Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
BLD2024-1583_Manufacturer_Specifications_and_Installation_Instructions_12.3.2024_8.32.12_AM_4648678
Job Name: System Reference: Date: r7 ELEMW .,,�alllllllllllll°I'Illlls�l��,i �IlilllllllllllllllllllllilllilIIIIIIIII�I, IIIIII!!!!!!!.lIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIV . A -- �IIIIIIIIIIIIIIIIIIIIIIIIlIIIIIIIIIIIIIIIIIIII�' • ''E�I01111111111111111!liiill'llllilliil'' OR— to FEATURES • Variable speed INVERTER -driven compressor • Optional base pan heater • Quiet outdoor unit operation as low as 56 dB(A) • High-pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection • Blue Fin anti -corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life o Rated for 2,000 hours spraying time per ASTM B117 Standard Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Cooling' (Non -Ducted // Mix (Low -static) // Ducted (Low -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 43,000 // 41,000 // 39,000 41,000 H 39,000 Rated Capacity BTU/H BTU/H W 40,500 // 38,950 H 37,400 38,450 H 36,400 12,600 // 12,600 // 12,600 14,850 // 17,100 4,775 // 4,683 H 4,590 4,683 // 4,590 Minimum Capacity Maximum Power Input Rated Power Input W 4,403 114,258 // 4,112 4,224 114,045 Power Factor (208V, 230V) % 99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 1 99.0, 99.0 // 99.0, 99.0 Heating at 47°F' (Non -Ducted // Mix (Low -static) H Ducted (Low -static) i Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H BTU/H 53,600 // 52,600 // 51,600 47,300 // 41,000 45,000 // 43,000 // 41,000 43,000 // 41,000 Rated Capacity Minimum Capacity BTU/H 11,400 // 11,400 // 11,400 113,850 // 16,300 Maximum Power Input W 6,160 // 6,215 H 6,270 6,215 H 6,270 Rated Power Input W 3,575 // 3,519 // 3,463 i 4,048 // 4,520 Power Factor (208V, 230V) % 99.0, 99.0 // 99.0, 99.0 // 99.0, 99.0 199.0, 99.0 H 99.0, 99.0 Heating at 17°F3 (Non -Ducted // Mix (Low -static) H Ducted (Low -static) i Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 30,500 // 29,800 // 29,1001 29,800 // 29,100 Rated Capacity BTU/H 24,400 // 23,700 // 23,000 i 23,700 // 23,000 Maximum Power Input W 4,750 // 4,991 // 5,231 i 4,991 // 5,231 Rated Power Input W 2,943 H 2,906 // 2,869 i 3,247 // 3,550 Heating at 5°F4 (Non -Ducted // Mix (Low -static) // Ducted (Low -static) i Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 25,000 // 25,000 // 25,000 i 25,000 // 25,000 Maximum Power Input W 5,000 // 5,200 // 5,400 5,200 // 5,400 Efficiency SEER2 19.7 // 17.45 // 15.2 117.45 // 15.2 EER21 9.2119.1//9.09.1119.0 HSPF2 (IV) 9.2 H 9.1 // 9.0 8.75 // 8.3 (Non -Ducted // Mix (Low -static) // Ducted (Low -static) i Mix (High -static) // Ducted (High -static)) COP at 47°FZ 3.68 // 3.57 // 3.46 i 3.17 // 2.66 COP at 17°F at Maximum Capacity' 1.88 // 1.76 // 1.63 11.76 // 1.63 COP at 5°F at Maximum Capacity° 1.47 // 1.42 // 1.36 1.42 // 1.36 ENERGY STAR® Certified No // No // No i No // No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor -Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size A 40 Recommended Wire Size (Indoor - Outdoor) AWG 14 Minimum Circuit Ampacity A 32.5 Maximum Overcurrent Protection A 40 Fan Motor Full Load Amperage A 2.43 Outdoor unit Airflow Rate (Cooling / Heating) CFM 2,150 / 2,550 Refrigerant Control LEV Defrost Method Reverse Cycle Heat Exchanger Type Plate Fin Coil Heat Exchanger Coating Blue Fin Coating Sound Pressure Level, Cooling' dB(A) 56 Sound Pressure Level, Heating2 dB(A) 58 Compressor Type DC INVERTER -driven Twin Rotary Compressor Model MNB33FBTMC Compressor Rated Load Amps A 20 Compressor Locked Rotor Amps A 28.8 Compressor Oil Type // Charge oz. FV50S // 37.2 Base Pan Heater Optional Unit Dimensions W: In. [mm] 37-13/32 [950] D: In. [mm] 13 [330] H: In. [mm] 41-17/64 [1,048] Package Dimensions W: In. [mm] 41-3/8 [1,050] D: In. [mm] 17-3/8 [440] H: In. [mm] 48-7/16 [1,2301 Unit Weight Lbs.[kg] 189 [86] Package Weight Lbs.[kg] 218 [99] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum'^) °FDB 115 / 14 Cooling Thermal Lock -out / Re -start Temperatures °FDB 10.4 / 14 Heating Intake Air Temp (Maximum / Minimum) °FWB 65 / 5 Heating Thermal Lock -out / Re -start Temperatures °FDB 1.4 / 5 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low, mid and high external static pressure tests conducted at 0.1, 0.3 and 0.5 in.w.g. respectively, according toAHRI 2101240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Refrigerant Type R410A Pre -Charged Refrigerant Amount Lbs,oz 8.0,13.0 Maximum Pre -Charged Piping Length Ft. [m] 98.0 [30.0 Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.216 [20 Indoor unit connection Maximum Number of Connected IDU 5 Minimum Number of Connected IDU 2 Minimum connected capacity BTU/H 12,000 Maximum connected capacity BTU/H 51,000 Piping Liquid Pipe Size O.D. (Flared) In.[mm] A,B,C,D,E: 1/4 [A,B,I Gas Pipe Size O.D. (Flared) In.[mm] A: 1/2; B,C,D,E: 3/8 [A: 12. Total Piping Length Ft. [m] 262 [80] Maximum Height Difference, ODU above IDU Ft. [m] 49 [15] Maximum Height Difference, ODU below IDU Ft. [m] 49 [15] Farthest Piping Length from ODU to IDU Ft. [m] 82 [25] Maximum Number of Bends for IDU 80 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 2Heating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 41-leating at YF (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. I5°F DB - 115'F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Low, mid and high external static pressure tests conducted at 0.1, 0.3 and 0.5 in.w.g. respectively, according toAHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide bdr Outlet Guide (1 Piece) ❑ PAC-SH96SG-E Refrigeration Ball Valve - 1/2" ❑ BV12FFS12 Refrigeration Ball Valve - 1/4" ❑ BV14FFS12 Ball Valve Refrigeration Ball Valve - 3/8" ❑ BV38FFS12 Refrigeration Ball Valve - 5/8" ❑ BV58FFSI2 M-Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) 1-1CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Drain Socket Drain Socket ❑ PAC-SG60DS-E Hail Guards Hail Guard ❑ HG-Al M-NET Converter M-NET Converter ❑ PAC-IF01MNT-E 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ElSW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW164-50 Condensing Unit Mounting Pad: 16" x 36" x 3" ElULTRILITEI Mounting Pad Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Optional Defrost Heater Optional Defrost Heater ❑ PAC-645BH-E Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ElMAC-A456JP-E Port Adaptor Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Single Fan Stand ❑ QSMS1801 M 4" Single Fan Stand ❑ QSMS2401 M Stand Condenser Wall Bracket ❑ QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit Stand — 12" High ❑ QSMS1201 M Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. 1.FREE SPACE E a `o v 0 E O E 3-15/16" or more ° o� i a 0 0 2.SERVICE SPACE FORM# MXZ-5C42NA4 - 202311 SPACE L0 — Conduit plate Under Unit: inch (mm) 1I0 1/4'(06.35 )FLARE GAS 3/8'(99.52 )FLARE 1I0 1/4'(06.35 )FLARE GAS1/2'(e12.7 )FLARE nnector 1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com C Et! US Intertek Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.