Loading...
REVIEWED RESUB 1-BLD2022-1542+BUILDING ENVELOPE +8.5.2024_12.00.59_PM+4421223ENVELOPE COMPLIANCE SUMMARY ............................................. REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT'- .............................................. 2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project & Applicant Information Project Title Glacier Environmental Services Warehouse Building - 2018 WSEC For Building Department Use: Date, Aug 05, 2024 RES U 6 Aug 05 2024 BLD2022-1542 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT Project Address 7509 212th Street SW Edmonds, WA 98026 Applicant Name Theresa Greene Applicant Phone 425-830-3245 Applicant Email tg.architect@comcast.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type(s) Warehouse, General Storage Office, Other Building Cond. Floor Area 4,000 Project Cond. Floor Area 4,000 Project Scope New Building Space Conditioning Categories Fully Conditioned Floors Above Grade 1 Compliance Method General Prescriptive Envelope Project Description 800 s.f. portion of Warehouse Building to be Conditioned for Offices Envelope Compliance Scope and Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification New Building Fully Conditioned Prescriptive 14.64% / 0% None selected No alternates selected COMPLIES Method Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments oject Title Glacier Environmental Services Warehouse Building - 2018 WSEC ate Aug 05, 2024 Scope & Space Conditioning NEW BUIL - LY CONDITION Compliance Verificatio Window -to -wall Ratio 14.64% Skylight -to -roof -ratio 0% 1 Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous (%penetration) 2nd Layer U-Factor (MB Roof) Net Area (SF) Metal building (purlins) A2.3 Table C402.1.4 Exterior R-25 I (< 0.04%) R-11 U-0.031 800 Thermal Spacer Block R-Value: R-3.5 Is liner system included?: Yes U-Factor Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Metal building (girts) Levels of Insulation, Sheet A2.3, Building Sections A4.1 Table C402.1.2 Exterior R-21 R-0 (< 0.04%) U-0.052 2,117 Which insulation code target does wall comply with?: Wall Assembly U-factor U-Factor Source: U-Factor Source Description: Framing Depth: Framing Spacing: Is this assembly exterior or interior?: Exterior Slab -on -grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab Levels of Insulation, Sheet A2.3 I Table C402.1.3 At grade level R-10 R-10 280 Slab Insulation Method: Fully insulated slab (slab edge and underneath) F-Factor Source: F-Factor Source Description: Fenestration & Opaque Door Assemblies Insulation R-Values Vertical Fenestration Location in Documents Assembly ID Assembly Location Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Fixed - Class AW or site built Levels of Insulation, Sheet A2.3, Schedules, Sheet A5.1 Table C402.4 Exterior I PF < 0.2 SHGC-0.38 U-0.38 363 U-Factor & SHGC Source: U-Factor Source Description: Is this assembly exterior or interior?: Exterior