Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB1 BLD2023-0811+OTHER+3.5.2024_9.12.59_AM+4103154
' The following documentation shall be available on on site for the building inspector: ■ '- ❑ COE APPROVED ARCHITECTURAL PLAN SET I 1 .1"CD ■ IXI COE APPROVED STRUCTURAL PLAN SET ; I t 9.511CO 1 ■ COE REVIEWED CALCULATION PACKET ' I ' [W] ENERGY CREDIT WORKSHEET 1 _ _ _ _._.- T'-'- nSITE PLAN 60" tall Chain Link Fence _ _ •— —7"M [27]� 110"B with mesh size of 1-1/4" 1 60" tall Chain Link Fence �t. 125.00 _ . _ . _ • —� _ 7" �31] O [ 0 ] 0 CIVIL PLAN ■ with mesh size of 1-1/4" \ [32 / 1 6 C Sheet P 1.0 and Pump Specs. — N85009'00"E 5700 _•_._ —'—• \ \ / Y I [T6]0 / ■ 3 Discharge pool footing \ � Lockable Self Closing 13"CHQ ■ ; []drains to 4' x 4 x 4 drywell \ and Latching Gate [33] ■ 1 1 0/ N1 I �"F o 061 C/ I CITY OF EDMONDS BUILDING DEPARTMENT 2021 ■ / I ----T5�------ — PT4) 1 16■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■ I \ / 1-------------- SDCO, TYP 2" PVC w/Electrical Water Bond ---- / _--------------- / _ ---- / (Yp) SDC0, TYP \ _-- --Filter Flow arrows t F_,_ 12 — — — — 1 ---�--------- Pool Pump � — — �-------- / n f _F 16 _ — —Heater �— -- Pentair Intelcenter i / ____________________ �, I II I �� �� I Control Panel "�______- / 1 \ MtN 1 12131415 / I I1 11 - Pool Footing Drain Lines 11 / I / 11� I 1 I ; m 1 Walls And Solid (Perf Pipe nPVC of I i 5 Skimmer - I See civil and architectural site plans I ', I For Conveyance) I\ I 6 1 - I Swimming Pool Plumbing \ Return 7 I ------2" schedule 40 PVC from Building Permit Application i I , I I y \ I I I g Pool Cover Control Swich 11 \ #BLD2023-0700 additional site, / '�. I I 1\ Coverstar Automatic i / 10 / 1 building and unlit information ----'I 20Poolcover y / y [ ] I ; 0 �' ► i /' SDCO, TYP--------� /' sheet 02 & C3.1) I c5 12" area drain with open grate I / ---`-- II Lockable Self Closing 1 i and Latching Gate \ I Return 1 Guards Per 1 Architectural I ; MAIN ENTRY ;� I. 3 I Plans o/ of proposed new single L� 1 family residence per / \ Discharge overflow I F_F—r F—FJ 1 Sanitary Sewer Cleanout with Y p / I 10.6"C _F_F— 1 / #BLD2023-0799 1 _ ._.._.._.�_. _.._.. I Backflow Preventor to 4' x 4' x 4' drywell F_F—"' Catch Basin / / \ O 1 1 I --- Approx. location of hose bib El 3.2 r .e\\_.I................ I -- _ 1 / / \ 1 4 Sanitary Sewer Cleanout with Proposed stormwater infiltration / Sewer Pump Station 1 / trench - see civil site plan from Backflow Preventor #BLD2023-0799 1 —� I I i ' / Lockable Self Closing �I �1 1 `o I 14.6"M I s oX and Latching Gate I I I " 1 /[10] � / / I [, 1 I rSanitarySewer 60" tall Chain Link Fence [7]O 11"C anout I �s I N with mesh size of 1-1/4" / I Sanitary Sewer / [6] 9.1" F R �' ' / �5' Cleanout / 22.2"C — [51 �_/ _ . _ • — — — . _ • / 9QC 60" tall Chain Link Fence 1 T9 J s \ _ _ [ ] L with mesh size of 1-1/4"\ / 2 / �� Sanitar Sewer 0 ' I \ Y o I [ 1 N85°09'00_'E_182.00 / Cleanout — _ [�1 . �— — ' — — I DECIDUOUS / \ / _ _ _ . _ • 7 / 0 1011C 1 I / CLUMP / 1TD O 1 — \ \ �'/ I �2UD O `17 [g1 MAPLE LUSTER I /' _ _ . _ • — — — 60" tall Chain Link Fencel 3�� o I � 1 1 — 11C® with mesh size of 1-1/4" I [S] ��] 5? - OCf) / 1 18] I1 [Q1 S2� \ 8'MH MAPLE f 1[11] 1 I [ 1 CLUSTER O W 30"FIR /' \ I \ \ I I [V] i \ I. I W i — — In W .— S-S\ SS I) , I� / 0 � u POOL SITE PLAN SCALE:1" =10' 0 See Building Permit application #BLD2023-0799 for details on proposed single-family residence on site 20.5"M [14] 6"M [T2] 2 ElGrade pool deck to flow towards 12" area drain as indicated by flow arrows. Pool shall be drained via mobile electric pump. Pool water discharged into sanitary sewer cleanout located within 50' of pool. No direct plumbing connection between pool and sewer. ❑3 See sheet C3.1 permit re -submittal. Add 12" area drain with open grate. ® The pool will be filled by hose bib located within 30-50' of pool. ❑5 The pool will not be heated above 90 degrees © The base of the pool will be compacted sand and gravel ❑7 Fiberglass pool will comply with standard: IAPMO Z124.7 ElCoverstar pool cover is complaint w/ASTM F1346. See Attached re -submittal PDF documents Thursday Pools are complaint w/IAPMO Z124.7. See Attached re -submittal PDF documents 10 Coverstar pool cover control (open/close) switch shall be within sight of pool cover 11 Pool cover drainage vault 4" drain to drain into 4x4x4 drywell 12 Pool Pump - Pentair Inteli-Flow VSF #3 13 Pool Filter - Pentair Clean and Clear 420 Filter 14 Pool heater - Pentair Ultra Temp 120 H/C 15 Pool System Controller - Pentair Intel Center Control Panel. Control of Lights, Temp., Run Schedule, Pump Speed. Compliant with WSEC section R403 and 2018 ISPSC section 303. 16 Hydrologically conjoined. 5' minimum spacing in compliance with Virginia Baker Act. BLD2023-0811 No 1010101010 No REVIEWED BY CITY OF EDMONDS BUILDING DEPARTMENT RESUB Mar 05 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT POOL SITE PLAN 02-01-2024 Pi .0 COCHRAN RESIDENCE PAGE 1 OF 1 THURSOAY-C,-8475 FREDERICK PL DOLS, EDMONDS WA 98026 Your weekend starts early with us Little Bob LX 13.5 x 3. 35'-9" PLEASE SEE GENERAL CONSTRUCTION AND RECOMMENDED INSTALLATION NOTES *All depths reflect the depth of the pool structure. Water depths may vary depending on the amount of water in the pool. Depth: 41,611 i Slope = 0% General Tolerance +/- 1/2" This NOTICE AND DISCLAIMER is made to all retail customers, buyers, and end users of pools manufactured by Thursday Pools. You are by this NOTICE advised that pools manufactured by Thursday Pools (the "MANUFACTURER") are sold by independent dealers and dealerships. Each dealer is an independent businessperson who is completely separate from the MANUFACTURER. Each dealer is an independent contractor, and no dealer is an owner, agent (in fact or law), or employee of the MANUFACTURER. The MANUFACTURER hereby DISCLAIMS any liability for an intentional or negligent act by any dealer, dealership, or installer, or any damage to any Thursday Pools pool caused by an act of any dealer, dealership, or installer.