Loading...
APPROVED RESUB1 BLD2024-1540+ARCH PLANS+12.10.2024_7.56.00_AM+4661366Designer: Kirsten Dumo Satterberg Desonier Dumo sdd@satterbergdesign.com Phone:206.232.1830 Shared walls are 6" CMU Shared walls are 6" CMU PROJECT DESCRIPTION: SHEET TITLE: Contractor and supplier must verify all dimensions on site prior to ordering of any Hines Residence Existing Floor Plan materials. Drawings are for reference only and Edmonds, WA not for structural changes or permit submission. SCALE: Plans: 1/4" = 1'-0" Elevations: 1/2" = 1'-0" Paper size: 11'. x 17" DATE: Page 12/9/24 1 Shared walls are 6" CMU Kitchen Exhaust Vent: Hood has not yet been selected, but will NOT exceed 399 CFM 16'-9 7/16" 110" 51" �� NO CHANGES TO r EXISTING framing other than removal of the two 3of walls in the kitchen. I I I 1 Wat II wuntertop etlge p� KITCHEN o LIVING �a '6 P th DINING 2539FX 3068 ,Q Ceiling height yQ 7' 5-1/2" 59 — — — 1/2„ 33„ Ceiling height m m a 7' 9-3/4" o5 Kn; 30" wide 1 base cabinet 6'- " �v off_ 1 ice, F 271/2" " 37 3/4" 39" 32 1 /4"--I E N TR Lo oo n � Ceiling height v 7'-9.5" M 6'-3 1 /4" 2668 2668 36 1 /8" 5068 5'-10 112" 510311 LS 34311 LS 3068 CLOSET CLOSET (i)s � CLOSET ET - Za 10'-1 1/4" 0 71 9'-4 1 /4" HALL 14' N 3 38" 1 N M E a) ® 0 46 3/4" � N o o El ctrical r` anel M 2464 i 21" 21" 2468 i 2068 30 3/4" v ih a — — — CLOSETN o BEDROOM N i s i BEDROOM o -- —� W BATH 128 3/8" 1 BATH ® �� J U 313/16„ 30" 4'-101/8" 7'-43/4" Both Bathroom Exhaust Fans: Panasonic FV0511VQ1 with variable switched CFM of 50/80/110 Both new showers: Shared walls are 6" CMU 3/8" Tempered glass for the shower proposed showers Designer: Kirsten Dumo Satterberg Desonier Dumo sdd@satterbergdesign.com Phone:206.232.1830 PROJECT DESCRIPTION: SHEET TITLE: Contractor and supplier must verify all dimensions on site prior to ordering of any Hines Residence Proposed Floor Plan materials. Drawings are for reference only and Edmonds, WA not for structural changes or permit submission. SCALE: DATE: Page Plans: 1/4" = 1' 0" 12/9/24 2 Elevations: 1/2" = 1'-0" Paper size: 11'. x 17" Designer: Kirsten Dumo Satterberg Desonier Dumo sdd@satterbergdesign.com Phone: 206.232.1830 Ensuite Bathroom electrical: - Existing switching to remain as is, change fan switch to timer. - Lower side wall switch and outlet as needed for medicine cabinet. - Existing sink outlet is GFCI. - Add GFCI outlet at toilet for future bidet seat. - Add in -floor heat, if possible. - Replace existing fan/light/heat with new fan/light. Lighting plan shows owner requested lighting and electrical changes only, any existing lighting and electrical not noted should remain as is. Hall Bathroom electrical: - Existing switching to remain as is, change fan switch to timer. - Lower side wall switch and outlet as needed for medicine cabinet. - Change existing outlet at sink to be GFCI. - Add GFCI outlet at toilet for future bidet seat. - Add in -floor heat, if possible. - See specs for notes regarding exhaust fan/light. PROJECT DESCRIPTION: SHEET TITLE: Contractor and supplier must verify all dimensions on site prior to ordering of any Hines Residence Proposed Lighting Plan materials. Drawings are for reference only and Edmonds, WA not for structural changes or permit submission. SCALE: DATE: Page Plans: 1/4" = 1'-0.1 12/9/24 3 Elevations: 1/2" = 1'-0" Paper size: 11" x 17"