Loading...
For Reference-BLD2023-0811+Grading Drainage_Plan+6.29.2023_10.22.18_AM+3639588NE 1/4, SW 1/4, SECTION 07, TOWNSHIP 27 NORTH, RANGE 04 EAST, W.M. 0 FOUND IRON PIPE 0.30'W OF LINE & 0.41'S FROM PROP COR 6 CED 0 w 0 U U) m N 85 O9 00 0 T / ► / 8"MAP i \ 24" IF0 v PROPOSED CONCRETE PATIO 12"CHO\ FFE: 52.3 2 ROOF AND -ENCE \ - FOOTING DRAIN 0.7 W / \ \ / PROPOSED CONCRETE PATIO FFE: 518 R/F i R/F �R/F \ \ DECK FFE TO BE 30 .--__ V A OR LESS ABOVE R/F �/F R/F --- \ \ FINISHED GRADE R/F R/F R/F R/F _---_---- / / PROPOSED POOL DECK ' R/F R/F R/F � -R/F FFE: 46.7 �) ---� z AREA DRAIN FOR PLIN-Z017-0Q20 PROPOSED / PATIO RUNOFF. TIE PARTIALLY j INTO ROOF DRAIN LINE % 4"BI j COVERED PATIO FC ° PROPOSED POOL FFE: 51.8 / i PROPOSED CONCRETE I � I , 8" NYLOPLAST DRAIN DRIVEWAY AND PARKING BASIN WITH OPEN GRATE FFE: 51.8 0.9 RIM: 51.cr 8 � 8" NYLOPLAST DRAIN IE (6" SW): 45.4 TRENCH DRAIN TO BASIN WITH OPEN GRATE 9 LF 6" PVC PLANTER 8" NYLOPLAST DRAIN COLLECT DRIVEWAY OFF RIM: 46.7 a BASIN WITH OPEN GRATE e IE (6 NE,S): 45.2 @ 2.0% LL TOW: 49.3 RIM: 51.8 `r BOW: 42.4 24 LF 9' TALL MAX HEIGHT IE (TRENCH DRAIN, E): 51.3 17 LF - 6" PVC @ CONCRETE RETAINING IE (6", SE): 50.3 / 0.5% MIN. TO TIE WALL (SEE STRUCTURAL) 1.0' INTO ROOF DRAIN s a / �/a TOW: 51.3 PROPOSED HOUSE CONNECT TO -P Zcc I 7 LF - 6" PVC / BOW: 42.4 FFE: 51.8' ROOF DRAIN LINE ° i c� I G I ° @ 0.5% MIN O� TOW: UPPER FLOOR FFE: 62.1' /4' BOW: 47.4 fi I a o ' ° / Q �p�� � LOWER FLOOR FFE: 42.4, ° I O a TOW: 51.3 TYPE I CB, SOLID LID SDCO, TYP BOW: 48.4 BOW: 42.7 I °4 cL RIM: 47.4 IE (6" N): 42.1 P / TOW: 47.9 51 9 \` a Dc PROPOSED ACCESS 17"CEDo FENC OR 0.9'N F LINE & 0.5' FROM WIRE FENCE ON LINE 10"CED0 OP C R I LOT 1 PLN-2017-0020 ► ► ► I on z 1 E 182.00' REBAR/ AP I � 5"FI R FENCE 2 t' I 0.8'E TOW: 56.0 BOW: 52.3 I > I 11 4 LF 3.7' TALL MAX HEIGHT CONCRETE RETAINING WALL / I II / I �I I� I IE (6" SW): 42.1 ° \ �. / BOW: 47.4 TO BASEMENT �� a / BOT: 40.0 • I TOW: 48.9 FIFE: CONNECT TO 09"FIR ° 1 2 v � ° BOW: 42.4 ROOF DRAIN LINE � ° ACCESS RUNOFF. TIE INTO MAIN ENTRY I C3.2 C3.2 \I AREA DRAIN FOR BASEMENT 0 o \ 4 z o ss ROOF DRAIN LINE / FFE: 51.8 // \ K 26 LF 8' TALL MAX _ _ / ° ° a i \ HEIGHT CONCRETE 7 SD / ' MIN -I RETAINING WALL I a ° I T j 26"CEO. J 11 "CEDE / O O / 32' II � / TOW: 56.9 / BOW: 51.8 . 0 / o 1.3' O TOW: 57.9 BOW: 52.3 "FIR 6"FI R M AP 0 16"MAPO 7"FIR PROPOSED DRIVEWAY / 12 LF - 6" PVC 10.0 �/a I /// (SEE STRUCTURAL) , A V b o ` @ 0.5% MIN /(23.0) a I - TOW: 54.4 BOW: 51.8 ° FENCE a- 59 LF 6' TALL MAX 0.5' :�..:....I 50 51.8 ° I�:: ; : P/ TOW: 48.9 ss SS" ( ° HEIGHT CONCRETE AP �.. . • • . RETAINING WALL BOW: 42.4 TOW: 50.0 (SEE STRUCTURAL) BOW:42.4 a GAS TOW: 14"MA� 10.0' / : ��: Q BOW: 51.8 8" NYLOPLAST DRAIN < TOW: 57.4 / .::: . / BASIN WITH OPEN GRATE N FOUND TACK/LEAD 12"CED MIN / ! :. / 0 : • ;r .:. / / 15"MAP 63 LF 3' TALL MAX RIM: 51.6 a BOW: 55.2 g"CE O LS# 14490 / %: • : ' FE CE D 0.1'W 0.05'N OF LINE & / HEIGHT CONCRETE IE (6 SE): 50.1 29.0' x 7.0' x 4.0' / � / F OM RO '0.12'W FROM PROP COR 1.3' �P INFILTRATION TRENCH G 1 CED RETAINING WALL12"C CED0a 26 FI -0TOP:45.0 1 10"CEFENCE COR I BOT: 41.0 ' / 0 a i TOW: 57.5 \ 1.2'E OF LINE \ �P GROUNDWATER:37.3± 8" BOW: 57.0 / & 3.9'N FROM v� ��� (SEE GEOTECH REPORT) 8"FI26 85•09'00" E 182� 11"C D PROP COR v / y>B � N 10" � � �, 10' MIN RADIUS I 0 24" ,17" ED a 8»MAP 4 /CO 12"BIR0 _ C 6" ED O d 8"CH P 0 10 MA MAP CLUS tv wan / 811C 0� 010"MAP0 2)9 (2)8" P a 0 Cn b 0 - 0 15"CED0 SSC I `� M ST (2)§NAP / `I PROPOSED DRIVEWAY G 30"FIR RIM: 51.3 i � w w APPROACH SHALL NOT EXCEEDFOUND IRON PIPE O / IE: 44.15 I w W 24 IN WIDTH. DRIVEWAY 8„DI W 24.0 0.11 W OF LINE & I i/ ` W� W APPROACH MATERIAL SHALL BE 0.18'S FROM PROP COR z ' W ASPHALT FROM PAVED ROAD l 0 2 0 I W� TO PROPERTY LINE AT MIN o �� W�W ASPHALT o APPROX. LOCATION PAVEMENT wv 0 o SW WI PER RECORDS (TYP) �w \ \ W-\N �� RICK PL \ \ _SS_SS- w- I � FR E� E _ t L ` \ v ` psis SS�SS� S BASIS OF BEARIN�S \ �� SS SS \ ( i 9'00" E 948.67' \MEAS. _Ss SS SS SD - ) � � I N 85 0 � SD I (948.65� SS E� R2) SS SS Ss SD SD 144.54' / __--Ss SsI SS - Sp SD � SD SD CB (TYPE 1) �SS�SS�SS SD IE(W) RIM=60.55' SS SS \ SD CB TYPE 1) IE(W) 12"PVC=58.75' S SS \ / P IE(E) 12"CONC=58.95' SS �� TYPE 1) � � � SD RIM=53.10 � P� P � PP ;S RIM=47.23' - SD SD IE(W) 12"CONC=50.00' P � P� pp_ P IE(W) 12"CONC=45.43'� C-n SD / IE(E) 12"GONG=51.50� p� pP� P p ♦ GRADING AND DRAINAGE PLAN 06 SCALE: 1" = 10' GRADING AND DRAINAGE PLAN NOTES: 1. SOILS REPORT REPORT NUMBER: 1021818 PREPARED BY: NELSON GEOTECHNICAL ASSOCIATES, INC DATED: FEB 02, 2018 2. A MINIMUM OF T HORIZONTAL SEPARATION AND V VERTICAL SEPARATION IS REQUIRED BETWEEN DRY UTILITIES (POWER, GAS, PHONE, CABLE, ETC) AND SEWER, WATER AND STORM, AND A MINIMUM OF 5' HORIZONTAL SEPARATION AND 1' VERTICAL SEPARATION FROM ANY CITY OWNED LINES. 3. ALL DISTURBED AREAS TO BE COMPOST AMENDED PER 2019 SWMMWW BMP T5.13. SEE DETAIL 4/C3.2. 4. A TYPE II MANHOLE IS REQUIRED WHENEVER RIM TO INVERT EXCEEDS 51 . 5. A MINIMUM OF 2' OF COVER IS REQUIRED FOR ALL PIPES LOCATED UNDER DRIVABLE SURFACES AND 1' OF COVER UNDER LANDSCAPE AND OTHER HARD SURFACES. F 10 0 5 10 20 GRADING QUANTITIES TOTAL EXCAVATION (CUT) - 1,100 CU YDS TOTAL EMBANKMENT (FILL) - 755 CU YDS TOTAL 1,855 CU YDS THE QUANTITIES SHOWN ABOVE ARE FOR THE PERMIT PROCESS ONLY. THESE VALUES ARE APPROXIMATE. DO NOT USE FOR BIDDING, PAYMENT, OR ESTIMATING PURPOSES. PAVING LEGEND NEW ASPHALT/UTILITY SAWCUT NEW CONCRETE IMPERVIOUS SURFACES SURFACE SURFACE AREA (SF) STORMWATER CONTROL MEASURE NEW BUILDING 4,714 RUNOFF ROUTED TO INFILTRATION TRENCH THROUGH ROOF DRAINS. NEW DRIVEWAY 1,441 RUNOFF COLLECTED VIA TRENCH DRAIN AND ROUTED THROUGH PERIMETER DRAINS TO INFILTRATION TRENCH. NEW PATIOS & WALKWAYS 1,431 COLLECTED BY AREA DRAINS AND ROUTED THROUGH PERIMETER DRAINS TO INFILTRATION TRENCH. NEW POOL THE POOL OVERFLOW IS TO BE TIGHTLINED TO THE ONSITE 492 SANITARY SEWER SYSTEM PER THE 2019 SWMMWW S433. NEW DWY (ROW) 250 NEW OFFSITE DRIVEWAY WILL SHEET FLOW WITHIN ROW. NOTE: TOTAL NEW/REPLACED IMPERVIOUS SURFACES ON -SITE ARE 8,328 SF 4" DIA PERFORATED PVC PIPE WITH 6" OF 1" MINUS GRAVEL ALL AROUND, WRAPPED IN NON -WOVEN GEOTEXTILE FABRIC, SLOPE AT 0.5% MIN. TURN DOWN PERFORATIONS AS SHOWN 6" DOWNSPOUT TIGHTLINE TO CONVEYANCE SYSTEM @ 0.5% MIN. PLACE NEXT TO FOOTING DRAIN OR AS SHOWN ON GRADING & DRAINAGE PLAN (CONTRACTOR MAY LOCATE ON EITHER SIDE OF FOOTING DRAIN) LINE OF MAX EXCAVATION. IF SOIL IS OVEREXCAVATED, REPLACE WITH LEAN MIX CONCRETE 8" MIN FROM WOOD. SEE STRUCTURAL DRAWINGS I16Z9111111I►[e / 1I FOOTING AND ROOF DRAIN SECTION SCALE: NTS FINISHED LEVEL OF CONCRETE SURROUND TO BE APPROX 1/8" ABOVE TOP OF CHANNEL EDGE EXPANSION JOINT INSTALL ACO DRAIN MODEL K100S OR EQUAL CONCRETE 3000 PSI MIN BEDDING LAYER SURFACING PER :IVIL DRAWINGS m TRENCH DRAIN (IN CONCRETE SCALE: 1" = 1'-0" ASPHALT CONCRETE WEARING COURSE HMA CLASS 1/2" PG 64-22 N (WSDOT STD SPEC 5-04.1) o+ in 0 00 000 00 0� nO 000 000 0 00 0, 0 00 0.0 00 0.0 00 0.0 o°0 00 0°0 00 0°0 00 0°0 00 00o 69 00069 00069 00069 I -III I I -III -III -III -III -I III -III -III -III -III -I I -III I -III -III -III -I - IIMII III=III=III=III=IIIII I=1 CRUSHED SURFACING BASE COURSE (WSDOT STD SPEC 9-03.9(3)) SUITABLE NATIVE MATERIAL FILL; TOP 12" COMPACTED TO A MINIMUM OF 95% RELATIVE COMPACTION USING AASHTO T-180 (ASTM D1557). UNSUITABLE NATIVE MATERIAL SHALL BE REPLACED TYPICAL PAVEMENT SECTION SCALE: 1" = 1'4' XXXXXXX-XXXX APPROVED FOR CONSTRUCTION CITY OF EDMONDS DATE: BY: CITY ENGINEERING DIVISION ENGINES RING, 250 4TH AVE. S., SUITE 200 EDMONDS, WASHINGTON 98020 PHONE (425) 778-8500 FAX (425) 778-5536 FOR REFERNCE [I, ONLY SEE #BLD2023-0799 FOR RELATED BUILDING PERMIT APPLICATION 11 J H H Z o co � N w w Q 0- m N Q 0 O Y Q DESIGN: NAT DRAWN: JCP CHECK: JPU JOB NO: 23038.20 DATE: 06/1 6/23 �l..IJ V a Z La Q (n U U J N O Q CL Z LLI � W p Y U_ a Z 0 V) WLLI Q o � W 0 ^ (^ Z Z � Q Z w``z Z _ U o La LL w 00 La V ^ C3ml