Loading...
REV1 APPROVED BLD PLN BLD2023-0401+Architectural_Plan+10.27.2023_1.33.41_PM+3866508BUILDING CODE COMPLIANCE ENERGY NOTES ENERGY NOTES (CONT'D) GENERAL NOTES PROJECT INFORMATION CITY OF EDMONDS ADOPTED CODES IBC 2018 - INTERNATIONAL BUILDING CODE IRC 2018 - INTERNATIONAL RESIDENTIAL CODE IMC 2018 - INTERNATIONAL MECHANICAL CODE UPC 2018 - UNIFORM PLUMBING CODE IFC 2018 - INTERNATIONAL FIRE CODE 2018 WASHINGTON STATE ENERGY CODE WSDOT STANDARD SPECIFICATIONS EDMONDS COMMUNITY DEVELOPMENT CODE (ECDC) ZONING ANALYSIS ZONING ANALYSIS IN RS-8 ZONE: SETBACKS PER ECDC 16.20.030 IVIIIVIIVIUIVI LU I AHtZA: b,000 Jr FRONT YARD: 25'-0" MIN SIDE YARD: 7'- 6" MIN REAR YARD: 15'-0" MIN BUILDING HEIGHT MAXIMUM: 25'-0" MAXIMUM LOT COVERAGE: 35% PER ECDC 24.90.020 "COVERAGE DEFINITION" TOTAL GROUND COVERAGE OF ALL BUILDINGS OR STRUCTURES MEASURED FROM THE OUTSIDE OF EXTERNAL WALLS OR SUPPORTING MEMBERS FROM A POINT TWO AND ONE-HALF FEET IN FROM THE OUTSIDE EDGE OF A CANTILEVERED ROOF, WHICHEVER COVERS THE GREATEST AREA LOT AREA = 12,600 S.F. 35% OF 12,600 S.F. = 4,410 S.F. 4,410 S.F. ALLOWABLE LOT COVERAGE 2,963 S.F. PROPOSED LOT COVERAGE ZONING ANALYSIS (CONT'D) PROPOSED IMPERVIOUS SURFACE COVERAGE CONSTRUCTION TO FOLLOW 2018 WASHINGTON STATE RESIDENTIAL ENERGY CODE. UVtFi11AN(a5, 5'Xlti' tN I FiY C UVtFi, PRESCRIPTIVE OPTION FOR GROUP R OCCUPANCY FROM 4'X32' COVER @WEST FACADE 3,062 S.F. 2 TABLE 402.1.1 AND SECTION R503 FOR RESIDENTIAL ALTERATIONS AS FOLLOWS: UNCOVERED CONCRETE WALKWAYS 779 S.F. 1. BUILDING ENVELOPE: - INSULATION: DRIVEWAY 598 S.F. CEILINGSNAULTED: R-38 • CEILINGS/NON-VAULTED: R-49 TOTAL 4,439 S.F. 2 NEW EXTERIOR WALLS: R-21 • FLOORS: R-30 - GLAZING: PROVIDE THE FOLLOWING U-VALUES: BUILDING HEIGHT CALCULATIONS: MAX U-VALUE, VERTICAL .30 A = +362' 3. REPLACEMENT FENESTRATION: B = +363' PER WSEC R503.1.1.1 WHERE SOME OR ALL OF AN EXISTING C = +362' FENESTRATION UNIT IS REPLACED WITH A NEW D = +363' FENESTRATION PRODUCT, INCLUDING SASH AND GLAZING, TOTAL = 1450 THE REPLACEMENT FENESTRATION UNIT SHALL MEET THE AVERAGE GRADE = 362.5' (1450 / 4) APPLICABLE REQUIREMENTS FOR U-FACTOR AND SHGC IN ACTUAL = 387.36' TABLE R402.1.1. MAXIMUM = 387.5' 4. LIGHTING: (AVERAGE GRADE + 25') PER 2018 WSEC R404.1, NOT LESS THAN 90% OF LAMPS PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE • PRIOR TO CONSTRUCTION THE SURVEYOR SHALL HIGH -EFFICACY LAMPS. EXCEPTION: ALTERATIONS THAT ESTABLISH AVERAGE GRADE AS SPECIFIED IN REPLACE LESS THAN 50 PERCENT OF THE LUMINAIRES IN A ECDC 21.105.010, AND SHALL ESTABLISH A SPACE, PROVIDED THAT SUCH ALTERATIONS DO NOT REFERENCE DATUM POINT THAT WILL BE INCREASE THE INSTALLED INTERIOR LIGHTING POWER. UNDISTURBED AND CAN BE FREELY ACCESSED. BUILDING AIR LEAKAGE: • THE SURVEYOR SHALL LOCATE THE ELEVATION 5. PER WSEC R402: AIR LEAKAGE SHALL NOT EXCEED OF THE FIRST FLOOR PRIOR TO THE CITY 4 AIR CHANGES/HOUR AND SHALL BE TESTED AS SUCH. A UNDER -FLOOR INSPECTION. WRITTEN REPORT OF THE AIR LEAKAGE TEST RESULTS, • A FINAL LETTER OF HEIGHT CONFIRMATION SHALL SHALL BE SIGNED BY THE TESTING PARTY AND PROVIDED BE PROVIDED PRIOR TO FRAMING INSPECTION. TO THE BUILDING INSPECTOR PRIOR TO CALL FOR FINAL I -- - - - --I -- i +354� i I -❑- - a ❑ _ M i � I I r 40 EXIST. Ni I I BLOCK WALL 7. ENERGY CREDITS: PER WSEC TABLES 406.2 &406.3 ADDITIONS TO EXISTING BUILDING THAT ARE MORE THAN 500 SF BUT LESS THAN 5,000 SF OF HEATED FLOOR AREA REQUIRE 6.0 CREDITS. INCORPORATE THE FOLLOWING ENERGY CREDITS FROM TABLES 406.2 & 406.3 OF THE 2018 WASHINGTON STATE ENERGY CODE: (2.4) AIR LEAKAGE CONTROL & EFFICIENT VENTILATION (2.0 CREDITS) PROVIDE FANTECH HERO 120H HRV W/CONTROLLER FRESH AIR APPLIANCE MODEL #99400 (3.1) HIGH EFFICIENCY HVAC EQUIPMENT (1.0 CREDITS) MITSUBISHI AIR HANDLER HEAT PUMP P-SERIES / PVA-A36AA7 & PUZ-A36NKA7(-BS) (5.3) EFFICIENT WATER HEATING (1.0 CREDITS) PROVIDE VIESMANN VITOCELL 300-V / ENERGY STAR RATED UEF OF 0.91 AND PROVIDE GAS BOILER VIESMANN VITODENS 200-W / ENERGY STAR RATED AFUE 90% (6.1) RENEWABLE ELECTRIC ENERGY (2.0 CREDITS) PROVIDE 2400 KWH SOLAR VOLTAIC ENERGY PANELS INSPECTION. 6. UNDERCUT INTERIOR DOORS TO A MINIMUM OF 1/2" ABOVE THE SURFACE OF THE FINISH FLOOR COVERING TO ALLOW FOR AIR MOVEMENT. - ----` - -- -- -- FE - 140.00' EXIST. SIDE SEWER +365' - EASEMENT '-- o- o- ❑-❑-❑ ❑❑-❑ RECORDING i. ❑ 2015338 HEAT PUMP COMPRESSOR 7'-6" MIN SIDE YARD MAX 55 dBA PER SETBACK PER WN ECDC 5.30.040 ECDC 16.20.030 1 LO -- 1 +-362' - - _T ' - - 2'-0" O.H. B +363' T.O. GARAGE SLAB Al ELEVATION = 363.17' 25' 0" MIN N I I FRONT YARD SETB�CK PER ECDC 1620.030 6'-0" I I / DECK I I 15'-0" MIN I / COV R =j r REAR YARD SETBACK 14' 0" N _ J PER ECDC 16.20.030 Y PERVIOUS / - LU DECK - - EXIST. cn M DECOMMISSIONED -1 L0 0 I N WALL / N Ir w EXIST. 36" TALy r NEW (2) STORY SINGLE FAMILY RETAINING W/ LL LI- ] J,M III RESIDENCE W/ATTACHED GARAGE 23310 HUMBER LANE 0i / III LEVEL ONE FF ELEVATION = 363.23' 0 T.O. ROOF ELEVATION = 387.20' ' EXISTING I I -- I I N II i I SINGLE FAMILY RESIDENCE ' TO BE DEMOLISHED M ram: `� ci i° � � RAMP li DN II 2'-q" O.H. +362' L -t - 3' 0" O.H. ----------t-�-�� - - Ni I l i �------- _ _ 57'-3" � - - - - - - L 42'-8" _J ENTRY LO i EXIST"TOB I EXIST. I COVER c? I SHED TO I N I BE REMOVED CVI--------J +355 \\--- NORTH SITE PLAN 1/8" = 1'-0" APPROVED BY PLANNING Nov 21 2023 IE = 140.00' REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION BUILDING OFFICIAL Nov 09 2023 APPROVED DATE ALL WORK SUBJECT APPROVED TO FIELD PLANS MUST BE INSPECTION FOR ON JOB SITE CODE COMPLIANCE DRIVEWAY I (GRASS-CRETE) CP r SLOPE DRIVEWAY r N MAX 14% 1 II 24'-2" LINEAR I - DRAIN 1. CONTRACTOR SHALL VERIFY ALL EXISTING SITE DIMENSIONS, PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS MUST BE VERIFIED. 2. CONSTRUCTION TO FOLLOW BUILDING ENVELOPE COMPLIANCE METHOD: PRESCRIPTIVE OPTION III FOR GROUP R OCCUPANCY 3. ALL WOOD EXPOSED TO WEATHER, SUCH AS DECKS, RAILINGS, JOISTS, POSTS TO BE APPROVED PRESSURE -PRESERVATIVE- TREATED WOOD OR APPROVED WOOD OF NATURAL DECAY RESISTANCE PER IRC R317. 4. PROVIDE FIREBLOCKING, DRAFTSTOPS AND FIRESTOPS PER THE 2018 INTERNATIONAL RESIDENTIAL CODE R302.11 AND R302.12. 5. PROTECT INTERIOR MATERIALS ON SITE PRIOR TO INSTALLATION, COVER AS NECESSARY. 6. TEST MOISTURE LEVEL IN FRAMING PRIOR TO INSULATION & SHEET ROCK. 7. NO WOOD TO CONCRETE CONNECTIONS EXCEPT PRESSURE TREATED PLATES. 8. SEAL ALL PLUMBING, ELECTRICAL, AND OTHER PENETRATIONS OF WALLS AND FLOORS, AND SEAL JOINTS. 9. SEAL EXTERNAL CRACKS, JOINTS, ETC. W/CAULKING AND INSTALL PEST PROOF SCREENS. 10. VERIFY SMOKE DETECTOR AND/OR /CARBON MONOXIDE DETECTORS ARE LOCATED IN EACH SLEEPING ROOM, OUTSIDE EACH SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, AND ON EACH STORY OF THE DWELLING PER IRC R314.2.2 AND IRC R315.2.2. 11. DRYER TO VENT DIRECTLY TO OUTSIDE W/MAX.VENT LENGTH OF 25' AND MAX. TWO 90 DEGREE ELBOWS. 12. PROVIDE PRESSURE REDUCING VALVE & MAIN WATER SHUT-OFF ON WATER SUPPLY LINE. mom 30'-0" M I N PER SHERWOOD VILLAGE COVENANT DRIVEWAY R.O.W. (ASPHALT) / CONSTRUCT PER CITY OF EDMONDS STANDARD DETAIL TR-546 i i 6'-5 3/4" 00,CONTRACTOR TO VERIFY i DRIVEWAY CLEARANCES TO PRESERVE TREE DRIP LINE i DBH, 6'DLR 1 KATSURA/ TO BE RETAINED i i I I I I II o o °' N cEco I LOT 3'-0" O.H. / SLOPE I� I FOUNDATI6 WALLS @GRADE D +3 3' � � I 40'-11/4" 3 7'-6" MIN SIDE YARD SETBACK PER / ECDC 16.20.030 ----------------------------- Revision is the reduction of eve from T to 2' I ................................................. I : The following documentation shall be available on : i Revised sheets are: I- site for the building inspector: Site 1 I : ® COE APPROVED ARCHITECTURAL PLAN SET ■ I A4 i ■ ® COE APPROVED STRUCTURAL PLAN SET A5 A6 I ■ ■ ❑ COE REVIEWED CALCULATION PACKET A9 I : ❑ ENERGY CREDIT WORKSHEET : and ❑ SITE PLAN I Structural sheet S2.2 ■ ❑ CIVIL PLAN ■ ----------------------------' :❑ L ......... ii i 21. i°i i°iii : iNi D: iiTiiiTii2i ............. I I I I 6 DBH, 6 DLR 1b CHERRY PLUM / �� TO BE RETAINED +365' Ji DATUM POINT +366.74' TOP OF SS MANHOLE COVER II i i i i SITE OWNERS: BERNARD SHEN & CATHERINE FEDERMAN PROJECT ADDRESS: 23310 HUMBER LANE EDMONDS, WA 98020 LAND USE ZONE RS-8 ASSESSOR'S PARCEL NUMBER: 00571300101000 LEGAL DESCRIPTION: SHERWOOD VILLAGE BILK 001 D-00 - TR 10 OCCUPANCY GROUP: R3 TYPE OF CONSTRUCTION: V-B CONTRACTOR: DLH INC. 44021 SE TANNER RD STE A NORTH BEND, WA 98045-8840 LICENSE #: DLHIN`*072B5 CONTACT: JASON HOLUB PHONE: (425) 888-1853 VICINITY PLAN J NOTTINGHAM RD L C i �E SHEET INDEX SITE 1 SITE PLAN, PROJECT INFORMATION, ZONING NOTES, VICINITY PLAN SURVEY SITE SURVEY C1.0 EROSION CONTROL PLAN C1.2 TESC DETAILS C2.0 DRAINAGE / BMP PLAN Al FOUNDATION PLAN, CRAWLSPACE CALCULATIONS A2 LEVEL ONE PLAN, DOOR SCHEDULE A3 LEVEL TWO PLAN, DOOR SCHEDULE A4 ROOF PLAN, ROOF VENTILATION CALCULATIONS A5 EAST & SOUTH ELEVATIONS A6 WEST & NORTH ELEVATIONS A7 WINDOW SCHEDULE w A8 SECTIONS A & B A9 SECTIONS E & F m A10 CONSTRUCTION DETAILS w All CONSTRUCTION DETAILS m Al2 SIDING AND DOOR/WINDOW TRIM DETAILS A13 WINDOW & DOOR INSTALLATION DETAILS A14 LEVEL ONE DECK AND AWNING PLANS A15 LEVEL TWO DECK PLANS A16 EXTERIOR RAILING ELEVATIONS S1.0 - S2.2 STRUCTURAL DRAWINGS & DETAILS KEY B Al '- BUILDING SECTION SECTION DETAIL Al *ALL DIMENSIONS ARE TO N FACE OF FINISH UNLESS NOTED OTHERWISE N BLD2023-0344 Patricia Brennan A R C H I T E C T S 4515C Bagley Avenue North Seattle Washington 98103 Phone 206.328.2886 Fax 206,328,2981 A2 PERMIT REVISION Data: 10/27/2023 APERMIT CORRECTION Date: 07/18/2023 PERMIT SUBMITTAL Data: 03/23/2023 5 REGISTERED Shen -Federman Residence SITE ARCHITECT REVISION 23310 Humber Lane Oct 27 2023 PATRICIA LYNN BRENNAN CITY OF EDMONDS STATE OF WASHINGTON Edmonds� DEPARTMMENTENT WA 98020 DEVELOPMENT CES E D C A B A9 A8 A8 22'-10"+/- 53'-8" ENTRY COVER BELOW L ROOF PLAN NORTH ��77� 7_7 qG N FLOW I 'ER / I& PICAL 13'-6"+/- F ROOF VENTILATION CALCULATION THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED. EXCEPTION: THE NET FREE AREA SHALL NOT BE LESS THAN 1/300 OF THE AREA OF SPACE VENTILATED IF NOT LESS THAN 40 PERCENT AND NOT MORE THAN 50 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE RAFTER SPACE. (PER IRC R806.2) SOFFIT/EAVE VENTS: 0.05 SF OF VENTILATION PROVIDED PER 3" DIA. HOLE @ EAVE PER JOIST BAY = 7.07 SI X 1 = 7.07 SI/ 144 SI = 0.049 SF OF VENTILATION PER JOIST BAY JOIST BAYS: 53'-8" LF OF SOFFIT/EAVE VENT / 2'-0" = 27 JOIST BAYS SOFFIT/EAVE VENT STRIP CALCULATION: 2" CONTINUOUS / 22 GAUGE GALVANIZED METAL / 63% OPEN AREA / 5/32" ROUND ON 3/16" STAGGERED CENTERS ROOF AREA VENTILATING REQUIRED: 1,395 / 150 = 9.30 SQ.FT. (1) 2" X 21" VENT STRIP = 42 SQ.IN. PER JOIST BAY 42 SQ.IN. X 63% OPEN AREA = 26.46 SQ.IN. / 144 SCAN. = 0.18 SO. FT. VENTILATING AREA PROVIDED AT LOW POINT OF ROOF: (1) ROW OF 2" X 21" PER JOIST BAY = 0.18 SQ.FT. 0.18 SQ.FT. X 27 JOIST BAYS = 4.86 SQ.FT. VENTILATING AREA PROVIDED AT HIGH POINT OF ROOF: (1) ROW OF 2" X 21" PER JOIST BAY = 0.18 SQ.FT. 0.18 SQ.FT. X 27 JOIST BAYS = 4.86 SQ.FT. TOTAL SOFFIT VENTILATION AREA PROVIDED = 9.72 SQ.FT. B BUILDING SECTION Al 2 SECTION DETAIL Patricia Brennan A R C H I T E C T S 4515C Bagley WALL LEGEND Avenue North WALLS BELOW Seattle Washington 98103 *ALL DIMENSIONS ARE TO FACE OF FRAMING UNLESS Phone NOTED OTHERWISE 206.328.2886 Fax 206.328.2981 APERMIT REVISION Date: 10/27/2023 A PERMIT CORRECTION Date: 07/18/2023 PERMIT SUBMITTAL Date: 03/23/2023 5 REGISTERED Shen -Federman Residence ARCHITECT REVISION 23310 Humber Lane Oct 27 2023 A4 PATRICIA LYNN BRENNAN CITY OF EDMONDS STATE OF WASHINGTON Edmonds WA 98020 DEVELOPMENTSERVICES , DEPARTMENT 0 cf) 0 0 N r N W r J N m < 0c) U U W T_ W a H c� w X g 0 T LEVEL TWO T.O. PLATE ELEV = 381.63' LEVEL TWO T.O. SUB FLOOR ELEV = 373.42' LEVEL ONE T.O. SUB FLOOR ELEV = 363.17' ao AVERAGE GRADE = 362.5' EAST ELEVATION AVE GRA 1/4" = 1'-0" SOUTH ELEVATION 1/4" = 1'-0" (@ALL PANES/ DOORS, TYP.) 1 9'-01, X 8'-0" NW MODERN CLASSIC 7500 9'-0" X 8'-0" NW MODERN CLASSIC 7500 Patricia Brennan A R C H I T E C T S 4515C Bagley Avenue North Seattle Washington 98103 Phone 206.328.2886 Fax 206.328.2981 A2 PERMIT REVISION Date: 10/27/2023 PERMIT CORRECTION Date: 07/18/2023 PERMIT SUBMITTAL Dote: 03/23/2023 FPATRICIA D Shen -Federman Residence T REVISION -A -23310 Humber Lane Oct 27 2023NAN CITY OF EDMONDS ON Edmonds WA 98020 DEVELOPMENTSERVICESCES � DEPARTMENT O Cl) O O N O N W r J N CO F O U o r) U N LLJ Lu a { H 0 w X a 0 T LE' T.( ELI LE' T.0 ELI LE' T.( ELI 00 _ AVERAGE GRADE = 362.5' WEST ELEVATION 1/4" = 1 '-o° NORTH ELEVATION 1/4" = 1'-0" L��uuil muuuj Patricia Brennan A R C H I T E C T S & 4515C Bagley Avenue North Seattle Washington 98103 Phone 206.328.2886 Fax 206.328.2981 APERMIT REVISION Date: 10/27/2023 A PERMIT CORRECTION Date: 07/18/2023 PERMIT SUBMITTAL Dote: 03/23/2023 FPATRICIA D Shen -Federman Residence T REVISION -A -23310 Humber Lane Oct 27 2023NAN CITY OF EDMONDS ON Edmonds WA 98020 DEVELOPMENTSERVICESCES � DEPARTMENT SECTION E LOOKING NORTH 1/4" = 1'-0" 4 Al SLOPE 3 -0 2'-0" 2 1/4"/FT. O.H. O.H. T AVERAGE GRADE = 362.5' SECTION F LOOKING WEST 1/411 = 11-011 Patricia Brennan A R C H I T E C T S 4515C Bagley Avenue North Seattle Washington 98103 Phone 206.328.2886 Fax 206.328.2981 APERMIT REVISION Date: 10/27/2023 A PERMIT CORRECTION Date: 07/18/2023 PERMIT SUBMITTAL Dote: 03/23/2023 FPATRICIA D Shen -Federman Residence T REVISION -A -23310 Humber Lane Oct 27 2023NAN CITY OF EDMONDS ON Edmonds WA 98020 DEVELOPMENTSERVICESCES � DEPARTMENT