Loading...
APPROVED BLD2023-0401+Structural_Plan+3.31.2023_5.19.35_PM+3457666GENERAL STRUCTURAL NOTES ISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON PLANS (OR IN DETAILS) WOOD ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS H V (THE FOLLOWING APPLY UNLESS SHOWN OTHERWISE ON THE PLANS) ARE MINIMUM AND FOR GUIDANCE ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. Harriott Valentine Engineers Inc. MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD WORKING WITH THE 20. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15, AND GRADED AND MARKED IN CON- ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS 1932 First Avenue, Suite 720 CRITERIA TESTING LAB AND SOILS ENGINEER. BACKFILL BEHIND ALL RETAINING WALLS WITH FORMANCE WITH WCLIB STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17, UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UN- Seattle, Washington98101-2447 FREE DRAINING GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE AS NOTED LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: LESS NOTED OTHERWISE, ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEA- tel2066244760fax 2064476971 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE IN THE SOILS REPORT. SONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. HANGERS `^ww.harriottvalentine.com DRAWINGS, SPECIFICATIONS, THE INTERNATIONAL BUILDING CODE (2018 EDITION), JOISTS: (2X MEMBERS) HEM -FIR NO. 2 IN DIRECT CONTACT WITH PRESERVATIVE -TREATED WOOD SHALL BE EITHER STAINLESS & LOCAL BUILDING CODE MODIFICATIONS TO THE INTERNATIONAL BUILDING CODE. ALLOWABLE SOIL PRESSURE. . . . . . . . . 2500 PSF MINIMUM BASE VALUE, FB = 850 PSI STEEL (SST300), POST HOT -DIPPED GALVANIZED(HDG) OR GALVANIZED WITH A MINI - (3X & 4X MEMBERS) DOUGLAS FIR NO. 1 MUM OF 1.85OZ ZINC PER SQUARE INCH (ZMAX). UNLESS NOTED OTHERWISE, ALL 2. DESIGN LOADING CRITERIA: SOILS REPORT REFERENCE: GEOTECH CONSULTANTS N0. JN23011 MINIMUM BASE VALUE, FB = 1000 PSI LUMBER JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "LUS" SERIES JOIST : ........ _ The folio ................... " " " ing documentation shall be available CONCRETE HANGERS, AND ALL TJI JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "ITT" site forth building inspector - FLOOR LIVE LOAD (RESIDENTIAL) . . . . . . . . . . . . . . . . . . .40 PSF STRUCTURAL LIGHT FRAMING: DOUGLAS FIR NO. 2 OR IUT" SERIES JOIST HANGERS. FLOOR FLOOR LIVE LOAD (BALCONIES AND DECKS) . . . . . . . . . . . . . . .60 PSF 10. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORD- (INCL. 3X AND 4X POSTS) MINIMUM BASE VALUE, FB = 900 PSI - _ �X COE APPROVED ARCHITECTURAL PLAN SET ROOF SNOW LOAD (Pf)PSF 26. NAILS NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING . . . . . . . . . . . . . . . . . . . . . . . .25 ANCE WITH IBC SECTION 1905 AND ACI 301. CONCRETE SHALL ATTAIN A 28-DAY BEAMS AND STRINGERS: DOUGLAS FIR NO. 1 - X❑ COE AF PROVED STRUCTURAL PLAN SET WIND: STRENGTH OF F' C = 2, 500 PSI. THE CONCRETE M I X SHALL CONTAIN A MAXIMUM OF (INCL. 6X AND LARGER) MINIMUM BASE VALUE, FB - 1350 PSI SPECIFICATIONS: COE REVIEWED CALCULATION PACKET BASIC WIND SPEED (3-SECOND GUST) 100 MPH 330 POUNDS OF CEMENT PER CUBIC YARD AND SHALL HAVE A HIGH (30 PERCENT OR ENERGY SIZE LENGTH DIAMETER CREDIT WORKSHEET WIND IMPORTANCE FACTOR (Iw). 1.0 MORE) SCM (SUPPLEMENTARY CEMENTITIOUS MATERIALS, SUCH AS FLYASH OR SLAG) POSTS AND TIMBERS: DOUGLAS FIR NO. 1 SITE PN 6D 2" 0.113" '� WIND EXPOSURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . g CONTENT. CEMENT SHALL BE A BLENDED HYDRAULIC CEMENT CONFORMING TO (6X6 AND LARGER ) MINIMUM BASE VALUE, FC - 1000 PSI : ❑ CIVIL PLAN 8D 2-1/2 0. 131 TOPOGRAPHICAL FACTOR (Kzt). 1.04 ASTM C595. STUDS, PLATES & MISC. FRAMING: DOUGLAS FIR OR HEM STANDARD GRADE 10D 3" 0.148;; ! ❑ TO THE -FIR 12D 3-1/4 0.148 A CONCRETE PERFORMANCE MIX SHALL BE SUBMITTED ARCHITECT, STRUCTURAL EARTHQUAKE: LAT. 47.788 ENGINEER AND THE BUILDING DEPARTMENT FOR APPROVAL TWO WEEKS PRIOR TO 2X6 STUDS AND PLATES: HEM -FIR N0.3 STUD GRADE / 16D 3-1/2" 16" 0. 162" , , , , , , , , CITY o: ;D; o;D; BUILDING DEPARTMENT : 02= . . . /LONG. /-122.377 PLACING ANY CONCRETE. THE CONCRETE PERFORMANCE MIX SHALL INCLUDE THE SEISMIC IMPORTANCE FACTOR (Ie) . . . . . . . . . . . . . . . . . . . 1.0 AMOUNTS OF CEMENT, SUPPLEMENTARY CEMENTITIOUS MATERAAS, FINE AND COARSE 21. ENGINEERED LUMBER MEMBERS SHALL BE MANUFACTURED UNDER A PROCESS BY THE IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT SEISMIC USE GROUP. I AGGREGATE, WATER AND ADMIXTURES AS WELL AS THE WATER CEMENT RATIO, SLUMP, NATIONAL RESEARCH BOARD. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) APPROVED PLANS MUST BE MAPPED SPECTRAL RESPONSE (Ss/Si) . . . . . . . . . . . . . . .1.28g/0.45g CONCRETE YIELD & SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ARTICLE THE NAME AND PLANT NUMBER OF THE MANUFACTURER, THE GRADE, THE NATIONAL FOR REVIEW AND APPROVAL. NAILS SHALL BE DRIVEN FLUSH TO FACE OF SPECTRAL RESPONSE COEF. (SDS/SD1) . . . . . . . . . . . . . .1.02g/0.54g 4.2.3 OF ACI 301. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD RESEARCH BOARD NUMBER, AND THE QUALITY CONTROL AGENCY. ALL LUMBER SHALL SHEATHING WITH NO COUNTERSINKING PERMITTED. ON JOB SITE SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . D INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT BE MANUFACTURED IN ACCORDANCE WITH THE APPROPRIATE NER REPORT AND GLUED ANALYSIS PROCEDURE . . . . . . . . . . . . . . .EQUIVALENT LATERAL FORCE DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL RESPONSIBILITY FOR WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL 27• WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN: ALL WORK SUBJECT SPECIFIED PERFORMANCE. GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. TO FIELD SEISMIC FORCE RESISTING SYSTEM: . . . . . . . . . . .PLYWOOD SHEAR WALLS A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED INSPECTION F O R DESIGN BASE SHEAR . . . . . . . 12.5k ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR- PSL FB = 2900 PSI E = 2000 KSI FV = 290 PSI NER-292 TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM CODE COMPLIANCE SEISMIC RESPONSE COEFICIENT (Cs) . . . . . . . . . . . . . . . . . .0.158 ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, AND LSL FB = 2250 PSI E = 1500 KSI FV = 285 PSI NER-481 NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF RESPONSE MODIFICATION FACTOR (R) 6. 5 C618. TOTAL AIR CONTENT SHALL BE I N ACCORDANCE WITH TABLE 19. 3. 2. 1 OF THE LVL FB - 2600 PSI E - 1800 KSI FV - 285 PSI NER-126 THE INTERNATIONAL BUILDING CODE. UNLESS NOTED OTHERWISE, ALL NAILS ,.,.,....................................., ACI 318. SHALL BE COMMON. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS REVIEWED SEISMIC FORCE RESISTING SYSTEM: . . . . . . STEEL ORDINARY MOMENT FRAMES DESIGN SHOWN ON PLANS IS BASED ON LUMBER MANUFACTURED BY THE WEYERHAUSER WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER BY DESIGN BASE SHEAR . . . . . . 28.2k 11. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), CORPORATION. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. = CITY OF E D M O N DS SEISMIC RESPONSE COEFICIENT (Cs) . . . . . . . . . . . . . . . . . .0.293 GRADE 60, FY = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST BUILDING DEPARTMENT RESPONSE MODIFICATION FACTOR (R) . . . . . . . . . . . . . . . . . . 3.5 HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED B. WALL FRAMING: ALL STUD WALLS SHOWN AND NOT OTHERWISE NOTED SHALL BE y ...................... 12. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORD- THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST 2X4 STUDS @ 16" O.C. AT INTERIOR WALLS AND 2X6 @ 16" O.C. AT EXTERIOR REFERENCE: USGS NATIONAL SEISMIC HAZARD MAPPING PROJECT, 2008 DATA ANCE WITH ACI 318. LAP ALL CONTINUOUS REINFORCEMENT 40 BAR DIAMETERS HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS WALLS. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTER- PROVIDED. AND AT EACH SIDE OF ALL OPENINGS. TWO 2X8 HEADERS SHALL BE PROVIDED HAR�j� 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL SECTIONS. LAP CORNER BARS 40 BAR DIAMETERS OR 2'-0" MINIMUM. LAP OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COL- F wns� DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. ALL PROPOSED HOLE SIZES AND LOCATIONS SHALL BE SUBMITTED TO THE STRUCTURAL UMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. WALLS SHALL? r;;, o AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY ENGINEER FOR APPROVAL TWO WORKING DAYS PRIOR TO DRILLING HOLES. HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE DISCREPANCIES PRIOR TO CONSTRUCTION. 13. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: TO EACH STUD WITH TWO 16D NAILS AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH TWO 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D „ ��,J!9 A. FOOTINGS AND OTHER UNFORMED SURFACES, EARTH FACE 4. CONTRACTOR SHALL DETERMINE THE LOCATION OF ALL ADJACENT UNDERGROUND . . .3" B. ALL OTHER SURFACES 1 1/2" 22. PREFABRICATED PLYWOOD WEB JOIST DESIGN SHOWN ON PLANS IS BASED ON JOISTS AT 12 O.C. AND LAP MINIMUM 4 -0 AT JOINTS AND PROVIDE SIX 16D NAILS �oNni.ti�'�' 3/23/23 UTILITIES PRIOR TO COMMENCING EXCAVATION. THE CONTRACTOR SHALL BRING ALL . MANUFACTURED BY THE WEYERHAUSER CORPORATION AND SHALL BE FURNISHED AND AT 4" O.C. EACH SIDE OF JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER CONFLICTS AND DISCREPANICES TO THE ATTENTION OF THE ARCHITECT AND 14. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16D NAILS AT 12" O.C. Project Contact STRUCTURAL ENGINEER. , SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURER S ALL NECESSARY BRIDGING, BLOCKING, BLOCKING PANELS, STIFFENERS, ETC., SHALL STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH Henry Nuckles PUBLISHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO BE DETAILED AND FURNISHED BY THE MANUFACTURER. SUBMIT SHOP DRAWINGS TO �� �� 7 M I N I MUM EMBEDMENT) @ 4 -0 0. C. UNLESS I ND I CATED OTHERWISE. I ND I V I - tel 206 413 6664 hnuckles@harriottvalentine.com 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND THE MATERIAL ON WHICH IT IS PLACED (3000 PSI MINIMUM). THE ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION. DUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ALTERNATE PLYWOOD WEB JOIST MANUFACTURERS MAY BE USED SUBJECT TO REVIEW 16D @ 12" O.C. STAGGERED. REFER TO THE PLANS AND SHEAR WALL SCHEDULE ACCORDANCE WITH THE PLANS. ANCHORAGE AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER. ALTERNATE JOIST FOR REQUIRED SHEATHING AND NAILING. WHEN NOT OTHERWISE NOTED, PROVIDE Project Architect HANGERS AND OTHER HARDWARE MAY BE SUBSTITUTED FOR ITEMS SHOWN PROVIDED GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND Patricia Brennan Architects 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL JOIST 4515C Bagley Ave N Seattle, WA98103 METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 15. EPDXY -GROUTED ITEMS SPECIFIED ON THE DRAWINGS SHALL BE GROUTED WITH HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH PLYWOOD WEB BOTTOM PLATES AND BLOCKING WITH NAILS AT 7" O.C. USE 5D COOLER NAILS THE STRUCTURAL ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL "SET-3G" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON COMPANY JOIST PROVIDED. FOR 1/2" GWB AND 6D COOLER NAILS FOR 5/8" GWB. WHEN NOT OTHERWISE Project AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE AND INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2508. NOTED, PROVIDE 1/2" (NOM.) APA RATED SHEATHING (SPAN RATING 24/0) ON Shen Federman SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CON- "TITEN ALL HOLES SHALL CONFORM TO THE MANUFACTURERS SPECIFICATIONS. IF THREE OR EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES) , 23310 Humber Lane TRACTOR. THE STRUCTURAL ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, 16. TITEN HD ANCHORS SPECIFIED ON THE DRAWINGS SHALL CONSIST OF HD" FEWER HOLES ARE PROPOSED FOR A SINGLE JOIST, HOLES SHALL CONFORM TO THE TOP AND BOTTOM PLATES WITH 8D @ 6" O.C. AND TO ALL INTERMEDIATE STUDS Edmonds, WA98020 CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES OF THE OWNER, CON- HEAVY DUTY SCREW ANCHORS AS MANUFACTURED BY THE SIMPSON COMPANY AND WEYERHAUSER ILEVEL TJI ALLOWABLE HOLE CHART. IF MORE THEN THREE HOLES ARE AND BLOCKING WITH 8D @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. INSTALLED IN STRICT ACCORDANCE WITH ICC ESR 2713. PROPOSED FOR ONE SINGLE JOIST, ALL HOLE SIZES AND LOCATIONS SHALL BE SUB- AND ENDS. Issue Date Issue Description M I TTED TO THE STRUCTURAL ENGINEER FOR APPROVAL TWO WORKING DAYS PRIOR TO 7. SPECIAL INSPECTION OF THE FOLLOWING TYPES OF CONSTRUCTION SHALL BE STEEL DRILLING HOLES. C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS AROUND ALL OPENINGS IN 03/23/2023 Permit Submittal PROVIDED IN ACCORDANCE WITH SECTIONS 109 AND 1704 OF THE INTERNATIONAL FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL BUILDING CODE AND THE PROJECT SPECIFICATIONS BY A QUALIFIED TESTING 17. STRUCTURAL STEEL DESIGN, FABRICATION, AND ERECTION SHALL BE BASED ON 23. PLYWOOD SHEATHING SHALL BE GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, BEARING POINTS. TOENAIL JOISTS TO SUPPORTS WITH TWO 16D NAILS. ATTACH AGENCY DESIGNATED BY THE ARCHITECT, AND RETAINED BY THE BUILDING OWNER. THE LATEST EDITIONS OF THE RISC SPECIFICATIONS AND CODES: EXTERIOR GLUE IN CONFORMANCE WITH APR STANDARDS. ORIENTED STRAND TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH METAL JOIST HANGERS IN THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND SPAN RATING MAY BE ACCORDANCE WITH TIMBER CONNECTOR NOTE. NAIL ALL MULTI -JOIST BEAMS TO - FURNISHED WITH COPIES OF ALL INSPECTION AND TEST RESULTS. A. SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS (RISC 360) USED IN LIEU OF PLYWOOD. GETHER WITH 16D @ 12" O.C. STAGGERED. UNLESS OTHERWISE NOTED ON THE PLANS, ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH STRENGTH AXIS A. STRUCTURAL STEEL FABRICATION AND ERECTION (INCLUDING FIELD WELDING B. CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES (A I SC 303) A. ROOF SHEATHING SHALL BE 1 /2" (NOM.) WITH SPAN RATING 24/0. PERPENDICULAR TO SUPPORTS AND NAILED WITH 8D NAILS @ 6" 0. C. TO FRAMED Building Department Approval AND HIGH -STRENGTH FIELD BOLTING) B. FLOOR SHEATHING SHALL BE 3/4" (NOM.) WITH SPAN RATING 40/20. PANEL EDGES AND OVER STUD WALLS AS SHOWN ON PLANS AND @ 12" O.C. TO B. EPDXY GROUTED INSTALLATIONS C. SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR AONLY C. WALL SHEATHING SHALL BE 1/2" (NOM.) WITH SPAN RATING 24/0. INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BOLTS. BOLTS IN SHEAR OR BEARING TYPE CONNECTIONS NEED ONLY BE BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR 8. SHOP DRAWINGS FOR THE FOLLOWING ITEMS SHALL BE SUBMITTED TO THE TIGHTENED TO THE SNUG TIGHT CONDITION PER SECTION 8(C). REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING. SHEATHING EDGES SHALL HAVE APPROVED TONGUE -AND -GROOVE JOINTS OR SHALL ARCHITECT AND STRUCTURAL ENGINEER FOR REVIEW PRIOR TO FABRICATION OF BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL RECEIVED THESE ITEMS. 18. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING MINIMUM STANDARDS. 24. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE- EDGES AND ENDS OF ALL ROOF AND FLOOR SHEATHING. TOENAIL BLOCKING TO Apr 132023 PLATES, ANGLES, AND CHANNELS SHALL CONFORM TO ASTM A36, FY = 36 KSI. TREATED WITH AN APPROVED PRESERVATIVE OR (2) LAYERS OF ASPHALT IMPREGNATED SUPPORTS WITH 16D @ 12" O.C. UNLESS OTHERWISE NOTED. AT BLOCKED FLOOR DEEL°MENTER�`ES DEPARTMENT A. STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, FY = 50 KSI. STEEL BUILDING PAPER SHALL BE PROVIDED BETWEEN UNTREATED WOOD AND CONCRETE OR AND ROOF DIAPHRAGMS PROVIDE FLAT 2X BLOCKING AT ALL UNFRAMED PLYWOOD PIPE SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B, FY = 35 KSI. MASONRY. ALL WOOD EXPOSED TO WEATHER WITHOUT THE ADEQUATE PROTECTION OF PANEL EDGES AND NAIL WITH EDGE NAILING SPECIFIED. APPROVED SETS OF ALL SHOP DRAWINGS SHALL ALSO BE SUBMITTED TO THE SQUARE OR RECTANGULAR STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, A ROOF OR EAVE SHALL BE AN APPROVED WOOD OF NATURAL RESISTANCE TO DECAY BUILDING DEPARTMENT. GRADE B, FY = 46 KSI. ANCHOR BOLTS AND CONNECTION BOLTS SHALL CONFORM OR PRESSURE TREATED. SUCH MEMBERS INCLUDE HORIZONTAL MEMBERS SUCH AS Drawing Title TO ASTM A307. THREADED ROD AND STUDS SHALL CONFORM TO ASTM A36. GIRDERS, JOISTS, AND DECKING; OR VERTICAL MEMBERS SUCH AS POSTS, POLES, GENERAL STRUCTURAL GEOTECHN I CAL AND COLUMNS. NOTES 19. ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS AND SHALL 9. FOUNDATION NOTES: SUBGRADE PREPARATION INCLUDING DRAINAGE, EXCAVATION, BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY 25. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" COMPACTION, AND FILLING REQUIREMENTS, SHALL CONFORM STRICTLY WITH REC- PREQUALIFIED WELDS (AS DEFINED BY AWS) SHALL BE USED. BY SIMPSON COMPANY, AS SPECIFIED IN THEIR MOST RECENT CATALOG. EQUIVALENT B L D 2 0 2 3 - 04 0 1 Drawing Number OMMENDATIONS GIVEN IN THE SOILS REPORT OR AS DIRECTED BY THE SOILS ENGI- DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC NEER. FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COM- APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN S100 PACTED STRUCTURAL FILL OR BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FIN- w z w U) w z Q w 0 U_ z w _ co TYPICAL SLAB 4" THICK SLAB REINF. W/ W2.9xW2.9 6x6 W.W.M. CTR'D. RIGID INSUL. PER ARCH'L. —x x x x x x- CONTROL —x x x% rx x x— JOINT --o�000°o° 0 �o°O000 0 0 8°°oa 0°Oc�8° �°°� °a °°0°8 00 2nd POUR I. 1st POUR CON STR. —x x x x x x— JOINT °o 0 00.000 0—O-U00000077 8 °o 0 oa° °°oog o oo� o °°o�g o DOUBLE CURTAIN SI N GLE CURTAIN --- 6 MIL VAPOR BARRIER 4" FREE —DRAINING GRANULAR FILL CONTROL JOINT FORMER "ZIP STRIP" 11/2" DEEP (JOINT MAY BE SAW —CUT AT CONTRACTOR'S OPTION) CUT ALT. WIRES AT JOINT PLASTIC JOINT KEY "MEADOW BURKE" STOP REINF. 1" CLEAR OF JOINT EACH SIDE LEGEND SPAN �e > EXTENT X SECTION DETAIL X. (FB) FLUSH BEAM (PT) PRESSURE -TREATED COLUMN ABOVE 0 COLUMN BELOW NEW STRUCTURAL WALL HANGER SCHEDULE MEMBER (FLAT ONLY) HANGER 117/8" TJI 110 IUS1.81/11.88 117/8" TJI 560 IUS3.56/11.& 2x8 LUS28 (2)2x8 LUS28-2 EXISTING STRUCTURAL WALL NEW CONCRETE WALL EXISTING CONCRETE WALL ► MOMENT CONNECTION SLAB —ON —GRADE (INSULATED) y ALL -THREAD HOLDOWN AT „ ��� END OF SHEARWALL ABOVE 3/4 = 1 —0 2 STRAP HOLDOWN AT END OF SHEARWALL ABOVE CONCRETE WALL (1) #5 OR #4 DIAGONAL IN WALL TYP. FOOTING REINFORCING TYPICAL STEPPED FOOTING 3/4" = 1'-0" CORNER BARS TO MATCH EXT. HORIZ. REINF. AS SHOWN TYPICAL CORNER BARS: 24 24r CORNER BARS TO MATCH HORIZONTAL REINFORCING (ALTERNATE HOOKS) TIPICAL CORNER BARS: 24 24r TYPICAL CORNER BARS AT CONCRETE WALLS 3/4" = 1'-0" 4 FOUNDATION PLAN NOTES 1. WHERE NEW CONCRETE WALLS OR FOOTING ABUT EX. CONCRETE, PROVIDE DOWELS #4 x 2'-0" TO MATCH HORIT REINFORCING, EMBED 5" IN EPDXY GROUT. 2. SEE 10/S4.0 FOR TYPICAL HOLDOWN REQUIREMENTS AT CONCRETE WALLS AND FOOTINGS. 3. SLAB -ON -GRADE SHALL BE PLACED AND CURED FOR A MINIMUM OF SEVEN DAYS BEFORE RETAINING WALLS ARE BACKFILLED. SEE RETAINING WALL DETAILS FOR SPECIFIC CONFIGURATION. 1 LOWER FLOOR S2.0 scale: 1/4" = V-0" WOOD -FRAMED STEPS PER ARCHITECTURAL rING 2.0 Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com 3123123 Project Contact Henry Nuckles tel 206 413 6664 hnuckles@harriottvalentine.com Project Architect Patricia Brennan Architects 4515C Bagley Ave N Seattle. WA 98103 Project Shen Federman 23310 Humber Lane Edmonds, WA 98020 Issue Date Issue Description 03/23/2023 Permit Submittal Building Department Approval RECEIVED Apr 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Drawing Title LOWER FLOOR FRAMING/ FOUNDATION PLAN Drawing Number SZO W z W 0 W W z Q ry W 0 W LL z W W PLATE NAILING PER SHEARWALL SCHEDULE LEGEND SHEARWALL PER PLAN FLOOR SHEATHING NAILING SPAN PER PLAN TRIM TONGUES AND/OR EXTENT GROOVES AT EDGE OF A35 PER SW SCHEDULE SHEATHING X X. SECTION DETAIL TJPs PER PLAN 10d BOX FACENAIL (BEAR 13/4" MIN.) (FB) FLUSH BEAM AT TOP AND BOTTOM TJI FLANGES (PT) PRESSURE -TREATED COLUMN ABOVE 11/4" LSL RIM 0 COLUMN BELOW (U.N.O. ON PLAN) NEW STRUCTURAL WALL 10d BOX EACH SIDE EXISTING STRUCTURAL WALL OF TJI TO PLATE - NEW CONCRETE WALL SHEARWALL PER PLAN DRIVE NAILS 11/2" MIN. FROM END OF TJI EXISTING CONCRETE WALL ► MOMENT CONNECTION ALL -THREAD HOLDOWN 3/4" SHEARWALL ABOVE END OFSHE STRAP HOLDOWN AT END OF SHEARWALL ABOVE SHEARWALL PER PLAN - TRIM TONGUES AND/OR GROOVES AT EDGE OF SHEATHING (3) 10d BOX EACH SIDE OF BLOCKING 11/4" LSL RIM (U.N.O. ON PLAN) SHEARWALL PER PLAN SHEARWALL PER PLAN � PLATE NAILING PER SHEARWALL SCHEDULE FLOOR SHEATHING NAILING PER PLAN A35 PER SW SCHEDULE TJPs PER PLAN BLOCK ONE BAY FULL - DEPTH @ 48 oc WITH LSL 11/4" RIMBOARD - FIT TIGHT TO TJI 10d BOX TOENAIL EACH SIDE OF LSL TO PLATE 3/4" = 1'-0" PLATE NAILING PER SHEARWALL SCHEDULE FLOOR SHEATHING NAILING PER PLAN (3) 10d BOX EACH �� � �/ / � TJI's PER PLAN SIDE OF BLOCKING / V 12d AT PANEL NAIL SPACING FOR LOWER SHEARWALL (STAGGER ALTERNATE SIDES) SHEARWALL PER PLAN BLOCK ONE BAY EACH SIDE FULL -DEPTH @ 48"oc WITH LSL 11/4" RIMBOARD - FIT TIGHT TO TJI's 3/4" = 1'-0" 4 HANGER SCHEDULE MEMBER (FLAT ONLY) HANGER FACE NAILING CAPACITY (Cd = 1.0) 2x8 LUS28 10d COMMON 1100 lb 117/8" TJI 110 IUS1.81/11.88 10d COMMON 1020 lb 117/8" TJI 560 IUS3.56/11.88 10d COMMON 1220 lb LVL 13/4x117/8 MIU1.81/11 16d COMMON 2880 lb FRAMING PLAN NOTES 1. SWINDICATES SHEARWALL TYPE PER SCHEDULE 8/S4.0. REFER TO DETAILS FOR TYPICAL SHEARWALL CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL WALL INFORMATION. 2. REFER TO GENERAL STRUCTURAL NOTES FOR FLOOR OR ROOF SHEATHING TYPE, THICKNESS, AND NAILING. 3. COLUMNS SHALL BE DOUBLE STUD MINIMUM, UNLESS NOTED OTHERWISE. SEE 11/S4.0. 4. AT ALL SHEARWALLS PROVIDE DOUBLE TOP PLATES AND SPLICE PER 12/S4.0. 5. CS__ INDICATES COILED STRAP TYPE PER SCHEDULE 6/S4.0. REFER TO DETAILS FOR TYPICAL STRAP ASSEMBLY. 6. POSTS 0, INCLUDING ENDS OF WALL OPENINGS, SHALL BE (2)2x6 UNLESS NOTED OTHERWISE. 7. GLAZING OVER STEEL TRELLIS SHALL CONSIST OF (2) LAYERS OF 3/8" THICK TEMPERED GLASS LAMINATED TOGETHER WITH 15 MIL POLYVINYL BUTYRAL INTERLAYER. 8. WITHIN DOTTED HATCH, BLOCK ALL UNSUPPORTED PANEL EDGES OF DIAPHRAGM WITH FLAT 2x4 AND NAIL ALL PANEL EDGES WITH 10d @ 3"0c. 1 /S3.3 12 1 /S3.3 2x8 @ 16"oc CV o 11 CD 3.37 1 C7x9.8 (FB) 4 , CS16 x 5-0" LONG - ATTACH TO SW TOP PLATE AND WF BEAM TOP NAILER S�6 AT CANTILEVERED HSS (TYP.) 10\ /6\ LM3.4.(FBA . m X ^ m X CSC ^ m L� X S C'��6 � m VC cNn 6' 11 Cn can SW1 rZ)L 074XII'. tis � �' S3.3 FRAME THIS WALL HSS 5x2x18 s, W/ 2x8 STUDS (TYP.) 8 FB i 3. LZI 2 ^� m771 S3 Cq HSS 5x2x18 co @ 86"oc �® c� (FB) N CV TC70.8 I 4 (FB) -- 3.3 - __ 2 2x8 ________(2)-LVL 13/4x91/4 1 S3.3 I ,yss SEE PLAN NOTE 7 2 v' S3.3 LA CS16 x 5'-0CD in LF 10 LONG. ATTACH I TO F.O. JOIST I AND F.O. WF BEAM ~ SW3� \s,6 UPPER FLOOR FRAMING PLAN (LOWER FLOOR WALLS scale: 1/4" = V-0" N (1) JOIST WITH- �RWALL BEYOND AT DASHED LINE) (2) LVL \SW4 4 3 SEE PLAN NOTE 7 C9X13_4 (FB 0o co ° I m X CX X ICE, 5� ^ m r— N� N� SW1 = --------- (2) LVL 13/4x117 1` -- c-3 O X CV X m o0 X a ^� _ ^ m Cn m UL 13/4x11 '/8 00 (FB) \ X co U J o > 7 O S3. o VL 13/4x11 7/8 (FB) c � GC���� �� PSL 31 /2x117 /s (FB) v 2 2X8 rT r I = ---- ..-.: - - - --- :. ---- :-...--- :--. -- ::-.- I ELEVATOR ..........."."." "."."........... 3 I OPENING .:.:.:.:.:.:.:.:.:..:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:. S2 I nPF BEARIN.G-WALL a ."... N 117/s». TJI ..1p" " " " " . ".� .. ..............."."."."..." .. . ........?oo C.......................... @.16.oc . I. f.. :.:.:.:.:.:.:..:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.:.. . / 2 ���, ®......................... . I S2. I.. ... .......................... ..................... SW4 .. ...�2).2x8. .. ..SW4.... ..".." " . 2 2x1.0........ SW4 ----------- ------------------------ I I I CS16 x 5'-0"117/8 TJI 110 @16"'c 9 CS16 x 5'-0" 1 LONG. ATTACH 3 LONG. ATTACH I TO JOIST TO T.O. JOISTS AND T.O. SW RIM LVL 13/4x11�js I I (FB) m U L� m ^o -- In N X I X \ 4 LVL 13 4x11 7 8 (FB) > I J _J 0 6 —I U-) 00 I _73 S3. N ~ OU ~ Oa It CV I A � ® CS16 x 5'-0" LONG CS16 x 5'-0" ATTACH TO SW RIM I1 LONG. ATTACH T.O. BEAM/JOIST TO T.O. JOISTS I IAND 1----,W1OX45 FB - do �1---- - 1 3.,- WELD HOLDOWN ALL- I THREAD TO TOP FLANGE OF WF BEAM (TYP.) I C SW1 (2)2x10 (2)2x10 SW1 4 4 3 SEE PLAN NOTE 8 FOR NAILING REQUIREMENTS WITHIN DOTTED HATCH c Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com 3123123 Project Contact Henry Nuckles tel 206 413 6664 hnuckles@harriottvalentine.com Project Architect Patricia Brennan Architects 4515C Bagley Ave N Seattle, WA 98103 Project Shen Federman 23310 Humber Lane Edmonds, WA 98020 Issue Date Issue Description 03/23/2023 Permit Submittal Building Department Approval RECEIVED Apr 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Drawing Title UPPER FLOOR FRAMING PLAN Drawing Number S2ml w 0 z W 0 w z 2i ry w 0 w LL z w 1: U) ■ A PANEL EDGE NAILING PER PLAN (8d @ Coc U.N.O.) BLOCK FULL -DEPTH (VENT PER ARCH'L.) TRIM RAFTER TAILS AS REQUIRED (SEE ARCH'L. FOR DIMS.) PANEL EDGE NAILING - PER SW SCHEDULE TO TOP PLATE (8d @ Coc U.N.O.) 8d @ Coc - TO BLOCKING RAFTER PER PL 1oIW.1IN! 8d @ Coc TO BEAM RAFTERS PER PLAN SHEARWALL PER PLAN :L1111: VI110».1II A35 PER SW SCHEDULE (@ 48"oc ELSEWHERE) SHEARWALL PER PLAN 3/4" = 1'-0" 2 17� 112A AT DI nr it 3/4" = 1'-0" BEAM PER PLAN ALIGNED OVER SHEARWALL (3) i6d AT BLOCK BLOCK ONE RAFTER BAY @ 48"oc EA. SIDE A35 PER SW SCHEDULE (@ 48"oc ELSEWHERE) 3/4" = 1'-0" 4 LEGEND X X. SPAN EXTENT SECTION DETAIL FB FLUSH BEAM PT) PRESSURE —TREATED COLUMN ABOVE COLUMN BELOW NEW STRUCTURAL WALL EXISTING STRUCTURAL WALL NEW CONCRETE WALL EXISTING CONCRETE WALL ► MOMENT CONNECTION ALL —THREAD HOLDOWN AT END OF SHEARWALL ABOVE STRAP HOLDOWN AT END OF SHEARWALL ABOVE FRAMING PLAN NOTES 1. SW__ INDICATES SHEARWALL TYPE PER SCHEDULE 8/S4.0. REFER TO DETAILS FOR TYPICAL SHEARWALL CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR ADDITIONAL WALL INFORMATION. 2. REFER TO GENERAL STRUCTURAL NOTES FOR FLOOR OR ROOF SHEATHING TYPE, THICKNESS, AND NAILING. 3. COLUMNS SHALL BE DOUBLE STUD MINIMUM, UNLESS NOTED OTHERWISE. SEE 11/S4.0. 4. AT ALL SHEARWALLS PROVIDE DOUBLE TOP PLATES AND SPLICE PER 12/S4.0. 5. CS__ INDICATES COILED STRAP TYPE PER SCHEDULE 6/S4.0. REFER TO DETAILS FOR TYPICAL STRAP ASSEMBLY. 6. POSTS p, INCLUDING ENDS OF WALL OPENINGS, SHALL BE (2)2x6 UNLESS NOTED OTHERWISE. HANGER SCHEDULE MEMBER (FLAT ONLY) HANGER FACE NAILING CAPACITY (Cd = 1.0) 2x12 LUS210 10d COMMON 1335 Ib 2x12 LUC2101 10d COMMON 1410 lb (2)2x12 LUS210-2 10d COMMON 1335 lb (2)2x12 HUC210-21 16d COMMON 2385 lb 1. CONCEALED FLANGE HANGERS ONLY NEED TO BE USED WHERE THE TYPICAL HANGERS CANNOT BE INSTALLED. ROOF FRAMING PLAN (UPPER FLOOR WALLS' scale: 1/4" = 1'-0° MEMBER HANGER FACE NAILING CAPACITY (SLOPED ONLY) (Cd = 1.15) 2x12 LRU21OZ 10d COMMON 1295 lb Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com Project Contact Henry Nuckles tel 206 413 6664 hnuckles@harriottvalentine.com Project Architect Patricia Brennan Architects 4515C Bagley Ave N Seattle. WA 98103 Project Shen Federman 23310 Humber Lane Edmonds, WA 98020 Issue Date Issue Description 03/23/2023 Permit Submittal Building Department Approval RECEIVED Apr 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Drawing Title ROOF FRAMING PLAN Drawing Number S12 W U z w w z ry W w LL z w _ CO " HV 1" 5" BASE E 1/2" BLOCK FULL -DEPTH Harriott Valentine Engineers Inc. OVER BEAM 3/16 ° ° (PLAN VIEW) 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 ° ° FACE OF SUPPORTING MEMBER tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com BEAM PER PLAN WITH JOISTS PER PLAN KERF E 3/8" AT WOOD BEAM AC EACH SIDE OF POST BEAR EACH JOIST 31/2" HSS COL. CONT. PER I SEE 1/S3.0 FOR TYP. 2" 1" WITH (2) 5/8"0 THRU-BOLTS PLAN FRAMING CALLOUTS °I =� WOOD BEAM PER PLAN X X BEAM PER PLAN W/ POST PER PLAN SEE 1/S3.0 FOR TYP. KERF SEAT CONN. II (4) 5/8"0 x 6" LONG1.0 N ' ABA SERIES POST BASE FRAMING CALLOUTS PER 4/S3.0 - BOTH SIDES OF BEAM I I I TITEN HD 1/2" NON -SHRINK GROUT DAP WOOD BEAM WHERE NOTED (ONLY) Ir SEAT E 1/2% BEAM WIDTH rn rn CD I %. ///�// /' //i��/ • TYP. 3�16 2'-6" SQUARE (4) #4 EA. WAY BOTTOM 3'-6" SQUARE • (5) #4 EA. WAY (7) #4 EA. WAY BOTTOM 4'-6" SQUARE BOTTOM TYPICAL KERF-SEAT CONNECTION 3/4" = 1'-0" 1 SHEARWALL PER PLAN 3/4" = 1'-0" 2 SHEARWALL PER PLAN 3/4" = 1'-0" 1-1/2)) = 1'-0" 4 SHEARWALL PER WALL PER PLAN OUTLINE WALL BEYOND ATTACH LEDGER TO CONC. PLAN THERMAL BREAK WALL W/ (2) 5/8" 0 x 6" THERMAL BREAK BLOCK ONE JOIST BAY THERMAL BREAK PER ARCH'L LONG TITEN HD @ 16"oc PER ARCH'L FULL -DEPTH @ 48"oc LEDGER PER 7/S3.0 PER ARCH'L 24" SLAB -ON -GRADE TJI's PER PLAN SLAB -ON -GRADE TJI's PER PLAN TJI's PER PLAN SLAB -ON -GRADE IF #4 x� @ 16"oc PER 2/S2.0 HANGERS PER SCHEDULE PER 2/S2.0 PER 2/S2.0 (1) #4 NOSING BAR x x x x x x x I I x x x x x x x I • • +I OPENING I+ x x x x x— tip' WHS Rojo SLAB -ON -GRADE °�°o°oo°°oo ° °�°°o°o°°�o °�°61G)% .18 �°o °6 °0o�°0°)8 °o 11 FOR ELEVATORo�°°o°o°�° CORE °°°�� 8 oo of �`�, , -�� ;; . o PAVING PER ARCH'L.---- + PER 2/S2.0 // /%// // // / //. //,// // // /F I Efl N F1// °�° // // \//. /� •' t 13/4" LSL LEDGER W 2//j//j/ LEDGER PER 6 S3.0 \�/%\�/%\' 29049 �ON'"'ti ' x x x x x x LAYERS OF ASPHALT /\�/�� W/ (1) 5/8"0 x 6" LONG REINFORCE THIS 3123123 ° 0�000 IMPREGNATED BUILDING y\\/\\/ // // TITEN HD @ 16 oc WALL PER 12/S3.0 \!/j\% Project Contact °/\'�\!/j\! \\\// PAPER (SEE 24/S1.0) '�\%j\! (TYP.) ° oo° ° , o0 0 °\\. / / // // / . Henry Nuckles tel 206 413 6664 hnuckles@harriottvalentine.com (2) #4 CONT. DRAINAGE PER / /�� / SEE 12/S3.0 FOR WALL /�� / SEE 12/S3.0 FOR WALL #4 CONT. @ 10"oc Project Architect 1._4" AND FOOTING CALLOUTS AND FOOTING CALLOUTS EA. WAY TOP & BrennanrNhitects PatARCHITECTURAL 451r5CBagley Ave 5' 6" 5-0" 6" 5" BOTTOM Seattle, WA 98103 Project 3/4" = 1'-0" 5 3/4" = 1'-0" 6 3/4" = 1'-0" 7 3/4" = 1'-0" 8 Shen Federman 23310 Humber Lane Edmonds, WA 98020 Issue Date Issue Description 03/23/2023 Permit Submittal SHEARWALL PER PLAN SHEARWALL PER PLAN A35 PER SW SCHEDULE LSL 11/4" RIMBOARD 26 P.T. PLATE WITH #4 @ 16"oc VERT. BLOCK ONE JOIST BAY 5/8" 0 ANCHOR BOLTS PER SHEARWALL PER PLAN (CENTERED) FULL -DEPTH @ 48oc #4 @ 16"oc VERT. SW SCHEDULE (@ 48"oc (ALT. HOOKS) ELSEWHERE) Building Department Approval 26 P.T. PLATE WITH 26 P.T. PLATE WITH #4 @ 10"oc HORIZ. 5/8" 0 ANCHOR BOLTS PER 5/8" 0 ANCHOR BOLTS PER [(2) AT TOP OF WALL] #4 @ 10"oc HORIZ. SW SCHEDULE (@ 48'oc SW SCHEDULE (@ 48'oc [(2) AT TOP OF WALL] JOISTS PER PLAN ELSEWHERE) SLAB -ON -GRADE ELSEWHERE) ch SLAB -ON -GRADE PER 2/S2.0 L PER 2/S2.0 (BOTH SIDES) I • RECEIVED / /\\/ x x � � Apr 132023 CITDYEOF Sx DEVELOPMENT SERVICES x x x x x x x x x x x x x I I O° ° °moo°o�o °Oo°0 OOP� ° St OO o°o° Y - Z ,\ to RETDMMEONNTD oo C4/ STRUCTURAL DETAILS O °O°o °° �° / / //\/ / / / / / ° 0°° ° °/�\�� /\��/��\/�\- ° °°° o ° ° \ \ \/\\ /\ \\\���\�\ ° °°° / ° ° e SEE 10/S3.0 FOR WALL DRAINAGE PER SEE 12/S3.0 FOR WALL AND FOOTING CALLOUTS ARCHITECTURAL 5" 6" 5' AND FOOTING CALLOUTS DRAINAGE PER ARCH'L. 5" 6" 5" (2) #4 CONT. Drawing Number „ 9 10 11 12 SIO 3/4 = 1 —0 3/4 = 1 —0 3/4 = 1 —0 3/4 = 1 —0 W z LU 0 LU z Lu 0 LU ILL. z LU HV Harriott Valentine Engineers Inc. II II 1932 First Avenue, Suite 720 SHEARWALL Seattle, Washington 98101-2447 PER PLAN tel 206 624 4760 fax 206 447 6971 PANEL EDGE NAILING PANEL EDGE NAILING Www.harriottvalentine.com PER PLAN (8d @ 6" U.N.O.) PER PLAN (8d @ 6" U.N.O.) II C II W ca l l_ W PANEL EDGE NAILING PER PLAN (8d @ 6"oc U.N.O.) PARAPET STUD WALL PER 11 /S3.2 A35 PER SW SCHEDULE PARAPET STUD WALL PER 11 /S3.2 A35 PER SW SCHEDULE DECK JOISTS PER PLAN TJI's PER PLAN 10d BOX FACENAIL TJI's PER PLAN (BEAR 13/4" MIN.) HANGERS PER SCHEDULE (3) 1Od BOX EACH AT TOP AND BOTTOM L SIDE OF BLOCKING TJI FLANGES BLOCK ONE BAY EACH STRAP PER PLAN - ra SIDE FULL -DEPTH WRAP UNDER BEAM 11/4" LSL RIM 11/4" LSL RIM — @ 48"oc WITH LSL 11/4" AND UP OPPOSITE (U.N.O. ON PLAN) (U.N.O. ON PLAN) RIMBOARD - FIT TIGHT FACE OF BEAM BLOCK ONE BAY FULL - TO TJI's 2x8 LEDGER W/ (2) TJI's PER PLAN DEPTH @ 48"oc WITH BEAM PER PLAN ROWS 1/4" 0 x 31/2" LONG LSL 11/4" RIMBOARD - 10d BOX EACH SIDE (SECTION) SDS SCREWS @ 10"oc BLOCK ONE BAY AND FIT TIGHT TO TJI OF TJI TO PLATE - NAIL PER 3/S2.1 SHEARWALL PER PLAN SHEARWALL PER PLAN DRIVE NAILS 11/2" MIN. 10d BOX TOENAIL EACH FROM END OF TJI WF BEAM PER PLAN W/ SIDE OF LSL TO PLATE BLOCKING PER 5/S3.2 TYPICAL STRAP AT BEAM (PARALLEL) 3/4" = 1'-0" 1 3/4" = 1'-0" 2 3/4" = 1'-0" 3 3/4" = 1'-0" 4 .I II SHEARWALL 11 PER PLAN II F] _I III II II STRAP PER PLAN- WRAP 2x BLOCK WITH PANEL Z ::III UNDER HEADER AND UP EDGE NAILING PER PLAN PANEL EDGE NAILING J II o INSIDE FACE OF HEADER (8d @ 6"oc U.N.O.) PER PLAN (8d @ 6"oc U.N.O.) — — — — — — X HAR D' IlE PANEL EDGE NAILING PER PLAN (8d @ 6"oc U.N.O.) 16d TO MATCH PANEL EDGE NAILING SPACING PANEL EDGE NAILING PER PLAN (8d @ 6"oc U.N.O.) 16d TO MATCH PANEL EDGE NAILING SPACING 2x (PT) BLOCK W/ (2) 5/8" 0 5" LONG TITEN tic, fp of W, S `w x o (STAINLESS ( ) ) RAMP STRINGERS (PT) �Fy.. •' t T _ _____________ 1� 7-1 L OUTLINE OF CONT. PER PLAN t L`' 29049 w HEADER - STRIP FOOTINGCi3 SON'"' 3/23/23 BEYOND Z \ // /\\�%\% Project Contact :. W PROVIDE STRAP AT EACH TJI's PER PLAN JOISTS PER PLAN TJI s PER PLAN JOISTS PER PLAN / / / / /\\/\\\�\/ \\% Henry Nuckles tel 206 413 6664 END OF HEADER TO MATCH HANGERS PER SCHEDULE HANGERS PER SCHEDULE //\//�/' CONT. REINF. FROM hnuckles@harriottvalentine.com (SECTION) I I II STRAP ABOVE -WRAP BEAM PER PLAN %j\\/ �,�,,\ FOOTING BEYOND PER II OVER HEADER AND DOWN BEAM PER PLAN (1) #4 CONT. 2'_7" 9/S3.1 Project Architect INSIDE FACE OF HEADER #4 @ 1 O"oc Patricia Brennan Architects 4515C Bagley Ave N Seattle, WA 98103 TYPICAL STRAPPED HEADER Project 3/4" = 1'-0" 5 3/4" = 1'-0" 6 3/4" = 1'-0" 7 3/4" = 1'-0" 8 Shen Federman 23310 Humber Lane Edmonds, WA 98020 Issue Date Issue Description REMOVE SIDING @ LEDGER SHEARWALL PER PLAN 03/23/2023 Permit Submittal BLOCK ONE JOIST BAY BLOCK FULL -DEPTH CONT. FLASHING W/ SEE 12/S3.0 FOR PLATE FULL -DEPTH @ 48"oc OVER BEAM DRIP EDGE (COORD. AND A35 CALLOUTS 2x6 P.T. PLATE WITH 2x6 P.T. PLATE WITH W/ ARCHITECTURAL) 5/8"0 ANCHOR BOLTS JOISTS PER PLAN 5/8"0 ANCHOR BOLTS JOISTS PER PLAN - BEAM PER PLAN @ 48"oc @ 48"oc BEAR EACH JOIST 3�/2" DECK JOISTS PER PLAN Building Department Approval HANGERS PER SCHEDULE JOISTS PER PLAN JOISTS PER PLAN II• • II• 8" 0 PLINTH, REINF. WITH POST PER PLAN 2x8 (PT) LEDGER W/ (2) II RECEIVED (4) #4 VERT. AND TIES o. ROWS 1/4" 0 x 31/2" LONG Apr 13 2023 3OPMENT #3 x @ oc ABA SERIES POST BASE SDS SCREWS @ 10"oc CI EPA TMONDS DEVEL SERVICES DEPARTMENT M • //\\// \/ • M \ � \/ Drawing Title STRUCTURAL DETAILS ° ° o cD o \\ \\\\\j\\j/\ //\//\//\�/\//\// �i iD ° //' i \//\\//\//\//\\//\// ° °°°° \/ \ ° � � SEE 12/S3.0 FOR WALL SEE 12/S3.0 FOR WALL (3) EACH WAY SEE 12/S3.0 FOR WALL AND FOOTING CALLOUTS AND FOOTING CALLOUTS #4 BOTTOM AND FOOTING CALLOUTS 2'-0" SQUARE Drawing Number „ Y—Opy 9 10 Y—Opy 1 12 S11 3/4 = 1 3/4 = 1 —0 3/4 = 1 3/4 = 1 —0 W z W 0 W z Q W 0 LL z W _ U) HV Harriott Valentine Engineers Inc. II 1932 First Avenue, Suite 720 STEEL BEAM PER PLAN Seattle, Washington 98101-2447 BLOCK WEB SOLID AND W18 BEAM PER PLAN +=1141-------------------------------- ° ° — tel 206 624 4760 fax 206 447 6971 ATTACH WITH 5/8"0 WOOD TOP NAILER o ° _ _ _ — _ _ www.harriottvalentine.com THRU—BOLTS @ 32"oc ATTACHED WITH 5/8" 0 THRU—BOLTS @ 32"oc SEE 7/S3.4 FOR II TJI JOISTS PER PLAN CP WELD REQ. (DIRECTION MAY VARY) (3) 10d BOX EACH AT TOP & BOT. 2$4" WITH HANGERS PER SIDE OF BLOCKING FLANGES SCHEDULE W10 BEAM PER PLAN 5/16 0 0 0 0 0 0 0 B.O. JOIST = B.O. STEEL FULL —DEPTH TJI BLOCKING WELD ACCESS L STEEL E 3/8" BOTH SIDES @ 48"oc WHERE JOISTS HOLES PER 11/S3.4 OF W18 WEB TO MATCH SEE 2/S3.2 FOR WELD WF BEAM PER PLAN ARE PARALLEL TO WF CP WEB W10 FLANGE WIDTH CALLOUTS ATTACHING BLOCKING AND NAILER TO WEB ROOF JOISTS PER PLAN WF BEAM PER PLAN ENDS OF WF BEAMS PER 1/S3.2 NOTE: PERPENDICULAR BOTH SIDE (WHERE OCCURS) BLOCKING AND NAILER TOGETHER WF BEAM W/ BOLTED HANGERS PER SCHEDULE PER 1/S3.2 CONNECTION OMITTED (4) 5/8" 0 THRU—BOLTS IN THIS DETAIL FOR AT BEAM GAGE CLARITY —SEE 4/S3.2 3/4" = 1'-0" 1 1-1/2" = 1'-0" 2 3/4" = 1'-0" 4 SEE 2/S2.2 FOR ROOF FRAMING CALLOUTS STEEL BEAM PER PLAN 2x BLOCKING EACH SIDE -------------- BLOCK WEB SOLID AND WITH PANEL EDGE NAILING , t B ATTACH WITH 5/8" 0 PER PLAN (8d @ 6"oc ------------------- THRU—BOLTS @ 32"oc AT OTHER LOCATIONS) - FLUSH BEAM PER PLAN FLUSH BEAM PER PLAN BLOCK UNDER RAFTER 16d TO MATCH PANEL ------------ _-------------- HANGER PER SCHEDULE ------------------------------------- FOR FULL BEARING ------------------------------------- � A HARk �oF HAi T.O. JOIST = T.O. STEEL EDGE NAILING SPACING 2x BLOCKING W/ PANEL A A � • EDGE NAILING PER PLAN --------J 'l------- RAFTERS PER PLAN W/ --------J ',------- BEAM (CONT.) PER PLAN --------J 'l------- RAFTERS PER PLAN HANGERS PER SCHEDULE ' .t 16d TO MATCH PANELJ EA. SIDE OF FLUSH BEAM BLOCK AND NAILING POST PER PLAN SHEARWALL PER PLAN L`' , EDGE NAILING SPACING PER 6/S3.2 PLATE NAILING PER �o �-�'�w V20 WF BEAM PER PLAN W/ WF BEAM PER PLAN W/ SHEARWALL SCHEDULE SON^'' 3123123 WEB BLOCKING AND WEB BLOCKING AND TOP NAILER PER 1/S3.2 TOP NAILER PER 1/S3.2 RAFTERS PER PLAN FLOOR SHEATHING NAILING Project Contact FLAT BLOCKING PER PLAN Henry Nuckles @ 482'oc WHERE JOISTS tel 206 413 6664 hnuckles@harriottvalentine.com ARE PARALLEL TO WF 2x RIM (U.N.O. ON PLAN) RAFTERS PER PLAN RAFTERS PER PLAN A35 PER SW SCHEDULE HANGERS PER SCHEDULE HANGERS PER SCHEDULE 10d BOX FACENAIL ATPat Project Architect SHEARWALL PER PLAN TOP & BOT. OF RAFTER 451r5C icia Bagley AveBrennanrNhitects Seattle, WA 98103 Project 3/4" = 1'-0" 5 3/4" = 1'-0" 6 3/4" = 1'-0" 7 3/4" = 1'-0" c� 8 Shen Federman 23310 Humber Lane Edmonds, WA 98020 Issue Date Issue Description PLATE NAILING PER 2x BLOCKING EACH SIDE PARAPET STUD 03/23/2023 Permit Submittal SHEARWALL SCHEDULE WITH PANEL EDGE NAILING WALL 2x6 @ 24"oc SHEARWALL PER PLAN FLOOR SHEATHING NAILING PARAPET STUD WALL PER 11/S3.2 PER PLAN (8d @ 6"oc U.N.O.) (2) 16d INTO 8d @ 6"oc TO BLOCK PARAPET STUD WALL PER 11/S3.2 PER PLAN 16d TO MATCH PANEL EA. RAFTER BLOCK FULL —DEPTH EDGE NAILING SPACING (VENT PER ARCH'L) A35 PER SW SCHEDULE Building Department Approval BLOCK WITH 11/4" LSL RIM BOARD TJI's PER PLAN (BEAR 13/4" MIN.) (3) 16d--------- (3) 16d AT BARGE RAFTER AT BLOCK BEAM PER RAFTERS PER PLAN RAFTERS PER PLAN RAFTERS RECEIVED PLAN RAFTERS PER PLAN HANGERS PER SCHEDULE WF BEAM PER PLAN W/ A35 PER SW SCHEDULE PER PLAN BLOCK ONE RAFTER Apr 132023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT HANGERS PER SCHEDULE WEB BLOCKING AND TOP (@ 482'oc ELSEWHERE) BAY @ 482'oc EA. SIDE 10d BOX EACH SIDE NAILER PER 1/S3.2 OF TJI TO PLATE SHEARWALL PER PLAN SHEARWALL PER PLAN SHEARWALL PER PLAN A35 PER SW SCHEDULE Drawing Title STRUCTURAL DETAILS ATTACH SW TOP PLATE (@ 48"oc ELSEWHERE) SHEARWALL PER PLAN TO WF BEAM W/ 5/8" 0 THRU—BOLTS @ 8"oc Drawing Number � 10 , 11 „ 12 S12 3/4„ = 1, —0„ 3/4„ = 1, —0„ 3/4„ = 1 —0„ 3/4 = 1, —0„ W U z W 0 W z W 0 W ILL z W _ 07 HV II B WF COLUMN PER PLAN Harriott Valentine Engineers Inc. II (ORIENTATION PER PLAN) 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 GRIND ALL WELDS FOR I ppI V tel 206 624 4760 fax 206 447 6971 SMOOTH FINISH (PLAN VIEW) 0110 of BEARING PLATE, WELDS, WWN.harriottvalentine.com II g AND BOLTS AS BELOW CHANNEL PER PLAN 3 SIDES (2) 5/8" 0 THRU-BOLTS 1" 3" 2" / WF BEAM PER PLAN II II 3/16 1 " CHANNEL PER PLAN I (4) 5/8" 0 THRU—BOLTS \ 1 = o o AT BEAM GAGE o o �� COLUMN WF BEAM PER PLAN 1 I AND BEAM 1 �-,-------T-� J 3/16 3/16 i CHANNEL PER PLAN WF BEAM PER PLAN W/ 0 O 1/2% B.O. CHANNEL = B.O. BLOCKING AND PER 5/S3.2 E BEAM WIDTH JOISTS BEYOND WITH (4) 5/8"0 THRU— 1 BOLTS @ BEAM GAGE 3/16 COPE B.O. CHANNEL (PLAN VIEW) HSS COL. BEYOND MITERED CHANNEL WELDED CONNECTION WF COLUMN BEARING ON WF BEAM 1-1 /2" = 1'-0" 1-1/2" = 1'-0" 2 3/4" = 1'-0" 3 3/4" = 1'-0" 4 SHEARWALL PER PLAN SEE 11 /S3.3 FOR STANCHION, SEE 11 /S3.3 FOR CALLOUTS FOR CENTER BEAM ENDS RAIL, INFILL, AND BASE E STRAP OVER PARAPET FOR 2 2 ON � OF HSS COLUMN TJI's PER PLAN CALLOUTS GUARDRAIL — OMITTED IN THIS / HSS PER PLAN — CAP HSS PER PLAN — CAP DETAIL FOR CLARITY WF BEAM PER PLAN EA. END W/ 3/16" E HSS PER PLAN (CANTILEVERED) EA. END W/ 3/16" E WELD AND SEAL ALL W/ BACKSPAN PER PLAN — ALIGN WELD AND SEAL ALL JOISTS PER PLAN AROUND (1) TJI ADJACENT TO HSS AND AROUND BLOCK TJI WEB SOLID EA. SIDE DECK ASSEMBLY PER ARCH'L Gov WA ��fo�, GLAZING PER PLAN ��_ GLAZING PER PLAN 1 ,w ... , Fi ,» I 2 I I I I I O o J J J II 1 L TOP E 1/2% BEAM L ay I I I WIDTH WITH 5/8"0 I I 3/23/23 I THRU-BOLTS 1 3 /16 ,,,,-- CHANNEL SISTER HSS TO ADJACENT TJI CHANNEL I AT BEAM GAGE PER PLAN 3/16 W/ (2) ROWS 5/8" 0 THRU—BOLTS PER PLAN 3/16 3/16 Project Contact I @ 16"oc — SEE BOT. LEFT FOR A35 PER SW SCHEDULE Henry Nuckles I SECTION THRU TJI AND HSS STEEL E 3/8" x 81/4" tel 206I hnuckl s@harr13 4 hnuckles@harriottvalentine.com I HSS COLUMN PER PLAN AT RIM. ATTACH SHEARWALL PER PLAN I .^� BLOCK SOLID BELOW HSS FOR TO RIM W/ (2) ROWS Project Architect I - TJI PER PLAN FULL BEARING 5/8 �� 0 THRU-BOLTS - @ „ 32 oc Patricia Brennan Architects 4515C Bagley Ave N BLOCK WEB SOLID HEADER PER PLAN (WHERE OCCURS) Seattle, WA 98103 WF BEAM BEARING ON HSS COLUMN N Project 3/4" = 1'-0" 5 3/4" = 1'-0" 6 3/4" = 1'-0" 8 Shen Federman 23310 Humber Lane Edmonds, WA 98020 3/16 TOP RAIL F.B. 2" x 1" Issue Date Issue Description 03/23/2023 Permit Submittal STANCHIONS F.B. 11/2% 11/2" 4" INFILL 1/8" 0 CABLE TYPICAL TJI FRAMING MAX. WF BEAM PER PLAN HSS PER PLAN IN THIS DETAIL PER BOT. RAIL F.B. 11/2" x 11/2" SEE 11/S3.3 FOR STANCHION, BLOCK ONE BAY FULL — AND 6/S3.3 2/S2.1 3/16 RAIL, INFILL, AND BASE E DEPTH @ 32"oc GLAZING TJI's PER PLAN BASE E AS AT BOT. LEFT W/ (6) 1/4" x 5" LONG CALLOUTS JOISTS PER PLAN Building Department Approval PER PLAN SDS SCREWS °1 1°1 z o � JOISTS PER PLAN RECEIVED KERF PLATE Apr 13 2023 /16"x 2 /2" w (2) 5/8" 0 THRU— BOLTS 3/16 CHANNEL 3/16 PER PLAN A35 PER SW SCHEDULE H2.5A AT EACH TJI J A34 @ EVERY OTHER JOIST A35 TO JOIST AT EA. BLOCK CITY M ETSERV DEVELOPMENT SERVICES DEPARTMENT Drawing Title STRUCTURAL DETAILS COUNTER —BORE STEEL E 3/8" x 10" BLOCK WEB SOLID . Z W CS16 @ EVERY OTHER STUD A34 AT EACH BLOCK NUT AND HEAD WOOD COLUMN PER PLAN AT RIM W/ THRU— WRAP UP EXT. F.O. STUD, AS REQUIRED BOLTS TO RIM SHEARWALL PER PLAN 1�4" 1�4" OVER PARAPET, AND DOWN CS16 @ EVERY OTHER STUD FOR FINISHES PER 8/S3.3 1" 1" INT. F.O. STUD (END LENGTH WRAP UP EXT. F.O. STUD, PER 6/S4.0) OVER PARAPET, AND DOWN Drawing Number �� BASE E 1/2" INT. F.O. STUD (END LENGTH WF BEAM BEARING ON WOOD COLUMN (KERF) SHEARWALL PER PLAN SHEARWALL PER PLAN PER 6/S4.0) S33 3/4 = 1 —0 � 3/4 = 1 —0 1 " 0 3 /16 3/4 = 1 —0 11 3/4 = 1 —0 12 " Lu z Lu 0 U) Lu z Q Lu 0 Lu ILL z LU 07 HV Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com 1-1 /2" = 1'-0" 1 1-1 /2" = 1'-0" 2 3/4" = 1'-0" 3 3/4" = 1'-0" 4 CP AT TOP FLANGE (AND AT (2) 3/4" 0 A325N BOTH CONTINUITY PLATES) (FOR ERECTION) PROVIDE 5/16" FILLET BELOW BACKING BAR 1" 2" IT E 3/8" A HAi? O r �oF WAS 5 /1s I BEAM PER PLAN `: ;±,� o o �F... 0 CP L Ado RgLy w� 3123123 TAB TO 1/4 BEAM WEB Project Contact Henry Nuckles AT BOTTOM FLANGE CP 664 hnuckles@harriottvalentine.com h ckl s@ arri REMOVE BACKING BAR, CP TAB TO BACKGOUGE, & PROVIDE COLUMN 5 5/16" FILLET Project Architect /16 Patricia Brennan Architects 4515C Bagley Ave N Seattle, WA 98103 CP (COMPLETE PENETRATION) WELD REQUIREMENTS SHEAR TAB — MOMENT FRAMES Project 3/4" = 1'-0" 5 3/4" = 1'-0" 6 3" = 1'-0" 7 1-1 /2" = 1'-0" 8 Shen Federman 23310 Humber Lane Edmonds, WA 98020 OIssue Date Issue Description 03/23/2023 Permit Submittal WF BEAM PER PLAN CP TOP AND BOTTOM --------------- tbf 1/4 SEE 7/S3.4 FOR CP WELD 3O REQUIREMENTS WOOD BEAM PER PLAN RAFTERS PER PLAN O5 �i BEVEL AS REQUIRED BY AWS D1.1. SHEAR TAB CONNECTION PER 8/S3.4 Building Department Approval O2 LARGER OF tbf OR 1/2". (+ 1/2 tbf, — 1/4tbf) ° (PLAN VIEW) O3 3/4 tbf TO tbf , 3/4" MIN. (f 1/4"). ° RECEIVED ® RADIUS 3/8" MIN. Apr 132023 O CITY LO M EDMONDS TSERV DEVELOPMENT SERVICES DEPARTMENT (4) 5/8"0 THRU—BOLTS 3 tbf (� 1/2„) WELD ACCESS HOLES @ BEAM GAGE ® CONTINUITY PLATES PER 11/S3.4 T TO MATCH BEAM 3O FLANGE WIDTH AND Drawing Title STRUCTURAL DETAILS 3/8" ° II ° tbf THICKNESS WF COLUMN PER PLAN o I o CP WF TO E>— �3/1 Drawing Number 3/8" WELD ACCESS HOLES MOMENT CONN. — COLUMN STRONG AXIS S143/4 „ = 1 —0 � 3/4 = 1 —0 1 � 1-1 /2 = 1 —0 11 3/4 = 1 —0 12 W z W 0 U) W z Q W 0 ILL z W 01 ■L 3/4" = 1'-0" STRAP SCHEDULE (NOT ALL USED) MARK END LENGTH NAILS NAIL SPACING CMST12 44" (98) 10d x 3" 13/4" CMST14 34" (76) 10d x 3" 13/4" CMSTC16 25" (58) 12d x 31/4" 11/2" CS14 19" (36) 8d x 21/2" 21/16" CS16 14" (26) 8d x 21/2" 21/16" CS18 12" (22) 8d x 21/2" 21/16" CS20 9" (16) 8d x 21/2" 21/16" CS22 8" (14) 8d x 21/2" 21/16" 1. 10d AND 12d DIAMETER = 0.148"; 8d DIAMETER = 0.131 ". 2. USE HALF OF THE REQUIRED NAILS IN EACH MEMBER BEING CONNECTED (i.e. IN EACH END LENGTH). HOLDOWN SCHEDULE MARK FASTENERS TO STUDS' ANCHOR EMBEDMENT LENGTH DIA.2 EPDXY' CAST—IN4 HDU2 (6) 1/4" 0 x 21/2" SCREWS (20) 1/4" 0 x 21/2" SCREWS 5/8" 7/8" 8" N/A 8" 6"5 HDU8 1. 10d AND 12d DIAMETER = 0.148"; 16d DIAMETER = 0.162". SCREWS SHALL BE SIMPSON "SDS" TYPE SCREWS, INSTALL PER SIMPSON RECOMMENDATIONS. 2. PROVIDE A36 OR A307 ALL —THREAD AT EPDXY AND CAST —IN ANCHORS. 3. PROVIDE SIMPSON "SET-3G" EPDXY PER GENERAL STRUCTURAL NOTES. SPECIAL INSPECTION IS REQUIRED. 4. AT CAST —IN ANCHORS PROVIDE HEAVY HEX NUT AT BOTTOM OF ALL —THREAD. HOOKED J—BOLT MAY BE USED FOR LTT HOLDOWNS. 5. NOTED EMBEDMENT FOR HDU8 ANCHORS IS INTO FOOTING BELOW STEMWALL. HDU8 ANCHORS MUST BE CAST —IN —PLACE. SHEATHING PER SW SCHEDULE a ONE-SIDED p SHEARWALL SHEATHING PER SW SCHEDULE TWO-SIDED OO —STAGGER ANCHORS SHEARWALL AT TWO—SIDED SHEARWALLS Q ANCHOR BOLT WITH PLATE SHEATHING PER SW WASHER PER SW SCHEDULE SCHEDULE (0.229"x 3" SQUARE) 1 TYPICAL SHEARWALL ANCHOR BOLT PLACEMENT 1-1/2" = 1'-0" 2 II II ii II II II �� II II SHEARWALL PER PLAN II II II � I :� II II II II II W I •: o PIROVIDE HALF OF SPECIFIED NAILS IN EACH END LENGTH A L L1 T : II II II A 111 II II TT T TI 7F - II II -1 W :I PROVIDE 15/8" MIN. END DISTANCE FOR NAILS SHEARWALL PER II PLAN II II II I ��I III I II II II TYPICAL STRAP HOLDOWN AT FLOOR 3/4" = 1'-0" 6 SHEARWALL PER PLAN a (2) STUDS MIN. — REFER TO PLAN FOR LOCATIONS WHERE BUILT—UP POST CONSISTS OF MORE STUDS HOLDOWN PER PLAN W/ SCREWS PER MFR. SPECS. (OR NAILS SIMILAR) CONCRETE STEMWALL PER PLAN (6" MIN. THICKNESS) ° AT EX. CONC. WALL a AT NEW CONCRETE WALL PROVIDE ALL —THREAD °a PROVIDE ALL —THREAD AND AND EMBED IN EPDXY m HEX NUT OR HEADED BOLT GROUT PER SCHEDULE W W NOTE: AND EMBED PER SCHEDULE PROVIDE 5" END (HOOKED J—BOLT MAY BE AND 13/4" EDGE USED FOR LTT HOLDOWNS) DISTANCE FOR ANCHORS (MIN.) TYPICAL HOLDOWN AT CONCRETE 3/4" = 1'-0" 10 SHEARWALL SCHEDULE (NOT ALL USED ON PLANS) MARK SHEATHING' STUDS AT ABUTTING PANEL EDGES2 PANEL EDGE NAILING3,4 RIM JOIST OR BLOCKING TO TOP PLATE BOTTOM PLATE ATTACHMENT SOLID RIM TJI RIM BOTTOM PLATE TO RIM JOIST BELOW4 ANCHOR BOLT TO CONCRETES SILL PLATE AT FOUND. SW1 15/32" CDX PLYWOOD 2x 8d @ Coc A35 @ 24"oc 16d @ Coc 16d @ Coc 5/8" 0 @ 48"oc 2x SW2 15/32" CDX PLYWOOD 2x 8d @ 4"oc A35 @ 15"oc 16d @ 4"oc 16d @ 4"oc 5/8" 0 @ 32"oc 2x SW3 15/32" CDX PLYWOOD 3x 8d @ 3"oc A35 @ 12"oc N/A — USE SOLID RIM 16d @ 3"oc 5/8" 0 @ 16"oc 2x SW4 15/32" CDX PLYWOOD 3x 8d @ 2"oc A35 @ 9"oc N/A — USE SOLID RIM 16d @ 2"oc 5/8" 0 @ 12"oc 2x SW5 15/32" CDX PLYWOOD BOTH SIDES 3x 8d @ 3"oc A35 @ Coc N/A — USE SOLID RIM (2) ROWS 16d @ 3"oc 5/8" 0 @ 12"oc 3x SW6 15/32" CDX PLYWOOD BOTH SIDES 3x 8d @ 2"oc A35 @ 41/2"oc N/A — USE SOLID RIM (2) ROWS 16d @ 2"oc 5/8" 0 @ 12"oc 3x 1. WALL SHEATHING SHALL CONSIST OF APA RATED PLYWOOD WITH SPAN RATING 24/0. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF PANELS. 7/16" APA RATED SHEATHING (OSB) MAY BE USED IN PLACE OF 15/32" CDX. 2. STUDS AT ABUTTING PANEL EDGES MAY CONSIST OF (2)2x STUDS IN PLACE OF 3x STUDS — NAIL (2)2x STUDS TOGETHER WITH BOTTOM PLATE ATTACHMENT NAILING. 3. BLOCK ALL PANEL EDGES W/ 2x4 FLAT, ATTACH W/ PANEL EDGE NAILING. TWO STUDS MINIMUM ARE REQUIRED AT EACH END OF ALL SHEARWALLS. END STUDS SHALL RECEIVE PANEL EDGE NAILING. INTERMEDIATE STUDS SHALL BE 2x STUDS. NAIL SHEATHING TO INTERMEDIATE FRAMING MEMBERS WITH 8d @ 12"oc. 4. 8d NAILS SHALL BE 0.131" DIAMETER x 21/2" (COMMON). 16d NAILS SHALL BE 0.135" DIAMETER x 31/2" (BOX). 5. ANCHORS TO CONCRETE SHALL CONSIST OF CAST —IN —PLACE ANCHOR BOLTS, EXPANSION BOLTS, EPDXY GROUTED ALL —THREADS, OR TITEN HD HEAVY DUTY SCREW ANCHORS. CAST —IN —PLACE ANCHOR BOLTS HAVE A 7" EMBED AND SHALL BE J—BOLTS OR SHALL HAVE A HEX NUT AT THE BOTTOM END. EXPANSION BOLTS SHALL HAVE 5" EMBED AND SHALL NOT BE USED AT STEM WALL LOCATIONS WITH EDGE DISTANCE LESS THAN 5" (INSTEAD, USE EPDXY GROUTED ALL —THREADS OR TITEN HD ANCHORS). EPDXY GROUTED ANCHORS SHALL HAVE 5" EMBED AND 21/2" MIN. EDGE DISTANCE. TITEN HD ANCHORS SHALL HAVE 31/2" EMBED AND 13/4" MIN. EDGE DISTANCE. AT ALL ANCHOR BOLTS, PROVIDE STEEL PLATE WASHERS THAT ARE A MINIMUM OF 0.229" (3 GAUGE) x 3"x 3" (SIMPSON BP5/8-3 OR SIMILAR). PLACE BOLTS PER ANCHOR BOLT PLACEMENT DETAIL. SHEARWALL PER PLAN NAILING TO MATCH BOTTOM PLATE NAILING PER SW SCHEDULE SHEARWALL PER PLAN SHEARWALL PE" n' ""' INTERSECTING NON—SHEARWA PANEL EDGE NAILING PER SW SCHEDULE NAILING TO MATCH BOTTOM PLATE NAILING PER SW SCHEDULE PANEL EDGE NAILING PER SW SCHEDULE AIAT' ING TO MATCH TOM PLATE NAILING SW SCHEDULE EL EDGE NAILING SW SCHEDULE TYPICAL SHEARWALL INTERSECTIONS TYPICAL DOUBLE TOP PLATE 'LAN MULTI —STUD PER PLAN WIiH NAILING PER GEN. NOTES TYPICAL MULTIPLE -STUD POST CONSTRUCTION 3/4" = 1'-0" 11 BLOCKING (OR JOIS PER FLOOR AND R01 DETAILS JOISTS PER PLAN (DIR. VARIES) FULL DEPTH BLOCKI (OR RIM AT EXTERI BLOCK ALL PANEL E SILL PLATE PER SW SCHEDULE TOM PLATE NAILING SW SCHEDULE PLATE CONNECTION SW SCHEDULE EL EDGE NAILING SW SCHEDULE HOR BOLTS & WASHERS SW SCHEDULE EL EDGE NAILING SW SCHEDULE a. L ° TYPICAL SHEARWALL SECTION 3/4" = 1'-0" 6'-0" MIN. BETWEEN SPLICES Harriott Valentine Engineers Inc. 1932 First Avenue, Suite 720 Seattle, Washington 98101-2447 tel 206 624 4760 fax 206 447 6971 www.harriottvalentine.com Project Contact Henry Nuckles tel 206 413 6664 hnuckles@harriottvalentine.com Project Architect Patricia Brennan Architects 4515C Bagley Ave N Seattle, WA 98103 Project 8 Shen Federman 23310 Humber Lane Edmonds, WA 98020 (8) 16d @ 4"oc STAGGERED EACH SIDE OF SPLICE (16d @ 12"oc ELSEWHERE) I I I CENTER SPLICE OVER S TUD TYPICAL TOP PLATE SPLICE CONSTRUCTION 3/4" = 1'-0" 12 3123123 Issue Date Issue Description 03/23/2023 Permit Submittal Building Department Approval RECEIVED Apr 13 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Drawing Title STRUCTURAL DETAILS Drawing Number S4mO w z w 0 w z 2E w 0 w H z w _ 07