL MINIMUM STEM HEIGHT REQUIRED TO ACCOMMODATE ANCHORAGE PER HOLDOWN SCHEDULE FOOTING L___ THICKNESS e EMBEDDED HOLDOWN ANCHOR EMBEDDED STRAP DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN EMBEDMENTS INTO WALL MINIMUM HOLDOWN EMBEDMENT N.T.S. rnl TrC Ar n[nn STEEP, EXCAVATI( WILL ALLC STEPPED FOOTING N.T.S. MHE r- (3) 44 CANT r- SLAB 12" 12" THICKEN EDGE FOOTING N.T.S. FSLAB 1r— (2)#4 CONT 3" CLR BRIG WIDTH SOIL TSFJ THICKENED SLAB FOOTING N.T.S. TSFA 2" TYP A,B. PER PLAN 2" TYP HOLDOWN POST 2 A.B. PER PLAN 7", MIN STEM WALL SHALL BE 2'-0" DEEP MIN 1'-01I C d d a a A 17' CLC, d TYP a a a 1' Oil A. d d d . d, d (2) #4 HORIZ CONT @ TOP OF WALL tX"x3"x3" A36 BRIG PLATE w/ DBL NUT (4)#4xll 4" 8° REINFORCED FOUNDATION ANCHOR 3/4" = V-0" 2x BLOCK UNDER BEARING WALL JOIST 6-0" MAX #A34 EACH SIDE BEAM POST, TYP A24 w/ (4)10d POST (2) POWDER ACTUATED FASTENERS INTO CONIC (1" EMBED) FTG BRIG SOIL PBF2 I INTERIOR POST BEAM AND FOOTING N.T.S. FOOTING SCHEDULE CENTER UNDER CONCENTRATED LOAD U.N.O. FOOTING SIM REINFORCEMENT ID WIDTH LENGTH THICKNESS LONGITUDE TRANSVERSE (Transverse) (Longitude) F1.5 V-6" V-6" 8" (2) #4's (2) #4's LONGITUDE REINF TRANSVERSE REINF POST TO FTG THICKNESS LENGTH WIDTH (LONGITUDE) (TRANSVERSE) —� PLYNTH ON FTG FOOTING, TYPICAL N.T.S. STD 900 HOOK INTO INTERSECTING GR BEAM • • GR BEAM �nn�*•��n REINF MATCH HORIZ Z.,,REINF 1-6 CORNER BAR @ ALL OUTER REINF REINF FTG @ WALL FTG 0 WALL CORNER FTG UNDER SLAB ON GRADE STD 900 HOOK INT MATCH HORIZ �o INTERSECTING GR BEAM REINF ;--� ALTERNATE EA BAR V-6" CORNER BAR @ ALL OUTER REINF REINFORCEMENT AT INTERSECTIONS N.T.S. RIAA (2)-ROWS STAGGERED 8d MIN @ Voc FLR DIAPHRAGM FDN WALL MIN (3) - 8d TOENAILS JOIST TO SILL FLR DIAPHRAGM JOISTS FTGC MIN (3) - 8d TOENAILS BLK TO SILL FLR SHEATHING w/ 10d @ CDC TO FRMG & BLKG JOISTS 2x TIGHT -FIT BLOCKS @ 48"oc FOR (2) FULL JOIST SPACES JD JOIST DROPPED JB JOIST BEARING JP JOIST PARALLEL NOTE: METAL FASTENERS LESS THAN %" O SHALL BE HOT -DIPPED GALVANIZED WHEN IN CONTACT WITH P.T. LUMBER FTC FOUNDATION WALL TOP CONNECTIONS N.T.S. FTCA SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M (V ZO Ln O 00 O� W Ln (V J W u Z E O ~ U V H Z cn Z O� W O U pl C N U, O This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---S212 - fV V 0 00 M cV Ln Ln M k.D Ln (2) #4 CONT 8" U.N.O. @ TOP OF WALL P.T. SILL PLATE & A. B. CONIC SLAB ON GRADE CONIC STEM WALL CTRD ON FTG, U.N.O. 3'.0" MAX BETWEEN / GRADES 4'-6" MAX FINISH GRADE 24" MIN #4 VERT @ 16"oc / r #4 @ 16"oc #4 HORIZ / DOWELS w/ @ 12" oc 14" EXTENSION 18" MIN INTO WALL & STD HOOK IN FTG 16" x 8" CONC FTG, U.N.O. 3" CLR #4 LONG @ 12" oc MAX, I I I BRIG SOIL I I=1 U.N.O. (2 BARS MIN)( - NOTES: -CENTER VERTS AND DOWELS IN STEM WALL -DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN EMBEDMENTS -DEEPEN EXCAVATION TO PROVIDE MINIMUM FOOTING DEPTH FWX FOUNDATION WALL -STEM N.T.S. d D 180° 4d or 2%" MIN. BAR D #3 1 %" #4 2" #5 2 %" #6 4%" #7 5%" #8 6" FWX LEGEND d = BAR DIAMETER D = FINISHED BEND DIAMETER Note: d 1. STANDARD HOOKS SHALL CONFORM TO ACI 318 D SECTION 25.3 IO 2. REINFORCING SHALL BE COLD BENT. 12d STANDARD HOOKS N.T.S. BAR DEVELOPMENT LENGTHS BAR SIZE LAP STRAIGHT HOOK 18"18"651 t�6 24" 24" 8.25" 30" 24" 10.25" THIS IS A GRAPHICAL REPRESENTATION ONLY, THERE IS NO BEND IN THE VERTICAL BAR DOWEL w/ STD HOOK TOE BARS MUST HAVE FULL DEVELOPMENT LENGTH ON BOTH SIDES OF THIS LINE. AN EXTENDED DOWEL BAR MAY REPLACE A SEPARATE TOE BAR SHA DOWELS MAY BE 2" COVER COMBINED WITH THE @ VERT & VERTICAL AND/OR TOE DOWEL BARS PROVIDED THE DOWEL SIZE AND SPACING IS USED HEEL BARS MUST HAVE FULL DEVELOPMENT LENGTH ON BOTH SIDES OF THIS LINE CLR CLR 3" CLR TOE HEEL NOTE: THIS DETAIL IS INTENDED TO PROVIDE SUPPLEMENTAL INFORMATION TO THE FOUNDATION DETAILS PROVIDED. THE INFORMATION PROVIDED ON THOSE DETAILS WOULD SUPERCEDE THIS DETAIL. I BAR DEVELOPMENT - SUPPLIMENTAL INFO FTC FTC Z Z r P.T. SILL PLATE #4 CONT @ 24"oc w/ r 1 #4 CONT w/in I l & A.B. (1) #4 w/in I l TOP 12" OF WALL i i TOP 12" OF WALL l I I J CONIC STEM WALL — J 8 U.N.O. 8" MIN CTRD ON FTG, U.N.O, VERT & DOWELS CTRD IN STEM FINISH GRADE FINISH GRADE 8'-0" MAX VERT �' 16" MIN #4 @ 48"oc, #4 @ 48"oc FOR 8" MIN 3'-0" CORNERS & DOWELS w/ THICK WALL MAX- OR - INTO INTERSECTIONS 14" EXTENSION 18" 8'.0" 4'-0" 4' 6" MAX INTO WALL & STD MIN MAX MAX BACKFILL FOR 6" HOOK IN FTG THICK WALLS/: BACKFILL #4 AT BTM � 2" CLR ---------- CONIC FTG PER PLAN w/ 3" CLR BACKFILL (2) #4 CONT, BRIG SOIL TI U.N.O. — NOTES: _ -DETAIL PER CODE FOR SW,SP,GW,GP,GM,GC,SM,SM-SC AND ML SOILS -TEMPORARILY BRACE WALL IF BACKFILLING BEFORE BRG SOIL 1II111II I II 1 I THE TOP CONN IS CONSTRUCTED -DEEPEN FOUNDATION AS REQD TO ACCOMODATE FOR HOLDOWN ALL OTHER INFORMATION PER STANDARD EMBEDMENTS STANDARD DEEP FLOOR LATERALLY SUPPORTS TOP OF STEM FWD FOUNDATION WALL -STEM N.T.S. A B C HORIZ J IiAILKF1LL \\� ✓\\ VERT 2" COVER @ VERT & DOWEL CONCRETE WALL DOWEL w/ 900 HOOK EXTENDED TO TOE CONCRETE FOOTING r 3" COVER LONG BRIG SOIL I I I I DRAINAGE PER CODE SRW I SITE RETAINING WALL H D FINISH GRADE !rdrr�rlrrar BRIG SOIL III I � I� 11 ALL OTHER INFORMATION PER STANDARD NO LATERAL TOP SUPPORT SCHEDULE ACI 318-14 FWCBA ( 45 2000 300 0.4 8H) (BSFO SO SLO-0 AFO) DIMENSIONS H E S D A B C W (Fr -IN) (Fi-IN) (IN) (IN) (IN) IN (IN) (IN) 4-0 3-6 6 12 24 8 12 44 REINFORCEMENT *1 H DOWEL LAP VERT HORIZ LONG (Fr -IN) (IN oc) (IN) (IN cc) (IN cc) (IN cc) 4-0 #4 @ 12 20 1 #4 @ 12 #4 @ 12 #4 @ 8 *NOTES: i Clear cover requirements u.n.o. - 3" to Sol, 2" to forms in all other locations 2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL is used. FWSA N.T.S. SRWA AB C FRMG ICI HORIZ J \'IiACKI-ILL VERT 2" COVER @ VERT & DOWEL CONCRETE WALL DOWEL w/ 900 HOOK EXTENDED TO TOE a s CONCRETE SLAB / CONCRETE FOOTING 3" COVER —�=—_� III CONT 11-111 — I1 BRG SOIL II —III II -III- I DRAINAGE PER CODE FWC1 FOUNDATION WALL - CANTILEVER H D SCHEDULE ACI 318-14 FWCB ( 45 2000 0) ( S ) DIMENSIONS ID H A B C D (Fr -IN) (IN) (IN) (IN) (IN) 4 4-0 12 8 8 10 5 5-0 20 8 8 10 6 6-0 28 8 8 10 7 7-0 24 8 16 10 8 8-0 34 8 16 10 9 9-0 44 8 16 12 SO 10-0 1 44 1 10 16 12 11 11-0 1 56 10 18 12 12 12-0 62 1 10 22 14 REINFORCEMENT *1 ID DOWEL *2 LAP (IN) VERT*2 HORIZ CONT 4 #4 @ 10 32 #4 @ 10 #4 Co) 12 #4 Co) 10 5 #4 @ 10 32 #4 @ SO #4 @ 12 #4 @ 10 6 #4 @ 6 32 #4 @ 12 #4 @ 12 #4 @ 10 7 1 #5@8 40 #5916 #4@ 12 #4@ 10 8 #5@6 40 #5@ 12 #4@ 12 #4@ 10 9 #5 Ca) 5 40 #505) 10 #4@ 12 #4@9 10 #5@5 40 #5@ 10 #4@ 10 #4 Co) 9 11 #5 Ca) 4 40 #5 Ca) 8 #4@ 10 #4@9 12 #5 Ca) 4 40 #5 Ca) 4 #4910 #4@6 * NOTES: 1 Clear cover requirements (3" to soil, 2" to forms in all other locations) 2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL is used D Y LLK KEY w/ 1 STD 90 HOOK AT TOP � �•--t� HORIZ HORIZ VERT 2" CLR @ VERT & DOWEL DOWEL w/ STD 900 HOOK AND EXTEND TO TOE FWC21 CANTILEVERED FOUNDATION WALL 3" CLR SCHEDULE ACI 318-14 FWCCB ( 35 2000 275 0.4 1 SO/50 SLO.69-0.46 DIMENSIONS H D K A B C W (FT -IN) (IN) (IN) (IN) (IN) (IN) (IN) 10-0 12 34 r 36 1 10 1 8 54 REINFORCEMENT *1 H DOWEL LAP VERT HORIZ CONT KEY *2, *3 *2 (FT -IN) (IN cc) (IN) (IN cc) (IN cc) (IN cc) (IN cc) 10-0 #5@5 40 #5@10 #4@10 #4@8 #4@8 *NOTES: 1 Clear cover requirements u.n.o. - 3" to soil, 2" to forms in all other locations 2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL is used. 3 Extend the DOWEL to within 2" of the TOE edge N.T.S. FWCB �r�irar� HORIZ VERT 2" CLR @ VERT & DOWEL DOWEL w/ STD 90° HOOK, EXTEND TO TOE 2„ 2" CLR CLR HEEL FWC31 CANTILEVERED FOUNDATION WALL SCHEDULE ACI318-14 FWC-DB (NX) (45 2000 275 0.4 14H) (BFSO S50 SLO-0 AFO) DIMENSIONS H (FT -IN) E (FT -IN) S (IN) D (IN) K (IN) A (IN) B (IN) C (IN) W (IN) 10-0 10-0 0 12 N/A 22 10 50 82 9-0 9-0 0 12 N/A 18 10 44 72 8-0 8-0 0 12 N/A 16 8 38 62 7-0 7-0 0 10 N/A 12 8 34 54 6-0 6-0 0 10 N/A 8 8 28 44 5-0 5-0 0 10 N/A 8 8 18 34 REINFORCEMENT *1 H (FT -IN) DOWE3 (IN cc) LAP (IN) VERT (IN cc) HORIZ (IN cc) CONr (IN oc) TOE IN cc) HEEL (IN cc) 10-0 #5 @ 4 32 #5 @ 8 #4 @ 10 #4 @ 8 #4 @ 10 #5 @ 6 9-0 #5@6 32 #5@12 #4@10 #4@8 #4@16 #5@8 8-0 #5 @ 6 32 #5 @ 12 #4 @ 12 #4 @ 8 #4 @ 16 #5 @ 9 7-0 #5 @ 8 32 #5 @ 16 #4 @ 12 #4 @ 8 None #4 @ 10 6-0 #4 @ 6 24 #4 @ 12 #4 @ 12 #4 @ 8 None #4 @ 10 5-0 #4 @ 12 24 #4 @ 12 #4 @ 12 #4 @ 8 None None * NOTES: 1 Clear cover requirements u.n.o. - 3" to soil, 2" to forms in all other locations 2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL is used. N.T.S. FWCD HORIZ VERT 2" CLR @ VERT & DOWEL DOWEL w/ STD 900 HOOK, EXTEND TO TOE 2„ 2" CLR CLR HEEL 3" CLR FWC41 CANTILEVERED FOUNDATION WALL SCHEDULE ACI 318-14 NCDB ( 35 2000 275 0.4 7H) (BSFO S50 SLO.6-0.45 AF01 DIMENSIONS H E S D A B C W (FT -IN) (FT -IN) (IN) (IN) (IN) (IN) (IN) (IN) 11-0 9-0 24 14 14 10 44 68 REINFORCEMENT *1 H D2WE3L LAP VERT HORIZ CONT HEEL (FT -IN) (IN oc) (IN) (IN oc) (IN oc) (IN oc) (IN oc) 11-0 #5 @ 5 40 #5 @ 10 #4 @ 10 #5 @ 8 #4 @ 8 *NOTES: 1 Clear cover requirements u.n.o. - 3" to soil, 2" to forms in all other locations 2 DOWEL and VERT may be the same piece provided the size and spacing of the DOWEL is used. N.T.S. �_J N.T.S. FWCB �_J N.T.S. FWCD SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M (V O C] rl 1--1 i J O� W Ln (V J W u Z O ~ U `i ~ 0) Lon U) U) Z Z p W O U 0) C N U) V) U) X O S FL 0► . 4z 171 NAIL o,\ This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---S213 - fV C"i O 00 0 M cV UI Ln in o' M �D TOP STEM: 248.94' TOP STEM: 248.00' -MFILL, !W,I ONE Iloilo i WarmwKS7�����-Al `�� 1l0ll0 11®1I - . 11� 1 1®11®11 1r 1®11011 .I .. , , RESSIVE STRENGTH, ., � � 1®Iloll 1 1®11®11�' 1 1®� �.►1�. � :, __ 6" MIN DEPTH, TYP TOP STEM: 233.02' ,... SLAB Iloilo 11®�l0 111; � `�®11 1 10ll®11 1 1®11®11 I I®11®11 1 1®11®11 `� 1 1®11®11 1 1®11®11 l l®11®11 1 1®Ilo�' ' Iloilo Iloilo lloll0 11��' SECTION A -A N.T.S. KFILL,TyP NATIVE BEARING SOIL'W UEU I El.nIu1LHL ENGINEER TO VERIFY SECTION B-B M_ F( C 7 DETERMINING THE DEPTH OF ADJACENT FOOTINGS DISTANCE "B" SHALL NOT BE GREATER THAN DISTANCE "A" - DEEPEN EXCAVATION AS REQ'D ADJACENT FOUNDATION DEPTH FOUNDATION OR FOOTING N.T.S. I I N.T.S. AFDA SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---- LJ / \\TOP STEM: FWC BACKFILL, i NATIVE BEARING/��/��/�x��\��\\��\��\��\��\��/��/ /\ \ \ FWC2 /\/ / / R-10 RIGID INSULATION. = 60 PSI MIN COMPRESSIVE STRENGTH, �\ 6" MIN DEPTH, TYP / -_-- TOP STEM:229.52' FWC3 CONSULT — _�\ _ _ _TE GEOTECHNICAL ENGMER T — — EXCAVATION CUTS SECTION C-C F( C 1' DETERMINING THE DEPTH OF ADJACENT FOOTINGS DISTANCE "B" SHALL NOT BE GREATER THAN DISTANCE "A" - DEEPEN EXCAVATION AS REQ'D ADJACENT FOUNDATION DEPTH FOUNDATION OR FOOTING N.T.S. U N.T.S. AFDA SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M � N O Ln O 1--1 o J O� W Ln N J W u Z p O ~ U V H C1 U) p z U? Z p p w O U 0) C N U) V) �U) V X O 06. . x 42777 NAIL This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: fV C"i O 00 O M cV U, Ln cn cn Cn M LD I.f') SYMBOL LEGEND - FOUNDATION SLEXP #HOLDOWN MODEL HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. — — — CONCRETE WALL AND CONTINUOUS FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FWS, FWC1, FWC2, FWC3 or FWC4. — — — CONCRETE WALL AND CONTINUOUS FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FWX F_ -1 F2 SPREAD FOOTING See CONCRETE and REINFORCING BAR specifications per DETAIL FTG. L I 1 W%Jl\V"I iVl\ 1 [-"IY 1/4" = 1'-0" I DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M O N O 1--1 1 J O� w Ln (V sJ w z p O ~ U V H 01 U) p z U? Z p p w O U 0) C N cn V) �Ul) V X O C S F�� 06 . cis This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---- 1 0 WALL WALL WALL WALL LINE LINE L NE LINE A B C D CONCRETE PATIO 3 % x 14 LSL (1-1 #HTS30, BEAM TO STUDS 0 N GUEST BEDROOM d SW D2 HDR #HTS30, BEAM TO 46 BATH #3 WARDROBE CRAWL SPACE RAT SLAB p o> = c SW D2 #HDU11 CTS N W #HDU11 CS #HTT5KT 66 w/ (2) #A35 @ TOP (2) #A35 @ BTM FLAT 4x6, LOCATE ABOVE LOWER WINDOW #A35 TO POST, I&IWT RS 1 % x ESL (1-11) CTP1 #HTS30 BEAM TO TRIMMERS - — — — — — — — DROOPPED 5 Y x 13 YGLB (1- - - - --_ COVERED PORCH H ____ — -3) ____ HDR a a rTi//ir/ZT//i.TiiT/7/7/7z;;-f/ 7 Z, N O CS CRAWL SPACE (2) 26 STUDS SW D2 WALK-IN CTP2 1 J CJ DROPPED F— —]4x8 (1-9) CTS RAT SLAB 2x10 P,T, LEDGER w/ %" 2x10 P,T, LEDGER w/y" m #ITS TO EXPANSION ANCHOR @ 16"oc w #ITS TO EXPANSION ANCHOR @ 16"oc LEDGER #HTTSKT LEDGER — — — Q— n-----:d--------------------- ---�dn— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — -------------------G---------------- �T. rir -- e a .d. ----- °..d — —_ —_ ^ Verify expansion anchor embeddment with EOR. a - ° e. d. _ a .44 FIRST FLOOR SHEARWALLS & FRAMING ABOVE 1/4" = 11-0" (3) 2x6 STUDS 3x4 TRIMMER w/ #A34 @ TOP TO 6x8 #A34 @ BTM, TYP @ WINDOW 6x8 TOP PLATE (1-4 CONCRETE (145 pd) SLAB OVER DIAPHRAGM, 3 %" MAX THICKNESS DEAD LOAD 50 PSF MAX LIVE LOAD 60 PSF MAX SNOW LOAD 25 PSF MAX GAME ROOM IFLJ (3) 2x6 STUDS 5% x 14 PSL (1-7) W2 DROPPED DROPPED f6- DROPPED 4x�— 4x8(1-10E- L� 4'-0" 4'-0" CRAWL SPACE RAT SLAB DROPPED 4x8 (1-8F DROPPED 4x8 (1-8) F— e —-------— - ------- — 5'_011 �� 5'-01, L— 2'-3" 2x10 P.T. LEDGER w/%" #ITS TO EXPANSION ANCHOR @ 16"oc LEDGER a a----- --------- ------ (3) 26 STUDS �a (3) 2x6 STUDS ell #STHD14 ALIGN w/ STRAP ABV L (3) 26 STUDS DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M O N O 1--1 I J p w Lr) (V sJ w z O ~ U V H 0 Lon " cUn p z p w O U ''W^ 'V' ^/ 'V' ^/ V/ X O S F�� A x 42777 �<,) cis e t This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---- 0 1 fV V O 00 O M cV ul I 0 M k.D I.f') SYMBOL LEGEND SLEXP ------------------- DIAPHRAGM BOUNDARY Represents boundaries of the FLOOR DIAPHRAGM and ROOF DIAPHRAGM. POST Indicates the location of a post within walls below framing. Sizes are indicated on the plan. Grades are — — — — — — — — — — indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Consult detail BHS for posts not indicated on DIAPHRAGM PROJECTION Represents elements such as roof eaves, facades, and the like. the plans. — — — — — — — — — — SHEARWALL Represents walls which are shearwalls and shows the extents of that wall. Connections k N, N, \ \ INTERIOR BEARING WALL Indicates interior walls which support repetitive members. Construct per WALL per the SHEARWALL SCHEDULE. FRAMING & BEARING in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. #HOLDOWN MODEL J I L LIJ HOLDOWN Represents holdowns which are located at the bottom of the wall where it is called out. Connections are HANGER Indicates hanger, standard or concealed flange. Provide fasteners in all holes. Reference the GENERAL wall-to-wall or wall -to fdn u.n.o. Connections per the HOLDOWN SCHEDULE. STRUCTURAL NOTES for the minimum size hanger. If a different model no. is required, it will be noted on the plan. BEAM or HEADER Represents the location of a beam or header. Sizes are indicated on the plan. Grades are JOIST, TRUSS, OR RAFTER Repetitive member symbol points in the direction of the span. The type, size and max indicated in the GENERAL STRUCTURAL NOTES, U.N.O. on the plan. Headers (HDR) shall be 4x8 DF #2 at dropped spacing between members will be indicated in bold type with a symbol which is representative of the layout of the condition u.n.o. Flush headers (FRH) shall be 2-1 %4 x 14 LSL RIM at joists u.n.o. Reference detail FRH for entire level. installation of the flush rim header. WALL WALL WALL WALL LINE LINE LINE LINE A R C D I> SECOND FLOOR SHEARWALLS & FRAMING ABOVE 1/4" = V-0" DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS TOP � BTM TRIMMERS SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M � N O Ln O 1--1 o J O� W Ln N J W u Z O ~ U V H C1 U) p Z U? Z p w O U pl U) V) U) x O A 42771 f NAIL This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---- 1 1 Ln FJ> WALL fB TC WALL NE LINE A D THIRD FLOOR SHEARWALLS & FRAMING ABOVE 1/4" = V-0" DO NOT SCALE - REFER TO ARCHITECTURAL SHEETS FOR DIMENSIONS %" SCREWS SSS Number: s2308022 Project Name: Iron Vista - 19126 94th Ave W Lot C Owner: LQH, Inc Project Location: 19126 94th Ave W, Edmonds, WA Design Professional: LQH, Inc M � N O Ln O 1--1 o J O� W Ln N J W u Z p O ~ U V H C1 U) p z U? Z p p w O U pl C N cn V) U) X O S F�� 06 42771 q I NAIL This space reserved for governing jurisdiction stamps RECEIVED Oct 25 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ORIGIN DATE: 9/22/2023 REVISED: ---- 1 2