Loading...
REVIEWED BLD2021-0088+Energy_Code_Sheet_or_Envelope_Summary+5.21.2021_8.15.45_PM+2211581COMcheck Software Version COMcheckWeb Envelope Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area Construction Site: 21200 72nd ave W Edmonds, WA 98026 2015 IECC Edmonds Senior Living Edmonds, Washington 4c New Construction 29% Owner/Agent: Matt Booma CA Senior Living Holdings, LLC 130 East Randolph St Suite 2100 Chicago, IL 60601 3122391896 mbooma@ca-ventures.com Additional Efficiency Package(s) Credits: 1.0 Required 1.0 Proposed High Performance HVAC, 1.0 credit Building Area Floor Area 1-Multifamily : Residential 164000 Envelope Assemblies Assembly Main Roof: Insulation Entirely Above Deck, [Bldg. Use 1 - Multifamily] Conc Roof under MC Courtyard- r-38 insulation at underside: Other Roof, [Bldg. Use 1 - Multifamily] (b) 6th Floor Ext Deck: Attic Roof with Wood joists, [Bldg. Use 1 - Multifamily] Floor 1: Concrete Floor (over unconditioned space), [Bldg. Use 1 - Multifamily] Floor 2 over Garage: Concrete Floor (over unconditioned space), [Bldg. Use 1 - Multifamily] NORTH Exterior Wall 1: Steel -Framed, 24" o.c., [Bldg. Use 1 - Multifamily] Window 1: Metal Frame with Thermal Break: Fixed, Perf. Specs.: Product ID Storefront, SHGC 0.27, [Bldg. Use 1 - Multifamily] (c) Door 1: Glass (> 50% glazing):Metal Frame, Entrance Door, Perf. Specs.: Product ID Storefront, SHGC 0.16, [Bldg. Use 1 - Multifamily] (c) Exterior Wall 2: Solid Concrete:12" Thickness, Normal Density, Furring: None, [Bldg. Use 1 - Multifamily] Door 2: Insulated Metal, Swinging, [Bldg. Use 1 - Multifamily] Exterior Wall 3: Wood -Framed, 16" o.c., [Bldg. Use 1 - Multifamily] RESUB May 24 2021 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2021-0088 Designer/Contractor: Mark Miller Ankrom Moisan Architects 38 NW Davis St Portland, OR 97209 5032457100 markcm@ankrommoisan.com Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(a) Perimeter 19167 --- 38.0 0.026 0.032 1209 --- --- 0.026 0.021 1700 0.0 49.0 0.020 0.021 9706 --- 30.0 0.030 0.064 25734 --- 30.0 0.030 0.064 1832 13.0 10.0 0.052 0.064 777 --- --- 0.310 0.380 66 --- --- 0.250 0.770 123 --- 10.0 0.083 0.080 25 --- --- 0.170 0.370 9988 21.0 0.0 0.062 0.064 Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 1 of 9 Assembly Gross Area Cavity Cont. Proposed Budget U- or R-Value R-Value U-Factor Factor(a) Perimeter Window 2: Vinyl Frame: Operable, Perf. Specs.: Product ID 3432 --- --- 0.280 0.450 Milgard Tuscany Series, SHGC 0.29, [Bldg. Use 1 - Multifamily] (c) EAST Exterior Wall 4: Concrete Block:8", Solid Grouted, Medium 100 --- 0.0 0.580 0.080 Density, Furring: None, [Bldg. Use 1 - Multifamily] Exterior Wall 5: Wood -Framed, 16" o.c., [Bldg. Use 1 - 6960 21.0 0.0 0.062 0.064 Multifamily] Window 4: Vinyl Frame: Operable, Perf. Specs.: Product ID 2240 --- --- 0.280 0.450 Milgard Tuscany Series, SHGC 0.29, [Bldg. Use 1 - Multifamily] (c) Exterior Wall 6: Solid Concrete:12" Thickness, Normal Density, 1307 --- 10.0 0.083 0.080 Furring: None, [Bldg. Use 1 - Multifamily] Door 3: Insulated Metal, Swinging, [Bldg. Use 1 - Multifamily] 80 --- --- 0.170 0.370 Door 4: Uninsulated Single -Layer Metal, Non -Swinging, [Bldg. 100 --- --- 0.650 0.179 Use 1 - Multifamily] Basement Wall 1: Solid Concrete:12" Thickness, Normal 459 --- 9.5 0.090 0.119 Density, Furring: None, Wall Ht 11.8, Depth B.G. 5.5, [Bldg. Use 1 - Multifamily] Exterior Wall 7: Steel -Framed, 24" o.c., [Bldg. Use 1 - 509 13.0 10.0 0.052 0.064 Multifamily] Window 6: Metal Frame with Thermal Break: Fixed, Perf. 328 --- --- 0.310 0.380 Specs.: Product ID Storefront, SHGC 0.27, [Bldg. Use 1 - Multifamily] (c) SOUTH Exterior Wall 8: Concrete Block:8", Solid Grouted, Medium 1356 --- 0.0 0.580 0.080 Density, Furring: None, [Bldg. Use 1 - Multifamily] Exterior Wall 9: Wood -Framed, 16" o.c., [Bldg. Use 1 - 10144 21.0 0.0 0.062 0.064 Multifamily] Window 7: Vinyl Frame: Operable, Perf. Specs.: Product ID 3286 --- --- 0.280 0.450 Milgard Tuscany Series, SHGC 0.29, [Bldg. Use 1 - Multifamily] (c) Exterior Wall 10: Solid Concrete:12" Thickness, Light Density, 1194 --- 0.0 0.270 0.080 Furring: None, [Bldg. Use 1 - Multifamily] Basement Wall 2: Solid Concrete:10" Thickness, Normal 955 --- 9.5 0.091 0.119 Density, Furring: None, Wall Ht 12.8, Depth B.G. 6.0, [Bldg. Use 1 - Multifamily] WEST Exterior Wall 11: Wood -Framed, 16" o.c., [Bldg. Use 1 - 7174 21.0 0.0 0.062 0.064 Multifamily] Window 8: Vinyl Frame: Operable, Perf. Specs.: Product ID 1965 --- --- 0.280 0.450 Milgard Tuscany Series, SHGC 0.29, [Bldg. Use 1 - Multifamily] (c) Exterior Wall 12: Solid Concrete:12" Thickness, Normal 1182 --- 10.0 0.083 0.080 Density, Furring: None, [Bldg. Use 1 - Multifamily] Door 5: Insulated Metal, Swinging, [Bldg. Use 1 - Multifamily] 55 --- --- 0.170 0.370 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. (b) 'Other' components require supporting documentation for proposed U-factors. (c) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version COMcheckWeb and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 2 of 9 Mark Miller - Principal 05.21.2021 Name - Project Title: Edmonds Senior Living Data filename: mature Date Report date: 05/19/21 Page 3 of 9 COMcheck Software Version COMcheckWeb Inspection Checklist Energy Code: 2015 IECC Requirements: 41.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all QComplies Requirement will be met. [PR1]1 information with which compliance QDoes Not can be determined for the building ❑Not Observable Location on plans/spec: A0.01, Project Manual envelope and document where QNot Applicable exceptions to the standard are claimed. C402.4.1 The vertical fenestration area <= 30 QComplies Requirement will be met. [PR10]1 percent of the gross above -grade wall QDoes Not area. QNot Observable Location on plans/spec: Architectural elevations FTNot Applicable C402.4.1 The skylight area <= 3 percent of the Complies Requirement will be met. [PR11]1 gross roof area. QDoes Not QNot Observable Location on plans/spec: No skylights in project. QNot Applicable C402.4.2 In enclosed spaces > 2,500 ft2 QComplies Exception: Requirement does not apply. [PR14]1 directly under a roof with ceiling QDoes Not heights >15 ft. and used as an office, QNot Observable Location on plans/spec: No skylights in project. lobby, atrium, concourse, corridor, QNot Applicable storage, gymnasium/exercise center, convention center, automotive service, manufacturing, non - refrigerated warehouse, retail store, distribution/sorting area, transportation, or workshop, the following requirements apply: (a) the daylight zone under skylights is >= half the floor area; (b) the skylight area to daylight zone is >= 3 percent with a skylight VT >= 0.40; or a minimum skylight effective aperture >= 1 percent. C405.6 Group R-2 dwelling units have QComplies Requirement will be met. [PR16]1 separate electrical meters. QDoes Not HNot Observable Not Applicable C406 Plans, specifications, and/or QComplies Requirement will be met. [PR9]1 calculations provide all information QDoes Not with which compliance can be QNot Observable determined for the additional energy QNot Applicable efficiency package options. Additional Comments/Assumptions: 11 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 4 of 9 Section # Footing / Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 Below -grade wall insulation installed QComplies Requirement will be met. [F02]2 per manufacturer's instructions. QDoes Not ❑Not Observable Location on plans/spec: A0.11, Project Manual QNot Applicable C303.2.1 Exterior insulation protected against QComplies Requirement will be met. [F06]1 damage, sunlight, moisture, wind, QDoes Not landscaping and equipment ❑Not Observable maintenance activities. QNot Applicable C402.2.6 Radiant heating systems panels QComplies :Exception: Requirement does not apply. [FO12] insulated to >=R-3.5 on face opposite QDoes Not space being heated. I :See the Envelope Assemblies table for values. '❑Not Observable QNot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 5 of 9 Section # Framing / Rough -In Inspection Complies? Comments/Assumptions & Req.ID C303.1.3 Fenestration products rated in QComplies Requirement will be met. [FR12]2 accordance with NFRC. QDoes Not ❑Not Observable Location on plans/spec: Project Manual QNot Applicable , C303.1.3 Fenestration products are certified as QComplies Requirement will be met. [FR13]1 to performance labels or certificates QDoes Not provided. ❑Not Observable Location on plans/spec: Project Manual QNot Applicable C402.4.3 'Vertical fenestration SHGC value. QComplies ;See the Envelope Assemblies table for values. [FR10]1 QDoes Not ❑Not Observable QNot Applicable C402.4.3, Vertical fenestration U-Factor. QComplies See the Envelope Assemblies table for values. C402.4.3. QDoes Not 4 [FR8]1 ❑ Not Observable QNot Applicable C402.4. U-factor of opaque doors associated QComplies ;See the Envelope Assemblies table for values. [FR14]2 with the building thermal envelope QDoes Not meets requirements. dNot Observable QNot Applicable C402.5.7 Vestibules are installed on all building QComplies Requirement will be met. [FR17]3 entrances. Doors have self -closing QDoes Not devices. ❑Not Observable Location on plans/spec: A2.01 QNot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 6 of 9 Section # & Req.ID Mechanical Rough -In Inspection Complies? Comments/Assumptions C402.5.5, Stair and elevator shaft vents have QComplies Requirement will be met. C403.2.4. motorized dampers that automatically QDoes Not 3 close. '❑Not Observable Location on plans/spec: Please see Mechanical drawings [ME3]3 QNot Applicable C402.5.5, Outdoor air and exhaust systems have QComplies Requirement will be met. C403.2.4. motorized dampers that automatically QDoes Not 3 shut when not in use and meet ❑Not Observable Location on plans/spec: Please see Mechanical drawings [ME58]3 maximum leakage rates. Check QNot Applicable gravity dampers where allowed. Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 7 of 9 Section # & Req.ID Insulation Inspection Complies? Comments/Assumptions C303.1 Roof insulation installed per QComplies Requirement will be met. [IN3]1 manufacturer's instructions. Blown or QDoes Not poured loose -fill insulation is installed ❑Not Observable Location on plans/spec: A0.31, Project Manual only where the roof slope is <=3 in QNot Applicable 12. C303.1 Building envelope insulation is labeled QComplies :Requirement will be met. [IN10]2 with R-value or insulation certificate QDoes Not providing R-value and other relevant ❑Not Observable I MJdata. QNot Applicable C303.2 Above -grade wall insulation installed JETComplies Requirement will be met. [IN7]1 per manufacturer's instructions. QDoes Not C303.2, Floor insulation installed per C402.2.4 manufacturer's instructions. Cavity or [IN9]2 structural slab insulation installed in permanent contact with underside of decking or structural slabs. C303.2.1 Exterior insulation is protected from [IN14]2 damage with a protective material. Verification for exposed foundation insulation may need to occur during Foundation Inspection. C402.2.1 Insulation intended to meet the roof [IN17]3 insulation requirements cannot be installed on top of a suspended ceiling. Mark this requirement compliant if insulation is installed accordingly. C104 Installed above -grade wall insulation [IN6]1 type and R-value consistent with insulation specifications reported in plans and COMcheck reports. of Observable Location on plans/spec: A0.11, Project Manual of Applicable Complies Requirement will be met. Does Not Not Observable Location on plans/spec: A0.31, Project Manual Not Applicable Complies ;Requirement will be met. Does Not Not Observable: Location on plans/spec: A0.11, Project Manual Not Applicable Complies Requirement will be met. Does Not Not Observable Location on plans/spec: A0.31, Project Manual Not Applicable Complies See the Envelope Assemblies table for values. Does Not Not Observable Not Applicable C104 Installed floor insulation type and R- QComplies ;See the Envelope Assemblies table for values. [IN8]2 value consistent with insulation QDoes Not specifications reported in plans and COMcheck reports. ❑Not Observable QNot Applicable C402.2.6 [IN18]3 0 I Radiant panels and associated components, designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. C104 Installed roof insulation type and R- [IN2]1 value consistent with insulation specifications reported in plans and COMcheck reports. For some ceiling systems, verification may need to occur during Framing Inspection. C402.5.1. All sources of air leakage in the 1 building thermal envelope are sealed, [IN1]1 caulked, gasketed, weather stripped or wrapped with moisture vapor - permeable wrapping material to minimize air leakage. Additional Comments/Assumptions: Complies Exception: Requirement does not apply. Does Not Not Observable Location on plans/spec: No radiant panels on project Not Applicable LComplies See the Envelope Assemblies table for values. QDoes Not ❑Not Observable QNot Applicable QComplies Requirement will be met. QDoes Not ❑Not Observable Location on plans/spec: A7 drawing series, Project Manual QNot Applicable 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 8 of 9 Section # Final Inspection & Req.ID C402.5 Building envelope contains a [F155]1 continuous air barrier that has been tested and deemed to limit air leakage <= 0.40 cfm/ft2. Complies? Comments/Assumptions Complies ' Requirement will be met. Does Not Not Observable, Location on plans/spec: A7 drawing series, Project Manual Not Applicable C402.5.6 Weatherseals installed on all loading QComplies Requirement will be met. [FI37]1 dock cargo doors. QDoes Not ❑Not Observable' Location on plans/spec: A7.12, Project Manual QNot Applicable Additional Comments/Assumptions: 111 High Impact (Tier 1) 12 1 Medium Impact (Tier 2) 13 1 Low Impact (Tier 3) Project Title: Edmonds Senior Living Report date: 05/19/21 Data filename: Page 9 of 9