Loading...
RFI 326 - SKETCH (2)0 0 u C u u u GENERAL NOTES - ENLARGED PLANS KEY NOTES - UNIT PLANS GENERAL NOTES - RCP RCP LEGEND 1. REFER TO SHEET A0.01 FOR'PROJECT NOTES' APPLICABLE TO ALL PORTIONS OF THE WORK. A. LIGHTING DIMENSION FROM FACE OF FINISH TO CENTERLINE OF FIXTURE, U.N.O. LIGHTING 2. SEE SLAB PLANS FOR CONCRETE WALL LOCATIONS, UNO. COORDINATE WITH STRUCTURAL DRAWINGS. O 24" TOWEL BARS TO BE PLACED 48" AFF MAX. B. MAINTAIN 1-HOUR FLOOR/CEILING ASSEMBLY, SEE SHEET A2.00b FOR FLOOR/CEILING ASSEMBLY 3. SEE SHEETS A0.11 AND A0.21 FOR WALL ASSEMBLIES. C. COORDINATE LOCATIONS FOR DIFFUSER AND FIRE SPRINKLER HEAD LOCATIONS. RECESSED CAN DOWNLIGHT ❑O 4. SEE ENLARGED ELEVATIONS AND WALL SECTIONS FOR ADDITIONAL EXTERIOR DETAILS. O 18" TOWEL BARS TO BE PLACED 48" AFF MAX. D. REFER TO INTERIOR ELEVATIONS FOR WALL MOUNTED LIGHTING. 5. SEE FIRE/LIFE SAFETY SHEETS BEGINNING ON SHEET G2.01 FOR LOCATIONS OF RATED CONSTRUCTION E. LIGHTING SHOWN FOR REFERENCE; REFER TO ELECTRICAL PLANS FOR LAYOUT AND SPECIFICATIONS. AND EXITING INFORMATION. O ROBE HOOK TO BE PLACES 48" AFF MAX. F. NEW CEILING GRIDS WITHIN A ROOM ARE TO BE CENTERED WITHIN THAT ROOM, U.O.N. 6. SEE SHEETS BEGINNING ON A5.01 FOR TYPICAL ACCESSIBILITY CLEARANCES. O 60" TURNING RADIUS CLEAR FLOOR SPACE G. REFER TO ELECTRICAL DRAWINGS FOR EMERGENCY LIGHTING. CIRCULAR FLUSH MOUNT 7. ALL HINGE -SIDE OF OPENINGS @ 4" FROM PERPENDICULAR WALL UNLESS OTHERWISE NOTED. H. REFER TO ELECTRICAL DRAWINGS FOR SPECIFIC FIXTURE TYPES, TYPES LISTED HERE ARE BASIS FOR 8. ENLARGED PLAN AND RCP ARE TYPICAL. SEE A2 AND A8 SERIES SHEETS FOR VARYING PERIMETER WALL DESIGN. CONDITIONS. O5 VTAC UNIT I. CENTER CAN LIGHTING OVER SHOWER, TYP. 9. FOR DOOR SCHEDULE SEE Al2 SERIES J. CENTER VANITY LIGHTING OVER COUNTER TOP, TYP. VANITY FIXTURE 10. FOR CASEWORK ELEVATIONS SEE A10 SERIES. O VTAC ACCESS PANEL PER MFR K. REFER TO SHEET A11.09 FOR TYPICAL SUSPENDED CEILING DETAILS. 11. DIMENSIONS ARE TO GRIDLINE, FACE OF (FO) CONCRETE, FO FRAMING AT EXTERIOR WALLS, FACE OF L. FINISH SURFACE IN AREAS WHERE THE PUBLIC AND RESIDENTS CAN ACCESS TO BE EQUIVALENT TO A STUD AT PARTITIONS AND CL OF DOOR AND WINDOW OPENINGS. O WASHER/DRYER LEVEL 4 FINISH; FINISH SURFACE IN UTILITY AREAS TO BE EQUIVALENT TO A LEVEL 4 FINISH. 12. FOR HANDRAIL DETAIL - SEE SHEET 16/A11.02 M. REFER TO UNIT PLAN ENLARGEMENT SHEETS FOR UNIT RCPs. 13. ALL INTERIOR UNIT WALLS IN UNITS TO BE 2X4 INTERIOR ASSEMBLY'6J.1' U.N.O. O VTAC CLOSET LOUVER, LOCATE & SIZE PER MFR CEILINGS RECOMMENDATIONS STRUCTURAL COLUMN TO RECEIVE 1/2" FURRING OAND (1) LAYER OF 5/8" TYPE X GYPSUM ON TAGGED SIDES 10 MEDECINE CABINET 11 GYPSUM SOFFITS OVER CASEWORK CFF MIPPAI I PI AN] CFF n\/FPAI I PI ANI 1/4" = 1'-0" 8'_0" T_71/7 o 8' 0" U 2 IL C-2 1/4" = 1'-0" N 3 IL C-3 1/4" = 1 '-0" GYPSUM SOFFIT & DROP CEILING UNDERSIDE OF RATED CEILING 4 RCP - IL C-1 RCP - IL C-2 RCP - IL C-3 1/4" = 1 '-0" 5 1/4" = 1 '-01, 6 1/4" = 1 '-0"