Loading...
REVIEWED BLD2024-0330+Heat Pump Manufacturers Specifications+3.8.2024_7.02.21_PM+4115753Job Name: System Reference: Date: III RECEIVED oMar 14 20245 BLD2024-0330 ................................................ REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT? ..............................................: W FEATURES • Compatible with M- and P-Series and CITY MULTI indoor units. Branch box required for connection with M- and P-Series • Variable speed INVERTER -driven compressor • Seacoast protection on heat exchanger and base panel (rated for 2,000 hrs in accordance with ASTM B117 testing) • Thermal Differential 1 °F (with PAC-MKA32/52BC only) • Built-in base pan heater • Quiet outdoor unit operation, rated sound pressure as low as 49 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Hyper -heating performance offers 100% heating capacity at 5°F and 75% heating capacity at -13°F • ENERGY STAR° certified (non -ducted, mixed & ducted) ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix // Ducted) Maximum Capacity Rated Capacity BTU/H 36,000 // 36,000 // 36,000 BTU/H 36,000 // 36,000 // 36,000 Minimum Capacity Maximum Power Input BTU/H 15,500 // 15,500 // 15,500 W 2,400 // 2,610 // 2,855 Rated Power Input Power Factor (208V, 230V) W 2,400 H 2,610 112,855 % 98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 Heating at 47°F' (Non -Ducted H Mix H Ducted) Maximum Capacity Rated Capacity BTU/H 42,000 // 42,000 // 42,000 BTU/H 42,000 // 42,000 H 42,000 Minimum Capacity BTU/H 22,500 H 22,500 // 22,500 Maximum Power Input W 3,080 H 3,200 // 3,325 Rated Power Input W 3,080 H 3,200 // 3,325 Power Factor (208V, 230V) % 98.5, 98.5 H 98.5, 98.5 H 98.5, 98.5 Heating at 17°F3 (Non -Ducted // Mix // Ducted) Maximum Capacity BTU/H 42,000 // 42,000 H 42,000 Rated Capacity BTU/H 33,000 H 33,000 // 33,000 Maximum Power Input W 5,730 // 6,050 H 2,400 Rated Power Input W 3,450 H 3,600 // 3,750 Heating at 5°F4 (Non -Ducted H Mix H Ducted) Maximum Capacity BTU/H 42,000 // 42,000 H 42,000 Maximum Power Input W 6,155 // 6,315 H 6,480 Efficiency (Non -Ducted // Mix H Ducted) SEER 23.0 H 20.65 H 18.3 EER' 15.0 H 13.8 // 12.6 HSPF (IV) 12.5 H 12.1 H 11.7 COP at 47°F2 4.0 H 3.85 H 3.7 COP at 17°F at Maximum Capacity3 2.1 H 2.03 H 1.9 COP at 5°F at Maximum Capacity4 2.0 H 1.95 H 1.9 ENERGY STAR® Certified Yes H No H Yes Electrical Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size if Branch Box Powered by Outdoor Unit A 45 Recommended Fuse/Breaker Size without Branch Box or Branch Box Powered Separate A 40 Recommended Wire Size (Indoor - Outdoor) AWG 16 MCA if Branch Box Powered by Outdoor Unit A 42.0 MCA without Branch Box or Branch Box Powered Separate A 36 MOCP if Branch Box Powered by Outdoor Unit A 50 MOCP without Branch Box or Branch Box Powered Separate A 40 Fan Motor Full Load Amperage A 0.6+0.6 Fan Motor Output W 74 Outdoor unit Airflow Rate (Cooling / Heating) CFM 3,885 / 3,885 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level,Cooling' dB(A) 49 Sound Pressure Level,Heating2 dB(A) 53 Compressor Type Hermetic Compressor Model ANB33FJSMT Compressor Motor Output kW 2.8 Compressor Rated Load Amps A 19 Compressor Locked Rotor Amps A 22.0 Compressor Oil Type // Charge oz. FV50S H 73 Base Pan Heater Built-in Unit Dimensions W:In. [mm] 41-11/32[1,050] D: In. [mm] 13[330] H:In. [mm] 52-11/16[1,338] Package Dimensions W: In. [mm] 43 [1,090] D: In. [mm] 18 [450] H: In. [mm] 57 [1,430] Unit Weight Lbs.[kg] 278 [126] Package Weight Lbs.[kg] 302 [137] NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions ^Heating at 5°F (Indoor H Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. when 1 or more PLA-A-EA7 connected a Branch box should be placed within the level between the outdoor unit and indoor units ° 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum) °FDB 115 / 23 Cooling Thermal Lock -out / Re -start Temperatures °FDB N/A / N/A Heating Intake Air Temp (Maximum / Minimum) °FWB 59 / -13 Heating Thermal Lock -out / Re -start Temperatures °FDB -24 / -14 Refrigerant Type R410A Charge Lbs, oz 10, 9.0 Indoor unit connection Maximum Number of Connected IDU with Branch Box 4(3)- Maximum Number of Connected IDU without Branch Box 11 Minimum Number of Connected IDU with Branch Box 2 Minimum Number of Connected IDU without Branch Box 1 Minimum Connected Capacity with Branch Box BTU/H 12,000 Maximum Connected Capacity BTU/H 46,000 Piping Liquid Pipe Size O.D.(Flared) In.[mm] 3/8 [9.52] Gas Pipe Size O.D. (Flared) In.[mm] 5/8 [15.88] Total Piping Length when using Branch Box Ft. [m] 492 [150] Total Piping Length without Branch Box Ft. [m] 984 [ 300] Maximum Height Difference's, ODU above IDU Ft. [m] 164 [50] Maximum Height Difference's, ODU below IDU Ft. [m] 131 [40] Maximum Height Difference's, between branch boxes Ft. [m] 49 [15] Maximum Height Difference's, between branch boxes and IDU Ft. [m] 49 [15] Maximum Height Difference between IDU and IDU without branch box Ft. [m] 49 [15] Max. Piping Length between ODU and Branch Box Ft. [m] 180 [55] Farthest Piping Length from ODU to IDU with Branch Box Ft. [m] 262 [80] Farthest Piping Length from ODU to IDU without Branch Box Ft. [m] 492 [ 150] Farthest Piping Length after Branch Box Ft. [m] 82 [25] Total Piping Length between Branch Boxes and IDU Ft. [m] 311 [95] Maximum Number of Bends for IDU 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. when 1 or more PLA-A-EA7 connected a Branch box should be placed within the level between the outdoor unit and indoor units 'O 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Deflector Vertical Air Deflector Air Outlet Guide (1 Piece) Refrigeration Ball Valve -1/2" Refrigeration Ball Valve -1/4" Refrigeration Ball Valve - 318" ❑ ADV-1 Air Outlet Guide ❑ PAC-SH96SG-E (two pieces are required) Ball Valve ❑ BV12FFSI2 ❑ BV14FFSI2 ❑ BV38FFSI2 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 Branch Box ❑ PAC-MKA32BC Branch Box Branch Box ❑ PAC-MKA52BC Branch Box Enclosure ❑ BBE-1 Centralized Drain Pan Central Drain Pan ❑ PAC-SH97DP-E M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Control/Service Tool Maintenance Tool Interface ❑ PAC-USCMS-MN-1 Brazed Connection ❑ MSDD-50BR-E Distribution pipe Flare Connection ❑ MSDD-50AR-E Hail Guards Hail Guard ❑ HG-A2 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 Condensing Unit Mounting Pad: 24" x 42" x 3" ❑ ULTRILITE2 Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port Adapter Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Dual Fan Stand ❑ QSMS1802M 24" Dual Fan Stand ❑ QSMS2402M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand —12" High ❑ QSMS1202M Wind Baffle Front Wind Baffle ❑ WB-PA3 (two pieces are required) Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1 FREE SPACE(kound the unit) The ala9mmeelcwshowsa MMevampk ErpWation of {eNsularEdaiS are q+an In ire Inamusoo� mewala ew 1 •••R&M tGASPPawawMwlFlAl✓t)OA 2 •••ReB1 tLIDWDpyewaamM (UM) 09M(MF) '1 •••IMiw OSTMVAL4Ewmacbwbwfiw. Piping Knock -Out Hole Details 3 FOUNDATION BOLTS 4 PIPING -WIRING DIRECTIONS pleace.awrelMUMfinnly PipinpaMvnn�wnneMons MHi4fimMa4on)M19hN31B>)MM1s. wnbe neAe M1gndtlittfiwe'. (Ba16aMwaanemmwtEe Fmnt Rgm Raareea eeaw. wmlmwalwaryl MXZ-SM36NAMHZ MXZ-SM42NAMHZ 15.88 (5/8F) 426 <16-25/32> 485 <19-3/32> MXZ-SM48NAMHZ MXZ-SM60NAM 19.05 (3/4F) 393 <15-15/32> 450 <17-23/32> MXZ-SM36NAM MXZ-SM48NAM 15.88 (5/8F) 426 <16-25/32> 485 <19-3/32> MODEL NAME DIMENSION A DIMENSION B DIMENSION C Job Name: System Reference: Date: GENERAL FEATURES • Ducted air handler provides a solution to cool and heat larger zones • Highly efficient completely enclosed EC motor • Selectable external static pressure: 0.30, 0.50 and 0.80 in.WG with 3 fan speeds at each static setting • 1 inch R4.2 fiberglass free insulation reduces condensation and increases efficiency • Positive pressure cabinet with air leakage of less than 2.0% at 1.0 in. w.g. (Tested per ASHRAE Standard 193) • Unique blow through design allows simple coil cleaning when the blower is removed • Multi -position installation: horizontal (left or right), vertical (upflow) • Optional electric heat kit for additional heating capacity • Optional humidifier control, ERV control and auxiliary heat control • Optional downflow kit Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling Capacity', 3 Btu/h 33,000 Heating Capacity2, 3 Btu/h 33,500 Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187-253 Electrical Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Voltage: Indoor - Remote controller V DC 12 MCA A 4.13 Fan Motor Full Load Amperage A 3.3 Fan Motor Output W 244 Airflow Rate at Cooling, Dry CFM 910-910-767 Airflow Rate at Heating, Dry CFM 910-910-767 Sound Pressure Level (Cooling)' dB(A) 43-39-35 Sound Pressure Level (Heating)2 dB(A) 43-39-35 External Static Pressure in.WG 0.30-0.50-0.80 Drain Pipe Size In. (mm) 3/4 (19) Heat Exchanger Type Plate fin coil External Finish Color Black Unit Dimensions W: In. (mm) 21 (533) D: In. (mm) 21-5/8 (549) H: In. (mm) 43-3/4 (1,111) Package Unit Dimensions W: In. (mm) 22 (558) D: In. (mm) 28-3/4 (730) H: In. (mm) 48-3/8 (1,228) Unit Weight Lbs. (kg) 119 (54) Package Unit Weight Lbs. (kg) 141 (64) Refrigerant Type R410A Charge Lbs, oz 4,14 Piping Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (12.88) Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52) Notes: lCooling (Indoor // Outdoor) Nominal Conditions 2Heating at 47°F (Indoor // Outdoor) T 1 80 DB, 67 WB // 95 DB. 75 WB T 1 70 DB, 60 WB // 47 DB, 43 WB 3Capacity varies based on the number of indoor units operating and the model of the Multi -zone Outdoor Unit. For reference to connected capacity charts, please refer Multi -zone Outdoor Unit Operational Performance. Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Wireless Signal Receiver ❑ PAR-FA32MA-W Wireless Signal Receiver ❑ PAR-FA32MA-E Wireless Remote Controller Backlit, Wall -mounted, Wireless Controller Portable Central Controller ❑ PAR-FL32MA-E ❑ MHK1 ❑ MCCH1 Wired MA Controller ❑ PAR-33MAA Simple MA Controller ❑ PAC-YT53CRAU Touch MA Controller ❑ PAR-CT01 MAU-SB Airzone ZBS Wired Blueface Principal Controller White ❑ AZZBSBLUEFACECB Airzone ZBS Wired Think Controller White ❑ AZZBSTHINKCB Airzone ZBS Wireless Think Controller White ❑ AZZBSTHINKRB Airzone ZBS Wired Lite Controller White ❑ AZZBSLITECB Airzone ZBS Wireless Lite Controller White ❑ AZZBSLITERB Wired Remote Sensor ❑ PAC-SE41TS-E Wireless Temperature and Humidity Sensor ❑ PAC-USWHS003-TH-1 Outside Air Sensor for MHK1 ❑ MOS1 Flush Mount Remote Temperature Sensor ❑ PAC-USSEN001-FM-1 Wireless Interface ❑ PAC-USWHS002-WF-1 Thermostat Interface ❑ PAC-US444CN-1 kumo station® ❑ PAC-WHS01 HC-E USNAP Interface ❑ PAC-WHS01UP-E IT Extender ❑ PAC-WHS011E-E BACnet® and MODBUS® Interface ❑ PAC-UKPRC001-CN-1 External Fan / Heater Control Relay Adapter ❑ CN24RELAY-KIT-CM3 Connector cable for remote display ❑ PAC-SA88HA-EP ❑ PAC-SE55RA-E Connector for CN32 (remote on/off) Remote Operation Adapters ❑ PAC-SF40RM-E MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor ❑ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 Btu/h [recommended] ❑ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] ❑ X87-721 - 208/230V Drain Pan Level Sensor ❑ DPLS2 (30A/600V/UL) [fits 2" X 4" utility box] - Black ❑ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White ❑ TAZ-MS303W Separate Power Terminal Block Kit ❑ SPTB1 Electric Heat Lockout Control ❑ ETC-211000-MIT Downflow Kit ❑ DFK-M 5kW Electric Heater ❑ EH05-SVZ-M 8kW Electric Heater ❑ EH08-SVZ-M 10kW Electric Heater ❑ EH10-SVZ-M 1 Unable to use with wireless remote controller Specifications are subject to change without notice. © 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Left side view Unit:mm(in.) TcQ view, 026 Knockout Hole 0 26 Knockout Hole for electrical heat wiring 2-o4.6 Burring Holes for electric heal installation _ Secondary drain pipe of 9: 5(3/4) 314''FPT) - (i 76 (3 ) Air utlet .70.7(3-I/8) 0 - r Pdimarry dmin)pipa 79.053/4)3/4"FPT (Horizontal left) 43(I-3/4) 8(3/8 6 (2-5/8) Primq ff�tv drain)pipe o19OS(3/4) drain 8(3/8) 0®IL 43(1-3/4)(I-3/I6) 9613-5/8) Secondary d-in pipe (E5(3/4 dminPT) °9.p (Horizontal Right) - Secondary drain pipe (Emergency dmining) ol9.05(3/4) 3/4"FPT e26 Knockout Hole Indoor / Outdoor unit (connection) (Remote controller transmission) 55( 2-3/ I6l D Primary drain 0190 (3/4)13/4"FPT Control box ' SLOW RLTEA (Remove Blower Panel) Q Air Inlet A Model Nominal Filter Size Duct Connection SVZ-KP12NA 508 x 406.4 x 25.4 (20 x 16 x 1) 376 x 402 (14-13/16 x 15-7/8) SVZ-KP18NA SVZ-KP24NA SVZ-KP30NA 508 x 508 x 25.4 1 (20 x 20 x 1) 477 x 402 (18-13/16 x 15-7/8) SVZ-KP36NA Bottom view Unit:mm(in.) Note: Electrical entrance for SVZ located on both left and right side of the cabinet. See right or Left side view for knockout locations. I Right side view Model A B C D E F G H J Gas Pipe Liquid pipe SVZ-KP12NA 432 (17) 376 (14-13/16) 281 (11-1/8) 224 (8-7/8) 1,010.8 (39-13/16) 680 (26-13/16) 823 (32-7/16) 735.5 (29) 360 (14-3/16) o 9.52 (3/8) o 6.35 (1/4) SVZ-KP18NA 0 12.7 (1/2) SVZ-KP24NA o 15.88 (5/8) o 9.52 (3/8) SVZ-KP30NA 534 (21) 477 (18-13/16) 382.6 (15-1/8) 266.5 (10-1/2) 1,113.8 (43-7/8) 737 (29-1/16) 953.5 (37-9/16) 792 (31-3/16) 461 (18-3/16) SVZ-KP36NA FORM# SVZ-KP18NA FOR MULTI -ZONE HEAT PUMP SYSTEMS - 201903 # MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Et4 ua Intertek Specifications are subject to change without notice. Q 2019 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.