Loading...
REV5 APPROVED BLD BLD2023-0103+NEW-Architectural_Plan+8.27.2024_11.50.12_AM+4465133�. REMOVED REMOVED WINDOW WINDOW 30' EXISTING RESIDENCE MAIN LEVEL DEMOLITION FLOOR PLAN SCALE: 1 /4" = 1'-0" SYMBOLS: C I AREA OF REMOVED MAIN LEVEL FLOOR EXISTING MAIN LEVEL FLOOR TO REMAIN LINE OF EXISTING WALLS THAT WERE REMOVED FOOTPRINT OF EXISTING MAIN LEVEL FLOOR M RTH ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ r ■ ■ THE FOLLOWING DOCUMENTATION SHALL BE : AVAILABLE ON SITE FOR THE BUILDING INSPECTOR: �X COE APPROVED ARCHITECTURAL PLAN SET U COE APPROVED STRUCTURAL PLAN SET n COE REVIEWED CALCULATION PACKET ENERGY CREDIT WORKSHEET SITE PLAN CIVIL PLAN ; CITY OF EDMONDS BUILDING DEPARTMENT 2021 ; REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION BUILDING OFFICIAL Sep 04 2024 APPROVED DATE APPROVED ALL WORK SUBJECT PLANS MUST BE TO FIELD ON JOB SITE INSPECTION FOR CODE COMPLIANCE RESUB Aug 28 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVISION Aug 28 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT H LL. Cn Z O � O LU U w CD LU 0 LLJ C/) cn C:) > Q w J Q � (D w o (~i) w N � w c qlzl- X 0 W N W \ II A I1� ►IA�� 1 '_ V ARCHITECT 39TH AVENUE SO. SEATTLE, WA 98118 1• 632-0287 CONTRACTOR NOTICE: CONTRACTOR (SUB- CONTRACTORS) SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMMISIONS, OR DISCREPENCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. THE CONTRACTOR (SUB -CONTRACTORS) SHALL BE RESPONSIBLE TO VERIFY THAT ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND ORDINANCES AND SHALL NOTIFY THE ARCHITECT OF ANY DEVIATION. PROJECT NO. DATE: 6/10/2022 REVISIONS: 6/20/2022 8/27/2024 EXISTING MAINLEVEL FLOOR PLAN A2. 01 a 0 M 30, .. .. . .. .'..:': ...... ...... :...............:::::::::::::::::::::::... .. ....... .. ...................................................... J ::': Q .. 2' X 2'NEW FOOTING::p : NEW POST ::::;:::::::;:::::: o: o: L. :::: z ::: EXISTING SLAB ON GRADE )OR ova ::: :.0-'::':.... ::.:: :I.. s �a:;:E:a:�:�: ::::: .. I........................'.'.':.'.':.'.'.'.':.'.':.'.'.'.':.'......':. .:...:: ". ': : ":.::.'.':.'.'.'.':.'.':.'.'.'.':.'.':.'.'.'.':.'.':.'.'.'.':.'.':.'.'.'.':.'.':.'.'.'.'. .. ... ... .. ......................................... 4...11..................................................... ............................................... 1.a -( .:...... fV.� .:F: REMOVE EXISTING WINDOW & REINSTALL 30, EXISTING RESIDENCE ., J. �;3:- .. ...................hh 2.................................... rvinTiwi� r�� �w ir�nT��wi CJ�IJ I IIVl7 4_i�iv i ii�v i vvi�vi--� i ivi� WINDOW TO REMAIN RI E; R --MOVE LISTING INDOW -LEC. METER EPLACE KISTING IINDOW 0 BASEMENT FLOOR PLAN DEMOLITION PARTIAL CMU WALL TO REMAIN DEMOLISH PARTIAL CMU WALL CONCRETE WALL TO REMAIN BASEMENT CMU FLOOR PLAN DEMOLITION SCALE: 1/4" = 1'-0" NORTH/) SCALE: 1/4" = 1'-0" SQUARE FOOTAGE OF EXISTING BASEMENT LEVEL INCLUDING FOUNDATION: 930 SQ. FT. SQUARE FOOTAGE OF SLAB AT BASEMENT LEVEL (REFER TO HATCHED AREA) : 851 SQ. FT. LINEAL FEET OF EXISTING FOUNDATION AND FOOTING: 55' - 4" LINEAL FEET OF EXISTING FOUNDATION AND FOOTING TO BE REMOVED AND REPLACED WITH NEW FOUNDATION AND FOOTING: 61'- 4" C ....:..., .: NEW FOUNDATION & FOOTING EXISTING FOUNDATION FOOTPRINT OF EXISTING BASEMENT LINE OF EXISTING WALLS TO BE REMOVED ALL EXISTING ELECTRICAL / PLUMBING SHALL EITHER BE REUSED IN ITS CURRENT LOCATION OR BE LEFT ABANDONED IN THE WALLS AND FLOORS ALL EXISTING SLAB FLOOR AND PLUMBING UNDER THE SLAB SHALL REMAIN .................... PARTIAL CMU WALLS TO BE DEMOLISHED PARTIAL CMU WALL TO REMAIN CONCRETE WALL TO REMAIN RESUB Aug 28 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT RTH REVISION Aug 28 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT H LL. Cn Z O � O LU U w CD LU 0 LLJ C/) cn C:) > Q w J Q � (D w o c~w N � X w cy-) 0 W N W P, 11108"S HJERT-BERNARDI ARCHITECT 9228 39TH SEATTLE, WA • • 1• 632-0287 CONTRACTOR NOTICE: CONTRACTOR (SUB- CONTRACTORS) SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMMISIONS, OR DISCREPENCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. THE CONTRACTOR (SUB -CONTRACTORS) SHALL BE RESPONSIBLE TO VERIFY THAT ALL WORK SHALL COMPLY WITH APPLICABLE CODES AND ORDINANCES AND SHALL NOTIFY THE ARCHITECT OF ANY DEVIATION. PROJECT NO. DATE: 6/10/2022 REVISIONS: 6/20/2022 8/27/2024 EXISTING BASEMENT FLOOR PLAN A2.02a