REVIEWED BLD2024-0191+Structural_Calculations+1.9.2024_4.09.04_PM+3991468RECEIVED Feb 13 2024 Structural Calculations Testroet - Edmonds Residence 915 Maple St Edmonds, WA 98020 Project # x23-0801 12/17/2023 Prepared by Christopher Shaw PE Design and Creative PLLC (206) 428-7550 PO Box 28598 Seattle, WA 98118 BLD2024-0191 ................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT USGS web services were down for some period of time and as a result this tool wasn't operational, resulting in timeout error. USGS web services are now operational so this tool should work as expected. 915 Maple St, Edmonds, WA 98020, USA Latitude, Longitude: 47.8091357,-122.3662558 ®Salt and Iron Frances Anderson Center Edmonds 19 19 19 onds Edmonds Library Driftwo ayers Maple St D Maple St Alder St Alder St e Walnut Street Coffee t I Walnut St OSH PD Bell St Main St . 4 v_ Yost Pool Yost Park Tennis _arid Pickleball Courts l__4 - - - -1 , Goo9Ie Holly Dr Cedar St Map data 02023 Date 12/8/2023, 9:17:06 AM Design Code Reference Document ASCE7-16 Risk Category II Site Class D - Default (See Section 11.4.3) Type Value Description Ss 1.286 MCER ground motion. (for 0.2 second period) S1 0.452 MCER ground motion. (for 1.0s period) SMS 1.543 Site -modified spectral acceleration value SM1 null -See Section 11.4.8 Site -modified spectral acceleration value SDS 1.028 Numeric seismic design value at 0.2 second SA SD1 null -See Section 11.4.8 Numeric seismic design value at 1.0 second SA Type Value Description SDC null -See Section 11.4.8 Seismic design category Fa 1.2 Site amplification factor at 0.2 second Fv null -See Section 11.4.8 Site amplification factor at 1.0 second PGA 0.547 MCEG peak ground acceleration FPGA 1.2 Site amplification factor at PGA PGAM 0.656 Site modified peak ground acceleration TL 6 Long -period transition period in seconds SsRT 1.286 Probabilistic risk -targeted ground motion. (0.2 second) SsLlH 1.413 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration SsD 2.193 Factored deterministic acceleration value. (0.2 second) S1 RT 0.452 Probabilistic risk -targeted ground motion. (1.0 second) S1 UH 0.505 Factored uniform -hazard (2% probability of exceedance in 50 years) spectral acceleration. S1 D 0.892 Factored deterministic acceleration value. (1.0 second) PGAd 0.773 Factored deterministic acceleration value. (Peak Ground Acceleration) Project# x23-0801 Page 1 of 26 Type Value Description PGAUH 0.547 Uniform -hazard (2% probability of exceedance in 50 years) Peak Ground Acceleration CRS 0.91 Mapped value of the risk coefficient at short periods CR1 0.895 Mapped value of the risk coefficient at a period of 1 s Cv 1.357 Vertical coefficient Project# x23-0801 Page 2 of 26 Project: Testroet-Edmonds author: c.shaw Version: 4/1/2022 Date:12/13/2023 Project # x23-0801 Lateral Loads 52980 Total Seismic Design Force Per Equivalent Lateral Force Procedure ASCE 7-16 12.6 Cs = SoS/(R/le) = 0.158 Seismic Base Shear = Story Shear Forces Level 1 h = Csm = 0.03477 8379 1 b See attached for horizontal distribution at wall lines CXv FX 0.7pE 9.5 1 8379 7625 Project# x23-0801 Page 3 of 26 Wind Mean roof height, h = 15 Least horizontal dimension, W = 50.5 Envelope Method Allowed 51 Wind loads per ASCE 7-16 Basic Wind Speed = 98 mph Wind Exposure = B Surface Roughness = B Kzt = 1.00 26.8.2 Kd = 0.85 26.6 Kz = 0.7 28.3.1 Building Type: Enclosed Gcpi = +/- 0.18 Roof Pitch = 12 :12 q = 0.00256KZKZtKdV2 = 14.6288 Transverse Direction a = 3 ft 5.05 6 20.2 3 ft 5.1 6 20.4 Level 1 Zone Ps30 Kzt Area Wind Force (lb) A 21.6 1.00 1.00 47 1015.2 B 14.8 1.00 1.00 0 0 C 17.2 1.00 1.00 315 5418 D 11.8 1.00 1.00 0 0 6433.2 lb 5792lb Min 6433.2 Total (lb) Longitudinal Direction a = 3 ft 6.4 9.2 25.6 Oft 5.1 6 20.4 Level 1 Zone Ps30 Kzt A Area Wind Force (lb) A 21.6 1.00 1.00 31 669.6 B 14.8 1.00 1.00 60 888 C 17.2 1.00 1.00 160 2752 D 11.8 1.00 1.00 172 2029.6 6339.2 lb 4912 lb Min 4912 Total (lb) Project# x23-0801 Page 4 of 26 Lateral Load Summary Trans 0.7pE 7625 <— Controls 0.6W 3860 -- Long 0.7pE 7625 <— Controls 0.6W 3804 - - Project# x23-0801 Page 5 of 26 ME 0 An r O Z cTRANSVERSE 0 z D r t1=o.s�/ =3��Z40 0, 1144 #(to S-71 0&) FIRST FLOOR WALLS & ROOF FRAMING ABOVE DO NOT SCNEREFER TO ARCH VOFDMENSMS LATERAL LOAD DISTRIBUTION Project# x23-0801 Page 6 of 26 Project: Testroet-Edmonds author: c.shaw Version: 7/31/2023 Date:12/13/2023 Level 1 Wall Line SHEAR FROM ABOVE _ UPLIFT FROM ABOVE _ 1 Shearwall Calculation 0lb (E) WALL DEAD LOADS 0lb (W) 0lb (E) 0lb (W) WIDTH TYPE PSF 0.6D (lb) 8 ROOF 15 72 SHEAR @ DIAPHRAGM LEVEL = 1144 lb (E) 8 WALL 10 48 579lb (W) 0 FLOOR 12 0 TOTAL: 120 WALL HEIGHT = 8 ft TOTAL LENGHT OF WALL = 5 ft MIN PANEL WIDTH = 2.5ft ASPECT RATIO = 3.20 ASPECT RATIO INCREASE = 1.60 1.60 (SDPWS 4.3.4.1) FLOW SHEAR = 228.80 plf (E) 115.80 plf (W) SHEATHING SHEAR = 366.08 plf (E) 115.80 plf (W) WALL MOMENTS MovT = 4576.0 ft-lb (E) 2316.0 ft-lb (W) M RES = 375.0 ft-lb UPLIFT= 1680.4lb (E) 776.4lb (W) HOLDOWN: STHD14 Project# x23-0801 Page 7 of 26 Project: Testroet-Edmonds author: c.shaw Version: 7/31/2023 Date:12/13/2023 Level 1 Wall Line SHEAR FROM ABOVE _ UPLIFT FROM ABOVE _ SHEAR @ DIAPHRAGM LEVEL = WALL HEIGHT = TOTAL LENGHT OF WALL = MIN PANEL WIDTH = ASPECT RATIO = ASPECT RATIO INCREASE _ (SDPWS 4.3.4.1) FLOW SHEAR = SHEATHING SHEAR = WALL MOMENTS 2 Shearwall Calculation 0lb (E) WALL DEAD LOADS 0lb (W) 0lb (E) 0lb (W) WIDTH TYPE PSF 0.6D (Ib) 3.333 ROOF 15 29.997 839lb (E) 8 WALL 10 48 425lb (W) 0 FLOOR 12 0 TOTAL: 77.997 8 ft 11.66 ft 5.66 ft 1.41 1.00 0.71 71.96 plf (E) 36.45 plf (W) 71.96 plf (E) 36.45 plf (W) MovT = 3258.1 ft-Ib (E) 1650.4 ft-Ib (W) M RES = 1249.3 ft-Ib UPLIFT= 354.9lb (E) 70.9 lb (W) HOLDOWN: None Re Project# x23-0801 Page 8 of 26 Project: Testroet-Edmonds author: c.shaw Version: 7/31/2023 Date:12/13/2023 Level 1 Wall Line SHEAR FROM ABOVE _ UPLIFT FROM ABOVE _ 3 Shearwall Calculation 0lb (E) WALL DEAD LOADS 0lb (W) 0lb (E) 0lb (W) WIDTH TYPE PSF 0.6D (lb) 3.333 ROOF 15 29.997 SHEAR @ DIAPHRAGM LEVEL = 3812 lb (E) 8 WALL 10 48 1930lb (W) 0 FLOOR 12 0 TOTAL: 77.997 WALL HEIGHT = 8 ft TOTAL LENGHT OF WALL = 24.25 ft MIN PANEL WIDTH = 3ft ASPECT RATIO = 2.67 ASPECT RATIO INCREASE = 1.33 1.33 (SDPWS 4.3.4.1) FLOW SHEAR = 157.20 plf (E) 79.59 plf (W) SHEATHING SHEAR = 209.59 plf (E) 79.59 plf (W) WALL MOMENTS MovT = 3772.7 ft-lb (E) 1910.1 ft-lb (W) M RES = 351.0 ft-lb UPLIFT= 1140.6lb (E) 519.7 Ib (W) HOLDOWN: HDU11 Project# x23-0801 Page 9 of 26 Project: Testroet-Edmonds author: c.shaw Version: 7/31/2023 Date:12/13/2023 Level 1 Wall Line B Shearwall Calculation SHEAR FROM ABOVE = 0lb (E) WALL DEAD LOADS 0lb (W) UPLIFT FROM ABOVE = 0lb (E) 0lb (W) WIDTH TYPE PSF 0.6D (lb) 3.333 ROOF 15 29.997 SHEAR @ DIAPHRAGM LEVEL = 419.5 Ib (E) 8 WALL 10 48 425lb (W) 0 FLOOR 12 0 TOTAL: 77.997 WALL HEIGHT = 8 ft TOTAL LENGHT OF WALL = 3.5 ft MIN PANEL WIDTH = 3.5ft ASPECT RATIO = 2.29 ASPECT RATIO INCREASE = 1.14 1.14 (SDPWS 4.3.4.1) FLOW SHEAR = 119.86 plf (E) 121.43 plf (W) SHEATHING SHEAR = 136.98 plf (E) 121.43 plf (W) WALL MOMENTS MovT = 3356.0 ft-lb (E) 3400.0 ft-lb (W) M RES = 477.7 ft-lb UPLIFT= 822.4lb (E) 834.91b (W) HOLDOWN: None Re Project# x23-0801 Page 10 of 26 Project: Testroet-Edmonds author: c.shaw Version: 7/31/2023 Date:12/13/2023 Level 1 Wall Line D Shearwall Calculation SHEAR FROM ABOVE = 0lb (E) WALL DEAD LOADS 0lb (W) UPLIFT FROM ABOVE = 0lb (E) 0lb (W) WIDTH TYPE PSF 0.6D (lb) 2 ROOF 15 18 SHEAR @ DIAPHRAGM LEVEL = 3812 lb (E) 8 WALL 10 48 1902lb (W) 0 FLOOR 12 0 TOTAL: 66 WALL HEIGHT = 9 ft TOTAL LENGHT OF WALL = 14.75 ft MIN PANEL WIDTH = 3ft ASPECT RATIO = 3.00 ASPECT RATIO INCREASE = 1.50 1.50 (SDPWS 4.3.4.1) FLOW SHEAR = 258.44 plf (E) 128.95 plf (W) SHEATHING SHEAR = 387.66 plf (E) 128.95 plf (W) WALL MOMENTS MovT = 6977.9 ft-lb (E) 3481.6 ft-lb (W) M RES = 297.0 ft-lb UPLIFT= 2227.0lb (E) 1061.5lb (W) HOLDOWN: HTT5 Project# x23-0801 Page 11 of 26 Project: Testroet-Edmonds author: c.shaw Version: 7/31/2023 Date:12/13/2023 Level 1 Wall Line SHEAR FROM ABOVE _ UPLIFT FROM ABOVE _ SHEAR @ DIAPHRAGM LEVEL = WALL HEIGHT = TOTAL LENGHT OF WALL = MIN PANEL WIDTH = ASPECT RATIO = ASPECT RATIO INCREASE _ (SDPWS 4.3.4.1) FLOW SHEAR = SHEATHING SHEAR = WALL MOMENTS E Shearwall Calculation 0lb (E) WALL DEAD LOADS 0lb (W) 0lb (E) 0lb (W) WIDTH TYPE PSF 0.6D (Ib) 2 ROOF 15 18 1144lb (E) 8 WALL 10 48 571 lb (W) 0 FLOOR 12 0 TOTAL: 66 9 ft 17 ft 17 ft 0.53 1.00 0.26 67.29 plf (E) 33.59 plf (W) 67.29 plf (E) 33.59 plf (W) MovT = 10296.0 ft-Ib (E) 5139.0 ft-Ib (W) M RES = 9537.0 ft-Ib UPLIFT= 44.61b (E) -258.7lb (W) HOLDOWN: None Re Project# x23-0801 Page 12 of 26 Sheet1 author: c.shaw Version: 12/10/2018 SHEARWALL SUMMARY Flow Shear (plf) Sheathing Wall Line of Shear (plf) vs Uplift(lb) Holdown I SW Type 7 2Z 2 �0 Page 1 s-r�Auq µ-is Project# x23-0801 Page 13 of 26 F O R T E W E B' JOB SUMMARY REPORT Testroet New Beams x23-0801 Level Member Name Results Current Solution Comments 0-0 Floor: Joist HOT TUB Passed 1 piece(s) 2 x 8 HF No.2 @ 12" OC 0-0.1 Floor: Joist Passed 1 piece(s) 2 x 8 DF No.2 @ 16" OC 0-1 Floor: Flush Beam Passed 1 piece(s) 4 x 10 HF No.2 0-0.1 Floor: Joist TYPICAL DECK Passed 1 piece(s) 2 x 8 HF No.2 @ 16" OC 0-2 Floor: Flush Beam Passed 1 piece(s) 4 x 10 HF No.2 0-1 Floor: Flush Beam HOT TUB Passed 1 piece(s) 4 x 12 HF No.2 1-0 Roof: Joist Passed 1 piece(s) 2 x 12 DF No.2 @ 16" OC 1-1 Roof: Flush Beam Passed 1 piece(s) 4 x 10 DF No.2 1-2 Wall: Header Passed 2 piece(s) 2 x 6 HF No.2 1-3 Wall: Header Passed 2 piece(s) 2 x 8 HF No.2 1-6 Roof: Flush Beam Passed 1 piece(s) 3 1/2" x 11 1/4" 1.55E TimberStrand@ LSL ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6 Weyerhaeuser File Name: Testroet New _Beams x23-0801 Project# x23-0801 Page 14 of 26 Page 1 / 12 aFORTEWEB' Level, 0-0 Floor: Joist HOT TUB 1 piece(s) 2 x 8 HF No.2 @ 12" OC PASSED F i H All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 930 @ 1' 1 3/4" 2126 (3.50") Passed (44%) 1.0 D + 1.0 L (Adj Spans) Shear (Ibs) 512 @ 1' 10 3/4" 1088 Passed (47%) 1.00 1.0 D + 1.0 L (Adj Spans) Moment (Ft-Ibs) 963 @ 4' 1 1/2" 1284 Passed (75%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.092 @ 4' 1 1/2" 0.149 Passed (L/781) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.099 @ 4' 1 1/2" 0.298 Passed (L/721) 1.0 D + 1.0 L (Alt Spans) TJ-ProT"' Rating N/A N/A N/A N/A • Deflection criteria: LL (L/480) and TL (L/240). • Overhang deflection criteria: LL (2L/480) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on Nos. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Factored 1 - Stud wall - HF 3.50" 3.50" 1.53" 82 847 105 930 Blocking 2 - Stud wall - HF 3.50" 3.50" 1.53" 82 847 105 930 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' 9" o/c Bottom Edge (Lu) 8' 3" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.g0) Floor Live (1.00) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 8' 3" 12" 20.0 200.0 25.0 Deck HOT TUB System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 15 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 2 / 12 aFORTEWEB' Level, 0-0.1 Floor: Joist 1 piece(s) 2 x 8 DF No.2 @ 16" OC PASSED J 51 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 279 @ 2 1/2" 1215 (2.00") Passed (23%) 1.0 D + 1.0 L (All Spans) Shear (Ibs) 220 @ 10 3/4" 1305 Passed (17%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 488 @ T 9 1/2" 1360 Passed (36%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.042 @ 3' 9 1/2" 0.179 Passed (L/999+) 1.0 D + 1.0 L (All Spans) Total Load Defl. (in) 0.059 @ 3' 9 1/2" 0.358 Passed (L/999+) 1.0 D + 1.0 L (All Spans) TJ-ProT"' Rating N/A N/A N/A N/A • Deflection criteria: LL (L/480) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on Nos. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Factored 1 - Stud wall - HF 3.50" 2.00" 1.50" 86 202 288 1 1/2" Rim Board 2 - Stud wall - HF 3.50" 2.00" 1.50" 86 202 288 1 1/2" Rim Board • Kim uoam is assumea m carry an ioaas appueo aireary aoove a, Dypassmg me memoer Deing oesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' 4" o/c Bottom Edge (Lu) 7' 4" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Comments 1 - Uniform (PSF) 0 to 7' 7" 16" 17.0 40.0 Floor 0 System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 16 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 3 / 12 aFORTEWEB' Level, 0-1 Floor: Flush Beam 1 piece(s) 4 x 10 HF No.2 PASSED i 2' 5' 6' F 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1837 @ 7' 11 1/2" 2126 (1.50") Passed (86%) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Shear (Ibs) 1490 @ 3' 2 3/4" 3238 Passed (46%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 2455 @ 5' 2 1/2" 4242 Passed (58%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.039 @ 5' 1 7/16" 0.143 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.048 @ 5' 1 7/8" 0.286 Passed (L/999+) 1.0 D + 0.75 L + 0.75 S (Alt Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Overhang deflection criteria: LL (2L/480) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Bearing Length ■ Supports Total Available Required Loads to Supports (Ibs) Accessories Dead Floor Live Snow Factored 1 - Stud wall - HF 5.50" 5.50" 2.64" 930 2653 1105 3749 Blocking 2 - Hanger on 9 1/4" DF beam 3.50" Hangers 1.50" 456 1515/-68 588 1 2033 See note ' • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' o/c Bottom Edge (Lu) 8' o/c -Maximum allowable bracing intervals based on applied load. System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LUS410 2.00" N/A 8-16d 6-16d • Refer to manufacturer notes and instructions for proper installation and use of all connectors. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 7' 11 1/2" N/A 8.2 1 - Uniform (PSF) 0 to 8' 3" (Front) 8' 20.0 60.0 25.0 Deck Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 17 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 4 / 12 aFORTEWEB' Level, 0-0.1 Floor: Joist TYPICAL DECK 1 piece(s) 2 x 8 HF No.2 @ 16" OC PASSED PF L 1. 1 FI All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 486 @ 10' 10 1/2" 1215 (2.00") Passed (40%) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Shear (Ibs) 414 @ 2' 10 3/4" 1088 Passed (38%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) 986 @ 6' 6 15/16" 1284 Passed (77%) 1.00 1.0 D + 1.0 L (Alt Spans) Live Load Defl. (in) 0.175 @ 6' 6 1/4" 0.218 Passed (L/597) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Total Load Defl. (in) 0.224 @ 6' 6 1/2" 0.436 Passed (L/468) 1.0 D + 0.75 L + 0.75 S (Alt Spans) TJ-ProT"' Rating N/A N/A N/A N/A • Deflection criteria: LL (L/480) and TL (L/240). • Overhang deflection criteria: LL (2L/480) and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on Nos. • No composite action between deck and joist was considered in analysis. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Factored 1 - Beam - HF 3.50" 3.50" 1.50" 181 542 226 756 Blocking 2 - Stud wall - HF 3.50" 2.00" 1.50" 115 366/-11 148 500 1 1/2" Rim Board • Rim Board is assumed to carry all loads applied directly above it, bypassing the member being designed. • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) T Y o/c Bottom Edge (Lu) 11' o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Floor Live (1.00) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 11' 1" 16" 20.0 60.0 25.0 Deck 0 System : Floor Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Veyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties elated to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is esponsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Veyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-138-, nd/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to jww.weyerhaeuser.com/woodproducts/document-library. 'he product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM LTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 18 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 5 / 12 aFORTEWEB' Level, 0-2 Floor: Flush Beam 1 piece(s) 4 x 10 HF No.2 PASSED pr 2 t� Ifl J J All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1476 @ 6' 11 1/2" 2126 (1.50") Passed (69%) 1.0 D + 0.75 L + 0.75 S (Alt Spans) Shear (Ibs) 1225 @ 3' 2 3/4" 3238 Passed (38%) 1.00 1.0 D + 1.0 L (All Spans) Moment (Ft-Ibs) -1611 @ 2' 2 3/4" 4242 Passed (38%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.033 @ 0 0.200 Passed (2L/999+) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.035 @ 0 0.223 Passed (2L/999+) 1.0 D + 1.0 L (Alt Spans) • Deflection criteria: LL (L/480) and TL (L/240). • Overhang deflection criteria: LL (0.2") and TL (2L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. ■ Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Factored 1 - Stud wall - HF 5.50" 5.50" 2.45" 861 2457 1024 3472 Blocking 2 - Hanger on 9 1/4" DF beam 3.50" Hangers 1.50" 356 1275/-112 479 1671 See note ' • rswcKmg vaneis are assumed ro carry no ioacis appuea directly aoove mem and me Tuii ioad is appuea ro me memoer Deing designea. • At hanger supports, the Total Bearing dimension is equal to the width of the material that is supporting the hanger • 1 See Connector grid below for additional information and/or requirements. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 7' o/c Bottom Edge (Lu) 7' o/c -Maximum allowable bracing intervals based on applied load. 0 System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Connector: Simpson Strong -Tie Support Model Seat Length Top Fasteners Face Fasteners Member Fasteners Accessories 2 - Face Mount Hanger LUS410 2.00" N/A 8-10d 6-10d • Reter to manutacturer notes and instructions nor proper installation and use of all connectors. Vertical Loads Location (Side) Tributary Width Dead (0.90) Floor Live (1.00) Snow (1.1S) Comments 0 - Self Weight (PLF) 0 to 6' 11 1/2" N/A 8.2 1 - Uniform (PSF) 0 to 7' 3" (Front) 8' 20.0 60.0 25.0 Deck Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 19 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 6 / 12 aFORTEWEB' Level, 0-1 Floor: Flush Beam HOT TUB 1 piece(s) 4 x 12 HF No.2 PASSED b�➢ r i I 3' 4" ❑2 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 5017 @ 7' 3 1/4" 4961 (3.50") Passed (101%) 1.0 D + 1.0 L (Adj Spans) Shear (Ibs) 1960 @ 6' 2 1/4" 3938 Passed (50%) 1.00 1.0 D + 1.0 L (Adj Spans) Moment (Ft-Ibs) -4054 @ 7' 3 1/4" 5752 Passed (70%) 1.00 1.0 D + 1.0 L (All Spans) Live Load Defl. (in) 0.122 @ 10' 9" 0.232 Passed (2L/686) 1.0 D + 1.0 L (Alt Spans) Total Load Defl. (in) 0.129 @ 10' 9" 0.348 Passed (2L/648) 1.0 D + 1.0 L (Alt Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Overhang deflection criteria: LL (2L/360) and TL (2L/240). • Right cantilever length exceeds 1/3 member length or 1/2 back span length. Additional bracing should be considered. • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Floor Live Snow Factored 1 - Stud wall - HF 5.50" 5.50" 2.02" 236 2625 291 2861 Blocking 2 - Beam - DF 3.50" 3.50" 3.54" 516 4501 558 5017 Blocking • Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 10' 9" o/c Bottom Edge (Lu) 10' 9" o/c -Maximum allowable bracing intervals based on applied load. Dead Floor Live Snow Vertical Loads Location (Side) Tributary Width (0.90) (1.00) (1.15) Comments 0 - Self Weight (PLF) 0 to 10' 9" N/A 10.0 1 - Uniform (PSF) 0 to 10' 9" (Front) 3' 20.0 200.0 25.0 Deck @ HOT TUB System : Floor Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 20 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 7 / 12 aFORTEWEB' Level, 1-0 Roof: Joist 1 piece(s) 2 x 12 DF No.2 @ 16" OC PASSED + + 0 17 . b 1 a a All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 548 @ 2 1/2" 2231 (3.50") Passed (25%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 475 @ 1' 2 3/16" 2329 Passed (20%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 2330 @ 8' 11" 3138 Passed (74%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.269 @ 8' 11" 0.918 Passed (L/818) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.496 @ 8' 11" 1.224 Passed (L/444) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • A 15% increase in the moment capacity has been added to account for repetitive member usage. • Applicable calculations are based on Nos. Supports Bearing Length Loads to Supports (Ibs) Accessories Tntal Available Required Dead Snow Factored 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 251 297 548 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1.50" 251 297 548 Blocking • 1:51OcKmg vaneis are assumes ro carry no ioaas appuea airecny aoove mem ano me Tuu ioaa is appuea ro me memoer Demg Designeo. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) T 7" o/c Bottom Edge (Lu) 18' 10" o/c -Maximum allowable bracing intervals based on applied load. Vertical Load Location (Side) Spacing Dead (0.90) Snow (1.15) Comments 1 - Uniform (PSF) 0 to 17' 10" 16" 20.0 25.0 Roof + Solar Member Length : 19' 1 5/16" System : Roof Member Type : Joist Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 4/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 21 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 8 / 12 aFORTEWEB' Level, 1-1 Roof: Flush Beam 1 piece(s) 4 x 10 DF No.2 PASSED A79 I i 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1208 @ 2" 2835 (2.00") Passed (43%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1031 @ 1' 3/4" 4468 Passed (23%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 3824 @ 6' 6 1/2" 5166 Passed (74%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.161 @ 6' 6 1/2" 0.637 Passed (L/950) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.303 @ 6' 6 1/2" 0.850 Passed (L/505) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/240) and TL (L/180). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on Nos. Bearing Length Supports Available Required Loads to Supports (Ibs) Accessories Dead Snow Factored 1 - Stud wall - HF 3.50" 2.00" 1.50" 576 654 1230 1 1/2" Rim Board 2 - Stud wall - HF 3.50" 2.00" 1.50" 576 654 1230 1 1/2" Rim Board • Kim noara is assumea to carry all ioaas appirea airecay aoove it, Dypassing the memoer Deing aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 12' 10" o/c Bottom Edge (Lu) 12' 10" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 1 1/2" to 12' 11 1/2" N/A 8.2 1 - Uniform (PSF) 0 to IT 1" (Front) 4' 20.0 25.0 Roof + Solar 0 System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 0/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 22 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 9 / 12 .I FO RTE W E B MEMBER REPORT PASSED Level, 1-2 Wall: Header 2 piece(s) 2 x 6 HF No.2 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. H Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 703 @ 0 1823 (1.50") Passed (39%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 581 @ 7" 1898 Passed (31%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1186 @ T 4 1/2" 1602 Passed (74%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.086 @ 3' 4 1/2" 0.225 Passed (L/938) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.180 @ 3' 4 1/2" 0.313 Passed (L/450) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (5/16"). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 365 338 703 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 365 338 703 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 6' 9" o/c Bottom Edge (Lu) 6' 9" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 6' 9" N/A 4.2 1 - Uniform (PSF) 0 to 6' 9" 4' 20.0 25.0 Roof + Solar 2 - Uniform (PSF) 0 to 6' 9" 2' 12.0 - Wall System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 23 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 10 / 12 aFORTEWEB' Level, 1-3 Wall: Header 2 piece(s) 2 x 8 HF No.2 PASSED IV 0 All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. H Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 812 @ 0 1823 (1.50") Passed (45%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 676 @ 8 3/4" 2501 Passed (27%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 1775 @ 4' 4 1/2" 2569 Passed (69%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.106 @ 4' 4 1/2" 0.292 Passed (L/986) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 1 0.198 @ 4' 4 1/2" 0.313 Passed (L/532) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (5/16"). • Allowed moment does not reflect the adjustment for the beam stability factor. • Applicable calculations are based on NDS. Supports Bearing Length Loads to Supports (Ibs) Accessories Total Available Required Dead Snow Factored 1 - Trimmer - SPF 1.50" 1.50" 1.50" 374 437 812 None 2 - Trimmer - SPF 1.50" 1.50" 1 1.50" 374 437 812 None Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 8' 9" o/c Bottom Edge (Lu) 8' 9" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads am Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 8' 9" N/A 5.5 -- 1 - Uniform (PSF) 0 to 8' 9" 4' 20.0 25.0 Roof + Solar 0 System : Wall Member Type : Header Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Weyerhaeuser Notes Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 24 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 11 / 12 aFORTEWEB' Level, 1-6 Roof: Flush Beam 1 piece(s) 3 1/2" x 11 1/4" 1.55E TimberStrand@ LSL PASSED All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) Member Reaction (Ibs) 1784 @ 2" 5206 (3.50") Passed (34%) 1.0 D + 1.0 S (All Spans) Shear (Ibs) 1551 @ 1' 2 3/16" 9358 Passed (17%) 1.15 1.0 D + 1.0 S (All Spans) Moment (Ft-Ibs) 7770 @ 9' 1/2" 16548 Passed (47%) 1.15 1.0 D + 1.0 S (All Spans) Live Load Defl. (in) 0.400 @ 9' 1/2" 0.624 Passed (L/561) 1.0 D + 1.0 S (All Spans) Total Load Defl. (in) 0.790 @ 9' 1/2" 0.936 Passed (L/284) 1.0 D + 1.0 S (All Spans) • Deflection criteria: LL (L/360) and TL (L/240). • Allowed moment does not reflect the adjustment for the beam stability factor. • Resawn products must maintain manufacturing stamps. Bearing Length Supports Available Required Loads to Supports (Ibs) Accessories Dead Snow Factored 1 - Beveled Plate - SPF 3.50" 3.50" 1.50" 880 904 1784 Blocking 2 - Beveled Plate - SPF 3.50" 3.50" 1.50" 880 904 1784 Blocking • NOCKing Panels are assumea to carry no ioaas appuea airectiy aoove mem ana the tuu ioaa is appuea to the memoer Deing aesignea. Lateral Bracing Bracing Intervals Comments Top Edge (Lu) 19' 1" o/c Bottom Edge (Lu) 19' 1" o/c -Maximum allowable bracing intervals based on applied load. Vertical Loads ' Location (Side) Tributary Width Dead (0.90) Snow (1.15) Comments 0 - Self Weight (PLF) 0 to 18' 1" N/A 12.3 1 - Uniform (PSF) 0 to 18, 1" 4' 20.0 25.0 Roof + Solar 0 Member Length : 19' 4 1/2" System : Roof Member Type : Flush Beam Building Use : Residential Building Code : IBC 2015 Design Methodology : ASD Member Pitch : 4/12 Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at Weyerhaeuser facilities are third -party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/document-library. The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator ForteWEB Software Operator Job Notes Christopher Shaw Design and Creative PLLC (206) 428-7550 chriscshaw@gmail.com 12/18/2023 12:28:13 PM UTC ForteWEB v3.6, Engine: V8.3.1.5, Data: V8.1.4.1 Pr ,IeT x23 �801 P e 25 8f 26 Weyerhaeuser I e ame: estroet�ew _ eams_x23-0801 Page 12 / 12 Spread Footing Design 2018 IBC/ACI 318-14 Inputs Service Dead Load = 0.00 kips Service Live Load = 8.00 kips Factored Load = 12.80 kips Allowable Soil Bearing Stress = 2000 psf Concrete Strength (fc) = 2500 psi Column Xc Dimension = 5.50 in Column Yc Dimension = 5.50 in X Dimension = 2.00 ft Y Dimension = 2.00 ft Fy = 60.0 ksi Thickness (t) = 8.00 in Clear Cover = 3.00 in Depth (d) = 4.75 in Bearing Check Required Footing Area =4.00 sq. ft Actual Footing Area =4.00 sq. ft OK Beam Shear Desian - X Direction Ultimate Soil Bearing Stress = 3.20 ksf O= 0.75 Vu = 2 kips OVn = 9 kips OK 04 Flexural Desian - X Direction O= 0.9 Bar Size = #4 Number of Bars Provided = 3 As Minimum = 0.35 sq. in As Provided = 0.60 sq. in Mu = 2 ft-kips OMn = 12 ft-kips Bar Spacing = 9.00 in Beam Shear Design - Y Direction Flexural Design - Y Direction O= 0.75 O= 0.9 Vu = 2 kips Bar Size = #4 OW = 9 kips OK Number of Bars Provided = 3 As Minimum = 0.35 sq. in Punching Shear Design As Provided = 0.60 sq. in O= 0.75 Mu = 2 ft-kips Vu = 10 kips OMn = 12 ft-kips OW = 29 kips OK Bar Spacing = 9.00 in Y OK OK OK OK OK Project# x23-0801 Page 26 of 26