APPROVED RESUB1 FIR2024-0117+Fire_Sprinkler_Plan+12.17.2024_2.51.27_PM+4674972BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.2, (TYP.) `g MEDIA HARDWOOD 4 1" 9'-7" T-1to " 3 °B N WINE/TASTING SLATE 4 21 11„ 3'-8" T-11" UP UTILITY 29 1 13 S.0. G. 3 ) )HALL N /4-IARDW00± 2 12 3 11 3 4 5 6 7 8 9 10 N wH i (V 1,_ " 1.25' 31 -10" 1.0" FIRE SAUNA n SPRINKLER RISER o CEDAR E, 360°F 1 4 HEATER 9'- ^ N N EXERCISE r, DRIDEK? En 4 1„ r~ 2'-Y N BASEMENT LEVEL PLAN SCALE: 1/4" = 1'-0" Approved with Conditions Fire Marshal Chris Burt 12/19/2024 12-19-2024 RESUB 1 PLAN REVIEW NOTES: APPROVED WITH CONDITIONS: 1. Approved set of plans must be on site at the time of inspection. Failure to provide the approved plan may result in a re -inspection fee. System drain(s):. If riser is above lowest grade, 2nd drain required and signage at riser indicating location is required. Systems required signage IAW NFPA 13D. 2. Coverage required to the following areas: Clothes closets, linen closets and pantries exceeding 24 square feet in area, with the smallest dimension greater than 3' and having wall and ceiling surfaces of gypsum board. Bathrooms more than 55 square feet in area. When fuel fired equipment is present on covered decks or porches, or if living space above, at least one quick -response intermediate temperature sprinkler shall be installed above equipment or area under living space. All fuel fired appliances except attics if above all living areas. DFM Burt NOTES N FIRE SPRINKLER HEAD LOCATION MAY VARY FROM PRINT BUT WILL MAINTAIN LISTED HEAD SPACING. ALL CEILING'S ARE FLAT UNLESS OTHERWISE NOTED DUE CARE WILL BE TAKEN TO ENSURE SPRINKLER HEAD 6 COVERAGE IS NOT OBSTRUCTED BY LIGHTS, FANS, ETC.... ELECTRICIANS WILL PROVIDE & HOOK UP POWER TO PUMP PLUMBERS WILL PROVIDE WATER FOR THE OPTIONAL AUTOFILL 4 BONUS HARDWOOD o? Y4 7 7 r—6'-7"— OFFICE HARDWOOD HARDWOOD N � � [V zz Cq 0 � N 1' 1 L KITCHEN 1„ HARDWOOD 36" REF 36" FZR 1" '-2" 12 4 2' -10" m CLOSETS UNDER24 ENTRY SLATE %" 0 S.F. DO NOT REQUIRE THIS AREA PROTECT Y4 17 10'-9" DINING 13'-5" PROTECTION PER FROM ABOVE o HARDWOOD N NFPA. 13D 8.3.3, TYP. MOU 4 1' 1 V" L19 BED-1 HARDWARE II W.I.C. II HARDWARE II II "II II ,� II II II II II II ------------- BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.2, (TYP.) HYDRAULIC NOTES NO. OF SPRINKLERS: DESIGN DENSITY. Q,Qj AREA OF DISCHARGE: 392 s ft SYSTEM DEMAND: 20.0 gm — RESIDUAL PRESSURE ® BASE OF RISER: 3.4 SI CAL C..S77CKHR BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13 D 8.3.2, (TYP.) BED-2 CARPET 4 12'-9"— M. BATH HTD TILE 3? CURBLESS SH Li ofm Q J Q O Li X Li O (c W \_ z 0 J = � O O BATHROOMS UNDER 55 S.F. DO NOT REQUIRE j PROTECTION PER j NFPA-13D 8.3.2, (TYP.) BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.2, (TYP.) +36" OPEN GUARDRAIL (TYP) 4 8-1 OPEN OPEN TO BELO`A 4 l 1f7 2'-9" 8'-3'' D W 1" 4'-0" 3'-6" 1? 205OF 12'-7" 1 TI LE UP DN 4 OPE 3 2 ELO 2 3 11 4 5 6 7 8 9 10 4 7 7'-9" X (2) CAR GARAGE S.O.G. N MAIN LEVEL PLAN 6 SCALE: 1/4" = 1'-n" 4 7'-4" - BED-3 CARPET 0 y4 1 \ 2'-5" „ COMMON N 1 CARP T 1-------- ;,_7„ II W.I.C. II CARPET II -Z7) DN AIIIIIIIIIIIIII LMMM ®// r� 41 111 % miM / N TEST HEAD � � UPPER LEVEL PLAN REV I BY ICHK'D I DATE I DESCRIPTION 1" 11'-7' SPRINKLER INFORMATION SYM CNT TYPE METAL TEMP K NPT MFG. MODEL# ESCUTCHEON 09 PENDENT (14'xl4') BRASS 162° 3.7 1/2" SENJU SS8261 CONC. O 02 INTER. PENDENT BRASS 205' 4.9 1/2" SENJU SS8464 33 PENDENT(16'x16') BRASS 162' 4.9 1/2" SENJU SS8464 CONC. OO 01 PENDENT BRASS 360° 5.6 1/2" VIKING VK102 TOTAL HEADS 45 4 BED-4 \ CARPET 1" 14'-3" OP FIR-F�E rn BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13 D 8.3.2, (TYP.) BATHROOMS UNDER 55 S.F. DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.2, (TYP.) HYDRAULIC NOTES NO. OF SPRINKLERS: DESIGN DENSITY. 0,0rj AREA OF DISCHARGE: 256 s ft SYSTEM DEMAND: 13.0 gpm RESIDUAL PRESSURE ® BASE OF RISER: 22.4 SI CAL C..S7210MIF SEAT DWOOD TSG 0 0 0 X C• W.P. DECK COMPOSITE F I R2024-0117 ---- Ex Tres WASHINGTON STATE DEC3'I, 24 CERTIFICATE OF COMPETENCY i FIRE SPRINKLER SYSTEMS John Shakespeare : 7566-0908-A"-H Level 1 : Eclipse Fire Sprinklers, LLC ECLIPFS783DP 11 /29/24 : '�/?�SIg atare Date RESUB ---------------------------.a Dec 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICE DEPARTMENT DESIGNED BY PROJECT: is EDMONDS RESIDENCE LOT- 4 DRAWN BY: ECLIPSE FIRE SPRINKLERS, LLC is It 1 8TH AVE N ALGONA, IVA 98001 CHECKED BY: 7907 - 240TH STREET SOUTHWEST, EDMONDS, WASHINGTON HELLO GECLIPSEFIRE. CO -NI 6CLSE 206— —3105 �SPMWLM DATE: JOB# DRAWING SHEET: REV: 28 OCT, 2024 FIRE PROTECTION SCALE: 1 O F 2 AS SPECIFIED PLAN 5)AFCON 515 DOUBLE OFFSET HANGER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. 0 #2530180 OFFSET CPVC HANGER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. HANGER DETAILS N.T.S F"""' row I 1 N 6 SITE PLAN scale 1 /4" - 1' 0" ROOF LEVEL RIDGE EL373.73' UPPER LEVEL PLATE HEX HEAD SELF TAPPING SCREW CPVC DOUBLE FASTENER STRA TOLCO FIG. #24 4 6 HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER. INSULATION CVPC PIPE BY OTHERS STAPLE 1 &0, 7 L LAIR GA (UPPER FLOOR ONLY) CEILING INSULATION DETAIL N.T.S AI� A 5UMMFI�Y BASEMENT LEVEL MAIN LEVEL U P P E R LEVEL TOTAL AREA GARAGE PORCH & DECKS 1955.00 s q F 1 581 .00 sq F 1789.00 s q F 5325.00 sq F 462.00 sqE 51 .00 sq F HYDRAULIC CALCULATION SUMMARY CALCULATED DENSITY LOCATION REQ'D FLOW AT REQ'D PRESSURE EXCESS RESIDUAL SAFETY FACTOR AREA USGPM/SQ.FT. INFLOW NODE AT INFLOW NODE AT INFLOW NODE (14' X 14') L.H 0.05 USGPM/SQ.FT. / 2 HEAD CALC UPPER FLOOR 20.0 US GPM 51.6 PSI 13.4 PSI 20.61 % (16' X 16') L.H 0.05 USGPM/SQ.FT. / 1 HEAD CALC UPPER FLOOR 13.0 US GPM 42.6 PSI 22.4 PSI 34.46% 127.00' N 8931'13" W -- - -I- =i-=--I=-I--I-=I==I==l== 127.00' S 8&31'13" E _ I _ _ I I SCOPE OF WORK I � I W I � I0 w -o IO I Ip o IO I II I I I � I I I I LOT 4 LOT 3 bo UPPER LEVEL FLOOR 56:4.60' MAIN LEVEL PLATE EL363.55' a MAIN LEVEL FLOOR EL354.89' BASEMENT PLATE EL:353.83' AVERAGE GRADE EL: 349.80' BASEMENT FLOOR EL:346.00' N 6 ELEVATION DRAWING scale 1 /4 of = 11-011 NOTES N FIRE SPRINKLER HEAD LOCATION MAY VARY FROM PRINT BUT WILL MAINTAIN LISTED HEAD SPACING, ALL CEILING'S ARE FLAT UNLESS OTHERWISE NOTED DUE CARE WILL BE TAKEN TO ENSURE SPRINKLER HEAD 6 COVERAGE IS NOT OBSTRUCTED BY LIGHTS, FANS, ETC.... ELECTRICIANS WILL PROVIDE & HOOK UP POWER TO PUMP PLUMBERS WILL PROVIDE WATER FOR THE OPTIONAL AUTOFILL REV BY ICHK'D I DATE I DESCRIPTION S PRINK;�ER INFORMATION SYM CNT TYPE METAL TEMP K NPT MFG. MODEL# ESCUTCHEON 09 PENDENT(14'x14') BRASS 162' 3.7 1/2" SENJU SS8261 CONC. O 02 INTER. PENDENT BRASS 205' 4.9 1/2" SENJU SS8464 33 PENDENT(16'x16') BRASS 162' 4.9 1/2" SENJU SS8464 CONC. O 01 PENDENT BRASS 360' 5.6 1/2" VIKING VK102 CP 0o 0 FLOW TEST SUMMARY HEAD LAYOUT MAY BE Static 65 PSI ///'DIFFFERENT THEN PRINT Residual 20 PSI DUE TO LIGHT AND/OR HEAT REGISTER Flow 2000 GPM LOCATIONS BUT WILL MAINTAIN LISTED HEAD SPACINGS FIRE SUPPRESSION DESIGN NOTES 1. CODES, STANDARDS AND APPROVALS DESIGN, INSTALLATION, AND TESTING SHALL CONFORM TO THE FOLLOWING 1.1 NFPA-13D -EDITION 2016 1.2 NATIONAL FIRE PROTECTION ASSOCIATION # 13D 2.0 DESCRIPTION OF WORK THE FOLLOWING FIRE PROTECTION SYSTEMS ARE INCLUDED IN THIS SECTION OF 2.1 NEW WET SPRINKLER SYSTEM 2.2 RESIDENTIAL LEVEL'S DESIGN DENSITY OF 0.05 USGPM/SQFT 1 HEAD CALC 13 GPM PER HEAD � DESIGN DENSITY OF 0.05 USGPM/SQFT 2 HEAD CALC 10 GPM PER HEAD 3.0 PUMP SUPPLY INFORMATION STATIC PRESSURE: 65 PSI RESIDUAL PRESSURE: 20 PSI @ 2000 USGPM 4.0 MATERIALS &EQUIPMENT ALL FIRE PROTECTION MATERIALS AND EQUIPMENT INSTALLED AS PART OF THIS CONTRACT SHALL BE BE CUL LISTED AND FULLY CONFORM TO NFPA STANDARDS 4.1 CPVC FOR SIZES %4" - 2" UNLESS NOTED FITTING'S GLUED OR GROOVED 4.2 HANGERS AND SUPPORTS ALL HANGERS AND SUPPORTS SHALL BE CUL LISTED FOR FIRE PROTECTION USE AND MEET THE NFPA REQUIREMENTS. ALL HANGER AND SUPPORTS TO BE INSTALLED IN ACCORDANCE WITH NFPA AND THE MANUFACTURER'S SPECIFICATIONS. 5.0 DESIGN STANDARDS 1. BATHROOMS UNDER 55 S.F DO NOT REQUIRE PROTECTION PER NFPA-13D 8.2.3. 2. CLOSETS UNDER 24 S.F DO NOT REQUIRE PROTECTION PER NFPA-13D 8.3.3. 3. SPRINKLERS ARE SPACED TO A MAX OF 16'x16' (256 SQ.FT.) 14'X14' (196 SQ.FT) 4. SPRINKLERS SHALL NOT BE REQUIRED IN ATTICS WITH OR WITHOUT STORAGE PER NFPA-13 D 8.3.5. 1" CPVC TO UPPER LEVEL / 1" CPVC TO MAIN LEVEL F I R2024-0117 RISER SCHEMATIC DESIGNED BYf PROJECT: RESUB Dec 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT TOTAL HEADS 45 Ex Tres WASHINGTON STATE DEC P1, 24 CERTIFICATE OF COMPETENCY FIRE SPRINKLER SYSTEMS i John Shakespeare i i 7566-0908-A*-H Level 1 Eclipse Fire Sprinklers, LLC ECLIPFS78/3DPP 11 /29/24 _1 Signature Date j EDMONDS RESIDENCE LOT- 4 DRAWN BY: CHECKED BY: 17907 - 240TH STREET SOUTHWEST, EDMONDS, WASHINGTON DATE: 28 OCT, 2024 SCALE: AS SPECIFIEI JOB# FIRE PROTECTION PLAN DRAWING SHEET: REV: 2OF2