BLD2024-1641_Manufacturer_Specifications_and_Installation_Instructions_12.16.2024_3.47.12_PM_46726326269412-YTG-A-0922 42YORK0 Technical Guide Variable Speed ECM Modular Multi -Position Air Handlers For use with split -system cooling and heat pumps Models: JMVT Series " GOOD-N��"� /HOUSEKEEPING\ 9000 REGIS'CRA���y ISO 9001 Certified Quality Management System cicp u$ Due to continuous product improvement, specifications are subject to change without notice. Visit us on the web at www.simDivaettinatheiobdone.com and www.york.com Additional rating information can be found at www.ahridirectory.org WARRANTY SUMMARY Standard 5-year limited parts warranty. Extended 10-year limited parts warranty when product is registered online within 90 days of purchase for replacement or closing for new home construction. Description This unique modular system provides the flexibility to handle any application. These versatile JMVT blowers can be used for upflow, downflow, or horizontal left, or right applications. They can be combined with cased coils to function as a cooling only unit or with a heat pump including electric heat for 208-230-1 and 208-230-3 phase applications. The JMVT blower and 8HK electric heater kits can be used as stand alone electric furnaces. Features Next generation high -efficiency blower - delivers increased airflow and reduced blower watts by 10%, using a variable speed ECM motor Variable speed operation - provides flexibility in application as well as upgraded system efficiency Next generation insulation and gasket design - reduces thermal transmission paths and reduces sweating Electric heat kit - 8HK field -installed series available for easy installation and service application Designed for easy installation and service - casing size of 20.5 in., smooth sides, and rigid construction provide ease of attic access and tight applications. Front facing components, slide out blower, laser cut knock outs, and integrated duct flanges shorten install time. Cabinet air leakage - less than 2% at 1 in. W.C. external static pressure when tested in accordance with ASHRAE Standard 193 Long lasting quality - structural components made of post - powder painted aluminum or galvanized steel to prevent corrosion FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 6269412-YTG-A-0922 List of sections Nomenclature Description............................................1 Features..............................................1 Nomenclature..........................................2 Dimensions and duct connections ......................... 3 Technical data.........................................3 Power wiring..........................................11 Accessories..........................................11 Limitations...........................................12 Typical applications .................................... 13 Control wiring.........................................13 Airflow data...........................................14 Brand J J = JCI air handler Type M M = modular blower Motor type V V = multi variable speed ECM E = multi standard ECM P = multi PSC Stage T S = single stage capable T = two stage capable V = variable stage capable Cabinet width (in.) B A = 14.5 C = 21 B=17.5 D=24.5 Options - C = communications ready - (no designator) = standard (no options) Nominal airflow 12 08 = 800 CFM 12 = 1,200 CFM 14 = 1,400 CFM 16 = 1,600 CFM 20 = 2,000 CFM Voltage (voltage -phase -hertz) 2 2 = 208/230-1-60 Generation (major revision) 1 1 = first generation 2 = second generation Style letter (minor revision) not used for ordering A A = style A B = style B Johnson Controls Ducted Systems Dimensions and duct connections 6269412-YTG-A-0922 if Figure 1: Duct connections Table 1: Dimensions Top outlet dimension Service disconne Bottom inlet dimensions C 19 1/8 in. A1712-001 Models Dimensions Wiring knockouts A B C D E F Height (in.) Width (in.) Opening widths (in.) Power (in.) Control (in.) JMVT12BC2N1 22 3/4 17 1/2 10 1/2 13 1/2 7/8 (1/2) 13/8 (1) 1 23/32 (1 1/4) 7/8(1/2) JMVT16CC2N1 22 3/4 21 13 1/4 16 1/2 JMVT17CC2N1 22 3/4 21 13 1/4 16 1/2 JMVT20DC2N1 22 3/4 24 1/2 14 1/2 20 1. Actual size (conduit size) Technical data Table 2: Cooling capacity' XAF Models Rated CFMZ Entering air dry/wet bulb (°F) MBH at evaporation temperature and corresponding R-410A pressure p (,F/sig)45/130.7 35/107.9 40/118.9 50/143.3 XAFA18A 600 85/72 43.2 38.4 32.9 26.9 80/67 34.8 29.9 24.4 18.9 75/62 27.2 22.4 17.3 11.7 70/57 20.6 15.8 10.7 8.1 XAFB18A 600 85/72 43.2 38.4 32.9 26.9 80/67 34.8 29.9 24.4 18.9 75/62 27.2 22.4 17.3 11.7 70/57 20.6 15.8 10.7 8.1 Johnson Controls Ducted Systems 3 6269412-YTG-A-0922 Table 2: Cooling capacity' XAF (continued) Models Rated CFMZ Entering air dry/wet bulb (°F) MBH at evaporation temperature and corresponding R-410A pressure (oF/sig) p 35/107.9 40/118.9 45/130.7 50/143.3 XAFA24B 800 85/72 54.8 49.2 43 35.8 80/67 44.7 39 32.3 25.2 75/62 35.4 29.5 23 15.5 70/57 27 20.9 14.2 10.9 XAFB24B 800 85/72 54.8 49.2 43 35.8 80/67 44.7 39 32.3 25.2 75/62 35.4 29.5 23 15.5 70/57 27 20.9 14.2 10.9 XAFB30C 1000 85/72 62.3 56.9 49.8 42.3 80/67 51.9 45.7 38.4 30.5 75/62 41.7 34.6 27.9 18.4 70/57 32.1 25.3 18 13.9 XAFC30C 1000 85/72 62.3 56.9 49.8 42.3 80/67 51.9 45.7 38.4 30.5 75/62 41.7 34.6 27.9 18.4 70/57 32.1 25.3 18 13.9 XAFA30D 1000 85/72 72 64.5 55.8 46.1 80/67 58.6 50.8 42 32.4 75/62 45.9 38.5 29.8 19.8 70/57 35 27.6 19.1 14.5 XAFB36D 1200 85/72 80.2 72.1 62.8 52 80/67 65.5 57.2 47.4 36.5 75/62 52 43.5 33.4 22.2 70/57 39.9 30.9 22.1 16.8 XAFC36D 1200 85/72 80.2 72.1 62.8 52 80/67 65.5 57.2 47.4 36.5 75/62 52 43.5 33.4 22.2 70/57 39.9 30.9 22.1 16.8 XAFB36E 1200 85/72 73.6 67.5 60.5 52 80/67 61.6 55 47.2 38.2 75/62 50.3 43.1 34.9 23.8 70/57 39.5 31.7 23.4 18.2 XAFC42E 1400 85/72 78.3 72.1 64.7 56 80/67 65.7 59 50.9 41.4 75/62 53.8 46.4 37.8 26.4 70/57 42.5 34 26 20.3 XAFD42E 1400 85/72 78.3 72.1 64.7 56 80/67 65.7 59 50.9 41.4 75/62 53.8 46.4 37.8 26.4 70/57 42.5 34 26 20.3 XAFC48F 1600 85/72 95.6 87.2 77.7 66.3 80/67 79.5 70.6 60.5 48.4 75/62 64.5 54.9 44.2 29.6 70/57 50.2 40.1 29.4 22.9 Johnson Controls Ducted Systems 6269412-YTG-A-0922 Table 2: Cooling capacity' XAF (continued) Models Rated CFM2 Entering air dry/wet bulb ff) MBH at evaporation temperature and corresponding R-410A pressure p (oF/si9)45/130.7 35/107.9 40/118.9 50/143.3 XAFD48F 1600 85/72 95.6 87.2 77.7 66.3 80/67 79.5 70.6 60.5 48.4 75/62 64.5 54.9 44.2 29.6 70/57 50.2 40.1 29.4 22.9 XAFC60G 1600 85/72 102.4 91.9 79.8 66.3 80/67 83.7 72.6 60.3 47.3 75/62 66.4 54.9 43.1 29 70/57 50.5 39.3 27.5 20.7 XAFD60G 1800 85/72 109.1 98.2 85.3 71 80/67 89 77.6 64.7 50.6 75/62 71.1 58.9 46.2 30.4 70/57 54.1 42.2 29.8 22.5 XAFC60H 1800 85/72 107 97.1 85.4 72.2 80/67 88.2 77.8 65 51.9 75/62 70.9 59.4 47.1 31.8 70/57 54.5 43.1 30.6 23.4 XAFD60H 1800 85/72 107 97.1 85.4 72.2 80/67 88.2 77.8 65 51.9 75/62 70.9 59.4 47.1 31.8 70/57 54.5 43.1 30.6 23.4 XAFD60J 1800 85/72 112.1 101.6 89.2 75.4 80/67 92.5 88.1 68.5 54.6 75/62 74.2 62.3 49.7 33.6 70/57 57.1 45.7 32.5 24.8 1. Actual capacity varies with the outdoor AC or HP that is used with the system. 2. Airflow is calculated for each system tonnage. Table 3: Cooling capacity' XAH Models Rated CFM2 Entering air dry/wet bulb (°F) MBH at evaporation temperature and corresponding R-410A pressure (,F/sig) p 35/107.9 40/118.9 45/130.7 50/143.3 XAHA18A 600 85/72 43.2 38.4 32.9 26.9 80/67 34.8 29.9 24.4 18.9 75/62 27.2 2.4 17.3 11.7 70/57 20.6 15.8 10.7 8.1 XAHA24B 800 85/72 54.8 49.2 43 35.8 80/67 44.7 39 32.3 25.2 75/62 35.4 29.5 23 15.5 70/57 27 20.9 14.2 10.9 XAHB24B 800 85/72 54.8 49.2 43 35.8 80/67 44.7 39 32.3 25.2 75/62 35.4 29.5 23 15.5 70/57 27 20.9 14.2 10.9 XAHB30C 1000 85/72 62.3 56.9 49.8 42.3 80/67 51.9 45.7 38.4 30.5 75/62 41.7 34.6 27.9 18.4 70/57 32.1 25.3 18 13.9 Johnson Controls Ducted Systems 6269412-YTG-A-0922 Table 3: Cooling capacity' XAH (continued) Models Rated CFMz Entering air dry/wet bulb (°F) MBH at evaporation temperature and corresponding R-410A pressure (°F/prig) 35/107.9 40/118.9 45/130.7 50/143.3 XAHC30C 1000 85/72 62.3 56.9 49.8 42.3 80/67 51.9 45.7 38.4 30.5 75/62 41.7 34.6 27.9 18.4 70/57 32.1 25.3 18 13.9 XAHB36D 1200 85/72 80.2 72.1 62.8 52 80/67 65.5 57.2 47.4 36.5 75/62 52 43.5 33.4 22.2 70/57 39.9 30.9 22.1 16.8 XAHC36D 1200 85/72 80.2 72.1 62.8 52 80/67 65.5 57.2 47.4 36.5 75/62 52 43.5 33.4 22.2 70/57 39.9 30.9 22.1 16.8 XAHC42E 1400 85/72 78.3 72.1 64.7 56 80/67 65.7 59 50.9 41.4 75/62 53.8 46.4 37.8 26.4 70/57 42.5 34 26 20.3 XAHD42E 1400 85/72 78.3 72.1 64.7 56 80/67 65.7 59 50.9 41.4 75/62 53.8 46.4 37.8 26.4 70/57 42.5 34 26 20.3 XAHC48F 1600 85/72 95.6 87.2 77.7 66.3 80/67 79.5 70.6 60.5 48.4 75/62 64.5 54.9 44.2 29.6 70/57 50.2 40.1 29.4 22.9 XAHD48F 1600 85/72 95.6 87.2 77.7 66.3 80/67 79.5 70.6 60.5 48.4 75/62 64.5 54.9 44.2 29.6 70/57 50.2 40.1 29.4 22.9 XAHC60G 1800 85/72 102.4 91.9 79.8 66.3 80/67 83.7 72.6 60.3 47.3 75/62 66.4 54.9 43.1 29 70/57 50.5 39.3 27.5 20.7 XAHD60G 1800 85/72 109.1 98.2 85.3 71 80/67 89 77.6 64.7 50.6 75/62 71.1 58.9 46.2 30.4 70/57 54.1 42.2 29.8 22.5 XAHC60H 1800 85/72 107 97.1 85.4 72.2 80/67 88.2 77.8 65 51.9 75/62 70.9 59.4 47.1 31.8 70/57 54.5 43.1 30.6 23.4 XAHD60H 1800 85/72 107 97.1 85.4 72.2 80/67 88.2 77.8 65 51.9 75/62 70.9 59.4 47.1 31.8 70/57 54.5 43.1 30.6 23.4 XAHD60J 1800 85/72 112.1 101.6 89.2 75.4 80/67 92.5 88.1 68.5 54.6 75/62 74.2 62.3 49.7 33.6 70/57 57.1 45.7 32.5 24.8 1. Actual capacity varies with the outdoor AC or HP that is used with the system. 2. Airflow is calculated for each system tonnage. Johnson Controls Ducted Systems 6269412-YTG-A-0922 Table 4: Physical and electrical data - cooling only Models JMVT12B JMVT16C JMVT17C JMVT20D Blower- diameter x width (in.) 11 x 8 11 x 10 11 x 10 11 x 11 Motor HP 1/2 HP 3/4 HP 1 HP 1 HP Nominal RPM 1050 1050 1050 1050 Voltage 208/230 208/230 208/230 208/230 Full load amps at 230 V 3.8 5.4 7.0 7.0 Type Disposable or cleanable Filterl Size (in.) 16 x 20 x 1 20 x 20 x 1 20 x 20 x 1 23 x 20 x 1 Bottom rack kit 1 BRO1117 1 BRO1121 1 BRO1121 1 BRO1124 Shipping/operating weight (lb) 57/56 63/62 66/65 70/69 1. Field -supplied Table 5: Electrical data - cooling only Models Motor FLA1 Minimum circuit ampacity (A) M0P2 JMVT12B 3.8 4.8 15 JMVT16C 5.4 6.8 15 JMVT17C/JMVT20D 7.0 8.8 15 1. FLA = Full Load Amps 2. MOP (Maximum Overcurrent Protection) device - must be HACR type circuit breaker or time delay fuse. Refer to the latest edition of the National Electric Code or in Canada the Canadian Electrical Code and local codes to determine correct wire sizing. Table 6: Electrical heat: minimum fan CFM dip switch settings for single-phase heat kits Heater kit modelsl,2 Nominal at kW V Air handler models 12B 16C 17C 20D Indoor coil product match XAF XAH XAF XAH XAF XAH XAF XAH 8HK(0,1)6500206 2.4 00-0001 00-0001 00-0001 00-0001 00-0001 00-0001 00-0001 00-0001 8HK(0,1)6500506 4.8 1 00-0010 01-0010 1 00-0010 00-0010 00-0010 00-0010 00-0010 00-0010 8HK(0,1)6500806 7.7 00-0011 01-0011 00-0011 00-0011 00-0011 00-0011 00-0011 00-0011 8HK(0,1)6501006 9.6 00-0100 00-0101 00-0100 00-0100 00-0100 00-0100 00-0100 00-0100 8HK(1,2)6501506 14.4 00-0101 01-0101 00-0101 00-0101 01-0101 01-0101 00-0101 01-0101 8HK(1,2)6502006 19.2 00-0110 00-0110 01-0110 01-0110"" 00-0110 00-0110 00-0110 00-0110 8HK(1,2)6502506 24 — — — — — — 00-0111 00-0111 1. (0,1) - 0 = no service disconnect or 1 = with service disconnect 2. (1,2) - 1 = with service disconnect, no breakerjumper bar or 2 = with service disconnect and breakerjumper bar The values in the table are represented as two digits followed by a set of four digits. The first two digits represent the airflow configuration - heat dip switch settings (00 = nominal, 01 = +20% CFM increase). The last four digits represent the auxiliary heat configuration - heat kit selection dip switch settings. 'To increase any airflow by approximately 20%, adjust the heat dip switches from 00 to 01, if not already assigned as required for minimum CFM to satisfy the kW specified in the table. "Heat kit kW not approved for horizontal right with heat pump application. Table 7: Electrical heat: minimum fan CFM dip switch settings for three-phase heat kits Heater kit Nominal Air handler models 12B 16C 17C 20D modelsl,2 kW at V Indoor coil XAF XAH XAF XAH XAF XAH XAF XAH product match 8HKO6501025 9.6 00-1000 00-1000 00-1000 00-1000 00-1000 00-1000 00-1000 00-1000 8HKO6501525 14.4 1 00-1001 01-1001 00-1001 01-1001 01-1001 01-1001 00-1001 00-1001 8HK16502025 19.2 00-1010 00-1010 01-1010 01-1010 00-1010 00-1010 00-1010 00-1010 8HK16502525 24 — — — — — — 00-1011 00-1011 1. (0,1) - 0 = no service disconnect or 1 = with service disconnect 2. (1,2) - 1 = with service disconnect, no breakerjumper bar or 2 = with service disconnect and breakerjumper bar The values in the table are represented as two digits followed by a set of four digits. The first two digits represent the airflow configuration - heat dip switch settings (00 = nominal, 01 = +20% CFM increase). The last four digits represent the auxiliary heat configuration - heat kit selection dip switch settings. 'To increase any airflow by approximately 20%, adjust the heat dip switches from 00 to 01, if not already assigned as required for minimum CFM to satisfy the kW specified in the table. Johnson Controls Ducted Systems 6269412-YTG-A-0922 Table 8: Auxiliary heat configuration - stage 1 kW dip switch settings W1 = W1 00,01 W1 = W2 10 W1 = W1 + W2 11 Table 9: kW and MBH conversions - for total power input requirement For a power distribution voltage that is different than the provided nominal voltage, multiply the kW and MBH data from the table by the conversion factor in the following table. Distribution power (V) Nominal voltage (V) Conversion factor 208 240 0.75 220 240 0.84 230 240 0.92 Table 10: Application factors - rated CFM vs actual CFM % of rated airflow (CFM) 80 90 100 110 120 Capacity factor 0.96 0.98 1.00 1.02 1.03 Table 11: Electric heat performance data: 208/230-1-60 and 208/230-3-60 Heater modelsl,2 Nominal kW at 240 V Total heat 3 kW staging kW MBH W1 only W1 and W2 208 V 230 V 208 V 230 V 208 V 230 V 208 V 230 V 8HK(0,1)6500206 2.4 1.8 2.2 6.2 7.5 1.8 2.2 1.8 2.2 8HK(0,1)6500506 4.8 3.6 4.4 12.3 15 3.6 4.4 3.6 4.4 8HK(0,1)6500806 7.7 5.8 7.1 19.7 24.1 5.8 7.1 5.8 7.1 Single 8HK(0,1)6501006 9.6 7.2 8.8 24.6 30.1 7.2 8.8 7.2 8.8 phase 8HK(1,2)6501506 14.4 10.8 13.2 36.9 45.1 3.6 4.4 10.8 13.2 8HK(1,2)6502006 19.2 14.4 17.6 49.2 60.2 7.2 8.8 14.4 17.6 8HK(1,2)6502506 24 18 22 61.5 75.2 7.2 8.8 18 22 8HK06501025 9.6 7.2 8.8 24.6 30.1 7.2 8.8 7.2 8.8 Three 8HK06501525 14.4 10.8 13.2 36.9 45.1 10.8 13.2 10.8 13.2 phase 8HK16502025 19.2 14.4 17.6 49.2 60.2 7.2 8.8 14.4 17.6 8HK16502525 24 18 22 61.5 75.2 9 11 18 22 1. (0,1) - 0 = no service disconnect or 1 = with service disconnect 2. (1,2) - 1 = with service disconnect, no breaker jumper bar or 2 = with service disconnect and breaker jumper bar 3. For different power distributions, see Table 9. Table 12: Electrical data for single -source power supply: 208/230-1-60 Modular blower models Heater models 2 Heater amps (A) at 240 V Field wiring Minimum circuit ampacity (A) MOPS (A) 208 V 230 V 208 V 230 V 8HK(0,1)6500206 10 15.6 16.7 20 20 8HK(0,1)6500506 20 26.4 28.7 30 30 JMVT12B 8HK(0,1)6500806 32 39.6 43.3 40 45 8HK(0,1)6501006 40 48.0 52.6 50 60 8HK(1,2)6501506 60 69.7 76.5 70 80 8HK(1,2)6502006 80 91.3 100.4 100 110 8HK(0,1)6500206 10 17.6 18.7 20 20 8HK(0,1)6500506 20 28.4 30.7 30 35 JMVT16C 8HK(0,1)6500806 32 41.6 45.3 45 50 8HK(0,1)6501006 40 50.0 54.6 50 60 8HK(1,2)6501506 60 71.7 78.5 80 80 8HK(1,2)6502006 80 93.3 102.4 100 110 Johnson Controls Ducted Systems 6269412-YTG-A-0922 Table 12: Electrical data for single -source power supply: 208/230-1-60 (continued) Modular blower models Heater modelsl Z Heater amps (A) at 240 V Field wiring Minimum circuit ampacity (A) MOPS (A) 208 V 230 V 208 V 230 V 8HK(0,1)6500206 10 19.6 20.7 20 25 8HK(0,1)6500506 20 30.4 32.7 35 35 JMVT17C 8HK(0,1)6500806 32 43.6 47.3 45 50 8HK(0,1)6501006 40 52.0 56.6 60 60 8HK(1,2)6501506 60 73.7 80.5 80 90 8HK(1,2)6502006 80 95.3 104.4 100 110 8HK(0,1)6500206 10 19.6 20.7 20 25 8HK(0,1)6500506 20 30.4 32.7 35 35 8HK(0,1)6500806 32 43.6 47.3 45 50 JMVT20D 8HK(0,1)6501006 40 52.0 56.6 60 60 8HK(1,2)6501506 60 73.7 80.5 80 90 8HK(1,2)6502006 80 95.3 104.4 100 110 8H K(1,2)6502506 100 116.9 128.3 125 150 1. (0,1) - 0 = no service disconnect or 1 = with service disconnect 2. (1,2) - 1 = with service disconnect, no breaker jumper bar or 2 = with service disconnect and breaker jumper bar 3. MOP (Maximum Overcurrent Protection) device - must be HACR type circuit breaker or time delay fuse. Refer to the latest edition of the National Electric Code or in Canada the Canadian Electrical Code and local codes to determine correct wire sizing. Table 13: Electrical data for multi -source power supply: 208/230-1-60 Modular blower models Heater models1,2 Heater amps (A) at 240 V Minimum circuit ampacity (A) M0p3 (A) 208 V 1230 V 208 V 1230 V Circuit Circuit First3 Second Third First3 Second Third First3 Second Third First3 Second Third JMVT12B 8HK16501506 60 26.2 43.5 - 28.4 48.1 - 30 45 - 30 50 - 8HK16502006 80 48.0 43.3 - 52.6 47.8 - 50 45 - 60 50 - JMVT16C 8HK16501506 60 28.2 43.5 - 30.4 48.1 - 30 45 - 35 50 - 8HK16502006 80 50.0 43.3 - 54.6 47.8 - 50 45 - 60 50 - JMVT17C 8HK16501506 60 30.2 43.5 - 32.4 48.1 - 35 45 - 35 50 - 8HK16502006 80 52.0 43.3 - 56.6 47.8 - 60 45 - 60 50 - 8HK16501506 60 30.2 43.5 - 32.4 48.1 - 35 45 - 35 50 - JMVT20D 8HK16502006 80 52.0 43.3 - 56.6 47.8 - 60 45 - 60 50 - 8HK16502506 100 52.0 43.3 21.6 56.6 47.8 23.9 60 45 25 60 50 25 1.(0,1) - 0 = no service disconnect or 1 = with service disconnect 2. (1,2) - 1 = with service disconnect, no breaker jumper bar or 2 = with service disconnect and breaker jumper bar 3. MOP (Maximum Overcurrent Protection) device - must be HACR type circuit breaker or time delay fuse. The first circuit includes blower motor amps. Refer to the latest edition of the National Electric Code or in Canada the Canadian Electrical Code and local codes to determine correct wire sizing. Table 14: Electrical data for single source power supply: 208/230-3-60 Modular blower models Heater modelsl Heater amps (A) at 240 V Field wiring Minimum circuit ampacity (A) M0p2 (q) 208 V 230 V 208 V 230 V BHK06501025 23.1 29.7 32.4 30 35 JMVT12B 8HK06501525 34.6 42.2 46.2 45 50 8HKO65020253 46.2 54.7 60.0 60 60 8HKO6501025 23.1 31.7 34.4 35 35 JMVT16C 8HKO6501525 34.6 44.2 48.2 45 50 8HKO5020253 46.2 56.7 62.0 60 70 8HKO6501025 23.1 33.7 36.4 35 40 JMVT17C 8HKO6501525 34.6 46.2 50.2 50 60 8HKO65020253 46.2 58.7 64.0 60 70 Johnson Controls Ducted Systems 9 6269412-YTG-A-0922 Table 14. Electrical data for single source power supply: 208/230-3-60 (continued) Modular blower models Heater modelsl Heater amps (A) at 240 V Field wiring Minimum circuit ampacity (A) MOP Z (A) 208 V 230 V 208 V 230 V 8HKO6501025 23.1 33.7 36.4 35 40 8HKO6501525 34.6 46.2 50.2 50 60 JMVT20D 8HK065020253 46.2 58.7 64.0 60 70 8HKO65025253 57.7 71.2 77.8 80 80 1.0 = no service disconnect or 1 = with service disconnect. The 20 kW and 25 kW heater models (8HK16502025 and 8HK16502525) come with service disconnects standard. Single source power MCA and MOP requirements are given here only for reference if used with field installed single point power modification. 2. MOP (Maximum Overcurrent Protection) device - must be HACR type circuit breaker or time delay fuse. The first circuit includes blower motor amps. Refer to the latest edition of the National Electric Code or in Canada the Canadian Electrical Code and local codes to determine correct wire sizing. Table 15: Electrical data for multi -source power supply: 208/230-3-60 Air handlers models Heater models Heater amps (A) at 240V Minimum circuit ampacity (A) M0P2 (A) 208V I 230V 208V I 230V Circuit Circuit First2 Second First2 Second First2 Second First2 Second 12B 8HK16502025 46.2 29.7 25.0 32.4 27.6 30 25 35 30 16C 8HK16502025 46.2 31.7 25.0 34.4 27.6 35 25 35 30 17C 8HK16502025 46.2 33.7 25.0 36.4 27.6 35 25 40 30 20D 8HK16502025 46.2 33.7 25.0 36.4 27.6 35 25 40 30 8HK16502525 57.7 40.0 31.2 43.3 34.5 40 35 45 35 1. The 20 kW and 25 kW heater models (8HK16502025 and 8HK16502525) come with circuit breakers standard. 2. MOP (Maximum Overcurrent Protection) device - must be HACR type circuit breaker or time delay fuse. The first circuit includes blower motor amps. Refer to the latest edition of the National Electric Code or in Canada the Canadian Electrical Code and local codes to determine correct wire sizing. 10 Johnson Controls Ducted Systems Power wiring 6269412-YTG-A-0922 1 Phase Electric Heat Power Options: Single source power GND��I T Power supply { L1 — — Terminal block or service disconnect Multi -source power with jumper bar GND null T { SD Power supply{ L1 SD Jumper bar { SD Two circuits on 15 kW to 20 kW Three circuits on 25 kW 3 Phase Electric Heat Power Options: Single source power Multi -source power GND�PII L3_� Power supply { L2_ _ _ � Power supply L1---_-U: Terminal block or service disconnect No Electric Heat: GND_II I__2 Power supply _ _ —] CN CN Figure 2: Power wiring - line connections GND_VII1 T _ L3 __ CKT 2 { L2 _ _ SD L1 — L3 — — � CKT 1 { L2 SD L1 — — Accessories Refer to Price Manual for specific model numbers where not shown. Electric heaters - 8HK models shown under electrical data include sequential operation and temperature dual limit switches for safe, efficient operation. Service disconnects are provided where shown. Single source power accessories (single-phase) S1-02435670000 For heat kits with two service disconnects. S1-02435671000 For heat kits with three service disconnects. Single source power accessory (three-phase) S1-32436041000 Contains a terminal block and wiring to connect service disconnects together. Combustible floor base accessory - If an electric heat accessory which is rated for greater than zero clearance to combustible surfaces is installed in these air handlers in the downflow operating positions on a combustible floor, one of the following combustible floor base accessory models is required: S1-1FB1917, S1-1FB1921, orS1-1FB1924. Thermostat - Compatible thermostat controls are available through accessory sourcing. For optimum performance, these outdoor units are fully compatible with our YORK touch screen thermostat with proprietary (patent -pending) hexagon interface. Multi -source power GND�-�111 I CKT 3 ` Power supply { tL1- — — U SD CKT 2{ Lt1- {- - SD �— CKT 1 L1_ _ - 1 SD Two circuits on 15 kW to 20 kW Three circuits on 25 kW Component Codes: GND - Ground lug SD - Service disconnect CKT - Circuit CN - Wire connector/nut — — _ Field power wiring (208/230 V) niesaoa1 For more information, see the thermostat section of the Product Equipment Catalog. Breaker moisture seal accessory - A clear circuit breaker moisture barrier seals the breakers from humidity and dust. The flexibility of the clear cover allows circuit breakers to be turned ON or OFF without removing the cover. The cover firmly attaches to the access panel around the circuit breakers with the use of double backed adhesive tape. To ensure that moisture or dust does not contaminate circuit breakers, an S1- 02435672000, Circuit Breaker, Cover Seal may be ordered. Johnson Controls Ducted Systems 11 6269412-YTG-A-0922 B DOWNFLOW AIR HANDLER WARM AIR PLENUM with 1" flange out on each side. A B� FIBERGLASS j INSULATION FIBERGLASS TAPE under flange. BUSTIBLE FLOOR ACCESSORY Figure 3: Combustible floor base accessory Table 16: Combustible floor base accessory dimensions AIR HANDLER - DEPTH 111 %FLOOR 11" APPROX.1/2" PLENUM CLEARANCE ALLAROUND 1" 13" FLOOR OPENING CROSS SECTION (A -A) FROM SIDE A AIR HANDLER WIDTH COMBUSTIBLE FLOOR BASE FLOOR 14 B PLENUM APPROX. 1 /2" CLEARANCE 1„ ALLAROUND C 1" FLOOR OPENING CROSS SECTION (B-B) FROM FRONT A04hb001 Floor base models Used with Dimensions (in.) A B C 1 FB1917 JMVT12B 17.5 14.0 16.0 1 FB1921 JMVT16C, JMVT17C 21.0 17.5 19.5 1 FB1924 JMVT20D 24.5 21.0 23.0 Limitations These units must be wired and installed in accordance with all national and local safety codes. Voltage limits are as follows: Normal Operating Air Handler Voltage Voltage code Voltage Rangel 208/230-1-60 06 187-253 1. Rated in accordance with ARI Standard 110, utilization range A. Airflow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units. 12 Johnson Controls Ducted Systems 6269412-YTG-A-0922 Typical applications Upflow Uowntlow 9-" Heat kit broil W dd bb Horizontal right b � o N !llit Heat kit g o `yab •®�• .4 Horizontal left A1822-001 Figure 4: Typical applications Control wiring Air handler control wiring Typical AC with cooling only applications Thermostat Air handler board Single -stage air conditioning R R G G Y Y/Y2 Y W1 Y1 W2 W2 C W1 HUMIDISTAT O HUM C (COM) C Air handler control wiring Typical AC with electric heat applications Thermostat Air handler board Single -stage air conditioning R R G G Y Y/Y2 Y Y1 W2 W2 W1 W1 HUMIDISTAI C O HUM C C COM Accessory control wiring Air handler board HUM EAC ELECTRICAIR CLEANER RELAY Figure 5: Cooling models with and without electric heat wiring Notes: • The Y/Y2 thermostat wire must be connected for full CFM and applications requiring 60 s blower off delay for SEER enhancement. • If a humidistat is connected to the HUM input, change the humidistat dip switch to the 1 (ON) position. • The control is factory set for HP applications. For AC applications, change the AC/HP dip switch to the 1 (ON) position. • Air handler control wiring only: Optional dehumidification humidistat switch contacts open on humidity rise. 24V HUMIDIFIER RELAY HUMIDISTAT A1724-001 Johnson Controls Ducted Systems 13 ror rigure b: Room thermostat reversing valve operation must be set to B - ener- gize during heating operation. S1 mode must be enabled for correct operation. Refer to the required control set up section in the unit Installation manual. Figure 6: Control wiring -premium ECM blower and HMH7 heat pump - conventional wiring Multi -stage Thermostat Air handler air conditioner A1727-001 R R R R G Y2 G Y2 Y / Y2 Y2 OUT Y1 Y1 y1 W2 W2 W1 Figure 7: Control wiring - premium ECM blower and multi -stage air conditioner - conventional wiring Airflow data Table 17: Airflow data (CFM per Watts) ror t-igure ts: Do not bond any of the outdoor unit W wires together. W2 OUT is only required for heat kits with multiple stages of electric heat. Refer to the wiring diagram for the heat kit used to determine stages of heat. Multi -stage Thermostat Air handler heat pump A1728001 0 _ o�� o Figure 8: Control wiring - premium ECM blower and multi -stage heat pump - conventional wiring Figure 9: Control wiring -premium ECM blower and single -stage heat pump -conventional wiring Dip switch setting JMVT12B JMVT16C JMVT17C JMVT20D High cool Low cool High cool Low cool High cool Low cool High cool Low cool 000 800 550 1100 700 1150 725 1500 925 001 900 600 1200 750 1250 775 1475 1050 010 975 650 1300 800 1350 850 1750 1125 011 1075 700 1400 850 1450 900 1875 1225 100 1150 775 1500 925 1575 975 2000 1350 101 1250 825 1625 975 1675 1025 2000 1400 110 1325 900 1725 1050 1775 1100 2000 1475 111 1400 950 1825 1100 1875 1150 2000 1575 Notes: Air handler units have been tested to UL 60335-2-40 / CSA 22.2 No. 236 standards up to 0.6 in. W.C. external static pressure. Dry coil conditions only, tested without filters. • For optimal performance, external static pressures of 0.2 in. W.0 to 0.5 in. W.0 are recommended. Heating applications tested at 0.5 in. W.C. external static pres- sure. Above 0.5 in. W.C., CFM is reduced by 2% per 0.1 in. increase in static. • Low speed cooling used only with two stage outdoor units. Speed is preset to 65% of high speed. • Dehumidification speed is 85% of jumper selected cool tap. • Any compressor operation uses high cool and low cool dip switches. Indoor heating operates off the heat kit selection and the heat dip switches. • At some settings, low cool and/or low heat airflow may be lower than what is required to operate an airflow switch on certain models of electronic air cleaners. Con- sult the instructions for the electronic air cleaner for further details. • Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (for example, 12 flashes is 1200 CFM) - blinks are approximate t10% of actual CFM. Subject to change without notice. Published in U.S.A. Copyright © 2022 by Johnson Controls. All rights reserved. 6269412-YTG-A-0922 Supersedes: nothing York International Corp. 5005 York Drive Norman, OK 73069 Notes: Air handler units have been tested to UL 60335-2-40 / CSA 22.2 No. 236 standards up to 0.6 in. W.C. external static pressure. Dry coil conditions only, tested without filters. • For optimal performance, external static pressures of 0.2 in. W.0 to 0.5 in. W.0 are recommended. Heating applications tested at 0.5 in. W.C. external static pres- sure. Above 0.5 in. W.C., CFM is reduced by 2% per 0.1 in. increase in static. • Low speed cooling used only with two stage outdoor units. Speed is preset to 65% of high speed. • Dehumidification speed is 85% of jumper selected cool tap. • Any compressor operation uses high cool and low cool dip switches. Indoor heating operates off the heat kit selection and the heat dip switches. • At some settings, low cool and/or low heat airflow may be lower than what is required to operate an airflow switch on certain models of electronic air cleaners. Con- sult the instructions for the electronic air cleaner for further details. • Airflow (CFM) indicator light (LED2) flashes once for every 100 CFM (for example, 12 flashes is 1200 CFM) - blinks are approximate t10% of actual CFM. Subject to change without notice. Published in U.S.A. Copyright © 2022 by Johnson Controls. All rights reserved. 6269412-YTG-A-0922 Supersedes: nothing York International Corp. 5005 York Drive Norman, OK 73069