Loading...
REVIEWED BLD2022-1541+Energy_Code_Sheet_or_Envelope_Summary+11.11.2022_10.12.16_AM+32157852018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: 02022 NEEA, All rights reserved Project & Applicant Information Project Title Glacier Environmental Services Office Building - 2018 WSEC For Building Department Use, I Date: Nov 11, 2022 REVIEWED CITY OF EDMONDS €auaDINCDEanRrmENr? RECEIVED ........ ............ . BLD2022-1541 Nov 152022 DE' o°M H° S-- Project AddressBY 7509 212th Street SW Edmonds, WA 98026 Applicant Name Theresa Greene Applicant Phone 425-830-3245 Applicant Email tg.architect@comcast.net For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com General Occupancy All Commercial General Building Use Type Office, Other Building Cond. Floor Area 4,600 Project Scope New Building Space Conditioning Categories Fully Conditioned Project Cond. Floor Area 4,600 Floors Above Grade 2 Compliance Method Compliance Method I - General Envelope Project Description New 2-Story Office Building Envelope Compliance Scope Scope Space Conditioning Category Compliance Method WWR/SRR per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification and Method New Building Fully Conditioned Prescriptive 35.06% / 0% None selected No alternates selected COMPLIES Air Barrier Testing I Air barrier testing included in project scope I Air Barrier Comments Project Title Glacier Environmental Services Office Building - 2018 WSEC Date Nov 11, 2022 Scope & Space Conditioning NEW BUILDING - FULLY CONDITIONED Compliance Verification COMPLIES Window -to -wall Ratio 1 35.06% Skylight -to -roof -ratio 0% 1 Vertical Fenestration Alternate No alternates selected Opaque Envelope Assemblies Insulation R-Values Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity o Continuous ( /o penetration) 2nd Layer (MB Roof) U-Factor Net Area (SF) Insulation entirely above deck Levels of Insulation, Sheet A2.12, Section 6/A4.2 Table C402.1.4 Exterior I R-38 (< 0.04%) U-0.027 2,748 U-Factor Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Walls Location in Documents Assembly ID Assembly Location Cavity Continuous (% penetration) Insulated Wall Furring U-Factor Net Area (SF) Wood -framed and other -Commercial Levels of Insulation, Sheet A2.12, Wall Sections, Sheet A4.2 Table C402.1.2 Exterior R-21 R-0 (< 0.04%) U-0.054 2,500 Which insulation code target does wall comply with?: R-21 Cavity + Intermediate Framing U-Factor Source: WSEC Appendix A U-Factor Source Description: Wall Framing Type (Standard, Inter., Advanced): Intermediate Framing Depth: 2x6 Framing Spacing: 16" o.c. Is this assembly exterior or interior?: Exterior Slab -on -grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter Length (SF) Unheated slab Levels of Insulation, Sheet A2.12, Wall Sections, Sheet A4.2 Table C402.1.3 I At grade level R-10 I R-0 F-0.54 212 Slab Insulation Method: 2 ft horizontal (no slab edge insulation) F-Factor Source: WSEC Appendix A F-Factor Source Description: Fenestration & Opaque Door Assemblies or Insulation R-Values Vertical Fenestration Location in Documents Assembly ID Assembly Location Orientation Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Fixed - Class AW or site built I Levels of Insulation, Sheet A2.12, Schedules, Sheet A5.2 Table C402.4 I Exterior South/East/West Facing I PF < 0.2 1 SHGC-0.38 U-0.38 1,102 U-Factor & SHGC Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Fixed - Class AW or site built Levels of Insulation, Sheet A2.12, Schedules, Sheet A5.2 Table C402.4 Exterior North Facing PF < 0.2 SHGC-0.51 I U-0.38 128 U-Factor & SHGC Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Glazed Doors Location in Documents Assembly H) Assemble Location Orientation Shading (PF) Fenestration SHGC Fenestration U-Factor Rough Opening (SF) Swinging entrance door Levels of Insulation, Sheet A2.12, Schedules, Sheet A5.2 Table C402.4 Exterior South/East/West Facing I PF < 0.2 SHGC-0.38 U-0.6 120 U-Factor & SHGC Source: WSEC Appendix A U-Factor Source Description: Is this assembly exterior or interior?: Exterior Is this a public entrance door?: Yes Door enclosed within a vestibule?: No vestibule