Loading...
APPROVED PLN ENG RESUB 1-BLD2024-1385+Site_Plan+11.27.2024_12.44.37_PM+4643544All disturbed areas to be compost amended per 2019 SWMMWW BMP T.5.13. Install and maintain all TESC measures according to approved plans, City of Edmonds standard details, and all other measures that may be required during construction OWNER/CONTRACTOR IS RESPONSIBLE FOR EROSION CONTROL AND DRAINAGE ACCEPTABLE TIGHTLINE MATERIAL: SDR 35 SCH 40 N-12 F810 HANCOR Zone IRS-12 1 Corners Flag ,_ Setbacks: Required Actual Front 25' ------ 51' - -10, - 14'-& Sides 1�' (W� 25' 50' Rear Other - - - - - 25' 13'-8' Height Nothing in the permit approval pro( interpreted as allowing or permitting the maintenance of any currently existing illegal, nonconforming or unpermitted building, structure or site condition which is outside the scope of the permit application, regardless of whether such building, structure or condition is shown on the site plan or drawing. Such building, structure or condition may be the subject of a separate enforcement action. Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per city standards that is caused or occurs during the permitted project. No — APPROVED BY PLANNING Ca,,MA/V^S,-,� Dec 10 2024 LOT COVERAGE CALCULATIONS: TOTAL LOT AREA = 13,939 SQ.FT. EXISTING HOUSE = 2,181 SQ.FT EXISTING SHED = 176 SQ.FT PROPOSED STRUCTURES = 536 SQ.FT TOTAL LOT COVERAGE: SQ.FT.= 2,893 = 20.75% IMPERVIOUS AREA CALCULATIONS: EXISTING STRUCTURES = 2,357 SQ.FT PROPOSED STRUCTURES = 536 SQ.FT EXISTING DRIVEWAY, SIDEWALK & PATIO = 4,325 SQ.FT TOTAL LOT AREA = 13,939 SQ.FT. TOTAL IMPERVIOUS AREA = 7,218 SQ.FT = 51.78% TOTAL FLOOR AREA = 2,893 SQ.FT FLOOR AREA RATIO (FAR):20.75% • NEW INTERNAL GUTTERS WILL BE TIED BACK INTO EXISTING RAIN GUTTERS THAT ARE ALREADY INSTALLED ON THE HOUSE. NO NEW DISCHARGE WILL BE CREATED. CURRENT GUTTERS DISCHARGE INTO DRY ROCK DRAINAGE SYSTEM. AND SHALL NOT NEGATIVELY IMPACT NEIGHBORING PROPERTIES, CITY INFRASTRUCTURE, SLOPES, ETC. • ALL WORK IS GOING ON EXISTING DECK. NO WATER OR SEWER UTILITIES WILL BE DISTURBED. • NEW STRUCTURES WILL BE THE SAME HEIGHT AS THE EXISTING ROOF. ENGINEERING DIVISION APPROVED AS NOTED 12/10/2024 ***NO LAND DISTURBANCE PROPOSED. *** NO STORMWATER MANAGEMENT SYSTEM REQUIRED AT THIS TIME. IF NEW AND/OR REPLACED IMPERVIOUS SURFACE EQUALS 2000SQFT OR GREATER, A STORMWATER MANAGMEMENT SYSTEM MAY BE REQUIRED PER CITY CODES AND STANDARDS BLD2024-1385 *NOTE: FOR THE SCALE TO BE CORRECT SHEET MUST BE PRINTED ON 11" x 17"* RESUB Nov 27 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT NOTES: X = EXISTING RAIN GUTTER 1 SITE PLAN ADDRESS: 790 NORTHSTREAM LN EDMONDS, WA 98020 PARCEL ID: 00532500001400 LOT AREA: 0.32 ACRES PLOT SIZE: 11" X 17" DRAWING SCALE: 1"=30'