Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB 1-BLD2022-1542+LIGHTING FORM+8.5.2024_12.00.59_PM+4421225
2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: ©2024 NEEA, All rights reserved Project Title Glacier Environmental Services Warehouse Building - 2018 WSEC For Building Department Use: Date. Aug 05, 2024 7509 212th Street SW REU B Project & Applicant Project Address Edmonds, WA 98026 ............................................. REVIEWED Aug 05 2024 Applicant Name Theresa Greene Information By BLD2022-1542 CITY OF EDMONDS E CITY OF EDMONDS SERVICES BUILDING DEPARTMENT E DE DEPARTMENT DEPARTMENT Applicant Phone 425-830-3245 Applicant Email tg.architect@comcast.net ............................................... For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Warehouse, General Storage Office, Other Building Cond. Floor Area 4,000 New Building or Project Cond. Floor Area 4,000 General Project Types New Building Addition Interior Lighting Lihtin gg AlterationExterior LihtinScoe gg p Floors Above Grade 1 Compliance Method General Prescriptive Lighting Scope Lighting Project Description New 1-Story Warehouse Building Lighting Compliance Project Type Interior / Exterior (Interior includes both interior Luminaire Replacement Scope Compliance Method LPA Calculation Adjustment Compliance Verification Scope & parking New Building Interior Lighting Space by space No Calculation Adjustments selected COMPLIES and Method New Building Exterior Lighting Not applicable to exterior COMPLIES 7Lighti,g itle Glacier Environmental Services Warehouse Building - 2018 WSEC a Aug 05, 2 Calculation NEW BUILDING - INTERIOR LIGHTING Compliance Verification COMPLIES d Space by space LPA Calculation Adjustment none Interior Lighting Power Allowance - Space by Space General Space Type Specific Space Type Gross Interior Area (SF) LPA (Watts/SF) Total Watts Allowed (SF x LPA x 1) Total Proposed Watts (LPD + Display LPD) Compliance Status Office Open plan 800 0.61 488 Warehouse/storage area Smaller hand -carried items 3,200 0.69 2,208 Proposed Total LPD 1,797 Totals 1 2,696 1 1,797 1 COMPLIES Proposed Lighting Power Density Fixture Type Fixture ID Quantity of Fixtures (#F) Watts or Wattage Limit per Fixture (WpF) Total Linear Feet (LF) Watts per Linear Foot (WpLF) Total Watts Proposed (#F x WpF) or (LF x WpLF) Individual Fixtures Troffer 2X4 LED Recessed 6 53 318 Recessed downlight 6" Recessed Can Light 2 17 34 Suspended 4' Suspended Warehouse Lighting 24 50 1,200 Suspended Pendant Fixture 4 50 200 Wall -mounted Restroom Lav Fixture l 36 36 Wall -mounted Exit Sign w/90 minute Battery Backup 1 3 3 Other fixture type Exit Sign w/90 minute Battery Backup 2 3 6 Proposed Total LPD 1,797 Project Title Glacier Environmental Services Warehouse Building - 2018 WSEC Date Aug 05, 2024 Proposed Fixtures Details NEW BUILDING - INTERIOR LIGHTING Fixture Type/Application Fixture ID Location in Documents Lamp Type New or Existing -to -Remain Individual Fixtures Troffer 2X4 LED Recessed A2.2 LED New Fixture Description: 2X4 LED Recessed Troffer Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Recessed downlight 6" Recessed Can Light A2.2 LED New Fixture Description: 6" Recessed Can Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended 4' Suspended Warehouse Lighting I A2.2 LED New Fixture Description: 4' Suspended Warehouse Lighting Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Suspended Pendant Fixture A2.2 LED New Fixture Description: Are these fixtures located within a daylight zone?: Yes, controls provided Daylight zone location(s): Sidelit daylight zones (primary and/or secondary) Dimming method: Continuous dimming Do these fixtures require specific application lighting controls?: None required Wall -mounted Restroom Lav Fixture A2.2 LED New Fixture Description: Restroom Lav fixture Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Wall -mounted Exit Sign w/90 minute Battery Backup A2.2 LED New Fixture Description: Exit Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Other fixture type Exit Sign w/90 minute Battery Backup A2.2 LED New Fixture Description: Exit Light Are these fixtures located within a daylight zone?: No Do these fixtures require specific application lighting controls?: None required Project Title Glacier Environmental Services Warehouse Building - 2018 WSEC ate Aug 05, 2024 Lighting Power Calculation NEW BUILDING - EXTERIOR LIGHTING Compliance Verification COMPLIES Exterior Lighting Zone ZONE 3 Base Site Allowance 500 Exterior Tradable Lighting Power Allowance Exterior Surface Surface Sub -Type Surface LPA Linear LPA Total Watts Allowed (LPAx SF) or Total Compliance Status Area (SF) (Watts/SF) Feet (LF) (Watts/LF) (LPA x LF) Proposed Watts Building grounds Landscaping 800 0.04 32 Building grounds Walkways < 10 feet wide 160 0.60 96 Base Site Allowance 1 500 Totals 1 628 1 330 COMPLIES Proposed Tradable Lighting Power Density Watts or Total Watts Fixture Type Fixture ID Exterior Surface Type Quantity of Wattage Limit Total Linear Watts per Linear Proposed Fixtures (#F) per Fixture Feet (LF) Foot (WpLF) (#F x WpF) or (WpF) (LF x WpLF) Individual Fixtures Wall-mountedl Exterior Wall -Pack Building grounds - Landscaping 2 30 60 Wall-mountedl Exterior Wall -Pack Building grounds - Walkways < 10 feet wide 9 30 270 Proposed Total LPD 330