101
® F.E.
Al
n
EXHAUST FAN WITH LIGHT AS CALLED OUT ON PLANS
TRACK FIXTURE, OWNER TO SELECT
PENDENT FIXTURE, OWNER TO SELECT.
RECESSED CAN LIGHTING WITH TRIM RINGS.
SURFACE MOUNTED LIGHT FIXTURES, OWNER TO SELECT
WALL MOUNTED LIGHT FIXTURE, OWNER TO SELECT.
GARBAGE DISPOSAL
GFI DUPLEX RECEPTACLE
DUPLEX RECEPTACLE
GFI DUPLEX RECEPTACLE WI WEATHER PROOF COVER
TELEPHONE JACK (12" AFF UNLESS OTHERWISE NOTED.)
SINGLE POLE LIGHT SWITCH
3 WAY SINGLE POLE LIGHT SWITCH.
SMOKE DETECTOR
HOSE BIB WITH FROST PROTECTION
TOP OF PLATE ELEVATION
GRADE ELEVATION
BUILDING SECTION
WALL SECTION
DETAIL
INTERIOR FINISH WALL ELEVATIONS
GRID LINES - COLUMN
ROOM NAME AND NUMBER
FIRE EXTINGUISHER
SEE SPECIFICATIONS
REVISION TAG
DOOR TAG
ILLUMINATED EXIT SIGN
ARROW INDICATES DIRECTION
ILLUMINATED EXIT SIGN WITH EGRESS
PATH LIGHTING WITH BATTERY BACKUP SYSTEM
EGRESS PATH LIGHTING ON BATTERY
BACKUP SYSTEM
WALL SCHEDULE
EXISTING WALLS TO REMAIN
EXISTING WALLS TO BE REMOVED
NEW 2X6 WALL @ 16" OC W/ 1/2" GWB AT OUTSIDE OF BATHROOM AND 1/2" M.R.
GWB ON THE INTERIOR, FILL STUD SPACE WITH SOUND BATT INSULATION, TYP.
NEW 2X4 WALL @ 16" OC W/ 1/2" GWB AT OUTSIDE OF BATHROOM AND 1/2" M.R.
GWB ON THE INTERIOR, FILL STUD SPACE WITH SOUND BATT INSULATION, TYP.
ALL WORK SUBJECT
TO FIELD
INSPECTION FOR
CODE COMPLIANCE
APPROVED
PLANS MUST BE
ON JOB SITE
City
Of Edmonds
Building Department
Work
REMODEL
Address
734 FIR ST
Owner
KLEVEN
Approved Date
Building Official
1_11 /18/2 24
wm'��4 �'
Permit Number
BLD2024-1514
0
0
N
EXISTING SECOND FLOOR PLAN
SCALE: 1/4" =1' - 0"
52'-0"
14'-0" 24'-0"
DECK
0
MSTR. BEDROOM
OPEN TO BELOW
14'-0"
DECK
BEDROOM
ROOF
EXIST. SD
•
EXIST. SD
CLOSET O CLOSET CLOSET
DN EXIST. SD
• EXIST. SD
MIN. VERIF 2X6 STUD WALL AT 16" OC,
3s MiN CLEAR WITH SOUND BATT INSUL.
710
2X4 STU WA L " 0 ,
SOUND AT IN UL.,TY BEDROOM
BATHROOM 2'-4" X 6'-8" SC POCKET DOOR, _ PR -FAB SHOWER PAN
O MATCH STYLE AND FINISH
CLOSET WITH BEDROOM DOORS, TYP.
O • • WATERPROOF CAN LIGHT FIXTURE
EXIST. SD CO N 50 CFM (MIN) EXHAUST FAN WITH
O HALL 1($GFCI W TERPROOF LIGHT FIXTURE
VERIFY EXISTINGCARBON MONOXIDE ALARM,
PROVIDE AN ALARM IN THE MAIN LEVEL, IN HALL
OUTSIDE OF BEDROOMS, AND IN THE BASEMENT.
13
_.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._.._ A 1..�..�..�..�..�..�..�..�..�..�..�..�..�..�..�..�..�..�..�..�:
1 1
WHERE ADDITIONS OR ALTERATIONS REQUIRE A PERMIT 1 1 STRUCTURAL REPAIR IS NOT INCLUDED IN THE SCOPE FOR THIS PERMIT.
IF IT IS FOUND THAT STRUCTURAL REPAIRS ARE NEEDED A SEPARATE 1
TO BE ISSUED INTERCONNECTED SMOKE ALARM AND CO 1 1 PERMIT MUST BE SUBMITTED TO THE CITY FOR APPROVAL, AND PLANS
1 DETECTORS THROUGHOUT THE DWELLING IS REQUIRED. MUST BE STAMPED AND SIGNED BY THE ENGINEER OF RECORD. 1 ❑
i 1 1
REFER TO 2021 IRC R314 AND R315 FOR MORE 1
INFORMATION.
1 ;
�..�..�..�..�..�..�..�..�..�..� LIMIT OF WORK
NORTH SECOND FLOOR PLAN THIS PERMIT
SCALE: 1/4" = 1' - 0"
EXISTING WINDOW VERIFY IF TEMPERED GL
24" SINK BASE AND 24" DRAWER CABINET,
7'-5%" FIELD VERIFY CLEARANCE AND WALL ANGLE
VERIFY VANITY LIGHT FIXT.
❑ ❑ ROOF ❑ ❑ WITH OWNER ❑ ❑
PROJECT SCOPE
CONSTRUCTION OF A NEW SECOND FLOOR BATHROOM (44 SF) WITHIN AN EXISTING
SINGLE FAMILY RESIDENCE. THERE IS NO EXTERIOR WORK OR WORK ON OTHER
FLOORS OR AREAS AS PART OF THIS BUILDING PERMIT SUBMITTAL.
LEGAL DESCRIPTION
(PER DEED OF TRUST RECORDING #202109220922)
LOT 10, BLOCK 10, YOST'S FIRST ADDITION TO EDMONDS, ACCORDING
TO THE PLAT THEREOF RECORDED IN VOLUME 8 OF PLATS, PAGE 6,
RECORDS OF THE AUDITOR OF THE COUNTY OF SNOHOMISH, STATE
OF WASHINGTON;
EXCEPT THE WEST 75 FEET THEREOF.
SITUATE IN THE COUNTY OF SNOHOMISH, STATE OF WASHINGTON.
SITE & BUILDING INFO.
OWNERS KLEVEN RESIDENCE
734 FIR STREET
EDMONDS, WA 98020
TAX PARCEL NUMBER -
PROJECT ADDRESS -
GOVERNING BUILDING CODE -
GOVERNING ZONING CODE -
RELATED BLDG. PERMIT -
AREA OF NEW WORK:
SITE STATISTICS
ZONE -
SITE AREA -
HOUSE FOOTPRINT -
LOT COVERAGE -
00619401001001
734 FIR STREET
EDMONDS, WA 98020
2021
204&INTERNATIONAL RESIDENTIAL BUILDING CODE W/
WA STATE AMENEDMENTS
CITY OF EDMONDS LAND USE CODE
#BLD2023-0098
ISSUED 09/13/2023
44 SF (ENTIRELY WITHIN THE EXISTING BUILDING)
RS-6 ZONING AREA
5,976 SF +/- (0.14 ACRES)
1,372 SF (NO CHANGE)
23% (NO CHANGE)
DEFFERED SUBMITTALS
ELECTRICAL
MECHANICAL
PLUMBING
DESIGN BUILD BY ELECTRICAL CONTRACTOR
DESIGN BUILD BY MECHANICAL CONTRACTOR
DESIGN BUILD BY PLUMBING CONTRACTOR
GENERAL NOTES
1. THE APPROVED PLANS SHALL NOT BE CHANGED OR ALTERED WITHOUT AUTHORIZATION FROM THE
CITY OF EDMONDS BUILDING OFFICIAL. THE APPROVED PLANS ARE REQUIRED TO BE ON THE JOB SITE.
2. CONTRACTOR SHALL VERIFY AND CHECK ALL CONDITIONS & DIMENSIONS AT THE BUILDING. REPORT
ANY INCONSISTENCIES TO THE ARCHITECT.
3. CONTRACTOR DESIGNED ELECTRICAL, SUBMIT FOR ELECTRICAL PERMIT AS REQUIRED BY STATE AND
CITY OF EDMONDS.
4. CONTRACTOR DESIGNED HVAC, EXHAUST FAN TO VENT TO EXTERIOR. PROVIDE WEATHER FLAP AND
INSECT SCREENING WHERE VENT TERMINATES AT EXTERIOR WALL.
5. ALL OPENINGS TO BE CAULKED, SEALED OR WEATHER STRIPPED.
6. PROVIDE METAL NAIL STOPPER PLATES TO COVER HOLES IN STUDS WHERE NAILS COULD PUNCTURE
PLUMBING OR ELECTRICAL WIRING.
7. ALL WOOD COMING IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED (DECAY RESISTANT).
8. ELECTRIC RADIANT FLOOR HEAT TO BE INSTALLED IN BATHROOM FLOOR. PROVIDE DEDICATED
BREAKER FOR FLOOR HEAT SYSTEM AS MANUF. BY DITRA
9. TEMPERED GLASS REQUIRED IN ALL SHOWER DOORS AND PANELS. VERIFY EXISTING WINDOW IN
SHOWER IS TEMPERED.
10. BATHROOM EXHAUST SHALL BE VENTED TO THE OUTSIDE UNLESS OTHERWISE APPROVED BY THE
BUILDING OFFICIAL. PROVIDE EXHAUST AT A RATE OF 50 C.F.M. INTERMITTENT OR 25 C.F.M.
CONTINUOUS (MIN.) IN BATHROOMS AND LAUNDRY ROOMS.
11. VERIFY EXISTING SMOKE DETECTORS ARE FUNCTIONAL. SMOKE DETECTORS TO BE LOCATED IN EACH
BEDROOM AND IN HALLS WITH CLOSE PROXIMITY TO BEDROOMS, AND ON EACH STORY. WHERE GWB
HAS BEEN REMOVED NEW SMOKE DETECTORS SHALL BE POWERED BY 110V. AC WITH BATTERY BACKUP
AND INTERCONNECTED ON ALL FLOORS.
12. PROVIDE CARBON MONOXIDE ALARM OUTSIDE EACH SLEEPING AREA AND ON EACH LEVEL OF
DWELLING PER CURRENT CODE. APPLIES TO BOTH NEW AND EXISTING DWELLING UNITS.
13. ALL GWB INSIDE BATHROOM TO BE PRIMED 1/2" MOISTURE RESISTANT TYPE. GWB TEXTURE TO MATCH
EXISTING GWB FINISH, TYP. VERIFY PAINT FINISH WITH OWNER. REMOVE EXISTING CEILING GWB IN
BATHROOM AND PROVIDE ADDITIONAL FRAMING AS REQUIRED FOR M.R. GWB CEILINGS.
14. PROVIDE SINGLE WAND SHOWER VALVE, STYLE AND FINISH PER OWNER.
15. TOILET TO HAVE BIDET FUNCTION.
16. THESE DRAWINGS HAVE BEEN PREPARED FOR A 24" X 36" PROJECT SHEET.
17. GOVERNING BUILDING CODE: 2018 INTERNATIONAL RESIDENTIAL BUILDING CODE PUBLISHED BY THE
INTERNATIONAL CODE COUNCIL, AS ADOPTED BY THE WASHINGTON STATE BUILDING CODE COUNCIL IN
CHAPTER 51-51 WAC.
2021
18. 20+8 WASHINGTON STATE ENERGY CODE
Q
O
D-
w
D_
Q
cn
z
_
w
g
O
-
z
w
w
U
w
w
D_
O
CD
01�
D_
0o
z
Li-0
z
O
U
U
LLJm
w
z_
Q
Q
Q
U")
o
w
w
o
��
cn
0
o
z
M
0
0
0
0 0
D
O
m
>
U!
o
J
z
0)
>
0)
>
0)
>
0) M
> >
�
a-
D
(n
w
D_
w
D_
D
m
O
U
w
D_
w
D_
w
D_
w w
D_ D_
N
N
N
CD
N
O
O
N
O
DO
Do
o
This space reserved for:
CITY OF EDMONDS
DEVELOPMENT SERVICES DEPARTMENT
w
02
ZO
W
=
o
N
m
w
00
W�
�
o�
��
a
LL
[z
z
LU
�O
�o
zJ
wz
U)
w
>
w
w
Jz
RECEIVED
Nov 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
DRAWN
BK
CHECKED
BAK
DATE
11 /18/2024
SCALE
AS NOTED
■
1 ❑ 1 ■ SHEET NUMBER
Cu TAIN ELECTRICAL OBTAIN A SEPARATE
PERMIT FROM PLUMBING PERMIT
STATE LABOR & FROM THE CITY OF 1 ■
52R
•. INDUSTRIES EDMONDS.
1 1 1 FILE: KLEVEN RESIDENCE PLAN
1
■ 1'
1.■.■■.■.■■.■.■■.■.■■.■.■■.■.■■.■.■■.■.■�1�■■■■■■�■�■■�■�■■�■�■■�■�■■�■�■■�■�■
BATHROOM PLAN
OPTION 3
9/27124