Loading...
APPROVED ENG PLN BLD2024-1395+Site_Plan+10.22.2024_10.14.19_AM+4573572:BC -Ear►-; ��// Zone Corner �-1__:Flag N --------------= Setbacks: Required Actual 1-SIB 12'3" Front 5'8"E Sides Rear Other ------------- 25� @XISi Height APPROVED Oct�22024 SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE 1061 INA PSN`NG 1A ' 40 (E) MAN GATE TO CROWN ALL WORK SHALL BE PERFORMED ON CASTLE COMPOUND PRIVATE PROPERTY. NO LANE CLOSURES SHALL BE ALLOWED (E)OTI ER E POLE (E) SUBJECT PARCEL e.' Ia ��/p/pNe• x diQ A 'pNe / .. r % G9�'� �O q a 0 oge O\ A -\O C A. V °N x (E) OVERHEAD / p"Q/ A (E) GATE TO POWER LINE / / x SUB STATION pNe p"p x x (E) COMPOUND \ I � I FENCE TO REMAIN °"P x p"ems f oae SUBJECT PARCEL OWNER: PUBLIC UTILITY DISTRICT #1 SNOHOMISH COUNTY ACREAGE: 0.69 ACRE(S) PARCEL #: 270336001 14000 (E) ADJACENT PARCEL —\ (E) TREE CANOPY ADJACENT PARCEL OWNER: CONNEL MARISA PARCEL #: 00434500001802 0 i 0 OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. % % % X X X X X ADJACENT PARCEL OWNER: VAN NOORT PETER PARCEL #: 00434500001801 OVERALL PARCEL PLAN SCALE: .. zs is, 30 1"= 15'9' (11x17) N (E) TREE CANOPY JC70vm C CASTLE 8020 KATY FREEWAY HOUSTON, TX 77024 I � P. MARSHALL & ASSOCIATES 3545 WHITEHALL PARK DRIVE SUITE 450 CHARLOTTE, NORTH CAROLINA 28273 CROWN CASTLE BU #: 814645 / I SITE NAME: °_ / EAST EDMONDS oo I x ADJACENT PARCEL SITE ADDRESS: OWNER: EDMONDS WAY /I PARCEL #: 27033600117600 9620 EDMONDS WAY o �II EDMONDS, WA 98020 SITE COORDINATES: o (E) STRUCTURES 47.790833 � (TOTAL OF 3) -122.361944 (E) SUB STATION EQUIPMENT Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. ENGINEERING DIVISION APPROVED AS NOTED Jdl W..7.rti.rle u 11 /07/2024 VV RECEIVED Oct 22 2024 CITY OF EDMONDS BLD2024-1395 DEVELOPMENT SERVICES DEPARTMENT 57 -0 MONOPOLE DECOMMISSION 51 ISSUED • 0 mom UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A PROJECT NUMBER: 24CCOWAN-0001 SHEET NUMBER: REVISION: C1 0 oN S Pt�NGRO (E) MAN GATE TO CROWN CASTLE COMPOUND Ds3 PROVIDE TEMPORARY & PERMANENT SEEDING TO ALL DISTURBED AREAS NOT COVERED BY GRAVEL (TYP.) Ds3 REMOVE EXISTING CONCRETE PAD FOUNDATION. CONTRACTOR TO CUT & REMOVE FOUNDATION 36" BELOW GRADE. CONTRACTOR TO BACKFILL EMBEDDED PORTION OF HOLLOW PAD FOUNDATION WITH SELECT STRUCTURAL FILL COMPACTED TO 95% PROCTOR IN I'LIFTS. NOTES [Ds2] DISTURBED AREA STABILIZATION (WITH TEMPORARY SEEDING) DISTURBED AREA STABILIZATION DS3 (WITH PERMANENT VEGETATION) SCF SILT FENCE Ds3 /+' /+ DsGENERAL SITE NOTES � /+ �j ]f; 3 Y1[ 7i�T lY +/+ A. EXISTING COMPOUND (TO BE REMOVED). ALL CAS1 UNDERGROUND UTILITY LOCATIONS TO BE LOCATED 8020 KATY FREEWAY AND REMOVED. HOUSTON, TX 77024 x x � ODD <:D �O�OQO�C J O O O O O � CONTRACTOR TO RESTORE AFFECTED O O AREAS WITH GRAVEL COVER. ADD GRAVEL TO ALL EXISTING REMAINING FOUNDATIONSENSURE LEVEL AREA POST EQUIPMENT REMOVAL. I I I I I(E) AT&T MOBILITY I ICONCRETE PAD TO BE I IREMOVED I J REMOVE ALL EXISTING UNDERGROUND CONDUIT & SERVICE WIRE TO EXISTING y�l EQUIPMENT AREAS 12" BELOW GRADE. REMOVE EXISTING H-FRAME AFTER FINAL REMOVE EXISTING ICE BRIDGE. I SERVICE SHUT OFF IS COMPLETED. REMOVE ALL POST REMOVE ALL POST FOUNDATIONS FOUNDATIONS BELOW GRADE. x BELOW GRADE. (TYP.) I REMOVE EXISTING MONOPOLE TOWER AND FOUNDATION. CONTRACTOR TO CUT & REMOVE FOUNDATION 36" BELOW GRADE, CONTRACTOR TO BACKFILL EMBEDDED PORTION I EXISTING OF HOLLOW TOWER FOUNDATION WITH SELECT CHAIN -LINKED STRUCTURAL FILL COMPACTED TO 95% PROCTOR IN 1' LIFTS. k FENCE x x x x x x x x x x x x x E) GRAVEL SUB COMPOUND PLAN (STATION AREA SCALE: o s o p• I 10 a p rxn l N (E) CONCRETE ACCESS APRON TO TOWER LEASE AREA (E) GRAVEL SUB STATION AREA B. EXISTING POWER CONDUCTORS, FIBER FEED & PLUMBING FEED CONDUITS TO BE REMOVED. ALL REMAINING EMPTY CONDUIT SHALL BE REMOVED 12" BELOW GRADE AND BACKFILL, COVER WITH GRAVEL TO LEVEL SURFACE. C. THERE SHALL BE NO CLEARING, GRADING, CONSTRUCTION, STORAGE, OR DISTURBANCE OF VEGETATION EXCEPT AS PERMITTED IN WRITING BY THE CITY OF EDMONDS SITE DEVELOPMENT MANAGER. D. COMPLY WITH ALL BUFFER AND TREE PROTECTION REQUIREMENTS. E. COMPLY WITH ALL PERMANENT LANDSCAPE REQUIREMENTS. RECEIVED Oct 22 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT I � P. MARSHALL & ASSOCIATES 3545 WHITEHALL PARK DRIVE SUITE 450 CHARLOTTE, NORTH CAROLINA 28273 CROWN CASTLE BU #: 814645 SITE NAME: EAST EDMONDS SITE ADDRESS: 9620 EDMONDS WAY EDMONDS, WA 98020 SITE COORDINATES: 47.790833 -122.361944 57'-0" MONOPOLE DECOMMISSION r ISSUED • 0 mom UNLESS THEY ARE ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT. PM&A PROJECT NUMBER: 24CCOWAN-0001 SHEET NUMBER: REVISION: C-2 0