REV1 APPROVED BLD2022-0080-ENERGY FORMPROJECT INFORMATION 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Version 1 0 These requirements apply to all IRC building types, including detached one- and two-family dwellings and multiple single-family dwellings (townhouses). Project Information Contact Information Bukowski Remodel and Repair Jacob Young 304Dalay SL Edmonds WA 98020 young )collaborativeco,com Instructions: This single-family project will use the requirements of the Prescriptive Path below and incorporate the minimum values listed. Based on the size of the structure, the appropriate number of additional credits are checked as chosen by the permit applicant. Provide all information from the following tables as building permit drawings: Table R402.1- Insulation and Fenestration Requirements by Component, Table R406.2 - Fuel Normalization Credits and 406.3 - Energy Credits. IAuthorized Representative I (Date All Climate Zones able R402.1.1 R-Value ` U-Factor ° Fenestration U-Factorh n/a 0.30 Skylight U-Factor b n/a 0.50 Glazed Fenestration SHGC h,` n/a nja Ceiling ` 49 0,026 Wood Frame Wall °" 21 int 0.056 Floor 30 0.029 Below Grade Wall `-h 10/15/21 int+TB 0,042 51ab • R-Value & Depth 10, 2 ft nla R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity that is less a than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-valuespecified in the table. b The fenestration U-factor column excludes skylights. "10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity Insulation plus a thermal break between the slab and the basement wall at c the interior of the basement wall. "10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full Insulation depth e extends over the top plate of the exterior wall. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for 9 climate zone 5 of ICC 400. Int. (intermediate framing) denotes framing and insulation as described in Section A103.2.2 including standard h framing 16 inches on center, 78% of the wall cavity Insulated and headers insulated with a minimum of R-10 insulation. Presmptive Path - Single Family 2018 Washington State Energy Code-R 1 REVISED PLAN APPROVED CITY OF EDMONDS BUILDING DIVISION Eric BUILDING OFFICIAL Mar 15 2023 APPROVED DATE APPROVED PLANS MUST BE ON JOB SITE The following documentation shall be available on ' site for the building inspector: Q COE APPROVED ARCHITECTURAL PLAN SET ' ; ❑ COE APPROVED STRUCTURAL PLAN SET COE REVIEWED CALCULATION PACKET Fx] ENERGY CREDIT WORKSHEET ' ❑ SITE PLAN ; ■ ❑ CIVIL PLAN i F-1 ; ❑ ■ ■ CITY OF EDMONDS BUILDING DEPARTMENT 2021 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 (fuel normalization credits) and Table 406.3 (energy credits) to achieve the following minimum number of credits. To claim this credit, the building permit drawings shall specify the option selected and the maximum tested building air leakage, and show the qualifying ventilation system and its control sequence of operation. 1. Small Dwelling Unit: 3 credits Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. 2. Medium Dwelling Unit: 6 credits All dwelling units that are not included in #1 or #3 3. Large Dwelling Unit: 7 credits Dwelling units exceeding 5,000 sf of conditioned floor area 4. Additions less than 500 square feet: 1.5 credits All other additions shall meet 1-3 above Before selecting your credits on this Summary table, review the details in Table 406.3 (Single Family), on page 4. Summary of Table R4061 Heating Credits - select ONE O ons Fuel Normalization Descriptions heating option User Notes 1 Combustion heating minimum NAECAh 0.0 O 2 Heat pump` 1.0 O 3 Electric resistance heat only - furnace or zonal -2.0 0 4 DHP with zonal electric resistance per option 3.4 0.5 0 5 All other heating systems -1.0 O Energy Options p Energy Credit Option Descriptions Credits - select ONE energy option from each cate ory 1.1 1 Efficient Building Envelope 0.5 O 1,2 Efficient Building Envelope 1.0 O 1.3 Efficient Building Envelope 0.5 0 1.4 Efficient Building Envelope 1.0 0 1.5 Efficient Building Envelope 2.0 Q 1.6 Efficient Building Envelope 3.0 O 1.7 Efficient Building Envelope 0 0.5 O 2.1 Air Leakage Control and Efficient Ventilation 0.5 O 2.2 Air Leakage Control and Efficient Ventilation 1.0 O 2.3 Air Leakage Control and Efficient Ventilation 1.5 O 2.4 Air Leakage Control and Efficient Ventilation 2.0 O 3.1' High Efficiency HVAC 1.0 O 3.2 1 High Efficiency HVAC 1.0 O 3.3' High Efficiency HVAC 1.5 O 3.4 High Efficiency HVAC 1.S O 3.5 High Efficiency HVAC 1.5 O 3.61 High Efficiency HVAC 0 2.0 O 4.1 1 High Efficiency HVAC Distribution System 0.5 O 4.2 1 High Efficiency HVAC Distribution System 1.0 Q Prosutptwe Path - Single Family 2018 Washington State Energy Code-R 2 Simple Heating System Size: wasnington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information BUKOWSKI REMODEL+ REPAIR ICITIZEN DESIGN 304 DALEY STREET 110 DRAVUS, SEATTLE, WA 98109 EDMO -D 'A98020 1206.535.7908 Heating System Type: O All Omer systems 0 Beat Pump To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (AT) 46 Edmonds I • AT = Indoor (70 degrees) - Outdoor Design Temp / Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 631 Average Ceiling Height Conditioned Volume Instruction Average Ceiling Height (ft) 7.6 4,783 Glazing and Doors U-Factor X Area = UA Instructions U 028 •J 0.280 120 33.54 Skylights U-Factor X Area = UA Instructions 0.50 0� --- Insulation Attic U-Factor X Area = UA Instruction R_49 0.026 631 16.41 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) U-Factor X Area UA Instructions R-21 Intermediate • 0.056 817 45.76 Floors U-Factor X Area UA Instructions 0.025 631 15.78 R-38 lfl • Below Grade Walls (seeFlgme 1) U-Factor X Area UA Instructions in 0.028 No Below Grade Walls this project. ------ Slab Below Grade (see Figure 1) F-Factor X Length UA Instructions I - � 0.303 0� --- l No Slab Below Grade in this project. Slab on Grade (see Figure r) F-Factor X Length UA Instructions - 0 No Slab on Grade in this project. Location of Ducts Instructions - Duct Leakage Coefficient LN, Ducts 1.00 Sum of UA 111.49 Envelope Heat Load 5,128 Btu / Hour Figure 1. SumofUAxAT Air Leakage Heat Load 2,376 Btu / Hour Volume x 0.6 x AT x 0.018 Above Grade Building Design Heat Load 7,505 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 7,505 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 9,381 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Buildina and duct heat loss x 1.25 for heat puma 2018 Washington State Energy Code - Residential Prescriptive Energy Code Compliance for All Climate Zones in Washington Single Family - New & Additions (effective February 1, 2021) _ Summary of Table R406.2 Cont. Energy Credits - select ONE Energy Credit Option Descriptions (cunt.) energy option from User Notes Options each ca @gory d S.ld Efficient Water Heating 0.5 ❑ 5.2 Efficient Water Heating 0.5 0 5.3 Efficient Water Heating 1.0 O 5.4 1 Efficient Water Heating 1.5 O 5.5 Efficient Water Heating 2.0 O 5.6 Efficient Water Heating 0 2.5 0 6,1e Renewable Electric Energy (3 credits max) 1.0 Q 7.1 Appliance Package 0.5 ❑ Total CrediTtS 1 3.0 Caxulate Total Clear Form a. An alternative heating source sized at a maximum of 0.5 W/sf (equivalent) of heated floor area or 500 W, whichever is bigger, may be installed in the dwelling unit, b. Equipment listed in Table C403.3.2(4) or C403.3.2(5) c, Equipment listed in Table C403.3.2(1) or C403.3.2(2) d. You cannot select more than one option from any category EXCEPT in category 5. Option 5.1 may be combined with options S.2 through S.6. See Table 406.3. e. 1.0 credit for each 1,200 kWh of electrical generation p rovided annually, up to 3 credits max. See the complete Table R406.2 for all requirements and option descriptions. f. Use the single radiobutton in the upper right of the second column to deselect radiobuttons in that group. Please print only pages 1 fhr-wri1­ 7 �"$ thlc: 'uvr)rV-,hP!'t fnr Sl iFlr"ISSIr ih I !-i ! i' r�t r C nff rig-, Presuiptive Path - Single Family 2018 Washington State Energy Code-R Window, Skylight and Door Schedule Project Information BUKOWSKI REMODEL + REPAIR 304 DALEY STREET EDMONDS, WA 98020 Ref. U-factor Exempt Swinging Door (24 sq. ft. max.) A107 0.46 Exempt Glazed Fenestration (15 sq. ft. max.) Vertical Fenestration (Windows and doors) Component DescriDtion Ref. 1-1-factor 4040 SLIDER: AND-N-81-00942-00001 MFR 0.30 4030 SLIDER: AND-N-81-00942-00001 MFR 0.30 5040 SLIDER: AND-N-81-00942-00001 MFR 0.30 3020 FIXED: AND-N-82-03739-00001 MFR 0.28 FRONT DOOR: Exempt per R402.3.4 REAR DOOR: JELD-WEN SmoothPro MFR 0.15 Overhead Glazing (Skylights) Component Contact Information "------- ---- - CITIZEN DESIGN 10 DRAVUS SEATTLE, WA, 98109 206.535.7908 Width Height Qt. Feet Inch Feet Inch 1 13 ° 6 $ Width Height Qt. Feet Inch Feet Inch Sum of Vertical Fenestration Area and UA Vertical Fenestration Area Weighted U = UA/Area UeSCription KeT. U-Tactor NONE PROPOSED Width Height Qt. Feet Inch Feet Inch Sum of Overhead Glazing Area and UA Overhead Glazing Area Weighted U = UA/Area (07101113) Total Sum of Fenestration Area and UA (for heating system sizing calculations) Area UA ', 1 1 • 1 'I 11 111 Area UA •� 1 • 1 ®1 •1 1 1 • 11 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 11 111 119.8 33.15 0.28 Area UA 11 111 11 111 11 111 11 111 11 111 11 111 0.0 0.00 0.00 13 9.842.35 M SCOPE OF ENERGY IMPROVEMENTS ALTER EXISTING RESIDENCE TO CONFORM TO 2018 WSEC RESIDENTIAL M PROVISIONS, PER PLANS AND AS FOLLOWS: • INSULATE ALL OPAQUE THERMAL ENVELOPE ASSEMBLIES IN ACCORDANCE WITH TABLE R402.1.1 AND CREDIT OPTION 1.3. • REPLACE ALL EXTERIOR DOORS AND WINDOWS IN CONDITIONED M SPACE. • INSTALL NEW TAN KLESS GAS WATER HEATER. I T I Z E N • INSTALL NEW DUCTLESS MINI -SPLIT HEAT PUMP. • REPLACE 75% OF LIGHTING (MIN.) WITH HIGH -EFFICACY LUMINAIRES. DESIGN SITE ADDRESS 304 DALEY STREET EDMONDS, WA 98020 ZONING AND LAND AREA ZONING: BD-2 LOT AREA: 2863 SF PARCEL MAP NUMBER 004342-026-001-01 LEGAL DESCRIPTION THE PORTION OF LOTS 1, 2.3, AND 4. BLOCK J, CITY OF EDMONDS, ACCORDING TO THE PLAT THEREOF RECORDED IN VOLUME 2 OF PLATS, PAGE 39, RECORDS OF SNOHOMISH COUNTY, WASHINGTON. BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT THE N.W. CORNER OF SAID LOT 1; THENCE S 88046'18" E ALONG THE NORTH LINE OF SAID LOT FOR A DISTANCE OF 68.63 FT.: THENCE S 30°18'40" W, 64.42 FT.; THENCE N 59°41'20" W, 59.99 FT.; THENCE N 30°20'45" E. 31.06 FT. TO THE POINT OF BEGINNING. JURISDICTION EDMONDS, SNOHOMISH COUNTY, WASHINGTON BUILDING INFORMATION OCCUPANCY: R3 CONSTRUCTION: VB FIRE SUPPRESSION: NONE PROJECT NUMBER BUILDING PERMIT (THIS PERMIT): BLD 2022-0080 PROJECT DIRECTORY OWNER AND DEVELOPER HBRE INVESTMENTS 1951 3RD AVENUE W SEATTLE. WA 98119 DESIGNER AND APPLICANT LEGACY HOME DESIGN P.O. BOX 548 FOX ISLAND, WA 98333 TEL: 253.370.8588 EMAIL: LEGACYHOMEDESIGN@HOTMAIL.COM ENERGY CONSULTANT CITIZEN DESIGN 10 DRAVUS STREET SEATTLE, WA 98109 CONTACT: JACOB YOUNG TEL: 206.853.8055 EMAIL: JYOUNG@COLLABORATIVECO.COM SHEET INDEX ENERGY 0.1 ENERGY CODE ANALYSIS 0.2 PLANS AND ASSEMBLIES BLD2022-0080 a>_ TF * ON 0 ao 2 LU 3; Z O O w H ` w S w F- LU J O W CD 0 t'7 City of EDMONDS Permit Revision March 8, 2023 REVISION Mar 09 2023 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT FOR PLANNING DEPT USE ONLY ENERGY CODE ANALYSIS SCALE: AS NOTED 001