BLD2024-1391+Site_Plan+10.21.2024_2.26.39_PM+4572169CODE ANALYSIS CODE REQUIREMENTS: CHAPTER 7 - ALTERATIONS LEVEL 1 2021 IEBC, 2021 IBC, 2021 IMC, 2021 UPC, AND 2021 IEBC 701.2 - IMPROVEMENTS IN THE SPACE WILL NOT WSEC, 2021 NEC, AND ASSOCIATED LOCAL BUILDING MAKE THE BUILDING LESS SAFE THAN ITS EXISTING CODE AMENDMENTS. ALSO ICC/ANS1117.1-2009, AND CONDITIONS. EDMONDS CITY CODE AND COMMUNITY DEVELOPMENT IEBC 702.1 - NEWLY INSTALLED CEILING AND WALL CODE FINISHES SHALL BE MINIMUM CLASS II PER 804 OF THE IBC. NEW SUMMARY: IEBC 702.2 - NEWLY INSTALLED FLOOR FINISHES SHALL BE MINIMUM CLASS II PER 804 OF THE IBC. ZONING- BD-2 IEBC 703 - THE CURRENT LEVEL OF FIRE PROTECTION WILL BE MAINTAINED PROPERTY DESCRIPTION USE / OCCUPANCY: B - BUSINESS IEBC 704 - THE CURRENT MEANS OF EGRESS WILL BE MAINTAINED GEPHARTS 1ST ADD TO EDMONDS BLK 001 D-00 -LOTS 23 & 24 TGW S1/2 LOTS 17 THRU 22 IEBC 705 -DOES NOT APPLY INCL - EXC NELY 16FT SD LOT 17 CONVYD TO CITY ED FOR ALLEY PER VOL 88 PG 217 OF CONSTRUCTION TYPE: V-B DEEDS DAF COM MOST WLY COR SD LOT 24ALSO BEING INT OF NELY MGN JAMES ST & SELY IEBC 706 - EXISTING GRAVITY LOAD -CARRYING MGN 2ND AVE S TH N29* 00 OOE ALG SD SELY MGN 142.09FT TO NLY LN OF SLY 1/2 SD LOTS 17 STRUCTURAL ELEMENTS ARE AFFECTED LESS THAN 5% - THRU 22 TH S61* 00 OOE ALG SD NLY LN 120.04FT TO SELY LN OF SLY 1/2 SDLOTS 17 THRU 22 TOTAL BUILDING AREA: 31,626 S.F. ALSO BEING NWLY MGN OF ALLEY TH S29* 00 OOW ALG SD NWLY MGN 142.09FT TO SD NELY DOES NOT APPLY MGN JAMES ST TH N61* 00 OOW 120.04FT TPB - AKA PAR A & B CITY OF ED LLA LL-2002-67 REC AUTOMATIC SPRINKLER SYSTEM: YES IEBC 707 - ALTERATIONS COMPLY WITH WSEC. AFN 200205230310 TABLE 506.2 - ALLOWABLE AREA: 27,000 SF (SM) CHAPTER 8 - ALTERATIONS LEVEL 2 PERMITTING NOTES: ACTUAL AREA: 31,626 S.F IEBC 801 - NEW CONSTRUCTION COMPONENTS AND 1. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICIAN IN THE STATE OF WA. PRIOR SYSTEMS COMPLY WITH THE IBC. TO COMMENCING WORK, ELECTRICIAN SHALL OBTAIN THE PROPER PEMITS FROM THE CITY of EDMONDS, WA. TENANT IMPROVEMENT AREA: 3751 SF IEBC 802.2 - EXISTING VERTICAL OPENINGS IN THE BUILDING ARE NOT A PART OF THIS PROJECT. DOES NOT 2 ALL MECHANICAL WORK SHALL BE PERFORMED BY A LICENSED HVAC CONTRACTOR IN THE STATE OF WA. TABLE 504.3 -ALLOWABLE HT: 60' APPLY. PRIOR TO COMMENCING WORK, HVAC CONTRACTOR SHALL OBTAIN THE PROPER PEMITS FROM THE CITY OF ACTUAL HEIGHT: 30' IEBC 802.3 - SMOKE COMPARTMENTS - DOES NOT APPLY. EDMONDS, WA. IEBC 802.4 - INTERIOR FINISHES IN THE IMPROVED 3 ALL PLUMBING WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN THE STATE OF SPACES WILL COMPLY WITH IBC REQUIREMENTS. WA. PRIOR TO COMMENCING WORK, PLUMBING CONTRACTOR SHALL OBTAIN THE PROPER PEMITS FROM TABLE 504.4 - ALLOWABLE STORIES: 3 STORY THE CITY OF EDMONDS, WA. ACTUAL STORIES: 2 STORY IEBC 802.5 -THERE ARE NO AREAS IN THE WORK AREA ABOVE 30" OFF THE FLOOR. DOES NOT APPLY. 4. ELECTRICAL PERMIT IS A DEFERRED SUBMITTAL. NO SEPARATION OF OCCUPANCIES REQUIRED IN IEBC 803.2.5 - TENANT SPACES SHARES AN EXIT CORRIDOR WITH OTHER BUILDING TENANTS. THE EXIT 4. PROJECT IS NOT SUBJECT TO TRAFFIC IMPACT FEES UNDER ECC 3.36.040 A.1 EXCEPTION: ALTERATION IS TENANT IMPROVEMENT NOT CHANGING THE USE, DOES NOT EXPAND THE USABLE SPACE OR ADD ANY RESIDENTIAL UNITS. CORRIDOR SEVERS MORE THEN 30 OCCUPANTS. THE ACCESSIBLE MEANS OF EGRESS WORK AREA DIS REQUIRED TO BE FULLY SPRINKLERED. _ i6'Z4l M „00,00.6Z S IEBC 803.4 - AN APPROVED FIRE ALARM SYSTEM IS NOT - - OCCUPANT LOAD = 3751/150 = �26 OCCUPANTS - - -� 1- EXIT PROVIDED - ONE ACCESSIBLE EXIT REQUIRED FOR GROUP B OCCUPANCIES. IEBC 804 - DOES NOT APPLY TO OCC GROUP B. PROVIDED IEBC 805 - THE MEANS OF EGRESS IS FOR ONLY ONE NO ROOM EXCEEDS AN OCCUPANT LOAD OF MORE THAN 50 OCCUPANTS, THEREFORE NO ROOM REQUIRES TENANT. DOES NOT APPLY. THE OCCUPANCY OF THE 40 PARKING SPACES IN MORE THAN ONE (1) EXIT. BUILDING IS NOT BEING CHANGED AND THE EXISTING MEANS OF EGRESS ARE NOT WITHIN THE WORK AREA. GARAGE BELOW IEBC 805.4 - THE ALTERATION OF THE OFFICE SPACE I BUILDING - (2) ADA ;' PER IEBC -CHAPTER 3 PROVISION FOR ALL WILL INCLUDE 1 EXISTING EXIT DOOR SWINGING IN THE ACCESSIBLE NEAR COMPLIANCE METHODS DIRECTION OF TRAVEL FROM THE ROOM. THE DOOR '._ELEVATOR OPENING WILL BE EQUIPPED WITH A CLOSER AND PANIC DEVICES. w �-SWld,tlOINVN3° at THE TRAVEL DISTANCE TO THE EXIT IS more THAN 75' 53"" ""a° "°°'° �. SECTION 301 -ALTERATION COMPLIES WITH 301.3.1 IEBC 805.5 - CORRIDORS IN GROUP B OCCUPANCY ARE ---------------- ---------------- PERSCRIPTIVE METHOD (CHAPTER 5). NOT REQUIRED TO BE RATED. 3 a IEBC 805.6 - THERE ARE NO DEAD END COORIDORS A SECTIONS 302, 305, 307, 308, 309 DO NOT APPLY D WHICH IS LESS THAN THE 35-0" ALLOWED. IEBC 805.7 - ARTIFICIAL LIGHTING PROVIDED IS 6NVd NUU, YNO'U SECTION 304 - ALTERATIONS SHALL COMPLY WITH THE � °tom ('du) NItl0O lgO3! IBC REQUIREMENTS FOR NEW CONSTRUCTION COMPLIANT WITH IBC. - �° °�tkt0 0ifddV - IEBC 805.8 - EXIT SIGNS PROVIDED ARE COMPLIANT ^°°° �tl°dru vn unun 4 ALTERATIONS ARE NOT CHANGING GRAVITY OR tza - N3LtlM/l10 LATERAL LOADS, THE EXISTING BUILDING ENVELOPE WITH IBC. ,� . k 9i'Ll•tn°ntv �'Z°�.° N0 tl0,L 1'88 AND STRUCTURE ARE REMAINING AS IS. IEBC 806 - EXISTING GRAVITY LOAD -CARRYING y \ moo, I O°nnntln�oaoi ' STRUCTURAL ELEMENTS ARE AFFECTED LESS THAN 5% - �� I6f ' OO tl3 tlM B 30d DOES NOT APPLY, ';.:' - -= SECTION 306.7 - ALTERATIONS SHALL BE DESIGNED TO - IEBD 807 - ALL NEWLY INSTALLED ELECTRICAL WIRING I- -. ...�a �d JNNO M �. BE ACCESSIBLE SPACE COMPLIES WITH IBC CH. 11 AND ICC A117.1. AND EQUIPMENT COMPLIES WITH NFPA 70. PARKING PLAN SECTION 501 - FACILITY SHALL COMPLY WITH IBC CH 11 IEBC 808 -ALL ALTERED OR NEWLY INSTALLED 4 1" = 30'-0" UNLESS TECHNICALLY INFEASIBLE MECHANICAL EQUIPMENT COMPLIES WITH 808.1 AND 410.6.2 - ACCESSIBLE MEANS OF EGRESS NOT 808.2. �I REQUIRED IEBC 809 - THE NUMBER OF PLUMBING FIXTURES IS 74 LF ONE ACCESSIBLE EXIT PROVIDED BEING INCREASED AND COMPLIES WITH THE IPC. d 410.7 - ALTERATIONS INCLUDE KEEPING THE IEBC 810 - ALTERATIONS COMPLY WITH WSEC.d FACILITY ACCESSIBLE - THE PRIMARY FUNCTION d� (BUSINESS) IS ACCESSIBLE. a a a a 0- a 410.8 - THE SPACE HAS AN ACCESSIBLE ENTRANCE PORTABLE FIRE EXTINGUISHERS TO BE PROVIDED AND FEC INSTALLED PER SECTION 906 a a a a a a a a a a 0 0 0 0 0 a 441- 11 PER IEBC - CHAPTER 5 PRESCRIPTIVE METHOD SECTIONS 502, 504, 505, 506, 507 DO NOT APPLY SECTION 501 - THE PROJECT DOES NOT REDUCE COMPLIANCE OF THE BUILDING STRUCTURE WITH THE IBC. SECTION 503.3 AND 503.4 - ALTERATIONS ARE NOT CHANGING GRAVITY OR LATERAL LOADS, THE EXISTING BUILDING ENVELOPE AND STRUCTURE ARE REMAINING AS IS. PER IEBC - CHAPTER 6 CLASSIFICATION OF WORK SECTIONS 602, 604, 605, 606, 607 DO NOT APPLY SECTION 603 - PROJECT CHANGES QUALIFY AS LEVEL 2 ALTERATIONS PER IEBC 603.1 COMPLIANCE WITH CH 7 LEVEL 1 ALTERATIONS AND CH 8 REQUIRED MEANS OF EGRESS ONE EXIT PROVIDED (ONE ACCESSIBLE) THE TRAVEL DISTANCE FROM ANY POINT IN THE SPACE TO AN EXIT IS LESS THAN 75 FEET. EXIT ACCESS k-j-1 a `TOTAL OCC LOAD = 26 41 a a a a a a a a a a a a 4-- F1q 4 4 4b a a a 4 i J� CODE PLAN 3/32" = V-0" SCOPE THIS PROJECT CONSISTS OF MINOR ALTERATIONS TO AN EXISTING OFFICE SPACE FOR A MECHANICAL/ELECTRICAL/PLUMBING ENG DESIGN FIRM MOST OF THE INTERIOR WALLS AND PARTITIONS ARE BEING RETAINED IN PLACE. NEW FLOOR FINISHES AND WALL PAINT WILL BE PROVIDED. (2) NEW OFFICE DOORS WILL BE INSTALLED. BREAKROOM CASEWORK WILL BE INSTALLED. NO EXTERIOR WORK IS BEING DONE. DRAWING SYMBOLS: 1 A7.02 2 INTERIOR ELEVATION 4 CALLOUT MARK 3 Room Name 101 ROOM TITLE TAG i 101 DOOR TAG 1t WINDOW TAG XXX WALL TYPE TAG Edmonds 0 >E) P' Channel Market Q bor Square Dental 0 �OG34:� REFERENCE NORTH ARROW B•a.•:e::s Landing South a� Q,3 tirackett's / ePr/S r 6Prrsr Saltsh Insurance Group Great ir,�a�ce M Agency �d sr CID av C r V �d1"es SO Edmonds Ferry Terminal VlN j Practical Oof Edmonds Now acceptiing QArt wot,I. : h Live traffic - - . CLEAR SPACE FLOOR (C2)VICINITY MAP - EDMONDS, WA REQUIREMENT 1" = 60'-0" i ~r .0 ................... .e .s r SITE PLAN 1 " = 20'-0" FROM STRE 10L _J sr p 2 P r r a� �� Fa �Q as Sprague St �a sr eP// Sr �C h 49 r Rowan Kaiser Motto R 0 Mortgage Group Bell St Locai Mortgage Professionals ualey w z a, > a z a r �o Z i� a > G_ "0 Md/n s s r `O N PROJECT SITE -Dayton Sty =D_aylon'St_Q F -- 0 rn a M�°'e 5• a' L M TRASH AND RECYCLE SERVICED FROM ALLEY 123 2ND AVE S, EDMONDS WA, 98020; SUITE 200 PARCEL # 00454800102000 D 10241 RECi1STMED ARCHITECT I.AURA M. STRAUSg STATE OF WASHINOTOId 0 0 E m OV CV � v00� N a',j Q NQC N vi r Ul -6, M o ° Lr1 W O 0 G CN� 0 0 2)Q'- N J 4J 0 N O 00 L.I.J 0-) U � CD LL. Z LL C/j w 0 0 W � C/� � W p Z � w (D Z ui Cl) (D w o C/) Q W p 0 Z N M N Ir- REVISION SCHEDULE # DESCRIPTION DATE JOB NO. 2024-017 DATE 28 SEPT 2024 DRAWN LMS REVIEWED LMS SHEET NAME COVER SHEET SHEET NO. Al