Loading...
RVWD BLD BLD2024-1426+Manufacturer_Specifications_and_Installation_Instructions+10.30.2024_8.20.56_AM+458934920/22/24 kW INCLUDES: • True Power" Electrical Technology • Two-line multilingual digital LCD Evolution- controller (English/Spanish/French/Portuguese) • 200 amp service rated transfer switch available • Electronic governor • Standard Wi-Fi° connectivity • System status & maintenance interval LED indicators • Sound attenuated enclosure • Flexible fuel line connector • Natural gas or LP gas operation • 5 Year limited warranty • Listed and labeled for installation as close as 18 in (457 mm) to a structure." 'Must be located away from doors, windows, and fresh air intakes and in accordance with local codes. FEATURES 1161 C A61 GENERAL' GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz G007042-10, G007042-11, G007043-10, G007043-1 1 (Aluminum - Bisque) - 22 kW 60 Hz G007209-10, G007210-10 (Aluminum - Bisque) - 24 kW 60 Hz INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen- erac's success in providing the most reliable generators possible. Generac's G- Force engine lineup offers added peace of mind and reliability for when it's needed the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. TRUE POWER"" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. TEST CRITERIA: ✓ PROTOTYPE TESTED ✓ NEMA MG1-22 EVALUATION ✓ SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby generators, Mobile Link Wi-Fi allows users to monitor generator status from any- where in the world using a smartphone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Users can connect an account to an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. L GENERAC Product shown with optional fascia kit CON US Or C U� US "C U' w Mobile LISTED Note: CETL or CUL certification only applies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are ETL or UL certified in the USA only. O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac mod- els. It provides optimized FAST RESPONSE to changing load conditions and MAXI- MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the small- est electronic component. O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line is offered with its own transfer systems and controls for total system compatibility. GENERAC 6 PROMISE GENERAC 20/22/24 kW tngine • Generac G-Force design • "Spiny-lok" cast iron cylinder walls • Electronic ignition/spark advance • Full pressure lubrication system • Low oil pressure shutdown system • High temperature shutdown Generator • Revolving field • Skewed stator • Displaced phase excitation • Automatic voltage regulation • EPA Certified for non -emergency applications • UL 2200 listed Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Integrated load management technology • Remote mounting Evolution'" Controls • AUTO/MANUAL/OFF illuminated buttons • Two-line multilingual LCD • Sealed, raised buttons • Utility voltage sensing • Generator voltage sensing • Utility interrupt delay • Engine warm-up • Engine cool -down • Programmable exercise • Smart battery charger • Main line circuit breaker • Electronic governor Unit • SAE weather protective enclosure • Enclosed critical grade muffler • Small, compact, attractive Features and Benefits Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings help the engine run cooler, reducing oil consumption and resulting in longer engine life. Rigid construction and added durability provide long engine life. These features combine to assure smooth, quick starting every time. Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. Shutdown protection prevents catastrophic engine damage due to low oil. Prevents damage due to overheating. Allows fora smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. Produces a smooth output waveform for compatibility with electronic equipment. Maximizes motor starting capability. Regulating output voltage to ±1 % prevents damaging voltage spikes. Allows unit to be used for demand response applications (excluding 20 kW units). For your safety. Transfers vital electrical loads to the energized source of power. Can be installed inside or outside for maximum flexibility. Capability to manage additional loads for efficient power management. Mounts near an existing distribution panel for simple, low-cost installation. Selects the operating mode and provides easy, at -a -glance status indication in any condition. Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences. Smooth, weather -resistant user interface for programming and operations. Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. Constantly monitors generator voltage to verify the cleanest power delivered to the home. Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. Verifies engine is ready to assume the load, setpoint approximately 5 seconds. Allows engine to cool prior to shutdown, setpoint approximately 1 minute. Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. Protects generator from overload. Maintains constant 60 Hz frequency. Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph (241 km/h). Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. Quiet, critical grade muffler is mounted inside the unit to prevent injuries. Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure. 20/22/24 kW Installation System • 14 in (35.6 cm) flexible fuel line connector • Integral sediment trap Connectivity (Wi-Fi equipped models only) • Ability to view generator status • Ability to view generator Exercise/Run and Total Hours • Ability to view generator maintenance information • Monthly report with previous month's activity • Ability to view generator battery information • Weather information GENERAC® Features and Benefits Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply piping. Meets IFGC and NFPA 54 installation requirements. Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for complete peace of mind. Review the generator's complete protection profile for exercise hours and total hours. Provides maintenance information for the specific model generator when scheduled maintenance is due. Detailed monthly reports provide historical generator information. Built in battery diagnostics displaying current state of the battery. Provides detailed local ambient weather conditions for generator location. 20/22/24 kW Generator Model Rated maximum continuous power capacity (LP) _ Rated maximum continuous power capacity (NG) Rated voltage Rated maximum continuous load current — 240 volts (LP/NG) Total Harmonic Distortion _ G007038-1 G007039-1 (20 kW) 20,000 Watts" 18,000 Watts` 83.3 / 75.0 G007042-10 G007043-10 (22 kW) 22,000 Watts" 19,500 Watts` 91.7 / 81.3 Main line circuit breaker 90 amp 100 amp Phase Number of rotor poles Rated AC frequency Power factor Battery requirement (not included) Unit weight (Ib / kg) Dimensions (L x W x H) in / cm Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load" Sound output in dB(A) at 23 ft (7 m) with generator in Quiet -Test'" low -speed exercise mode" Exercise duration GENERAC Specifications G007038-3 G007042-11 G007209-10 G007039-3 G007043-11 G007210-10 (20 kW) (22 kW) (24 kW) 20,000 Watts" 22,000 Watts" 24,000 Watts" 18,000 Watts' 19,500 Watts` 21,000 Watts' 240 83.3/75.0 91.7/81.3 100/87.5 Less than 5% 90 amp 1 100 amp 100 amp 2 60 Hz — 1.0 12 Volts, Group 26R 540 CCA minimum or Group 35AGM 650 CCA minimum 448 / 203 466 / 211 436 / 198 445 / 202 455 / 206 48 x 25 x 29 / 121.9 x 63.5 x 73.7 67 67 67 67 67 55 57 55 57 57 5 min Engine Engine type GENERAC G-Force 1000 Series Number of cylinders 2 Displacement 999 cc Cylinder block Aluminum w/ cast iron sleeve Valve arrangement Overhead valve Ignition system Solid-state w/ magneto Governor system Electronic Compression ratio 9.5:1 Starter 12 VDC Oil capacity including filter Approx. 1.9 qt/ 1.8 L Operating rpm 3,600 Fuel consumption Natural gas ft3/hr (m3/hr) 1/2 Load 204 (5.78) 228 (6.46) 164 (4.64) 203 (5.75) Full Load 301 (8.52) 327 (9.26) 287 (8.13) 306 (8.66) Liquid propane 0/hr (gal/hr) [L/hr] 1/2 Load 87 (2.37) [8.99] 92 (2.53) [9.57] 86 (2.36) [8.95] 92 (2.53) [9.57] Full LoadmA 130 (3.56) [13.481 142 (3.90) [14.771 136 (3.74) [14.151 A 142 (3.90) [14.771 Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7 in water column (0.87-1.74 kPa) for NG, 10-12 in water column (2.49-2.99 kPa) for LP gas. For BTU content, multiply 0/hr x 2500 (LP) or ft3/hr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG). Controls Two-line plain text multilingual LCD Simple user interface for ease of operation. Mode buttons: AUTO = I F--Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser. MANUAL Start with starter control, unit stays on. If utility fails, transfer to load takes place. OFF Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance messages Standard Engine run hours indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility adjustable (brownout setting) From 140-171 V / 190-216 V Future Set Capable Exerciser/Exercise Set Error warning Standard Run/Alarm/Maintenance logs 50 events each Engine start sequence Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration). Starter lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger Fault/Missing AC warning Standard Low Battery/Battery Problem Protection and Battery Condition indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection J011L_ Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed (@ 72 Hz)/rpm Sense Loss Shutdown Standard i High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring protection Standard Common external fault capability Standard Field upgradable firmware Standard Rating definitions - Optional Standby: Applicable for supplying backup power for the duration of the utility power outage with correct maintenance performed. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046, UL2200, and DIN6271). Maximum kilovolt amps and current are subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases approximately 3.5%for each 1,000 ft (304.8 m) above sea level; and also will decrease approximately 1%for each 10 °F (6 °C) above 60 °F (16 °C). "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. 20/22/24 kW Service Rated Automatic Transfer Switch Features • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to eight additional large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Main breakers are rated for 80% continuous load. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 313 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. Dimensions 200 Amps 120/240,1 e Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.8 30.1 10.5 13.5 6.9 cm 67.95 76.43 26.67 34.18 17.5 Wire Ranges Conductor Lug Neutral Lug Ground Lug 250 MCM - #6 350 MCM - #6 2/0 - #14 Model GENERAL® Switch Options G007039-1, G007039-3 (20 kW) G007043-10, G007043-11 (22 kW) G007210-10 (24 kW) No. of poles 2 Current rating (amps) 200 Voltage rating (VAC) 120/240, 10 Utility voltage monitor (fixed)' -Pick-up 80% -Dropout 65% Return to Utility' Approx. 13 sec ETL or UL listed Standard Enclosure type NEMA/UL 3R Circuit breaker protected 22,000 Lug range 250 MCM - #6 *Function of Evolution controller Exercise can be set to weekly, bi-weekly, or monthly W1 H2 H1 W2 DEPTH GENERAC 20/22/24 kW Available Accessories Model # Product Description G007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 °F (-18 °C). (Not nec- essary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if temperature regularly falls below 0 °F (-18 °C). G007103-1 Breather Warmer Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch Contact Kit G007027-0 - Bisque IFascia Base Wrap Kit G005703-0 - Bisque Touch -Up Paint Kit G006485-0 Scheduled Maintenance Kit G007005-0 Wi-Fi LP Tank Fuel Level Monitor The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not be needed. Not compatible with 50 amp pre -wired switches. The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch up the paint to protect from future corrosion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure. Generac's scheduled maintenance kit provides all the items necessary to perform complete routine maintenance on a Generac automatic standby generator (oil not included). The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring the LP tank's fuel level is an important step in verifying the generator is ready to run during an unexpected power failure. Sta- tus alerts are available through a free application to notify users when the LP tank is in need of a refill. G007000-0 (50 amp) Smart Management Module Smart Management Modules (SMM) are used to optimize the performance of a standby generator. It manages large elec- G007006-0 trical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can reduce (100 amp) the overall size and cost of the system. G007169-0 - 413 LTE Mobile Linku' Cellular The Mobile Link family of Cellular Accessories allow users to monitor generator status from anywhere in the world, using G007170-0 - Wi-Fi/ Accessories a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance alerts. Us - Ethernet ers can connect an account with an authorized service dealer for fast, friendly, and proactive service. With Mobile Link, users are taken care of before the next power outage. G007220-0 - Bisque Base Plug Kit Base plugs snap into the lifting holes on the base of air-cooled home standby generators. This offers a sleek, contoured appearance, as well as offers protection from rodents and insects by covering the lifting holes located in the base. Kit contains four plugs, sufficient for use on a single air-cooled home standby generator. Dimensions & UPCs Model UPC G007038 696471074185 G007039 696471074192 G007042 696471074208 G007043 696471074215 G007209 696471071511 G007210 696471084801 GENERAC° 727 [2, , Lan LEFT SIDE VIEW FRONT VIEW Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2022 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No. A0000937814 Rev. E 03/15/2022