Loading...
APPROVED ENG RESUB2 BLD2023-0401+Civil_Plan+9.8.2023_5.02.41_PM+3773322VICINITY MAP r C� rf � 1 ' iwest y Park J Puget Sound �' ��✓ I Edmonds Ale "1 I � J Wood; y .� MOUntlal' 23310 HUMBER LANE Terrace � + f • f r ' 1 I Lahe B i! EDMONDS CONSTRUCTION SEQUENCE NOTES 1. SCHEDULE A PRE -CONSTRUCTION MEETING THROUGH MYBUILDINGPERMIT.COM AND EMAIL ENGINEERINGPERMITS@EDMONDSWA.GOV 2 DAYS IN ADVANCE OF DATE REQUESTED. 2. REVIEW TEMPORARY EROSION AND SEDIMENT CONTROL NOTES. 3. CALL FOR UTILITY LOCATES. 4. INSTALL TESC MEASURES AND MAINTAIN DUST CONTROL WHILE PREVENTING DISTURBANCE OF ANY AREAS OF VEGETATION OUTSIDE THE CONSTRUCTION ZONE. 5. HAVE EROSION CONTROL MEASURES INSPECTED BY CITY OF EDMONDS ENGINEERING INSPECTOR. ALL TEMPORARY SEDIMENTATION AND EROSION CONTROL MEASURES MUST BE IN PLACE AND INSPECTED PRIOR TO ANY CONSTRUCTION OR SITE CLEARING. EROSION AND SEDIMENTATION CONTROL PRACTICES AND/OR DEVICES SHALL BE MAINTAINED UNTIL PERMANENT VEGETATION IS ESTABLISHED. 6. DEMOLISH EXISTING STRUCTURES. 7. ROUGH GRADE SITE AS REQUIRED TO INSTALL DRAINAGE FEATURES. 8. CLEAR, GRUB & ROUGH GRADE SITE. COMPOST AMEND AND REVEGETATE DISTURBED AREAS NOT SUBJECT TO ADDITIONAL SURFACE DISTURBANCE IMMEDIATELY AFTER ROUGH GRADING. OTHER EXPOSED AREAS SHALL BE STABILIZED PER EROSION CONTROL NOTES BELOW. 9. INSTALL UTILITIES AND OTHER SITE IMPROVEMENTS, INCLUDING FRONTAGE IMPROVEMENTS. 10. STABILIZE AND COMPOST AMEND ALL EXPOSED SOILS PRIOR TO REVEGETATION OF ENTIRE SITE. REFERENCE EDMONDS STANDARD DETAIL SD-642. 11. ESTABLISH LANDSCAPING AND PERMANENT VEGETATION. ALL TEMPORARY EROSION CONTROL MEASURES SHALL BE REMOVED UPON FINAL SITE STABILIZATION AND APPROVAL BY CITY INSPECTOR. EDMONDS GENERAL CONSTRUCTION NOTES SEE SHEET C1.2 TESC DETAILS / GENERAL NOTES NO. I DATE I BY REVISIONS EROSION CONTROL LEGEND LIMITS OF DISTURBANCE FILTER FABRIC FENCE (SILT FENCE) FF X X X STABILIZED CONSTRUCTION ENTRANCE CE CE CATCH BASIN INLET PROTECTION IP 13 INTERCEPTOR SWALE SEE COR DWG 504, TYPE A TEMPORARY SWALE TREE PROTECTION FENCING —0� (ORANGE FENCE) TP CHECK DAM CD MILZ ILZ STRAW WATTLES SW I USE AS NEEDED SUGGESTED STOCKPILE LOCATION SP / / I \ I II I SOIL EXPLORATION PIT, TYP. I REFERENCE DRAWINGS & REPORTS SEE C1.2 FOR TESC DETAILS / CONST. NOTES SEE C2.0 FOR DRAINAGE/BMP PLAN SEE C3.4 FOR ROAD DETAIL SEE C3.5 FOR STORM/BMP DETAILS SEE SHORT FORM CWSPPP PREPARED BY C.E.S. SEE DRAINAGE REPORT PREPARED BY C.E.S. SOIL AMENDMENT SPECIFICATION ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2019 SWMMWW BMP T.5.13 MAINTAIN TESC BMP'S N INSTALL AND MAINTAIN ALL TESC MEASURES ACCORDING TO 10 5 0 10 20 APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRUCTION. SCALE: 1"=10' I - - X'X .t�o CATCH BASIN / RIM=365.36 — — — — 12"PVC (N)IE=361.96 / 8"PVC (E)IE=362.74 I 12"PVC (S)IE=36? ^Z / II LOD, TYP. � � I EXIST. SIDE SEWER EASEMENT \ \ RECORDING #:I 2015338 I S88' 19'16"E 140.00'(P) — — — — — — —o- �— -X_ X CI`__ _x X X X SS VIDEO \ � 1 r \ I E \ \ / X 6" SIDE X (E) LANDSCAPE WALL — INSTALLED MARCH 2023- REFERENCE: MR 1-5 STORM DRAINAGE REPORT JULY 7, 2023 CIVIL ENGINEERING SOLUTIONS GEOTECH REPORT JANUARY 19,2023 GEOTECH CONSULTANTS APPLICANT BERNARD SHEN & CATHERINE FEDERMAN 23310 HUMBER LANE EDMONDS, WA 98020 / e . ram.... .... . ° d. e ip G a a I . A. e41 Fj O I IIX / s .d // I 6"�BH, 6'D O- 1 KAT A \ I 1 SHEN / FEDERMAN 00 \� RESIDENCE d._ I O °.. (2-STORY HOUSE) \ i b Tx co 0 d a A •d'•d d d d ° .° SP 1 < 3/4" /I /I / / / I I I I / II I / I M I.°. �• s° I A° d I�% II ° d a 4, r..-. d / P: a' d a e. G ..1`..:... � j ...:... A d a 4 d� d /' ....._ .e 4 4 ` , a :d• ..a _ I. 362 51 A e d d / -d' .L a�' a• �L.G / d� . > d d A • A. •e •a e• a .4 ° I• e d 1 n d a- a. d °• EO M a: : V �d a d d i A. a a I EX / ° %'� - �' SHED I D a A F' E - � d MO d ° e� d d' I .q . a >. t a: z• ° .. .. „ °• EX `' d 4. S •d• d Q d I .Q a n 4 •• a e >d ° ° .. .. ....:. _ R a. d ° I / ' T Aa IF `« t•• .... . ....... ... t. FF O —T— — X- ---_ FF / \ S88` 19' 16"E 140.00' ° \I \ \ \ \\ CATCH BASIN / RIM=366.30 / \ COVER WITHIN 24 1 2"PVC / HOURS TYPICAL (N)IE=362.74 (S)IE=362.97 LOD, TYP. / DkMOLITION UNDER SEPARATE PERMIT BLD2023-0402 l CALL 3 WORKING DAYS BEFORE YOU DIG 811 UTILITIES UNDERGROUND LOCATION CENTER (ID,MT,ND,OR,WA) SAFETY PRECAUTION SHALL BE IMPLEMENTED BY ELECTRIC - RED SEWER -GREEN GASIOIL- YELLOW CONTRACTOR(S) AT ALL TRENCHING IN SURVEY - PINK TEL/CATV-ORANGE ACCORDANCE PROPOSED -WHITE WATER -BLUE WITH CURRENT OSHA STANDARDS DATE: Jul 18, 2023 JOB# 2070 DRAFTED: SS DESIGN: DE DIGITAL SIGNATURE CIVIL ENGINEERING 102 NW CANAL STREET SEATTLE, WA 98107 PHONE:206.930.0342 DUFFY@CESOLUTIONS.US PSPNP�� TP ei u6HH �C:HFRRYI f NW1/4 SEC36 T27N R3E All CALL FOR LOCATES AT 1-800-424-555 OR 811 CA FF 3 /�I F / r IP E3 BAS I N 5.75 (W)IE=363.29 RESUB Sep 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES BLD2023-0401 DEPARTMENT APPROVED FOR CONSTRUCTION CITY OF EDMONDS 09/25/2023 CITY ENGINEERING DIVISION EROSION CONTROL PLAN SHEN / FEDERMAN RESIDENCE 23310 HUMBER LANE, EDMONDS, WA 98020 DRAWING NO: C1.0 00571300101000 BLD2023-0401 EDMONDS GENERAL CONSTRUCTION NOTES STRAW WATTLE DETAIL INLET PROTECTION DETAIL 1. ALL MATERIALS AND WORK SHOWN ON THESE PLANS SHALL CONFORM TO THE CITY OF EDMONDS STANDARD PLANS AND DETAILS, THE FOLLOWING SPECIFICATIONS AND CODES, AND ALL OTHER APPLICABLE LOCAL MUNICIPAL, STATE, AND FEDERAL CODES, RULES AND REGULATIONS: - CURRENT INTERNATIONAL BUILDING CODE (IBC) - 2022 WSDOT/APWA STANDARD SPECIFICATIONS FOR ROAD, BRIDGE AND MUNICIPAL CONSTRUCTION - 2019 WASHINGTON STATE DEPARTMENT OF ECOLOGY STORMWATER MANAGEMENT MANUAL FOR THE PUGET SOUND BASIN (CURRENT EDITION) 2. STANDARD PLAN AND TYPE NUMBERS INDICATED ON THESE DRAWINGS REFER TO CITY OF EDMONDS STANDARD DETAILS, UNLESS NOTED OTHERWISE 3. A COPY OF THESE APPROVED PLANS MUST BE ON THE JOBSITE WHENEVER CONSTRUCTION IS IN PROGRESS. 4. DEVIATIONS FROM THESE PLANS MUST BE APPROVED BY THE ENGINEER OF RECORD AND THE LOCAL GOVERNING AUTHORITY. 5. CONTRACTOR SHALL RECORD ALL APPROVED DEVIATIONS FROM THESE PLANS ON A SET OF "AS -BUILT" DRAWINGS AND SHALL SUMMARIZE ALL AS -BUILT CONDITIONS ON ONE SET OF REPRODUCIBLE DRAWINGS FOR SUBMITTAL TO THE OWNER PRIOR PROJECT COMPLETION AND ACCEPTANCE. A SET OF AS -BUILT DRAWINGS SHALL BE SUBMITTED TO THE CITY OF EDMONDS PRIOR TO FINAL APPROVAL OF THE BUILDING OCCUPANCY/FINAL PROJECT APPROVAL. 6. ELEVATIONS SHOWN ARE IN FEET. SEE SURVEY FOR BENCHMARK INFORMATION. 7. THE LOCATIONS OF EXISTING UTILITIES AND SITE FEATURES SHOWN HEREON HAVE BEEN FURNISHED BY OTHERS BY FIELD SURVEY OR OBTAINED FROM AVAILABLE RECORDS AND SHOULD THEREFORE BE CONSIDERED APPROXIMATE ONLY AND NOT NECESSARILY COMPLETE. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL UTILITY LOCATIONS SHOWN AND TO FURTHER DISCOVER AND PROTECT ANY OTHER UTILITIES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. CONTRACTOR SHALL VERIFY LOCATION, DEPTH, SIZE, TYPE AND CONDITION OF EXISTING UTILITY LINES AT CONNECTION OR CROSSING POINTS BEFORE TRENCHING FOR NEW UTILITIES. ENGINEER ASSUMES NO RESPONSIBILITY FOR THE COMPLETENESS OR ACCURACY OF THE EXISTING UTILITIES AND SITE FEATURES PRESENTED ON THESE DRAWINGS. ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF CONFLICTS THAT ARISE. 8. CONTRACTOR SHALL LOCATE AND PROTECT ALL UTILITIES DURING CONSTRUCTION AND SHALL CONTACT THE UNDERGROUND UTILITIES LOCATION SERVICE (1-800-424-5555) AT LEAST 48 HOURS PRIOR TO CONSTRUCTION. 9. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE PROJECT SITE BEFORE STARTING WORK AND SHALL NOTIFY OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 10. PIPE LENGTHS WHERE SHOWN ARE APPROXIMATE AND MAY CHANGE DUE TO FIELD CONDITIONS. 11. CONTRACTOR SHALL OBTAIN A COPY OF THE GEOTECHNICAL REPORT (WHERE APPLICABLE) AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE CONTENTS THEREOF. ALL SITE WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH THE RECOMMENDATIONS OF THIS REPORT. 12. STRUCTURAL FILL MATERIAL AND PLACEMENT SHALL CONFORM TO THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT. 13. SUBGRADE SOILS IN ALL AREAS WHERE RAIN GARDENS, INFILTRATION OR PERVIOUS PAVEMENT IS TO BE PLACED SHALL BE DELINEATED AND PROTECTED AT ALL TIMES FROM COMPACTIVE ACTIVITIES (i.e. HEAVY EQUIPMENT, STOCKPILING). 14. MANHOLES, CATCH BASINS, UTILITIES AND PAVEMENT SHALL BEAR ON MEDIUM DENSE TO VERY DENSE NATIVE SOIL OR COMPACTED STRUCTURAL FILL. IF SOIL IS DISTURBED, SOFT, LOOSE, WET OR IF ORGANIC MATERIAL IS PRESENT AT SUBGRADE ELEVATION, REMOVE AND REPLACE WITH COMPACTED STRUCTURAL FILL PER GEOTECHNICAL REPORT. 15. SEE SURVEY AND ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND LOCATIONS OF BUILDINGS, LANDSCAPED AREAS AND OTHER PROPOSED OR EXISTING SITE FEATURES. 16. SEE ARCHITECTURAL DRAWINGS FOR PERIMETER FOUNDATION DRAINS. FOUNDATION DRAINS SHALL BE INDEPENDENT OF OTHER SITE DRAIN LINES AND SHALL BE TIGHTLINED TO THE STORM DRAIN SYSTEM WHERE INDICATED ON THE PLANS. 17. ALL REQUIRED STORMWATER FACILITIES MUST BE CONSTRUCTED AND IN OPERATION PRIOR TO INSTALLATION OF ANY PAVEMENT UNLESS OTHERWISE APPROVED BY THE ENGINEER. 18. ALL ROOF DRAINS, PERIMETER FOUNDATION DRAINS, CATCH BASINS AND OTHER EXTERNAL DRAINS SHALL BE CONNECTED TO THE STORM DRAINAGE SYSTEM, UNLESS NOTED OTHERWISE. 19. ALL FOOTING DRAINS SERVING BUILDINGS, WALLS, ROCKERIES, ETC. SHALL CONNECT TO THE DRAINAGE SYSTEM DOWNSTREAM OF THE SITE STORMWATER DETENTION SYSTEM. 20. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS REQUIRED FOR INSTALLATION OF ALL SITE IMPROVEMENTS INDICATED ON THESE DRAWINGS. NO. I DATE I BY REVISIONS 21. A SEPARATE IRRIGATION PERMIT MUST BE OBTAINED FROM THE CITY PUBLIC WORKS DEPARTMENT. PRIOR TO FINAL CONSTRUCTION ACCEPTANCE, PROVIDE TO THE CITY WATER QUALITY TECHNICIAN, A COPY OF THE BACKFLOW TEST REPORT. TEST REPORTS CAN BE FAXED TO 425-744-6057 OR EMAILED TO JEFF.KOBLYK@EDMONDSWA.GOV. BACKFLOW TESTING SHALL BE COMPLETED BY THE OWNER ANNUALLY THEREAFTER. 22. AS A MINIMUM REQUIREMENT, ALL DISTURBED AREAS ON AND OFF SITE SHALL BE RETURNED TO THE EQUIVALENT OF THEIR PRECONSTRUCTION CONDITION IN ACCORDANCE WITH APPROPRIATE REQUIREMENTS AND STANDARDS. 23. ALL DISTURBED SOIL AREAS SHALL BE COMPOST AMENDED AND SEEDED OR STABILIZED BY OTHER ACCEPTABLE METHODS FOR THE PREVENTION OF ON -SITE EROSION AFTER THE COMPLETION OF CONSTRUCTION. SEE EROSION CONTROL PLANS FOR SPECIFIC GRADING AND EROSION CONTROL REQUIREMENTS. 24. THE CONTRACTOR SHALL KEEP OFF -SITE STREETS CLEAN AT ALL TIMES BY SWEEPING. WASHING OF THESE STREETS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL. 25. THIS PROJECT IS NOT A BALANCED EARTHWORK PROJECT. BOTH EXPORT AND IMPORT OF SOIL AND ROCK MATERIALS ARE REQUIRED. 26. SLOPE OF FINISHED GRADE SHALL BE CONSTANT BETWEEN FINISHED CONTOURS OR SPOT ELEVATIONS SHOWN. 27. FINISHED GRADE SHALL SLOPE AWAY FROM BUILDING WALLS AT MINIMUM 5% SLOPE FOR A MINIMUM DISTANCE OF 10 FEET. 28. CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL INSTALL AND MAINTAIN SHORING AND BRACING AS NECESSARY TO PROTECT WORKERS, EXISTING BUILDINGS, STREETS, WALKWAYS, UTILITIES AND OTHER EXISTING AND PROPOSED IMPROVEMENTS AND EXCAVATIONS AGAINST LOSS OF GROUND OR CAVING EMBANKMENTS. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR REMOVAL OF SHORING AND BRACING, AS REQUIRED. 29. CONTRACTOR SHALL OBTAIN APPROVAL FROM THE CITY AND FOLLOW CITY PROCEDURES FOR ALL WATER SERVICE INTERRUPTIONS, HYDRANT SHUTOFFS, STREET CLOSURES OR OTHER ACCESS RESTRICTIONS. CONTRACTOR SHALL NOT RELOCATE OR ELIMINATE ANY HYDRANTS WITHOUT FIRST OBTAINING WRITTEN APPROVAL FROM THE FIRE MARSHAL. 30. COORDINATE AND ARRANGE FOR ALL UTILITY CONNECTIONS, UTILITY RELOCATIONS AND/OR SERVICE INTERRUPTIONS WITH THE AFFECTED OWNERS AND APPROPRIATE UTILITY COMPANIES. CONNECTIONS TO EXISTING UTILITIES SHALL BE MADE ONLY WITH ADVANCE WRITTEN APPROVAL OF THE AUTHORITIES GOVERNING SAID UTILITIES. POST CONSTRUCTION SOIL DETAIL UNDISTURBED PLANTS UNDISTURBED TURF (LAWN) (SEE NOTE 1) AREAS (SEE NOTE 1) I UNDISTURBED NATIVE VEGETATION UNDISTURBED NATIVE SOIL 2" ORGANIC MULCH 3" OF COMPOST INCORPORATED INTO 5" OF SFTE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8") PLANTING BEDS TURF (LAWN) AREAS o" 8" UNDISTURBED TURF/LAWN/LANDSCAPE UNDISTURBED NATIVE SOIL 31. ALL UTILITIES SHALL BE PLACED UNDERGROUND. 32. EXISTING UTILITY LINES IN SERVICE WHICH ARE DAMAGED DUE TO CONSTRUCTION WORK SHALL BE REPAIRED AT CONTRACTOR'S EXPENSE AND INSPECTED AND ACCEPTED BY CITY OF EDMONDS AND OWNER'S REPRESENTATIVE PRIOR TO BACKFILLING. 33. NEW UTILITY LOCATIONS ARE GENERALLY SHOWN BY DIMENSION, WHERE NO DIMENSIONS ARE INDICATED, LOCATIONS MAY BE SCALED FROM DRAWINGS. FIELD ADJUSTMENTS SHALL BE APPROVED BY OWNER'S REPRESENTATIVE AND CITY. 34. FIELD STAKE ALL UTILITY STUBS AT THE PROPERTY LINE. 35. TRENCH BACKFILL OF UTILITIES LOCATED WITHIN THE CITY RIGHT-OF-WAY SHALL BE COMPACTED TO 95 %. COMPACTION TEST REPORTS SHALL BE PROVIDED TO THE CITY PRIOR TO PAVING. 36. WHERE NEW PIPE CLEARS AN EXISTING OR NEW UTILITY BY 6" OR LESS, PLACE ETHAFOAM 200 AS A CUSHION BETWEEN THE UTILITIES. 37. SEE MECHANICAL DRAWINGS (WHERE APPLICABLE) FOR CONTINUATION OF SITE UTILITIES WITHIN THE BUILDING. 38. SEE ELECTRICAL DRAWINGS (WHERE APPLICABLE) FOR EXTERIOR ELECTRICAL WORK. 39. SEE LANDSCAPE DRAWINGS (WHERE APPLICABLE) FOR SITE IRRIGATION SYSTEM. 40. PIPE MATERIAL AND SIGNAGE SUBMITTALS SHALL BE PROVIDED TO CITY ENGINEERING DIVISION FOR APPROVAL PRIOR TO INSTALLATION. STEEP SLOPE NOTE: AMENDED SOILS SHOULD NOT BE INSTALLED ON FINISHED SLOPES EXCEEDING 33%. AREAS EXCEEDING 33% SHALL BE STABILIZED PER THE ENGINEER/GEOTECH OF RECORD. GRASS: SEED OR SOD 1.75" OF COMPOST INCORPORATED INTO 6.25" OF SITE SOIL (TOTAL AMENDED DEPTH OF 9.5", FOR A SETTLED DEPTH OF 8") SUBSOIL SCARIFIED 4" BELOW = LL SUBSOIL SCARIFIED 4 BELOW COMPOST AMENDED LAYER _ COMPOST AMENDED LAYER (12" BELOW SOIL SURFACE) (12" BELOW SOIL SURFACE) 112„ OPTION 2 - AMEND IN PLACE OR STOCKPILE AND AMEND GENERAL NOTES: PLANTING BEDS TURF (LAWN) AREAS 1. AREAS OF NO DISTURBANCE 1 I II I a ^ SHALL BE FENCED AND EXISTING 2" ORGANIC i / i / i / i �IIIIIIII�II�II�Illa�I��QI � �� �� GRASS: SEED VEGETATION AND SOIL SHALL BE MULCH � � /�/�� 0" OR SOD PROTECTED FROM CONSTRUCTION I IllI 1=1 If TK IC I 1E 1a IMPACTS. IIIIIIIIIIIIIII II IIIIIIIIIIII 2, TO MEASURE SETTLED DEPTH, 6" IMPORTED 1�111=III=III-III=III=III 1�1�111=III=III=111�1 6" IMPORTED WATER SOIL SUFFICIENTLY TO TOPSOIL MIX III=III-III=��11- =1�-III=��1= TOPSOIL MIX FULLY SATURATE WITHOUT I �I 11=1 11=1 11=111-111-1 I� I F1 11=1 11=1 11=1 11� (COMPACTED III=111=III=11I� I �I I __I II1=1I �I11=I II -II IEl I I -III (COMPACTED CAUSING EROSION. DEPTH) I�III-III-III=III=III=III IEIrE111=III=1I1=1II I DEPTH) III=III=III-11111-1 6' IL1=11E�I 11-III=11=III 3. COMPOST SHALL MEET SPEC. REQUIREMENTS IN THE 2017 =L - i_T_- EDMONDS STORMWATER SUBSOIL IS = _I' I� SUBSOIL IS SCARIFIED 6" - = ADDENDUM (CHECKLIST 7). �_ - SCARIFIED 6" BELOW _ // BELOW 4, COMPACTION OF TOPSOIL (WHERE MOIL MIXTED I _ IMPORTED REQUIRED) TO BE TO 85% (MAX) TOPSOIL MIX ,/ 12"/ &, TOPSOIL MIX OF THE MAXIMUM DRY DENSITY OPTION 3 - IMPORT TOPSOIL PER MODIFIED PROCTOR TEST (ASTM D1557). 4� REVISIOJDATE CITY OF EDMONDS POST CONSTRUCTION SOIL APRILQUALITY AND DEPTH PUBLIC WORKS STANDEPARTMENT DETFst 189,1 APPROVED BY: R. ENGLISHSD- APPLICANT BERNARD SHEN & CATHERINE FEDERMAN 23310 HUMBER LANE EDMONDS, WA 98020 CONTOUR LINE (TYP) ANGLE TERMINAL `END UPHILL 24" TO 48" TO PREVENT FLOW AROUND WATTLE (TYP) WATTLE TRENCH, SEE NOTE 2 2" MIN 5" MAX UN -TREATED FAKE (TYP) AREA AVAILABLE FOR SPACING VARIES SEDIMENT TRAPPING SEE WATTLE SPACING (TYP) TABLE (TYP) WATTLE (TYP) SEE DETAIL SECTION A -A W WATTLE INSTALLATION ON SLOPES 2"x2"x24" UN -TREATED WOODEN STAKE (TYP) i -3" MIN _4" MAX 8" DIAMETER MIN WATTLE DETAIL 8" DIAMETER SPACING WATTLE TABLE SLOPE MAXIMUM SPACING 1H:1V 10'-0" 2H:1V 20'-0" 3H:1V 30'-0" 4H:1V 40'-0" >4H:1 V ONE RUN ONLY N CITES: 1. COMPOST WATTLES RECOMMENDED ON SLOPES. USE STRAW WATTLES IN PAVEMENT APPLICATION. 2. ON SLOPES, INSTALL WATTLES PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOURS. INSTALLATION SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 8-01.3(10). 3. RUNOFF SHALL NOT RUN UNDER OR AROUND ROLL. ADDITIONAL STAKING MAY BE NECESSARY TO PREVENT UNDERCUTTING. 4. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF. REMOVE SEDIMENT AND ACCUMULATIONS WHEN EXCEEDING 1/2 HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND SURFACE. REVISION DATE CITY OF EDMONDS JANUARY 2018 WATTLE INSTALLATION PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH ER-903 CONSTRUCTION ENTRANCE DETAIL _LS 4 TH IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: 0 THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O2 ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4. INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 * PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE CITY OF EDMONDS STABILIZED CONSTRUCTION JANUARY 2018 ENTRANCE _ PUBLIC WORKS STANDARD DEPARTMENT DETAIL s/ 189� APPROVED BY: R. ENGLISH ER-901 DATE: Jul 17, 2023 JOB# 2070 DRAFTED: SS DESIGN: DE DIGITAL SIGNATURE FILTER FABRIC FENCE DETAIL 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL NATIVE BACKFILL MATERIAL 0 N iD 1 N 0 I N 8„ FILTER FABRIC MATERIAL IN CON71NOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS -\ WIRE MESH FENCE TO SUPPORT FILTER FABRIC BURY BOTTOM OF FILTER MATERIAL 8" TO 12" 6' MAX NOTES: 1. CONTRACTOR DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ACTIVITY. CATCH BASIN FILTER SOCK WITH OVER FLOW HOLES (TYP) NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. REVISION DATE CITY OF EDMONDS TEMPORARY JANUARY 2018 SEDIMENT TRAP T PUBLIC WORKS FOR CATCH BASINS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH E R - 9 02 CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE FILTER FABRIC FENCE JANUARY 2018 CITY OF EDMONDS FILTRATION SYSTEMS PUBLIC WORKS STANDARD DEPARTMENT DETAIL c s t . 189� APPROVED BY: R. ENGLISH E R - 9 00 CIVIL ENGINEERING 102 NW CANAL STREET SEATTLE, WA 98107 PHONE:206.930.0342 DUFFY@CESOLUTIONS.US NW1/4 SEC36 T27N R3E RESUB Sep 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2023-0401 APPROVED FOR CONSTRUCTION CITY OF EDMONDS 09/25/2023 CITY ENGINEERING DIVISION TESC DETAILS GENERAL CONSTRUCTION NOTES SHEN / FEDERMAN RESIDENCE 23310 HUMBER LANE, EDMONDS, WA 98020 DRAWING NO: C1.2 00571300101000 BLD2023-0401 SANITARY SEWER (SEPARATE PERMITS) OLYMPIC VIEW SEWER & WATER DISTRICT (OVWSD) O -N/A O-4" SDR 35 PVC SANITARY SEWER @ MIN 2.0 %. CONNECT TO EXISTING SIDE -SEWER. REF. OVWSD DETAIL W-1A. SEPARATE PERMIT REQ. GSewer clean out required on the right of way side of the property line. Ref OVWSD Detail S-4. O-EXISTING SIDE SEWERS PROPOSED TO BE REUSED MUST BE LOCATED AND CCTV'D AND VIDEO PROVIDED TO DISTRICT FOR REVIEW. EXISTING SIDE SEWER REPAIRED BY CIPP MUST BE CCTV'D AND VIDEO PROVIDED TO DISTRICT FOR REVIEW. INCLUDES EXISTING LATERAL AS DIRECTED BY OVWSD WATER IMPROVEMENTS (SEPARATE PERMITS) OLYMPIC VIEW SEWER & WATER DISTRICT (OVWSD) 10 -1" x 1" WATER SERVICE AND METER PIT; CONFIRM WITH OVWSD. 0 11 -1.5" DIA POLY PRIVATE WATER SERVICE FROM METER PIT TO HOUSE @ MIN. INCLUDE TRACER WIRE GN/A STORM DRAIN 20 -4" STORM DRAIN @ MIN 2.0 % GRADE (ASTM D-3034 PVC) 21 -4" FOUNDATION DRAIN @ MIN. 1.0 %. INCL. BACKFLOW PREVENTION. 22 -N/A 23 --N/A 24 --N/A 0 0- N/A 29 -N/A STORM DRAIN STRUCTURES 30 -N/A O 31 -N/A O 32 -TYPE 1 CATCH BASIN WITH SOLID LID PER EDMONDS DETAIL SD-303. IF RIM TO INVERT DEPTH EXCEEDS 5.0 FEET, A TYPE 2 CB REQUIRED. 33 -N/A 35 -N/A 36 -6" WIDE DURASLOPE TRENCH DRAIN KIT OR EQUAL WITH GALVANIZED STEEL, TRAFFIC RATED GRATE. 37 -N/A 38 -N/A 39 -N/A 40 -N/A 41 -N/A 42 -N/A 44 -N/A G 0 0- N/A 49 -N/A STREET IMPROVEMENTS 60 -N/A 61 -N/A 62 -DRIVEWAY APPROACH PER EDMONDS DRIVEWAY DETAIL TR-546 (SEE SHEET C3.4). 10-foot RADIUS REQUIRED. 67 -N/A 71 -RESTORATION OF UTILITY PATCHES: UTILITY PATCHES WITH LESS THAN 20-FEET OF SEPARATION SHALL BE COMBINED AND FULL WIDTH OR HALF WIDTH OVERLAY WILL BE REQUIRED DEPENDING ON THE EXTENT OF DISTURBANCE. WHERE UTILITY PATCHES FALL ENTIRELY WITHIN ONE TRAVEL LANE, THE OVERLAY SHALL EXTEND TO THE CENTERLINE OF THE ROADWAY. WHERE UTILITY PATCH EXTENDS INTO BOTH TRAVEL LANES THEN A FULL WIDTH OVERLAY IS REQUIRED. NO. I DATE I BY I REVISIONS FLOW CONTROL BMP's 50 -DETAIL NDP-1 : COMPOST AMENDED SOIL TO ALL DISTURBED AREAS (SEE DOE BMP T5.13). TILL 2-3" OF COMPOST INTO UPPER 8" OF SOIL. LOOSEN COMPACTED SUBSOIL, IF NEEDED BY RIPPING TO 12" DEPTH. MULCH LANDSCAPE BEDS AFTER PLANTING. G -N/A 52-SPLASHBLOCK DIRECTED AWAY FROM STRUCTURE. MAXIMUM 700 sf ROOF PER DOWNSPOUT. MINIMUM 50 LF FLOWPATH TO PL REQUIRED. SEE EDMONDS DETAIL SD-633 ON SHEET C3.5. G-DISPERSAL TRENCH PER EDMONDS DETAIL SD-631 AND SD-632 - (SHEET C3.5). SEE PLAN FOR LENGTH. SOIL SUMMARY GLACIAL TILL WITH SHALLOW GROUNDWATER INFILTRATION NOT RECOMMENDED BY GEOTECHNICAL ENGINEER UTILITY SEPARATION REQUIREMENTS A MINIMUM OF T HORIZONTAL SEPARATION AND V VERTICAL SEPARATION IS REQUIRED BETWEEN THE DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC.) AND SEWER, WATER, AND STORM AND S FROM ANY CITY MAIN LINES. (E) LANDCAPE WALL INSTALLED MARCH 2O23- BOUNDARY & TOPO SURVEY PLOG ENGINEERING P.O. BOX 412 RAVENSDALE, WA 98051 PHONE 206-420-7130 www.PlogEngineering.com VERTICAL DATUM NAVD88 ESTABLISHED USING RTK GPS SEE SURVEY SOIL AMENDMENT REQUIRED COMPOST AMENDED SOIL REQUIRED ON ALL LANDSCAPED AREAS AFTER CONSTRUCTION. SEE NOTE 50 DISPERSION TRENCH FLOW CONTROL FOR 3,500 sf - SEE SIZING TABLE THIS SHEET - SEE EDMONDS DETAILS SD-631 & SD-632 - I TOP OF BOARD=360.5 BOTTOM=358.0 AMENDED SOIL SEE DETAIL C3.5- I 1 I I I [r DISPERSION TRENCH LENGTH I \ IMPERVIOUS AREA - STORMWATER INFILTRATION/SOILS SUMMARY UPDATED JULY 18, 2023 SOILS REPORT SUMMARY Impervious Area Spreadsheet (Stormwater) Shen/Federman Residence - 23310 Humber Lane, Edmonds, WA 98020 Site Area 12,600 sf 0.289 acres Existing impervious area Ex. impervious area to be demo'ed 3,595 sf Ex. imprevious area to remain sf total existing impervious = 3,595 sf Existing vegetated area 9,005 sf Proposed Impervious Area (on -site) Roof 3,094 sf Exposed driveway 567 sf Exposed front/side walkway 779 sf total new + replaced impervious = 4,440 sf Existing imprevious area to remain 0 sf Total proposed impervious = 4,440 sf Proposed vegetated area 8,160 sf 5' DRYWELL 36" DEPTH _ FOR FD 'ram 0 / I I Iw Q U) TYPE 1 CB RIM=360.5± IE OUT=358.2± N 25.0' MINIMUM VEGETATED FLOWPATH - o� p _Z L 1111111 Dispersion Length Sizing Table Max tributary Area (sf) 3500 SF Roof + driveway area tributary to dispersion 10 LF / 700 sf Unit Length Requirement 0.01429 Required minimum Length= 50 LF size based on 700 sf/10 LF APPLICANT BERNARD SHEN & CATHERINE FEDERMAN 23310 HUMBER LANE EDMONDS, WA 98020 DATE: Sep 07, 2023 JOB# 2070 DRAFTED: SS DESIGN: DE DIGITAL SIGNATURE gg2 SB 51 Infiltration recommendation? No: glacial till; shallow groundwater seepage Project Shen / Federman Residence NORTHWEST ROOF Depth of Test Pit Soil profile Density= Groundwater Grain Size gravel = very coarse sand = coarse sand = medium sand = fine sand = very fine sand = fines %= USCS soil: Date of digging: T and 3.5'-deep glacial till dense ■ seepage at 2.0'-deep, 3.5'-deep N/A N/A N/A N/A N/A N/A N/A dense, slightly gravelly, silty sand that has been glacially compressed Jan. 18, 2023 = 400 SF TO SPLASH -BLOCK ROOF CHART CALL FOR LOCATES AT 1-800-424-555 OR 811 Geotech consultant: Marc McGinnis, PE; Geotech Consultants, Inc. CATCH BASIN ODRIVEWAY GRADE SHALL NOT RIM=365.36 EXCEED 14% PER ECDC 1880.060. 1 2"PVC (N)IE=361.96 y I 8"PVC (E)IE=362.74 / 12"PVC (S)IE=362.03 3 / I / I I / EXIST. SIDE SEWER EASEMENT \ RECORDING #:I 2015338 SS VIDEO 7 S88` 19' 16"E 140.00'(P) _ _ \ \ 41' SS S - - - cn a �' �° ~ 4-(2 , 4 �F,. \ /SSG O ��� F SS Co IE=360.7± - EX 6" SS �O (E) IE=352.8 IE=357.0± :•• .: a .. • E �.' ,• MIN 2' COVER REQ. FOR ALL PIPES Ad UNDER DRIVABLE SURFACES AND ' '. • d •�. d 1' COVER UNDER LANDSCAPED ♦`" d'� . n! � •d AREAS TYP. tA �• •,d d Lb RIM=363.1 (. �....,�•: +I ch.. a. 8D/o; I E=360.7 �' : • A : • •. (� e d M y. SHEN/FEDERMAN : j: A` 4 AA p_ f •. d :.. .. i. - his RESIDENCE a +E] D� C� A 00 „1 70 23310 HUMBER LANE of EDMONDS, WA 98020 BLD2023-0401 �1< \ co MAIN FLOOR = 363.5± `� 20 I \ _ Imo,• I I (n FIRE SPRINKLERS REQ 1E,35g9+ I SEPARATE PERMIT REQ II E I \1\�L7L' 20 4" SID u_ 11 o N 10 45 LF 1E,3 _ Asphg1t is the �s 5g•5+ only )hard surface permitted in the I rigN of way. Concrete maybe _ used p to the prop line. ... Rspfialt only .. / .�. " :... : y�. 0�: • .. .. 6"DBH, . %DJ-R . CHERRY F'LU S88° 19' 16"E 140.00' ° N 10 5 0 10 20 SCALE: 1 "=10' CATCH BASIN i RIM=366.30 12"PVC (N)IE=362.74 (S)IE=362.97 I i COMPLIES WITH APPLICABLE CITY STORM CODE O \� 09/12/2023 I \` CIVIL ENGINEERING 102 NW CANAL STREET SEATTLE, WA 98107 PHONE:206.930.0342 DUFFY@CESOLUTIONS.US NW1/4 SEC36 T27N R3E SOUTH/EAST ROOF = 2,700 SF TO DISPERSION TRENCH CATCH BASIN RIM=365.75 8"PVC (W)IE=363.29 PLEASE NOTE: As Humber Lane was paved within the last 5 years,.Final restoration will require a full width 20' grind and overlay per trench � / I N P / PP / NON -CUT STREET / FEE REQUIRED / PAVEMENT CUT AREA / =60SF -- J- ----- --- EX PP 71 O�ERLAY CUT & CAP EX SERVICE -SEPARATE PERMIT WITH O.V.W.S.D. FEE REQ. PAVEMENT CUT AREA -_ -- =80SF i 71 OVERLAY EXISTING FAILING, DAMAGED, OR NON-ADA COMPLIANT FRONTAGE IMPROVEMENTS SHALL BE REMOVED AND REPLACED AS DETERMINED BY THE CITY ENGINEERING INSPECTOR. APPROVED FOR CONSTRUCTION CITY OF EDMONDS 09/25/2023 DRAWING NO: DRAINAGE / BIVIP PLAN C2.0 SHEN / FEDERMAN RESIDENCE 00571300101000 23310 HUMBER LANE, EDMONDS, WA 98020 BLD2023-0401 (FOR FUTURE DEVELOPEMENT) PLACE 2X4 AT END OF SIDE SEWER STUB AND CUT TO LENGTH TO INSURE 3 FEET EXTENDS ABOVE GRADE. PAINT TOP 18 INCHES WHITE. IN 3 INCH HIGH LETTERS STENCIL THE NUMBER OF EVEN FEET FROM GROUND ELEVATION TO THE SEWER STUB INVERT. 8 GAUGE WIRE TO BE DOUBLE WRAPPED AROUND PIPE AND 2X4 STAKE AT OR ABOVE FINISHED GRADE. w Z LOCKING LAMPHOLE COVER TO BE PLACED AT FINISHED GRADE (SEE STD SEWER Of CLEANOUT DETAIL) Iry 0_ I INSTALL BURIED Z METALLIC MARKER TAPE : I 3' ABOVE PIPE. TAPE 6" WYE AND 45' BEND SHOULD READ "CAUTION BURIED SEWER BELOW". 6" LATERAL SEWER LINE CARLTON IND., `n SLOPE— 2% MIN. TO BLACKBURN MFG. CO. OR 50% MAX EQUAL. 1 6" SEWER LATERAL SHALL BE THE----6" TEE. PVC PLAIN END SAME MATERIAL AS THE MAIN LINE ." 45' ANGLE OR OTHER APPROVED (EXCEPT CONCRETE) PVC, EPDXY MAX. WATERTIGHT PLUG LINED D.I., C900 OR HDPE. CONCRETE POURED I SEWER MAIN IN PLACE FOR �{ 1' SEWER LATERAL NOTES: OVER 15% SLOPE 1. CONTRACTOR TO PROVIDE ALL MATERIALS, TRAFFIC CONTROL, PERMITS, FLAGGING, SHORING AND MISCELLANEOUS WORK TO TAP THE MAIN AND INSTALL THE SIDE SERVICE. 2. FOR DUCTILE IRON PIPE IN RIGHT— OF —WAY & EASEMENTS, USE RESTRAINING DEVICE AS SPECIFIED BY THE DISTRICT. 3. FOR TAPS ON: DI USE SST ROMAC, SMITH BLAIR, OR FORD TAPPING TEE. PVC, USE ROMAC CB TEE W/SST CLAMP, HDPE CONSULT THE DISTRICT. 4. CONCRETE PIPE: CUT —IN A NEW TEE WITH MECHANICAL COUPLINGS. ROMAC STYLE "CB" SEWER SADDLE TAPS MAY ONLY BE USED ON CONCRETE PIPE IF GIVEN SPECIFIC DISTRICT APPROVAL. 5. PROVIDE DISTANCE IN FEET FROM TEE/SADDLE TO DOWNSTREAM MANHOLE TO THE DISTRICT. OLYMPIC VIEW WATER & SEWER DISTRICT REVISIONS STANDARD DETAIL TYPICAL SIDE SEWER DATE SCALE DWG NO. 11 /18/21 NTS S-2 NO. I DATE I BY REVISIONS IJ BUILDING BUILDINGLd Io CLEANOUT NOT to TO EXCEED 3FT FROM CLEANOUT WITH 45° 0- FOUNDATION BEND AND CAP w w I��GENERAL CLEANOUT—__=,, I NOT TO EXCEED 100' I� BETWEEN CLEANOUTS _, 2» ASPHALT SURFACE 6" RISERS �12" PVC SLEEVE PVC CAP. REMOVE GASKET PRIOR TO INSTALLATION. TYPICAL CLEANOUT_ UNDER ASPHALT 1�CLEANOUT (WYE W/ CAP _& LAMPHOLE COVER) 12 LAMPHOLE COVER w TO MATCH EXISTING o w GRADE 0_ J �12" PVC SLEEVE 6" RISER " WYE AND 45' BEND _6" DISTRICT STUB 4" OR 6" SIDE SEWER CLEANOUT DETAIL AT PROPERTY LINE & BUILDING LAMPHOLE COVER NOTE: SIDE SEWER JOINTS SHALL BE GASKETED OLYMPIC VIEW WATER & SEWER DISTRICT REVISIONS STANDARD DETAIL SEWER CLEANOUT DETAIL DATE SCALE DWG NO. 11 /18/21 NTS S-3 APPLICANT BERNARD SHEN & CATHERINE FEDERMAN 23310 HUMBER LANE EDMONDS, WA 98020 j\�/ •' SEE COE STD DTL GU-410 ow Ld BEDDING MATERIAL (1-1/4" MINUS) CRUSHED SURFACEBASE COURSE (SEE NOTE 2 Ld IL 0- 6" MIN / // / FOUNDATION (IF REQUIRED) SEE NOTE 4 8" MIN If ­4 8" MIN SEE NOTE NOTES: 1. MAXIMUM WIDTH OF TRENCH AT TOP OF PIPE • 18" OR LESS FOR 6" AND SMALLER DIAMETER PIPE • 24" FOR 8" DIAMETER PIPE • 36" FOR 12" DIAMETER PIPE • O.D. PLUS 18" FOR PIPE LARGER THAN 12" NOMINAL DIAMETER 2. REFER TO DIVISION 9 OF WSDOT STANDARD SPECIFICATIONS FOR MATERIAL GRADATION AND ADDITIONAL INFORMATION. 3. TRENCH BACKFILL SHALL MEET A MINIMUM COMPACTION OF 95% DENSITY PER ASTM D 1557. 4. IF UNSTABLE MATERIAL IS ENCOUNTERED BELOW PIPE ZONE, CONTRACTOR SHALL REMOVE AND REPLACE AS REQUIRED BY CITY ENGINEER. REVISION DATE CITY OF EDMONDS APRIL 2021 TYPICAL TRENCH SECTION PUBLIC WORKS STANDARD DEPARTMENT DETAI L Fs} 189� APPROVED BY: R. ENGLISH GU-400 DATE: Jul 17, 2023 JOB# 2070 DRAFTED: SS DESIGN: DE DIGITAL SIGNATURE DRIVEWAY APPROACH (TYPE VI) A Ri Fly Y R/�qT� gpAgTF A Mql RpARpAF Rp�FO pO Rft v pN n �i�ygs -4soti \ R��TF A R0,9 pq<T N, Rp RoA O4 RADIUS DRIVEWAY APPROACH (WITHOUT CURB) O1 SAWCUT EDGE o a �00 EXISTING ASPHALT °' a STREET VARIES 2" HMA O2 2"-5/8" MINUS CSTC COMPACTED SUBGRADE 3O NOTES: SECTION A —A O1 SAWCUT AND USE TACK COAT BETWEEN ROAD TO DRIVEWAY APPROACH JOINT. SEAL JOINT WITH AR4000 SEALER. O2 DRIVEWAY APPROACH TO BE 2" HMA CLASS 1/2" PG 58H-22. O SUBGRADE SHALL BE COMPACTED TO 95% MAXIMUM DENSITY. O 10' EDGE RADIUS. OHMA SHALL BE PLACED FROM EDGE OF EXISTING STREET, A MINIMUM DISTANCE OF 20-FT OR TO PROPERTY LINE, WHICHEVER IS GREATER. O DRIVEWAY WIDTH TO BE MINIMUM 12'. _ REVISION DATE CITY OF EDMONDS DRIVEWAY APPROACH FEBRUARY 2023 TYPE VI PUBLIC WORKS STANDARD DEPARTMENT DETAIL APPROVED BY: R. ENGLISH T R— 5 4 6 CIVIL ENGINEERING' 102 NW CANAL STREET SEATTLE, WA 98107 PHONE:206.930.0342 DUFFY@CESOLUTIONS.US RESUB Sep 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2023-0401 APPROVED FOR CONSTRUCTION CITY OF EDMONDS ��vl_l 09/25/2023 vi r r vi Vl-"Wrlv NW1 /4 SEC36 T27N R3E ROAD DETAILS SHEN / FEDERMAN RESIDENCE 23310 HUMBER LANE, EDMONDS, WA 98020 DRAWING NO: C3.4 00571300101000 BLD2023-0401 NO. I DATE I BY REVISIONS FOOTING DRAIN DETAIL SOURCED FROM GEOTECH REPORT Slope backfill away from foundation. Provide surface drains where necessary. 4' min_ Backfill (See text for requirements) Nonwoven Geotextile Filter Fabric Tlghtline Roof Drain (Do not connect to footing drain) A 3 O �0 LL Possible Slab 4" Perforated Hard PVC Pipe (Invert at least 6 inches below slab or crawl space. Slope to dram to appropriate outfall. Place holes downward.) Vapor Retarder Barrier and Capillary BreaklDrainage Layer I Refer to Report text i NOTES: (1) In crawl spaces. provide an outlet drain to prevent buildup of water that bypasses the perimeter footing drains_ (2) Refer to report text for additional drainage, waterproofing, and slab considerations. GEOTECH ('0NS1,'LTAN N INC. '1"YP1C.-kL 1-004 M, Dit-UN 23310 Humber Lane Edmonds, Washington Job No: Date: Plate: 4 23011 Jan.2023 DISPERSION TRENCH DETAIL PROPERTY LINE/EASEMENT DISPERSION TRENC 10' X 2% LEVEL, SE 1 12" X 12" (MIN) GUTTER (TYP) VEGETATED FLOW AREA (YARD) DRAIN TH (SXE NOTE 1) \TRENCH ), LAP ATH TS ITHRD PER STD DETAIL SD-632 VEGETATED FLOW PATH, SEE NOTE 1 6" (MIN) 24" (MIN) { 15% � I IbU88��88 o�oO�D o0 GEOTEXTILE, SEE NOTE 2 DISPERSION TRENCH TYPE 1 OR 1-L CATCH BASIN W/SOLID COVER PER STD DETAIL SD-303 OR SD-304 PROPERTY LINE/EASEMENT PLAN NTS GENERAL NOTES: 1. REFER TO THE 2022 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK AND 15% MAX r' U 9 INFEASIBILITY REQUIREMENTS. OTES: 1. VEGETATED FLOW PATH MUST BE PROVIDED 4" IN) PERFORATED IN CCORDANCE THE 2022 CITY OF EDMONDS P UNDERDRAIN STO WATER ADDENDUM REQUIREMENTS. PE PER WSDOT 2 SPEC. 9-05.2(6), GEOTE ILE SHALL CONFORM TO WSDOT SPEC. LAID LEVEL 9-33.2( GEOTEXTILE FOR SEPARATION, NON-WOV TYPE. WASHED DRAIN ROCK, 3. WASHED DRAT ROCK SHALL CONFORM TO SEE NOTE 3 WSDOT SPEC. 03.12(5), GRAVEL BACKFILL FOR DRYWELLS. UNDISTURBED NATIVE SOIL CITY OF EDMONDS TYPICAL DOWNSPOUT DISPERSION TRENCHES PUBLIC WORKS FOR ROOFS DEPARTMENT APPROVED BY: R. LNGLISH APPLICANT BERNARD SHEN & CATHERINE FEDERMAN 23310 HUMBER LANE EDMONDS, WA 98020 R ISION DATE FEB ARY 2023 STAN RD DETAI L SD-631 DRYWELL DETAIL (SERVING FOOTING DRAIN) OBSERVATION PIPE MARKING TYPE 1 OR 1-L CATCH CENTER OF DRYWELL BASIN W/ SOLID LID PER 48" DIA. (MIN) DRYWELL CITY STANDARD DETAIL SD-303 OR SD-304 \ 4" (MIN) PERFORATED \ PVC UNDERDRAIN PIPE \ \I CLEANOUT Lu 5 \� T w (MIN) w Lj \ 0 a (MIN) GUTTER -\ 4" (MIN) PVC DRAIN PIPE (TYP) (MIN) 10' (MIN) PROPERTY LINE/EASEMENT PLAN j NTS 4" (MIN) PVC DRAIN PIPE PER WSDOT SPEC. 9-05.1(5), 1% (MIN) SLOPE TEST PLUG IN PLASTIC BOX MARKED "DRAIN" CLEANOUT 12" BUILDING WPVC 4" (MIN) PVC DRAIN PIPE PER 12" (MIN) IIIIIIIIII_I IIIII WSDOT SPEC. 9-05.1(5), POSITIVE TOPSOIL SLOPE .....................MIN) _MIN) GENERAL NOTES: z COI JOD 4" (MIN1. REFER TO THE 2017 CITY OF �0o PERFORBLE EDMONDS STORMWATER ADDENDUM ((QQ)) UNDERDRAIN FOR SETBACK (CHECKLIST 13) AND PIPE PER WSDOT PUSH -ON INFEASIBILITY REQUIREMENTS. SPEC. 9-05.1 (6) PVC TEE O ` 2. MINIMUM COVER DEPTHS ASSUME NO GEOTEXTILE, SEE NOTE 1 VEHICULAR LOADING. DESIGNER TO SPECIFY COVER DEPTHS IF VEHICULAR TRAFFIC ANTICIPATED. WASHED DRAIN ROCK, 3. PROVIDE 10 FEET (MIN) SPACING SEE NOTE 2 - BETWEEN DRY WELLS. NOTES: UNCOMPACTED NATIVE MATERIAL, SCARIFY 3" 1. PLACE GEOTEXTILE FABRIC ALONG WALLS AND TOP OF WASHED (MIN) 1' (MIN) ABOVE SEASONAL ROCK. GEOTEXTILE SHALL CONFORM TO WSDOT SPEC. 9-33.2(1), HIGH GROUNDWATER TABLE GEOTEXTILE FOR SEPARATION, NON -WOVEN TYPE. OR HYDRAULICALLY 2 WASHED DRAIN ROCK SHALL CONFORM TO WSDOT SPEC. RESTRICTIVE LAYER 9-03.12(5), GRAVEL BACKFILL FOR DRYWELLS. PROFILE 3. OBSERVATION WELL SHALL CONFORM TO WSDOT SPEC. NTS 9-05.2(6), PERFORATED PVC UNDERDRAIN PIPE. REVISION DATE TYPICAL DOWNSPOUT APRIL 2021 CITY OF EDMONDS INFILTRATION DRYWELL PUBLIC WORKS STANDARD DEPARTMENT DETAIL FSt. Jag° APPROVED BY: R. ENGLISH SD-638 DISPERSION TRENCH DETAIL 4"X4" SUPPORT POSTS END CAP OR PLUG TO KEEP GRADE BOARD CLEANOUT (TYP) LEVEL PERFORATED PVC QO UNDERDRAIN PIPE FLOW TO OTHER DISPERSION TRENCH(ES) IF NECESSARY �^ TYPE 1 OR 1-L CATCH TYPE 1 OR BASIN W/SOLID COVER 1-L CATCH PER STD DETAIL BASIN W/SOLID s a_. SD-303 OR SD-304 COVER PER �^ El�^ .f STD DETAIL SD-303 OR z SD-304 0 A � 00 nn PIPE FROM ROOF DOWNSPOUT NOTCHED GRADE BOARD, 2"x2" 10' (MIN) NOTCHES, 18" O.C. Q NTS �2" (TYP) 2" GRADE BOARD Lia" O.C_. GENERAL NOTES: NOTCHES (TYP) 1. REFER TO THE 2022 CITY OF EDMONDS NOTCH DETAIL STORMWATER ADDENDUM FOR SETBACK AND INFEASIBILITY REQUIREMENTS. 2% 12" PRESSURE TREATED GRADE BOARD VEGETATED FLOW PATH, SEE NOTE 1 NOTES: 12" 12" 20 AX.* 1. A VEGETATED FLOW PATH MUST BE PROVIDED MPX' 15%f� IN ACCORDANCE THE 2022 CITY OF EDMONDS STORMWATER ADDENDUM REQUIREMENTS. GALVANIZED GEOTEXTILE FABRIC I IOC I BOLT (TYP) I 2. GEOTEXTILE SHALL CONFORM TO WSDOT SPEC. 9-33.2(1) GEOTEXTILE FOR SEPARATION, ivy? Xa NON -WOVEN TYPE. o I li WASHED DRAIN z I f`�C I ROCK, SEE NOTE 3 3. WASHED DRAIN ROCK SHALL CONFORM TO L' N I I WSDOT SPEC. 9-03.12(5), GRAVEL BACKFILL I I I I 4" (MIN) PERFORATED FOR DRYWELLS. PVC UNDERDRAIN PIPE PER WSDOT SPEC. 4. IF TRENCH RECEIVES RUNOFF FROM 700 SF 9-05.2(6), LAID LEVEL, OF ROOF RUNOFF AREA OR LESS, THIS DEPTH I CENTERED IN TRENCH, SHALL BE 18". IF GREATER THAN 700 SF OF 6" (MIN) -J HOLES POINTING UP ROOF AREA, THIS DEPTH SHALL BE 24" GEOTEXTILE, SEE NOTE 2 4% PRESSURE TREATED SUPPORT POST UNDISTURBED NATIVE SOIL SECTION A NTS - REVISION DATE DOWNSPOUT DISPERSION FEBRUARY 2023 CITY OF EDMONDS TRENCH WITH NOTCHED PUBLIC WORKS GRADE BOARD FOR ROOFS STANDARD DEPARTMENT DETAIL Fs t . 1 age APPROVED BY: R. ENGLISH S D - 63 2 DATE: Jul 17, 2023 JOB# 2070 DRAFTED: SS DESIGN: DE DIGITAL SIGNATURE TYPE 1 CATCH BASIN SEE APPLICABLE STANDARD DETAILS FRAME AND GRATE PIPE ALLOWANCES PIPE MATERIAL MAXIMUM INSIDE DIAMETER REINFORCED OR 12" PLAIN CONCRETE ALL METAL PIPE 15" SOLID WALL PVC 15" (WSDOT STD SPEC 9-05.12.(1)) PROFILE WALL PVC 15" (WSDOT STD SPEC 9-05.12(2)) 5" ti S+ 5 \2", 4", 6", OR 12" TI NOTES: RISER SECTION 1. CATCH BASINS SHALL BE CONSTRUCTED IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 9-05.50(3). 2. AS AN ACCEPTABLE ALTERNATIVE TO REBAR, WELDED WIRE FABRIC HAVING A MIN. AREA OF 0.12 SQUARE INCHES PER �^ a��f FOOT MAY BE USED. WELDED WIRE FABRIC SHALL COMPLY 6^ \ 2?+ TO ASTM A497 (AASHTO M 221). WIRE FABRIC SHALL NOT 2 BE PLACED IN KNOCKOUTS. 4+ �Vr1/fir 3. APPLY NON -SHRINK GROUT TO INSIDE AND OUTSIDE OF ALL JOINTS, RINGS, RISERS AND FRAMES. �\ 4. ROUND KNOCKOUTS MAY BE ON ALL 4 SIDES, WITH MAX / DIAMETER OF 20". KNOCKOUTS MAY BE EITHER ROUND OR e "D" SHAPE. 0 o, 5. THE MAX DEPTH FROM THE FINISHED GRADE TO THE PIPE INVERT IS 5'-0". 6. THE TAPER ON THE SIDES OF THE PRECAST BASE SECTION AND RISER SECTION SHALL NOT EXCEED 1/2"/FT. 7.CATCH BASIN FRAME AND GRATE SHALL BE IN ACCORDANCE r a WITH STANDARD SPECIFICATIONS. MATING SURFACES SHALL BE FINISHED TO ASSURE NON -ROCKING FIT WITH ANY COVER POSITION. (MEASUREMENT AT THE TOP OF THE BASE) 8.VERTICAL EDGE OF RISER SHALL NOT BE MORE THAN 2" PRECAST BASE SECTION FROM VERTICAL EDGE OF CATCH BASIN WALL. EENE CITY OF EDMONDS CATCH BASIN TYPE IPUBLIC WORKS DEPARTMENT APPROVED BY: R. ENGLISH SPLASH -BLOCK DETAIL BUILDING ROOF DOWNSPOUT, j SEE NOTE 1 DOWNSPOUT EXTENSION 24" WIDE x 36" LONG x 6" THICK ROCK PAD OR SPLASHBLOCK, SEE NOTES 2 AND 3 VEGETATED FLOW PATH, ; SEE NOTE 4 �. GENERAL NOTES: 1. REFER TO THE 2022 CITY OF EDMONDS STORMWATER ADDENDUM FOR SETBACK (CHECKLIST 14) AND INFEASIBILITY REQUIREMENTS. NOTES: 1. MAXIMUM OF 700 SQUARE FEET OF ROOF AREA MAY DRAIN TO EACH SPLASHBLOCK. 2. SPLASHBLOCK MAY BE CONCRETE, PLASTIC, OR SIMILAR RIGID MATERIAL. 3. ROCK PAD SHALL CONSIST OF 4" STREAMBED COBBLES PER WSDOT SPEC. 9-03.11(2) OR WASHED DRAIN ROCK CONFORMING TO WSDOT SPEC. 9-03.12(5), GRAVEL BACKFILL FOR DRYWELLS. 4. A VEGETATED FLOW PATH MUST BE PROVIDED IN ACCORDANCE THE 2022 CITY OF EDMONDS STORMWATER ADDENDUM REQUIREMENTS. REVISION DATE CITY OF EDMONDS TYPICAL DOWNSPOUT FEBRUARY 2023 DISPERSION SPLASHBLOCK PUBLIC WORKS FOR ROOFS STANDARD DEPARTMENT DETAIL Fs t 189'3 APPROVED BY: R. ENGLISH S D - 63 3 CIVIL ENGINEERING 102 NW CANAL STREET SEATTLE, WA 98107 PHONE:206.930.0342 DUFFY@CESOLUTIONS.US NW1/4 SEC36 T27N R3E RESUB Sep 10 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2023-0401 APPROVED FOR CONSTRUCTION __CI TY OF EDM ON D S 09/25/2023 CITY ENGINEERING DIVISION STORMWATER & BMP DETAILS SHEN / FEDERMAN RESIDENCE 23310 HUMBER LANE, EDMONDS, WA 98020 DRAWING NO: C3.5 00571300101000 BLD2023-0401