APPROVED ENG PLN BLD2024-1395+Site_Plan+10.22.2024_10.14.19_AM+4573572:BC -Ear►-; ��//
Zone Corner �-1__:Flag N
--------------=
Setbacks:
Required
Actual
1-SIB
12'3"
Front
5'8"E
Sides
Rear
Other
-------------
25�
@XISi
Height
APPROVED
Oct�22024
SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM
OWNER/CONTRACTOR IS RESPONSIBLE FOR
EROSION CONTROL AND DRAINAGE
1061
INA
PSN`NG
1A ' 40
(E) MAN GATE TO CROWN
ALL WORK SHALL BE PERFORMED ON CASTLE COMPOUND
PRIVATE PROPERTY. NO LANE
CLOSURES SHALL BE ALLOWED (E)OTI ER E POLE
(E) SUBJECT
PARCEL
e.' Ia
��/p/pNe• x
diQ A 'pNe / ..
r % G9�'� �O q a
0 oge O\
A
-\O
C A.
V
°N
x (E) OVERHEAD / p"Q/ A (E) GATE TO
POWER LINE / / x SUB STATION
pNe
p"p
x x (E) COMPOUND
\ I � I FENCE TO REMAIN
°"P x p"ems
f oae SUBJECT PARCEL
OWNER: PUBLIC UTILITY DISTRICT #1
SNOHOMISH COUNTY
ACREAGE: 0.69 ACRE(S)
PARCEL #: 270336001 14000
(E) ADJACENT PARCEL —\
(E) TREE CANOPY
ADJACENT PARCEL
OWNER: CONNEL MARISA
PARCEL #: 00434500001802
0
i
0
OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING
ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY
UTILITIES MAY REQUIRE A SEPERATE PERMIT.
% % % X X X X X
ADJACENT PARCEL
OWNER: VAN NOORT PETER
PARCEL #: 00434500001801
OVERALL PARCEL PLAN
SCALE: .. zs is, 30 1"= 15'9' (11x17) N
(E) TREE CANOPY
JC70vm
C CASTLE
8020 KATY FREEWAY
HOUSTON, TX 77024
I �
P. MARSHALL & ASSOCIATES
3545 WHITEHALL PARK DRIVE
SUITE 450 CHARLOTTE,
NORTH CAROLINA 28273
CROWN CASTLE BU #:
814645
/
I
SITE NAME:
°_ /
EAST EDMONDS
oo
I
x
ADJACENT PARCEL
SITE ADDRESS:
OWNER: EDMONDS WAY
/I
PARCEL #: 27033600117600
9620 EDMONDS WAY
o
�II
EDMONDS, WA 98020
SITE COORDINATES:
o
(E) STRUCTURES
47.790833
�
(TOTAL OF 3)
-122.361944
(E) SUB STATION EQUIPMENT
Applicant shall repair/replace all
damage to utilities or frontage
improvements in City right-of-way
per city standards that is caused or
occurs during the permitted project.
Nothing in the permit approval process shall be
interpreted as allowing or permitting the maintenance
of any currently existing illegal, nonconforming or
unpermitted building, structure or site condition which
is outside the scope of the permit application, regardless
of whether such building, structure or condition is
shown on the site plan or drawing. Such building,
structure or condition may be the subject of a separate
enforcement action.
ENGINEERING DIVISION
APPROVED AS NOTED
Jdl W..7.rti.rle u 11 /07/2024
VV
RECEIVED
Oct 22 2024
CITY OF EDMONDS
BLD2024-1395 DEVELOPMENT SERVICES
DEPARTMENT
57 -0 MONOPOLE
DECOMMISSION
51
ISSUED •
0
mom
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
PM&A PROJECT NUMBER:
24CCOWAN-0001
SHEET NUMBER: REVISION:
C1 0
oN
S Pt�NGRO
(E) MAN GATE TO CROWN
CASTLE COMPOUND
Ds3
PROVIDE TEMPORARY &
PERMANENT SEEDING TO ALL
DISTURBED AREAS NOT
COVERED BY GRAVEL (TYP.)
Ds3
REMOVE EXISTING CONCRETE PAD FOUNDATION.
CONTRACTOR TO CUT & REMOVE FOUNDATION
36" BELOW GRADE. CONTRACTOR TO BACKFILL
EMBEDDED PORTION OF HOLLOW PAD
FOUNDATION WITH SELECT STRUCTURAL FILL
COMPACTED TO 95% PROCTOR IN I'LIFTS.
NOTES
[Ds2]
DISTURBED AREA STABILIZATION
(WITH TEMPORARY SEEDING)
DISTURBED AREA STABILIZATION
DS3
(WITH PERMANENT VEGETATION)
SCF
SILT FENCE
Ds3 /+'
/+
DsGENERAL SITE NOTES �
/+ �j ]f; 3 Y1[ 7i�T lY
+/+ A. EXISTING COMPOUND (TO BE REMOVED). ALL CAS1
UNDERGROUND UTILITY LOCATIONS TO BE LOCATED 8020 KATY FREEWAY
AND REMOVED. HOUSTON, TX 77024
x
x � ODD <:D
�O�OQO�C
J O O O O
O �
CONTRACTOR TO RESTORE AFFECTED
O O AREAS WITH GRAVEL COVER. ADD
GRAVEL TO ALL EXISTING REMAINING
FOUNDATIONSENSURE LEVEL
AREA POST EQUIPMENT REMOVAL.
I I
I I
I(E) AT&T MOBILITY I
ICONCRETE PAD TO BE I
IREMOVED I
J
REMOVE ALL EXISTING UNDERGROUND
CONDUIT & SERVICE WIRE TO EXISTING y�l
EQUIPMENT AREAS 12" BELOW GRADE.
REMOVE EXISTING H-FRAME AFTER FINAL REMOVE EXISTING ICE BRIDGE. I
SERVICE SHUT OFF IS COMPLETED. REMOVE ALL POST
REMOVE ALL POST FOUNDATIONS FOUNDATIONS BELOW GRADE. x
BELOW GRADE. (TYP.) I
REMOVE EXISTING MONOPOLE TOWER AND FOUNDATION.
CONTRACTOR TO CUT & REMOVE FOUNDATION 36" BELOW
GRADE, CONTRACTOR TO BACKFILL EMBEDDED PORTION I
EXISTING OF HOLLOW TOWER FOUNDATION WITH SELECT
CHAIN -LINKED STRUCTURAL FILL COMPACTED TO 95% PROCTOR IN 1' LIFTS. k
FENCE
x x x x x x x x x x x x x
E) GRAVEL SUB
COMPOUND PLAN (STATION AREA
SCALE: o s o p• I 10 a p rxn l N
(E) CONCRETE
ACCESS APRON TO
TOWER LEASE AREA
(E) GRAVEL SUB
STATION AREA
B. EXISTING POWER CONDUCTORS, FIBER FEED &
PLUMBING FEED CONDUITS TO BE REMOVED. ALL
REMAINING EMPTY CONDUIT SHALL BE REMOVED 12"
BELOW GRADE AND BACKFILL, COVER WITH GRAVEL TO
LEVEL SURFACE.
C. THERE SHALL BE NO CLEARING, GRADING,
CONSTRUCTION, STORAGE, OR DISTURBANCE OF
VEGETATION EXCEPT AS PERMITTED IN WRITING BY THE
CITY OF EDMONDS SITE DEVELOPMENT MANAGER.
D. COMPLY WITH ALL BUFFER AND TREE PROTECTION
REQUIREMENTS.
E. COMPLY WITH ALL PERMANENT LANDSCAPE
REQUIREMENTS.
RECEIVED
Oct 22 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
I �
P. MARSHALL & ASSOCIATES
3545 WHITEHALL PARK DRIVE
SUITE 450 CHARLOTTE,
NORTH CAROLINA 28273
CROWN CASTLE BU #:
814645
SITE NAME:
EAST EDMONDS
SITE ADDRESS:
9620 EDMONDS WAY
EDMONDS, WA 98020
SITE COORDINATES:
47.790833
-122.361944
57'-0" MONOPOLE
DECOMMISSION
r
ISSUED •
0
mom
UNLESS THEY ARE ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL ENGINEER,
TO ALTER THIS DOCUMENT.
PM&A PROJECT NUMBER:
24CCOWAN-0001
SHEET NUMBER: REVISION:
C-2 0