Loading...
DNS RESUB2 BLD2021-0088+FS SHEETS+12.28.2021_5.57.52_PM+2594896-> 1 b V KITCHEN &BISTRO UTILITY SCHEDULE - 1 N V )0V 3 Z/ N 4 0 c q J L 0 .0 VJ Cn 0 E w U CY w a� ry a 0 E w L CLEVENIGER 7WOCITaTE/ m Q FOODSERVICE, BAKERY, 5900 SARATOGA ROAD, SUITE 2A U COMMISSARY AND LAUNDRY PHONE:(563)58251009 M DESIGN/ CONSULTING SEATTLE.CALIFORNIA.ILLINOIS.IOWA .CNEWYO w INFO@CLEVENGERASSOC.COM W WEVENGERA SOC.COM ry a> U ELEC HW HW CW GAS EXH EXH SUP SUP ITEM QTY DESCRIPTION MANUFACTURER MODEL FURNISHED BY INSTALLED BY VOLTS PHASE AMPS HP TYPE AFF ELECTRICAL COMMENTS SIZE AFF FLOW SIZE AFF WASTE TYPE DIA AFF MBTU DIA AFF PLUMBING COMMENTS WIDTH DEPTH CFM S.P. WIDTH DEPTH CFM S.P. VENTILATION COMMENTS ITEM 1 1 WALK-IN FREEZER/ COOLER AMERICAN PANEL AMERICAN PANEL KEC KEC 120 1 8.0 DIR STUB DOWN, SEE DETAIL "5" SHEET FS-2 FOR WIRING 1 ASSEMBLY DIAGRAM 2 1 EVAPORATOR COIL(COOLER) AMERICAN PANEL ADT-120AEK KEC KEC 120 1 2.0 DIR STUB DOWN, SEE DETAIL "5" SHEET FS-2 FOR WIRING FS 1" 2 DIAGRAM 3 1 COMPRESSOR REMOTE, AIR-COOLED AMERICAN PANEL D8AJ-0200 KEC KEC 208 3 8.8 DIR VERIFY LOCATION OF ROUGH -IN 3 4 1 WALK-IN FREEZER/ COOLER AMERICAN PANEL AMERICAN PANEL KEC KEC 120 1 8.0 4 ASSEMBLY 5 1 EVAPORATOR COIL(FREEZER) AMERICAN PANEL ADT-120AEK KEC KEC 208 1 1.4 DIR STUB DOWN, SEE DETAIL "5" SHEET FS-2 FOR WIRING FS 1" 5 DIAGRAM 6 1 COMPRESSOR REMOTE, AIR-COOLED AMERICAN PANEL DJAC-0200 KEC KEC 208 3 13.7 DIR VERIFY LOCATION OF ROUGH -IN 6 7 8 WIRE SHELVING UNIT METRO 2136NK3 KEC KEC 7 8 2 WIRE SHELVING UNIT METRO 2136NK3 KEC KEC 8 8.1 2 WIRE SHELVING UNIT METRO 2136NK3 KEC KEC 8.1 8.2 1 WIRE SHELVING UNIT METRO 2124NK3 KEC KEC 8.2 9 1 SPARE NUMBER 9 10 1 SPARE NUMBER 10 11 1 SPARE NUMBER 11 12 2 FAUCET W/WRIST HANDLES EAGLE 313293 KEC KEC 12" 60 12" (2 @ 3/4" H. & C.W.) 12 13 1 THREE COMPARTMENT SINK EAGLE GROUP 414-18-3-18 KEC KEC DIR 2" 18" (3 @ 2" WASTE) MANIFOLD DRAIN LINES, PLUMB 13 B DRAINS PER LOCAL CODES 14 1 SHELVES WITH REMOVABLE HOOKS EAGLE GROUP WSP1596 KEC KEC 14 15 3 HAND SINK WITH SOAP AND TOWEL EAGLE GROUP HSA-10-FDP KEC KEC 1/2" 18" 5 1/2" 18" 15 DISPENSERS 16 1 CAN RACK NEW AGE 97294 KEC KEC 16 INDUSTRIAL 17 5 WIRE SHELVING UNIT METRO 2448NK3 KEC KEC 17 18 2 HIGH DENSITY SHELVING -STATIONARY METRO TTE18K3 KEC KEC 18 19 6 HIGH DENSITY SHELVING -MOBILE METRO TTM18K3 KEC KEC 19 20 1 SPARE NUMBER 20 21 2 HIGH DENSITY SHELVING SYSTEM - METRO TTS16.5K3 KEC KEC 21 TRACK 22 1 SPARE NUMBER 22 23 1 SPARE NUMBER 23 24 1 UTILITY CART CAMBRO BC340KD110 KEC KEC 24 25 1 WALL MOUNTED SHELF EAGLE GROUP WSP1248 KEC KEC 25 26 1 DISHTABLE, STRAIGHT EAGLE GROUP CDTL-60-14/3 KEC KEC 26 27 1 DISHRACK DOLLY METRO DH2O20N KEC KEC 27 28 1 DISHRACK DOLLY METRO PCD12 KEC KEC 28 29 1 DOOR TYPE DISHMACHINE -TALL JACKSON TEMPSTAR HH-E LEASE LEASE 208 1 81.4 2 72" 3/4" 72" 1.2 1/2" 18" COLD WATER TEMPERING KIT 29 30 1 CONDENSATE HOOD CUSTOM CONDENSATE HOOD KEC KEC 7" 7" 600 0.50 SEE FSV-5 SHEETS FOR ADDITIONAL INFORMATION AND 30 DETAILS 31 1 TRASH CAN WITH DOLLY RUBBERMAID FG263200GRAY KEC KEC 31 32 1 SOILED DISHTABLE EAGLE GROUP SDTL-120-14/3 -MODIFIED KEC KEC A 32 32.1 1 WASTE DRAIN, TWIST HANDLE T&S BRASS B-3942 KEC KEC FS -GREASE 2" 32.1 33 1 PRE -RINSE FAUCET T&S BRASS B-0113-B KEC KEC 1/2" 12" 35 1/2" 12" 33 34 1 SLANTED RACK SHELF CUSTOM RACK SHELF KEC KEC 34 35 1 FILTRATION SYSTEM (STEAMER) PENTAIR EV9797-22 KEC KEC 1/2" 72" RUN C.W TO ITEM 68, CONVECTION STEAMER AND 35 ITEM 95, ICE CUBER 36 1 HOSE REEL, ENCLOSED, STAINLESS T&S BRASS. B-7142-0O2 KEC KEC 1/2" 12" 30 1/2" 12" 36 STEEL 37 1 WATER CONTROL CABINET T&S BRASS B-2339-LR KEC KEC 37 38 1 SPARE NUMBER 38 39 1 SPARE NUMBER 39 40 1 FOOD PROCESSOR ROBO COUPE R401 KEC KEC 120 1 12.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, 40 VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) 41 1 SPARE NUMBER 41 42 1 FOOD SLICER UNIVEX 6612S NSF8 KEC KEC 120 1 4.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, 42 VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) 43 1 LOW VOLTAGE COOK &HOLD OVEN FWE LCH-6-LV-G2 KEC KEC 120 1 17.2 43 44 1 CABINET, HOLDING METRO C519-CFC-4 KEC KEC 120 1 16.0 REC STUB DOWN, PROVIDE DROP -CORD WITH TWIST -LOCK, 44 VERIFY ALL REQUIREMENTS (BY ELECTRICAL DIVISION) 45 1 SPARE NUMBER 45 46 1 SPARE NUMBER 46 47 1 WORKTABLE W/SINKS EAGLE GROUP SMPT30108 KEC KEC FS -GREASE (2 @ 1 1/2" WASTE) 47 48 1 FAUCET T&S BRASS B-0231-230KIT KEC KEC 1/2" 20 1/2" STUB UP H. & C.W. 48 49 1 SPARE NUMBER 49 50 1 MOP BUCKET AND RINGER RUBBERMAID FG768000YEL KEC KEC 50 51 1 MOP SINK IMC TEDDY FS-R KEC KEC DIR -GREASE 2" 1" TRAP BELOW FLOOR 51 52 1 SERVICE FAUCET T&S BRASS B-0655-BSTP KEC KEC 1/2" 36" 15 1/2" 36" 52 53 1 CB STARTER 4V 21X36X84 CAMBRO CBU213684V4580 KEC KEC 53 54 1 WALL MOUNTED FAUCET T&S BRASS B-0325 KEC KEC 1/2" 12" 10 1/2" 12" 54 55 3 INGREDIENT BIN CAMBRO IBS20-148 KEC KEC 55 56 1 WORKTABLE W/SINK EAGLE GROUP T3084SE-BS KEC KEC FS -GREASE 1 1/2" 56 57 1 SPARE NUMBER q 57 58 1 PLANETARY MIXERS UNIVEX SRM20 KEC KEC 120 1 10.6 REC 48" 58 M 59 60 1 UNDERCOUNT R R F IGERATOR TRUE UC-27-HC-LP KEC KEC 120 1 2.0 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 CONDENSATE EVAPORATOR 60 1 1 R V S EA L UP DO 28 - K E 61 62 1 SPARE NUMBER 62 63 1 ICED TEA BREWER BUNN TU5Q - 41400 BY VENDOR BY VENDOR 120 1 14.0 REC 48" VERIFY REQUIREMENTS WITH VENDOR SUPPLIED 1/2" RUN C.W FROM ITEM 93, WATER FILTER. VERIFY 63 IP R T I R SUPPLIED EQUIPMENT 64 1 UNDERCOUNTER FREEZER TRUE TUC-27F-HC-LP KEC KEC 120 1 5.0 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 CONDENSATE EVAPORATOR 64 65 1 POT &PAN SHELVING EAGLE GROUP S5-86-2430VG KEC KEC 65 A M 3 N 6600 66.1 1 FILTRATION SYSTEM VULCAN MF-1 KEC KEC 120 1 5.0 REC 18" 66.1 68 1 CONVECTION STEAMER CLEVELAND 21CGA5 KEC KEC 120 1 4.0 REC 18" 3/4" 36" FS -GREASE 1 1/4" A 70 1/2" 18" (2 @ 3/4" C.W) RUN (1) C.W. FROM ITEM 35, WATER 68 FILTER. PROVIDE QUICK DISCONNECT 69 1 REFRIGERATED CHEF BASE RANDELL 20048SC KEC KEC 120 1 6.0 REC 18" CONDENSATE EVAPORATOR 69 70 1 CHARBROILER GARLAND GTBG24-NR24 KEC KEC 72 3/4" 18" PROVIDE QUICK DISCONNECT 70 71 1 RANGE 6-BURNER W/24" GRIDDLE GARLAND G60-6G24RR KEC KEC 120 1 3.4 REC 18" 307 1" 18" PROVIDE QUICK DISCONNECT 71 7 1 /2" 60" 72 73 1 DUMP STATION HATCO GRFHS-16 KEC KEC 120 1 9.1 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 73 4 T E WALL PA EL WA K E 74 75 1 DOUBLE DECK CONVECTION OVEN VULCAN VC66GD KEC KEC 1 REC (2 @ 120V AT 8.0 AMPS EA.) (1) 18" A.F.F., (1) 36" A.F.F. 100 3/4" 18" PROVIDE QUICK DISCONNECT 75 76 1 TYPE 1 EXHAUST HOOD CADDY EXHAUST HOOD KEC KEC 1 DIR (2 @ 120V AT 15.0 AMPS EA.) STUB DOWN; LIGHT AND FAN 34" 10" 4200 1.40 (2 @ 12" X 24" SUPPLY AT 1,680 CFM EA., 0.20 S.P.) SEE 76 SWITCH BY ELEC. DIV; AUTOSTART/ STOP FAN INTERLOCK. FSV-1 SHEETS FOR ADDITIONAL INFORMATION AND SEE FSV-1 SHEET FOR ADDITIONAL INFORMATION AND DETAILS DETAILS 77 1 FIRE SUPPRESSION SYSTEM ANSUL R-102 KEC KEC 120 1 2.0 DIR STUB DOWN, CONDUIT RUN ABOVE CEILING 77 78 1 HEATED PLATE DISPENSER LAKESIDE 6212 KEC KEC 120 1 7.5 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 78 79 1 MAGNETIC KNIFE HOLDER MERCER M30750 BY OWNER BY OWNER 79 80 1 CHEFS COUNTER CUSTOM CHEFS TABLE KEC KEC 208 3 100.0 DIR STUB UP, CONNECT TO FIXTURE MOUNTED JBOX (BY 80 ELECTRICAL DIVISION) 80.1 1 DOUBLE OVERSHELF CUSTOM OVER SHELF KEC KEC 80.1 81 2 DROP -IN SOUP WELL APW Wyott SM-50-11D UL KEC KEC 208 1 2.4 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 FS -GREASE 1/2" 81 82 2 FILL FAUCET T&S BRASS B-0208 KEC KEC 1/2" 10 1/2" A STUB UP C.W. 82 83 1 MICROWAVE OVEN ACP, INC MDC12A2 KEC KEC 120 1 16.8 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 83 84 1 CONVEYOR TOASTER HATCO TQ-800HBA KEC KEC 208 1 15.8 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 84 85 2 OVERHEAD FOOD WARMER HATCO GRAHL-66 KEC KEC 120/208 1 10.0 JBOX PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 85 86 1 HOT FOOD TABLE RANDELL 3614 KEC KEC 208 1 16.6 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 FS -GREASE (4 @ 1/2' WASTE) MANIFOLD DRAIN LINES 86 87 1 REFRIGERATOR, SANDWICH/SALAD RANDELL 9305-7 KEC KEC 120 1 5.5 REC PRE -WIRED TO CIRCUIT BREAKER PANEL IN ITEM #80 A CONDENSATE EVAPORATOR 87 PREP 88 1 SPARE NUMBER 88 89 1 SODA &ICE BEVERAGE DISPENSER LANCER 85-20406-0-0-31 E BY VENDOR BY VENDOR 120 1 3.0 48" 1/2" 48" RUN C.W FROM ITEM 93, WATER FILTER. VERIFY 89 REQUIREMENTS WITH VENDOR SUPPLIED EQUIPMENT 90 1 BAG -IN -BOX SYSTEM EAGLE 3B2136C BY VENDOR BY VENDOR 120 1 15.0 REC 72" VERIFY REQUIREMENTS WITH VENDOR SUPPLIED 1/2" 72" A VERIFY REQUIREMENTS WITH VENDOR SUPPLIED 90 EQUIPMENT EQUIPMENT 91 1 BEVERAGE COUNTER EAGLE T30108SE-BS KEC KEC 1/2" 12" 10 1/2" 12" FS -GREASE 91 92 1 HIGH VOLUME COFFEE DISPENSER NEXT-GEN NG-300 BY VENDOR BY VENDOR 208 1 30.0 48" NEMA L-14-30 1/2" 110 - 140 DEGREE WATER CONNECTION 92 93 1 FILTER SYSTEM PENTAIR EV9437-11 KEC KEC 3/4" 72" RUN C.W TO ITEM 63, ICED TEA BREWER AND ITEM, 89 93 SODA DISPENSER &ITEM 96 JUICE DISPENSER 94 1 REFRIGERATOR TRAULSEN G11010 KEC KEC 120 1 7.4 REC 84" CONDENSATE EVAPORATOR VENTILATION REQUIRES TO EXHAUST 2.2 MBTU'S PER 94 HOUR (BY MECHANICAL DIVISION) 95 1 ICE CUBER MANITOWOC IDT-0502A KEC KEC 208 1 11.5 JBOX 72" 1/2" FS 1/2" RUN C.W FROM ITEM 35, WATER FILTER VENTILATION REQUIRED TO EXHAUST 5.0 MBTU'S PER 95 HOUR (BY MECHANICAL DIVISION) 95.1 1 ICE BIN MANITOWOC D-570 KEC KEC FS 3/4" 95.1 96 1 JUICE DISPENSER CORNELIUS 721404101JU1 BY VENDOR BY VENDOR 120 1 9.0 48" 1/2" 48" RUN C.W FROM ITEM 93, WATER FILTER. VERIFY 96 0CY REQUIREMENTS WITH VENDOR SUPPLIED EQUIPMENT 97 1 ICE CREAM CABINET MASTER-BILT DC-4D 120 1 2.7 REC 18" CONDENSATE EVAPORATOR 97 7. I A06 - 0 K E FS -GREASE 1/2" 97.1 FOR REFERENCE ONLY FOR REFERENCE ONLY 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 ©ANKROM MOISAN ARCHITECTS, INC. O N O O') (n Z O Z z O = Q W c6 O Z O N i co J > J _� � O N 0 ti Z m p W � Z C:) U) � Q N U a REVISION DATE REASON FOR ISSUE 4 08/18/2021 OWNER CHANGES A 08/18/2021 CITY COMMENT CHANGES B 10/29/2021 CITY COMMENTS #02 RESUB Dec 28 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0088 EQUIPMENT SCHEDULE PERMIT/GMP SET DATE PROJECT NUMBER 05.21.21 180950 L D 0 t V D 7 8 9 10 12 13 PLUMBING NOTES 1. PLUMBING PLANS SHOW ROUGH -IN POINTS AND SCHEDULED CONNECTIONS. KITCHEN EQUIPMENT CONTRACTOR WILL PROVIDE DIMENSIONED ROUGH -IN DRAWING FOR CONSTRUCTION. 2. WATER PRESSURE IN FOOD AND BEVERAGE AREAS SHOULD BE 50 PSIG (345 KPa) MAXIMUM. WATER PRESSURE AT DISHMACHINES, BOOSTER HEATERS, GLASS AND UTENSIL WASHERS TO BE 25 PSIG (172 KPa). 3. PLUMBING DIVISION SHALL FURNISH AND INSTALL ALL NECESSARY VALVES, TRAPS, TAIL PIECES, LINE STRAINERS, WATER PRESSURE REDUCING VALVES (SINGLE AND/OR DUAL CHECK VALVES) AND VACUUM BREAKERS AND CONNECT ALL WATER, FUEL GAS, STEAM AND WASTE LINES TO FOOD SERVICE AND BEVERAGE EQUIPMENT. 4. PLUMBING DIVISION SHALL INSTALL AND CONNECT ALL FAUCETS FURNISHED BY KEC. 5. PLUMBING DIVISION SHALL FURNISH AND INSTALL ALL INDIRECT SINK AND VENTILATOR WASTE LINES TO FLOOR SINKS. 6. PLUMBING DIVISION TO PROVIDE ADEQUATE CLEAN -OUT FOR DRAIN LINES. 7. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH AND INSTALL FIRE PROTECTION SYSTEM (INCLUDING FURNISHING SOLENOID SHUTOFF VERIFY LOCATION WITH KEC. 8. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH FINISH FLOOR OR PER LOCAL CODE WITH GRATE COVER AS INDICATED. 9. FLOOR DRAINS INDICATED ARE FOR FOOD AND BEVERAGE AREAS ONLY. ADDITIONAL GENERAL PURPOSE AREA DRAINS SHALL BE LOCATED BY THE PLUMBING ENGINEER/ ARCHITECT. 10. KITCHEN EQUIPMENT CONTRACTOR SHALL FURNISH AND INSTALL FIRE PROTECTION SYSTEM (INCLUDING FURNISHING SOLENOID SHUTOFF VALVES). PLUMBING DIVISION SHALL INSTALL SHUTOFF VALVE. VERIFY LOCATION WITH KEC. 11. FLOOR SINKS SHALL BE INSTALLED FLUSH WITH FINISH FLOOR OR PER LOCAL CODE WITH GRATE COVER AS INDICATED. 12. FLOOR DRAINS INDICATED ARE FOR FOOD AND BEVERAGE AREAS ONLY. ADDITIONAL GENERAL PURPOSE AREA DRAINS SHALL BE LOCATED BY THE PLUMBING ENGINEER/ ARCHITECT. 13. EYE/FACE WASH STATION SHALL MEET DOSH EMERGENCY WASHING REQUIREMENTS, ANZI ZZ358.1 EMERGENCY EYE WASH AND SHOWER REQUIREMENTS. KITCHEN EQUIPMENT CONTRACTOR SHALL VERIFY UNIT MEETS WITH LOCAL JURISDICTION/CODES AND PROVIDE TRAINING. PLUMBING DIVISION SHALL PROVIDE THERMOSTATIC MIXING VALVE AND BACK FLOW PREVENTION TO MEET ALL REQUIREMENTS. PLUMBING SYMBOLS HW-HOT WATER, OR CW-COLD WATER o- WASTE, DIRECT -CONNECTED UNLESS NOTED "OPEN HUB" o--- INDIRECT WASTE O FLOOR DRAIN FLOOR DRAIN WITH FUNNEL C 0 HUB DRAIN DRAIN IN FLOOR RECESS, CONNECT TO GENERAL CONTR. DRAIN PAN ® FLOOR SINK WITH HALF GRATE UNLESS NOTED OTHERWISE FLOOR SINK WITH FUNNEL GRATE D ® GAS GAS PRESSURE REGULATORY/BY KEC 0 STEAM SUPPLY 0 CONDENSATE RETURN CE) — ----(�G) NOTE KITCHEN EQUIPMENT CONTRACTOR TO VERIFY AND COORDINATE PROPER LOCATION AND SIZE OF GENERAL CONTRACTOR FURNISHED STRUCTURAL PENETRATIONS AND PLUMBING DIVISION FURNISHED SLEEVES THRU FLOOR. NOTE KITCHEN EQUIPMENT CONTRACTOR TO VERIFY AND COORDINATE PROPER LOCATION AND SIZE OF GENERAL CONTRACTOR FURNISHED STRUCTURAL PENETRATIONS AND PLUMBING DIVISION FURNISHED SLEEVES THRU FLOOR. REFRIGERATION CONT'R TO SEAL PENETRATION INSULATED SUCTION LINE & LIQUID LINE AIR OW COPPER UNION TO BE SUPPLIED AND INSTALLED BY KEC ALL DRAIN LINES REQUIRE A MINIMUM OF 1/2" FALL PER FT. ELECT. HEATER SPIRALED & TAPED ON FREEZER DRAIN BY REFRIGERATION CONTRACTOR COPPER DRAIN LINE INSULATED WALL NOTES: 1. RUN EACH DRAIN SEPARATELY 2. MINIMUM 15" GAP FROM WALL TO COI COIL 1'-311 381 mm LL _ Q E E N M O N (3) CONDENSATE DRAIN (TYPICAL) TRAP PROJECT CLEVENGE-R Ta//OCITaTE/ A B FOODSERVICE, BAKERY, 5900 SARATOGA ROAD SUITE 2A DUBUQUE, IOWA 52002 COMMISSARY AND LAUNDRY PHONE: (563) 582-5109 DESIGN/ CONSULTING SEATTLE.CALIFORNIA.ILLINOIS.IOWA NEW YORK.PHILIPPINES D INFO@CLEVENGERASSOC.COM WWWCLEVENGERASSOC.COM C KEY o I AA FOR REFERENCE ONLY 38 NORTHWEST DAVIS, SUITE 300 PORTLAND, OR 97209 503.245.7100 1505 5TH AVE, SUITE 300 SEATTLE, WA 98101 206.576.1600 1014 HOWARD STREET SAN FRANCISCO, CA 94103 415.252.7063 © ANKROM MOISAN ARCHITECTS, INC. CD N 0 00 rn Cl) z 0 Z z 0= Q W (n LL z 0 0 2 LLI CD 0 a> > J > J 0 -0 p N _ 0 I` z m F_ C:)W Z N U a� U Ir QN LU REVISION DATE REASON FOR ISSUE B 10/29/2021 CITY COMMENTS #02 RESUB Dec 28 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0088 PLUMBING ROUGH -INS PLAN PERMIT/GMP SET DATE PROJECT NUMBER 05.21.21 180950