APPROVED FIR RESUB 5-BLD2022-1556+Fire Analysis Stormkeeper Detention Chambers+8.26.2024_3.23.41_PM+4463189E August 26, 2024 via email cburt@southsnofire.org Chris Burt, Deputy Fire Marshall Fire Prevention Services 12425 Meridian Ave. S Everett, WA 98208 275 Grandview Ave. BLD2022-1556 Suite 300 Camp Hill, PA 17011 www.lane-enterprises.com 717.761 •8175 Fax 717. 761 • 5055 Re: Glacier Environmental, 7509 212t' Street SW, Edmonds, WA Dear Mr. Burt: RESUB Approved Aug 27 2024 DFM Chris Burt South County Fire oe es Date: 08/27/2024 08-27-2024 RESUB 5 CIVIL PLAN REVIEW NOTES: APPROVED WITH CONDITION. 1. CIVIL PLANS, C4.21 CROSS SECTIOP DETAILS AND NOTES, STATES 18 INCHES MINIMUM COVER. THE LETTEI SUBMITTED FROM LANE ENTERPRISES WRITTEN ON 08-26-202. STATES 21 INCHES MINIMUM COVER. MINIMUM COVER SHALL BE 21 INCHE: DFM BURT Pursuant to your August 8, 2024 review comments, we have performed (2) finite element analyses (FEA) of the SK75 chamber system for the following loading conditions at a minimum cover of 21 inches: HS-25 Highway Truck 40,000 pound single -axle 20,000 pound 10"x 20" wheel loads 72-inch center -to -center wheel spacing Fire Truck Outrigger 43,000 pounds 24"x24" outrigger distribution area 16-ft center -to -center outrigger loads The analyses were performed using CANDE (Culvert Analysis and Design), a finite element program developed by the Federal Highway Administration. The analyses were evaluated in accordance with the design criteria outlined in ASTM F2787 and Section 12 of the AASHTO LRFD Bridge Design Specifications (as modified for chambers per ASTM F2418). We note that at 21 inches of cover there is no interaction between adjacent wheels or outrigger loads. New York Please let this letter and following pages serve to certify that the SK75 chambers are fully Ballston Spa capable of meeting the above -described loading conditions using standard installation Bath parameters per the SK75 Installation Guide. North Carolina Statesville The analyses assume that (1) the pavement is constructed to support these loads and (2) the system subgrade has sufficient bearing capacity. Pennsylvania Bedford If there are any other questions regarding this matter, please contact me at 717-599-8862. Carlisle King of Prussia Pulaski Shippensburg Very truly yours, Texas Temple Virginia y` Bealeton erome S. Silagyi, P.E. Dublin Chief Engineer Wytheville ESOP p PLASTICS Florida PIPE Alachua INSTITUTE' LANE Metal Products Division • LANE Plastic Pipe Division • LANE Fabricators Division • LANE Technical Coatings Division GLACIER ENVIRONMENTAL, 7509 212T" STREET SW, EDMONDS, WA CTnDNAVrCDCD CV71: CTnDNA\A/ATCD rUAKADCD CVCTCKA ECA Figure 1. HS-25 load centered on center chamber (modeled by the five red shaded round shapes). LRFD STRENGTH-LIN.IT RATIC•S AT STEP 6, FOR PLASTIC GROUP # 1 :)ESIGN-CRITERION CCNTRCL FACTORED FACTORED RATIO NCDE DEY-AND CAPACITY IPALUE NxTERIAL THRUST (psi) 33 -1690W.74 3100.00 0.540w GLOBAL BUCF{LING (psi) 33 -169ow.74 290w°.14 0.560w COMBINED STRAIN (in/in) 20 -0.01144 0.06000 0.191 LRFD SERVICE LG --, PERFORNlidCE AT STEP c, FOR PLASTIC GROUP # 1 N1,XIMUN_-TENSILE STRAIN (in/in).................... 0.003512 RATIO N-,X-TENSILE TC ALLC-WABLE.STRAIN ............ 0.07 PERCENT VERTICAL DEFLECTION ($)................... 1.29 RATIO C•F VERTICAL DEFLECTICii TO ALLOWABLE ........ 0.52 HS-25 CANDE ANALYSIS Attachment to Lane Letter Dated 08/26/2024 GLACIER ENVIRONMENTAL, 7509 212T" STREET SW, EDMONDS, WA CTnonnvrCDCD CV7C CTnDKA\A/ATCD rUAKADCD CVCTrnn CCA Figure 1. Fire truck outrigger load centered on center chamber (modeled by the eleven red shaded round shapes). LRFD STRENGTH -LIMIT R ATIC'S AT STEP c, FGR PLASTIC GROUP # 1 DESIGN -CRITERION C-32TTROL FACTORED FACTORED RATIO NODE DEMAND CAPACITY VALUE MATERIAL THRUST (psi) 34 -1723.23 3100.00 0.556 GLOBAL BUCKLING (psi) 34 -1723.23 290W6.76 0.577 DY-BINED STRAIN (in/in) 33 -0.01143 0.06000 0.190 LRFD SERVICE LOAD PERFORMANCE AT STEP 6, FOR PLASTIC GROUP # 1 MAXIMUM -TENSILE STRAIN (in/in).................... 0.004042 RATIO YAK -TENSILE TC ALLOWABLE.STRAIN ............ 0.08 PERCENT �,ERTICAL DEFLECTION (%)................... 1.61 RATIO CF TJERTI A.L DEFLECTION TO ALLC-wABLE ........ 0.64 FIRE TRUCK OUTRIGGER CANDE ANALYSIS Attachment to Lane Letter Dated 08/26/2024