REV1 APPROVED BLD2021-0755+Plumbing_Plan+6.30.2022_9.18.42_AM+2963595
PLUMBING GENERAL NOTES: 1. CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. 4. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND 1 2 3 4 5 6 7 8 9 10 12 13 EQUIPMENT FOR SERVICE. 5. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135° OR MORE. 6. DOMESTIC PLUMBING MAINS TO BE COPPER IF OVER 2". 7. PROVIDE 8' SUDS RELIEF OFFSET ON SUD PRODUCING RISERS. SEE SHEET P6.2 FOR DETAIL. 8. ROUTE PLUMBING AS CLOSE TO THE PARKING CEILING AS POSSIBLE. SLOPE AT 1/4" PER FOOT. 9. PLUMBING CONTRACTOR HAS THE OPTION TO WET VENT RESTROOM GROUPS, OR MODIFY STACK PLUMBING SYSTEM. THE ALTERNATE PLUMBING DESIGN MUST COMPLY WITH THE 2018 UPC U 00 0 m CY 0 U W J D y 1 WASTE AND VENT PLAN - PARKING SCALE: 1/8" = 1'-0" PLUMBING KEYNOTES: 1. EXTEND 5'-0" FROM BUILDING AND CONNECT TO SITE UTILITIES. 2. 6" STORM PIPE FROM AREA DRAINS OUTSIDE OF BUILDING. SEE B ) CIVIL PLANS FOR CONTINUATION. 3. NOT USED. 4. 4" SS FROM ABOVE. 5. 2" V BELOW GRADE FROM SOI-1. ROUTE UP TO ROOF ON INDEPENDENT VENT THROUGH ROOF PER UPC SECTION 1017.1 6. 2" V UP. 7. 4" SS THROUGH PARKING SLAB. PROVIDE WCO-1 AT BASE. 8. ROUTE 6" SS, FROM ABOVE, THROUGH PARKING SLAB. PROVIDE WCO-1 AT BASE. 9. ROUTE PLUMBING AS CLOSE TO THE PARKING CEILING AS POSSIBLE. SLOPE AT 1/4" PER FOOT. 10. ROUTE 2" PUMPED WASTE FROM ELEVATOR SUMP PUMP (WITH INTEGRAL OIL ALARM) AS SHOWN. 11. ROUTE 3/4" CONDENSATE LINE (INSULATED) TO TAILPIECE OF NEAREST APPROVED SINK/LAV. 12. 4" GW FROM ABOVE. ROUTE BELOW SLAB AS SHOWN TO / � 1 EXTERIOR OF BUILDING. 13. 3" V BELOW GRADE FROM GREASE INTERCEPTOR (BY CIVIL). ROUTE UP TO ROOF ON INDEPENDENT VENT THROUGH ROOF. 14. ROUTE 3" INTAKE & EXHAUST COMBUSTION AIR THROUGH EXTERIOR WALL. ROUTE AS CLOSE TO CEILING AS POSSIBLE. 15. ROUTE 4" GW 5'-0" FROM BUILDING AND CONNECT TO SITE UTILITIES. SEE CIVIL DRAWINGS FOR CONTINUATION TO GREASE INTERCEPTOR.. 16. 3" SS FROM ABOVE. 17. 4" RD FROM ABOVE. 18. 5" RD FROM ABOVE. I19. TERMINATE PUMPED WASTE LINE ON TOP OF 8" SS MAIN. 370' 20. ROUTE 2" V UNDER PARKING SLAB UP IN WALL AS SHOWN. 15 21. CONNECT ROOF DRAINS AND AREA DRAINS (STORM) PIPES TO DETENTION VAULT. SEE CIVIL FOR DETAIL AND CONTINUATION. IE = 370' PIPES SHALL ENTER VAULT AT APPROX. 372' IE. 1C0-1 P3 22. ROUTE 4" SS TIGHT TO CEILING STRUCTURE ACROSS GARAGE ;C0-1 ENTRANCE, UNDER STAIRWAY, AS SHOWN. PIPE SHALL NOT ROUTE UNDER OR THROUGH DETENSION VAULT. 23. 8" SS FROM ABOVE. PROVIDE WCO-1 AT BASE. 24. PIPING ROUTED UNDER DRIVE AISLE. 25. PIPING ROUTED BELOW SLAB ON THIS LEVEL. 26. PIPING ROUTED AT CEILING LEVEL ON THIS LEVEL. 27. PROVIDE 24" DIAMETER, SUMP PIT FOR PUMP. SUMP PIT SHALL BE INSTALLED WITH A BOTTOM ELEVATION OF 365' TO ACCOMODATE PIPE DROP FROM EXTERIOR WALL. PROVIDE PUMP LIFT RAIL TO SERVICE PUMP WITHOUT ENTERING PIT. PLUMBING CONTRACTOR TO COORDINATE INTALLATION WITH STRUCTURAL ENGINEER. - H `� OF WASI/` 41741 N L 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. wwvl. dcengineerinq. net Phone:208.288.2181 Project:21 AMA01 N O 00 0') p Z z_ 0= Q W C 0 O 0 0 LdLd Z_ > > 10 J Q J _� 0 -0 - N z m I- Q LLl Z o U LU Q\ N U REVISION DATE REASON FOR ISSUE 7 03-25-22 RFI#22 9 05-25-22 RFI#15 10 05-31-22 RFI#23 11 06-07-22 RFI#27/CCD#2 13 06-27-22 RFI#41 PLUMBING WASTE & VENT - PARKING CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 SHEET NUMBER P2.0 00 CY m Q U w 2 1 2 3 4 5 6 7 8 9 10 12 13 1 WATER AND GAS PLAN - PARKING SCALE: 1/8" = V-0" PLUMBING GENERAL NOTES: 1. CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. 4. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND EQUIPMENT FOR SERVICE. 5. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135° OR MORE. 6. DOMESTIC PLUMBING MAINS TO BE COPPER IF OVER 2". 7. PROVIDE 8' SUDS RELIEF OFFSET ON SUD PRODUCING RISERS. SEE SHEET P6.2 FOR DETAIL. 8. ROUTE PLUMBING AS CLOSE TO THE PARKING CEILING AS POSSIBLE. SLOPE AT 1/4" PER FOOT. 9. PLUMBING CONTRACTOR HAS THE OPTION TO WET VENT RESTROOM GROUPS, OR MODIFY STACK PLUMBING SYSTEM. THE ALTERNATE PLUMBING DESIGN MUST COMPLY WITH THE 2018 UPC 0 PLUMBING KEYNOTES: 1. 4" CW FROM ABOVE. 2. ROUTE 4" CW, 4" HW, 1" HW (140) AND 1-1/4" HWR UP IN WALL. 3. ROUTE 1/2" CW UP. 4. ROUTE 1/2" HW UP. 5. 3/4" CW & 1/2" HW FROM ABOVE. ROUTE PLUMBING AS CLOSE TO THE CEILING AS POSSIBLE. 6. ROUTE 3/4" CW & 3/4" HW DOWN TO CLOTHES WASHERS. PROVIDE WATER HAMMER ARRESTOR ON CW AND HW. 7. ROUTE 3/4" CW UP IN WALL. 8. NOTUSED. 9. TAP OFF NG (2 PSI) AT LOWER PARKING AREA AND ROUTE AS CLOSE TO THE CEILING AS POSSIBLE. 10. ROUTE HW MAIN WITHIN 2 FT OF PUBLIC LAV/SINK FIXTURE HAVING 1/2" HW SUPPLY PIPE. 11. PROVIDE HEAT TRACE ON THE INSIDE OF PIPE INSULATION ON ALL EXPOSED DOMESTIC PIPING IN GARAGE. SEE ELECTRICAL PLANS FOR MORE INFORMATION. 12. PROVIDE WATER METER CAPABLE OF MONITORING 140 DEGREE HW SUPPLY TO FIRST FLOOR FIXTURES (COMMERCIAL). LOCATE WATER METER IN BOILER ROOM IN A SERVICABLE AND READABLE LOCATION. 13. PROVIDE WATER METER CAPABLE OF MONITORING 120 DEGREE HW SUPPLY TO UPPER FLOOR FIXTURES (RESIDENTS). LOCATE WATER METER IN BOILER ROOM IN A SERVICABLE AND READABLE LOCATION. C O F OWA Sk �/ v I�, \ 41741 GISTER��\� FSS/oNAL 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. mjf�� DC ENGINEERING Careful listening. Dynamic solutions. w w Ur. dre ngin e ering. n e t Phone:208.288.2181 Project:21 AMA01 N CD 00 O') (n Z O a F___ Z z 0= Q 0 W Cn 0 LL 0 O 0 LLI Z_ > > 10 J J o 0 O N Z co I- � LLJ it Z C:) U) Q LU N U a REVISION DATE REASON FOR ISSUE A 08-20-21 CITY COMMENTS #01 12 06-20-22 RFI#46 PLUMBING WATER & GAS - PARKING CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 SHEET NUMBER P3.0 > D 0 t ,3 u J ll 1 2 3 4 5 6 7 8 9 10 12 13 1 WATER AND GAS PLAN - 2ND FLOOR SCALE: 1/8" = V-0" �I PLUMBING GENERAL NOTES: 1. CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. 4. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND EQUIPMENT FOR SERVICE. 5. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135° OR MORE. 6. DOMESTIC PLUMBING MAINS TO BE COPPER IF OVER 2". 7. PROVIDE 8' SUDS RELIEF OFFSET ON SUD PRODUCING RISERS. SEE SHEET P6.2 FOR DETAIL. 8. ROUTE PLUMBING AS CLOSE TO THE PARKING CEILING AS POSSIBLE. SLOPE AT 1/4" PER FOOT. 9. PLUMBING CONTRACTOR HAS THE OPTION TO WET VENT RESTROOM GROUPS, OR MODIFY STACK PLUMBING SYSTEM. THE ALTERNATE PLUMBING DESIGN MUST COMPLY WITH THE 2018 UPC C O F OWASkJx� v � 41741 ISTER��\� FSS/oNAL �� 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.dcengineering.net Phone:208.288.2181 Project:21 AMA01 cD 04 O 00 M 0 0 Z z 0 = Q 0 W 0 LL 0 O 0 LLI z > > J Q J 0 -0 Of O N T — o i z m I— 0 W Z N U Q Q LU cal U a REVISION DATE REASON FOR ISSUE 4 01-03-22 ADDENDUM #03 A 08-20-21 CITY COMMENTS #01 15 06-29-22 RFI#45 PLUMBING WATER & GAS -SECOND FLOOR CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 SHEET NUMBER P3. L 14 PLUMBING GENERAL NOTES: 1. CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. 2. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, 1 2 3 4 5 6 7 8 9 10 12 13 DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. 3. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. 4. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND EQUIPMENT FOR SERVICE. 5. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135° OR MORE. 6. DOMESTIC PLUMBING MAINS TO BE COPPER IF OVER 2". 7. PROVIDE 8' SUDS RELIEF OFFSET ON SUD PRODUCING RISERS. SEE SHEET P6.2 FOR DETAIL. 8. ROUTE PLUMBING AS CLOSE TO THE PARKING CEILING AS POSSIBLE. SLOPE AT 1/4" PER FOOT. 9. PLUMBING CONTRACTOR HAS THE OPTION TO WET VENT RESTROOM GROUPS, OR MODIFY STACK PLUMBING SYSTEM. THE ALTERNATE PLUMBING DESIGN MUST COMPLY WITH THE 2018 UPC I I I I I I I I I I I PLUMBING KEYNOTES: 1. 3/4" CW & HW RISERS, FROM BELOW, UP TO 6TH LEVEL. SEE P3.5 ��H�1 FOR CONTINUATION, AND RISER DIAGRAM 1 ON P6.3. ® 2. 3/4" CW RISER, FROM BELOW, UP TO 6TH LEVEL. SEE P3.5 FOR CONTINUATION, AND RISER DIAGRAM 2 ON P6.3. 3. 1" CW & HW RISERS, FROM BELOW, UP TO 6TH LEVEL. SEE P3.5 t3 J FOR CONTINUATION, AND RISER DIAGRAM 3 ON P6.3. O 13 ® IL-C1 IL-B2 - 1 IL-66 13 @ -B1 IL-C3 4. 3/4" CW & HW RISERS, FROM BELOW, UP TO 6TH LEVEL. SEE P3.5 4 FOR CONTINUATION, AND RISER DIAGRAM 4 ON P6.3. 13 13 15 5. 3/4" CW & HW RISERS, FROM BELOW, UP TO 6TH LEVEL. SEE P3.5 4 5 O _ - 4 ® 13 13 13 FOR CONTINUATION, AND RISER DIAGRAM 5 ON P6.3. 5 ( 7�1 4 ° 5 13 15 ° 13 ° DW 6. 3/4" CW UP AND DOWN IN WALL. 1-1/4" HWR UP AND DOWN IN 1 2 DW - 1 UU DW ^ 13 KS 1 WALL. SEE P3.1 AND P3.5 FOR CONTINUATION. L��F N (� �.��y 5 (P) 3 7. 3/4" CW FROM BELOW. 2 2 EF. 1 1/4 HW <h 2 2 14 13 14 (T�'P) 8. ROUTE 1/2" CW UP IN WALL ABOVE. 1" HW 1 1/2" HW R_E_F = REF I ° REF 1 HW ® ® _ � _ _ REF = ,_ REF �� 1 1/4" HW 13 1 1/4" HW C 9. ROUTE 1/2" CW AND HW UP IN WALL ABOVE. J 19 19 580 HW FU 19 19 726 HW FU (TYP)- - 609 HW FU 669 HW FU r 19 699 HW FU r 19 (31 GPM) 19 wC-� (TYP) 10. NG (2 PSI) UP AND DOWN IN WALL. 1 2 O 2" HWR 2" HWR 2" HWR 19 14 1 1/2" HWR 1 1/2" HWR (27 GPM) (31 GPM) 11 (TYP) 11. 1" CW UP AND DOWN IN WALL. 1 1/4" HW g (16 GPM) 3 19 1 18 (25 GPM) gO 8O 1/2" CW 19 1 1/2 HW 12. 1" CW UP AND DOWN IN WALL. 3/4" HW UP IN WALL. (D 13. NOT USED. { 0 ❑ A . DIR. OFFI E 1 2 rt 5 19 9 STOR. 3 ° 2 ° 1 ILL [if I f = = 14. 1/2" CW FROM BELOW. i�N4 - co ,--„--, 1 1/4" HW 15. ROUTE KITCHEN PLUMBING UNDER FLOOR AS NECESSARY. O DW -B1 9 ❑ - - i ELEV. WAITING 3/4" CW 19 ° 16. NOT USED. w 5 SS-1 �a 17. 3/4" CW & HW RISERS, FROM BELOW, UP TO 5TH LEVEL. SEE P3.5 3 4 47 FOR CONTINUATION, AND RISER DIAGRAM 6 ON P6.3. 19 � 6 4 ° LO ' IDF IL-C4 ® 5 -B7 N�" IL-05 18. PROVIDE FLOW BALANCE DEVICE ON 1/2" HWR LINE, WITH 1 1/4" HW :DE) ® 17 18 w p ACCESS IN CEILING, BALANCE TO 1 GPM. 9 4 -�-- EF. � _� 8 3/4" HW 19. PROVIDE FLOW BALANCE DEVICE ON 1/2" HWR LINE, WITH � r 19 O O SSUMPTIONS: ASSUMPTIONS: �� ACCESS IN CEILING, BALANCE TO 2 GPM. APACITY - 3500 CAPACITY - 4000 r s ibs = 0 5 3/4" CW D PEED - 200 fpm SPEED - 200 fpm = U' 5 3 11 ® AB HEIGHT-8'- CAB HEIGHT-8'- ELEC/IDF �N I L-A2 19 1" CW ( ` 10 1 1/4" HW- Ii w a ° 4 =j EF. T SH _v ---- ® ® 2 g 9 9 IL-B2 +DEN 19 13/4" HW " r..� 3 5 0LL 0 1 2 1 1/4" HW 19 N 3 2 1 19 2 I G J 19 1 1/4" HW 3/4" H W LjL M N O D 4 CO° 1 -131 2 1 IL-133 11 ILL 19ILL 1 1/4" HW 5 IL-B5 o w U_�2UD] °=o M 0 4 ® �00 4 [°] IDW 3 3 DW Q I IL-132 1 1 5ILL 0 H STAIR - 1 [Ell 1STAIR-02 11/4"HW19�1 ® 3 Cy �� 19FA 2 19 212 HW FU 3/4" HWR 1" HWR 1 1/4" HWR 263 HW FU 1 1/4" HWR 1 1/4" HWR -f 1 1 1/2" HW (2 GPM) 19 1g (6 GPM) 1g (8 GPM) 1g 1g (12 GPM) 1g 1 1/4" HW LLJ �EJF HW R F =_ EF. EF. EF. EF. EF. 4 EF. 7--L2 ° N f�lf�l DW ° D DW DW DW ° DW DW DW IL 1" HW AL L-C2 ol 5 5 5 OF 5 5 01 5 1 2 ® IL-B5 IL-B2 U IL-B6 IL-B6 IL-B6 0 IL-B6 0 IL-136 I I I ® 0 0 O O O (D O I I I I I I I c6 m Q I I I w J 0 U) C WATER AND GAS PLAN - 5TH FLOOR E SCALE: 1/8" = V-0" a 0 N 'o N O N_ m Q J C O F OWASkJ/� v � 41741 GISTER�� \� FSS/oNAL �G 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www.dcengineer'ng.net Phone:208.288.2181 Project:21 AMA01 04 O 00 CY) p 0 Z z O = Q 0 W o 0 O Lu z 0 ; > J > J o 0 C) p N - o I` z m W Z N U) Q � � Q cal U a REVISION DATE REASON FOR ISSUE A 08-20-21 CITY COMMENTS #01 15 06-29-22 RFI#45 PLUMBING WATER & GAS - FIFTH FLOOR CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 SHEET NUMBER P3. PLUMBING FIXTURE SCHEDULE MANUFACTURER & PIPING CONNECTIONS TRAP WASTE VENT C.W. H.W. FIXTURE NO. DESCRIPTION MODEL SIZE FEATURES & ACCESSORIES B-1 BATHTUB/SHOWER AQUATIC 2603CTH 60"x33"x74"H 1-1/2" 2" 1-1/2" 1/2" 1/2" ONE-PIECE FIBERGLASS TUB/SHOWER, WHITE; INTEGRAL OVERFLOW. 1-1/2", 17 GAUGE, P-TRAP. (ADA COMPLIANT) W/SYMMONS HAND HELD PROVIDE POWDER -COATED WHITE GRAB BARS AND REMOVABLE TRI-FOLD SEAT. FURNISH WITH SHOWER SYSTEM CURTAIN ROD. ALL UNITS TO HAVE FULL WALL BACKING AT ALL WALLS. VERIFY RIGHT/LEFT CONFIGURATION WITH ARCHITECTURAL PLANS. 1.5 GPM. BS-1 BEAUTY SINK PS DESIGN - 1" - 1/2" 1/2" PS DESIGN PROCUREMENT RETRACTABLE COMPACT MANI/PEDI CHAIR. INSTALL PER RETRACTABLE COMPACT PROCUREMENT MANUFACTURER INSTRUCTION. 110V/220V AVAILABLE. 7.9 AMP MAX FOR CHAIR AND TUB. 4 AMP MANI/PEDI CHAIR RETRACTABLE COMPACT MAX RELAXOR. 1.5 AMP MAX DISCHARGE PUMP. COORDINATE WITH MECHANICAL CONTRACTOR MANI/PEDI CHAIR PS DESIGN FOR VENTILATION REQUIRMENTS. 1.75 GPM. BS-2 BEAUTY SINK 60"x24" 1-1/4" 2" 2" 1/2" 1/2" PS DESIGN PROCUREMENT LUXE WET STATION. INSTALL PER MANUFACTURER INSTUCTION. WET STATION PROCUREMENT 1.75 GPM. LUXE WET STATION - - - - PROVIDE CAST BRONZE BODY NOZZLE AND WALL FLANGE. DS-1 DOWNSPOUT NOZZLE JAY R SMITH LINE SIZE - 1770-T (SEE PLANS) 18-3/8"x19" 1-1/4"x1-1/ BARRIER FREE BI-LEVEL ELECTRIC WATER COOLER, HIGH POLISHED STAINLESS STEEL DRINKING EWC-1 ELECTRIC WATER COOLER ELKAY EZSTL8WSK 1-1/2" 1-1/2" 1/2" - (ADA COMPLIANT HI-LO) W/PUSH BUTTON EACH 2" FOUNTAINS WITH BUBBLER HEADS, PUSH BUTTONS, WASTE STRAINERS, MATCHING BACK PANEL, ACTIVATION ACCESS PANEL, VANDAL RESISTANT BOTTOM PLATES, AND COMPLETE MOUNTING SYSTEM. PROVIDE WITH EZH2O BOTTLE FILLING STATION. 115/1/60, 5.0 FLA, 370 RATED WATTS. DELIVERS 8.0 GAL CHILLED WATER PER HOUR. MOUNT PER ADA REQUIREMENTS. ROUND, MEDIUM DUTY FINISHED FLOOR CLEANOUT. PROVIDE WITH ROUND ADJUSTABLE NICKEL FCO-1 FLOOR CLEANOUT JAY R SMITH LINE SIZE - - - - - (FINISHED FLOOR) SERIES 4020S (SEE PLANS) BRONZE TOP, GASKET SEAL, & TAPERED ABS PLUG. 2" MINIMUM. FCO-2 FLOOR CLEANOUT JAY R SMITH LINE SIZE - - - - - ROUND, MEDIUM DUTY UNFINISHED FLOOR CLEANOUT. PROVIDE WITH ROUND ADJUSTABLE CAST (UNFINISHED FLOOR) SERIES 4240S (SEE PLANS) IRON TOP, GASKET SEAL, & TAPERED ABS PLUG. 2" MIN. FOR USE IN UNFINISHED LOCATIONS ONLY. FDA FLOOR DRAIN JAY R SMITH 2"/3" 2"/3" 2" TRAP - ROUND NICKEL BRONZE STRAINER; TRAP PRIMER CONNECTION. FLOOR DRAINS IN THE 2005Y--A05-NB PRIMER COMMERCIAL KITCHEN ARE NOT REQUIRED TO HAVE TRAP PRIMERS. FS-1 FLOOR SINK JAY R SMITH 12"x12" 2"/3" 2"/3" 2" TRAP - ACID RESISTANT COATED CAST IRON, 12" SQUARE, 10" DEEP WITH A. R. COATED CAST IRON 3440Y--C-P-12 10" DEEP PRIMER STRAINER, NO -HUB OUTLET, HALF GRATE COVER, TRAP PRIMER CONNECTION. FLOOR SINKS IN THE COMMERCIAL KITCHEN ARE NOT REQUIRED TO HAVE TRAP PRIMERS. FS-2 FLOOR SINK JAY R. SMITH 12"x12" 4" 4" 2" TRAP - ACID RESISTANT COATED CAST IRON, 12" SQUARE, 10" DEEP WITH A. R. COATED CAST IRON PRIMER STRAINER, NO -HUB OUTLET, HALF GRATE COVER, TRAP PRIMER CONNECTION. GCO-1 GRADE CLEANOUT JAY R. SMITH LINE SIZE - - - - - CAST IRON TOP, ABS PLUG WITH GASKET SEAL. SIZE TO MATCH WASTE PIPING. 4220S (SEE PLANS) HB-1 HOSE BIBB WOODFORD 67 - - - 3/4" - ANTI -SIPHON, AUTOMATIC DRAINING WITH ONE REMOVABLE OPERATING KEY TO BE FURNISHED (FREEZE -PROOF) WITH EACH HYDRANT. FLUSH MOUNT AT 18" ABOVE FINISHED GRADE. HB-2 HOSE BIBB WOODFORD RHY2-MS - 1/8" - 1" - ANTI -SIPHON, AUTOMATIC DRAINING, ROOF MOUNTED. (ROOF) (FREEZELESS ROOF HYDRANT) - HB-3 HOSE BIBB WOODFORD 22 - - 3/4" 3/4" ANTI -SIPHON, HOT AND COLD, BRONZE, VACUUM BREAKER, 4" WITH METAL HANDLE. PROVIDE WITH (FREEZE -PROOF) MIXING VALVE. KS-1 KITCHEN SINK -UNITS ELKAY ELUHAD211545PD 23-1/2"x18-1/4"x 1-1/2" 2" 1-1/2" 1/2" 1/2" 18 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE (SINGLE COMPARTMENT, W/GROHE EUROSMART 4-3/8" STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN; 17 GA. UNDERMOUNT) 30306000 CONTINUOUS DRAIN ASSEMBLY. PROVIDE "PASCO" AIR GAP FITTING FOR DISHWASHER CONNECTION. PROVIDE WITH WALL CLEANOUT (WCO-1). 1.75 GPM. KS-2 KITCHEN SINK -UNITS ELKAY ELUHAD211545PD 23-1/2"x18-1/4"x 1-1/2" 2" 1-1/2" 1/2" 1/2" 18 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE (SINGLE COMPARTMENT, W/GROHE EUROSMART 4-3/8" STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN (REAR UNDERMOUNT, 30306000 PUNCH); 17 GA. CONTINUOUS DRAIN ASSEMBLY. PROVIDE "PASCO" AIR GAP FITTING ON COUNTER ADA COMPLIANT) FOR DISHWASHER CONNECTION. PROVIDE WITH OFFSET GRID DRAIN ASSEMBLY FOR WHEELCHAIR; PROVIDE ADA INSULATION KIT. PROVIDE WITH WALL CLEANOUT (WCO-1). 1.75 GPM. L-1 LAVATORY -UNIT AMERICAN STANDARD 19"x15" 1-1/4" 1-1/2" 1-1/2" 1/2" 1/2" VITREOUS CHINA, WHITE, OVAL UNDERMOUNT; 0.5 GPM VANDAL RESISTANT AERATOR. PROVIDE (UNDERMOUNT) OVALYN UNIVERSAL WITH K-8999 TRAP AND K-7131-A. PROVIDE 1/2" X 3/8" ANGLE STOPS. PROVIDE WITH WATTS LFMMV ACCESS SINK THERMOSTATIC MIXING VALVE. SET MIXING VALVE TEMPERATURE PER THE CURRENT ADOPTED 9482.000 (UNDERMOUNT) VERSION OF THE ADA STANDARDS, PLUMBING CODE, AND LOCAL AHJ. EXCLUDE OVERFLOW. W/GROHEEUROSMART 3264300A FAUCET 1/2" VITREOUS CHINA, WHITE, OVAL UNDERMOUNT; 0.5 GPM VANDAL RESISTANT AERATOR. PROVIDE L-2 LAVATORY -UNIT AMERICAN STANDARD 19"x15" 1-1/4" 1-1/2" 1-1/2" 1/2" (UNDERMOUNT, OVALYN UNIVERSAL WITH K-8999 TRAP AND K-7131-A. PROVIDE 1/2" X 3/8" ANGLE STOPS. PROVIDE WITH WATTS LFMMV ADA COMPLIANT) ACCESS SINK THERMOSTATIC MIXING VALVE. SET MIXING VALVE TEMPERATURE PER THE CURRENT ADOPTED 9482.000 (UNDERMOUNT) VERSION OF THE ADA STANDARDS, PLUMBING CODE, AND LOCAL AHJ. EXCLUDE OVERFLOW. W/GROHEEUROSMART 3264300A LAVATORY -PUBLIC FAUCET AMERICAN STANDARD 1/2" VITREOUS CHINA, WHITE, OVAL UNDERMOUNT; 0.5 GPM VANDAL RESISTANT AERATOR. PROVIDE L-3 19"x15" 1-1/4" 1-1/2" 1-1/2" 1/2" (UNDERMOUNT, ADA OVALYN UNIVERSAL WITH K-8999 TRAP AND K-7131-A. PROVIDE 1/2" X 3/8" ANGLE STOPS. PROVIDE WITH WATTS LFMMV COMPLIANT) ACCESS SINK THERMOSTATIC MIXING VALVE. SET MIXING VALVE TEMPERATURE PER THE CURRENT ADOPTED 9482.000 (UNDERMOUNT) VERSION OF THE ADA STANDARDS, PLUMBING CODE, AND LOCAL AHJ. EXCLUDE OVERFLOW. W/GROHEEUROSMART 3264300A FAUCET OD-1 OVERFLOW DRAIN JAY R SMITH LINE SIZE - - - - - PROVIDE WITH NO HUB OUTLET, SUMP RECEIVER, UNDERDECK CLAMP, AND ROUND CAST IRON 1070Y-R-C-CID (SEE PLANS) DOME STRAINER. COORDINATE ROOF INSULATION DEPTH WITH ARCHITECT. PD-1 PARKING DECK DRAIN ZURN Z533 9" DIA 4" 4" 2" - - 9" DIA HEAVY DUTY PARKING DECK DRAIN W/ SUPPORT FLANGE. PROVIDE SURESEAL WATERLESS TRAP SEAL OR APPROVED EQUAL. RD-1 ROOF DRAIN JAY R SMITH LINE SIZE - - - - - PROVIDE WITH NO HUB OUTLET, SUMP RECEIVER, UNDERDECK CLAMP, AND ROUND CAST IRON 1010Y-R-C-CID (SEE PLANS) DOME STRAINER. COORDINATE ROOF INSULATION DEPTH WITH ARCHITECT. RPB-1 REDUCED PRESSURE WATTS LF957 LINE SIZE - - - LINE - PROVIDE WITH 1/4 TURN BALL VALVE AND STRAINER. PROVIDE MANUFACTURER'S AIR GAP FITTING BACKFLOW PREVENTER SIZE AS REQUIRED. RPB-2 REDUCED PRESSURE WATTS SS009-QT-S LINE SIZE - - - LINE - PROVIDE WITH 1/4 TURN BALL VALVE AND STAINLESS STEEL STRAINER. BACKFLOW PREVENTER SIZE S-1 SINK - LAUNDRY RM ELKAY ELUHAD211545PD 23-1/2"x18-1/4"x 1-1/2" 2" 1-1/2" 1/2" 1/2" 18 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE (SINGLE COMPARTMENT, W/GROHE EUROSMART 4-3/8" STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN (REAR SELF RIM COUNTERTOP, 30306000 PUNCH); 17 GA. CONTINUOUS DRAIN ASSEMBLY. PROVIDE "PASCO" AIR GAP FITTING ON COUNTER ADA COMPLIANT) FOR DISHWASHER CONNECTION. PROVIDE WITH OFFSET GRID DRAIN ASSEMBLY FOR WHEELCHAIR; PROVIDE ADA INSULATION KIT. PROVIDE WITH WALL CLEANOUT (WCO-1). 1.75 GPM. S-2 NOT USED S-3 SINK - BREAK RM & FAMILY ELKAY ELUHAD211545PD 23-1/2"x18-1/4"x 1-1/2" 2" 1-1/2" 1/2" 1/2" 18 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE RM W/GROHE EUROSMART 4-3/8" STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN (REAR (DOUBLE COMPARTMENT, 30306000 PUNCH); 17 GA. CONTINUOUS DRAIN ASSEMBLY. PROVIDE "PASCO" AIR GAP FITTING ON COUNTER UNDERMOUNT, FOR DISHWASHER CONNECTION. PROVIDE WITH OFFSET GRID DRAIN ASSEMBLY FOR WHEELCHAIR; ADA COMPLIANT) SINK - SALON HAND WASH ELKAY ELUHAD1 1 1655PD 14"x18-1/2"x PROVIDE ADA INSULATION KIT. PROVIDE WITH WALL CLEANOUT (WCO-1). 1.75 GPM. S4 1-1/2" 2" 1-1/2" 1/2" 1/2" 18 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE (SINGLE COMPARTMENT, W/GROHE EUROSMART 5-3/8" STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN; 17 GA. SELF RIM COUNTERTOP, 30306000 CONTINUOUS DRAIN ASSEMBLY. PROVIDE WITH WALL CLEANOUT (WCO-1). 1.75 GPM. ADA COMPLIANT) S-5 SINK - ELKAY ELUHAD211545PD 23-1/2"x18-1/4"x 1-1/2" 2" 1-1/2" 1/2" 1/2" 18 GAUGE STAINLESS STEEL; PUNCHED TO ACCOMMODATE FAUCET. 1/2" x 3/8" ANGLE THEATER/COMMUNITY RM W/GROHE EUROSMART 4-3/8" STOP WITH OVAL HANDLE AND FLEXIBLE RISERS; 17 GAUGE TRAP. ELKAY LKJ-35 DRAIN (REAR W/DISHWASHER 30306000 PUNCH); 17 GA. CONTINUOUS DRAIN ASSEMBLY. PROVIDE "PASCO" AIR GAP FITTING ON COUNTER CONNECTION FOR DISHWASHER CONNECTION. PROVIDE WITH OFFSET GRID DRAIN ASSEMBLY FOR WHEELCHAIR; (DOUBLE COMPARTMENT, PROVIDE ADA INSULATION KIT. PROVIDE WITH WALL CLEANOUT (WCO-1). 1.75 GPM. UNDERMOUNT, ADA COMPLIANT) SHOWER AQUATIC 1603BFSTD ACRYLX WITH INTEGRAL DRAIN; PROVIDE 2.5 GPM FLOW RESTRICTOR. PROVIDE SYMMONS 9603 SH-1 62"x36"x77"H 2" 2" 1-1/2" 1/2" 1/2" W/SYMMONS PLR SINGLE HANDLE PRESSURE BALANCING SHOWER VALVE WITH HAND HELD SHOWER SYSTEM, 9603 PLR HAND HELD HOSE VACUUM BREAKER AND 30" SLIDE BAR, SHOWER CURTAIN AND ROD, WHITE FOLD -DOWN SHOWER SYSTEM PHENOLIC SEAT PER ADA REQUIRMENTS. SUPPORT AND REQUIRED GRAB BAR BLOCKING. GRAB BARS TO BE WHITE POWDER COAT FINISH. PROVIDE WITH COLLAPSIBLE DAM #M-THR132-60 AND END CAP #1CWRACAP. VERIFY RIGHT/LEFT CONFIGURATION WITH ARCHITECTURAL PLANS. SH-2 SHOWER AQUATIC 1603BFSTD 62"x36"x77"H 2" 2" 1-1/2" 1/2" 1/2" ACRYLX WITH INTEGRAL DRAIN; PROVIDE 2.5 GPM FLOW RESTRICTOR. PROVIDE SYMMONS 9603 (ADA COMPLIANT) W/SYMMONS PLR SINGLE HANDLE PRESSURE BALANCING SHOWER VALVE WITH HAND HELD SHOWER SYSTEM, 0368-2HSB-LHS HAND HOSE VACUUM BREAKER AND 30" SLIDE BAR, SHOWER CURTAIN AND ROD, WHITE FOLD -DOWN HELD PHENOLIC SEAT PER ADA REQUIRMENTS. SUPPORT AND REQUIRED GRAB BAR BLOCKING. GRAB SHOWER SYSTEM BARS TO BE WHITE POWDER COAT FINISH. PROVIDE WITH COLLAPSIBLE DAM #M-THR132-60 AND END CAP #1CWRACAP. PROVIDE THIS FIXTURE GROUP WITH 25 REMOVABLE THRESHOLDS FOR ZURN ATTIC STOCK. SOI-1 SAND AND OIL 30"x20"x20" - 3" 1-1/2" - - SAND AND OIL INTERCEPTOR, 3" INLET/OUTLET, 30 GPM FLOW, 21 GALLON CAPACITY INTERCEPTOR Z1186-700 SS-1 SERVICE SINK FIAT MSB-2424 24"x24"x12" 3" 3" 1-1/2" 1/2" 1/2" MOLDED STONE; FLOOR MOUNTED, SQUARE. INTEGRAL DRAIN. STOPS IN SHANK. CAST IRON TRAP. W/FIAT 830-AA 832-AA HOSE AND WALL HOOK, 889-CC STAINLESS STEEL MOP HANGER AND MSG-2424 STAINLESS FAUCET STEEL SPLASH PANELS. PROVIDE WITH WALL CLEANOUT (WCO-1). TD-1 TRENCH DRAIN POURED IN PLACE 4" 4" 2" TRAP - POURED IN PLACE CONCRETE TRENCH. PROVIDE 4 INCH FLOOR DRAIN LISTED, IN BOTTOM OF LOW (LAUNDRY) BY OTHERS W/J R. PRIMER SIDE OF TRENCH. COORDINATE SIZE WITH ACTUAL LAUNDRY EQUIPMENT, COORDINATE LOCATION SMITH 2110-D WITH ARCHITECT AND GENERAL CONTRACTOR. TD-2 TRENCH DRAIN (CLASS C) J R. SMITH 966 6" WIDE 3" 3" 2" - - PROVIDE 3 INCH FLOOR DRAIN LISTED, IN BOTTOM OF LOW SIDE OF TRENCH. COORDINATE CLASS C HEAVY DUTY LOCATION WITH ARCHITECT AND GENERAL CONTRACTOR. TP-1 TRAP PRIMER JAY R. SMITH - - - 1/2" - PROVIDE SCREWDRIVER STOP VALVE UPSTREAM FOR MAINTENANCE. PROVIDE APPROPRIATE 2699-1 KOHLER K-4991-ET ACCESS PANEL FOR MAINTENANCE. U-1 URINAL 3/4" TOP SPUD - 2" 2" 3/4" - VITREOUS CHINA; WALL MOUNTED SIPHON -JET, 1.0 GPF. PROVIDE JAY R. SMITH 636 CARRIER WITH (ADA COMPLIANT) W/SLOAN 186 FLUSH HANGER PLATE. MOUNT PER ADA REQUIREMENTS. PROVIDE WITH WALL CLEANOUT (WCO-1). VALVE WB-1 WASHER BOX WATER-TITE 4700 8.25"x6.125"x 2" 2" 2" 1/2" 1/2" FLUSH WALL MOUNT. PROVIDE WITH 1/4 TURN, LEVER HANDLE, CHROME BALL VALVES. PROVIDE (CLOTHES WASHER 3.75"D WITH WATER HAMMER ARRESTOR WADE MODEL W-5 OR APPROVED EQUAL. HOOK-UP) WC-1 WATER CLOSET- UNITS PROFLO GILPIN ELONGATED - 3" 2" 1/2" - VITREOUS CHINA; FLOOR MOUNTED. PROVIDE VITREOUS CHINA TANK AND TANK COVER, POLISHED (PRESSURE ASSISTED PF1603PAWH WITH BOWL CHROME TRIP LEVER, BOLT CAPS, CLOSET SWEEP, SEAT FLANGE AND GASKET. CLOSED FRONT TANK TYPE) PF1600 TANK SEAT, WHITE, WITH COVER. PROVIDE 1/2"x3/8" ANGLE STOP WITH OVAL HANDLE AND FLEXIBLE RISERS. PROVIDE WITH MANUFACTURER'S PRESSURE ASSISTED FLUSHING SYSTEM. 1.6 GPF. WC-2 WATER CLOSET- UNITS PROFLO GILPIN ELONGATED - 3" 2" 1/2" - VITREOUS CHINA; FLOOR MOUNTED. PROVIDE VITREOUS CHINA TANK AND TANK COVER, POLISHED (PRESSURE ASSISTED PF1603PAWH WITH BOWL CHROME TRIP LEVER, BOLT CAPS, CLOSET SWEEP, SEAT FLANGE AND GASKET. CLOSED FRONT TANK TYPE, PF1600 TANK SEAT, WHITE, WITH COVER. PROVIDE 1/2" x 3/8" ANGLE STOP WITH OVAL HANDLE AND FLEXIBLE ADA COMPLIANT) RISERS. PROVIDE WITH MANUFACTURER'S PRESSURE ASSISTED FLUSHING SYSTEM. MOUNT PER ADA; TRIP LEVER ON WIDE SIDE. 1.6 GPF. WC-3 WATER CLOSET- PUBLIC PROFLO GILPIN ELONGATED - 3" 2" 1/2" - VITREOUS CHINA; FLOOR MOUNTED. PROVIDE VITREOUS CHINA TANK AND TANK COVER, POLISHED (PRESSURE ASSISTED PF1603PAWH WITH BOWL CHROME TRIP LEVER, BOLT CAPS, CLOSET SWEEP, SEAT FLANGE AND GASKET. CLOSED FRONT TANK TYPE, PF1600 TANK SEAT, WHITE, WITHOUT COVER. PROVIDE 1/2" x 3/8" ANGLE STOP WITH OVAL HANDLE AND FLEXIBLE ADA COMPLIANT) RISERS. PROVIDE WITH MANUFACTURER'S PRESSURE ASSISTED FLUSHING SYSTEM. MOUNT PER ADA; TRIP LEVER ON WIDE SIDE. 1.6 GPF. WCO-1 WALL CLEANOUT JAY R. SMITH - - - - - TAPERED BRONZE PLUG AND STAINLESS STEEL COVER. SIZE TO MATCH WASTE PIPING, 2" 4472 MINIMUM. NOTES: 1. FIXTURES INDICATED AS ADA MUST COMPLY WITH ICC/ANSI A117.1. VERIFY EXACT NUMBERS, FIXTURES, DESIGNATIONS, LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS WITH ARCHITECTURAL PLANS. 2. ALL HW PIPING AND DRAIN LINES BENEATH ADA COMPLIANT LAVATORIES MUST BE INSULATED TO PREVENT BURNS. REF ARCHITECTURAL PLANS. INSULATE WITH MOLDED CLOSED CELL VINYL INSULATION - TRUEBRO OR EQUAL. 3. ALL ACCESS PANELS AND WALL BOXES SHALL BE RATED TO MATCH ASSEMBLY RATING. 4. REFER TO KITCHEN EQUIPMENT SUPPLIER PLANS FOR COMMERICAL KITCHEN FIXTURES AND FLOW RATES. EQUIVALENT MANUFACTURERS: ENAMEL CAST IRON, VITREOUS CHINA, ACRYLIC: KOHLER, AMERICAN STANDARD, ELJER, CRANE, ZURN WARE, BEST BATH,LASCO, AQUAGLASS STAINLESS STEEL SINKS: ELKAY, JUST, DAYTON, KOHLER SERVICE SINKS: FIAT, BRADLEY, ACORN, STERN & WILLIAMS, E.L. MUSTEE FAUCETS: DELTA HDF, ELKAY, JUST, KOHLER, ZURN, AMERICAN STANDARD SHOWER VALVES, MIXING VALVES: POWERS, LEONARD, SYMMONS, MOEN TOILET SEATS: CHURCH, OSLONITE, BEMIS, SMITH ROOF DRAINS, FLOOR SINKS, FLOOR DRAINS, AND TRAPS: WATTS, ZURN, WADE, JOSAM WATTS BACKFLOW PREVENTION DEVICES, PRESSURE REDUCING VALVES: WILKENS, FEBCO, APOLLO/CONBRA CO TRAP PRIMERS AND SHOCK ABSORBERS: PPP, SIOUX CHEIF, SMITH GAS FIRED WATER HEATER SCHEDULE EQUIPMENT VOLUME NO. MANUFACTURER MODEL TYPE (GAL) WH-1, 2,3 AO SMITH BTH-199 DIRECT VENT, SEALED 100 COMBUSTION RECOVERY (GPH) FUEL 336 @ 70°F NATURAL RISE GAS ALTERNATE MANUFACTURERS: BRADFORD WHITE, RHEEM/RUDD, STATE, LOCHINVAR NOTES: 1. PROVIDE WITH 10 YEAR WARRANTY AND 1 YEAR PARTS WARRANTY. 2. SIZE INTAKE AND EXHAUST PER MANUFACTURER'S RECOMMENDATIONS. INPUT OUTPUT FLUE (MBH) (MBH) SIZE 199.9 193.9 (2) 3" PVC VOLT/PH/CY WEIGHT NOTES _ 120-1-60 1400 LBS PROVIDE COMPLETE WATER HEATER FOR SEALED VERTICAL DIRECT VENT OPERATION INCLUDING PIPING, MANUFACTURERS DIRECT VENT CONCENTRIC TERMINATION KIT, CNS-6 CONDENSATE NEUTRALIZATION KIT, AND 5 YEAR WARRANTY. PUMP SCHEDULE FLOW INLET DISCH ELECTRIC EQUIPMENT PUMP RATE HEAD SIZE SIZE IMPELLER NO. AREA SERVED LOCATION STYLE/CONST. FLUID TYPE RPM (GPM) (FT) (INCH) (INCH) DIA (INCH) HP VOLT.-PH.-CY. WEIGHT MANUFACTURER MODEL NOTES CPA, 2 HW RECIRC BOILER RM IN -LINE HOT WATER 1725 60 28 3" 3" -- 1.0 115-1-60 138 LBS B&G PD38 PROPORTIONAL PRESSURE CONTROL CIRCULATING PUMP. MOTOR SHALL BE PERMANENTLY LUBRICATED, REILIENT MOUNTED, FURNISH WITH CHECK VALVE, AQUASTAT AND TIMER. SPA ELEV. PIT ELEV. PIT SUMP WATER -- 50 20 2" 2" -- 0.4 115-1-60 10 LBS ZOELLER 940-0012 SUMP PUMP OIL GUARD SYSTEM, SIMPLEX, DUPLEX ALTERNATING PANEL. SP-2 PARKING PARKING SUMP - 41 GAL SOI WATER -- 50 15 4" 2" -- 0.4 115-1-60 60 LBS LIBERTY PUMPS LE40 SUMP PUMP. PROVIDE ALL ACCESSORIES INCLUDING DRAINAGE GARAGE ALARM, FOR A FULL INSTALLATION SP-3 PARKING LEVEL PARKING SUMP - 41 GAL SAN. WASTE -- 50 15 4" 2" -- 0.4 115-1-60 60 LBS LIBERTY PUMPS P372LE41 INTEGRAL SUMP PIT/PUMP. PROVIDE ALL ACCESSORIES FIXTURES GARAGE INCLUDING ALARM, FOR A FULL INSTALLATION SP-4 STORM WATER PARKING SUB. SUMP STORM WATER -- 20 10 1-1/2" 1-1/2" -- 0.25 115-1-60 60 LBS LIBERTY PUMPS 240 SERIES SUMP PUMP. PROVIDE ALL ACCESSORIES INCLUDING GARAGE ALARM, FOR A FULL INSTALLATION ALTERNATE MANUFACTURERS: GRUNDFOS, TACO NOTES: 1. PROVIDE ALL ANCILLARY COMPONENTS REQUIRED FOR A FULL INSTALLATION. MISCELLANEOUS PLUMBING EQUIPMENT SCHEDULE EQUIPMENT NO. DESCRIPTION MANUFACTURER MODEL NOTES ET-1 EXPANSION TANK AMTROL ST-42V 20 GALLON THERMAL EXPANSION TANK, 11.4 GALLON ACCEPTANCE VOLUME. FURNISH WITH ISOLATION VALVE AND DRAIN VALVE. MV-1 MIXING VALVE POWERS INTELLISTATION INTELLISTATION DIGITAL WATER TEMPERING AND RECIRCULATING SYSTEM. LFIS200 C O F OWA Sk �/ v I�, \ 41741 GISTER��\� FSS/oNAL � 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. w w Ur. dce ngin e ering. n e t Phone:208.288.2181 Project:21 AMA01 Q0 N O 00 O') p Z z O = Q W C 0 O O0 z O > > 10 J Q J _� O � O N I` z m F_ C:)LLI Z o U Q LU N U a REVISION DATE REASON FOR ISSUE C 02-08-22 CITY COMMENTS #03 D 01-07-22 SITE DEV. COMMENTS 5 03-25-22 RFI#20 11 06-07-22 RFI#27/CCD#2 13 06-27-22 RFI#41 PLUMBING SCHEDULES CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 SHEET NUMBER P5.0 f 0 D 0 L Single Valve IntelliStation 331/4" [844mm] - 201/8" [511 mm] � n Mixed Water Outlet Return [86mm] 1 MIXING VALVE DETAIL SCALE: NTS [301 mm] [210mm] 2 3 1 1 p p Q 44 Qn 4 44 Q 44 Q 4 p°aa n41a4oa4 2 6 3 O 6 aQ a� oa$'a4Q 44 COMPONENTS: 3 a4Q a ; Q a4p4a a4 1. EYE ROD 1 2. FLAT WASHER l-� \ COMPONENTS: 3. HEX HEAD CAP 1 rQOMPONENTS: 1. DROP IN ANCHO SCREW 2 CLIP 2. SPRING CLIP 4. ADJUSTABLE 4 (CEILING FLANGEZz. CEILING PLATE HANGER RING - COMPONENTS: 2. HEX NUT (OPTIONAL) 5. DROP IN 1. C-CLAMP 2. SETSCREW ]� 3. WOOD SCREW 4. HANGER ROD 3. HANGER ROD ANCHOR 6. HEX HEAD LAG 5 3. LOCK NUT 4 5. ADJUSTABLE 4. ADJUSTABLE HANGER RING 4 � SCREW 4. HANGER ROD HANGER RING 3 7. EXPANSHION 5. ADJUSTABLE CASE HANGER RING 5 8. LOCK WASHER 6. STEEL BEAM 4 in 9. HEX NUT OR BAR JOIST I STANDARD C-CLAMP PIPE HANGER CLIP PIPE HANGER CONCRETE PIPE HANGER FASTEN TO WOOD, CONCRETE, BLOCK, OR - STEEL WELD TO STEEL (OPTIONAL) 2 3 5 - 1 6 _ 5 3 1 \ 1 4 7 COMPONENTS: 1. POWDER -DRIVEN STUD COMPONENTS: h 1. WALL BRACKET 1 FOR WOOD FOR BRICK COMPONENTS: 2. ROD COUPLING ,_ 2 5 2 1 1. HEX NUT 2 3. HANGER ROD �-- I 2. HEX NUT 3. LOCK WASHER a 3 ? 3 \ 2. LOCK WASHER 3. HANGER ROD . 4ADJUSTABLE HANGER RING 4. FLAT WASHER 6 5. TRANSITION ROD 6. ROD COUPLING a�-� a o"� 9 3 ]� 4 4. ADJUSTABLE HANGER RING 5. STEEL BEAM 3 I� I 7. HANGER ROD 7 8. ADJUSTABLE HANGER RING 1 �� '-�� 1 8 a a OR BAR JOIST 4 FOR CONCRETE FOR STEEL 8 0 BEAM PIPE HANGER STUD TYPE PIPE HANGER WALL BRACKET PIPE HANGER EYE ROD PIPE HANGER 3 PIPE HANGER DETAIL SCALE: NTS ET 1 DISCHARGE FULL SIZE TO FLOOR SINK (TYP) (TYP) 3 NOTES 1. PROVIDE ONE (1) 3" INTAKE AND ONE (1) 3" EXHAUST VENT FROM EACH WATER HEATER. SEE MANUFACTURER'S VENTING GUIDELINES. ROUTE AND COORDINATE FINAL THRU ROOF TERMINATION POINT AND ROOF PENETRATION WITH ARCHITECT AND ROOFING CONTRACTOR. UTILIZE CONCENTRIC VENT KIT. MAINTAIN MINIMUM EIGHT (8) FEET DISTANCE FROM VERTICAL WALLS AND MINIMUM CODE REQUIRED CLEARANCES. UTILIZE 45° ELBOWS. 2. RECIRCULATION FOR TEMPERED HOT WATER TO CONNECT TO SYSTEM IN EXACT SEQUENCE AND CONFIGURATION PER MIXING VALVE MANUFACTURER. 3. PROVIDE A.O. SMITH "CNS-6" NEUTRALIZING FILTER FOR ALL WATER HEATER CONDENSATE DRAINS. ROUTE TO FLOOR SINK. 4. PROVIDE ALL PIPING AND VALUING FOR THE OPTION OF A FUTURE 4TH WATER HEATER. 3/4" CW - - - 2" CW - - -- 3" CW -- - - - 4" CW - 24" I 4" HW (140°) 4" HW (140°) 3" HW (140°) 2" 0 - 4" HW (140°) --- -- 2" HW (140°) ---� PRV TYPICAL 0 v 24" HEAT TRAP 1 MV P6.1 1 Ul NG (7" WC) 1 NG (7" WC) I NG (7" WC) I I NG (7" WC) U U U U N CV (V (V P4 (TYP) FUTURE 4 WH 2H 3H 4 WATER HEATER 4 .1. P6.0 P6.0 (TYP) .1. T 3/4" (TYP) 7 BOILER ROOM PIPING & WATER HEATER INSTALLATION L SCALE: NTS 1-1/4" NG (7" W.C.) ADDITIONAL, 400 MBH 207' FROM METER FOR INTERIOR REGULATORS, PROVIDE VENTLESS GAS REGULATOR, IN ACCESSIBLE LOCATION (TYP-ALL). 3" CONCRETE HOUSEKEEPING PAD 1" HW (140°) 4" HW (120°) REDUCER AT EACH CONNECTION TO MIXING VALVE 4" WATER METER FOR FIRST THERMOMETER FLOOR - COMMERCIAL 1" 140°F HOT WATER COMMERCIAL 10 DISHWASHER AND COMMERCIAL LAUNDRY. 10 4" 120°F HOT WATER I 9CP 1 WATER METER FOR UPPER I1 FLOORS - RESIDENTS 1 ` REDUNDANT RECIRCULATION CIDPUMP BY-PASS ASSEMBLY P6.0 2 21 GPM 1-1/4" 120°F HOT WATER RETURN 1-1/4" HWR J1(D \_111 BALL VALVE 3/4" NG (2 PSI) 3/4" N G (2 PSI) U U OUTDOOR 100' FROM 126' FROM FIREPLACE, UH-1, METER C METER C 40 MBH, 33 MBH, z z 6' FROM REG 3' FROM REG - O O O O U U � N CO MAU-1, DOAS-1, z 00 225 MBH, 133 MBH, CD CD 104' FROM z M 3' FROM REG 3' FROM REG z z METER Cl) v v M M 3/4" NG (2 PSI) 3/4" NG (2 PSI) 3/4" NG (2 PSI) [73 MBH] 1-1/2" NG (7" W.C.) 84' FROM METER [1,093 MBH] 1" NG (2 PSI) 1" NG (2 PSI; [1,093 MBH] [1,112 MBH] N.O. NOS 4" COLD WATER TO BUILDING. RPB-1 4-I%FIhD4'I 1 5" P6.0 5" WATER SERVICE FROM UTILITY U U U U U ' a PROVIDE ACCESSIBLE - - - EMERGENCY GAS PRESSURE MANUAL SHUT-OFF VALVE - C SHUT-OFF REGULATOR TO REGULATE UPSTREAM OF ANY GAS C7 VALVE GAS PRESSURE FROM TO 2 C7 REGULATOR (TYP-ALL) z z z z z z z z PSI TO 7" WC (TYP-ALL) z T 95 FROM METER M M M M r T 1-1/4" NG (7" W.C.) 1" NG (2 PSI) (PI 1-1/2" NG (7" W.C.) [971 MBH] � [796 MBH] FRYER, RANGE, CHARBROILER, CONVECTION CONVECTION 3/4" NG (2 PSI) U U U U 90 MBH 307 MBH 72 MBH STEAMER, OVEN, BASIS OF DESIGN: 77' FROM b 25' FROM REG 22' FROM REG 16' FROM REG 70 MBH 100 MBH 2O18 IFGC SECTION 402.4 -. METER 3/4" NG (2 PSI) 13' FROM REG 10' FROM REG TABLE 402.4(2) PRESSURE LESS THAN 2 PSI U TABLE 402.4(5) 2 PSI PRESSURE v z z z z C7 C7 z v v CONTRACTOR TO VERIFY EXACT GAS INPUT FOR z N M M i M i M M ALL APPLIANCES AND EQUIPMENT WITH OWNERS 7 _L PROVIDE FULL BORE REPRESENTATIVE PRIOR TO ANY PIPING. NOTIFY i O GAS SHUT-OFF ENGINEER WITH ANY DISCREPANCIES FUTURE DRYER, WATER WH-3, WH-2, W H-1, 175 MBH, HEATER, 199 MBH 199 MBH 199 MBH, GAS METER BY 5' FROM REG 199 MBH 23' FROM REG OTHERS, SIZED FOR 1-1/2" NG (2 PSI) 2,441 MBH @ 207'-0" [2,441 MBH] 4 GAS PIPING SCHEMATIC SCALE: NITS 41741 oONA� L 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. = ��A ao$�� DC ENGINEERING Careful listening. Dynamic solutions. www.drengineering.net Phone:208.288.2181 Project:21AMA01 (D CV O 00 CY) p 0 Z z 0 = Q 0 W o LL o 0 0 0 Z O ; > J Q J 0 -0 Of O N 0 I` Z m F_ p W Z N U) Q LU Q (�I U a REVISION DATE REASON FOR ISSUE 4 01-03-22 ADDENDUM #03 A 08-20-21 CITY COMMENTS #01 12 06-20-22 RFI#46 PLUMBING DETAILS CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 S MBER P6.1 PLUMBING GENERAL NOTES: CERTAIN EQUIPMENT REQUIREMENTS NOTED ON THESE DRAWINGS WERE DERIVED FROM OWNER -FURNISHED COORDINATION DRAWINGS. CONTRACTOR TO VERIFY ACTUAL OWNER -FURNISHED EQUIPMENT CONNECTION REQUIREMENTS AND SCOPE OF WORK. CONTRACTOR TO PROVIDE INSTALLATION OF ALL OWNER SUPPLIED PLUMBING FIXTURES. CONTRACTOR TO FIELD VERIFY LOCATION OF EXISTING SANITARY, DOMESTIC, AND GAS LINES. VERIFY AVAILABLE INVERT DEPTHS PRIOR TO BEGINNING WORK. CONTRACTOR TO VERIFY INVERTS OF MANHOLES AND DOCUMENT WHETHER BACKCHECK VALVE IS REQUIRED. PROVIDE ISOLATION VALVES ON ALL PLUMBING FIXTURES AND EQUIPMENT FOR SERVICE. PROVIDE CLEANOUTS ON ALL BRANCH PIPING OVER 8' IN LENGTH AND CHANGES IN DIRECTION OF 135° OR MORE. DOMESTIC PLUMBING MAINS TO BE COPPER IF OVER 2". PROVIDE 8' SUDS RELIEF OFFSET ON SUD PRODUCING RISERS. SEE SHEET P6.2 FOR DETAIL. ROUTE PLUMBING AS CLOSE TO THE PARKING CEILING AS POSSIBLE. SLOPE AT 1/4" PER FOOT. PLUMBING CONTRACTOR HAS THE OPTION TO WET VENT RESTROOM GROUPS, OR MODIFY STACK PLUMBING SYSTEM. THE ALTERNATE PLUMBING DESIGN MUST COMPLY WITH THE 2018 UPC �O �F WAS�J�/ 41741 /0 A N L 06/29/2022 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. DC ENGINEERING Careful listening. Dynamic solutions. www. dcengineerinn. net Phone:208.288.2181 Project:21 AMA01 N O 00 0') O Z z O= Q 0 W Cn 0 LL 0 O 0 LLI 3: z > > 10 J Q J O - O (N i Z m I- C:) LLJ Z o U LU Q\ N U a REVISION DATE REASON FOR ISSUE A 08-20-21 CITY COMMENTS #01 15 06-29-22 RFI#45 PLUMBING RISER DIAGRAMS CONSTRUCTION SET DATE PROJECT NUMBER 05.21.21 184470 SHEET NUMBER P6.3