Loading...
REV1 APPROVED BLD2022-0080+FLOOR PLAN+3.8.2023_9.02.55_AM+3408243MECHANICAL & ENERGY NOTES 1. ALL MECHANICAL WORK TO BE DESIGNED BY SUBCONTRACTOR AND SHALL COMPLY WITH ALL APPLICABLE CODES AND ORDINANCES. 2. THE MECHANICAL WORK MUST ADHERE TO ALL REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. 3. VENTILATION OF ALL AREAS SHALL BE IN CONFORMANCE WITH WAC 51-11 AND WAC 51-13, 2018 IRC, CHAPTER 15, TABLES M1507.3.30) & M1507.3.3(2) 4. ALL EXTERIOR JOINTS AROUND WINDOWS AND DOORS, OPENINGS BETWEEN WALLS AND ROOF OR FOUNDATIONS, OPENINGS AT PENETRATIONS AND ALL OTHER SUCH OPENINGS SHALL BE SEALED, CAULKED, OR HAVE A GASKET OR WEATHER STRIPPING TO LIMIT AIR LEAKAGE PER THE 2018 WSEC. 2018 WSEC PRESCRIPTIVE REQUIREMENTS (ZONE 4C, PRESCRIPTIVE OPTION 3): CREDITS REQUIRED: 3.0 CREDITS FOR SMALL DWELLING UNIT. THE FOLLOWING CREDITS ARE PURSUED: FUEL NORMALIZATION OPTION 4: DHP WITH ZONAL ELECTRIC RESISTANCE (0.5 CREDIT) OPTION 1.3: EFFICIENT BUILDING ENVELOPE (0.5 CREDIT) OPTION 3.4: HIGH EFFICIENCY HVAC EQUIPMENT (1.5 CREDITS) OPTION 5.2: EFFICIENT WATER HEATING (0.5 CREDIT) INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT PER 2018 WSEC TABLE R402.1.1 AND OPTION 1.3 FLOORS CEILINGS (VAULTED) CEILINGS EXTERIOR WALLS (FRAMED 16" O.C.) BELOW GRADE WALLS, INT. INSUL. SLAB ON AND BELOW GRADE GLAZING - VERTICAL GLAZING - OVERHEAD GLAZING AREA DOORS* DUCT INSULATION HOT WATER PIPE WINDOW AND DOOR HEADERS R-38 R-38 R-49 (R-38 ADV.) R-21 R-21 + R-5 C.I. R-10 PERIMETER T.B. AND UNDER ENTIRE SLAB U-0.28 MAX. U-0.50 MAX. UNLIMITED 0.30 MAX w/ 1 EXEMPT R-8 R-4 R-10 *EXTERIOR DOORS ARE TO BE 1-%" SOLID CORE WITH FULL WEATHER STRIP AND TRESHOLD. ALL GLAZING IN EXTERIOR DOORS IS TO BE DOUBLE GLAZED WITH SAFETY GLASS. 5. CREDIT OPTION 3.4: DUCTLESS SPLIT SYSTEM HEAT PUMPS WITH ZONAL ELECTRIC RESISTANCE HEATING. SPLIT HEAT PUMP SYSTEMS SHALL BE DESIGN -BUILD IN THE LARGEST HEATING ZONE AND HAVE A MIN. HSPF OF 10. 6. CREDIT OPTION 5.2: WATER HEATING SYSTEM SHALL BE A GAS -FIRED WATER HEATER WITH A MIN. EF OF 0.80. 7. GLAZING AREA ALLOWED IS UNLIMITED, GROUP R-3 ONLY. ALL EXTERIOR GLAZING SHALL BE DOUBLE GLAZED (MIN.). 8. ALL FURTHER CALCULATIONS ARE TO BE PROVIDED BY THE MECHANICAL CONTRACTOR PRIOR TO APPLYING FOR A MECHANICAL PERMIT. 9. HEATING DESIGN TEMPERATURES: (PER WA STATE ENERGY CODE) HEATING: 70 DEGREES INSIDE AND 46 DEGREES OUTSIDE. 10. PROVIDE DUCT INSULATION AS REQUIRED BY WSEC R403.2.1. 11. SOURCE SPECIFIC VENTILATION. VENTILATION (EXHAUST) SHALL BE PROVIDED IN BATHROOMS, KITCHENS, LAUNDRY ROOMS, POOL ROOMS AS WELL AS IN OTHER ROOMS WHERE EXCESS WATER VAPOR OR COOKING ODOR ARE PRODUCED, AS REQUIRED BY THE 2018 IRC, CH.15. PER TABLE M1507.4. 12. A WHOLE HOUSE VENTILATION SYSTEM SHALL BE INSTALLED OF EITHER INTERMITTENT OR CONTINUOUS OPERATION AS REQUIRED BY THE 2018 IRC, CH.15. 13. DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR AND HOMEOWNER PRIOR TO AN APPROVED FINAL INSPECTION PER WSEC 101.4.3.1 & 403.2 A SIGNED AFFIDAVIT DOCUMENTING THE DUCT LEAKAGE TEST RESULTS SHALL BE PROVIDED TO THE BUILDING INSPECTOR PRIOR TO AN APPROVED FINAL INSPECTION. 14. A RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE COMPLYING WITH WSEC 401.3 IS REQUIRED TO BE COMPLETED BY THE DESIGN PROFESSIONAL OR BUILDER AND PERMANENTLY POSTED WITHIN 3' OF THE ELECTRICAL PANEL PRIOR TO FINAL INSPECTION. 15. INSULATION INSTALLERS SHALL PROVIDE A CERTIFICATION LISTING THE TYPE, MANUFACTURER AND R-VALUE OF INSULATION INSTALLED IN EACH ELEMENT OF THE BUILDING THERMAL ENVELOPE (WSEC R303.1.1) 16. THE BUILDING OFFICIAL, UPON NOTIFICATION, SHALL MAKE A WALL INSULATION INSPECTION IN ADDITION TO THOSE INSPECTIONS REQUIRED IN SECTION R109 OF THE IRC. THIS INSPECTION SHALL BE MADE AFTER ALL WALL AND CAVITY INSULATION IS IN PLACE AND PRIOR TO COVER (WSEC R104.2.1) 17. A BAFFLE SHALL BE INSTALLED ADJACENT TO SOFFIT AND EAVE VENTS FOR AIR PERMEABLE INSULATIONS IN VENTED ATTICS. (WSEC R402.2.3) 18. ACCESS HATCHES FROM CONDITIONED SPACES TO UNCONDITIONED SPACES SHALL BE WEATHER STRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION ON THE SURROUNDING SURFACES (WSEC R402.2.4) 19. THE BUILDING OR DWELLING UNIT SHALL BE TESTED AND VERIFIED AS HAVING AN AIR LEAKAGE RATE OF NOT EXCEEDING 5 AIR CHANGES PER HOUR. TESTING SHALL COMPLY WITH SECTION R402.4.1.2 OF THE 2018 WSEC. TEST RESULTS SHALL BE POSTED ON THE RESIDENTIAL ENERGY COMPLIANCE CERTIFICATE (SEC 105.4) 20. EACH DWELLING UNIT IS REQUIRED TO BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR THE REGULATION OF TEMPERATURE PER 2018 WSEC 403.1. 21. MINIMUM 75% OF ALL INTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINAIRES. 22. ALL EXTERIOR LIGHTING SHALL BE HIGH EFFICACY LUMINAIRES. 23. PER 2018 WSEC R402.2.7 FLOOR INSULATION SHALL BE INSTALLED TO MAINTAIN PERMANENT CONTACT WITH THE UNDERSIDE OF THE SUB -FLOOR DECKING. INSULATION SUPPORTS SHALL BE INSTALLED SO SPACING IS NO MORE THAN 24" ON CENTER. FOUNDATION VENTS SHALL BE PLACED SO THAT THE TOP OF THE VENT IS BELOW THE LOWER SURFACE OF THE FLOOR INSULATION. 24. U-FACTORS OF FENESTRATION PRODUCTS (WINDOWS, DOORS AND SKYLIGHTS) SHALL BE DETERMINED IN ACCORDANCE WITH NFRC 100. PRODUCTS SHALL BE LABELED AND CERTIFIED BY THE MFR. The following documentation shall be available on site for the building inspector: ■ ■ 0 COE APPROVED ARCHITECTURAL PLAN SET ' ; ❑ COE APPROVED STRUCTURAL PLAN SET ❑ COE REVIEWED CALCULATION PACKET . 0 ENERGY CREDIT WORKSHEET ■ ; ❑ SITE PLAN ; ■ n CIVIL PLAN ■❑ F] ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 1 WHOLE -HOUSE VENTILATION SYSTEM M1507.3.1 SYSTEM DESIGN. EACH DWELLING UNIT OR GUEST ROOM SHALL BE EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M1507.3.4. M1507.3.5. M1507.3.6, OR M1507.3.7. COMPLIANCE IS ALSO PERMITTED TO BE DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL CODE. M1507.3.2 CONTROL AND OPERATION. 1. CONTROLS FOR ALL VENTILATION SYSTEMS SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. 2. LOCAL EXHAUST SYSTEMS SHALL BE CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER APPROVED MEANS. 3. CONTINUOUS WHOLE -HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY. EXHAUST FANS, FORCED -AIR SYSTEM FANS, OR SUPPLY FANS SHALL BE EQUIPPED WITH "FAN ON" AS OVERRIDE CONTROLS. CONTROLS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." 4. INTERMITTENT WHOLE -HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING INTERMITTENTLY AND CONTINUOUSLY. THE VENTILATION RATE SHALL BE ADJUSTED ACCORDING TO THE EXCEPTION IN SECTION M1507.3.3. THE SYSTEM SHALL BE DESIGNED TO OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL TIMER INSTALLED. THE SYSTEM SHALL OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. THE SYSTEM SHALL HAVE A MANUAL CONTROL AND AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. AT THE TIME OF FINAL INSPECTION, THE AUTOMATIC CONTROL SHALL BE SET TO OPERATE ACCORDING TO THE SCHEDULE USED TO CALCULATE THE WHOLE HOUSE FAN SIZING. A LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)." M1507.3.2.1 OPERATING INSTRUCTIONS INSTALLERS SHALL PROVIDE THE MANUFACTURER'S INSTALLATION, OPERATING INSTRUCTIONS, AND A WHOLE -HOUSE VENTILATION SYSTEM OPERATION DESCRIPTION. M1507.3.3 MECHANICAL VENTILATION RATE. THE WHOLE HOUSE MECHANICAL VENTILATION SYSTEM SHALL PROVIDE OUTDOOR AIR TO EACH HABITABLE SPACE AT A CONTINUOUS RATE OF NOT LESS THAN THAT DETERMINED IN ACCORDANCE WITH TABLE M1507.3.30). TABLE M1507.3.30) - MINIMUM VENTILATION RATES (CONTINUOUSLY OPERATING SYSTEMS) BEDROOMS SQ FT 0-1 2-3 4-5 6-7 7+ <1500 30 45 60 75 90 1501-3000 45 60 75 90 105 3001-4500 60 75 90 105 120 4501-6000 75 90 105 120 135 6001-7500 90 105 120 135 150 >7501 105 120 135 150 165 M1507.3.3 INTERMITTENTLY OPERATING VENTILATION SYSTEMS. THE WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM IS PERMITTED TO OPERATE INTERMITTENTLY WHERE THE SYSTEM HAS CONTROLS THAT ENABLE OPERATION FOR NOT LESS THAN 25% OF EACH 4-HOUR SEGMENT AND THE VENTILATION RATE PRESCRIBED IN TABLE M1507.3.30) IS MULTIPLIED BY THE FACTOR DETERMINED IN ACCORDANCE WITH TABLE M1507.3.3(2). TABLE M1507.3.3(2) - VENTILATION RATE FACTORS (INTERMITTENTLY OPERATING SYSTEM) RUN TIME (4HR SEGMENT) 25% 33% 50% 66% 75% 100% FACTOR 4 3 2 1.5 1.3 1.0 VENTILATION CALC IF RUN CONTINUOUSLY: 45 CFM IF RUN INTERMITTENTLY: 25%: 180 CFM, 33%: 135 CFM, 50%: 90 CFM, 66%: 68 CFM, 75%: 59 CFM PREFERRED WHOLE -HOUSE VENTILATION OPTION M1507.3.4 WHOLE -HOUSE VENTILATION WITH EXHAUST FANS THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS FOR INTERMITTENT WHOLE HOUSE VENTILATION SYSTEMS WITH EXHAUST FANS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A WHOLE HOUSE VENTILATION SYSTEM. CONTINUOUSLY OPERATING EXHAUST FAN WHOLE -HOUSE SYSTEMS SHALL PROVIDE OUTDOOR AIR AT THE FOLLOWING RATES CALCULATED USING TABLES M1507.3.30) AND M1507.3.3(2): 60 CFM (CONTINUOUS) INTERMITTENTLY OPERATING EXHAUST FAN WHOLE -HOUSE SYSTEMS SHALL PROVIDE OUTDOOR AIR AT THE FOLLOWING RATES CALCULATED USING THE FACTOR TABLE (M1507.3.3(2)): EACH UNIT: 240 CFM (25%). 180 CFM (33%). 120 CFM (50%). 90 CFM (66%). 78 CFM (75%) SEE FLOOR PLANS FOR FAN LOCATIONS. OUTDOOR AIR SHALL BE SUPPLIED TO EACH HABITABLE SPACE. WHERE OUTDOOR AIR SUPPLY INTAKES ARE SEPARATED FROM EXHAUST VENTS BY DOORS, MEANS SHALL BE PROVIDED TO ENSURE AIRFLOW TO ALL SEPARATED HABITABLE SPACES BY INSTALLING DISTRIBUTION DUCTS, INSTALLED GRILLES, TRANSOMS, DOORS UNDERCUT TO A MINIMUM OF z INCH ABOVE THE SURFACE OF THE FINISH FLOOR COVERING, OR OTHER SIMILAR MEASURES WHERE PERMITTED BY THE INTERNATIONAL BUILDING CODE. M1507.3.4.4 OUTDOOR AIR INLETS. INLETS SHALL BE SCREENED OR OTHERWISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL. OUTDOOR AIR INLETS SHALL BE LOCATED SO AS TO NOT TAKE AIR FROM THE FOLLOWING AREAS: 1. CLOSER THAN 10 FEET FROM AN APPLIANCE VENT OUTLET, UNLESS SUCH VENT OUTLET IS 3 FEET ABOVE THE OUTDOOR AIR INLET. 2. WHERE IT WILL PICK-UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE VAPORS. 3. A HAZARDOUS OR UNSANITARY LOCATION. 4. A ROOM OR SPACE HAVING ANY FUEL- BURNING APPLIANCES THEREIN. 5. CLOSER THAT 10 FEET FROM A VENT OPENING OF A PLUMBING DRAINAGE SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3 FEET ABOVE THE AIR INLET. 6. ATTIC, CRAWL SPACES OR GARAGES. M1506.2 EXHAUST OPENINGS. ALL EXHAUST OPENINGS SHALL COMPLY WITH 2O18 IRC SECTIONS R303.5.2 & R303.6. 4PPRUt.. PLANS MUST 6_ ON JOB SITE ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE WALL ASSEMBLIES WALL: TYP. EXTERIOR W1 (E) SIDING AND INFILTRATION BARRIER TO REMAIN (E) SHEATHING TO REMAIN (E) 2x FRAMING TO REMAIN R-21 MIN. BATT INSULATION %" GWB WALL: GARAGE/DWELLING SEPARATION W2 Y" TYPE X GWB (GARAGE SIDE) (E) 2x4 FRAMING TO REMAIN R-21 MIN. RIGID INSULATION %" GWB (DWELLING SIDE) (E) WINDOW IN UNCONDITIONED SPACE TO REMAIN (E) GARAGE WALLS TO REMAIN ENERGY CODE PLAN SCALE: 1 /4" = 1 '-0" FLOOR ASSEMBLIES FLOOR: TYP. FRAMED FLOOR F1 FINISH FLOOR PER OWNER (E) SHEATHING TO REMAIN (E) FRAMING TO REMAIN R-38 MIN. BATT INSULATION VAPOR BARRIER ROOF/CEILING ASSEMBLIES ROOF: TYPICAL FRAMED (E) ROOFING AND UNDERLAYMENT TO REMAIN (E) SHEATHING TO REMAIN (E) FRAMING TO REMAIN 1" MIN. AIR GAP R-49 MIN. BATT INSULATION %" GWB INSTALL (N) MINI -SPLIT COMPRESSOR W/ MIN. HSPF OF 10. REPLACE ALL WINDOWS IN CONDITIONED SPACE PER SCHEDULE ON SHEET 0.1. (TYP.) N TYP. BLD2022-0080 6\ 0 4 8 16 1 /4" = 1 '-0" CITIZEN DESIGN TF TF ON O 00 LU Z O LU HF-: I.0 w O~ SeLU w J O W -1 O C'M City of EDMONDS Permit Revision March 8, 2023 REVISION Mar 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FOR PLANNING DEPT USE ONLY PLANS AND ASSEMBLIES SCALE: AS NOTED