Loading...
APVD BLD RESUB1 BLD2024-1278+Architectural_Plan+11.5.2024_10.11.58_AM+4602015Alterations Worksheet - 2018 Washington State Energy Code Project Information Contact Information v192nd Q s v The WSEC requirements for alterations are located in Chapter 5 of the code text t to Alterations (remodels) do not need to obtain energy credits from Table R406.3 Qom. Additions must meet the requirements for new construction. This includes noncondit►oned space bei �r 'Q'�`� altered to become conditioned space. n • O 00 00 z s, Q 3 Will the wall cavities be exposed? Yes X No Q1 D If yes: Exposed wall cavities must be insulated - > s �Q� ,? ;, rD 2 X 4 wall studs require R-15 Insulation per` O O 2 X 6 wall studs require R-21 insulation 1116 Excelsior PI Dr. Q J�e� Will the roof/ceiling framing cavities or attic be exposed? Yes X No �r Puget Dr. 196th St. SW If yes: Exposed roof/ceiling assemblies must be Insulated - Ny. Vaulted ceilings: Insulate to the full depth of the framing member while allowing for the minimum 1" ventilated spat. Flat ceilings Install R49 Insulation or what the attic space can 00 accommodate based on the roof pitch iD 00 Vieland W W y• s D WIII the floor framing cavities be exposed? Yes XNo D �D rfl z If yes: Exposed floor cavities must be insulated to R-30 Are the windows and/or doors being replaced? Yes X No -it ]wr a'lt7 frarrvs, If yes: Ne�,-v windows and doors must have an area weighted average U-factor of s0.3C Will the heating or cooling system be replaced? r Yes IK No If yes: New equipment must meet current requirements and ducts need to be tested WIII the hot water system be altered? " Yes X No If yes: New water heating equipment must meet current code requirements Are more than 50 of the light fixtures being changed? Yes X No If yes: 90 of all lamps must be high efficacy (LED or CFL) 1 Window. Skylight and Door Schedule Rai. U-fac:r Exempt Swinging Door (24 sq. tt. max ) Exempt Glazed Fenestration (15 sq. ft. max.) wrtical F•rwstratiion (Windows and doors) Component uescriprion me, u-race Sunrloom/Dedr VkM Slider 1 10.30 F Overhead Glazing (Skylights) Component • ram. ! : •,!.,• •�.: Wldtn Heighl Ot Feet Feet Area UA 0.0 0 00 0.0 0 00 Width Heigr: n* FAP1 FAPt IDO®MMS GEMEME IGE©MSEE =MEMO =MEMO IEIM■M■ EIMEMO -MEMO =MEMO =MEMO =MEMO IMM■M■ =MEMO -_■-■ Sum of Vertical fenestration Area and UA Vertical Fenestration Area Weighted U = UAIArea Ket u-ractor 0.50 Width Height O! Feet bxh Feet Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UAIArea Total Sum of Fenestration Area and UA (for heating system sizing calculations) Area 11A 1 1 11 1 1 • 11 1 1 11 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 Area UA 11 11 111 11 111 11 111 11 111 11 111 4.01 200 0501 94.0 29 00 ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 1 SPECIAL INSPECTIONS ARE REQUIRED FOR THE FOLLOWING: 1 � Reinforced Concrete Observation by j 1 Spray applied Fireproofing design professional 1 Bolting in Concrete Structural Masonry 1 Smoke Control Systems Vol Grading/soils j Prestressed Concrete Structural Steel/Welding j 1 Lateral Wood Retaining Wall Block Installation 1 Shotcrete High Strength Bolting Retaining Wall Footings 1 1 HARDWARE & FASTENERS IN CONTACT WITH PRESERVATIVE -TREATED 1 1 WOOD SHALL BE OF HOT -DIPPED ZINC GALVANIZED STEEL, STAINLESS j STEEL, SILICON BRONZE OR COPPER. IN THE ABSENCE OF 1 MANUFACTURER'S RECOMMENDATIONS A MINIMUM OF ASTM A 653 TYPE j G185 ZINC -COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. 1 IRC R317.3.1 IBC 2304.10.5.1 1 _.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._..a INSTALL PER MANUFACTURERS SPECIFICATIONS. HAVE ALL MANUFACTURER DOCUMENTATION ON SITE. 1 I LOT LINE STAKES MUST BE IN PLACE AT TIME OF FOUNDATION INSPECTION APPROVED PLANS MUST BE ON JOB SITE City Of Edmonds Building Department Work SUNROOM Address 1116 EXCELSIOR PL Owner ------------------ CANTWELL ------------------------- Approved Date /08/2024 Building Official ---------------- Permit Number ---------- BLD2024-1278 Olympic Ave. K VICINITY TABLE OF. CONTENTS. COVER SHEET: Pi VICINITY MAP, PROJECT INFO., P2 PLOT PLAN ARCHITECTURAL: Al ELEVATIONS A2 EX. BASEMENT PLAN A3 EX. 1ST FLOOR A4 EX. 2ND PLAN STRUCTURAL DRAWINGS: S1.1-6.1 STRUCTURAL PLAN PROTECT INF 200th St. SW 1. LEGAL DESCRIPTION: EDMONDS SEA VIEW TRACTS BLK 000 D-02- E1 /2 TR 91 & 92 LESS W 70FT THOF 2. PARCEL NUMBER 004346000009102 3. VICINITY MAP (SEE THIS PAGE). 4. REMODEL: 1116 EXCELSIOR ST. EDMONDS, WA. 98020 5. OWNER: RICHARD AND DIANE CANTWELL 6. STRUCTURAL ENGINEER: C G ENGINEERING. BEN JAMES BENJ@CGENGINEERING.COM 7. BASEMENT = EX. LIV: 1,191.58 SQ. FT., EX. COVERED PATIO 255.00 SQ.FT. 8. 1ST FLOOR = EX. LIV: 1,076.58 SQ. FT., EX. EX. COVERED PATIO 88.00 SQ.FT., EX. UNCOVERED DECK 156.73 SQ. FT. PROPOSED EXISTING DECK TO BE COVERED 156.73 SQ. FT. 9. 2ND = EX. LIV: 651.59 SQ. FT., EX. 10. WIND EXPOSURE B, SEISMIC ZONE D, SOIL: 2000PSF. 11.00CUPANCY: GROUP R, DIVISION 3. 12. THIS BUILDING IS TYPE VB. 13. GLAZING U VALUE VERTICAL = .30U VALUE OR BETTER, OVERHEAD U VALUE =.50, CEILING R VALUE=R-49, WALL R VALUE=21, FLOOR INSUATION R-30, SLAB R VALUE=R-10 14. COMPLY WITH IBC 2021', IRC 2021', IMC 2021', IFC 2021', UPC 2021, WSEC 2021. 15. ADDRESS NUMBERS (6" HEIGHT ON APPR. CONTRASTING BACKGROUND) SHALL BE POSTED PLAINLY VISIBLE & LEGIBLE FROM STREET OR ROAD FRONTING PROPERTY. 16. PROVIDE FIRE ESTINGUISHERS PER IFC STANDARD 10-1. LU Z .. � Z_ J 11. w n � O =� U W w N .. -1 CZ o< H U w� Xz O wo w 10.21.24 REVISIONS: RESUB Nov 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES PRINTED: 10.21.24 EXCELSIOR STREET PUDGET DRIVE LEGAL DESCRIPTION: EDMONDS SEA VIEW TRACTS BLK 000 D-02-E1/2 TR 91 & 92 LESS W/ 7oFT THOF PARCEL NUMBER: 004346o00009102 LOT AREA: 2240.00 SQ. FT. LOT COVERAGE: EX. HOUSE: 1516.00 SQ. FT EX. GARAGE: 768.00 SQ. FT. EX. STUDIO: 444.00 SQ. FT. TOTAL: 2,728.00 SQ. FT./ 22240.00 SQ FT. (LOT SIZE) = 12% HEIGHT LIMIT: 25' EX HEIGHT CALCULATIONS: A. 99.00' B. 99.00' C. 1o6.00' D. 103.25' /4 = AVERAGE GRADE = 101.56' EX. ACTUAL HEIGHT: 126.56' MAX HEIGHT: 151.56' IMPERVIOUS SURFACE CALCULATON: (NO CHANGE) N PLOT PLAN. SCALE: 1" = 20'-0" SCALE: 1/4" =1'-o" �F%! 1 -44wt � �r �r ��mmw1r Mow 1�r 1ML-1mvt1• SCALE: 1/4" =1'-o" SCALE: 1/4" =1'-o" ROOF PITCH: 12/12 MAIN KOOF 3/12 5HED OVERHANGS: SEE FLAN K K EX. BASEMENT FLOOR PLAN SYMBOL5 _ EX.(EXT TYPE) o EX. INDICATE5 2X4 @ 16" O.C. P05T U.N.O. 0 120V 5 M K DET W/BATT BACKUP CARBON MONOXIDE DETECTOR PER IRC 315 22"00" ATTIC ACCE55 (30" MIN. VERT. CLEAR. WEATHER5TRIP & IN5UL. TO R-49 PER W5EC 502.1.4.4 • CFM FAN COMPLY WITH M1507, 2018 IRC SCALE:1/4" =1'-O" EX. LIVING: 1,191.58 SQ. FT. EX. COVERED PATIO: 255.00 SQ. FT SYMBOLS _ EX.(EXT TYPE) o EX. INDICATE5 2X4 @ 16" O.C. P05T U.N.O. 0 120V 5 M K DET W/BATT BACKUP CARBON MONOXIDE DETECTOR PER IRC 315 22"00" ATTIC ACCE55 (30" MIN. VERT. CLEAR. WEATHER5TRIP & IN5UL. TO R-49 PER W5EC 502.1.4.4 • CFM FAN COMPLY WITH M1507, 2018 IRC SCALE:1/4" =1'-0" EX. LIVING: 1,076.58 SQ. FT. EX. UNCOVERED DECK 156.73 SQ. FT. EX. COVERED DECK: 88.00 SQ. FT. PROPOSED EXTERIOR COVERED DECK/SUNROOM: 156.73 SQ. FT (EXISTING UNCOVERED DECK TO BE COVERED) SYMBOL5 _ EX.(EXT TYPE) o EX. INDICATE5 2X4 @ 16" O.C. P05T U.N.O. 0 120V 5 M K DET W/BATT BACKUP CARBON MONOXIDE DETECTOR PER IRC 315 22"00" ATTIC ACCE55 (30" MIN. VERT. CLEAR. WEATHER5TRIP & IN5UL. TO R-49 PER W5EC 502.1.4.4 • CFM FAN COMPLY WITH M1507, 2018 IRC SCALE: 1/4" =1'-0" EX. LIVING: 651.59 5Q. FT. NO CHAGE TO FLOOR PLAN