REVIEWED BLD2024-0330+Energy_Calculations+3.9.2024_9.48.29_PM+4116163RECEIVED BLD2024-0330 RMar142024 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family — New & Additions (effective February 1, 2021) .............................................. REVIEWED BY CITY OF EDMONDS i Version 1.0 BUILDING DEPARTMENT; These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information Bruce & Martha Scholten/Youn -Scholten residential Phillip Lehn Architect - 16202 72nd Ave W - Edmonds, W addition - 2116 90th Ave W - Edmonds, WA 98026 98026 - 425-745- 8949 - plehn_lehndesiqn.com Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits Authorized Representative Phillip Lehn Architect Date March 9, 2024 All Climate Zones (Table R402.1.1) R-Valuea U-Factora Fenestration U-Factor b n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC b,e n/a n/a Ceiling e 49 0.026 Wood Frame Wall g,h 21 int 0.056 Floor 30 0.029 Below Grade Wall `,h 10/15/21 int + TB 0.042 Slab d,f R-Value & Depth 10, 2 ft n/a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. The fenestration U-factor column excludes skylights. b "10/15/21 +5TB11 means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for g climate zone 5 of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. 89 49 Prescriptive Path —Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R406.2 Heating Options Fuel Normalization Descriptions Credits - select ONE heating option User Notes 1 Combustion heating minimum NAECAb 0.0 ❑ 2 Heat pump` 1.0 ❑ 3 Electric resistance heat only - furnace or zonal -1.0 ❑ 4 DHP with zonal electric resistance per option 3.4 0.5 ❑ 5 All other heating systems -1.0 Credits - select energy option category ❑ Energy Options p Energy Credit Option Descriptions ONE from each 1.1 Efficient Building Envelope 0.5 ❑ 1.2 Efficient Building Envelope 1.0 ❑ 1.3 Efficient Building Envelope 0.5 ❑ 1.4 Efficient Building Envelope 1.0 ❑ 1.5 Efficient Building Envelope 2.0 ❑ 1.6 Efficient Building Envelope 3.0 ❑ 1.7 Efficient Building Envelope El 0.5 ❑ 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ 2.4 Air Leakage Control and Efficient Ventilation Li 2.0 ❑ 3. la High Efficiency HVAC 1.0 ❑ 3.2 High Efficiency HVAC 1.0 ❑ 3.3a High Efficiency HVAC 1.5 ❑ 3.4 High Efficiency HVAC 1.5 ❑ 3.5 High Efficiency HVAC 1.5 ❑ 3.6a High Efficiency HVAC 2.0 ❑ 4.1 High Efficiency HVAC Distribution System 0.5 ❑ 4.2 High Efficiency HVAC Distribution System 1.0 ❑ Prescriptive Path -Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family — New & Additions (effective February 1, 2021) — Summary of Table Energy Credit Option Descriptions (cont.) Efficient Water Heating Efficient Water Heating Efficient Water Heating R406.2 (cont.) Energy Options Credits - select ONE energy option from each category d 5.1d 0.5 ❑ 5.2 0.5 ❑ 5.3 1.0 ❑ 5.4 Efficient Water Heating 1.5 ❑ 5.5 Efficient Water Heating 2.0 ❑ 5.6 Efficient Water Heating 2.5 ❑ 6.1e Renewable Electric Energy (3 credits max) 1.0 ❑ 7.1 Appliance Packaee 0.5 ❑ User Notes Total Credits I I 3 IlCalculate Totall I Gear Form a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c. Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options 5.2 through 5.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation provided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 through 3 of this worksheet for submission to your building official. Prescriptive Path —Single Family 2018 Washington State Energy Code-R 3 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family— New & Additions (effective February 1, 2021) Table 406.3 — Energy Credits (Single Family) Option Description Credits: SF 1. EFFICIENT BUILDING ENVELOPE OPTIONS Only one option from Items 1.1 through 1.7 may be selected in this category. Compliance with the conductive UA targets is demonstrated using Section R402.1.4, Total UA alternative, where [1- (Proposed UA/Target UA)] > the required %UA reduction. Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.1 Vertical fenestration U = 0.24 0.5 1.2 Prescriptive compliance is based on Table R402.1.1 with the following modifications: 1.0 Vertical fenestration U = 0.20 Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.28 Floor R-38 1.3 Slab on grade R-10 perimeter and under entire slab below grade slab R-10 perimeter and 0.5 under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.25 Wall R-21 plus R-4 ci Floor R-38 1.4 Basement wall R-21 int plus R-5 ci 1.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 15% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.22 Ceiling and single -rafter orjoist-vaulted R-49 advanced Wood frame wall R-21 int plus R-12 ci Floor R-38 1.5 Basement wall R-21 int plus R-12 ci 2.0 Slab on grade R-10 perimeter and under entire slab Below grade slab R-10 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 30% Prescriptive compliance is based on Table R402.1.1 with the following modifications: Vertical fenestration U = 0.18 Ceiling and single -rafter orjoist-vaulted R-60 advanced Wood frame wall R-21 int plus R-16 ci 1.6 Floor R-48 3.0 Basement wall R-21 int plus R-16 ci Slab on grade R-20 perimeter and under entire slab Below grade slab R-20 perimeter and under entire slab or Compliance based on Section R402.1.4: Reduce the Total conductive UA by 40%. Advanced framing and raised heel trusses or rafters Vertical Glazing U-0.28 1.7 R-49 Advanced (U-0.020) as listed in Section A102.2.1, Ceilings below a vented attic and 0.5 R-49 vaulted ceilings with full height of uncompressed insulation extending over the wall top plate at the eaves. Prescriptive Path — Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family— New & Additions (effective February 1, 2021) Table 406.3 — Energy Credits (Single Family) Option Description Ai&Credits: SF 2. AIR LEAKAGE CONTROL AND EFFICIENT VENTILATION OPTIONS Only one option from Items 2.1 through 2.4 may be selected in this category. Compliance based on R402.4.1.2: Reduce the tested air leakage to 3.0 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.3 cfm/sf maximum at 50 Pascals and All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall 2.1 be met with a high efficiency fan(s) (maximum 0.35 watts/cfm), not interlocked with the 0.5 furnace fan (if present). Ventilation systems using a furnace including an ECM motor are allowed, provided that they are controlled to operate at low speed in ventilation only mode. To qualify to claim this credit, the building permit drawings shall specify the option being selected and the maximum tested building air leakage, and shall show the qualifying ventilation system and its control sequence of operation. Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 2.0 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.2 air leakage to 0.25 cfm/sf maximum at 50 Pascals and 1.0 All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.65. 1 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 1.5 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.3 air leakage to 0.25 cfm/sf maximum at 50 Pascals and 1.5 All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.75. 1 Compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested 2.4 air leakage to 0.15 cfm/sf maximum at 50 Pascals and 2.0 All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilation system with minimum sensible heat recovery efficiency of 0.80. Duct installation shall comply with Section R403.3.7. 1 qualify to claim this credit, the building permit drawings shall specify the option being selected and shall ecify the maximum tested building air leakage and shall show the heat recovery ventilation system. Irpo Prescriptive Path — Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family — New & Additions (effective February 1, 2021) Table 406.3 — Energy Credits (Single Family) Option Description Credits: SF 3. HIGH EFFICIENCY HVAC EQUIPMENT OPTIONS Only one option from Items 3.1 through 3.6 may be selected in this category. 2 Energy Star rated (U.S. North) Gas or propane furnace with minimum AFUE of 95% or 3.1 1.0 Energy Star rated (U.S. North) Gas or propane boiler with minimum AFUE of 90%. 2 3.2 2 Air -source centrally ducted heat pump with minimum HSPF of 9.5. 3 1.0 Closed -loop ground source heat pump; with a minimum COP of 3.3 or 3.32 Open loop water source heat pump with a maximum pumping hydraulic head of 150 feet 1.5 and minimum COP of 3.6. 3 Ductless mini -split heat pump system, zonal control: In homes where the primary space 3.4 heating system is zonal electric heating, a ductless mini -split heat pump system with a 1.5 minimum HSPF of 10.0 shall be installed and provide heating to the largest zone of the housing unit. 4 3.5 2 Air -source, centrally ducted heat pump with minimum HSPF of 11.0. 4 1.5 Ductless split system heat pumps with no electric resistance heating in the primary living areas. A ductless heat pump system with a minimum HSPF of 10 shall be sized and installed to provide heat to entire dwelling unit at the design outdoor air temperature. 3.61 2.0 To qualify to claim this credit, the building permit drawings shall specify the option being selected, the heated floor area calculation, the heating equipment type(s), the minimum equipment efficiency, and total installed heat capacity (by equipment type). n alternative heating source sized at a maximum of 0.5 W/sf(equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit. s To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and the minimum equipment efficiency. 4. HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM OPTIONS All supply and return ducts located in an unconditioned attic shall be deeply buried in ceiling insulation in accordance with Section R403.3.7. For mechanical equipment located outside the conditioned space, a maximum of 10 linear feet of return duct and 5 linear feet of supply duct connections to the equipment may be 4.1 outside the deeply buried insulation. All metallic ducts located outside the conditioned 0.5 space must have both transverse and longitudinal joints sealed with mastic. If flex ducts are used, they cannot contain splices. Duct leakage shall be limited to 3 cfm per 100 square feet of conditioned floor area. Air handler(s) shall be located within the conditioned space. HVAC equipment and associated duct system(s) installation shall comply with the requirements of Section R403.3.7. Locating system components in conditioned crawl spaces is not permitted under this option. 4.2 Electric resistance heat and ductless heat pumps are not permitted under this option. 1.0 Direct combustion heating equipment with AFUE less than 80% is not permitted under this option. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the heating equipment type and shall show the location of the heating and cooling equipment and all the ductwork. Prescriptive Path — Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family— New & Additions (effective February 1, 2021) Table 406.3 — Energy Credits (Single Family) Option Description Credits: SF S. EFFICIENT WATER HEATING OPTIONS Only one option from Items 5.2 through 5.6 may be selected in this category. Item 5.1 may be combined with any option. A drain water heat recovery unit(s) shall be installed, which captures waste water heat from all and only the showers, and has a minimum efficiency of 40% if installed for equal flow or a minimum efficiency of 54% if installed for unequal flow. Such units shall be rated in accordance with CSA B55.1 or IAPMO IGC 346-2017 and be so labeled. 5.1 0.5 To qualify to claim this credit, the building permit drawings shall include a plumbing diagram that specifies the drain water heat recovery units and the plumbing layout needed to install it. Labels or other documentation shall be provided that demonstrates that the unit complies with the standard. 5.2 Water heating system shall include one of the following: 0.5 Energy Star rated gas or propane water heater with a minimum UEF of 0.80. S Water heating system shall include one of the following: Energy Star rated gas or propane water heater with a minimum UEF of 0.91 or Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation (SRCC) Annual Performance of OG-300 Certified Solar Water Heating 5.3 Systems or 1.0 Water heater heated by ground source heat pump meeting requirements of Option 3.3. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall specify the water heater equipment type and the minimum equipment efficiency and, for solar water heating systems, the calculation of minimum energy savings. Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier I of NEEA's advanced water heating specification or 5.4 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier I of 1.5 NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. S Water heating system shall include one of the following: Electric heat pump water heater meeting the standards for Tier III of NEEA's advanced water heating specification or 5.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of 2.0 NEEA's advanced water heating specification, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. S Water heating system shall include one of the following: Electric heat pump water heater with a minimum UEF of 2.9 and utilizing a split system configuration with the air -to -refrigerant heat exchanger located outdoors. Equipment shall meet Section 4, requirements for all units, of the NEEA standard Advanced Water Heating Specification with the UEF noted above or 5.6 2.5 For R-2 Occupancy, electric heat pump water heater(s), meeting the standards for Tier III of NEEA's advanced water heating specification and utilizing a split system configuration with the air -to -refrigerant heat exchanger located outdoors, shall supply domestic hot water to all units. If one water heater is serving more than one dwelling unit, all hot water supply and recirculation piping shall be insulated with R-8 minimum pipe insulation. S shall 5 To qualify to claim this credit, the building permit drawings shall specify the option being selected and specify the water heater equipment type and the minimum equipment efficiency. Prescriptive Path — Single Family 2018 Washington State Energy Code-R 2018 Washington State Energy Code — Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family— New & Additions (effective February 1, 2021) Table 406.3 — Energy Credits (Single Family) Description 6. RENEWABLE ELECTRIC ENERGY OPTION 6.1 For each 1200 kWh of electrical generation per housing unit provided annually by on -site wind or solar equipment a 1.0 credit shall be allowed, up to 3 credits. Generation shall be calculated as follows: For solar electric systems, the design shall be demonstrated to meet this requirement using the National Renewable Energy Laboratory calculator PVWATTs or approved alternate by the code official. Documentation noting solar access shall be included on the plans. For wind generation projects designs shall document annual power generation based on the following factors: the wind turbine power curve; average annual wind speed at the site; frequency distribution of the wind speed at the site and height of the tower. To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall show the photovoltaic or wind turbine equipment type, provide documentation of solar and wind access, and include a calculation of the minimum annual energy power uction. 7. APPLIANCE PACKAGE OPTION 7.1 All of the following appliances shall be new and installed in the dwelling unit and shall meet the following standards: Dishwasher — Energy Star rated Refrigerator (if provided) — Energy Star rated Washing machine — Energy Star rated Dryer— Energy Star rated, ventless dryer with minimum CEF rating of 5.2 To qualify to claim this credit, the building permit drawings shall specify the option being selected and shall show the appliance type and provide documentation of Energy Star compliance. At the time of inspection, all appliances shall be installed and connected to utilities. Dryer ducts and exterior dryer vent caps are not permitted to be installed in the dwelling unit. Credits: SF 1.0 [$IV Prescriptive Path — Single Family 2018 Washington State Energy Code-R Property address: 2116 90th Ave W - Edmonds, WA 98026 Builder/registered design professional name: Phillip Lehn Architect Builder/reg. design pro. signature: Phillip Lehn Conditioned floor area: 1,443 ftZ (per building permit) R-Values R303.1.1 Ceiling/ Vaulted R-4g_ Floors: Over unconditioned space R- 30 Attic: Attic R- Slab -on -grade floor R- Walls: Above grade R- 21 Fully insulated slab? Y/N (Circle one) Below, int. R- Doors: R- R- , R- Below, ext. R- U-Value of Windows, Skylights and Doors (R303.1.1.3) Average area weighted U-value from Glazing Worksheet 0.265 Fuel Normalization Tables R406.2 and Energy Credits Table R406.3 System Type Number (1 to 5) (Select one) Energy Credits selected (1 to 7) 6.1 = 3 MAX Fuel Normalization Credit + Total Energy Credits 3 = Total Credits—3. Heating, Cooling and Domestic Hot Water System Type Manufacturer and Model Number Efficient Heating Owners are undecided and are waiting for general Cooling contractors' prices to know what they can afford and want to buy. ' DHW Drain water heat recovery Onsite Renewable Energy Electric Power System System type SOLAR PHOTOVOLTAICS System design capacity 10.66 kW Rated annual generation 84 % ENERGY OFFSET kWh/vr Appliances Energy Star? Manufacturer and Model (Circle one) Dish washer Owners are reusing the house's existing appliances N Refrigerator N Washer N N Dryer Vented or unvented? If vented, CEF rating Gas fireplace / heating stove (Section R402.4.2) Fireplace efficiency (FE) ? Decorative (Circle one) HVAC System Duct Leakage Testing (R403.3) Circle one All ductwork and air handler in conditioned space? (See Option 4.2) N All ductwork in unconditioned spaces buried and tested at 3% total leakage, and air N handler in conditioned space? (See Option 4.1.) All ductwork & air handler outside conditioned space insulated to minimum R-8? Y Air handler present at duct leakage test? (Total leakage 4% if yes, 3% if no) Y or N HVAC leakage to outside test conducted at final? Y or N Do HVAC duct leakage tests include GPS and time stamp verification? Y or N HVAC system leakage test calculated design target: CFM @ 25 Pa HVAC system leakage test measured results: CFM @ 25 Pa Building Leakage Testing (R402.4.1.2) Dwelling unit leakage test calculated design target: ACH @ 50 Pa Dwelling unit leakage test, measured results: ACH @ 50 Pa Whole Building Leakage test (R2 corridor only) design target: CFM/sf @ 50 Pa Whole Building Leakage test (R2 corridor only) measured: CFM/sf @ 50 Pa Do building leakage tests include GPS and time stamp verification? Y or N Whole House Ventilation System Measured Flow Rates (M1505.4 /RC -WA) Circle one Are the system controls correctly labeled? Y or N The Whole House Ventilation (WHV) system operation and maintenance (O&M) Y or N instructions were provided to the building owner? Provided to: on (date) Whole House Ventilation System Type: (Circle one) (1) Whole house exhaust fan, location KITCHEN (2) Balanced HRV/ ERV, location For R2 low-rise, serves more than one unit? Y or© (3) Supply or HRV WHV integral to the air handler. Describe system control sequence of operations or reference to design submittal: Specify run-time: _? hours per day WHV calculated design minimum flow rate per plan submittal: WHV measured min flow rate at commissioning: Exhaust 100 CFM, Supply 100 CFM Do WHV flow tests include GPS & time stamp verification? Y or N HRV/ERV sensible heat recovery efficiency: Commissioning Notes: Other Mandatory Requirements Circle one All other mandatory requirements of WSEC-R have been met? Energy Program Instructions - WASHINGDDNSTATEUNNERSI9Y 2018 WSEC-Residential Energy Compliance Certificate The Washington State Energy Code (WSEC) requires a Code Compliance Certificate be permanently posted in all new dwelling units, per Section R401.3, including individual apartment units. The Certificate shall be completed (typically prior to occupancy) by the "builder or other approved party and posted in the space where the furnace is located, a utility room, or an approved location inside the building." The Certificate also provides important documentation related to the operations and maintenance instructions as required in Section R303.3 Maintenance information. The Certificate helps the builder and other stakeholders to confirm compliance with many (but not all) of the key WSEC-R requirements. Authorities Having Jurisdictions (AHJ) can compare information on the Certificate with approved design documents and on -site information. It provides critical information for the building owner, such as insulation installation, duct air sealing and testing &/or envelope testing affidavits or other documentation, and forms available at www.energycode.energV.wsu.edu. As well, a Certificate may provide helpful information for obtaining financing and insurance. The WSEC 2018 Certificate has ten parts, discussed in the sections below: • Property and builder/design professional information • R-values of walls, ceilings/roof, and floor, etc. • Tested or default U-values of windows, skylights and doors • Fuel normalization and energy credits • Heating, cooling and domestic hot water manufacturer and model • Onsite renewable energy electric power systems and energy savings documentation • Appliance manufacturer and model (refrigeration, dishwasher and clothes dryer) • HVAC system duct leakage testing affidavit • Building leakage testing test results form • Whole house ventilation system commissioning information Forms and affidavits to provide documentation of the information on the Certificate are available at www.energVcode.energV.wsu.edu and through manufacturers of testing and insulation. Property and Builder/Design Professional Information Property address: 21416 90th Ave W - Edmonds, WA 98026 Builder/registered design professional name: Phillip Lehn Architect Verified by pdfFiller a3,as,zaz9 Builder/reg. design pro. signature: pti;ll �etin Conditioned floor area: 1,741 In this section, provide the following information: ft2 (per building permit) • Property address or other information associated with the permit, as determined by the AHJ • Builder's or registered design professional's name • Conditioned floor area of the permitted project The certificate shall be signed in the space provided by the builder or registered design professional completing it. Energy Program Instructions - WAsHING oNSTATEUNNEttsrn 2018 WSEC-Residential Energy Compliance Certificate R-Values (R303.1.1) In this section on R-values and the following section on U-values, the primary components of the dwelling unit's exterior shell (or "building envelope") and their insulation values are summarized. R-Values (R303.1.1) Ceiling/ Vaulted R- 49 Floors: Over unconditioned space R- 30 attic Attic R- Slab -on -grade floor R- Walls: Above grade R- 21 Fully insulated slab? Y/N (Circle one) Below, int. R- Doors: R- 2.56 R- R- Below, ext. R- Provide R-values of insulation installed in or on the ceiling or roof, walls (above -grade, below -grade interior, and below -grade exterior, as applicable), floors over unconditioned spaces and slab -on -grade foundations (as applicable), and doors. Where there is more than one value for a component, provide the R-value covering the largest area. In answering the question "Fully insulated slab?" for slab -on -grade foundations, circle Y (yes) if it is fully insulated or N (no) if it is insulated only at the perimeter. U-Values of Windows, Skylights and Doors (Section R301.1.3) Enter the area weighted U-value for windows, skylights and doors, as calculated using the Glazing Worksheet, available for download at: http://www.energy.wsu.edu/BuildingEfficiency/EnergyCode.aspx. U-Value of Windows, Skylights and Doors (R303.1.1.3) Average area weighted U-value from Glazing Worksheet Average U- 0.265 U-values for individual windows, skylights and doors entered in the Glazing Worksheet may be default values obtained from Appendix A of the WSEC or the NFRC rating of the installed units. NRFC ratings may be obtained from manufacturer's product information or from the NFRC's Certified Products Directory. World's Best .... Window Co. Series"2000" Casement ENERGY PERFORMANCE RATINGS U-Facts USA-P) Solar Heat Gam Coefficient 0,27 1 0.25 ADDITIONAL PERFORMANCE RATINGS Ywble Transmittance Air Leakage IU SA•P) 0.51 < 0.3 U..w�ewrltaW��w s qw4 wa..a..w IiOC �....an •cww..w1 ayPwl.tl N�1�+r w.r. CwA .& �.Y�ACM\ ��w b M.► 0'�r rw,ft oa 2 Energy Program Instructions - WASHINGMNSTATEUNNERSny 2018 WSEC-Residential Energy Compliance Certificate Fuel Normalization (Table R406.2) and Energy Credits (Table R406.3) Each dwelling unit shall include sufficient options from Table R406.3 to achieve a certain number of energy credits, which varies depending on the size and type of the dwelling unit. The fuel normalization credit, selected from Table R406.2, is an adjustment to account for the carbon emission differences between fuels. Fuel Normalization (Tables R406.2) and Energy Credits (Table R406.3) System Type Number (1 to 5) (Select One) Energy Credits selected (1 to 7) 6.1 Renewable Electric Energy Option Fuel Normalization Credit + Total Energy Credits 3 = Total Credits 3 Enter the primary heating system type number (1-5) from Table R406.2. List all the Energy Credit Options implemented by number (1-7) per Table R406.3. Add the fuel normalization credit and the total energy credits to obtain the total credits. Heating, Cooling and Domestic Hot Water Summarize the types and efficiencies of the heating, cooling and hot water systems in this section. Heating, Cooling and Domestic Hot Water System Type Make and Manufacturer Model Number Efficient Heating Owners are waiting until they know contractors' Cooling prices to decide which HVAC system to buy DHW Drain water heat recovery Specify the make and manufacturer's model numbers or system types and their efficiencies for the primary space heating, cooling and water heating equipment installed. If there is more than one unit, specify the system serving the largest area. To verify the equipment efficiency with the make and model number of the field -installed furnaces, heat pumps and water heaters, go to the AHRI website, select the Product Type (e.g. Residential Furnace), and search on the manufacturer and model number. Then click the link under "AHRI Certified Reference Number" to download the AHRI Certificate. If a drain water heat recovery unit is installed, refer to Option 5.1 in Table R406.3 for efficiency and other installation requirements. The Passive House Institute maintains a list of drain water heat recovery systems, including their efficiencies. Energy Program Instructions - WASHINGIDN$TATEUNWERSITY 2018 WSEC- Reside ntial Energy Compliance Certificate This water heater qualifies for Federal Energy Efficiency Tax Credit when placed in service between 1/1/2015 and 12/31/2020. Certificate of Product Ratings AHRI Certified Reference Number — Dale . 06-25-2020 Model Status . Active Brand Name — Model Number Rated as follows in accordance with Department of Energy (DOE) Water Heater test procedures as published in the latest edition of the Code of Federal Regulations. 10 CFR Part 430 and subject to verification of rating accuracy, by AHRI-sponsored, Independent. third parry testing. First Hour PH _ 67 Uniform Energy Factor 3.55 The following data Is for reference only and Is not certified by AHRI Energy Source Heat Pump with Tank Heater Type: Storage Usage Bin _ Medium Usage Nominal Capacity (gal) : 50 DOE Rated Storage Volume (gal): 45 Input (kW) : 5-0 Recovery Efficiency. (%) : 436 Heat Traps . No Quick Search Criteria AHM Certdi Reference Number hard Name Metlel NNmber E—wSoerce Heat Pump with Tank Healer Type Select Heater Type First HINa Rating (GPIO Min Maz Max GPM Min Matt lalaerm ENergy Factor Min Mak Conduct Advanced Search Residential Water Heaters A Status Name Name Saurte Type sage PaNng GPM nerdy Cepeaay arege yalume Humbert¢ Numbc, Number Bin (GPH) fedor (gal) (gal) Heat Medium — Acllve Pump Storage Vsage 6T 3.55 5u 45 vttly Tank Heat Medium Acllve Pump Storage Usage 67 3.55 50 45 xitlt Tank 4 Energy Program Instructions - WASHINGTONSTATE UNIVERSITY 2018 WSEC-Residential Energy p Com liance Certificate Onsite Renewable Energy Electric Power System Enter information about renewable energy electric power systems installed (option 6). Onsite Renewable Energy Electric Power System System type: solar photovoltaic panels System design capacity 10.66 kW Rated annual generation 84% energy offset /yr kWh/yr Specify the system type (e.g., wind or solar PV) and provide the system design capacity in kW. Also, enter the rated annual generation in kWh per year. For solar electric systems, confirm the rated annual generation and system capacity with the calculation submitted as part of the plan review using NREL's PV Watts solar calculator or an approved alternate. For guidance on determining the rated annual generation of wind systems, refer to Option 6.1 in Table R406.3. Appliances WSEC 2018 includes an Appliance Package Option (option 7) to earn energy credits. Appliances Manufacturer and Model Energy Star? (Circle one) Dish washer Owners will reused existing appliances Y or N Refrigerator Y or N Washer Y or N Dryer Vented or unvented? If vented, CEF rating Y or N Gas fireplace 1 heating stove (Section R402.4.2) Fireplace efficiency (FE) Heating or Decorative? (Circle one) Decorative Provide the manufacturer and model number of new appliances installed in the dwelling unit, and indicate whether each appliance is Energy Star rated by circling Y or N. If the Appliance Package Option 7 is selected, all appliances shall be Energy Star rated. To determine if the appliance is Energy Star, go to https://www.energVstar.gov/, click the appliance type and enter the model number in the search tool. For dryers, also indicate if the unit is vented or ventless by circling one. For ventless dryers, indicate the combined energy factor (CEF) rating in Ibs/kWh, which you can look up by model number on the Energy Star website. Enter the fireplace efficiency (FE) of gas fireplaces used as heating appliances. Refer to Section R402.4.2.1 for minimum FE required. Gas fireplaces are not permitted to have continuously burning pilot lights. Note: Fireplaces with on -demand, intermittent or interrupted ignition are not considered continuous. Circle Y (yes) or N (no) to indicate that this requirement is met. FE should be provided with the manufacturer's product listing. The Energy Trust of Oregon maintains a list of fireplaces with FE of 70% and above. Energy Program Instructions - WASHINGPDNSTATEUNNEpsny 2018 WSEC-Residential Energy Compliance Certificate HVAC System Duct Leakage Testing Thermal losses from ductwork are strongly dependent on where the ductwork and the air handler are located. If located within the conditioned spaces, air leaks and transmission losses from the air distribution system still serve to heat the dwelling unit. Leaky ducts located in unconditioned spaces can be one of the largest energy losses. HVAC System Duct Leakage Testing (R403.3) I Circle One All ductwork and air handler in conditioned space? (See Option 4.2) Y or N All ductwork in unconditioned spaces buried and tested at 3% total leakage, and Y or N air handler in conditioned space? (See Option 4.1.) All ductwork & aid handler outside conditioned space insulated to minimum R-8? Yar N Air handler present at duct leakage test? (Total leakage 4% if yes, 3% if no) Y or N HVAC leakage to outside test conducted at final? Y or N Do HVAC duct leakage tests include GPS and time stamp verification? Y or N HVAC system leakage test calculated design target: CFM @ 25 Pa HVAC system leakage test measured results: CFM @ 25 Pa Identify the locations of ductwork by circling Y (yes) or N (no) in response to the following questions: • Is all ductwork and air handler located in a conditioned space? • For all ductwork located in unconditioned spaces, is the ductwork buried in insulation and tested, and the air handler is located in a conditioned space? • Is all ductwork and the air handler located outside conditioned space insulated to R8? • Was the air handler present at duct leakage test? • Was a HVAC leakage -to -outside test conducted at final? • Do duct leakage tests include a GPS and time stamp verification? A date -stamped smart phone photo or air leakage testing software may be used to satisfy this requirement. Duct leakage testing determines how leaky the air distribution system is by pressurizing or depressurizing the ducts and air handler. In this section: • Enter the calculated design target leakage rate in CFM at 25 Pa. The design target HVAC system leakage test is 4 CFM per 100 square feet of conditioned floor area tested at 25 Pa, per Section R403.3.4. • Enter the measured HVAC leakage results from the blower door test in CFM @ 25 Pa. This value should be less than or equal to the target value. Building Leakage Testing In this section, results of building leakage testing are entered. Building leakage testing determines how leaky the dwelling unit is by depressurizing or pressurizing it with a device called a blower door. For R2 low-rise apartments, individual blower door tests are required only for garden -style apartments without corridors, per WSEC R402.4.1.2. For corridor buildings where results are performed for the whole building, enter the results of the whole building and add the note "whole building." M. Energy Program Instructions - WASHING7'UNSTATE UNIVERSITY 2018 WSEC-Residential Energy Compliance Certificate Building Leakage Testing (R402.4.1.2) Dwelling unit leakage test calculated design target: ACH 0, 50 Pa Dwelling unit leakage test. measured results: A C H C 50 Pa Whole Building Leakage test (R2 non -corridor only) design target: CFMIsf @ 50 Pa Whole Building Leakage test (R2 non corridor only) measured: CFMIsf C 50 Pa Do building leakage tests include GPS and time stamp verification? Y or N • Enter the design target envelope leakage test in CFM at 50 Pa. The target leakage rate is 5 ACH@50 Pa per Section R402.4.1.2, unless one of the options from 2.1 to 2.4 is implemented to achieve energy credits by reducing building air leakage. • Enter the measured envelope leakage results from the blower door test in CFM @ 50 Pa. This value should be less than or equal to the target value. • Circle Y to indicate the envelope leakage tests have GPS and time stamp verification or, if not, circle N. A date -stamped smart phone photo of the form or air leakage testing software may be used to satisfy this requirement. Whole House Ventilation System Enter data on ventilation fans and whole house ventilation, including results of flow testing of the whole house ventilation system. For R2 low-rise apartments, individual whole house ventilation system flow testing is required for each dwelling unit. No sampling of representative apartments is allowed. Please note on the certificate if a single heat recovery unit is serving more than one dwelling unit. WHV Labeling and 0&M Instructions Whole House Ventilation System Measured Flow Rates (M105.4 IRC-WA) I Circle one Are the system controls correctly labeled? Y or N The Whole House Ventilation (WHV) system operation and maintenance (O&M) Y or N instructions were provided to the building owner? Provided to: on (date) Indicate that the system controls are correctly labeled by circling Y or N. To be correctly labeled, each switch, timer or other control shall have a permanently attached label identifying the fan it controls. Document that O&M instructions were provided to the building owner by circling Y or N. Provide the name of the person the instructions were provided to and the date of delivery. This is critical to ensure the current building owners and occupants understand how to maintain and operate the ventilation system as designed and installed. 7 Energy Program WASHINGPON STATE UNIVERSITY WHV System Type and Location Instructions - 2018 WSEC-Residential Energy Compliance Certificate Whole House Ventilation System Measured Flow Rates (M1505.41RC-WA) I Circle One Are the system controls correctly labeled? Y or N The Whole House Ventilation (WHV) system operation and maintenance (O&M) Y or N instructions were provided to the building owner? Provided to: ___ on _(date) Whole House Ventilation System Type: (circle one) (1) Whole house exhaust fan, location (2) Balanced HRVI ERV, location For R2 low-rise, serves more than one unit? Y or N (3) Supply or HRV WHV integral to the air handler. Describe system control sequence of operations or reference to design submittal: Identify the type of WHV system by circling one of the 3 types listed. For the selected type, enter its location per Table R403.6.1 (i.e., HRV, ERV, or WHV ventilation exhaust system. (A WHV ventilation exhaust may also provide bathroom, kitchen or utility ventilation requirements.) Balanced HRV and ERV systems will have both supply and exhaust fans and require that both airflows be documented. Please note any commissioning issues in the Commissioning Notes area. If the system is integral to the air handler, describe the system's control sequence of operation (SOO), or refer to design documents that provide the sequence of operation. The builder and/or the AHJ agent may want to verify SOO system performance as installed. WHV Run Time and Airflow Specify run-time: hours per day 100 CFM WHV calculated design minimum flow rate per plan submittal: WHV measured min flow rate at commissioning: Exhaust CFM, Supply CFM Do WHV flow tests include GPS & time stamp verification? Y or N Specify the run time in hours per day. If the system runs continuously, enter a run-time of 24 hours per day. Continuous operating systems require lower target design flow rates. Enter the calculated design minimum flow rate. To determine the target value, refer to Section M1505.4 Whole -house mechanical ventilation system of the Washington State Amendments of the 2018 International Residential Code for single family residences and dwelling units. For R2 low-rise apartments, refer to Section 403.4 Group R whole house mechanical ventilation system of the Washington State Amendments of the 2018 International Mechanical Code. Enter the measured minimum flow rate at commissioning of supply and exhaust fans, as applicable. This value should be equal to or greater than the design minimum flow rate. For balanced ERV and HRV systems, the supply and exhaust flow rates should be within 10% of each other or 5cfm whichever is larger. While this is required in the code, it is often hard to get a repeatable test at 5cfm. Circle Y or N to indicate whether the WHV system tests include GPS and time stamp verification. A date - stamped smart phone photo or air leakage testing software may be used to satisfy this requirement. Energy Program Instructions - WASHINGMNSTATEUNNERsny 2018 WSEC- Reside ntial Energy Compliance Certificate WHV Sensible Heat Recover Efficiency HRVIERV sensible heat recovery efficiency NA For HRV and ERV systems, enter the maximum rated sensible heat recovery efficiency, which is available in the Heating Ventilation Institute's certified products directory. From the HVI directory, use the Adjusted Sensible Recovery Efficiency (ASRE) at a flow rate that is no less than the design flow rate. When the design flow rate is between two listed flow rates in the HVI directory, interpolation of the ASRE shall be permitted. As an example, suppose a specifier selects an Alpha Model X13 HRV with a design flow rate of 70 cfm, listed as following in the HVI Section 3 Directory: Product Category Brand Name HRVs Alpha HRVs Alpha HRVs Alpha HRVs Alpha Model Temp Mod °C °F Net Airflow (Us) Net Airflow (cfm) WATTS SIRE ASRE X13 HEATING' 0' 32' 30' 64' 40' 71 76 X13 HEATING' 0 ' 32 ' 45 ' 95 ' 51 ' 69 ' 72 X13 HEATING' 0 ' 32 ' 55, 117 ' 60 ' 67 ' 70 X13 HEATING '-25 '-13 ' 32 ' 68 ' 52 ' 63 ' 65 For this case, the specifier may claim an ASRE of 72 (the highest ASRE associated with the rated flow that is no less than the design flow rate of 70 cfm) when complying with the "sensible heat recovery efficiency" requirement of Washington State's IECC-R Table R406.3; or, the specifier may interpolate to determine the ASRE between the rated flows that are greater than and less than the design flow (i.e., 64 cfm and 95 cfm are less than and greater than 70 cfm, respectively). Interpolating results in an ASRE of 75 for this case. All Other Mandatory Requirements Other Mandatory Requirements Ckde One All other mandatory requirements of WSEC-R have been met? r N Other mandatory requirements not specifically addressed on the Certificate include: • R403.1 Controls • R403.4 Mechanical Piping • R403.5 Service Hot Water Systems • R403.6 Mechanical Ventilation • R403.9 Snow Melt Systems • R403.1.0 Pool and Permanent Spa • R404 Lighting Equipment • R407 Certified Passive House (Need to provide PHIUS Project Certification 2018 or later)