Loading...
REVIEWED BLD2022-0923+Structural_Calculations+7.13.2022_11.07.19_AM+2986700BUILT engineering STRUCTURAL CALCULATIONS THESE PLANS BLD2022-0921 COVER ALL BLD2022-0922 Project: THESE PERMITS BLD2022-0923 Park Pine 614 Building A 614-616 5th Avenue S RECEIVED Edmonds, WA 98020 Architect: Citizen Design 10 Dravus St Seattle, WA 98109 Engineer: Built Engineering 539 Broadway, #305 Tacoma, WA 98402 Jul 19 2022 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT .,.,.,.,.,.,.,.,.,.,., REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT BUILT engineering CRITERIA Gravity roof dead total floor dead bldgs A TPO membrane 3/8" plywood wood battens 1/2" plywood 1-3/4x7-1/4 LVL @ 12" oc R38 Polyiso Spray Insulation 1/2" gyp. wallboard miscellaneous dead + snow vinyl flooring 6" MPP panel miscellaneous total dead + live 0.5 live snow 25.0 psf 1.1 0.2 1.5 3.7 1.5 2.2 1.3 11% 12.0 psf 37.0 psf 1.0 live residential 40.0 psf 18.5 1.5 7% 21.0 psf 61.0 psf %4use 10 psf for TJI floor balcony dead 2x decking 4.3 live residential 60.0 psf 2x6 @ 16"oc 1.7 miscellaneous 1.0 14% 7.0 psf total dead + live 67.0 psf walls cement fiber siding 2.5 1/2" plywood 1.5 2x6 @ 16"oc 1.7 R21 insulation 0.8 1/2" gyp. wallboard 2.2 miscellaneous 1.3 13% 10.0 psf 539 Broadway, #305 Tacoma, WA 98402 tel - 253-985-5008 9/23/2021 Page of BUILT engineering Lateral wind wind importance factor basic wind speed wind exposure topographical factor (Kzt) seismic seismic importance factor latitude longitude mapped spectral response accel. at short periods (Ss) seismic design category response modification factor (R) 1.0 98 mph B 1.00 1.0 47.806 ° -122.378 ° 1.284 g (from USGS) D 6.5 (plywood shearwalls) 539 Broadway, #305 Tacoma, WA 98402 9/23/2021 tel - 253-985-5008 Page of ¢�o Park Pine 614 Latitude, Longitude: 47.80560076,-122.37778011 FT Q Puget Sound Express _j Edmonds Shelleberger Marsh Creek Point Edwards Condominiums Go gle Date Design Code Reference Document Risk Category Site Class Pine St Edmonds City Park Alder St eWalnut Street Coffee Holly Dr o� .+ s D m DN Hemlock Way N V) Pine St OSHPD Alder St Walnut St Cedar St =r Spruce St Spruce St > � Hemlock St < U) Laurel St 9/2/2021, 9:06:12 AM ASCE7-16 11 D - Default (See Section 11.4.3) Type Value Description SS 1.284 MCER ground motion. (for 0.2 second period) St 0.451 MCER ground motion. (for 1.0s period) SMS 1.541 Site -modified spectral acceleration value SMt null -See Section 11.4.8 Site -modified spectral acceleration value SIDS 1.027 Numeric seismic design value at 0.2 second SA SID1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.545 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.655 Site modified peak ground acceleration TL 6 Long -period transition period in seconds SsRT 1.284 Probabilistic risk -targeted ground motion. (0.2 second) SsUH 1.409 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 2.079 Factored deterministic acceleration value. (0.2 second) S1 RT 0.451 Probabilistic risk -targeted ground motion. (1.0 second) S1 UH 0.504 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. S1 D 0.837 Factored deterministic acceleration value. (1.0 second) PGAd 0.734 Factored deterministic acceleration value. (Peak Ground Acceleration) CRS 0.911 Mapped value of the risk coefficient at short periods CR1 0.896 Mapped value of the risk coefficient at a period of 1 s CO D Pine St rt` Map data 02021 BUILT engineering SEISMIC DESIGN BLDG A ASCE 7-16 Equivalent Lateral Force Procedure Occupancy Category II Table 1-1 Seismic Design Category D Table 11.6-1 Importance Factor 1.00 Table 11.5-1 Site Class D Table 20.3-1 Ss 128.40 %g S1 45.10 %g Fa 1.20 Table 11.4-1 Fv 1.85 Table 11.4-2 Ct 0.02 Table 12.8-2 x 0.75 Table 12.8-2 hn 30.00 feet (height to highest level) SMs = Fa*Ss 1.5408 Eq. 11.4-1 SMi = Fv*S1 0.8344 Eq. 11.4-2 Sys = (2/3)*SMs 1.0272 g Eq. 11.4-3 SD1 _ (2/3)*SM1 0.5562 g Eq. 11.4-4 Period Ta = Ct*hn"x 0.2564 s Eq. 12.8-7 To 0.1083 s per section 11.4.5 Ts 0.5415 s per section 11.4.5 Sa 1.0272 g per section 11.4.5 R 6.5 Table 12.2-1 Do 3 Table 12.2-1 Cd 4 Table 12.2-1 Section 9.5.5 ok? Yes Table 12.6-1 Equivalent Lateral Force Procedure (section 12.8) Cs 0.1580 Eq.12.8-2 W, weight 69,741 lb per table below QE 11,021 lb Eq.12.8-1 Vertical Force Distribution (section 12.8.3) k = 1.00 Floor Floor Floor Wall Wall Total (LRFD) (ASD) Level Hx Area Wt. Wt. Length Wt. Wt. WxHx Cvx QE 0.7QE (ft) (ft2) (psf) (k) (ft) (k) (k) (k-ft) (%) (k) (k) roof 30.00 811 12 9.7 120 4.6 14.3 429.7 32.2 3.55 2.49 third 21.00 811 21 17.0 120 9.5 26.5 556.1 41.7 4.60 3.22 second 12.00 811 21 17.0 120 11.3 28.4 340.5 25.5 2.81 1.97 balcony 12.00 81 7 0.6 0 0.0 0.6 6.8 0.5 0.06 0.04 539 Broadway Ste. 305 Tacoma, WA 98402 tel. 253-985-5008 69.7 1333.0 100.0 11.02 7.71 9/22/2021 Page of WIND CRITERIA ASCE7-16Ch.27DirectionalProcedure V = 98 mph Kd = 0.85 Exposure = B G = 0.85 h = 30 ft KZt = 1.00 Roof Slope = FLAT : 12 = 0 ° PRESSURE COEFFICIENTS (Cp) Windward Wall = 0.8 Windward Roof = N/A Leeward Wall = -0.5 Leeward Roof = N/A 1 PRESSURE (PSF) q = 0.00256KZKZtKdV2 Ht Kz qz 0•6xGz1 Gh PWW PLW PWALL PROOF 0-15 0.57 11.9 7.1 4.9 3.7 8.6 15-20 0.62 13.0 7.8 5.3 3.7 9.0 20-25 0.66 13.8 8.3 5.6 3.7 9.4 25-30 0.70 14.6 8.8 8.8 6.0 3.7 9.7 N/A 30-35 0.73 15.3 9.2 6.2 3.7 10.0 35-40 0.76 15.9 9.5 6.5 3.7 10.2 40-45 0.79 16.5 9.9 6.7 3.7 10.5 45-50 0.81 16.9 10.2 6.9 3.7 10.6 BLDG A ROOF LATERAL - SEISMIC IN () *Rho = 1.3 *Plate = 9' *Wind = 4.75*9.7=46 sli -P.- cn Cb 6) N CD N C(n 1 O /\ /� W - m c 1�ml �J Y� C / \ C ) CSC CO N*�CA�1 00 CA N C) N in O Rxn Lwall Vplf SW OT HD H:W DL=(10* 12*20+9* 10*20)*.6=2.5K .5(1.6) 1.0(3.2) 40 40 12(40) 24(80) SW1 SW1 BLDC A THIRD FLOOR LATERAL - SEISMIC IN () *Rho = 1.3 *Plate = 9' *Wind = 9x9=81 mOw�Gr- x v x m W N w N� p N � cf) W O — O O v 01) j O cn �KN(nNN �(nN���CJI N W W W W Ul n bo N 0 j coco N 10�1 cn W 0 DL=(18'*10'20+10*21 "20+10'12 .5(1.6) L - 81(209) - L Rxn 1.3(3.7) 2.6(7.4) Lwall 40 40 Vplf 32(93) 65(185) SW SW1 SW1 OT - -(1.6) HD - - H:W - - BLDG A SECOND FLOOR LATERAL - SEISMIC IN () * Rho = 1.3 * Plate = 11' " Wind = 8.6*10'=86 �p0wa * x v D N-:,-MmwC--lLn W «N00 Ln ��C0000 �IW Uri V 00 cn CO * 1 lC: VJ m. C� N O � W rh. , <Ncn Ul U) � 1 W N � N �0 v W O W Cn O 77, DL=(10*30*15+20*21 *15+12*10* 15)*.6=7.5K Rxn 2.1(5.0) 4.2(10.0) Lwall 30 30 Vplf 70(167) 140(334) SW SW1 SW2 OT -(1.8) 1.5(3.7) HD - - H:W - - BLDG A. Column at garage entry, 50% vertical live+vehicle impact controling Shape: PIPE_5.OX Material: A53 Gr.B Length: 12 ft I Joint: N1 J Joint: N2 Envelope Code Check: 0.935 (LC 2) Report Based On 97 Sections A 20.204 at 0 ft 7.134atOft 23.181 at 2.75 ft k f(y) ksi -23.181 at 2.75 ft 6.016 at 0 ft Vy k -1.484at3ft M k-ft -13.543 at 2.75 ft D in 3.526 at 0 ft fa ksi 1.245atOft -.589 at 5.25 ft AISC 14th(360-10): ASD Code Check Direct Analysis Method Max Bending Check 0.935 (LC 2) Max Shear Check 0.167 (LC 2) Location 2.75 ft Location 0 ft Equation H1-1a Max Defl Ratio L/244 Bending Compact Compression Non -Slender Out Plane In Plane Fy 35 ksi Lb 12 ft 12 ft Pnc/om 87.916 k KL/r 78.059 78.059 Pnt/om 120.09 k Mn/om 16.592 k-ft L Comp Flange 12 ft Vn/om 36.027 k Tau—b 1 Cb 1.377 BUILDING A ROOF FRAMING KEY R1 BUILDING A THIRD FLOOR FRAMING KEY BUILDING A SECOND FLOOR FRAMING KEY S3 aFORTE'CM Roof, R1 1 piece(s) 4 x 10 DF No.1 PASSED FBI Overall Length: 12' 1' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. FBI Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1391 @ 1 1/2" 6563 (3.00") Passed (21%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1156 @ 1' 1/4" 4468 Passed (26%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 4029 @ 6' 1/2" 5740 Passed (70%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.169 @ 6' 1/2" 0.394 Passed (L/842) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.259 @ 6' 1/2" 0.592 Passed (L/549) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Bearing Length Supports Available Required Loads to Supports (Ibs) Accessories Dead Snow Total 1 - Trimmer - HF 3.00" 3.00" F 1.50" 485 906 1391 None 2 - Trimmer - HF 3.00" 3.00" 1 1.50" 485 906 1391 None Lateral Bracing Bracing Intervals comments Top Edge (Lu) 12' 1" o/c Bottom Edge (Lu) 12' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 12' 1" N/A 8.2 -- 1 - Uniform (PSF) 0 to 12' 1" 6' 12.0 25.0 roof System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 7/11/2022 10:37:07 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Paget/6 .IFORTE CM II�B R Second Floor, S11 1 piece(s) 14" T31@ 360 @ 16" OC PASSED 1 0 Overall Length: 20' 3 1/2 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1040 @ 20' 1" 1202 (2.25") Passed (87%) 1.00 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1028 @ 20' 1955 Passed (53%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 6413 @ 11' 6" 7335 Passed (87%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.526 @ 10' 4 13/16" 0.657 Passed (L/449) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.658 @ 10' 4 13/16" 0.985 Passed (L/359) 1.0 D + 1.0 L (All Spans) TJ-ProT" Rating 45 40 Passed • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 23/32" Weyerhaeuser EdgeT" Panel (24" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProT" Rating include: None. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Stud wall - HF 5.50" 4.25" 1.75" 194 778 972 1 1/4" Rim Board 2 - Stud wall - HF 3.50" 2.25" 1.75" 209 838 1047 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Lateral Bracing Bracing Intervals F Comments Top Edge (Lu) 3' 10" o/c Bottom Edge (Lu) 20' 1" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 20' 3 1/2" 16" 10.0 40.0 Default Load 2 - Point (PLF) 11' 6" 16" 100.0 400.0 third floor System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 7/11/2022 10:37:07 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 3/6 .IFORTE CM FBI EThird Floor, Tl piece(s) 2 x 8 HF No Overall Length: 3' 6' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. FBI Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 885 @ 1 1/2" 3645 (3.00") Passed (24%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 453 @ 10 1/4" 2175 Passed (21%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 667 @ 1' 9" 2234 Passed (30%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.008 @ 1' 9" 0.108 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 1 0.010 @ 1' 9" 0.162 Passed (L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Bearing Length Supports Available Required Loads to Supports (Ibs) Accessories Dead Floor Live Total 1 - Trimmer - HF 3.00" 3.00" F 1.50" 185 700 885 None 2 - Trimmer - HF 3.00" 3.00" 1 1.50" 185 700 885 None Lateral Bracing Bracing Intervals comments Top Edge (Lu) 3' 6" o/c Bottom Edge (Lu) 3' 6" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 3' 6" N/A 5.5 -- 1 - Uniform (PSF) 0 to 3' 6" 10' 10.0 40.0 floor PASSED System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 7/11/2022 10:37:07 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 4 / 6 .IFORTE CM 1 E[FI��Pa Third Floor, TJ1 1 piece(s) 9 1/2" T]I® 230 @ 16" OC Overall Length: 16' 7` All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 546 @ 2 1/2" 1183 (2.25") Passed (46%) 1.00 1.0 D + 1.0 L (All Spans) Shear (Ibs) 533 @ 3 1/2" 1330 Passed (40%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2178 @ 8' 3 1/2" 3330 Passed (65%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.362 @ 8' 3 1/2" 0.404 Passed (L/536) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.452 @ 8' 3 1/2" 0.808 Passed (L/429) 1.0 D + 1.0 L (All Spans) TJ-ProT"' Rating 46 40 Passed • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A structural analysis of the deck has not been performed. • Deflection analysis is based on composite action with a single layer of 23/32" Panel (24" Span Rating) that is glued and nailed down. • Additional considerations for the TJ-ProTm Rating include: 1/2" Gypsum ceiling, Perpendicular Partitions. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Stud wall - SPF 3.50" 2.25" 1.75" 111 442 553 1 1/4" Rim Board 2 - Stud wall - SPF 3.50" 2.25" 1.75" 111 442 553 1 1/4" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 5' o/c Bottom Edge (Lu) 16' 5" o/c •TJI joists are only analyzed using Maximum Allowable bracing solutions. -Maximum allowable bracing intervals based on applied load. Vertical Load Location Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 16' 7" 16" 10.0 40.0 floor PASSED System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 7/11/2022 10:37:07 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 5/6 .IFORTE CM Third Floor, T2 2 piece (s)s) 1 1/4" x 14" 1.3E TimberStrand® LSL PASSED Overall Length: 9' a i 8' 10' I, 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1028 @ 1 1/2" 5325 (3.00") Passed (19%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 716 @ 1' S" 9917 Passed (7%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2271 @ 4' 8" 11407 Passed (20%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.046 @ 4' 8" 0.303 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.057 @ 4' 8" 0.454 Passed (L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Trimmer - HF 3.00" 3.00" 1.50" 188 840 1028 None 2 - Trimmer - H F 3.00" 3.00" 1.50" 188 840 1028 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 9' 4" o/c Bottom Edge (Lu) 9' 4" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 9' 4" N/A 10.2 1 - Uniform (PSF) 0 to 9' 4" 3' 10.0 60.0 deck System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 7/11/2022 10:37:07 AM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 6/6 aFORTE'CM Roof, RJ 1 1 piece(s) 1 3/4" x 7 1/4" 2.0E Microllam® LVL @ 12" OC PASSED All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 372 @ 2 1/2" 2603 (3.50") Passed (14%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 338 @ 10 3/4" 2772 Passed (12%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1789 @ 10' 1/2" 4255 Passed (42%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.768 @ 10' 1/2" 0.983 Passed (L/307) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 1.137 @ 10' 1/2" 1.311 Passed (L/208) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 4% increase in the moment capacity has been added to account for repetitive member usage. Bearing Length Supports Available Required Loads to Supports (Ibs) Accessories Dead Snow Total 1 - Stud wall - SPF 3.50" 3.50" 1.50" 121 251 372 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1.50" 121 251 372 Blocking • rsiocKmg Panels are assumea to carry no ioaas appnea airectiy aoove mem ana me tuu ioaa is appnea to me memoer Deing aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 16' 1" o/c Bottom Edge (Lu) 20' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load ' Location (Side) Spacing Dead (0.90) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 20' 1" 12" 12.0 25.0 roof System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0.12/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 2 / 18 .I F O R T E CM MEMBER REPORT PASSED Second Floor, S1 1 piece(s) 5 1/2" x 9" 24F-V4 OF Glulam Overall Length: 16' 6' "�00 I is, 9" Q ❑2 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 7194 @ 3" 16088 (4.50") Passed (45%) 1.0 D + 0.7 E (All Spans) Shear (Ibs) 6978 @ 1' 1 1/2" 13992 Passed (50%) 1.60 1.0 D + 0.7 E (All Spans) Pos Moment (Ft-Ibs) 18926 @ 13' 6" 23760 Passed (80%) 1.60 1.0 D - 0.7 E (All Spans) Neg Moment (Ft-Ibs) -13328 @ 13' 6" 18315 Passed (73%) 1.60 0.6 D + 0.7 E (All Spans) Live Load Defl. (in) 0.327 @ 11' 10 3/8" 0.533 Passed (L/587) - 1.0 D + 0.7 E (All Spans) Total Load Defl. (in) 0.725 @ 10' 5 1/4" 0.800 Passed (L/265) -- 1.0 D - 0.7 E (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 10' 10 3/4". • Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 7' 4 3/8". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Bearing Length Loads to Supports (Ibs) Supports . Accessories Total Available Required Dead Seismic Total 1 -Trimmer - HF 4.50" 4.50" 2.01" 1584 8014/-8014 9598/ None 8014 8014 2 - Trimmer - HF 4.50" 4.50" 2.01" 1584 8014/-8014 9598/ one None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 16' 6" o/c Bottom Edge (Lu) 16' 6" o/c -Maximum allowable bracing intervals based on applied load. Dead Seismic Vertical Loads Location Tributary Width (0.90) (1.60) Comments 0 - Self Weight (PLF) 0 to 16' 6" N/A 12.0 1 - Point (lb) 2' 6" N/A 11657 seismic with overstrength 2 - Uniform (PSF) 0 to 16' 6" 18' 10.0 - wall abv 3 - Point (lb) 13' 6" N/A - -11657 seismic with overstrength System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 3 / 18 aFORTE'CM Second Floor, S2 1 piece(s) 5 1/2" x 13 1/2" 24F-V4 DF Glulam PASSED IL 19' 6" I All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 7683 @ 19' 9 1/2" 7683 (2.15") Passed (100%) 1.0 D - 0.525 E + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 7460 @ 18' 8" 20988 Passed (36%) 1.60 1.0 D - 0.525 E + 0.75 L + 0.75 S (All Span Pos Moment (Ft-Ibs) 37062 @ 13' 10" 52852 Passed (70%) 1.60 1.0 D 0.525E + 0.75 L + 0.75 S (All Spans) Neg Moment (Ft-Ibs) -17479 @ 13' 10" 41209 Passed (42%) 1.60 0.6 D + 0.7 E (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 19' 6". • Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 10' 5 3/4". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Bearing Length I Loads to Supports (Ibs) Total Available Required Dead Floor Live Snow Seismic Total Supports Accessories 1 - Hanger on 13 1/2" PSL beam 3.50" Hanger' 2.14" 2264 2405 1002 5509/-5509 11180/- See note' 5509 2 - Hanger on 13 1/2" PSL beam 3.50" Hanger' 2.15" 2266 2425 1011 5509/-5509 11211/- See note' 5509 • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • ' See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 19' 6" o/c Bottom Edge (Lu) 19' 6" o/c -Maximum allowable bracing intervals based on applied load. Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger MGU5.50-SDS H=13.5 4.50" N/A 24-SDS25212 16-SDS25212 2 - Face Mount Hanger MGU5.50-SDS H=13.5 4.50" N/A 24-SDS25212 16-SDS25212 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 4 / 18 Dead Floor Live Snow Seismic Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) (1.60) Comments 0 - Self Weight (PLF) 3 1/2" to 19' 9 1/2" N/A 18.0 -- -- -- 1 - Uniform (PSF) 0 to 20' 1" (Front) 18' 10.0 - - wall 2 - Uniform (PSF) 3' 4" to 16' 10" (Front) 3' 7.0 60.0 25.0 - balcony at floor above 3 - Point (lb) 3' 10" (Front) N/A - - - 10742 seismic with overstrength 4 - Point (lb) 13' 10" (Front) N/A - - - -10742 seismic with overstrength vertical reaction 5 -Point (lb) 3' 4" (Front) N/A 140 1200 500 from bracesupporting balcony of floor above vertical reaction 6 -Point (lb) 16' 10" (Front) N/A 140 1200 500 from bracesupporting balcony at floor above Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 5 / 18 .I F O R T E CM MEMBER REPORT PASSED Second Floor, S3 1 piece(s) 3 1/2" x 19 1/2" 24F-V8 DF Glulam L Overall Length: 21' 1 112 r r � 4' 3' 4' 6" (. a a a a bearing okay without All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. overStrength Design Results Actual @ Location Allowed Result Load: Combination (Pattern) [Group] Member Reaction (Ibs) 31299 @ 4' 9" 27300 (12.00") Failed (115%) 1.0 D + 0.525E + 0.75 L + 0.75 S (Adj S ans) r1 Shear (Ibs) 9687 @ 6' 10 1/2" 12058 Passed (80%) 1.00 1.0 D + 1.0 L (Adj Spans) [1] Pos Moment (Ft-Ibs) 8119 @ 10' 11 3/16" 44363 Passed (18%) 1.00 1.0 D + 1.0 L (Adj Spans) [1] Neg Moment (Ft-Ibs) -39512 @ 4' 9" 44363 Passed (89%) 1.00 1.0 D + 1.0 L (All Spans) [1] Live Load Defl.(in) 0.221 @ 0 0.317 Passed (2L/516) 1.0 D + 0.525 E + 0.75 L + 0.75 S (Alt Svans) 1 Total Load Defl. (in) 0.333 @ 0 0.475 Passed (2L/342) 1.0 D + 0.525 E + 0.75 L + 0.75 S (Alt Spans) 1 • Deflection criteria: LL (L,/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 5' 2 7/16". • Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 8' 10 11/16". • The effects of positive or negative camber have not been accounted for when calculating deflection. • Applicable calculations are based on NDS. System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Bearing Length Loads to Supports (Ibs) Total Available Required Dead Floor Live Snow Seismic Total Supports Accessories 1 - Column Cap - steel 12.00" 12.00" 13.76" 11890 13030 4573 11822/- 41315/ Blocking 11822 11822 2 - Column - SPF 5.50" 5.50" 2.05" -1425 5113/4164 390/-1239 7883/-7883 13386/- Blocking 14711 3 - Column - SPF 5.50" 5.50" 5.87" 5782 6657 2104 1893/-1893 16436/- Blocking 1893 4 - Column - SPF 5.50" 5.50" 1.66" 1578 2192/-476 603 323/-323 4696/ Blocking • blocking Panels are assumed to carry no loads applied directly above them and the Tull load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 21' 2" o/c Bottom Edge (Lu) 9' 8" o/c -Maximum allowable bracing intervals based on applied load. ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 6 / 18 Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Seismic (1.60) Comments 0 - Self Weight (PLF) 0 to 21' 1 1/2" N/A 16.6 -- -- -- 1 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 18' 10.0 - wall 2 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 10' 21.0 40.0 second floor 3 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 10' 21.0 40.0 third Floor 4 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 10' 12.0 - 25.0 - roof 5 - Point (lb) 0 (Front) N/A 2264 2405 1002 5509/-5509 Linked from: S2, Support 1 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB 0.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 7 / 18 aFORTE'CM Second Floor, S2 Deflection Check 1 piece(s) 5 1/2" x 13 1/2" 24F-V4 DF Glulam PASSED 1 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 4791 @ 19' 9 1/2" 5363 (1.50") Passed (89%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 4416 @ 18' 8" 13118 Passed (34%) 1.00 1.0 D + 1.0 L (All Spans) Pos Moment (Ft-Ibs) 22083 @ 10' 3/8" 33033 Passed (67%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.422 @ 10' 1/2" 0.650 Passed (L/554) 1.0 D + 0.75 L + 0.75 S (All Spans) Total Load Defl. (in) 0.786 @ 10' 1/2" 0.975 Passed (L/298) 1.0 D + 0.75 L + 0.75 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 0.99 that was calculated using length L = 19' 6". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Total 1 - Hanger on 13 1/2" PSL beam 3.50" Hangers 1.50" 2264 2405 1002 5671 See note ' 2 - Hanger on 13 1/2" PSL beam 3.50" Hanger' 1.50" 2266 2425 1011 5702 See note ' • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 19' 6" o/c Bottom Edge (Lu) 19' 6" o/c -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1-Face Mount Hanger OHU612-SDS3 4.00" N/A 16-SDS25300 8-SDS25300 2-Face Mount Hanger OHU612-SDS3 4.00" N/A 4 16-SDS25300 8-SDS25300 • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Dead Floor Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 3 1/2" to 19' 9 1/2" N/A 18.0 1 - Uniform (PSF) 0 to 20' 1" (Front) 18' 10.0 - - wall 2 - Uniform (PSF) 3' 4" to 16' 10" (Front) 3' 7.0 60.0 25.0 balcony at floor above vertical reaction 3 -Point (lb) 3' 4" (Front) N/A 140 1200 500 from bracesupporting balcony of floor above vertical reaction 4 -Point (lb) 16' 10" (Front) N/A 140 1200 500 from bracesupporting balcony at floor above ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 8 / 18 aFORTE'CM Second Floor, S3 Deflection Check 1 piece(s) 3 1/2" x 21" 24F-V8 DF Glulam PASSED r , 4' 6" 5' All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 23689 @ 4' 9" 27300 (12.00") Passed (87%) 1.0 D + 0.75 L + 0.75 S (All Spans) Shear (Ibs) 8514 @ 2' 6" 12985 Passed (66%) 1.00 1.0 D + 1.0 L (All Spans) Pos Moment (Ft-Ibs) 6075 @ 17' 11 3/4" 51450 Passed (12%) 1.00 1.0 D + 1.0 L (Adj Spans) Neg Moment (Ft-Ibs) -39527 @ 4' 9" 51450 Passed (77%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.138 @ 0 0.317 Passed (2L/828) -- 1.0 D + 0.75 L + 0.75 S (Adj Spans) Total Load Defl.(in) 0.239 @ 0 0.475 Passed (2L/476) 1.0 D + 0.75 L + 0.75 S (Adj Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 3 1/4". • Critical negative moment adjusted by a volume factor of 1.00 that was calculated using length L = 9' 11 1/4". • The effects of positive or negative camber have not been accounted for when calculating deflection. • Applicable calculations are based on NDS. Bearing Length Loads to Supports (Ibs) Total Available Required Dead Floor Live Snow Total Supports Accessories 1 - Column Cap - steel 12.00" 12.00" 10.41" 11902 12229 4220 28351 Blocking 2 -Column -SPF 5.50" 5.50" 1.62" -1422 5113 390/-54 5503/ Blocking 1476 1476 3 - Column - SPF 5.50" 5.50" 4.20" 5790 4995 1671 12456 Blocking 4 - Column - SPF 5.50" 5.50" 2.13" 1933 2903/-156 853 5656/ Blocking • 01ocKing Faneis are assumea to carry no ioaas appnea aireary aoove mem ana the ruu ioaa is appnea to me memoer Deing aesignea. • Uplift constraint has been released at support location 9' 11 3/4". Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 21' 2" o/c Bottom Edge (Lu) 12' 7" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 21' 1 1/2" N/A 17.9 -- -- 1 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 18' 10.0 - wall 2 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 10' 21.0 40.0 second floor 3 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 10' 21.0 40.0 third floor 4 - Uniform (PSF) 0 to 21' 1 1/2" (Front) 10' 12.0 - 25.0 roof 5 - Point (lb) 0 (Front) N/A 2264 2405 1002 Linked from: S2 Deflection Check, Support 1 ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 10 / 18 aFORTE'CM Second Floor, rim beam at entry canopy 1 piece(s) 5 1/2" x 7 1/2" 24F-V4 DF Glulam PASSED I All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1011 @ 2" 8181 (3.50") Passed (12%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 906 @ 11" 8381 Passed (11%) 1.15 1.0 D + 1.0 S (All Spans) Pos Moment (Ft-Ibs) 4278 @ 8' 9 1/2" 11859 Passed (36%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.429 @ 8' 9 1/2" 0.863 Passed (L/482) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.658 @ 8' 9 1/2" 1.150 Passed (L/314) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L = 17' 3". • The effects of positive or negative camber have not been accounted for when calculating deflection. • The specified glulam is assumed to have its strong laminations at the bottom of the beam. Install with proper side up as indicated by the manufacturer. • Applicable calculations are based on NDS. Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Total 1 - Stu�wall- 3.50" 3.50" 1.50" 352 659 1011 Blocking 2 - Stud wall - SPF 3.50" 3.50" 1.50" 352 659 1011 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 17' 7" o/c Bottom Edge (Lu) 17' 7" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 17' 7" N/A 10.0 1 - Uniform (PSF) 0 to 17' 7" (Front) 3' 10.0 25.0 canopy System : Roof Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 16 / 18 aFORTE'CM Third Floor, T1 2 piece(s) 2 x 8 HF No.2 PASSED 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. 0 Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 757 @ 1 1/2" 3645 (3.00") Passed (21%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 387 @ 10 1/4" 2175 Passed (18%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 571 @ 1' 9" 2234 Passed (26%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.006 @ 1' 9" 0.108 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 1 0.009 @ 1' 9" 0.162 Passed (L/999+) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Bearing Length Supports Available Required Loads to Supports (Ibs) Accessories Dead Floor Live Total 1 - Trimmer - HF 3.00" 3.00" F 1.50" 267 490 757 None 2 - Trimmer - HF 3.00" 3.00" 1 1.50" 267 490 757 None Lateral Bracing Bracing Intervals comments Top Edge (Lu) 3' 6" o/c Bottom Edge (Lu) 3' 6" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 0 to 3' 6" N/A 5.5 -- 1 - Uniform (PSF) 0 to 3' 6" 7' 21.0 40.0 floor System: Wall Member Type : Header Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 17 / 18 aFORTE'CM Third Floor, deck rim beam 1 piece(s) 6 x 10 DF No.2 PASSED f All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1451 @ 3 1/2" 5156 (1.50") Passed (28%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 1274 @ 1' 1" 5922 Passed (22%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 4716 @ 6' 9 1/2" 6032 Passed (78%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.226 @ 6' 9 1/2" 0.433 Passed (L/689) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.281 @ 6' 9 1/2" 0.650 Passed (L/556) 1.0 D + 1.0 L (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. • Applicable calculations are based on NDS. Supports or Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Total 1 - Hanger on 9 1/2" DF beam 3.50" Hanger- 1.50" 290 1223 1513 See note 2 - Hanger on 9 1/2" DF beam 3.50" Hanger- 1.50" 290 1223 1513 See note ' • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 13' o/c Bottom Edge (Lu) 13' o/c -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Drop Beam Building Use : Residential Building Code : IBC 2018 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 1 - Face Mount Hanger HU68 2.50" N/A 10-16d 4-16d 2 - Face Mount Hanger HU68 2.50" N/A 10-16d 4-16d • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Comments 0 - Self Weight (PLF) 3 1/2" to 13' 3 1/2" N/A 13.2 1 - Uniform (PSF) 0 to 13' 7" (Front) 3' 10.0 60.0 deck Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by Built Engineering, PLLC ForteWEB Software Operator Job Notes Brice Parrish Built Engineering (253) 985-5008 briceparrish@gmaii.com 11/29/2021 10:43:16 PM UTC ForteWEB v3.2, Engine: V8.2.0.17, Data: V8.1.0.16 Weyerhaeuser File Name: Pine Park Bldg A Page 18 / 18 MPP ASD Reference Design Values Major Strength Direction I Minor Strength Direction F16-2 2 37 6.2 1,110 16 0.82 2,190 210 2.8 0.17 695 F16-3 3 37 9.3 1,870 51 1.23 2,190 355 9 0.26 695 F16-4 4 37 12.3 3,325 122 1.64 2,925 630 21 0.34 930 F16-5 5 37 15.4 5,200 238 2.05 3,650 985 42 0.43 1,160 F16-6 6 37 18.5 7,500 410 2.46 4,375 1,420 72 0.69 1,390 F16 F16-7 7 37 21.6 10,200 652 2.66 5,100 1,930 114 0.81 1,630 F16-8 8 37 24.7 13,325 973 3.04 5,825 2,525 170 0.91 1,860 F16-9 9 37 27. 16,850 1,385 3.42 6,575 3,200 242 1.04 2,090 F16-10 10 37 30.8 20,825 1,900 3.8 7,300 3,950 333 1.15 2,320 F16-11 MMJLM� 37 33.9 25,175 2,529 4.18 8,025 4,775 443 J==JJ6m 2,550 F16-12 12 37 37.0 29,975 3,283 4.56 8,750 5,675 575 1.38 2,775 SIMPLE SPAN DESIGN - 6"MPP PANEL L (ft) 19.5 W (plf) 61 W (live, plf) 40 El 4.10E+08 V 0.59475 M 2.89941 Vr 4.3 k Mr 7.5 k-ft defl (total) 0.48 L/ 483 690.6386 defl (live) 0.32 L/ 737 USE 6" F16 MPP PANEL BLDG A BALCONY POST/CONNECTION r- L LA 6, hlI BLDG A POST IN WALL AT BALCONY Shape: 5.25X7FS Material: PSL Length: 8 ft I Joint: N2 J Joint: N4 Envelope Code Check: 0.587 (LC 3) Report Based On 97 Sections A f(y) fa 633 at 0 ft -1.898 at 6 ft 1.393 at 6 ft -1.393 at 6 ft 017at0ft -.052 at 6 ft AWC NDS-18: ASD Code Check Max Bending Check 0.587 (LC 3) Location 6 ft Equation 3.9-1 CD 1 RB 4.938 Cr 1 Cfu 1 Fc' Ft' Fb' Fv' E' (ksi) Cm Ct PROVIDE (2) STEEL ANGLES W/ (4) 1/4x3-1/2 SIDS SCREWS EACH SIDE OF POST, AND (4) EACH ANGLE TO FLOOR, CAP=2.4K Max Shear Check 0.331 (LC 3) Location 6 ft Max Defl Ratio L/3831 CL .997 CV 1 CP .734 CF In Out 1.834 1 1 1 1.75 1 1 1 2.5 1 1 1 .23 1 1 1800 1 1 Lb 8 ft 8 ft le/d 18.28613.714 Sway No No Le -Bending Top 8 ft Le -Bending Bot 8 ft -1 k-ft BEARING AND SHEAR CHECK OF 6" PILE CAP SHEAR AREA=140 inA2, W= 1620 dead,1600 live, 500 snow. Wu=4.7 k/ft. Vu = 11.8k each side of pile cap. phiVc= 11.9k. OK. Considering a 10" wide rectangular beam with d=15" and (2) #4 bars, phiMn=38.2 k-ft. Considering simply supported span @ 5'-0" Mu=14.7 k-ft. moment is okay. Bearing area = 36 in12. 4.7*5=23.5k/36=652 psi <.85fc ok