Loading...
REVIEWED BLD2024-0191+Energy_Calculations+1.9.2024_4.09.21_PM+3991469BLD2024-0191 n RECEIVED Feb 13 2024 I his heating system sizing calculator IS based on the Hrescriptive Requirements or the 2ulb Washington State Energy code (WSEU) . I his tool Will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. This tool is for the permitting purposes only. A Manual J calculation is required to meet the requirement of the 2018 Washington State Energy Code. ITESTROET RESIDENCE ADDTION & REMODEL I KIT NEWMAN- ARCHITECT760OLLC 112D 22ND AVE. SEATTLE WA 98122 206 605-3277 arChitect760011c@gmail.com Heating System Type: DUCTED HEAT PUMP To see detailed instructions for each section, place your cursor on the word 'Instructions" Design Temperature Deisgn Temperature 29 Instructions SEATTLE Design Temperature Difference (AT) 41 AT = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 1,213 Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions Select U-Factor Skylights Instructions Insulation Attic Instructions R-49 Single Rafter or Joist Vaulted Ceilings Instructions R-49 Above Grade Walls (see Figure 1) Instructions I R-21 Floors Instructions R-30 Below Grade Walls and Slabs (see Figure 1) Instructions Wall & Slab Select Wall & Slab Insulation Depth Select nearest slab depth Slab on Grade (see Figure 1) Instructions R-10 Location of Ducts Instructions CONDITIONED SPACE Figure 1. Above Grade 1 Conditioned Volume 8.5 10,311 U-Factor X Area = UA 0.300 88.20 U-Factor X Area = UA 0.50 24 12.00 U-Factor X Area = UA 0.020 890 17.80 U-Factor X Area UA 0.020 323 6.46 U-Factor X Area UA 0.047 0.00 U-Factor X Area UA 0.033 1,023 33.74 Wall U-Factoi X Area UA No Selection Slab F-Factoi X Length UA F-Factor X Length UA 0.360 56 20.16 Duct Leakage Coefficient 1.000 Sum of UA 178.36 Envelope Heat Load 7,313 Btu / Hour Sum of UA x AT Air Leakage Heat Load 4,565 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 11,878 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 11,878 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 14,847 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace BY CITY OF EE BUILDING DEI (07/01/13)