Loading...
REV1 APPROVED-BLD2023-1530+Architectural_Plan+6.12.2024_12.46.11_PM+4317498SIDING PER ELEVATION OVER APPROVED WATER RESISTANT BARRIER 2x6 STUDS @ 16" O.C. SHEATHING & NAILING INSUL. PER ENERGY NOTES PER SHEARWALL SCHEDULE %" GYPSUM BOARD 2x BASE PLATE 2-16d EA. STUD PT SILL PLATE, ANCHOR BOLTS 3Y2" CONC. SLAB OVER 4" BASE. & WASHERS PER ENGINEER FILL & COMPACT AS REQUIRED z SEE STEM z 2" RIGID FOAM R-101NSUL. WALL DTL PER ENERGY NOTES. BEVEL Is 00 FOAM FORTH ERMAL BREAK IF REQ'D. 4" TIGHTLINE TO PER IRC 405.1 CONNECT DOWNPOUTS. FOOTING DRAIN ONLY REQ'D SEPARATE FROM FOUND. DRAIN WHERE FOUNDATION WALLS ENCLOSE USABLE SPACE SLAB FLOOR — STEM WALL DTL SCALE: %" = V-0" c Lr Taherza� � woe WASy,N /j to), 21 r a`v� �S7()NA L EXPIRES FEB 2025 STRUCTURAL ONLY rQl_nil ULLJLVL%J- I %J%JV GENERAL NOTES OPERABLE WINDOWS WITH OPENINGS GREATER THAN 72" ABOVE GRADE OR SURFACE BELOW LOWEST PART OF CLEAR OPENING TO BE 24" MIN. ABOVE FINISHED FLOOR. EXCEPTIONS: FULLY OPEN WINDOWS WHERE A 4" SPHERE MAY NOT PASS THRU OR WHERE FALL PROTECTION DEVICES ARE PROVIDED PER ASTM F 2090 OR IRC R312 SAFETY GLASS & SKYLIGHTS PER IRC R308 ALL HOLDOWNS, FRAMING ANCHORS & SHEARWALL NAILING TO BE INSPECTED BEFORE COVERING OSLAB -ON -GRADE INSULATION R-10 RIGID WATER RESISTANT FOAM INSULATION RATED FOR GROUND CONTACT. EXTEND 24" VERTICALLY OR HORIZONTALLY AROUND PERIMETER OF SLAB -ON -GRADE. PROTECT ALL EXPOSED ABOVE GRADE EDGES OF INSULATION FROM MOISTURE & DAMAGE. MAINTAIN A THERMAL BREAK AT THE EDGE OF SLAB. PER ENERGY CREDIT 1.3 - INSULATE UNDER ENTIRE SLAB FOOTING SCHEDULE CALL OUT H x W x D REQD REBAR 12 6x12x12 15 7x15x15 18 8x18x18 20 8x20x2D 24 8 x 24 x 24 3 - #4 EA. WAY 30 10 x 30 x 30 4 - #4 EA. WAY 36 10x36x36 4-#4EA. WAY 42 12 x 42 x 42 4 - #4 EA. WAY 18C SEE DTL N-S2 SEE DTL N-S2 ALL EXTERIOR FOOTINGS TO EXTEND 18" MIN. BELOW FINISHED GRADE UNLESS NOTED OTHERWISE. STRIP ALL WOOD FORMS PRIOR TO BACKFILLING. REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eris. Cswter LEGEND: IEPRESSSTEM HEIGHT: - 911 TND STEM HEIGHT: 352.001 BUILDING OFFICIAL Jun 13 2024 APPROVED DATE REVISION Jun 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT JI 0 N PLAN SCALE: %" = V-0" APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION m CD 0 00 M N U_ N LU W Q Q = 2 l~O�N Lr' w � m w w � Y v J Q W N W z O O 0 N LLJ C00 D Cjl Q o o 00 c/) m p � z (D (f� O LLJ o - w o Q rN N O w 0 r m N LLJ °00 O 1� 1-29-23 CR E 0 E 0 U w m o: (2)2x STUDS @ HOLDOWN 2x4" P.T. MUDSILL w/ ANCHOR BOLTS PER PLAN 12" MIN. AT MUDSILL ENDS AND JOINTS, WITH 7" MIN. EMBEDMENT. (U.N.O.) SEE SCHEDULE PYL. EDGE NAILING TO EACH STUDS @ HOLDOWN CONT. PLY. TO SILL PLATE 16d @ 4" O.C. 8d @ 6" O.C. EDGE NAILING PER SCHEDULE FLOOR JOISTS (PER PLAN) SIMPSON STHD14RJ w/ EDGE NAIL 38-16d SINKERS TO DBL. STUDS FINISH (STRAP LOCATION GRADE PER PLAN) (2) #4 BARS TOP CONTINUOUS #4 @ 16" O.C. VERT. @ CENTERLINE OF WALL #4 @ 10" O.C. HORZ. 10 MIL. 'BLACK' VISQUEEN VAPOR BARRIER. 48" MAXIMUM I UNYIELDING UNBALANCED (2)#4 CONT. 5" 6" 5„ A EXTERIOR SHEARWALL s1 @ CRAWL SPACE 3/4"=1'-0" X Q 00 00 PLY. EDGE NAILING 2x SILL PLATE w/ %" '@ HOLDOWN STUD ANCHOR BOLTS OR EXPANSION BOLTS PER (2)2x STUDS SCHEDULE STHD14 w/ 38-16d (2) #4 CONT. (TYP SINKERS NAILS NA I STRAP LOCATION EXPANSION L4--i PER PLAN JOINT/ THERMAL EDGE NAILING BREAK v FINISH 1=1I1=1I1=1I1=1I1=1 i I _ 00 GRADE -III AI I I I -I I I -I I I- 1=1 I I -III -III -I I' X o #4 @ 16" O.C. VERT. I ° III -III -III= z a 0 1= b I I-1 I I -III -I' Q #4 @ 10" O.C. HORZ. - ° I I I -I I I -III - - Q Y 1=1 � . 11=1 11=1 11- 00 00 m z m 1 STANDARD HOOK(TYP.) 48" MAXIMUM [511 6" 5" UNBALANCED E� EXT. SHEARWALL @ 3/4"=1'-0" FLOOR PL) FLOOR JOIN (PER PLAN (2)#4 CONT. SLAB EXTERIOR WALL PLYWOOD PER SCHEDULE BOTTOM PLATE NAILING PER SCHEDULE EDGE NAILING PLY. SPLICE CONT. RIM EDGE NAILING PLY. PER SCHEDULE JOIST PERP. TO EXT. WALL 3 4)1=1 -0 11 (2)2x STUDS @ HOLDOWN 2x P.T. MUDSILL w/ ANCHOR BOLTS PER PLAN 12" MIN. AT MUDSILL ENDS AND JOINTS, WITH 7" MIN. EMBEDMENT. (U.N.O.) SEE SCHEDULE (2) LAYERS 15# FELT @ STEM WALL TO DEPTH OF JOIST FLOOR JOISTS (PER PLAN) TOP FLANG HANGER o #4 BARS TOP v J CONTTIN11UggOUppSCC ER Q 4CENTERLINE' OVF 1 Z Q #4 @ 10" O.C. HOR m 6 MIL. 'BLACK' VISQUEEN VAPOR BARRIER. BOTTOM PLAT PER SCHEDUL FLOOR PLYWO FLOOR J (PER PL PYL. EDGE NAILING TO EACH STUDS @ HOLDOWN CONT. PLY. TO SILL PLATE SIMPSON STHD14 w/ 38-2 1/2x. 148 NAILS TO DBL. STUDS (STRAP LOCATION PER PLAN) 12d @ 3 O.C. 8d @ 6" O.C. EDGE NAILING PER SCHEDULE ' FINISH - GRADE c° °I x z Ld Q I � ZJ TALL ° bo. I- o m ?. �- C-3 � z Q Dm I° - ' 00 _ UNYIELDING SOIL 5 6' (2)#4 CONT. EXTERIOR SHEARWALL @ CRAWL SPACE 3/4"=1'-0" SIMPSON H1 EA. END/EA. TRUSS PLY. EDGE NAILING 2x VENT BLK'G. w/ 1Y2"0 VENT HOLES (AS REQ'D. PER ARCH.) w/ (2)16d TOE NAILED @ EA. TRUSS/ EA. END EDGE NAILING WALL SHT'G. PER SCHEDULE EAVE @ ROOF (TRUSS 3/4"=1'-0" 8d @ 6 ROOF F 2x VEN BLK'G EDGE NAIL PLYWD SCHEDI DOUBLE PORTAL FRAME ° ° ° ° ° ° ° I° ° 3 1/2"x11 1/4" MIN. HDR. I° (BUILT-UP, SOLID SAWN, LGL, ETC.) ° o°- u1 L° FASTEN T.PL. TO HDR. W/ 2 ROWS OF 16D SINKERS @3" ox. (TYP.) 2400 LB HDR. STRAP OPPOSITE SHEATHING AS SHOWN SEE SECTION A -A) (TYP. 1°11° (MSTA24) X a °11°11 °1°I I° FASTEN SHEATHING TO HDR. W/ 8D COMMON °1°1 NAILS IN 3" GRID PATTERN AS SHOWN AND 3" ox. o 1 °1°1 1°1 1.1. IN ALL FRMNG. (STUDS & SILLS) TYP. 0 °°---------- FOR FRAMES OVER 8", PANEL SPLICE (IF NEEDED) SHALL OCCUR WITHIN 24" OF MID -HEIGHT. BLOCKING IS REQUIRED. IF 2X_ BLOCKING IS USED THEN IT MUST BE STITCH NAILED W/ 1 ROW OF 16D SINKERS " 3500 LB HOLD DOWN STRAP APPLIED 11 OVER SHEATHING INSTALLED IN CONCRETE PER MANUFACTUREERS INSTRUCTION (STHD14) °1 - °Io � -To 0 oTo °1 �- ° °T° °r° ° (2) 5/8" DIA. ANCHOR BOLT W/ 7" MIN. a i° EMBEDMENT @ 8" o.c. & 3"x3"x1/4" PLT. WASHER la I L_ ai L_ a I I ° I' I L° a a a a aa a 16"W x 8"T CONT. FT'G. °12"x16" CONT. I w/(2) #4 CONT. w/ (2) #4 BAR CONT., @ TOP & BOTTOM EXTEND TO FAR (TYP.) SIM. DETAIL E/S1 FACE OF CONC. HOOK ENDS (TYP.) FRONT ELEVATION MIN. LATERAL PANEL 3 4 =1 -0 py 8d @ 6" O.C., TYP. PLY. w/ EDGE NAILING TRUSS DRAG m STRUT PER w o_ RAFTERS @ " � PLAN DESIGN O.C. N z A35 CLIP @ 16" FOR 300#/FT v)z O.C. TRUSS TO LATERAL LOAD 4PSON H2.5 DBL. PLATE IP @ EA. FTER III 2x BLK'G. @ 24"o.c. w/ A35 EDGE NAIL EA. END EAVE @ STICK -FRAME ROOF EXT. WALL SHEATHING PER SCHEDULE EDGE NAILING PLY. SPLICE EDGE NAILING CONT. RIM EDGE NAILING EXTERIOR WALL JOIST PARALLEL TO EXT. WALL 3 4"=1 7-0" LSL RIM J❑IST- 0 cV CS16 STRAP/ FILL ALL HOLES w/ 8d NAILS 0 N PLY. PER SCHEDULE DRAG STRUT TRUSS (1)2x STUDS @ EA HOLDOWN J❑IST PER PLAN (1)2x STUDS @ HOLDOWN STRAP HOLDOWN AT FLOOR 3/4"=1'-0" SEE PLANS FOR # OF HOLD-DOWNS SHEARWALL P BOTTOM PLAT PER SCHEDUL EDGE NAILING FLOOR PLYWO JSTS PER PLf SHEATHING FILLER IF NEEDED °I ° ° ° ° ° I ° 2400 LB ° I ° ° ° ° ° ° 1° HDR. o-a -----X STRAP III II (MSTA24) IJI I I 16D 1. SINKERS 11 21$ROWS @ 3 o.c. TYPICAL POST FRAME CONSTRUCITON °11°1- - --- ---- ° O a- ° --° 01°1 7/16"MI THICKNESS I K 2x FRAMING WOOD STRUCTURAL PANEL o Too .1. I I al I° I I a a i__J 16"W x 8"T CONT. ° A FT'G. w/ (2) #4 BAR CONT., (TYP.) SIM. DETAIL E/S1 SECTION A -A A -A SIDE ELEVATION ONE STUD @ EACH SPLICE (T` PLATE STUDS NOTE: SPLICE AND NAIL TOP PLATES AS SHOWN @ ALL EXTERI❑R WALLS, SHEAR WALLS, & AT EACH FLOOR LEVEL AND AT ROOF, DBL. TOP PLATE SPLICE 3/4"=1'-0" ...v�iv uuiJ SHEARWALL PERPENDICULAR TO FLOOR JOISTS SHEARWALL PI BOTTOM PLATE PER SCHEDULE EDGE NAILING FLOOR PLYWO( JSTS PER PLA P 6" O.C. __._. BEAM PER PLAN SHEARWALL PARALLEL TO FLOOR JOISTS INTERIOR SHEARWALL TO FLOOR BELOW 3/4"=17-0" REVISION Jun 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT SHEARWALL SCHEDULE: SW_6 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 6"o.c. ALL EDGES & 12"o.c. FIELD. 2. BOLT SILL PLATE TO CONCRETE w/ 5/8 0 x 10" ANCHOR BOLTS @ 48"o.c. 3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 4"o.c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER DETAILS AS PROVIDED. SW-4 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 4"o.c. ALL EDGES & 12"o.c. FIELD. 2. BOLT SILL PLATE TO CONCRETE w/ 5/8 0 x 10" ANCHOR BOLTS @ 32"o.c. 3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 3"o.c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER DETAILS AS PROVIDED. SW-3 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 3"o.c. ALL EDGES & 12"o.c. FIELD. 2. a. BOLT (3)2x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR BOLTS @ 16"o.c. PER DETAIL D/S1 2. b. BOLT 3x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR BOLTS @ 16"o.c. 3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 4"o.c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER DETAILS AS PROVIDED. 5. USE 3x OR (2)2x @ ALL FRAMING MEMBERS RECEIVING END NAILING FROM ABUTTING PANELS. SW_2 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 2"o.c. ALL EDGES & 12"o.c. FIELD. 2. BOLT 3x SILL PLATE TO CONCRETE w/ 5/8 b x 12" ANCHOR BOLTS @ 16"o.c. 3. FASTEN DOUBLE BOTTOM PLATE TO FRAMING BELOW w/ 2-LAYERS 16d @ 3"o. c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE w/ SIMPSON LTP4 @ 10"o.c. PER DETAILS AS PROVIDED. 5. USE 3x OR (2)2x @ ALL FRAMING MEMBERS RECEIVING END NAILING FROM ABUTTING PANELS. TYPICAL ROOF SHEATHING: 7/16" O.S.B., INDEX 40/20, UNBLOCKED, w/ FACE GRAIN PERPENDICULAR TO FRAMING BELOW. NAIL AS FOLLOWS: DIAPHRAGM BOUNDARY, OVER EXTERIOR WALLS, SHEAR WALLS, & DRAG STRUTS: 8d @ 6"o.c. ALL SUPPORTED EDGES: 8d @ 6"o.c. FIELD: 8d @ 12"o.c. TYPICAL FLOOR SHEATHING: 3/4" T&G O.S.B., INDEX 40/20, UNBLOCKED, LAID UP w/ FACE GRAIN PERPENDICULAR TO FRAMING BELOW, STAGGER END JOINTS, GLUE & NAIL AS FOLLOWS: DIAPHRAGM BOUNDARY, OVER EXTERIOR WALLS, SHEAR WALLS, & DRAG STRUTS: 8d @ 6"o.c. ALL SUPPORTED EDGES: 8d @ 6"o.c. FIELD: 8d @ 10"o.c. NOTES: 1. USE 3%3"x1/4" PLATE WASHERS ON ALL ANCHOR BOLTS. 2. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE(S) w/SHEATHING PER NDS 2018 EDITION (SDPWS) 4.3.6.4.3. 3. EXPANSION BOLTS MAY BE USED IN LIEU OF ANCHOR BOLTS w/ SAME SPACING & 4 1/2"min. EMBEDMENT. 4. ALL POWDER DRIVEN NAILS SHALL BE 2 3/4" LONG(min.) x 0.156 SHANK 0. w/ MINIMUM 1 1/4" PENETRATION. 5. USE 20d NAILS @ 3x FRAMING MEMBERS. 6. a. 8d NAILS SHALL BE .131 x 2 1/2" LONG b. 10d NAILS SHALL BE .148 x 3" LONG C. 16d NAILS SHALL BE .162 x 3 1/2" LONG d. 20d NAILS SHALL BE .192 x 4" LONG SPECIAL INSPECTION PROGRAM ESTABLISHED PER CHAPTER 17 OF THE 2018 IBC, UNLESS NOTED OTHERWISE ALL SPECIAL INSPECTIONS SHALL BE CONTINUOUS, UNLESS NOTED OTHERWISE TYPES OF WORK PERIODIC CONTINUOUS COMMENTS SOILS: REF. PROJECT SPECIFICATIONS GRADING, EXCAVATION, & FILL REF. PROJECT SPECIFICATIONS DRILLED PIERS CONCRETE: PLACEMENT OF REINFORCING STEEL BOLTS CAST IN CONCRETE PLACING OF CONCRETE > 2,500 psi SPECIAL CASES: SHEAR WALL NAILING WOOD DIAPHRAGMS ADHESIVE ANCHOR INSTALLATION X PER ICC-ES EVALUATION REPORT EXPANSION BOLT INSTALLATION PER ICC-ES EVALUATION REPORT HOLD DOWNS &STRAPS PER FOOTNOTE #5 SPECIAL INSPECTION PROGRAM FOOTNOTES: 1. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. 2. SPECIAL INSPECTOR SHALL BE HIRED BY THE PROJECT OWNER. 3. DUTIES OF THE SPECIAL INSPECTOR INCLUDE, BUT ARE NOT LIMITED TO: A. ACKNOWLEDGE THE SPECIAL INSPECTION PROGRAM & THE SPECIAL INSPECTION AND TESTING AGREEMENT, PROVIDED BY LOCAL JURISDICTION. B. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK FOR CONFORMANCE WITH THE APPROVED PERMIT PLANS & SPECIFICATIONS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE ENGINEER & TO THE BUILDING OFFICIAL. C. FOR EACH INSPECTION, THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, ARCHITECT, ENGINEER, CONTRACTOR, & OTHER DESIGNATED PARITIES IN A TIMELY MANNER. D. THE SPECIAL INSPECTOR SHALL FURNISH A FINAL REPORT STATING WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS INSPECTED, & WHETHER SAID WORK WAS IN CONFORMANCE WITH THE APPROVED PERMIT PLANS & SPECIFICATIONS, & THE APPLICABLE WORKMANSHIP PROVISIONS OF THE STATE OF WASHINGTON. 4. DUTIES OF THE CONTRACTOR INCLUDE, BUT ARE NOT LIMITED TO: A. NOTIFY THE SPECIAL INSPECTOR AT LEAST 24 HOURS IN ADVANCE THAT THE WORK TO BE INSPECTED IS READY FOR SUCH INSPECTION. B. ENSURE THAT ALL WORK REQUIRING SPECIAL INSPECTION REMAINS ACCESSIBLE & EXPOSED UNTIL IT HAS BEEN OBSERVED & INDICATED TO BE IN CONFORMANCE BY THE SPECIAL INSPECTOR, & APPROVED BY THE BUILDING OFFICIAL. C. PROVIDE THE SPECIAL INSPECTOR WITH ACCESS TO APPROVED PERMIT PLANS & SPECIFICATIONS AT THE JOBSITE. D. MAINTAIN AT THE JOBSITE COPIES OF ALL REPORTS SUBMITTED BY THE SPECIAL INSPECTOR. 5. ALL SPECIAL REQUIREMENTS FOR SEISMIC & WIND RESISTING SYSTEMS AS REQUIRED BY IBC SECTION 1704.3.2 & 1704.3.3. . It U"' o� Z� (.0 N >Q j � 0 ) m J LID �U' Y CN I..L 2 W Y X cD W z � Z� � N m O M W rI� O N m v � N � (D°° Z N W0�� W _ co CO�- N REVISED PLAN APPROV D CITY F EDMONDS BUILDING DIVIS ION r�& Jun 13 2024 `��aher2a vOF WASly y� LI 9 z STEA5) l's IO NA L 1 NC / Project Project No. Drawn By Date 08-28-2023 Sheet si 12%18" PLOT = 1/2 SCALE E 0 U N N w FLOOR PLYWOOD FLOOR JOIST EDGE NAILING SHEARWALL PER 8d @ 4' ❑.C.' PLY. TO BLOCKS (2)A35 CLIPS (2)2x6 BLOCK O.C. EDGE NAIL. 8d @4"o.c. FLOOR PLYWOOD BLOCKING FLOOR JOISTS (PER -PLAN) EDGE NAILING SHEARWALL PER PLAN A35 @ 12"o.c. SHEARWALL PARALLEL TO FLOOR J❑ISTS SHEARWALL PERPENDICULAR TO FLOOR J❑ISTS NT. SHEARWALL TO FLOOR ABV. N.T.S. 0 a �0 0 8'-0» (6) 16d BRACE TO BLOCK (2) 2x6 DIAG❑NAL 'T' BRACE ' @ RIDGE AND @ 10'-0' D.C. MAX. (VERIFY w/ TRUSS MFGR.) 2x6 CONT. 16d @ 6' D.C. 2x6 CONT/ TO TOP PLATE TYP. GABLE TRUSS DETAIL 3/4"-17-0" 2x @ 16"o.( (TYP. PLY PEI SCHEDULI E.� BEAM PER PLA E.� (TYP.) UPSET BEAM @ FLR. _AN T PER AN 2x TRUSSES @ 24' D.C. 2x ❑UTRIGGER (❑PTI❑NAL) EGDE NAILING DBL. TOP CHORD H❑RZ, WEB BRACING BY TRUSS MFGR. PER T.P.I. SPECS. NAIL TO ALL TRUSSES 16ci @ 6' D.C. (2)2x6 CONT. @ GABLE -END TRUSS MID HEIGHT STRUCTURAL TRUSS w/ 2x4 FLAT INLET STUDS @ 24' D.C. (2)A35 CLIPS (ONE EA. SIDE) 16d @ 6' D.C. (TRUSS TO 2x6) EDGE NAILING 7/16' O.S.B. OR 1/2' PLYWOOD EDGE NAIL. 8d @ 4"o.c. EDGE NAILING END RAFTER EDGE NAILING A -zr, (, , a"o.c. _YWOOD SHT'G. RAFTERS PER PLAN E.N. @ (2) SIDE PLYWD. SHEARWALL PER PLAN EXT. SHEARWALL TO ROOF ABV. N.T.S. BOTTOM > NAILING PER SCHEDULE RIM JOIST PER PLAN FLOOR PLYWD IVI IVI InI InI JOIST PER PLAN DIRECTION VARIES 4 1/2" EMBEDMENT ® EXP. BOLTS PER SHEAR WALL SCHEDULE SLAB PER\ PLAN \ UNYIELDING SOIL DECK LEDGER NO PAVERS SHEATHING PER SCHEDULE PT PLATE W/ AB'S OR EXP. BOLTS PER SCHEDULE EDGE NAILING (2) #4 CONT 1'-6" TOP&BOTTOM THICKENED SLAB EXTERIOR WALL PER PLAN EDGE NAILING DECK PLYWD JOIST HANGER �(SIMPSON "U" HANGER) DECK JOIST PER PLAN SIMPSON DTT2Z ® 8'-0" O.C. AND AT EACH END TO DBL JOIST w/ 1/2" dia x 3 1/2" LONG LAG SCREW TO (E) DBL TOP PLATE PT 2x10 LEDGER W/ (4) 16d ® 12"o.c. AND (1) 1 /2"dia LAG SCREW @ 12"o.c. STAGG. EDGE NAILING EXTERIOR WALL PER PLAN EDGE NAIL ^' " TO STUD STUDS HOLDOWN PER PLAN SIMPS❑N CS16 STF FILL ALL HOLES 8d NAILS MULTIPLE JOISTS BEND AROUND BEAM PER PLAN STRAP HOLDOWN AT HDR 3/4"=1'-0" SEE PLANS FOR # OF HOLD—DOWNS 2x6 BLOCKING W/ 16D AT 6"OC EDGE NAILING HANGER EACH TRUSS TO LEDGER PREMANUFACTURED ROOF TRUSSES PER PLAN ROOF DIAPHRAGM ROOF SHEATHING PER NAILING PER STRUCTURAL NOTES STRUCTURAL NOTES 8d @ 6" O.C. 2x4 BLOCKING, RBC @ 24"o.c, VENT BLOCKS AS REQ'D PER PLAN SIMPSON H1 EA. TRUSS POST CAP PLAN - POST OR WALL PER PLAN HANGER ' 2x8 LEDGER w/ (3)16d 16"o.c. EA STUD BEAM OR DBL. TOP PLATE TRUSS TO WALL 8c LEDGER TO WALL 2x8min. LEDGER 16"o.c. EA S' 6"o.c. TO 2X CONT. WALL SHE PER SCHEDULE 8d@4"o.c. EDGE NAIL PLY. TO EACH TRUSS ROOF TRU S DESIGN FOR 300# FT OF LATERAL OAD (4)12d TO 2x4 FLAT TO TOP PLT. 2x4 FLAT @ 12" O.C. (2)16d IEDULE ROOF TRUSS PARALLEL TO S.W. 3/4"=17-0" 3/4"=1'-0" TT5 HOLDOWN NCHOR FILL ALL OLES w/ 10d AILS 2)2x STUDS DGE NAILING PLY. 0 EACH DOUBLE ;TU D /8" DIA. THREADED ;OD IN SIMPSON PDXY-(SET22XP) ADHESIVE SYSTEM OR QUIV. PER MFG. ECOMMENDATION :ONC. FOUNDATION (MAY BE USED IN LIEU OF MISSED STHD14's SPECIAL INSPECTION REQUIRED) R_'TYP. HTT5 HOLDOWN 3/4"=l'—O" (WET —SET APPLICATION) NAILING BLOCKING 6D AT 6"OC HTT5 HOLDOWN ANCHOR FILL ALL HOLES w/ 10d NAILS (2)2x STUDS EDGE NAILING PLY. TO EACH DOUBLE STUD SIMPSON SSTB20 )NC. FOUNDATION REVISION Jun 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ co U o� �r- Z (0 Q � 0 r ) v m � L0 � J Q ' W W w z LL N Z oo � C: CO W r I"� O N m `f a N � � a0 Z O LO W5�E W r M CO N W H � N 7j co -4-0 M L A--+ U L -4--+ RE ISED PLAN APPRO E CITY OF EDMONDS BUILDING DIVI 31014 rt,,- BUILDING OFFICIAL Jun 13 2024 Taherza� OV WAsyN�e� 2i r , V �s'S"0NAL��C�`� Project Project No. Drawn By Date 08-28-2023 Sheet S2 12%18" PLOT = 1/2 SCALE m 2. GENERAL STRUCTURAL NOTES (The following applies unless specifically indicated otherwise on the plans.) ALL MATERIALS & WORKMANSHIP, DESIGN, & CONSTRUCTION SHALL CONFIRM TO THE REQUIREMENTS OF THE DRAWING SPECIFICATIONS, INTERNATIONAL BUILDING CODE, 2018 EDITION. DESIGN CRITERIA ROOF LIVE LOAD (SNOW) 25 psf SPRINKLERS 2.0 psf (IF APPLICABLE) FLOOR LIVE LOAD (RESIDENTIAL) 40 psf FLOOR LIVE LOAD (DECK) 60 psf (1.5x AREA SERVED) HANDRAILS & GUARDS RAIL LINE LOAD: 50 psf RAIL CONCENTRATE LOAD: 200# STAIR & CORRIDOR LIVE LOAD 100 psf MECHANICAL UNITS WEIGHTS AS FURNISHED BY MFG. WIND 100mph (BASIC WIND SPEED) EXPOSURE 'B' (RISK CATEGORY II) Kzt = 1.20 EARTHQUAKE SS=1.60 S1 =.57 (CLASS 'D') LIGHT FRAMED SHEAR WALL R=6.5 ALLOWABLE SOIL PRESSURE 1,500 psf. (NATURAL SOILS or COMPACTED) SEE PLANS & COMPUTATIONS FOR ADDITIONAL LOADING CRITERIA PER I.B.C. SECTION 1603 & SECTION 1607 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION w/ ARCHITECTURAL DRAWINGS FOR BIDDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS & CONDITIONS FOR COMPATIBILITY & SHALL NOTIFY THE ARCHITECT & STRUCTURAL ENGINEER, OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION TO ALLOW ARCHITECT & ENGINEER TO COMPLETE PROPER REVISIONS TO THE WORK. 4. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED & IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 psf. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, & CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING (e) CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY & MUST BE FIELD VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SHORING FOR THE STRUCTURE & STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS & THE METHODS, TECHNIQUES, SEQUENCES & PROCEDURES REQUIRED TO PERFORM HIS WORK. 7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT & THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL & TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW & APPROVAL BY THE ARCHITECT & STRUCTURAL ENGINEER. 9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED, SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE & ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. 10. SHOP DRAWINGS FOR STRUCTURAL STEEL, GLUED LAMINATED MEMBERS, OPEN WEB WOOD TRUSSES, & PLYWOOD WEB JOISTS SHALL BE SUBMITTED TO THE ARCHITECT & STRUCTURAL ENGINEER FOR REVIEW TWO WEEKS PRIOR TO FABRICATION OF THESE ITEMS. 11. SHOP DRAWINGS REVIEW: DIMENSIONS & QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, & THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW & STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. SUBMISSIONS SHALL INCLUDE A REPRODUCIBLE & ONE COPY; REPRODUCIBLE WILL BE MARKED & RETURNED. SHOP DRAWINGS SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, THAT HE DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH MATERIAL HE INTENDS TO FURNISH & INSTALL & BY DETAILING THE FABRICATION & INSTALLATION METHODS HE INTENDS TO USE. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS & THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS & SPECIFICATIONS SHALL CONTROL & SHALL BE FOLLOWED. GEOTECH N I CAL 12. FOUNDATION NOTES: SUB -GRADE PREPARATION INCLUDING DRAINAGE, EXCAVATION, COMPACTION, & FILLING REQUIREMENTS, SHALL CONFORM STRICTLY WITH RECOMMENDATIONS GIVEN IN THE SOILS REPORT OR AS DIRECTED BY THE SOILS ENGINEER. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL or BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON PLANS (or IN DETAILS) ARE MINIMUM & FOR GUIDANCE ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD WORKING WITH THE TESTING LAB & SOILS ENGINEER. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING GRANULAR FILL & PROVIDE FOR SUBSURFACE DRAINAGE. STRUCTURAL FILL: AS APPLICABLE PER SITE CONDITIONS OR AS DIRECTED BY THE SOILS ENGINEER. FOLLOW ALL RECOMMENDATIONS & SPECIFICATIONS AS GIVEN PER THE SOILS REPORT. CONCRETE 13. CONCRETE SHALL ATTAIN A 28 DAY STRENGTH OF f'c= 2,500 psi & MIX SHALL CONTAIN NOT LESS THAN 5 1 /2 SACKS OF CEMENT PER CUBIC YARD & NO MORE THAN 6 GALLONS OF WATER PER SACK OF CEMENT. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO I.B.C. THE AMOUNT SHALL BE 4% + 1 % BY VOLUME. f'c = 3,000 psi. 14. REINFORCING STEEL SHALL CONFORM TO ASTM A615, (INCLUDING SUPPLEMENT S1) GRADE 60, fy = 60,000 psi. EXCEPTION: COLUMN TIES, BEAM STIRRUPS, BARS TO BE FIELD BENT, BARS TO BE WELDED & ANY OTHER BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy = 40,000 psi REINFORCING COMPLYING WITH ASTM A706 (S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D1.4 ARE SUBMITTED. NO REINFORCING SHALL BE WET -SET UNLESS SPECIFICALLY SO DETAILED. WELDED WIRE MESH SHALL CONFORM TO ASTM A-185. 15. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS & BENDS) IN ACCORDANCE WITH ACI 318-19. LAP ALL CONTINUOUS REINFORCEMENT 58 BAR DIAMETERS (2'-6" min.). PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS 30 BAR DIAMETERS (2'-6" min.). LAP ADJACENT MATS OF WELDED WIRE FABRIC TWO SQUARES (min. OF 12") AT SIDES & ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 16. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS & OTHER UNFORMED SURFACES, EARTH FACE 3" FORMED SURFACES EXPOSED TO EARTH (i.e. WALLS BELOW GROUND) OR WEATHER #6 BARS OR LARGER 2" #5 BARS OR SMALLER 1 1 /2" COLUMN TIES OR SPIRAL & BEAM STIRRUPS 1 1 /2" SLABS & WALLS (INTERIOR FACE) 3/4" CAST -IN -PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS & DIMENSIONS OF DOOR & WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE MECHANICAL DRAWINGS FOR SIZE & LOCATION OF MISCELLANEOUS MECHANICAL OPENINGS THROUGH CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, & OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES, BOTH CAST -IN -PLACE & PRECAST. 17. NON -SHRINK GROUT (3,000psi MINIMUM STRENGTH) SHALL BE FURNISHED BY AN APPROVED MANUFACTURER & SHALL BE MIXED & PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURE'S PUBLISHED RECOMMENDATIONS. STEEL 18. STRUCTURAL STEEL DESIGN, FABRICATION, & ERECTION SHALL BE BASED ON ON THE A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, & ERECTION OF STRUCTURAL STEEL BUILDINGS", LATEST EDITION, PLUS ALL REFERENCES CODES. 19. STRUCTURAL WIDE FLANGE SHAPES TO CONFORM TO ASTM A992, Fy = 50 ks OTHER STRUCTURAL STEEL INCLUDING PLATES SHALL CONFORM TO ASTM A36, Fy = 36 ksi STEEL PIPE SHALL CONFORM TO ASTM A-53, TYPE E, OR S, GRADE B, Fy = 35 ksi STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, Fy = 46 ksm BOLTS SHALL CONFORM TO ASTM A307(CONNECTION BOLTS A325-N) EXPANSION SHALL BE "PARABOLT" or APPROVED EQUAL INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED RECOMMENDATION. EXPANSION BOLTS SHALL ALSO BE SIMPSON STRONG BOLT INSTALLED PER ICC-ESR REQUIREMENTS OR EQUAL. 20. ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. & A.W.S. STANDARDS & SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PRE -QUALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70XX ELETRODES & PER ASTM A706. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. STEEL FABRICATION '7ENERAL: 41_1_ WELDING IS REQUIRED TO BE DONE BY A WABO CERTIFIED WELDER & HAVE SPECIAL INSPECTIONS BY WABO CERTIFIEC NSPECTION AGENCY, OR BE DONE IN A WABO CERTIFIED FABRICATION SHOP. SAVE EITHER THE SPECIAL INSPECTION REPORT OR WABO FABRICATION SHOP CERTIFICATION AVAILABLE ON SITE FOR THE 3UILDING INSPECTOR. 21. WELDING: 1) WELDING SHALL CONFIRM TO AWS D1.1 & VISUALLY CONFIRM TO AWS SECTION 6 & TABLE 6.1. FABRICATION/ERECTION INSPECTIONS BY THE CONTRACTOR PER AWS D1.1 SECTION 6, SHALL BE BY ASSOCIATE/CERTIFIED INSPECTORS (AWI/CWI) PER AWS QC1 OR AWS B5.1. SPECIAL INSPECTIONS (VERIFICATION INSPECTIONS SHALL BE BY A CERTIFIED WELDING INSPECTOR (WI) OR SENIOR WELDING INSPECTOR (SWI) PER AWS B5.1 2) WELDERS SHALL BE QUALIFIED FOR THE SPECIFIC PRE -QUALIFIED JOINTS REQUIRED BY THE DESIGN & CERTIFIED IN ACCORDANCE WITH WABO REQUIREMENTS. 3) WELDING SHALL BE DONE IN ACCORDANCE WITH APPROPRIATE WELD PROCEDURE SPECIFICATIONS (WPS's). WELDERS SHALL BE FAMILIAR WITH THE APPLICABLE WPS's. 4) WELDING SHALL BE DONE WITH AWS PRE -QUALIFIED WELDING PROCESSES UNLESS OTHERWISE APPROVED. 5) WELDER QUALIFICATIONS & WPS's SHALL BE MAINTAINED AT THE SITE OF THE WORK & SHALL BE READILY AVAILABLE FOR INSPECTION UPON REQUEST, BOTH IN THE SHOP & IN THE FIELD. 6) USE E70 OR E71T, 70ksi STRENGTH ELECTRODES APPROPRIATE FOR THE PROCESS SELECTED. 22. FABRICATION: 1) CONFORM TO AISC 303, SECTION 8 & AISC 360 SECTION M2 & M5. 2) STRUCTURAL WELDING & QUALIFICATIONS SHALL CONFORM TO THE AWS D1.1 23. VERIFICATION INSPECTION: 1) STRUCTURAL WELDING INSPECTIONS & QUALIFICATIONS SHALL CONFIRM TO THE AWS D1.1. SEE WELDING NOTES & SPECIAL INSPECTIONS FOR STRUCTURAL STEEL. 2) SPECIAL INSPECTOR SHALL REVIEW THE PROCEDURES FOR COMPLETENESS & ADEQUACY RELATIVE TO THE CODE & THE WORK. FURTHER SHOP SPECIAL INSPECTIONS MAY BE WAIVED IF THE FABRICATOR IS "AISC CERTIFIED" OR OTHERWISE "APPROVED" BY THE AUTHORITY HAVING JURISDICTION PER IBC SECTION 1704.2.2 SEE SPECIAL INSPECTIONS FOR STRUCTURAL STEEL. 24. ERECTION: 1) CONFIRM TO AISC 303, SECTION 7 "ERECTION", SECTION 8 "QUALITY ASSURANCE." & AISC 360, SECTION M4. 2) THE ERECTOR SHALL MAINTAIN DETAILED FABRICATION & ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT THE WORK IS PERFORMED IN ACCORDANCE WITH AISC 360 SECTION M, AISC 303, & THE CONTRACT DOCUMENTS. 3) STEEL WORK SHALL BE CARRIED UP TRUE & PLUMB WITHIN THE LIMITS DEFINED IN AISC 303, SECTION 7.13. 4) STRUCTURAL WELDING TO CONFORM TO THE AWS D1.1 & APPLICABLE WELDING NOTES ABOVE. 5) SPECIAL INSPECTOR SHALL INSPECT THE STEEL FRAMING TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE CONTRACT DOCUMENTS INCLUDING MEMBER SIZE, LOCATION, BRACING & THE APPLICATION OF PROPER JOINT DETAILS AT EACH CONNECTION. 25. BRACING & SAFETY PROTECTION: THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SAFETY PROTECTION REQUIRED BY AISC 360 SECTION M4.2 & AISC 303 SECTION 7010 & 7.11. 26. PROTECTIVE COATING REQUIREMENTS: 1) SHOP PAINTING: CONFORM TO AISC 360 SECTION M3 & AISC 303 SECTION 6.5 UNLESS A MULTI -COAT SYSTEM IS REQUIRED PER THE PROJECT SPECIFICATIONS. 2) INTERIOR STEEL: a. UNLESS NOTED OTHERWISE, DO NOT PAINT STEEL SURFACES TO BE, 1. WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD INSPECTION & NON-DESTRUCTIVE TESTING REQUIREMENTS, IF ANY, ARE SATISFIED. b. INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF SHOP PRIMER UNLESS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OR AS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. 27 29 30 01 32 WOOD FRAMING LUMBER SHALL BE KILN DRIED OR MC-15 (MC-192), & GRADED & MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 16 (172), LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2x MEMBERS) HEM -FIR #2 BEAMS & STRINGERS DOUGLAS FIR #1 POSTS & TIMBERS DOUGLAS FIR #1 STUDS, PLATES & MISC. LIGHT FRAMING DOUGLAS FIR or HIM -FIR STAND. GRADE TOP & BOTTOM PLATES @ BEARING & SHEAR WALLS DOUGLAS FIR #1 or CONST. GRADE BOLTED STUDS, LEDGERS & PLATES HEM -FIR #2 or CONST. GRADE 2 2x6 STUDS HEM -FIR #2 or HEM -FIR CONST. GRADE 2 GLUE -LAMINATED MEMBERS SHALL BEAR AN AITC IDENTIFICATION MARK & SHALL BE ACCOMPANIED BY AN AITC CERTIFICATION OF CONFORMANCE. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb= 2,400 psi, Fv = 240 psi. ALL CONT. & CANTILEVER BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2,400 psi, Fv = 240 psi. LAMINATED VENEER LUMBER SHALL BE FABRICATED IN CONFORMANCE WITH ICC-ES ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK. ALL BEAMS SHALL BE WESTERN SPECIES, GRADE 1.8E, Fb = 2,600 psi, Fv = 285 psi. LAMINATED STRAND LUMBER (TIMBERSTRAND LSL) SHALL BE FABRICATED IN CONFORMANCE WITH CODE EVALUATION ICC ES ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK. ALL BEAMS SHALL BE WESTERN SPECIES, GRADE 1.55E, Fb = 2,325 psi, Fv = 310 psi. PARALLEL STRAND LUMBER SHALL BE FABRICATED IN CONFORMANCE WITH ICC-ES ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK. ALL BEAMS SHALL BE DOUGLAS FIR, GRADE 2.OE, Fb = 2,900 psi, Fv = 290 psi [DEFERRED SUBMITTAL] PREFABRICATED OPEN WEB WOOD TRUSSES (or COMBINATION WOOD & METAL) SHALL BE DESIGNED BY THE MANUFACTURER FOR THE SPANS & CONDITIONS SHOWN ON THE PLANS & SHALL BE FURNISHED & INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ALL NECESSARY BRACING, BRIDGING, BLOCKING, PRE -NOTCHED PLATES ETC., SHALL BE DETAILED & FURNISHED BY THE MANUFACTURER. SUBMIT SHOP DRAWINGS & DESIGN CALCULATIONS (COMPLETE WITH STRESS DIAGRAMS) TO THE ARCHITECT & THE STRUCTURAL ENGINEER FOR REVIEW TWO WEEKS PRIOR TO FABRICATION. DESIGN SUBMITTALS SHALL BEAR THE STAMP OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. PERMANENT & TEMPORARY BRIDGING & BRACING SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS. 33. PLYWOOD SHEATHING SHALL BE GRADE C-D EXTERIOR GLUE or STRUCTURAL II, EXTERIOR GLUE ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE 1 RATING & PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX & NAILING REQUIREMENTS. STRUCTURAL WOOD SHEATHING PANELS SHALL HAVE APA GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. 34. ALL WOOD PLATES & BLOCKING IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN A.W.P.A. APPROVED PRESERVATIVE. PROVIDE 2-LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC., & CONCRETE OR MASONRY. 35. TIMBER CONNECTORS CALLED OUT BY LETTERS & NUMBERS SHALL BE BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL or GREATER LOAD CAPACITIES. PROVIDE NUMBER & SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTORS STRAPS CONNECT TWO MEMBERS, PLACE HALF OF THE NAILS or BOLTS IN EACH MEMBER. AS ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO TM A307. PROVIDE WASHERS UNDER THE HEADS & NUTS OF ALL BOLTS & LAG SCREWS BEARING ON WOOD UNLESS NOTED OTHERWISE. ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEASONED & DRIED & THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. ALL DOUBLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. ALL TRIPLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. TJI JOIST HANGERS PER MANUFACTURER TJI SHOP DRAWINGS (U.N.O.) 36. PROTECTION OF CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD ALL BOLTS, NAILS, JOIST HANGERS & ANY OTHER CONNECTORS SHALL BE HOT DIPPED GALVANIZED FASTENERS RECOMMENDED TO CONFORM WITH ASTM STANDARD A-153 & HOT DIPPED GALVANIZED CONNECTORS SHOULD CONFORM TO ASTM A165, CLASS G-183. STAINLESS STEEL FASTENERS & CONNECTORS SHOULD BE TYPE 304 OF 316 SIMPSON PRODUCT FINISHES CORRESPONDING TO THESE REQUIREMENTS ARE ZMAX 9158 (HOT DIPPED GALVANIZED) & SST3000 (STAINLESS STEEL). 37. ALL WOOD FRAMING DETAILS - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS. A. MINIMUM NAILING REQUIREMENTS: UNLESS OTHERWISE NOTED, MINIMUM NAILING SHALL BE IN ACCORDANCE WITH TABLE 2304.10.1 OF THE INTERNATIONAL BUILDING CODE. B. AT SAWN TIMBER JOIST AREAS: PROVIDE CROSS -BRIDGING @ 8'-0"o.c. max. SPACING & SOLID BLOCKING AT BEARING POINTS. PROVIDE DOUBLE JOISTS UNDER ALL PARTITIONS. PROVIDE DOUBLE JOISTS EACH SIDE OF OPENINGS UNLESS DETAILED OTHERWISE. C. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN HALF THE JOIST LENGTH & DOUBLE JOIST HEADERS & DOUBLE JOISTS EACH SIDE OF ALL OPENINGS IN FLOORS & ROOFS UNLESS DETAILED OTHERWISE. COORDINATE SIZE & LOCATION OF ALL OPENINGS WITH ARCHITECTURAL & MECHANICAL DRAWINGS. D. PROVIDE TWO 2x10 HEADERS OVER & DOUBLE STUDS EACH SIDE OF ALL OPENINGS IN STUD BEARING WALLS NOT DETAILED OTHERWISE. E. PROVIDE SOLID BLOCKING FOR WOOD COLUMNS & MULTIPLE STUD POSTS THROUGH FLOORS TO SUPPORTS BELOW. F. PROVIDE CONTINUOUS SOLID BLOCKING AT MID OF ALL STUDS OVER 10' IN HEIGHT. G. TOENAIL JOISTS TO SUPPORTS WITH 2-16d NAILS. ATTACH ALL BEAMS AT THE ROOF EXCEEDING 8'-0" IN LENGTH TO SUPPORTS WITH ST22 STRAP EACH END. H. ATTACH TIMBER JOISTS TO FLUSH HEADERS AND BEAMS WITH "U" SERIES METAL JOIST HANGERS TO SUIT THE JOIST SIZE. I. WALL FRAMING ALL STUD WALL SHOWN & NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ 16"o.c. AT INTERIOR WALLS & 2x6 STUDS @ 16" o.c. AT EXTERIOR WALLS. J. NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS, & OTHER CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY OR EQUIVALENT DEVICES BY OTHER MANUFACTURES MAY BE SUBSTITUTED. PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL LOAD CAPACITIES. K. INDIVIDUAL MEMBERS OF BUILT-UP POSTS & BEAMS SHALL EACH BE ATTACHED WITH 16d NAILS @ 6"o.c. STAGGERED. L. ALL WOOD STUDS WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS @ 6" o.c. STAGGERED UNLESS SHOWN OTHERWISE. M. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. N. PLYWOOD ROOF SHEATHING & FLOOR SHEATHING UNLESS OTHERWISE NOTED ON PLANS SHALL BE LAID UP WITH FACE GRAIN PERPENDICULAR TO SUPPORTS & NAILED WITH 8d NAILS @ 6" o.c. TO FRAMED PANEL EDGES & OVER STUD WALLS SHOWN ON PLANS & @ 12"o.c. (10"o.c. AT FLOORS TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED EDGE CLIPS @ 16"o.c. AT UNBLOCKED ROOF SHEATHING EDGES. PROVIDE SOLD BLOCKING AT LINES OF SUPPORT AT FLOORS. TOENAIL BLOCKING TO SUPPORTS WITH 16d NAILS @ 12"o.c. UNLESS OTHERWISE NOTED IN THE SHEAR WALL SCHEDULE. 0. PLYWOOD WALL SHEATHING SHALL HAVE SOLID BLOCKING AT ALL EDGES. P. ALL WOOD STUD WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 6"o.c. STAGGERED or BOLTED TO CONCRETE WITH 5/8" DIA. ANCHOR BOLTS @ 4'-0"o.c. UNLESS SHOWN OTHERWISE. Q. PLYWOOD NAILING: (USE UNLESS GREATER NAILING IS DETAILED OR SPECIFIED) 8d @ 6"o.c. AT SHEET EDGES 8d @ 12"o.c. AT INTERMEDIATE BEARING POINTS R. 1. PROVIDE ABU POST BASE @ ISOLATED POSTS TO CONCRETE CONNECTION 2. PROVIDE (2)A35 CLIPS @ TOP & BOTTOM OF ALL POST TO OTHER FRAMING MEMBERS 3. PROVIDE AC or LCE POST CAP @ ISOLATED POSTS TO BEAM CONNECTIONS 4. PROVIDE MIN. (2)A35 CLIPS @ POST TO BEAM CONNECTION (U.N.O.) 5. PROVIDE (2)CS16 x 30" AT ALL CUT DOUBLE TOP PLATES, TYPICAL. S. PROVIDE (2)CS16 x 36" AT ALL CUT DOUBLE TOP PLATE, TYP. T. ANCHORAGE: EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON STRONG -TIE COMPANY. INSTALL II STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-2508. MINIMUM BASE MATERIAL TEMPERATURE IS 507. RODS SHALL ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL INSPECTION OF INSTALLATION IS REQUIRED TO VERIFY ANCHORLC EMBEDDED BAR TYPE & DIMENSIONS, LOCATION, ADHESIVE IDENTIFICATION & EXPIRATION, HOLE DIMENSIONS, HOLE CLEAN117 PROCEDURE, ANCHOR EMBEDMENT & ADHERENCE TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR HORIZONTAL & OVERHEAD INSTALLATIONS. EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "AT-XP" AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH IAMPO REPORT NO. ER-0281. MINIMUM BASE MATERIAL TEMPERATURE IS 147. RODS SHALL BE ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL INSPECTION OF INSTALLATION IS REQUIRED TO VERIFY ANCHOR OR EMBEDDED BAR TYPE & DIMENSIONS, LOCATIONS, ADHESIVE IDENTIFICATIONS & EXPIRATION, HOLE DIMENSIONS, HOLE CLEANING PROCEDURE, ANCHOR EMBEDMENT, & ADHERENCE TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR HORIZONTAL & OVERHEAD INSTALLATIONS. REVISION Jun 12 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT ■ U(y) o o rn z_CY) � Q N O �^ VJ -0 c 0 L J CU L0 X W Z IL z L 4- o N � o M W rI� O N m v N °° Z`� a� LO W E w _ co L.L r ` N E O U r P cn a� r- .M c w m Project Project No. Drawn By Date 08-28-2023 Sheet S3 12%18" PLOT = 1 /2 SCALE