Loading...
APPROVED PLN ENG RESUB3 BLD2024-0295+SITEPlan+11.13.2024_9.10.02_AM+4616325 2GRATE FILTER SOCK WiTH OVER FLOW HOLES (TYP) iIN NOTES: CATCH BASIN 1. CONTRACTOR/DEVELOPER SHALL MAINTAIN THIS APPLICATION AT ALL TIMES DURING CONSTRUCTION PERIOD. 2. ANY SEDIMENT IN CATCH BASIN INSERT SHALL BE REMOVED WHEN INSERT IS ONE-THIRD FULL. 3. CITY INSPECTION REQUIRED ON ALL EROSION CONTROL METHODS BEFORE OTHER WORK CAN BEGIN. TEMPORARY REVISION DATE JANUARY 2018 CITY OF EDMONDS SEDIMENT TRAP STANDARD �. PUBLIC WORKS FOR CATCH BASINS DEPARTMENT DETAIL 'St. 189�) ER-902 APPROVED BY: R. ENGLISH CONTOUR LINE (TYP) ANGLE TERMINAL END UPHILL 24" TO 48" TO PREVENT FLOW AROUND WATTLE (TYP) 2"x0x24" UN -TREATED WOODEN STAKE (TYP) WATTLE p1 TRENCH, SEE N:MIN 2 �3" MIN Y 4" MAX 2" - 5" 2%2"x24" UN -TREATED WOODEN STAKE (TYP) PLAN VIEW AREA AVAILABLE FOR SPACING VARIES SEDIMENT TRAPPING SEE WATTLE SPACING (TYP) TABLE (TYP) WATTLE (TYP) SEE DETAIL SECTION A -A m WATTLE INSTALLATION ON SLOPES 8" DIAMETER MIN WATTLE DETAIL 8" DIAMETER WATTLE SPACING TABLE SLOPE MAXIMUM SPACING 1H:1V 10'-0" 2HAV 20'-0" 3H:1V 30'-0" 4HAV 40,-0" >4H:1V ONE RUN ONLY NOTES: 1. COMPOST WATTLES RECOMMENDED ON SLOPES. USE STRAW WATTLES IN PAVEMENT APPLICATION. 2. ON SLOPES, INSTALL WATTLES PERPENDICULAR TO THE FLOW DIRECTION AND PARALLEL TO THE SLOPE CONTOURS. INSTALLATION SHALL BE IN ACCORDANCE WITH WSDOT STANDARD SPECIFICATION 8-01.3(10). 3. RUNOFF SHALL NOT RUN UNDER OR AROUND ROLL. ADDITIONAL STAKING MAY BE NECESSARY TO PREVENT UNDERCUTTING. 4. WATTLES SHALL BE INSPECTED REGULARLY, AND IMMEDIATELY AFTER A RAINFALL PRODUCES RUNOFF. REMOVE SEDIMENT AND ACCUMULATIONS WHEN EXCEEDING 1/2 HEIGHT BETWEEN THE TOP OF THE WATTLE AND THE GROUND SURFACE. REVISION DATE CITY OF EDMONDS WATTLE INSTALLATION JANUARY 2018 PUBLIC WORKS STANDARD DEPARTMENT DETAIL FSf. IB90 APPROVED BY: R. ENGLISH ER-903 APPROVED BY PLANNING Nov 21 2024 Per ECDC 16.20.040(A), an Average Front Setback has been determined to equal 18.83' reduced from 25.' Average Front Setback to run with the land. Zone .. -------------- RS-12 - Corner Flag Setbacks: Required Actual Front 18.83' ------ -----' 20' =----------- Sides N=10' :-----------' ; N= 14.5: =----------• 25' 29' 10" Rear :------ ----• ---------------------- ------------ Other 25' 20.2' Height •----------• ------------- Nothing in the permit approval process shall be interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. SCHEDULE ALL INSPECTIONS THROUGH MYBUILDINGPERMIT.COM LOT 9 CB (TYPE 1) I- F 1 w - - - - - - - Ei(N) 80� 68'202.98' APPROX. AREA 0 LANDSL DE � HAZARD/ STEEP SLOPE (PER Q APPROX. AREA OF LANVSLiDE HAZARD/ I I 1E(S) 8"CONC=203.48' / EDMONDS GiS MAPPING, EE � 0) oz b STEEP SLOPE (PER EPiMOND5 Gf5 i IE(E) 4"PVC=203.88' SHADED AREA, TYP.) o wLLJ MAPPING, SHADED AREA, TYP.) I I I n .zs Q w to I---- / EX ASPHALT •'�I LOW POINT I d FOUND IRON PIPE 0 / DRIVEWAY � � p 0.11'N OF LiNE / 6/EVG 2 ` EL=189.6' `i- I o N I -_ () 1 I i i & 0.45'E / ' � _ _ - _ 1 _ N_'36,16" W 100.00' _ /FROM PROPCOR/ / 1 ' v i / w - N_88 618 20.00- I i FOUND REBAR/CAP / L moo/ L5# 9567 I / N O / / , E\7GJ2) �/y(v1 I 0 0.42'EOFLINE T I I / �wQ�rn &0.43'S FROM PROP COR I LU w d / -- CQ / I EX CONC. I I I �lSj t N / /o DRIVEWAYOZ I I L BT \ o a-/ I � I I I EXTENDED ROOF OVER yfGy`9yj,, w�$z 7-- PROPOSED N I I I I I ADDiTiON (TO ¢� - o c� PROVIDE TREE PROTECTION FENCING Cad PROVIDE WATTLES ALONG I I I I MATCH HEIGHT & SLOPE ���� \ o z / / / APPROX. LOC. OF \ EX 6" MAPLE IN PLANTER A5 REQUIRED OF EXISTING ROOF �L \ w / PROPOSED HEAT \ I BY CiTY OF EDMONDS, TO BE PROVIDED EE 7il TOP OF SLOPE ADJACENT I I MAP 1, / m T , I AT DRiP LINE OR GREATEST EXTENT TO AREA OF WORK, AND , b � , o I PUMP, VERIFY IN FIELD \ � I INSTALL SEDIMENT TRAPS I rn I T r-- I / PO551BLE OUTSIDE AREA OF WORK CB TYPE 1 POST BELOW Ca) DRVWY \ NEW IMPERViOUS \ I I I ( ) AT ALL AREA STORM T I I EX I RiM=206.36' DRAINS ADJACENT TO I I B (95.6') r----�195i9`i- PLAN ER ' 182 A (203.0') \\. PLANTER 1 **AVERAGE FRONT 5ETBACK I iE(N) 8"GONG=204.76' AREA OF WORK, TYP., PER I I I I -r • iE(E) 4"PVC=205.26' 6- ♦ - - FOR ADDITION 15 REQUESTED „ CITY OF EDMONDS REQ'S - 19'-11 11/16"+/-' I iE(5) 8 PVC=204.96 \ I i HATCH: PROPOSED PER ECDC 16.20.040.A; REFER \ TAD RiM= I , I PPITiON (HEATED PROPOSED I / TO: CALCULATIONS, THiS SHEET; I I \ 195.53' I 5 CE & COVERED �IX FRONT SETBACK** i I SURVEY SHEETS 1-3; AND WALL c I I I I DE OVER EX �I0 I EX GRASS WM I SECTION 2/A4.0 CD I I I/ GARAGE P DECK) IZ I YARD W- ' O I I I �I• I I EX. F.O.C. WALL I W I I I I I 0 I ICI (SEE 2/A4.0) I o I C L 41 EX I I I II I ', 61" MAP GRASS I - I AVF. FRONT SETBACK** I I p to I I I YARD I I I l I� I 25'-0" _- CL Q tCD I / I I EX.8.5'X16.5' I r-� MIN. IF SETBACK** i I V ' z m S I PARKING rT ' STALL I L -J I t >� -t t 2lI I I -CLiNE OF EX. 1 II 13' 1/2"+/- o I #PROX. LOP. OF EX. 55 LiNE I I I GARAGE I / EX. FRONT I o W - I I 1 I Cad GRADE FLOW (SEE S I BELOW I I / I � r"' I I SURVEY F R CONNECTION TO I EaX irn I I // 5E BACK . o N LO PRIOR LiNE; VER. LOC. iN FIELD I I I EX. LOWER FF / EX CONC. LU YIRIOR TO �TARTiNG WORK) I I EL 196.3' o PORN�H WALK & I I/ 10 i I o STEPS 1 1 I5'-0" 1 EX MAiN II I °< IJ L- I \�� I 'I 1 z 3 MIN . REAR I FLR. DECK I w Iw HiGH POINT t o I I -0 / I I STBACK BELOW PATIOII II EL = 204.13' z I / I ► I I ) I I 121711thPLN I - I z I I I I I I EDMOND5, WA 98026 \ I I LOT 8 I I< I I I PLANTER •I T I I // I I L-J �� I I EX GRASS I I `d I I I I I I YARD // I I SiTE TBM I RED WASHER = I ILl \ELEV=208.18' I I I C (195. ') / I EX (HECK II II - J m ❑( D (2035) I I I \ ACU FOUND REBAR/CAP LS# 9567 0.11'E OF LiNE & 0.34'5 FROM PROP COR SITE PLAN N 88036'18" W 100.00, SCALE: 1" =10' SiTE PLAN NOTES: 1. REFER TO SURVEY. GUTTERS/DOWNSPOUTS SHALL 2. ALL UTILITIES TO BE LOCATED AND VERIFIED PRIOR TO ANY GROUND DISTURBANCE. DRAIN TO SPLASHBLOCKS 3. REFER TO STRUCTURAL ENGINEERING DRAWINGS AND CALCULATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. FOUND REBAR/CAP LS# 9567 0.03'E OF LiNE & 0.45'5 FROM PROP COR I I \ I � \ I I OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE OWNER/CONTRACTOR RESPONSIBLE FOR LOCATING ALL ON SITE UTILITIES. RELOCATION/REVISION TO ANY UTILITIES MAY REQUIRE A SEPERATE PERMIT. I I ---------------------------------------- CULVERT iE(N) 8"PVC 1=206.36' I I I -a Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. ENGINEERING DIVISION APPROVED AS NOTED Jd,1 w4Atn,,mt 11/14/2024 VV LAND USE CODE COMPLIANCE STATISTICS ZONE: R5-12 EXISTING LOT AREA: 9,999.00 5F LESS AREA OF SHARED ACCESS EASEMENT: 1,240.00 SF TOTAL LOT AREA FOR LOT COVERAGE CALCULATIONS: 8,759.00 5F REQ'D 5ETBACK5: FRONT (EAST)* 25' PROPOSED FRONT (EAST) 16' REAR (WEST) 25' SiPE (NORTH)* 10' (OFF 30' ESMT.) PROPOSED SiDE (NORTH) O' (OFF 30' E5MT.) SiPE (SOUTH) 10, *FRONT SETBACK REQUESTED TO BE REDUCED ViA AVERAGE FRONT 5ETBACK PER ECDC 16.20.040; SiPE (NORTH) 5ETBACK REQUESTED TO BE REDUCED ViA VARIANCE REQUEST. PARKING: 2 PARKING SPACES BUILDING HEIGHT INFORMATION: BUILDING HEIGHT LiMiT: 25' REFER TO SHEETS A2.0 & A2.1 FOR DETAILED HEIGHT INFORMATION (ADDITION ROOF SHALL NOT EXCEED EXISTING RIDGE HEIGHT) LOT COVERAGE: PROPOSED LOT COVERAGE**: 35% MAiN FLOOR ADDITION & COVERED DECK**: 0 SF EXISTING LOT COVERAGE: 3,022.0 5F TOTAL PROPOSED LOT COVERAGE: 3,022.0 SF 34.5% **NO CHANGE TO EX15TiNG LOT COVERAGE PROPOSED A5 ADDITION SHALL BE BUILT ENTIRELY OVER EXISTING GARAGE & UPPER DECK WiTH OVERHANGS LE55 THAN 30". PROPOSED IMPERVIOUS AREA: ADDITION ROOF OVERHANGS: 18.2 SF PROPOSED GROSS FLOOR AREA: PROPOSED MAiN FLOOR CONDITIONED AREA: 460.8 SF EX15TiNG MAiN FLOOR CONDITIONED AREA: 1,511.0 5F EXISTING LOWER FLOOR CONDITIONED AREA: 1,455.6 SF TOTAL PROPOSED CONDITIONED AREA: 3,427.4 SF EXISTING LOWER FLOOR UNCONDITIONED AREA (GARAGE): 366.3 SF ALSO GROSS FLOOR AREA TABLE ON FLOOR PLAN SHEET AV) AVERAGE FRONT SETBACK CALCULATIONS REFER ALSO TO SURVEY SHEETS 1-3 iN PLAN SET CALCULATIONS AND APPLICATION PER EDMONDS COMMUNITY DEVELOPMENT CODE SEC.16.20.040.A PER SURVEY SHEET 1, THERE ARE 6 LOTS ALONG THE WEST SiDE OF 11th PL N BETWEEN ViEWLAND WAY AND PUGET DRIVE; LOT NUMBERS ARE 7-12. THE EXISTING FRONT 5ET13ACK5, PER SURVEYOR'S DATA (AND INCLUDING PILLARED FRONT ENTRYWAY AT LOT 8) , ARE LISTED BELOW: EX. 5ET13ACK (DEC. LOT # FEET) 7 40.40 8 13.38 9 19.20 10 21.50 11 9.50 12 9.00 AVERAGE: 18.83 (DEC. FEET) FRONT SETBACK AVERAGE EXISTING GRADE POINT ELEVATION (DEC. FEET) A 205.0 B 195.6 C 195.9 D 205.5 AVERAGE GRADE: 199.5 + 25.0 HEIGHT LiMiT: 224.5 LOT SLOPE CALCULATIONS HiGH POiNT: 204.13' LOW POiNT: 189.60' ELEV. DIFFERENCE: 14.55' HORiZ. FIST. BTWN.: 119.92' LOT SLOPE: 12.1% LU C z LIJ o CN z d U) W JJ d) L.L � LIJ ID U z z N O LIJ Q J 9716 REGISTERED ARCHITECT GST DI MICHELLE HELGESON ATE OF WASHINGTON H 2 D A R C H I T E C T U R E D E S I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P.206.542.3734 www.h2darchitects.com DATE: 3/1 /2024 REV 1: 10/16/2024 REV 2: 11 /13/2024 PERMIT SET SITE PLAN, LAND USE CODE STATISTICS RESUB Nov 13 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT