SEE REV1 APPROVED PLN ENG BLD RESUB 2-BLD2024-0191+Architectural_Plan+6.4.2024_5.16.19_PM+4301173ARCHITECTURAL NOTES GENERAL 1. ALL WORK SHALL CONFORM TO THE 2018 INTERNATIONAL RESIDENTIAL CODE, THE 2018 INTERNATIONAL BUILDING CODE, THE 2018 WASHINGTON STATE ENERGY CODE ( RESIDENTIAL), AND ALL APPLICABLE LOCAL JURISDICTION RULES AND REGULATIONS. 2. CONTRACTOR TO VERIFY ALL DIMENSION DATUMS AND LEVELS PRIOR TO CONSTRUCTION. ALL DIMENSIONS ARE TO FACE OF STUD OR FACE OF CONCRETE UNLESS NOTED OTHERWISE. DO NOT SCALE DRAWINGS FOR CRITICAL DIMENSIONS. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. 4. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN WITHOUT WRITTEN INSTRUCTIONS FROM THE ARCHITECT. 5. REPORT ERRORS AND/OR OMISSIONS ON THESE DRAWINGS TO THE ARCHITECT IMMEDIATELY. 6. THESE DRAWINGS ARE THE PROPERTY OF ARCHITECT7600 LLC AND MAY BE REPRODUCED ONLY WITH WRITTEN PERMISSION. AUTHORIZED REPRODUCTIONS MUST BEAR THE NAME, STAMP & SIGNATURE OF THE ARCHITECT. 7. WORKING DRAWINGS BY THEIR VERY NATURE ARE DIAGRAMMATIC AND DO NOT PROVIDE ALL DETAILS OR CONDITIONS OF CONSTRUCTION. HOWEVER, QUESTIONS MAY ARISE AS TO THE DESIGN INTENT, AND CONSTRUCTION TECHNICAL DETAILING WITHIN THESE DRAWINGS. AS CLARIFICATIONS, INTERPRETATIONS, AND REVISIONS ARE PART OF THE CONSTRUCTION PROCESS, ARCHITECT7600 LLC SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT OR CONSEQUENTIAL DAMAGES AS A RESULT OF NOT PARTICIPATING IN THE CONSTRUCTION PROCESS. MISCELLANEOUS ASSEMBLY REQUIREMENTS 1. ALL EXPOSED EXTERIOR METAL SHALL BE GALVANIZED. 2. ALL WOOD IN CONTACT WITH CONCRETE OR EARTH SHALL BE PRESSURE TREATED. ALL PRESSURE TREATED LUMBER (PT.) SHALL NOT CONTAIN, OR BE TREATED WITH CHROMIUM COPPER ARSENATE. 3. PROVIDE ATTIC ACCESS, MINIMUM 22" X 30", WITH 30" MINIMUM HEADROOM AT UNOBSTRUCTED, READILY ACCESSIBLE OPENING PER IRC R807. INSULATE AND WEATHER-STRIP. 4. PROVIDE CRAWL SPACE ACCESS, MINIMUM 18"X 24" UNOBSTRUCTED OPENING PER IRC R408.4. ALLOW 18" MINIMUM SPACE UNDER WOOD JOISTS AND 12" MINIMUM UNDER WOOD GIRDERS. INSULATE AND WEATHER-STRIP. 5. PROVIDE VENTILATION PER IRC AS FOLLOWS: a. CRAWL SPACE VENTILATION: MINIMUM NET AREA SHALL NOT BE LESS THAN 1 SF PER 150 SF OF UNDERFLOOR AREA. OPENINGS SHALL BE PLACED WITHIN 3 FEET OF THE CORNERS AND SHALL PROVIDE CROSS VENTILATION PER IRC R408.1 AND R408.2 b. ATTIC VENTILATION: MINIMUM NET AREA SHALL NOT BE LESS THAN 1 SF PER 150 SF OF ATTIC AREA, OR 1 SF PER 300 SF OF ATTIC AREA IF 50% IS IN THE SOFFIT AND 50% IS AT LEAST 3' ABOVE THE PLATE LINE PER IRC R806.2. 6. SLOPE ALL DECKS, WALKS, DRIVEWAYS AND PATIOS AWAY FROM THE BUILDING AT A MINIMUM OF 1/4" PER FOOT. 7. STAIR ASSEMBLY: a. HEADROOM 6-8" MIN. AND WIDTH 3'-0" MINI PER IRC R311.7.1 & R311.7.2 b. THE MAXIMUM RISER HEIGHT SHALL BE 7-3/4". OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENING BETWEEN TREADS IS LESS THAN 4". THE MINIMUM TREAD DEPTH SHALL BE 10" PER IRC R311.7.5. c. HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH 4 OR MORE RISERS. HANDRAIL HEIGHT SHALL BE NOT LESS THAN 34" AND NOT MORE THAN 38". HANDRAILS FOR STAIRWAYS SHALL BE CONTINUOUS FOR THE FULL LENGTH OF THE FLIGHT, FROM THE TOP TO THE BOTTOM RISER. HANDRAILS SHALL RETURN PER IRC R311.5.6.2. HANDRAILS ADJACENT TO A WALL SHALL BE A SPACE OF NOT LESS THAN 1-1/2" FROM THE WALL TO THE HANDRAIL PER IRC R311.7.8. d. INSTALL FIRE BLOCKING AT TOP AND BOTTOM OF STRINGER SPAN AND WALL ALONG STRINGER PER IRC R302.11. e. COVER USABLE SPACE UNDER STAIR WITH 1/2" GWB PER IRC R311.2.2 f. OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR ORNAMENTAL PATTERN SUCH THAT A SPHERE OF 4" OR MORE IN DIAMETER CANNOT PASS THROUGH PER IBC R312.1.3. g. DOORS TO THE EXTERIOR SHALL HAVE A MAXIMUM 7-3/4" STEP TO A MINIMUM 36" DEEP LANDING, BUT THE DOOR MAY NOT SWING OVER THE LANDING PER IRC R311.3 h. PORCHES, BALCONIES OR RAISED FLOOR SURFACES MORE THAN 30" ABOVE THE FLOOR OR GRADE SHALL HAVE GUARD RAILS NOT LESS THAN 36" IN HEIGHT PER IRC R312.1.1 & R311.1.2 8. FIRE PLACES AND SOLID FUEL BURNING APPLIANCES a. SOLID FUEL BURNING APPLIANCES INCLUDING SITE BUILT FIREPLACES, AIRTIGHT STOVES, FIREPLACE STOVES, FACTORY BUILT FIREPLACES, AND FIREPLACE INSERTS AND SHALL COMPLY WITH THE PROVISIONS OF THE IRC AND IBC. b. METAL CHIMNEYS SHALL BE ENCLOSED ABOVE THE STORY IN WHICH THE APPLIANCE SERVED IS LOCATED, IN WALLS HAVING 1-HOUR FIRE RESISTANCE RATING, AND WITH A SPACE ON ALL SIDES BETWEEN CHIMNEY AND THE ENCLOSING WALL SUFFICIENT FOR EXAMINATION AND REPAIR FOR ENTIRE CHIMNEY. c. PROVIDE FIREBLOCKING AT CHIMNEY PER IRC R1003.19. d. INSTALL FACTORY BUILT FIREPLACES WITH HEARTH AND SURROUNDS PER MANUFACTURER'S SPECIFICATIONS. e. PREFABRICATED FIREPLACES, CHIMNEYS AND RELATED COMPONENTS TO BEAR UL APPROVAL AND BE INSTALL PER MANUFACTURER'S REQUIREMENTS. f. THE HEARTH SHALL EXTEND AT LEAST 16" IN FRONT OF AND 8" TO EACH SIDE OF THE FIREPLACE OPENING WHEN THE OPENING IS SMALLER THAN 6 SF. IF THE OPENING IS 6 SF OR LARGER THE HEARTH SHALL EXTEND 20" IN FRONT AND 12" TO EACH SIDE, PER IRC R1001.10. g. ALL CHIMNEYS SHALL EXTEND AT LEAST 2'-0" ABOVE THE HIGHEST ELEVATION OF ANY PART OF THE BUILDING WITHIN 10'- 0" BUT SHALL NOT BE LESS THAN 3' ABOVE THE HIGHEST POINT WHERE THE CHIMNEY PASSES THROUGH THE ROOF PER IRC R1001.11. AND TABLE & FIGURE R1001.1 h. COMBUSTIBLE MATERIALS SHALL NOT BE PLACED WITHIN 2" OF THE FIREPLACE, SMOKE CHAMBER OF CHIMNEY WALL OR WITHIN 12" OF FIREPLACE OPENING. NO COMBUSTIBLE MATERIAL WITHIN 12" OF THE FIREPLACE OPENING SHALL PROJECT MORE THEN 1/8" FOR EACH 1" OF CLEARANCE FROM SUCH OPENING PER IRC R1003.18. 9. EXTERIOR DOORS AND WINDOW ASSEMBLIES a. ALL BUILDING ENTRANCE DOORS INCLUDING GARAGE DOORS SHALL BE EQUIPPED WITH LOCKS CONSISTING OF A DEAD LOCKING LATCH BOLT WITH AT LEAST 1/2" OF THROW WHICH PENETRATES THE STRIKE JAMB A MINIMUM OF 1/4". BUILDING ENTRANCE DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT A KEY OR SPECIAL KNOWLEDGE OR EFFORT. b. BUILDING ENTRANCE DOORS SHALL BE EQUIPPED WITH AN OBSERVATION PORT OR WINDOW SIDELIGHT. OBSERVATION PORTS SHALL BE INSTALLED AT MINIMUM 54" TO MAXIMUM 66" ABOVE THE FLOOR. c. ALL OPERABLE WINDOWS AND SLIDING GLASS DOORS INSTALLED WITHIN 10'-0" OF FINISH GRADE SHALL BE EQUIPPED WITH A LOCKING DEVICE. THIS LOCK SHALL BE INSTALLED SO IT'S MOUNTING HARDWARE IS INACCESSIBLE FROM THE EXTERIOR. 10. FIREBLOCKING SHALL BE PROVIDED TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERTICAL AND HORIZONTAL) AND TO FORM AN EFFECTIVE FIRE BARRIER BETWEEN STORIES, AND BETWEEN A TOP STORY AND THE ROOF SPACE. FIREBLOCKING SHALL BE PROVIDED IN WOOD FRAME CONSTRUCTION PER IRC R302.11. 11. FIBER CEMENT LAP SIDING SHALL BE LAPPED A MINIMUM OF 1-1/4- AND SHALL HAVE ENDS SEALED WITH CALKING, COVERED WITH AN H- SECTION JOINT COVER OR LOCATED OVER A STRIP OF FLASHING. FIBER CEMENT PANEL SIDING SHALL BE INSTALLED WITH THE LONG DIMENSION PARALLEL TO THE FRAMING. VERTICAL JOINTS SHALL OCCUR OVER FRAMING MEMBERS AND SHALL BE SEALED WITH CAULKING OR COVERED WITH BATTENS. HORIZONTAL JOINTS SHALL BE FLASHED WITH Z-FLASHING AND SOLID BLOCKED. ALL FIBER CEMENT SIDING INSTALLATION SHALL CONFORM TO MANUFACTURERS INSTRUCTIONS AND IRC R703.10. 12. APPROVED CORRISION-RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVELOPE IN SUCH A MANNER AS TO PREVENT THE ENTRY OF WATER INTO THE WALL CAVITY, REPEATED WETTING OF THE SHEATHING, OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE INSTALLED TO PREVENT WATER FROM RE-ENTERING THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION FLASHING SHALL BE INSTALLED AT ALL OF THE FOLLOWING LOCATIONS; a. AT THE TOP OF ALL EXTERIOR WINDOW AND DOOR OPENINGS IN SUCH A MANNER AS TO BE LEAKPROOF. b. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. C. UNDER AND AT THE ENDS OF ALL MASONRY, WOOD OR METAL COPINGS AND SILLS. d. CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM. e. WHERE EXTERIOR PORCHES, DECKS, HALF -WALLS, RAILINGS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION. f. AT WALL AND ROOF INTERSECTIONS g. AT BUILT IN GUTTERS. 13. UNDERLAYMENT FOR ROOF SLOPES FROM 2:12 TO 4:12 SHALL BE TWO LAYERS APPLIED IN THE FOLLOWING MANNER: APPLY A 19" STRIP OF UNDERLAYMENT FELT PARALLEL WITH AND STARTING AT THE EAVES, FASTENED SUFFICIENTLY TO HOLD IN PLACE. STARTING AT THE EAVE, APPLY 36" WIDE SHEETS OF UNDERLAYMENT, OVERLAPPING SUCCESSIVE SHEETS 19" AND FASTENED SUFFICIENTLY TO HOLD IT IN PLACE. FOR ROOF SLOPES OF 4:12 OR GREATER, UNDERLAYMENT SHALL BE ONE LAYER APPLIED IN THE FOLLOWING MANNER: UNDERLAYMENT SHALL BE APPLIED SHINGLE FASHION, PARALLEL TO AND STARTING FROM THE EAVE AND LAPPED 2 INCHES, FASTENED SUFFICIENTLY TO HOLD IT IN PLACE. END LAPS SHALL BE OFFSET BY 6 FEET, PER IRC R905.2.7. 14. ASPHALT SHINGLES SHALL HAVE SELF -SEAL STRIPS OR BE INTERLOCKING AND COMPLY WITH ASTMD225 OR D3462. 15. CLAY AND CONCRETE TILE SHALL BE INSTALLED AS PER MANUFACTURERS INSTALLATION INSTRUCTIONS AND IRC R905.3. 16. METAL ROOF SHINGLES AND METAL ROOF PANELS SHALL BE INSTALLED PER MANUFACTURERS INSTALATION INSTRUCTIONS AND IRC R905A AND R905.10. THE SLOPE OF METAL ROOFS SHALL BE A MINIMUM OF 3:12. STRUCTURAL NOTES SEE ALSO THE STRUCTURAL ENGINEER'S NOTES ON ATTACHED "S" SHEETS. THE FOLLOWING STRUCTURAL NOTES ARE SUPPLEMENTAL TO THE ENGINEERING NOTES. IN ANY CASE OF CONFLICT, THE ENGINEER'S STRUCTURAL NOTES SHALL SUPERSEDE THESE NOTES. 1. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO THE DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. 2. FOUNDATION SUPPORTING WOOD SHALL EXTEND AT LEAST 6" ABOVE THE ADJACENT FINISH GRADE. FOUNDATION WALL BACKFILL SHALL BE PLACED SIMULTANEOUSLY ON BOTH SIDES OF WALL. PROVIDE 4" PERFORATED PIPE FOR SUBSURFACE DRAINAGE. FOOTING SIZE SHALL BE AS INDICATED ON DRAWINGS OR PER IRC R405. 3. FOUNDATIONS WHERE THE SURFACE IS SLOPED MORE THAN ONE (1) FOOT IN TEN (10) FEET SHALL BE LEVEL OR SHALL BE STEPPED SO THAT BOTH TOP AND BOTTOM OF SUCH FOUNDATION ARE LEVEL PER IBC R403.1.5. 4. WHERE STRUCTURAL COLUMNS AND POSTS ARE EXPOSED TO WEATHER OR WATER SPLASH ABOVE A CONCRETE SURFACE, PROVIDE A MINIMUM 1" PIER OR METAL PEDESTAL ABOVE THE CONCRETE SURFACE. 5. FOUNDATION PLATES SHALL BE BOLTED TO THE FOUNDATION WITH STEEL BOLTS EMBEDDED INTO THE CONCRETE. THERE SHALL BE A MINIMUM OF TWO (2) BOLTS PER PIECE AND WITHIN 12" FROM EACH END PER IRC R403.1.6. SEE DRAWING FOR SIZE AND SPACING. 16. ALL STRUCTURAL PANEL COMPONENTS OF THE BUILDING SUCH AS SOFTWOOD PLYWOOD, PARTICLE BOARD, WAFER BOARD, AND OSB SHEATHING SHALL BE IDENTIFIED AS "EXTERIOR". 17. ADHERED AND ANCHORED VENEER SHALL CONFORM TO IRCR703. STRUCTURAL SHAPES USED FOR ANCHORED MASONRY VENEER LINTELS SHALL CONFORM TO R703.7.2.1. VENEER SHALL BE FLASHED PER IRC R703.7.5 AND R703.8. 18. ANCHORED VENEER SHALL BE PROVIDED WITH CORROSION RESISTANT ANCHOR TIES PER IRC R703.7.4. THE ANCHOR TIES SHALL BE SPACED A MAXIMUM OF 24" ON CENTER AND SUPPORT NO MORE THAT 2 SQUARE FEET OF VENEER. ADDITIONAL VENEER TIES SHALL BE PROVIDED AROUND ALL WALL OPENINGS GREATER THAN 16" IN EITHER DIRECTION PER R703.7.4.1.1. ELECTRICAL NOTES 1. ALL ELECTRICAL MATERIALS, WORKMANSHIP AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE INTERNATIONAL RESIDENTIAL CODE, INTERNATIONAL BUILDING CODE AND THE WASHINGTON STATE ELECTRICAL CODE, LATEST EDITION. VERIFY ALL CONDITIONS BEFORE PROCEEDING WITH WORK. 2. PROVIDE ELECTRICAL GROUND WIRES EMBEDDED IN FOUNDATION PER ELECTRICAL CODE. 3. 110 V HARD WIRED SMOKE DETECTORS WITH BATTERY BACKUP SHALL BE INSTALLED IN EACH SLEEPING ROOM AND IN ONE CENTRAL LOCATION ON EACH STORY OR LEVEL, PREFERABLY CLOSE TO THE STAIR LANDING. EACH SMOKE DETECTOR SHALL BE INTERCONNECTED SO AS TO SOUND ALARMS IN EACH ROOM OR AREA IF ONE DETECTOR IS TRIGGERED, PER IRC R313 6. CONCRETE SLABS ON GRADE SHALL BE 4" THICK MINIMUM. A 4" THICK DOOR AND WINDOW NOTES GRAVEL BASE COURSE SHALL BE PLACED ON THE PREPARED SUBGRADE WHEN THE SLAB IS BELOW GRADE PER IRC R506.2.2 1. EVERY SLEEPING ROOM AND HABITABLE ROOMS IN BASEMENTS SHALL HAVE AT LEAST ONE OPERABLE WINDOW WITH A NET CLEAR 7. A 6 MIL. POLYELETHENE VAPOR BARRIER WITH JOINTS LAPPED NOT OPENING OF 5.7 SF. THE OPENING HEIGHT SHALL BE 24" MINIMUM LESS THAN 6" SHALL BE PLACED BETWEEN THE CONCRETE FLOOR AND WIDTH 20" MINIMUM, WITH A FINISHED SILL HEIGHT NO MORE THE SLAB AND BASE COURSE PER IRC R506.2.3. 44" ABOVE THE FLOOR, PER IRC R310.1. IF WINDOW WELLS ARE NECESSARY THEY SHALL MEET THE REQUIREMENTS OF IRC R310.2. 8. NOTCHES IN SOLID LUMBER JOISTS, RAFTERS AND BEAMS SHALL NOT EXCEED ONE SIXTH OF THE DEPTH OF THE MEMBER, SHALL NOT BE 2. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE DESIGNED TO LONGER THAN ONE THIRD OF THE DEPTH OF THE MEMBER AND SHALL RESIST THE DESIGN WIND LOADS SPECIFIED IN TABLE R301.2(2) AND NOT BE LOCATED IN THE MIDDLE ONE THIRD OF THE SPAN. NOTCHES ADJUSTED FOR HEIGHT AND EXPOSURE PER TABLE R301.2(3). AT THE ENDS SHALL NOT EXCEED ONE FOURTH OF THE DEPTH OF THE MEMBER. THE TENSION SIDE OF MEMBERS 4" OR GREATER IN 3. EXTERIOR WINDOWS AND GLASS DOORS SHALL BE TESTED BY AN NOMINAL THICKNESS SHALL NOT BE NOTCHED EXCEPT AT THE ENDS. APPROVED INDEPENDENT LABORATORY AND BEAR A LABEL THE DIAMETER OF HOLES SHALL NOT EXCEED ONE THIRD OF THE IDENTIFYING MANUFACTURER, PERFORMANCE CHARACTERISTICS DEPTH NOR BE CLOSER THAN 2" TO THE TOP OR BOTTOM OF THE AND APPROVED INSPECTION AGENCY TO INDICATE COMPLIANCE MEMBER, PER IRC R802.7.1 WITH THE REQUIREMENTS OF IRC SECTION R308 9. ANY STUD IN AN EXTERIOR WALL OR BEARING PARTITION MAY BE CUT 4. GLAZING IN HAZARDOUS LOCATIONS SUCH AS: OR NOTCHED TO A DEPTH NOT EXCEEDING 25% OF ITS WIDTH, PER IRC R 602.6. a. PANES IN SWINGING, SLIDING, STORM OR BIFOLD DOORS, b. GLAZING WITHIN 24" OF A DOOR OPENING, 10. STRUCTURAL FLOOR MEMBERS SHALL NOT BE CUT, BORED OR NOTCHED c. GLAZING IN STAIRWAYS, IN EXCESS OF IRC R502.8 AND FIGURE R502.8. d. GLAZING IN SHOWER OR TUB SURROUNDS e. GLAZING IN GUARDS AND RAILINGS 11. CUTS, NOTCHES AND HOLES BORED IN LAMINATED VENEER LUMBER f. GLAZING CLOSER THAN 18" TO A FLOOR (LVL) GLU LAMINATED LUMBER (GLU LAM) OR I JOISTS ARE PERMITTED ONLY IN LOCATIONS APPROVED BY THE MANUFACTURER SHALL BE SAFETY GLAZING OR WIRE REINFORCED, TEMPERED OR AND CONSIDERED IN THE SPECIFIC DESIGN OF THE MEMBER, PER IRC LAMINATED SAFETY GLASS, OR SHATTER RESISTANT PLASTIC PER R802.7.2. IRC R308.4. GLAZING WITH THE EXPOSED EDGE WITHIN A 24" ARCH OF THE VERTICAL EDGE OF A DOOR SHALL BE 12. PREFABRICATED WOOD ROOF TRUSSES SHALL BE DESIGNED BY THE SAFETY GLAZING PER IRC R308.4 MANUFACTURER IN ACCORDANCE WITH ANSI/TPI1 FOR THE SPAN CONDITIONS SHOWN ON THE PLANS. 5. GLAZING IN SKYLIGHTS SHALL CONFORM TO IRC R308.6. STANDARD COMPOSITION ROOF LOADING SHALL BE: TOP CHORD LIVE LOAD 25 PSF TOP CHORD DEAD LOAD 12 PSF BOTTOM CHORD DEAD LOAD 5 PSF TOTAL LOAD 42 PSF STANDARD TILE ROOF LOADING SHALL BE: TOP CHORD LIVE LOAD 25 PSF TOP CHORD DEAD LOAD 25 PSF BOTTOM CHORD DEAD LOAD 5 PSF TOTAL LOAD 55 PSF 13. WOOD FLOOR TRUSSES SHALL BE DESIGNED IN ACCORDANCE WITH APPROVED ENGINEERING PRACTICES. SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS (COMPLETED WITH STRESS DIAGRAMS) FOR THE STRUCTURAL ENGINEER TO REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BEAR THE STAMPS AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON 14. WOOD ROOF TRUSSES SHALL UTILIZE APPROVED CONNECTOR PLATES (GANGNAIL OR EQUAL). SUBMIT SHOP DRAWINGS AND DESIGN CALCULATIONS (COMPLETED WITH STRESS DIAGRAMS) FOR THE STRUCTURAL ENGINEER TO REVIEW PRIOR TO FABRICATION. SUBMITTED DOCUMENTS SHALL BEAR THE STAMPS AND SIGNATURE OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. PROVIDE FOR SHAPES, BEARING POINTS, INTERSECTIONS, HIPS, VALLEYS, ETC., SHOWN ON DRAWINGS. EXACT COMPOSITION OF SPECIAL HIP, VALLEY, AND INTERSECTION AREAS (USE OF GIRDER TRUSSES, JACK TRUSSES, STEP-DOWN TRUSSES, ETC.) SHALL BE DETERMINED BY THE MANUFACTURER UNLESS SPECIFICALLY INDICATED ON THE PLANS. PROVIDE ALL TRUSS TO TRUSS AND TRUSS TO GIRDER TRUSS CONNECTION DETAILS AND REQUIRED CONNECTION MATERIALS. PROVIDE FOR ALL TEMPORARY AND PERMANENT TRUSS BRACING AND BRIDGING. IF TRUSS CONFIGURATION DIFFERS FROM THAT SHOWN ON ARCHITECTURAL PLAN, THE MANUFACTURER SHALL CONTACT THE ARCHITECT AND ENGINEER TO VERIFY SUPPORTING FRAMING. ALL TRUSSES SHALL COMPLY WITH IRC R802.10. 15. WOOD STRUCTURAL PANEL SHEATHING (PLYWOOD AND OSB) SHALL MEET REQUIREMENTS OF THE IRC R503.2. EACH PIECE SHALL BARE THE RATING STAMP OF THE APPROPRIATE AGENCY. MECHANICAL AND ENERGY NOTES 1. ALL WORK SHALL CONFORM TO THE SEATTLE MECHANICAL CODE, SEATTLE ELECTRICAL CODE, AND THE SEATTLE RESIDENTIAL CODE 2015 EDITIONS 2. SEE BUILDING SECTION FOR INSULATION RATINGS AND LOCATIONS. 3. KITCHEN RANGE FAN, EXHAUST FANS, AND CLOTHES DRYERS SHALL EXHAUST DIRECTLY TO THE OUTSIDE. VENTS SHALL BE SMOOTH, NON-COMBUSTIBLE, NONABSORBENT AND EQUIPPED WITH BACK - DRAFT DAMPER. ALL EXHAUST OUTLETS SHALL TERMINATE AT LEAST 3 FEET FROM ANY OPENING INTO THE BUILDING. 4. ENERGY CODE GENERAL NOTES: a. ELECTRICAL OR GAS WATER HEATERS SHALL HAVE THE FOLLOWING: i. SEPARATE POWER OR GAS SHUTOFF. ii. NONCOMBUSTIBLE R-10 PAD (UNHEATED SPACES ONLY) iii. 1987 NAECA LABEL ON TANK iv. TEMPERATURE SETTING OF 120 DEGREES F. b. SHOWER AND LAVATORIES SHALL LIMIT FLOW TO 2.6 GPM c. CEILING INSULATION: i. BAFFLES TO MAINTAIN 1" AIR SPACE ABOVE INSULATION ii. BAFFLES TO EXTEND 6" ABOVE BATT INSULATION iii. BAFFLES TO EXTEND 12" ABOVE LOOSE FILL INSULATION. d. WALL INSULATION SHALL BE: i. FACED, STAPLED BATTS, OR ii. FRICTION FIT UNFACED BATT WITH,4 MIL POLY VAPOR RETARDER, OR PVA PAINT WITH A DRY SUP PERM RATING OF 1.0 MAXIMUM. e. CONCEALED INSULATION SHALL BE PLACED BEHIND SHOWER/ TUB AND BEHIND PARTITION STUD/ CORNER. f. FLOOR INSULATION SHALL HAVE VAPOR BARRIER ON THE WARM SIDE. g. ATTIC AND CRAWL SPACE ACCESS PANELS SHALL BE INSULATED AND WEATHER STRIPED. h. RECESSED LIGHTING FIXTURES TO COMPLY WITH WSEC SECTION 502.4.4 i. VAPOR RETARDERS SHALL BE INSTALLED PER S.502.1.6. j. 6-MIL BLACK POLYETHYLENE GROUND COVER SHALL BE LAPPED 12" AT JOINT AND EXTEND TO FOUNDATION WALL IN CRAWL SPACE. k. ALL EXTERIOR DOORS (EXCEPT 20 MINUTE DOORS) SHALL BE WEATHER STRIPPED PER S.502.4.3. I. SERVICE HOT AND COLD WATER PIPING IN UNCONDITIONED SPACES SHALL BE INSULATED TO THE MINIMUM VALUES LISTED IN TABLE 5-12 AND SECTION 503.1.1. m. EACH DWELLING UNIT SHALL BE PROVIDED WITH HEATING FACILITIES CAPABLE OF MAINTAINING 70 DEGREES F AT A POINT 3'-0" ABOVE THE FLOOR IN ALL HABITABLE ROOMS WHEN THE OUTSIDE TEMPERATURE IS AS SET FORTH IN SECTION 305 WSEC, SECTION 310.11 OF UBC. FUEL BURNING APPLIANCES SHALL BE LISTED AND LABELED BY AN APPROVED AGENCY AND INSTALLED AND VENTED ACCORDING TO SPECIFICATIONS. PROVIDE A MINIMUM CLEAR WORKING SPACE OF 3" MINIMUM ALONG SIDES, BACK AND TOP OF APPLIANCE WITH 12" MINIMUM CLEARANCE TOTAL SIDE TO SIDE. m. AIRFLOW BETWEEN FRESH AIR PORTS AND THE WHOLE HOUSE FAN TO BE ENSURED BY UNDERCUT DOOR/ GRILLS In. ALL FIREPLACES SHALL HAVE: i. 6" SQUARE INCHES COMBUSTIBLE AIR SUPPLY DUCT WITH TIGHT FITTING DAMPER DIRECTLY CONNECTED TO THE FIREBOX ii. TIGHT FITTING GLASS OR METAL DOORS. iii. TIGHTLY FITTING FLUE DAMPER WITH MANUAL OR AUTOMATIC CONTROLS o. RADON MONITOR, PRINTED INSTRUCTIONS, AND INFORMATION SHEET SHALL BE SUPPLIED TO THE SINGLE FAMILY DWELLING OR FIRST FLOOR UNIT OF MULTIFAMILY DWELLING BY THE GENERAL CONTRACTOR AS REQUIRED BY WASHINGTON STATE. CONTACT INFORMATION. r1\A/KICD. MS. ANN TESTROET 915 MAPLE ST. EDMONDS WA 98020 (206) 437-7266 -------------- -------- Hardware and fasteners in contact with preservative -treated wood shall be of hot -dipped zinc galvanized steel, ARCHITECT: I stainless steel, silicon bronze or . i In the absence of manufacturer's recommendations a minimum of ASTM A 653 In. STANDARD AIR LEAKAGE (WSEC SECTION 502.4.3) CAULKING IS type G185zinc-coated galvanized steel, or i COMPLETE WHEN INSTALLED IN THE FOLLOWING LOCATIONS: KIT N EWMAN I equivalent, shall be used. IRC R317 3 1 IBC 2304 10 5 1 i. BETWEEN SOLE PLATE/ SUB FLOOR. ii. WIRING, PLUMBING/ DUCT REGISTER PENETRATIONS iii. RIM JOISTS/ MUD SILLS (HEATED LOWER FLOORS) iv. PARTITIONS/ STUD PENETRATIONS. v. LIGHT FIXTURE/ FLUE PENETRATIONS. vi. AROUND WINDOW AND DOOR FRAMES 5. MECHANICAL VENTILATION AND INDOOR AIR QUALITY CODE NOTES: a. EACH DWELLING UNIT SHALL BE EQUIPPED WITH SOURCE SPECIFIC AND WHOLE HOUSE VENTILATION SYSTEMS DESIGNED TO SATISFY THE REQUIREMENTS OF THE ARCHITECT 7600 LLC------- --- -----------� 112 D 2 2 N D AVENUE I WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO DETECTORS THROUGHOUT THE DWELLING IS REFER SEATTLE. WA 98122 I AND 315 OR MORE I NFORMATIONO 2018 IRC R314 --- --- ----- --- ---I (206) 605-3277 A SEPARATE PLUMBING PERMIT IS REQUIRED. PLEASE OBTAIN A PLUMBING PERMIT FROM THE CITY OF STRUCTURAL ENGINEER: EDMONDS CHRIS SHAW , P.E. DESIGN & CREATIVE PLLC PO BOX 28598 SEeft Vof'Edmonds b. MECHANICAL VENTILATION FAN DUCTS SHALL BE 4" OR PROPERLY SIZED USING SRC TABLE M1506.2 Building Department c. MECHANICAL VENTILATION SYSTEMS SHALL HAVE A TIMER, DEHUMIDSTAT OR SWITCH CONTROLS. Work ADDITION, REMODEL, DECKS d. MECHANICAL VENTILATION SYSTEMS SHALL HAVE R-4 INSULATION IN CONDITIONED SPACES - SRC M1507.3.6.4 Address 915 MAPLE ST PLUS BACK DRAFT DAMPER. SRC M1507.3.6.3.................................................................................... e. MECHANICAL VENTILATION SUPPLY DUCTS IN UNCONDITIO E®Wner TESTROET ................................................. SPACES SHALL HAVE R-4 INSULATION. Approved Date f. SUPPLY DUCTS SHALL HAVE VOLUME DAMPERS, OR EQUIVAL '1T, TO BALANCE SYSTEM. Building Official g. SUPPLY AND RETURN AIR DUCTS SHALL HAVE SEALED DUCT JOINTS IN UNCONDITIONED SPACES. Permit Number h. EXHAUST FANS SHALL BE: i. FLOW RATED AT 0.25 W.G. STATIC PRESSURE ii. SOUND RATED AT 1.0 SONES MAXIMUM FOR WHOLE HOUSE FAN. iii. INSULATED TO R-4 IN UNCONDITIONED SPACES. iv. EQUIPPED WITH A BACKDRAFT DAMPER. i. HVAC PLENUMS, SUPPLY, AND RETURN AIR DUCTS SHALL HAVE R-8 INSULATION j. OUTDOOR AIR INLETS: INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY INSECTS, LEAVES, OR OTHER MATERIALS. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE FOLLOWING AREAS: SRC M1507.3.5.3 i. CLOSER THEN TEN FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS THREE FEET ABOVE THE OUTDOOR AIR INLET. ii. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. ii. IN HAZARDOUS OR UNSANITARY LOCATIONS. iv. IN A ROOM OR SPACE HAVING FUEL -BURNING. APPLIANCES. v. CLOSER THEN TEN FEET FROM A VENT OPENING TO A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT vi. OPENING IS AT LEAST THREE FEET ABOVE THE AIR INLET. IN AN ATTIC, CRAWL SPACE OR GARAGE. k. SOURCE SPECIFIC VENTILATION SHALL BE PROVIDED IN EACH KITCHEN, BATHROOM, WATER CLOSET, LAUNDRY ROOM, SPA, INDOOR SWIMMING POOL ENCLOSURE AND ANY OTHER ROOMS WERE EXCESS WATER VAPOR OR ODOR IS PRODUCED. I. WHOLE HOUSE VENTILATION SYSTEMS: EACH DWELLING UNIT SHALL BE EQUIPPED WITH A WHOLE HOUSE VENTILATION SYSTEM THAT SHALL BE CAPABLE OF PROVIDING AT LEAST 0.35 AIR CHANGES PER HOUR, BUT NOT LESS THEN 15 CFM PER BEDROOM PLUS AND ADDITION 15 CFM. WHOLE HOUSE VENTILATION SYSTEM SHALL SUPPLY OUTDOOR AIR TO ALL 1 OF 1 AO Al A2 A3 A4 A5 A6 A7 DM1 S1 S2 S3 6/10/2024 ---------------------------------- BLD2024-0191 ---------------------- SITE SURVEY ARCHITECTURAL GENERAL NOTES ARCHITECTURAL SITE PLAN FOUNDATION PLAN 1 st FLOOR PLAN RESU B ARCHITECTURAL ROOF PLAN Jun 05 2024 DMONDS SOUTH & WEST ELEVATIONS CITY M ETSERVI DEVELOPMENT SERVICES DEPARTMENT NORTH & EAST ELEVATIONS BUILDING SECTIONS & INTERIOR ELEVATIONS DEMOLITION PLANS STRUCTURAL GENERAL NOTES & DETAILS STRUCTURAL DETAILS STRUCTURAL FOUNDATION & ROOF PLANS OBTAIN ELECTRICAL PERMIT FROM STATE LABOR & INDUSTRIES HABITABLE ROOMS THROUGH INDIVIDUAL OUTDOOR AIR INLETS, FORCED AIR HEATING SYSTEMS, DUCTING OR EQUIVALENT. OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING OWNER/CONTRACTOR IS RESPONSIBLE FOR ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY EROSION CONTROL AND DRAINAGE UTILITIES MAY REQUIRE A SEPERATE PERMIT. APPROVED PLANS MUST BE ON JOB SITE Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED Jd] WAt" t U 06/11/2024 VV W U Z w en H W 0 t� W H 0 N O O'*, N H Z N � In 0 V � 0 0 0 w Z � O <n H w V J a Z � O "? V o,.* 7�jQQ REGISTERED \\ ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECT'S ORIGINAL SIGNATURE IN BLUE INK REVISIONS L1 4.17.2024 PERMIT CORRECTIONS CYCLE #1 IN LZ 6.4.2024 PERMIT CORRECTIONS CYCLE #2 .e III e 9 0 DRAWN BY K.NEWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # AO ALL DISTURBED SOILS SHALL BE COMPOST AMENDED PER CITY OF GUTTERS/DOWNSPOUTS SHALL EDMONDS STANDARD DETAIL SD-642 OR DRAIN TO SPLASHBLOCKS APPROVED EQUAL. OC 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. EQUIPMENT & PROCEDURES METHOD OF SURVEY. SURVEY PERFORMED BY FIELD TRAVERSE AND REAL TIME KINEMATIC GPS POSITIONING UTILIZING THE HxGN SMARTNET NETWORK INSTRUMENTATION: LEICA TS15 ROBOTIC ELECTRONIC TOTAL STATION LEICA VIVA GNSS GS08 RECEIVER ALL EQUIPMENT HAS BEEN MAINTAINED IN ADJUSTMENT TO MANUFACTURER'S SPECIFICATIONS AS REQUIRED BY WAC 331-130-100 PRECISION: MEETS OR EXCEEDS STATE STANDARDS SET BY WAC 332-130-080 THROUGH 332-130-110 BASIS OF BEARING: THE MONUMENTED CENTERLINE OF 9TH AVENUE SOUTH AS THE BEARING OF NORTH 00'00'00" EAST. SURVEY REFERENCES (R1) RECORD OF SURVEY - AFN 199908125005 (R2) CITY OF EDMONDS SHORT PLAT - AFN 200108105001 (R3) RECORD OF SURVEY - AFN 201605275028 (R4) CITY OF EDMONDS BLA - 201810035011 NOTES 1.) BOUNDARY LINES SHOWN AND CORNERS SET REPRESENT DEED LOCATIONS, OWNERSHIP LINES MAY VARY. NO GUARANTEE OF OWNERSHIP IS EXPRESSED OR IMPLIED. THIS SURVEY WAS PERFORMED WITHOUT THE BENEFIT OF A TITLE REPORT AND DOES NOT PURPORT TO SHOW ALL EASEMENTS, RESTRICTIONS, RESERVATIONS, AND OCCUPATION WHICH MAY ENCUMBER TITLE OR USE OF SUBJECT PROPERTY. FOUND CASED CONC. MON. " BRASS DISC W1 -X- DOWN0.3 , VISITED 06106123 HELD FOR BEARING LEGAL DESCRIPTION LEGEND LOTS 35 AND 36, BLOCK 69, THE CITY OF EDMONDS, ACCORDING TO • SET 1/2" X 24" REBAR W/CAP STAMPED PCS 37536" THE PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. O EXISTING REBAR W/CAP, AS NOTED 0 I SITUATE IN THE CITY OF EDMONDS, COUNTY OF SNOHOMISH, STATE OF }( SET NAIL AND WASHER STAMPED 'PCS 37536" N WASHINGTON. O I� FOUND CONCRETE MONUMENT AS NOTED m RIGHT OF WAY CENTERLINE IN O IW Q I` m O � I p O to I z N 90'00'00" E_659 86' _ -------------— - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - — - �------ DAYTON ST ----�, i FOUND CASED CONC. MON W12 DISC IN 2" IRON PIPE DOWN 0.2, VISITED 06106123 HELD FOR POSITION I 30' ' I LOT 1 LOT 2 LOT 3 j LOT 4 LOT 5 j LOT 6 LOT 7 LOT 8 LOT 9 �I THE CITY QF EDMONDS BLK. 69, VOL. 2, PG. 39 I I I I I I RTH FACE OF MAPLE WAY (ALLEY) FOUN 18894 "1120.2'(S) &R0.1A(W) WALP END OS N 0'(S) OF LINE ' OF CORNER N 89'59'10" W 59.99' --------------------------------------------- I NORTH FACE CORNER WOOD FENCE WOOD FENCE 1.0' I OF WALL IS 1.1 '(S) & 1.5'(E) OF CORNER \ j FENCE CORNER IS I i 1' 9 'S II 1.8'(S) & 2.4'(E) i OF CORNER 4 3, F---� END OF FENCE IS I LOT 2 LOT 36 I I 0.9'(E) OF LINE CITY OF EDMONDS SHORT PLAT I I l Oq W SP-2000-95 _ _ _ _ _ _ — I W 0 15.2' i I N AFN 200108105001 O �r I � 3 SITE AREA I ' o I 00 I I WEST FACE OF WALL = I o I 6,587 SF I IS 0.5(E) OF LINE THE CITY OF EDMONDS i o 00434206903500 O\ Z I I F — , 4.6' BLK. 69, VOL. 2, PG. 39 Q L 1.5' I I z i HOUSE J915 z LOT 34 LOT 33 LOT 32 ' I WEST FACE OF WALL X L — — — IS 0.3(E) OF LINE FENCE INTERSECTION LOT 35 0 I I I J IS 1.3'(W) OF LINE o 'u I LOT 1 W z ' I CITY OF EDMONDS SHORT PLAT WLu x z z j SP-2000-95 30' i AFN 200108105001 g o.l'(E) 2 I I I I END OF WEST FACE OF ' I FENCE CORNER IS 0.9 (N) END OF FENCE IS I I WALL IS 0.9'(N) & 0.2'(W) & 1.1 '(E) OF CORNER 0.2'(N) OF LINE i I OF CORNER ' L---------------------------------------------- X ----------------------L------ ' FOUND 1/2" REBAR CAP N 89'58'21 " W 59.99' o "18894" 0.4'(W) OF CORNER 1 CORNER OF WALL S CORNERo_ )l( SET NAIL & WASHER 10.00'(S) OF CORNER ON PROPERTY LINE EXTENDED i of MAPLE ST 209.96' --------— - — - — - — - — - — - — - — - — - — - — - — - — - — - N 89'58'21" W 659.86'-----------------------------------�----- ---�i I I I AUDITOR'S CERTIFICATE SURVEYOR'S CERTIFICATE FILED FOR RECORD THIS _______ DAY OF -------- 2023, THIS MAP CORRECTLY REPRESENTS A SURVEY MADE BY ME OR UNDER MY AT ________ M., IN BOOK _______ OF SURVEYS, AT PAGE DIRECTION IN CONFORMANCE WITH THE REQUIREMENTS OF THE SURVEY _______ , AT THE REQUEST OF PACIFIC COAST SURVEYS, INC. RECORDING ACT AT THE REQUEST OF ANN TESTROET IN MAY 2023. COUNTY AUDITOR DEPUTY COUNTY AUDITOR REGISTRATION NO. 37536 SCALE: 1" =20' 0 20 40 J. 4 Pacific Coast Surveys, Inc. � RI g of Wq . xl� LAND SURVEYING & MAPPING � z P.O. 60X 1361g 0 �37536 E4 S GI $ MILL CREEK, WA 98o82 IO` LP119D PH. 425•512.7099 FAX 425.357.3577 www.PCSurveys.net A. F. NO. RECORD OF SURVEY FOR: ANN TESTROET SW 1/4 SE 1/4, SEC.24, T.27N., R.3E., W.M. DRAWN BY DATE DRAWING FILE NAME SCALE JOB N0. ARK c6.21.23 233 047ros. D WG 1" = 20' 23-304 RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TEMPORARY EROSION & STORMWATER CONTROL NOTES (TESL): 1. ALL DISTURBED AREAS TO BE COMPOST AMMENDED PER 2019 SWMMWW BMP T.5.13. 2. INSTALL & MAINTAIN ALL TESC MEASURES ACCORDING TO THE APPROVED PLANS, CITY OF EDMONDS STANDARD DETAILS, AND ALL OTHER MEASURES THAT MAY BE REQUIRED DURING CONSTRCTION. 2" x 2" WOOD/STEEL FILTER FABRIC SECURED TO 2" x 2" 14 GA WIRE FABRIC EQUAL A NATIVE BACKFILL MATERIAL 8. 0 I CV FILTER FABRIC MATERIAL IN CONTINOUS ROLLS USE STAPLES OR WIRE RINGS TO ATTACH FABRIC TO WIRE 2" x 2" WOOD/STEEL POSTS 1 WIRE MESH FENCE 0I FTO BR CPPORT FILTER C-4 m `BURY BOTTOM OF FILTER `-4 MATERIAL 8" TO 12" 6' MAX NOTES: 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN AND ENSURE PROPER EROSION CONTROL THROUGHOUT PROJECT. CITY INSPECTION REQUIRED ON 2. SILT FENCE TO BE PLACED DOWNSLOPE OF CONSTRUCTION ALL EROSION CONTROL METHODS ACTIVITY. BEFORE OTHER WORK CAN BEGIN REVISION DATE CITY OF EDMONDS FILTER FABRIC FENCE JANUARY 2018 FILTRATION SYSTEMS _ PUBLIC WORKS STANDARD DEPARTMENT DETAIL Fs t g 9 APPROVED BY: R. ENGLISH E R— 9 0 0 E R-900 NOT TO SCALE _LS 4 TH IN DE FULL WIDTH GRESS/EGRESS DETAIL NOTES: O THE MINIMUM LENGTH SHALL BE EXTENDED AS NECESSARY TO ENSURE MATERIAL IS NOT TRACKED OFF SITE AND/OR INTO THE PUBLIC RIGHT-OF-WAY. O ATB DRIVEWAY RAMP AND/OR SITE ACCESS ROAD 15' WIDE MIN. SEE TABLE BELOW FOR REQUIRED LENGTH. NOTES: 1. SURFACE WATER - ALL SURFACE WATER FLOWING OR DIVERTED TOWARD CONSTRUCTION ENTRANCES SHALL BE PIPED ACROSS THE ENTRANCE. IF PIPING IS IMPRACTICAL, A MOUNTABLE BERM WITH 5:1 SLOPES WILL BE PERMITTED. 2. MAINTENANCE - THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL QUARRY SPALLS AS CONDITIONS DEMAND AND REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO TRAP SEDIMENT. ALL SEDIMENT SPILLED, DROPPED, WASHED OR TRACKED OFF SITE AND/OR ONTO PUBLIC RIGHT-OF-WAY MUST BE REMOVED IMMEDIATELY. 3. WHEELS SHALL BE CLEANED TO REMOVE SEDIMENT PRIOR TO LEAVING THE SITE. WHEN WASHING IS USED, IT SHALL BE DONE ON AN AREA STABILIZED WITH QUARRY SPALLS AND WHICH DRAINS INTO AN APPROVED SEDIMENT TRAPPING DEVICE. 4.INSPECTION AND NEEDED MAINTENANCE SHALL BE PROVIDED AFTER EACH RAIN. PROJECT SIZE MIN LENGTH OF (FEET) QUARRY SPALLS* < 1/4 ACRE 30 < 1 ACRE 50 < 3 ACRE 100 > 3 ACRE 100 *PROVIDE ATB OR ASPHALT TRANSITION WHERE FRONTAGE ROAD IS AN ARTERIAL. LENGTH TO BE DETERMINED BY CITY INSPECTOR. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN REVISION DATE CITY OF EDMONDS STABILIZED CONSTRUCTION JANUARY 2018 ENTRANCE P PUBLIC WORKS STANDARD DEPARTMENT DETAIL St. 1 g 9 0 APPROVED BY: R. ENGLISH E R— 9 01 E R-901 NOT TO SCALE CONC. WALL \—(E) WOOD FENCE TYP. REAR B.S.B.L. _ HEAT PUMP UNIT CONC. WALL PROPERTY CORNER IN WOOD STEPS TUB DEC 80 sI 143 ADDITIO 4 05 EXIST. BLDG. FOOTPRIN 1 374 s Ft W I I <a I I I a<u WATER SERVICE LINE �I W o M FRONT B.S.B.L. O y W WOOD FENCE TYP. PAVER PA @ GRADE I 67 sq Ft i n _4 < EXIST. CONC. PATH & STOOP v 1 v \1 v I tin � \1 1.5' �I II EMODEL\\ RE,�`� DSO M d. d < 12.5' I _ 4.61, 4 <.00 d �2 <CID < I 0� O <Q d < d_ < d d < LU I O J O 00 O O a &4 a a < d d < a d Q m I W O o 3 O L z o d U OU d < a 552 sq Ft a d < d . (IST SIDE SEWER TO d < STREET d d d <, < d d < 4 d < 9' a Nothing in the permit approval process shall e interpreted as allowing or permitting the mair itenance of any currently existing illegal, nonconformin o., or unpermitted building, structure or site conditi n which J is outside the scope of the permit application, regardless of whether such building, structure or conditi n is shown on the site plan or drawing. Such buile ing, structure or condition may be the subject of a separate enforcement action. APPROVED BY PLANNING Jun 17 2024 W Zone RS-6 Setbacks - Front Sides(W,E) Rear Other Height w U Z w N w 8" CONC. BLOCK Cie BULKHEAD WALL UJ (N) TYPE II EV CHARGING RECEPTACLE LOCATION. 0 SEE ALSO PLAN ON SHEET A3 FOR MORE INFORMATION z N W H IMPERVIOUS SURFACE AREAS: EXISITNG RESIDENCE 1,374 SF NEW ADDITION 138 SF EXIST. CONC DRIVEWY. 552 SF EXIST. CONC. PATH 67 SF NEW PAVER PATIO 143 SF NEW HOT TUB DECK 80 SF NEW DECK 306 SF TOTAL IMPERV. AREA 2,660 SF 2,660 SF _ 6,567 SF = 0.4038 ( 40.38% OF LOT AREA) N PROPERTY CORNER 0 4' 8' 16' SITE PLAN SCALE: 1 /8" = 1'-0" REGISTERED �7600 ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECT'S ORIGINAL SIGNATURE IN BLUE INK REVISIONS Q 4.17.2024 PERMIT CORRECTIONS CYCLE #1 Q6.4.2024 PERMIT CORRECTIONS CYCLE #2 III e 9 fi - -� --1 DRAWN BY K. N EWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # (C)2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. TYP. EXTERIOR WALL CONSTRUCTION W/ SIDING PER ELEVS. TYP. NEW ADDITION FLOOR ASSEMBLY: FINISH FLR'G. PER OWNER 3/4" T&G PLYWD SUBFLR'G. R-30 BATT INSULATION IN JOIST BAYS 2X10 DF#2 FLOOR JOISTS @ 16" O.C. 2X10 RIM JOIST MET. WATERTABLE FLASHING W/ DRIP EDGE 10 2X6 PT. MUDSILL. A.B.'S PER STRUCT. FIN. GRADE Qo 6 MIL. V.B. 8" CONC. STEM WALL PER PLAN , REINF PER STRUCT. DETAILS zn IED M O G 0 v v v � 24" DEEP GRAVEL BED a. a NEW FLOOR FRAMING @ STEM WALL SCALE: 1 " = 1'-0" 2X6 FINISH CAP RAILING (2) 1X4 FINISH SUB RAILINGS TOP & BOTTOM 4X4 RAILING POST. SPACING PER PLAN N 1X2 & 1X4 ALTERNATING °p N RAILING PICKETS SPACED 1 1/2" APART M PT. 2X10 DECK JOISTS @ 16" O.C. 1X4 SPACED WD RESIN DECKING TYP. 2 1/2" X 1 1/2" WOOD WATERTABLE TRIM TYP. 1/4" 0 GALV ALL THREAD THRU BOLTS !' !2�7 DTT2Z TENSION TIE W/ (8) 1 /4" 0 X 1 1 /2"SDS SCREWS TO JOIST OR BLK'G. AS REQ'D. 2X10 BAND TRIM PT. 2X10 RIM JOIST PT. 4X10 DECK BEAM PER PLAN SADDLE SEAT TO CONC. PIER PER STRUCT FIN. GRADE 12" 0 CONC. SONOTUB PIER. \77/—/\77/7----REINF. PER STRUCT. 24" SQ. X 8" CONC. MAT FTG. REINF. PER STRUCT. DECK FRAMING @ CONC. PIERS SCALE: 1" = 1'-0" NEWDECKFRAMING @ DOOR THRESHOLD SCALE: 1 " = 1'-0" 1/2" PLYWD. SUBFLR. 2" R-10 RIGID FOAM BD. INSUL 2X PT. SLEEPERS @ 24" O.C. STUDIO SLAB AT NEW WALL FRAMING SCALE: 1" = 1'-0" EXIST. FLOOR CONSTRUCTION EW EXT. DOOR & FRAME TYP. EW MET. SILL PAN FLASHING TYP. 2X10 JOISTS @ 16" O.C. TYP. ;4 SPACED WD RESIN DECKING TYP.I !) STAGGERED ROWS 1/4"0 X 4" kG SCREWS @ 16" O.C. !) EA. PER JOIST BAY 210 HANGER f. 2X10 RIM JOIST KIST. WD. SHEATHING XIST. CRAWL SPACE TYP. ST. CONC. STEM WALL & FTG. 0 TYP. NEW 2X6 WALL CONST. ONT. 2X4 BLOCKING NAILE .B.'S PER STRUCT DETAILS IST. CONC SLAB ON GRADE THICKENED SLAB FTG. PER STRUCT DETAILS RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FOUNDATION PLAN NOT TO SCALE J W en 0 p ` O W co CC o` REGISTERED �7600 ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECT'S ORIGINAL SIGNATURE IN BLUE INK REVISIONS Q 4.17.2024 PERMIT CORRECTIONS CYCLE #1 Q6.4.2024 PERMIT CORRECTIONS CYCLE #2 F .e III e 9 0 L - - -- 1 - -1 DRAWN BY K. N EWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # (C)2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. ADDITIONAL ENERGY & MECHANICAL NOTES: PER 2018 WASHINGTON STATE ENERGY CODE (RESIDENTIAL) 1) ALL EXISTING EXTERIOR 2X4 WALLS AT THE 1 ST FLOOR, WHERE THE STUD BAYS ARE TO BE EXPOSED AS PART OF THE RENOVATIONS, SHALL RECEIVE NEW R-15 PAPER FACED BATT INSULATION. 2) ALL NEW 2X6 EXTERIOR WALLS SHOWN AT THE NEW ADDITION AND REMODELED EXISTING SPACES TO RECEIVE NEW R-21 PAPER FACED BATT INSULATION. 3) AREAS OF EXISTING ATTIC SPACES ABOVE THE FIRST FLOOR, THAT ARE EXPOSED AS PART OF THESE RENOVATIONS, SHALL RECEIVE NEW R-49 BATT INSULATION MINIMUM, WHILE MAINTAINING A MIN. 1" AIRSPACE ABOVE FOR VENTILATION BELOW THE ROOF SHEATHING. 4) EXPOSED FLAT CEILINGS WITH ATTIC ABOVE ON THE 1 ST FLOOR TO RECEIVE R-49 BATT INSULATION. 5) ALL MAIN LEVEL FLOOR FRAMING JOIST BAYS OVER UNHEATED CRAWL SPACE TO RECEIVE R-30 BATT INSULATION. 6) EXISTING WINDOWS SHOWN TO REMAIN ON THE MAIN FLOOR ARE VINYL FRAMED & DOUBLE GLAZED WITH DEFAULT U-VALUE OF 0.55 7) ALL NEW WINDOWS AND EXTERIOR DOORS SHOWN AT THE NEW ADDITION, AND REMODELED EXISTING AREAS, MUST ACHIEVE A MAX. TESTED U-VALUE OF <_ 0.30 8) THIS PROJECT ADDS AND REMODELS A TOTAL OF 323 SF OF NEW CONDITIONED FLOOR AREA. THEREFORE PER 2018 WSEC R406.3.5 IT REQUIRES 1.5 ADDITIONAL ENERGY CREDITS PER TABEL R406.3. SEE BELOW FOR ENERGY CREDITS TO BE OBTAINED FOR THIS PROJECT. 9) THE EXISTING GAS FURNACE LOCATED IN THE GARAGE IS TO BE DECOMMISSIONED AND REMOVED. IT SHALL BE REPLACED WITH A NEW AIR SOURCE, CENTRALLY DUCTED ELECTRIC HEAT PUMP SYSTEM WITH A MINIMUM HSPF [11.0]. SEE PLAN FOR NEW UNIT LOCATION . COMPLIES WITH 2O18 WSEC TABLE R406.3 OPTION 3.5 FOR 1.5 ENERGY CREDITS. 10) A MINIMUM OF 90% OF PERMANENTLY INSTALLED LAMPS IN NEW LIGHTING FIXTURES TO BE HIGH -EFFICACY LAMPS. (LED OR CF) 11) CONTRACTOR SHALL COMPLETE AND POST AN "INSULATION CERTIFICATE FOR RESIDENTIAL CONSTRUCTION" WITHIN 3' OF THE MAIN ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. 12) ALL EXHAUST FANS SHOWN ON THIS PLAN SHALL VENT TO THE EXTERIOR TYP. PER PLAN. ALL FANS SHOWN ON THE PLANS SHALL RUN INTERMITTENTLY UNLESS NOTED OTHERWISE. GLAZING SCHEDULE MARK WIDTH HEIGHT OPERATION QTY. AREA "U" COMMENTS 1 2'-0" 3'-0" FIXED 1 6 N/A NEW WINDOW IN (E) ROUGH OPEN'G./TEMPERED OBSCURE GLAZING 2 2'-0" 31-4" CASEMENT 1 7 0.30 MAX NEW WINDOW IN (E) ROUGH OPEN'G./TEMPERED GLAZING/ factory mull #9 3 2'-10" 4'-5" SINGLE HUNG 2 13 0.55 EXISTING WINDOW TO REMAIN 4 2'-6" 4'-0" SINGLE HUNG 2 10 0.30 MAX NEW FIBERGLAS FRAMED WINDOW 5 5'-0" 3'-6" SLIDER 1 18 0.30 MAX NEW FIBERGLAS FRAMED WINDOW 6 4'-6" 3'-4" SLIDER 1 15 0.30 MAX NEW WINDOW IN (E) ROUGH OPEN'G 7 4'-11" 4'-5" SLIDER 1 22 0.30 MAX NEW WINDOW IN (E) ROUGH OPEN'G 8 6'-8" 4'-8" DBL. SINGLE HUNG 1 31 0.55 EXISTING WINDOW TO REMAIN 9 8'-0" 3'-4" FIXED PICTURE 1 27 0.30 MAX NEW WINDOW IN (E) ROUGH OPEN'G./TEMPERED GLAZING/ factory mull #2 172 ft2 GLAZING SCHEDULE NOTES: 1) ALL WINDOWS SHADED GREY ON THE SCHEDULE ABOVE ARE EXISTING WINDOWS TO REMAIN AS IS UNDER THIS PERMIT. LISTED U-VALUES ARE PER THE DEFAULT VALUES IN TABLE R303.1.3(1) 2) NEW WINDOWS LISTED ON THIS SCHEDULE ARE TO BE FIBERGLASS FRAMES, DOUBLE GLAZED, ARGON FILLED, W/ LOW-E COATINGS, & SPACERS TO ACHIEVE A NFRC TESTED U-VALUE OF:5 0.30 TYP. CONTRACTOR TO CONFIRM U-VALUES FOR NEW UNITS WITH THE MANUFACTURER AND/OR DISTRIBUTOR. NO. WIDTH HEIGHT OPERATION QTY. AREA U VALUE COMMENTS A 5'-0" 6'-8" DBL. SWING 1 34 SF 0.39 PR 26 EXTERIOR WOOD FRAMED (75%) DBL. GLAZED DOOR WITH LOCKSET/TEMPERED SAFETY GLZN'G/( B 3'-0" 6'-8" SWING 1 20 SF 0.39 30 EXTERIOR WOOD FRAMED (75%) DBL. GLAZED DOOR WITH LOCKSET /TEMPERED SAFETY GLZN'G /G C 6'-0" 6'-8" DBL. SWING 1 68 SF 0.39 PR 30 EXTERIOR WOOD FRAMED (75%) DBL. GLAZED DOOR WITH LOCKSET/TEMPERED SAFETY GLZN'G/( 122 SF TOTAL DOOR SCHEDULE A A7 BUILDING SQUARE FOOTAGE SUMMARY: (E) RESIDENCE 890 SF (N) ADDITION & REMODELED GARAGE AREA 323 SF TOTAL OF CONDITIONED SPACES 1213 SF NEW ADDITION & REMODELED CONDITIONED SPACE IS: 323 SF THEREFORE PER 2018 WSEC R406 .5.5 - (1.5) ENERGY CREDITS ARE REQUIRED RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W UO j z V) Z W o w�Z �vO cry O ::E w o0 Cle z H O n W H w O U i a � cle Q � N � Z W O Lo H V o,.* 7600 REGISTERED \\ ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECT'S ORIGINAL SIGNATURE IN BLUE INK REVISIONS Q4.17.2024 PERMIT CORRECTIONS CYCLE #1 Q6.4.2024 PERMIT CORRECTIONS CYCLE #2 � e .e III e 9 0 DRAWN BY K.NEWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # A3 ( 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. ARCH COMPOSITION ASPHALT SHINGLES (2) LAYERS 60 MIN. BLG. PAPER UNDRLYMNT. 1/2" CDX PLYWD. SHT'G. NAILING PER STRUCT. 2X12 HF #2 RAFTERS @ 24" O.C. 8" THK. MIN. SPRAY APPLIED POLY ISO CLOSED CELL FOAM INSUL. FOR R-49 MIN. 5/8" GWB @ CEILING FINISH PAINT PER OWNER CONT. 2X12 RIM MTL. GUTTER 1X8 CONT. FINISH FASCIA 1X6 CONT. SUB FASCIA CEMENT BD. LAP SIDING PER ELEVATIONS AIR/VAPOR BARRIER (TYVEK, WEATHERSHEILD, OR EQ. 1/2" CDX PLYWD. SHT'G. NAILING PER STRUCT. 2X6 HF #2 STUDS @ 16" O.C. R-21 PAPER FACED BATT INSUL. IN STUD BAYS 1/2" GWB @ INTERIOR WALL FINISH PAINT PER OWNER TYPICAL EAVES @ 2X12 RAFTERS SCALE: 1" = 1'-0" PROVIDE LAMINATED SAFETY GLAZING AT ALL SKYLIGHTS PER IRC R308.6.2 TYP. CONTINUE ROOFING MEMBRANE & UNDERLYMNT. UP CANT STRIP &CURB 1/2" GWB TYP. LINER FINISH BL 2X12 BLOCKING @ SKYLIGHT R.O. TYP. ROOF CONSTRUCTION SKYLIGHT CURB DETAIL SCALE: 1" = 1'-0" (N) 2X12 RAFTERS OVERFRAME EXIST. ROOF R-21 BA EXIST. ROOF STRUCTURE, INSUL, & CEILING FIN. TO REMAIN. (E) ROOFING & UNDRLYMNT. REMOVED NEW RAFTERS OVER (E) EXT. WALL. SCALE: 1" = 1'-0" SKYLIGHT UNIT PER PLAN. INSTALLATION, ATTACHMENT & FLASHINGS PER MANUFACTURER CURB PER MFG. R.O. DIMENSIONS CANT STRIP @ CURB TYP. (4) SIDES 8" THK. POLYISO CLOSED CEL FOAM INSUL TYP. TYPICAL ROOF CONSTRUCTION: ARCH COMPOSITION ASPHALT SHINGLES (2) LAYERS 60 MIN. BLG. PAPER UNDRLYMNT. 1/2" CDX PLYWD. SHT'G. NAILING PER STRUCT. 2X12 HF #2 RAFTERS @ 24" O.C. 8" THK. MIN. SPRAY APPLIED POLY ISO CLOSED CELL FOAM INSUL. FOR R-49 MIN. 5/8" GWB @ CEILING FINISH PAINT PER OWNER N) 2X4 WD. STUDS @ 16" O.C. CANT STRIP VERIFY OR PROVIDE (2) 2X FULL DEPTH BLK'G. EXIST T.O. WALL N) 1/2" GWB INT. WALL FINISH EXIST. EXT. STUD WALL FRAMING, GWB, & SHEATHING TO REMAIN ROOF FRAMING PLAN NOT TO SCALE RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT J W en 0 p ` O W co CC o` REGISTERED �7600 ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECTS ORIGINAL SIGNATURE IN BLUE INK REVISIONS Q 4.17.2024 PERMIT CORRECTIONS CYCLE #1 Q6.4.2024 PERMIT CORRECTIONS CYCLE #2 .e III e 9 O DRAWN BY K. N EWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # A4 OC 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. SOUTH ELEVATION SCALE: 1 /4" = 1'-0" WEST ELEVATION SCALE:1/4" = 1'-0" RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W 00 j zN Z W o w]�:Z �vO cry O ::E w o0 z H o n W H w U O i a Cie � Q �=,= N � Z W O Lo r� H V o,.* 0 REGISTERED \\ ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECTS ORIGINAL SIGNATURE IN BLUE INK REVISIONS Q4.17.2024 PERMIT CORRECTIONS CYCLE #1 Q6.4.2024 PERMIT CORRECTIONS CYCLE #2 � O .e III e 9 O DRAWN BY K.NEWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # A5 ( 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. NORTH ELEVATION SCALE: 1 /4" = P-0" EAST ELEVATION SCALE: 1/4" = 1'-0" RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W 00 j zN Z W o w]�:Z �vO cry O ::E w o0 z H o n W H w U O i a Cie � Q �=,= N � Z W O Lo r� H V o,.* 0 REGISTERED \\ ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECTS ORIGINAL SIGNATURE IN BLUE INK REVISIONS Q4.17.2024 PERMIT CORRECTIONS CYCLE #1 Q6.4.2024 PERMIT CORRECTIONS CYCLE #2 � O .e III e 9 O DRAWN BY K.NEWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # A6 ( 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. UPPER WALL CAB. 31-011 DRIP DRY ROD CA CABS. SHELVES PANTRY W/ PULLOUT SHLVS. U 11611 0000 DRYER W? 2'-01, �o 0000 WASHER 0 no PULLOUT CLOTHES HAMPER T-011 TUB SINK . 21-611 1-911 BASE STORAGE 11-9 CABS.- P� LAUNDRY - NORTH SCALE: 1/2" = V-0" ART STUDIO - EAST SCALE: 1/2" = l'-O" O 24 FLUSH PANEL 26 FLUSH PANEL CLOSET DR. Q STIL. DR. 1 '-0 J10 TILED STEPS ART STUDIO - SOUTH SCALE: 1/2" = 1'-0" LAU N DRY - EAST SCALE: 1/2" = l'-O" ART STUDIO - WEST SCALE: 1/2" = V-0" KNEE SPACE cl) KNEE SPACE BASE CAB —DRAWERS o DRAWERS ART STUDIO - NORTH SCALE: 1/2" = P-O" 7 19 NEW BATHRM. INDOW LAUNDRY - SOUTH SCALE: 1/2" = l'-O" 6 CASE OPENING &_LAU LAUNDRY -LE 1 �VEST SC = _r_o. A/2 BUILDING SECTION B-B SCALE: 1/4" = 1'-0" RESUB Jun 05 2024 BUILDING SECTION A -A JCITY OF EDMONDS DEVELOPMENT SERVICES SCALE: 1/4" = P-0" DEPARTMENT I REGISTERED �7600 ARCHITECT AUTHORIZED PRINTS BEAR THE ARCHITECT'S ORIGINAL SIGNATURE IN BLUE INK REVISIONS A4.17.2024 PERMIT CORRECTIONS CYCLE #1 A26.A.202A PERMIT CORRECTIONS CYCLE #2 III e O DRAWN BY K.NEWMAN ISSUE DATE 2.12.2024 JOB # 23003 SHEET # A7 OC 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. 13'-0" ± TO PROVIDE TEMPORARY IS RIDGE DURING CONST. TYP. ROOF FRAMING DEMOLITION PLAN NOT TO SCALE REMOVE EXIST. SIDI WOOD STRUCTURE r------- --------------------------I 1st FLOOR DEMOLITION PLAN SCALE: 1 /4" = 1'-0" N RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT 7600 REGISTERED ARCHITECT CHRISTOPHER M. NEWMAN AUTHORIZED PRINTS BEAR THE ARCHITECTS ORIGINAL SIGNATURE IN BLUE INK REVISIONS � o i DRAWN BY K.NEWMAN ISSUE DATE 1.9.24 JOB # 23003 SHEET # Dml nC 2024 ARCHITECT7600 LLC, ALL RIGHTS RESERVED. GENERAL STRUCTURAL NOTES (The following apply unless shown otherwise on the plans) CRITERIA 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS, AND THE SEATTLE BUILDING CODE (2018 EDITION). 2. DESIGN LOADING CRITERIA ROOF SNOW LOAD............................................................... 25 PSF FLOOR LIVE LOAD (RESIDENTIAL)...................................................40 PSF DECK LIVE LOAD (RESIDENTIAL).................................................... 60 PSF TRUSS TOP CHORD DEAD LOAD (INCLUDES 5PSF SOLAR PANEL LOAD) ................. 20 PSF TRUSS BOTTOM CHORD DEAD LOAD ............................................... 10 PSF LATERAL LOADS - WIND 1. BASIC WIND SPEED 98 MPH 2. IMPORTANCE FACTOR 1.0 3. Kzt 1.0 4. EXPOSURE B S. INTERNAL PRESSURE COEFF. +/- 0.18 LATERAL LOADS - SEISMIC 1. SEISMIC IMPORTANCE FACTOR 1=1.0 2. STRUCTURAL OCCUPANCY CATEGORY II 3. MAPPED SPECTRAL RESPONSE ACCELERATIONS Ss=1.286g, S1=0.452g 4. SPECTRAL RESPONSE COEFFICIENTS Sos=1.028g, So1=09 5. BUILDING LOCATION 47.8091357 N, 122.3662558 W 6. SITE CLASS D 7. SEISMIC DESIGN CATEGORY D 8. BASIC SEISMIC FORCE RESISTING SYSTEM LIGHT FRAMED SHEAR WALL 9. DESIGN BASE SHEAR 8.4 KIPS 10. RESPONSE MODIFICATION FACTOR R = 6.5 11. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE CONTRACTORS WORK. THE ENGINEER HAS NO OVERALL SUPERVISORY AUTHORITY OR ACTUAL AND/OR DIRECT RESPONSIBILITY FOR THE SPECIFIC WORKING CONDITIONS AT THE SITE AND/OR FOR ANY HAZARDS RESULTING FROM THE ACTIONS OF ANY TRADE CONTRACTOR. THE ENGINEER HAS NO DUTY TO INSPECT, SUPERVISE, NOTE, CORRECT, OR REPORT ANY HEALTH OR SAFETY DEFICIENCIES TO THE OWNER, CONTRACTORS, OR OTHER ENTITIES OR PERSONS AT THE PROJECT SITE. 7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT AND ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITION ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE ENGINEER. 9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. QUALITY ASSURANCE 10. THE OWNER SHALL RETAIN A SPECIAL INSPECTOR TO PERFORM THE SPECIAL INSPECTION REQUIREMENTS AS REQUIRED BY THE BUILDING OFFICIAL AS OUTLINED IN SECTION 1704 OF THE SEATTLE BUILDING CODE. THE ARCHITECT, STRUCTURAL ENGINEER, AND BUILDING DEPARTMENT SHALL BE FURNISHED WITH COPIES OF ALL INSPECTION AND TEST RESULTS. SPECIAL INSPECTION OF THE FOLLOWING TYPES OF CONSTRUCTION EPDXY GROUTED INSTALLATIONS PER ESR REPORT OTHER ELEMENTS AS REQUIRED BY JURISDICTION GEOTECH N ICAL 11. FOUNDATION NOTES: ALLOWABLE SOIL PRESSURE AND LATERAL EARTH PRESSURE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY A QUALIFIED SOILS ENGINEER OR APPROVED BY THE BUILDING OFFICIAL. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED, NOTIFY THE STRUCTURAL ENGINEER FOR POSSIBLE FOUNDATION REDESIGN. FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH FREE FROM ORGANIC MATERIALS AT LEAST 18" BELOW ADJACENT FINISHED GRADE. UNLESS OTHERWISE NOTED, FOOTINGS SHALL BE CENTERED BELOW COLUMNS OR WALLS ABOVE. FOOTING EXCAVATION SHALL BE FREE OF LOOSE SOILS, SLOUGHS, DEBRIS AND FREE OF WATER AT ALL TIMES. IF ORGANIC SILT AND/OR FILL MATERIAL IS ENCOUNTERED AT SUBGRADE, OVER -EXCAVATE A MINIMUM OF 2'-0" BELOW THE DESIGN FOUNDATION SUBGRADE ELEVATION PRIOR TO PLACING FOOTINGS. THE OVER -EXCAVATED AREAS SHALL BE BACKFILLED WITH STRUCTURAL FILL COMPACTED TO 95% PROCTOR PER ASTM D-1557 OR A LEAN CONCRETE MIX. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE DRAINAGE. ALLOWABLE SOIL PRESSURE .......................................... 2000 PSF LATERAL EARTH PRESSURE (RESTRAINED/UNRESTRAINED) ..........55 PCF/35 PCF COEFICIENT OF FRICTION (FACTOR OF SAFETY OF 1.5 INCLUDED) ............. 0.3 RENOVATION 12. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED AND IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 PSF. 13. EXISTING REINFORCING SHALL BE SAVED WHERE AND AS NOTED ON THE PLANS. SAW CUTTING, IF AND WHERE USED, SHALL NOT CUT EXISTING REINFORCING THAT IS TO BE SAVED 14. CONCRETE SHALL BE MIXED PROPORTIONED CONVEYED AND PLACED IN ACCORDANCE WITH SBC SECTION 1905, 1906, AND ACI 301, INCLUDING TESTING PROCEDURES. NORMAL WEIGHT CONCRETE SHALL ATTAIN A 28-DAY STRENGTH OF 2500 PSI. 5Y2 SACKS OF CEMENT PER CUBIC YARD OF CONCRETE AND A MAXIMUM OF 6 GALLONS OF WATER PER 94 LB SACK OF CEMENT. MAXIMUM SLUMP IS 4". MIXES SHALL BE PROPORTIONED TO ACCOMMODATE PLACEMENT. SLUMP, W/C RATIO, ADMIXTURES, AND AGGREGATE SIZE WILL BE DETERMINED BY THE CONTRACTOR IN ACCORDANCE WITH ACI. 15. ALL CONCRETE WITH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO ASTM C260, C494, and C618. TOTAL AIR CONTENT FOR FROST -RESISTANT CONCRETE SHALL BE IN ACCORDANCE WITH ACI 318-14 SECTION 19.3.3.1. 16. REINFORCING STEEL #4 AND SMALLER SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 40, fy = 40,000 PSI. REINFORCING STEEL #5 AND LARGRER SHALL SHALL BE GRADE 60, fy = 60,000 PSI. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. 17. DETAILING OF REINFORCING STEEL (INCLUDING HOOKS AND BENDS) SHALL BE IN ACCORDANCE WITH ACI 315-92 AND 318-19. LAP ALL CONTINUOUS REINFORCEMENT #5 AND SMALLER 50 BAR DIAMETERS OR 2'-0" MINIMUM. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS #5 AND SMALLER 50 BAR DIAMETERS OR 3'-0" MINIMUM. LAPS OF LARGER BARS SHALL BE MADE IN ACCORDANCE WITH ACI 318-19 , CLASS B. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 18. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS AND OTHER UNFORMED SURFACES CAST AGAINST EARTH. 3" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#6 BARS OR LARGER) 2" FORMED SURFACES EXPOSED TO EARTH OR WEATHER (#5 BARS OR SMALLER) 1-1/2" COLUMN TIES OR SPIRALS AND BEAM STIRRUPS 1-1/2" SLABS AND WALLS (INT. FACE) GREATER OF BAR DIAMETER PLUS 1/8" OR 3/4" 19. CAST -IN -PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES, BOTH CAST -IN -PLACE AND PRECAST. ANCHORAGE 20. EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BARS) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "AT-XP" AS MANUFACTURED BY SIMPSON STRONGTIE COMPANY INC. INSTALL IN STRICT ACCORDANCE WITH IAPMO LIES REPORT NO. ER-263. RODS SHALL BE ASTM A-36 GALVANIZED, UNLESS OTHERWISE NOTED. INT9161C 21. FRAMING LUMBER SHALL BE KILN DRIED OR MC-19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: 2X & 3X MEMBERS HEM FIR NO. 2 MINIMUM BASE VALUE, Fb = 850 PSI 2x10, 4X and LARGER MEMBERS DOUGLAS FIR NO. 2 MINIMUM BASE VALUE, Fb = 900 PSI 22. GLUED -LAMINATED MEMBERS SHALL BE MANUFACTURED AND IDENTIFIED IN CONFORMANCE WITH ANSI A190.1, ANSI 117 AND ASTM D3737, WITH STRESS CLASS 24F-1.8E IN A CERTIFIED PLANT. EACH MEMBER SHALL BEAR AN IDENTIFICATION AND GRADING MARK AND SHALL BE ACCOMPANIED BY AN ANSI A190.1 CERTIFICATE OF CONFORMANCE. CERTIFICATES OF CONFORMANCE MUST BE MADE AVAILABLE TO BUILDING INSPECTORS. CITY INSPECTION IS REQUIRED PRIOR TO COVERING GLUED LAMINATED MEMBERS. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, f'b = 2400 psi, fv=265 psi AND ALL CANTILEVERED BEAMS AND COLUMNS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, f'b = 2400 psi, fv=265 UNLESS NOTED OTHERWISE. CAMBER ALL SIMPLE SPAN GLULAM BEAMS TO 3500' RADIUS OR ZERO CAMBER, UNLESS SHOWN OTHERWISE ON THE PLANS. 23. MANUFACTURED LUMBER PSL, LVL, AND LSL, SHALL BE MANUFACTURED UNDER A PROCESS APPROVED BY THE ASTM D5456. EACH PIECE SHALL BEAR A STAMP OR STAMPS NOTING THE PRODUCT AND MANUFACTURER NAME, PLANT NUMBER OF THE MANUFACTURER, THE GRADE, AND THE QUALITY CONTROL AGENCY. ALL PSL, LVL, AND LSL LUMBER SHALL BE MANUFACTURED IN ACCORDANCE WITH ICC REPORT ESR-1387 AND SHALL BE MANUFACTURED USING VENEER GLUED WITH A WATERPROOF ADHESIVE MEETING THE REQUIREMENTS OF ASTM D2559 WITH ALL GRAIN PARALLEL WITH THE LENGTH OF THE MEMBER. THE MEMBERS SHALL HAVE THE FOLLOWING MINIMUM PROPERTIES: PSL (2.OE) BEAMS Fb = 2900 PSI, E = 2000 KSI, Fv = 290 PSI LVL (1.9E) BEAMS Fb = 2600 PSI, E = 1900 KSI, Fv = 285 PSI LSL (1.5E) BEAMS Fb = 2325 PSI, E = 1500 KSI, Fv = 310 PSI 24. DESIGN SHOWN ON PLANS IS BASED ON TRUS-JOIST PRODUCTS MANUFACTURED BY THE WEYERHAEUSER CORPORATION. ALTERNATE MANUFACTURERS MAY BE USED SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND STRUCTURAL ENGINEER OF RECORD. ALTERNATE BEAM HANGERS AND OTHER HARDWARE MAY BE SUBSTITUED FOR ITEMS SHOWN PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. ALL BEAM HANGERS AND OTHER HARDWARE SHALL BE COMPATIBLE IN SIZE WITH MEMBERS PROVIDED. 25. MANUFACTURED LUMBER PRODUCTS SHALL BE INSTALLED WITH A MOISTURE CONTENT OF 12% OR LESS. THE CONTRACTOR SHALL MAKE PROVISIONS UPON RECEIPT OF MATERIAL AND DURING CONSTRUCTION TO PREVENT THE MOISTURE CONTENT OF INSTALLED BEAMS FROM EXCEEDING 12%. EXCESSIVE DEFLECTIONS MAY OCCUR IF MOISTURE CONTENT EXCEEDS THIS VALUE. 26. PLYWOOD SHEATHING SHALL BE APA RATED, GRADE C-D, EXTERIOR GLUE OR STRUCTURAL II, EXTERIOR GLUE IN CONFORMANCE WITH SBC 2304.8 AND TABLE 2304.8(2). ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE RATING AND PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. ROOF SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 32/16. FLOOR SHEATHING SHALL BE 3/4" (NOMINAL) WITH SPAN RATING 48/24. WALL SHEATHING SHALL BE 1/2" (NOMINAL) WITH SPAN RATING 24/0. REFER TO WOOD FRAMING NOTES BELOW FOR TYPICAL NAILING REQUIREMENTS. 27. ALL WOOD IN DIRECT CONTACT WITH CONCRETE OR MASONRY, EXPOSED TO WEATHER, OR THAT REST ON EXTERIOR FOUNDATION WALLS AND ARE LOCATED WITHIN 8" OF EARTH, SHALL BE PRESSURE -TREATED WITH AN APPROVED PRESERVATIVE. NAILS, SCREWS, BOLTS W/NUTS AND WASHERS, ANCHOR BOLTS, HOLDOWNS AND ANY OTHER STEEL DEVICES IN DIRECT CONTACT WITH THE TREATED WOOD SHALL BE EITHER STAINLESS STEEL OR GALVANIZED PER THE MANUFACTURER TO PREVENT DIRECT CONTACT BETWEEN THE STEEL AND THE TREATED WOOD. TAPED AND PAINTED SEPARATION TECHNIQUES MUST BE IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS AND RECEIVE PRIOR APPROVAL FROM THE ARCHITECT AND ENGINEER. 28. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG -TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NUMBER C-2017. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICBO APPROVAL FOR EQUAL OR GREATER LOAD CAPACITIES. PROVIDE NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTOR STRAPS CONNECT TWO MEMBERS, PLACE ONE-HALF OF THE NAILS OR BOLTS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG SCREWS BEARING ON WOOD. UNLESS NOTED OTHERWISE, ALL NAILS SHALL BE AS CALLED OUT BELOW. ALL SHIMS SHALL BE SEASONED AND DRIED AND THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. UNLESS OTHERWISE NOTED ON THE DRAWINGS, USE MINIMUM CONNECTOR FOR FOR MEMBER INSTALLED WITH MAXIMUM NAILING. 29. WOOD FASTENERS A. NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 6d 2" 0.113" 8d 2-1/2" 0.131" 10d 3" 0.148" 12d 3-1/4" 0.148" 16d BOX 3-1/2" 0.135" SIDS 1/4 SIMPSON STRONG TIE 1/4 LAG SCREW MINIMUM EMBEDMENT OF 2.5 INCHES IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION) FOR REVIEW AND APPROVAL. B. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTERSINKING PERMITTED. C. BOLTS - ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60-70% OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" DIA AND SMALLER LAG SCREWS. 30. WOOD FRAMING NOTES --THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS A. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. MINIMUM NAILING, UNLESS OTHERWISE NOTED, SHALL CONFORM TO TABLE 2304.10.1 OF THE IBC. COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS BEARING ON WOOD. INSTALLATION OF LAG BOLTS SHALL CONFORM TO NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. B. WALL FRAMING: REFER ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID -HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT. ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH TWO 16d NAILS, AND TOENAIL WITH (4) 8d NAILS OR END NAIL WITH (2) 16d NAILS ON EACH STUD TO BOTTOM PLATE. FACE NAIL DOUBLE TOP PLATE WITH 16d @ 12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16d NAILS @ 4" O.C. EACH SIDE JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS @ 16" O.C. STAGGERED OR BOLTED TO CONCRETE WITH 5/8" DIAMETER ANCHOR BOLTS (WITH 7" MINIMUM EMBEDMENT) @ 4'-0" O.C. UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT- UP POSTS SHALL BE NAILED TO EACH OTHER WITH 16d @ 8" O.C. STAGGERED. WHEN NOT OTHERWISE NOTED, PROVIDE GYPSUM WALLBOARD ON INTERIOR SURFACES NAILED TO ALL STUDS, TOP AND BOTTOM PLATES, AND BLOCKING WITH NAILS @ 7" O.C. NAIL 1/2" GWB WITH 5d COOLER NAILS AND 5/8" GWB WITH 6d COOLER NAILS. PROVIDE 1/2" (NOMINAL) APA RATED SHEATHING (SPAN RATING 24/0) ON EXTERIOR SURFACES NAILED AT ALL PANEL EDGES (BLOCK UNSUPPORTED EDGES), AND TOP AND BOTTOM PLATES WITH 8d NAILS @ 6" O.C. AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8d NAILS @ 12" O.C. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS. C. FLOOR AND ROOF FRAMING: PROVIDE DOUBLE JOISTS UNDER ALL PARALLEL PARTITIONS THAT EXTEND OVER MORE THAN HALF THE JOIST LENGTH AND AROUND ALL OPENINGS IN FLOORS OR ROOFS UNLESS OTHERWISE NOTED. PROVIDE SOLID BLOCKING AT ALL BEARING POINTS. TOENAIL JOISTS TO SUPPORTS WITH TWO 16d NAILS. ATTACH TIMBER JOISTS TO FLUSH HEADERS OR BEAMS WITH SIMPSON METAL JOIST HANGERS IN ACCORDANCE WITH NOTES ABOVE. NAIL ALL MULTI -JOIST BEAMS TOGETHER WITH (2) ROWS OF 16d NAILS @ 12" O.C. STAGGERED. UNLESS OTHERWISE NOTED ON THE PLANS, PLYWOOD ROOF AND FLOOR SHEATHING SHALL BE LAID UP WITH GRAIN PERPENDICULAR TO SUPPORTS AND NAILED WITH 10d @ 6" O.C. TO FRAMED PANEL EDGES, STRUTS AND OVER STUD WALLS AS SHOWN ON PLANS AND WITH 10d @ 12"O.C.T0 INTERMEDIATE SUPPORTS. PROVIDE APPROVED PLYWOOD EDGE CLIPS CENTERED BETWEEN JOISTS/TRUSSES AT UNBLOCKED ROOF SHEATHING EDGES. ALL FLOOR SHEATHING EDGES SHALL HAVE APPROVED T&G JOINTS OR SHALL BE SUPPORTED WITH SOLID BLOCKING. ALLOW 1/8" SPACING AT ALL PANEL EDGES AND ENDS OF FLOOR AND ROOF SHEATHING. TOENAIL BLOCKING TO SUPPORTS WITH 16d @ 12" O.C. WITH MINIMUM OF (2) 16d PER BLOCK UNLESS OTHERWISE NOTED. SHEARWALL SCHEDULE MARK SHEATHING PANEL EDGE A35, LS50 OR BOTTOM PLATE BASE NAILING (I) LTP4 CLIPS CONNECTION Q CONNECTION® SW6 1%2" 8d @ 6"oc @ 28"oc 16d @ 6"oc %"O A.B. @ 60"oc7 SW4 1%2" 8d @ 4"oc @ 20"oc 16d @ 4"oc %"O A.B. @ 48"oc7 SW3 1%2" 8d @ Yoc @ 14"oc 16d @ 4"oc /"0 A.B. @ 36"oc7 1. BLOCK PANEL EDGES WITH 2X FLAT AND NAIL PANELS TO INTERMEDIATE SUPPORTS w/ 8d @ 12"oc 2. PROVIDE BLOCKING BENEATH WALL ENDS WHERE FRAMING IS NOT PRESENT. 3. TWO STUDS MINIMUM ARE REQUIRED AT EACH END OF ALL SHEARWALLS AN ALL END STUDS SHALL RECEIVE EDGE NAILING. 4. EACH ANCHOR BOLT (A.B.) SHALL YB" 0 WITH 7" MIN EMBEDMENT. INSTALL WITH NUT AND 3,,X3,,X0.25,, PLATE WASHER. WASHER MUST EXTEND TO WITHIN Y2" OF THE PLATE EDGE WHERE CONNECTION TO SHEATHING OR RIM OCCURS. AT DOUBLE SIDED SHEARWALLS, STAGER ON BOTH PLATE EDGES. 5. SEE DETAILS 1, 1.1 & 1.2 FOR TYPICAL CONDITIONS AND ASSEMBLIES. 6. -- 7. AT EXISTING FOUNDATION, INSTALL YB"0 STRONGBOLT 2 WITH 5 Y2" EMBEDMENT AT CENTER OF STEM WALL. INSTALL WITH 8" MIN DISTANCE TO END OF STEM WALL. RAFTER PER PLAN ROOF SHEATHING PER PLAN 10d @ 6" oc DIAPHRAGM BOUNDARY NAILING 2X SOLID EAVE BLOCKING VENT HOLES AT CENTER AS REQUIRED LS50 TOP PLATE TO BLOCKING PER SW SCHEDULE EDGE NAILING PER SV ROOF TO SHEARWALL SW ABOVE PER PLAN WALL BOTTOM PLATE NAILING PER SW SCHEDULE O EDGE NAILING PER SW SCHEDULE O SW BELOW PER PLAN ED DIAPHRAGM PER PLAN RIM JOIST OR BLOCKING TYP EDGE NAILIN( PER SV SCHEDULI O SW PER PLA 10d @ 6" oc DIAPHRAGM BOUNDARY NAILING (4) 10d SHEATHING TO BLOCK FLOOR & JOISTS PER PLAN ua L o Oc UIHF?iKH(iIVI BOUNDARY NAILING 4)10d @ 6" oc SHEATHING TO BLK'G JOIST PER PLAN EDGE NAILING PER SW SCHEDULE O BLOCKING @ 2) 1Od TO TOP PLATE CLIP PER SWO SCHEDULE /SHEATHINGAT IN LIEU OF LAPPED EDGE NAILING 2X BLKG @ 48"oc w/ (4) 0.131"0AILS PER SW SCHEDULE CONTRACTORS PREFERENCE O ALTERNATE (IN LIEU OF SHEATHING LAPPED (cD RIM JOIST) FLOOR TO SHEARWALL SW PER PLAN A.B. PER SW SCHEDULE ® WALL BOTTOM PLATE NAILING PER SW SCHEEDDULE P/T SILL PLATE - TYP 3 EDGE NAILING PER SW SCHEDULE 1 FOUNDATION PER PLAN TOP OF RETAINED SOIL AT SLAB ON GRADE FLOOR TO FOUNDATION ALTERNATE 10d @ 6" oc DIAPHRAGM BOUNDARY NAILING CLIPS PER SW SCHEDULE O (4) 10d SHEATHING TO BLOCK FLOOR & JOISTS PER PLAN 2X BLKG @ 48"oc w/ (4) 0.131"0 A.B. PER SW SCHEDULE P/T SILL PLATE - TYP FOUNDATION PER PLAN AT CRAWLSPACE (4) 10d KING STUD TO HEADER@ TOP PLATE CONT EXTERIOR OVER OPENING CONDITIONS KING STUD FULL BEARING FULL BEARING WHERE TOP PLATE IS BROKEN ATr v 2X TRIMMER @ HEADER BEARING: CONDITIONS SHOWN ARE TYPICAL AT ALL (1) TRIMMER @ DBL 2X HEADER (2)TRIMMERS @ 4X HEADER FRAMING SUPPORTS UNLESS NOTED OTHERWISE TYP BEAM HEADER BEARI NG (8) 16d EVENLY SPACED STUDS 4'-0" MIN @ LAPPED TOP PLATE WHERE TOP PLATE IS BROKEN AT HEADER, PROVIDE OCS18 w/ (11) 8d EACH END BOTH SIDES nr UE:AnCo CLIP PER SW O SCHEDULE 2 IN LIEU OF LAPPED SHEATHING AT CONTRACTORS PREFERENCE @DROPPED HEADER TYP TOP PLATE SPLICE E.S. TYP PROVIDE: (3) STUDS @ 4X BEAM (4) STUDS @ 6X BEAM (5) STUDS @ 7X BEAM OR GIRDER TRUSS TYP U.N.O. 16d STAGGERED @ 12" oc TYP FACE NAILS DBL 2X TOP PLATE WHERE TOP PLATE IS BROKEN PROVIDE OCS18 w/ (11) 8d EACH ENDE".r, @BREAK HOLDOWN SCHEDULE FASTENERS ANCHOR NOTES DETAIL MARK REFERENCE ST6224 (26)16d _ _ EQUAL NAILS TO EACH 6/S2 CONNECTED MEMBER SB Ysx24 8" MIN STEM. 2%" MIN EDGE DISTANCE HTTSKT (26) SD#10x2 Y2" Y80 12" EMBED IN AT-XP. THREADED ROD CENTER OF WALL 1. DEEPEN FOUNDATION AS NECESSARY TO PROVIDE SPECIFIED EMBEDMENT. 2. ATTACH HOLDOWN TO SHEARWALL END MEMBERS. 3. MIN END MEMBER, (2) STUDS STITCH NAILED WITH 10d STAGGERED @ 6" oc 4. INSTALL PER MANUFACTURERS INSTRUCTIONS 10d @ SPACING PER SHEARWALL SHEDULE O TYP STRAP WHERE SPECIFIED* HOLDOWN WHERE SPECIFIED* FSHEARWALL PER PLAN STAGGER STAGGER NAILS 10d @ SPACING PER SHEARWALL SHEDULE O TYP HOLDOWN WHERE SPECIFIED* AT CORNER AT INTERIOR * REFER TO HOLDOWN SCHEDULE AND GENERAL NOTES FOR MINIMUM MEMBER AND ATTACHMENT REQUIREMENTS TYPICAL SHEARWALL INTERSECTIONS STAGGER NAILS RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT W U �(3)/ O E w 0 L 4_j c/) N CT) a to a) Q Ln O Ln E 'r Cil L U a °° CD o < >Ln Lf1 Q 00 00 N O N N W -- 2 CO a Ln O� N X O %/ ■ m li O V JURISDICTION APPROVAL STAMP BELOW PROJECT #: x23-0801 DATE: 12/08/23 REV DATE: S1 BLOCKING BETWEEN JOISTS 4X4 MINIMUM GUARD POST 10d @ 4" oc 4'-0" OC MAX^, LOOR SHEATHING DIAPHRAGM W CJ PER PLAN BOUNDARY NAILING DTT2Z w/ 42 )12" 0 SS A304 (3)4X BLOCKING w/ MAX (4) %4"0 X 4%" SDS THROUGH JOIST THREADED ROD INTO END OF BLOCKING AT GUARD .N ATTACHMENT LOCATIONS 2 (3) STRAP PER PLAN CENTERED BETWEEN MEMBERS INSTALL WITH FULL NAILS Q BEAM OR COLLECTOR BEAM, TOP PLATE OR OTHER N SHEATHING PER 10d @ 6" oc JOISTS PER PLAN PER PLAN COLLECTOR PER PLAN PLAN DIAPHRAGM SHEARWALL BOUNDARY NAILING SW PER PLAN CONNECTION INSTALL w/ 2" CT) PER DETAIL 1.1 WASHER TYP BEAM E Q SOLID }' P;2,X ' BLOCKING ABOVE LU COLLECTOR POST BEAM I N SHEARWALL TO STRAP MAY BE INSTALLED ROOF -INTERIOR TYPICAL STRAP TIE AT FACE OF BEAMS GUARD POST ANCHORAGE o 5 TYPICAL COLLECTOR 5.1 6 7 a) � -0 H Or) L U SHEARWALL 10d @ 6" oc - P/T LEDGER TO MATCH JOISTS 8 8 DROP FOR FLOOR PER PLAN 2 DRAINAGE PER ARCH 7 • XV 0 X 6" SIDSF;7 STAGGERED @ 8"oc A JOISTS PER PLAN JOISTS PER PLAN JOIST HANGER TO LEDGER A- ELEVATION DECK LEDGER CONNECTION DTT2Z MECHANICAL TIE w/ NUT & WASHER EACH END INSTAL WITH %" 0 THREADED F DECK SHEATHING DECK JOIST/BE @ JOIST PARALLEL DECK LATERAL ATTACHMENT N.T.S. 24 #4 x F—@ 12" oc POST OR BEAM #4 @ 12" oc (HOR)1 ATTACHED ON ABU PLINTH: 8" ROUND w/ \ PER PLAN REINFSLAB I I r #30 @ 8"oc j TOP OF SOIL MINIMUM. DEEPEN AS \ I SLAB ON GRADE PER PLAN. NECESSARY FOR SLOPE AS REQ. FOR DRAINAGE 3„ HOEDOWN EMBEDMENT /\� (1) #4 CONT @TOP & } BEARING �- (2) #4 CONT @ BOTTOM SOIL I 16" MIN THICKENED EDGE FOOTING 6" MIN 12" MAX 2" MIN GRADE (4) #4 @ w/ 18" STD HOOK MIN IN FTG 48" MAX FOOTING PER PLAN ��----_----- 3" CLR BEARING o SOIL / EXTERIOR POST FOOTING WITH PLINTH DTT2Z MECHANICAL TIE w/ NL WASHER EACH END INSTAL WITH %" 0 THREADED F IR DIST DECK SHEATHING FR7 @ JOIST PERPENDICULAR NEW FOUNDATION REINF PER PLAN- TYP KlAu---A—K--k3) 3"oc TERMINATE NEW FOUNDATION REINF AT EXISTING FOUNDATION w/ 4" EPDXY EMBED IN SIMPSON AT-XP EPDXY -TYP NEW TO EXISTING FOUNDATION SEE DETAIL 1 FOR TOP 8" CONNECTION REQUIREMENTS. 8" A.B. PER DIAPHRAGM MUST BE IN PLACE A.B. PER PLAN BEFORE BACKFILLING. PLAN OTHERWISE PROVIDE (2) #4 CONT 6" TEMPORARY BRACING 2" CLEAR MIN TOP OF SOIL • #4 @ #4 (2) #4 CONT 13" oc @ 18" oc 12" MIN (HOR) (VERT) 3'-6" 2" CLEAR DEEPEN AS W 00 MAX REQUIRED a #4 @ #4 @ FOR SLAB • SLAB co O 13" oc 18„ HOEDOWN oc Q Ln (HOR) ((VERT) MIN ANCHOR \ \ /\ r EMBED FOOTING \ /� 6a0 DRAIN BY / /. STD HOOK + OTHERS \ \ �/ (A m �o STD HOOK o (2) #4 CONT /\ // LA W — — / (2) #4 CONT / T o0 3" CLEAR \/ T a) • -L \/% a 3" CLEAR O 00 BEARING j, BEARING' ` O SOIL �/' \ SOIL i ` r 0 \i fi 16" WIDE X 8" DEEP �j�\/j 16" WIDE X 8" DEEP %A CONT FOOTING CONT FOOTING 00 AT CRAWLSPACE AT SLAB = V TYPICAL FOUNDATION WALL N.T.S. 90' STD HOOK INTO INTERSECTING WALL. ALTERNATE EACH BAR WALL SECTION ADDITIONAL CORNER BARS TO ,�.-.�... ... nAA-1I (Ill ll Il Kir TYP CORNER BAR AT WALLS AND STEMS TERMINATE CONT BARS INTO ADJACENT FOOTING 18" MIN WITH 90' STD HOOK- TYP CORNER BAR TYP CONT FOOTING 18 BARS TYP 18 TYP CORNER BAR RESUB AT FOOTINGS Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TYP REINFORCING @ INTERSECTIONS - FOOTINGS & WALL JURISDICTION APPROVAL STAMP BELOW PROJECT #: x23-0801 DATE: 12/08/23 REV DATE: S2 a - TYPICAL DECK FOOTIN, 2'-0"x2'-0"x8" FOOTING #4 EACH WAY @ BOTT( 11 S2 Plan Notes 1. Refer to Architectural drawings for all dimensions. 2. Plan indicates framing at floor level and shear walls below. SYMBOLS 3. All stud walls shall be 2x studs @ 16"oc, uno. 4. All exterior walls shall be SW6 per shear wall schedule, uno. U J -HANGER, MIN FOR MEMBER U.N.O. 5. Floor sheathing shall be 23/32" APA rated sheathing (48/24). Attach sheathing with 10d nails @ 6"oc to all framed panel edges and 12"oc to all intermediate/field framing. Place long - CONCEALED FLANGE HANGER, MIN FOR MEMBER U.N.O. direction of plywood perpendicular to joists direction, stagger rows half the long dimension. 6. Roof sheathing shall be 19/32" APA rated sheathing with 32/16 panel index. Attach 'N ® - BEARING WALL PER GENERAL STRUCTURAL NOTES sheathing with 10d nails @ 6"oc to all framed panel edges and 12"oc to all intermediate/field framing. Use 4'x8' panels with long direction perpendicular to framing. Stagger rows half the $WX - SHEARWALL WITH DESIGNATION PER SHEARWALL SCHEDULE long dimension. 7. Members marked "COLLECTOR" shall receive nailing per detail 5/S2 — — - DIAPHRAGM BOUNDARY 8. All beams shall be flush framed and all headers dropped, uno. Provide Simpson LUS hangers for all 2x joists, typical. Refer to structural general notes for additional connection member 00 O (7)- DIAPHRAGM PROJECTION information. 9. Provide solid bearing under all point loads above. Provide headers over door and window E Q 4--+ openings; (HDR) shall be (2)2x6 minimum. See Detail 2 for beam and header bearing —0 � requirements. Nail multiple studs together per structural general notes. LU 10. Provide H2.5A at each rafter/truss bearing. 11. Overframe where required with 2x4 @ 24" oc U.N.O. by truss manufacturer. Post with 2x4 a--+ Q @ 48" oc max. Brace posts over 6-0" at wide face. (D [� 12. Refer to General Structural Notes and typical details for additional requirements. 0 O 13. (X-X) Callouts are beam member ID's for reference only. Ln Ln E d-) L U T T TD EABCD ETA INSTALL HOT TUB DECK FOUNDATION PLAN WHERE EXIST FOUNDATIOP DEFICIENT, REE PER DETAII 75 a— I L HTT5 I I — — — — — — — — — — — — J FIRST FLOOR WALLS & ROOF FRAM I NG ABOVE urrr, "TT C AT SHEARWALL CALLOUT @ EXISTING WALLS, ADD CONNECTORS AND NAILS AS REQUIRED TO ACHIEVE SPACINGS LISTED IN SW SCHEDULE. ADD PLYWOOD WHERE NOT PRESENT TYPICAL HTT5 RESUB Jun 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT CS16X36 NEW 7 EXISTING WALL a °° r- r- .co QLn Ln Q � 2 00 N (1) o N N W -- = 00 a O00 N X O N m O V Eft lP,p! ,�QS./ ANAL JURISDICTION APPROVAL STAMP BELOW PROJECT #: x23-0801 DATE: 01 /05/24 REV DATE: S3 DO NOT SCALE REFER TO ARCH FOR DIMENSIONS %a' = V-0" DO NOT SCALE REFER TO ARCH FOR DIMENSIONS %4 = 1'-0„