REVIEWED BLD2024-0295+Energy_Calculations+3.4.2024_1.46.24_PM+4100905BLD2024-0295 simple Heating system size: wasnington state This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop -downs and boxes that are applicable to your project. As you make selections in the drop -downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop -down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Project Information Contact Information LAWRENCE RESIDENCE H2D ARCHITECTURE + DESIGN 1217 11TH PL N 23020 EDMONDS WAY #113 EDMONDS, WA 98020 EDMONDS, WA 98020 Heating System Type: 0 All other Systems O Heat Pump To see detailed instructions for each section, place your cursor on the word 'Instructions" RECEIVED Design Temperature Mar 07 2024 Instructions Design Temperature Difference (AT) 46 DEVELLOOPMENTSERV'DES Edmonds I DE. -ENT � 1 AT =Indoor (70 degrees) -Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) Average Ceiling Height Instructions Average Ceiling Height (ft) Glazing and Doors Instructions ill-0.28 � I Skylights Instructions Insulation Attic Instructions I R-49 Single Rafter or Joist Vaulted Ceilings Instructions I No Vaulted Ceilings in this project. Above Grade Walls (see Figure 1) Instructions R-21 Intermediate Floors Instructions R-38 Fv IJ Below Grade Walls (see Figure 1) Instructions R-21 Interior Slab Below Grade (see Figure 1) Instructions No Slab Below Grade in this project. Slab on Grade (see Figure 1) Instructions I No Slab on Grade in this project. Location of Ducts Instructions No Ducts Figure 1. Above Grade REVIEWED 465 BY Conditioned Volume CITY OF EDMONDS 8.1 3,769 U-Factor X Area = UA 0.280 65 18.26 U-Factor X Area = UA 0.50 --- U-Factor X Area = UA 0.026 2,745 71.36 U-Factor X Area UA --- 319 U-Factor X Area UA 0.056 2,862 160.26 U-Factor X Area UA 0.025 3,064 76.61 U-Factor X Area UA 0.042 808 33.94 F-Factor X Length UA 0.000 --- F-Factor X Length UA --- 101 Sum of UA Duct Leakage Coefficient 1.00 360.41 Envelope Heat Load 16,579 Btu / Hour Sum of UA x AT Air Leakage Heat Load 1,872 Btu / Hour Volume x 0.6 x AT x 0.018 Building Design Heat Load 18,451 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 18,451 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 23,064 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump (07/01/13)