APPROVED RESUB1 FIR2024-0119+Fire_Sprinkler_Plan+12.17.2024_2.50.25_PM+4674960BATHROOMS UNDER 55 S.F. DO NOT RE UIRE PROTECTION PER ", �� • a //// / /////I ���• I r.• IS • _ -61-011 EXERCISE C .1' M �p Pgp�E 1 10'-3" 1 6'-5" 2'- BASEMENT LEVEL PLAN SCALE. 1/4 - 1-0 CLOSETS UNDER 24 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.3. TYP. CALC. 877 t`HR BATH ROO1 S.F. DO NO PROTECTI( NFPA-13D CLOSETS UNDER 24 S.F. DO NOT REQUIF PROTECTION PER NFPA-13D 8.3.3. TYP N9?5? FIX/FIX/CAS 6 UPPER LEVEL PLAN BATH ROON S.F. DO NO' PROTECTIC NFPA-13D TEST HEAD mi - IuFill 1100wimm0Ii\\ DESIGN DENSITY:I CALC, S170rHR BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER N O NOTES J�� REV BY CHK'D DATE DESCRIPTION SPRINKLER INFORMATION '---- -- -� ECLIPSE FIRE SPRI\KLERS, LLC It 1 8TH AX7 E \ ALGO\ A, WA 98001 = . HELLOGECLIPSEFIRE.CONI ECLIPSE O 6 - ! (- 31 O:� ,..�,� DESIGNED BY is PROJEC 7905 - FIRE SPRINKLER HEAD LOCATION MAY VARY FROM PRINT SYM CNT TYPE METAL TEMP K NPT MFG. MODEL# ESCUTCHEON DRAWfJRY: BUT WILL MAINTAIN LISTED HEAD SPACING. 14 PENDENT(14'x14') BRASS 162° 3.7 1/2" SENJU SS8261 CONC. ALL CEILING'S ARE FLAT UNLESS OTHERWISE NOTED CHECKED BY: DATE: 27 OCT, 2024 O 02 INTER. PENDENT BRASS 205° 4.9 1/2" SENJU SS8464 DUE CARE WILL BE TAKEN TO ENSURE SPRINKLER HEAD 31 PENDENT(16'x16') BRASS 162' 4.9 1/2" SENJU SS8464 CONC. COVERAGE IS NOT OBSTRUCTED BY LIGHTS, FANS, ETC.... C r O 01 PENDENT BRASS 360' 5.6 1/2" VIKING VK102 ELECTRICIANS WILL PROVIDE & HOOK UP POWER TO PUMP PLUMBERS WILL PROVIDE WATER FOR THE OPTIONAL AUTOFILL TOTAL HEADS 48 SCALE: AS SPECIFIED T: EDMONDS RESIDENCE LOT- 2 240TH STREET SOUTHWEST, EDMONDS, WASHINGTON JOB# DRAWING SHEET: 'IRE PROTECTION 1 OF 2 PLAN 5)AFCON 515 DOUBLE OFFSET HANGER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. -0 #2530180 OFFSET CPVC HANGER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. HANGER DETAILS N.T.S I I I I I I I 1 1 I 01 OI 01 Cn I of LbI �I I I I I I I I I I HEX HEAD SELF TAPPING SCREW CPVC DOUBLE FASTENER STRA TOLCO FIG. #24 do 0 HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. INSULATION CVPC PIPE BY OTHERS STAPLE >I LAIR GX�y (UPPER FLOOR ONLY) L CEILING INSULATION DETAIL N.T.S AI� A 5 U M M P,,, Y BASEMENT LEVEL MAIN LEVEL UPPER LEVEL TOTAL AREA GARAGE PORCH & DECKS 1931.00 sqF 1533.00 sqF 1 41 6.00 sq F 4880.00 sqF 462.00 sq F 377.00 sqF HYDRAULIC CALCULATION SUMMARY CALCULATED DENSITY LOCATION REl'D FLOW AT REQ'D PRESSURE EXCESS RESIDUAL AREA USGPM/SQ.FT. INFLOW NODE AT INFLOW NODE AT INFLOW NODE SAFETY FACTOR (14' X 14') L.H 0.05 USGPM/SQ.FT. / 2 HEAD CALC UPPER FLOOR 20.0 US GPM 49.2 PSI 15.8 PSI 24.30 % (16' X 16') L.H 0.05 USGPM/SQ.FT. / 1 HEAD CALC UPPER FLOOR 13.0 US GPM 42.8 PSI 22.2 PSI 34.15% _� __ __ __ 127.00' N88031'13 W FIRE APPARATUS TURN -AROUND - SOOPFrOEJI1LORK 7.50' SY BS 42" C GRASS FLOW PATH 12" TRENCH DRAIN 0.00' ACCESS EASEMEN (SOURCE) 127.00' S 8803113" E N SITE PLAN scale 1/ 99 ] 9 O" ROOF LEVEL RIDGE EL374.17' UPPER LEVEL PLATE El 3.14' UPPER LEVEL FLOOR 516:4.04' MAIN LEVEL PLATE EL363.00' MAIN LEVEL FLOOR EL353.90' BASEMENT PLATE EL:352.84' AVERAGE GRADE EL: 350.52' BASEMENT FLOOR EL:343.7�_ - N 6 ELEVATION DRAWING scale 1/419 = 19-099 NOTES N FIRE SPRINKLER HEAD LOCATION MAY VARY FROM PRINT BUT WILL MAINTAIN LISTED HEAD SPACING, ALL CEILING'S ARE FLAT UNLESS OTHERWISE NOTED O DUE CARE WILL BE TAKEN TO ENSURE SPRINKLER HEAD COVERAGE IS NOT OBSTRUCTED BY LIGHTS, FANS, ETC.... ELECTRICIANS WILL PROVIDE & HOOK UP POWER TO PUMP PLUMBERS WILL PROVIDE WATER FOR THE OPTIONAL AUTOFILL REV I BY ICHK'D I DATE I DESCRIPTION S P RINUE R INFORMATION SYM CNT TYPE METAL TEMP K NPT MFG. MODEL# ESCUTCHEON 14 PENDENT (14'x14') BRASS 162' 3.7 1/2" SENJU SS8261 CONC. O 02 INTER. PENDENT BRASS 205' 4.9 1/2" SENJU SS8464 31 PENDENT (16'x16') BRASS 162' 4.9 1/2" SENJU SS8464 CONC. OO 01 PENDENT BRASS 360° 5.6 1/2" VIKING VK102 rn rn rn FLOW TEST SUMMARY HEAD LAYOUT MAY BE Static 65 PSI DIFFERENT THEN PRINT Residual 20 PSI DUE TO LIGHT AND/OR HEAT REGISTER Flow 2000 GPM LOCATIONS BUT WILL MAINTAIN LISTED HEAD SPACINGS FIRE SUPPRESSION DESIGN NOTES 1. CODES, STANDARDS AND APPROVALS DESIGN, INSTALLATION, AND TESTING SHALL CONFORM TO THE FOLLOWING 1.1 NFPA-13D -EDITION 2016 1.2 NATIONAL FIRE PROTECTION ASSOCIATION # 13D 2.0 DESCRIPTION OF WORK THE FOLLOWING FIRE PROTECTION SYSTEMS ARE INCLUDED IN THIS SECTION OF 2.1 NEW WET SPRINKLER SYSTEM 2.2 RESIDENTIAL LEVEL'S DESIGN DENSITY OF 0.05 USGPM/SQFT 1 HEAD CALC 13 GPM PER HEAD DESIGN DENSITY OF 0.05 USGPM/SQFT 2 HEAD CALC 10 GPM PER HEAD 3.0 PUMP SUPPLY INFORMATION STATIC PRESSURE: 65 PSI RESIDUAL PRESSURE: 20 PSI @ 2000 USGPM 4.0 MATERIALS & EQUIPMENT ALL FIRE PROTECTION MATERIALS AND EQUIPMENT INSTALLED AS PART OF THIS CONTRACT SHALL BE BE CUL LISTED AND FULLY CONFORM TO NFPA STANDARDS 4.1 CPVC FOR SIZES 3/4" - 2" UNLESS NOTED FITTING'S GLUED OR GROOVED 4.2 HANGERS AND SUPPORTS ALL HANGERS AND SUPPORTS SHALL BE CUL LISTED FOR FIRE PROTECTION USE AND MEET THE NFPA REQUIREMENTS. ALL HANGER AND SUPPORTS TO BE INSTALLED IN ACCORDANCE WITH NFPA AND THE MANUFACTURER'S SPECIFICATIONS. 5.0 DESIGN STANDARDS 1. BATHROOMS UNDER 55 S.F DO NOT REQUIRE PROTECTION PER NFPA-13D 8.23. 2. CLOSETS UNDER 24 S.F DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.3. 3. SPRINKLERS ARE SPACED TO A MAX OF 16'x16' (256 SQ.FT.) 14'X14' (196 SQ.FT) 4. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE PER NFPA-13D 83.5. 7- ICPVC TO UPPER LEVEL / I" CPVC TO MAIN LEVEL RISER SCHEMATIC DESIGNED BYt PROJECT: TOTAL HEADS 48 EDMONDS RESIDENCE LOT- 2 DRAWN BY: CHECKED BY: 7905 - 240TH STREET SOUTHWEST,EDMONDS, WASHINGTON DATE: 27 DATE: 2024 JOB# DRAWING SHEET: REV: SCALE: FIRE PROTECTION 2 OF 2 AS SPECIFIED PLAN