APPROVED RESUB1 BLD2024-1540+ARCH PLANS+12.10.2024_7.56.00_AM+4661366Designer: Kirsten Dumo
Satterberg Desonier Dumo
sdd@satterbergdesign.com
Phone:206.232.1830
Shared walls are 6" CMU
Shared walls are 6" CMU
PROJECT DESCRIPTION:
SHEET TITLE:
Contractor and supplier must verify all
dimensions on site prior to ordering of any
Hines Residence
Existing Floor Plan
materials. Drawings are for reference only and
Edmonds, WA
not for structural changes or permit submission.
SCALE:
Plans: 1/4" = 1'-0"
Elevations: 1/2" = 1'-0"
Paper size: 11'. x 17"
DATE:
Page
12/9/24 1
Shared walls are 6" CMU Kitchen Exhaust Vent:
Hood has not yet been selected,
but will NOT exceed 399 CFM
16'-9 7/16" 110"
51"
��
NO CHANGES TO
r
EXISTING framing other
than removal of the two
3of
walls in the kitchen.
I
I
I
1
Wat II wuntertop etlge
p�
KITCHEN
o
LIVING �a
'6 P th
DINING
2539FX 3068
,Q
Ceiling height yQ
7' 5-1/2" 59
— — —
1/2„
33„
Ceiling height m m a
7' 9-3/4" o5 Kn;
30" wide
1 base cabinet
6'- "
�v
off_
1
ice,
F
271/2"
"
37 3/4" 39"
32 1 /4"--I
E N TR Lo
oo n
� Ceiling height
v
7'-9.5"
M
6'-3 1 /4"
2668
2668
36 1 /8"
5068
5'-10 112"
510311 LS 34311 LS 3068
CLOSET
CLOSET
(i)s
�
CLOSET
ET
-
Za
10'-1 1/4"
0
71
9'-4 1 /4"
HALL
14'
N 3
38"
1 N
M E a)
®
0
46 3/4"
�
N
o o
El
ctrical
r`
anel
M
2464
i 21"
21"
2468
i
2068
30 3/4"
v
ih
a
— —
—
CLOSETN
o BEDROOM
N i
s
i
BEDROOM o
--
—�
W
BATH 128
3/8"
1 BATH
®
��
J
U
313/16„
30"
4'-101/8" 7'-43/4"
Both Bathroom Exhaust Fans:
Panasonic FV0511VQ1 with variable switched CFM of 50/80/110
Both new showers:
Shared
walls are 6" CMU
3/8" Tempered glass for the shower proposed showers
Designer: Kirsten Dumo
Satterberg Desonier Dumo
sdd@satterbergdesign.com
Phone:206.232.1830
PROJECT DESCRIPTION:
SHEET TITLE:
Contractor and supplier must verify all
dimensions on site prior to ordering of any
Hines Residence
Proposed Floor Plan
materials. Drawings are for reference only and
Edmonds, WA
not for structural changes or permit submission.
SCALE: DATE:
Page
Plans: 1/4" = 1' 0"
12/9/24 2
Elevations: 1/2" = 1'-0"
Paper size: 11'. x 17"
Designer: Kirsten Dumo
Satterberg Desonier Dumo
sdd@satterbergdesign.com
Phone: 206.232.1830
Ensuite Bathroom electrical:
- Existing switching to remain as is, change fan
switch to timer.
- Lower side wall switch and outlet as needed for
medicine cabinet.
- Existing sink outlet is GFCI.
- Add GFCI outlet at toilet for future bidet seat.
- Add in -floor heat, if possible.
- Replace existing fan/light/heat with new fan/light.
Lighting plan shows owner requested lighting and electrical
changes only, any existing lighting and electrical not noted
should remain as is.
Hall Bathroom electrical:
- Existing switching to remain as is, change fan
switch to timer.
- Lower side wall switch and outlet as needed for
medicine cabinet.
- Change existing outlet at sink to be GFCI.
- Add GFCI outlet at toilet for future bidet seat.
- Add in -floor heat, if possible.
- See specs for notes regarding exhaust fan/light.
PROJECT DESCRIPTION:
SHEET TITLE:
Contractor and supplier must verify all
dimensions on site prior to ordering of any
Hines Residence
Proposed Lighting Plan
materials. Drawings are for reference only and
Edmonds, WA
not for structural changes or permit submission.
SCALE: DATE:
Page
Plans: 1/4" = 1'-0.1 12/9/24 3
Elevations: 1/2" = 1'-0"
Paper size: 11" x 17"