APPROVED ENG PLN RESUB 3-BLD2023-1355+Site_Plan+10.18.2024_3.31.39_PM+4569296Mi
0
0
J
J
U)
w
z
O
J
a
0
z
a)
U)
U
O
0
0
c
0
L
a�
Y
7
L.L
^o
� J
E;
c
a)
0 iL
�U)
0
� c
a)
�:'U)
Q E
N
M
J --1)
>1>1
mm
27-
M 15�
CO CV
C0N N
00
C9 0
ai
2
a�
o>
o= C` )
ROPERTY CORNER —/
416.85 I funi
�
/
/ o
7.50,
BSBL '
MAIN FLOOR ELEVATION (M FE)
BOTTOM OF EXCAVATION
FRONT GARAGE ELEVATION
APPROVED BY PLANNING
Nov 19 2024
Zone RS-g
Corner
Flag —
Setbacks:
Required
Actual
Front
25'
25'
Sides
7.5'/7.5'
17'3"/7'6"
Rear
15'
54'
Other
25'
24.66'
Height
E AT PROPERTY CORNER
416.27
_ SS SS
A PORTION OF THE NW 1/4, SECTION 19, TOWNSHIP 27 NORTH, RANGE 4 EAST, W.M.
N89°04'20"E 80.00' � ti
m
m
III
D
417.10 C� -------------
413.60
416.67
I I I
I
_ I
I
0) I — — — — I
00 ------J
I I o
LU I I 00
o I I
N
o
i PROPOSED NEW SINGLE i o
FAMILY HOUSE I N
Z I I ch
I I °
I I z
I I
I � I
I � I
r—— — — — — — - --�
d ° dA. .d V I I
° d d
. . . . . . . . . . . . . i . A. . •° a . a d. I I
.......... a °.
d d. .Q
. , d' ° d d d
. . . . . . . . . . . . . .I d. ' °
d °
. . . . . . . . . . .I aad.... dd.° : ° �. I
° d d d / I
20.00
FLOd
W PATH I de d a a °. a
° d
. . . . . . . . . .I °' n .:
° .. d: .d d
—
d d. .. .4'
d
I : ' L--------------
d d °
. . d d d O
d
• d . G
° d I r - — — — — — — — — —
. W :.......
y ° d °dI ' . d' a daO U. . . . .
ohm
a
i I I I j
New.
Ln d
. . . . . . . . . . d .... . Q. I `---------I I
I °
d d d L---------r-_ _- --I . d
d dd C .
' d
I
/ 10' ROW DEDICATION
I
IA
I 417
N89004'20"E 99.25' � -�
W W W I W
O
b / _
oU o
SS SS yls SS SAS ^ SS SS SS SS SS SS SS SS
'X
0
� I
ENGINEERING DIVISION
APPROVED AS NOTED
11 /27/2024
NORTH SEE APPROVED CIVILS FOR ALL
10 0 5 10 20 ENGINEERING REQUIREMENTS.
I (FEET)
I 4-1
/ HOUSE HEIGHT CALCULATIONS
d . a 4 HOUSE RECTANGLE EXISITNG CORNER ELEVATIONS
0a POI NT A 416.78
POINT B 416.40
POI NT C 415.23
POINT D 415.99
0 / AVERAGE EXISTING GRADE 416.10
MAXIMUM ROOF HEIGHT 441.10
/ VERTICAL FEET BETWEEN
MAX AND PROPOSED 000.34
7 SO' 4 HEIGHT SURVEY REQUIRED AS LESS THAN 1 FOOT DIFFERENCE
BS L Proposed Height = 440.76
/ MAIN FLOOR ELEVATION 417.10
a FRONT GARAGE ELEVATION 416.67
I Datum (See Civil Plan) = 416.53
4
a�
44
\ d 4
d
TYPEOFAREA
AREA (S:)
ST0R0\ATER FAG UTY
LAWN AND LANDSCAPE
9,938
P TANK DETENTION
ROOFS
3,259
P TANKDETENTION
DRIVEWAY
1, 516
BMP T5.12 SHEET FLOW
DRIVEWAY
293
JPTANKDETENTION
°/oF E F1T
3,423
1 F;F=VIOVAL
SINGLE FAMILY RESIDENTAL SETBACKS
STREET SETBACK 25
4 \ SIDE SETBACK 7.5'
1 4 \ REAR SETBACK 15'
I MAX. HEIGHT 25'
m MAX. LOT COVERAGE 35%
\ \ aa a��
IMPERVIOUS CALCULATIONS
LOT AREA=15,056 SF
I/ HOUSE = 2,974 SF
V oy II LOT COVERAGE = 19.8%
ROOF AREA = 3,259 SF
DRIVEWAY/WALKWAY/PATIO=1,900SF
TOTAL = 5,159 SF
o� IMPERVIOUS = 34.1%
DRIVEWAY BM T5.12 SHEET FLOW = 1,516 SF
�o DRIVEWAY LOCATED WITHIN ROW = 310 SF
(TO BE DRAINED TOWARDYD#1)
o
REMAINING IMPERVIOUS FOR DETENTION = 3,615 SF
° I R-TANK VOLUME REQUIRED = 72.3 SF X 3' DEPTH
= 216.9 C F
R-TANK DETENTION PROVIDED = 3.08 SF X 25 MODULES X 3' DEPTH
X 95 % POROSITY
\ - 219.3 CF
MAX. ALLOWED IMPERVIOUS = 5,166 SF
\ I 7
O
I o=
PRIVATE DRAINAGE EASEMENT PER o
KING COUNTY RECORDING NO. 202410090252 �oy� U)
` N89°04'20"E 78.39' O
-A yo
0
U)
� Oy G�
LL
200TH ST SW_
BLD2023 1355
APPROVED FOR CONSTRUCTION
oya o `" o CITY OF EDMONDS
— SS SS \S SS SS SS SS SS SS SS SS SS DATE:
BY:
\ I I CITY ENGINEERING DIVISON
U U 0
m J J
J �
z
O
w
z
z
�
w
w
a
o
0
0
O
U)
U
U
w
~
~
z
0�
U
U
O
g
O
U
Q
Q
CV
N
CV
w
I.-Lo
N
0
Q
-
CV
M
O
�q
0
0
V
CV
CY)
RESUB
Oct 18 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
PERMIT
Z
a
U
W
3
Z
Z
(A
C)
��
VI
w
L
J
W
W
Z
�
o
J
Q�
O
0
N
LL
J
J
J
M
O
W
>
a
00
z
s!
s
MOMENTUM CIVIL
1145 BROADWAY, SUITE 115
TACOMA, WA 98402
PHONE: 253.319.1504
CHECKED BY: D. HARRIS
DESIGNED BY: D.HARRIS
DRAWN BY: J.SANTOS
HORZ. DATUM:NAV83/91
VERT. DATUM: SSHM ON 201
DATE: 10/16/24
PROJECT NO. VILL-001
SHEET NO. 1 OF 1
REFERENCE NO. Sl