Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
APPROVED PLN RESUB1 BLD2024-0551+Site_Plan+8.21.2024_10.49.49_AM+4454076
Al GENERAL INFORMATION GENERAL SITE PLAN NOTES PROPERTY OWNER: KEVIN AND CAROLYN REID ADDRESS: 326 SUNSET AVE 1. EXTERIOR LIGHTING SHALL BE SHIELDED AND DIRECTED AWAY FROM SURVEY DATUM: RESIDENTIALLY ZONED LOTS. (c) ON SITE PLAN PLAN 2. BUILDING SHALL BE PROVIDED WITH AN APPROVED ADDRESS IDENTIFICATION. THE ADDRESS IDENTIFICATION SHALL BE LEGIBLE AND (SEE SHEET C0.1 FOR ADDITIONAL INFORMATION) PLACED IN A POSITION THAT IS VISIBLE FROM THE STREET FRONTING THE DATUM: NAVD88 PROPERTY. ADDRESS IDENTIFICATION CHARACTERS SHALL CONTRAST PER WGS SURVEY DATA WITH THEIR BACKGROUND. ADDRESS NUMBERS SHALL BE ARABIC WAREHOUSE NUMBERS OR ALPHABETICAL LETTERS. EACH CHARACTER SHALL BE NOT DESIGNATION 1778 = CAD # LESS THAN 4 INCHES HIGH WITH A MINIMUM STROKE WIDTH OF 1/2 INCH. DB ID: 17606 3. PER ECDC 17.03.000 FENCES, FREESTANDING WALLS, BULKHEADS, SIGNS, DESCRIPTION: BRASS DISK IN CONCRETE AND SIMILAR STRUCTURES SHALL BE 3 FEET OR LESS IN HEIGHT ABOVE MONUMENT EXISTING OR FINISHED GRADE, WHICHEVER IS LOWER, WITHIN 10 FEET OF LOCATION: IN THE CENTERLINE OF SUSNET ANY STREET RIGHT-OF-WAY OR ACCESS EASEMENT AND 6 FEET OR LESS AVENUE DIRECTLY WEST OF IN HEIGHT ABOVE LOWEST ORIGINAL GRADE ANYWHERE ON THE SITE. HOUSE#210 ELEVATION: 37.5655 (LOCATED IN 2021) TREE PROTECTION NOTES EXISTING EASEMENTS: 1. ACCESS EASEMENT ALONG SOUTH PROPERTY LINE PROTECTION OF RETAINED TREES: RECORD NUMBER 8811020086 1. INSTALL TREE PROTECTION FENCING (TPF) PRIOR TO ANY SITE CLEARING OR DEMOLITION. PROPOSED EASEMENTS: 2. TPF SHALL BE 6-FOOT CHAIN LINK AFFIXED TO DRIVEN POSTS ON 1. PEDESTRIAN EASEMENT ALONG SUNSET AVE. TO BE MINIMUM 10-FOOT CENTERS. RECORDED PRIOR TO PERMIT ISSUANCE 3. SEE ATTACHED EXHIBIT FOR TPF LOCATION 2. UTILITY EASEMENT TO ALLOW STORM SEWER 4. ALL BRANCH PRUNING SHALL BE PERFORMED UNDER THE DIRECTION OF CONNECTION THROUGH ADJACENT PROPERTIES TO THE PROJECT ARBORIST, AND PERFORMED BY AN EXPERIENCED ISA THE NORTH. TO BE RECORDED PRIOR TO PERMIT CERTIFIED ARBORIST AND SHALL COMPLY WITH ANSI A-300 PART 1 (2017) ISSUANCE. STANDARDS AND ASSOCIATED ISA BMPS. CRITICAL AREAS: 5. ANY OTHER SOIL DISTURBANCE (IRRIGATION, LANDSCAPE INSTALLATION, LANDSCAPE LIGHTING, UTILITIES, ETC), INSIDE THE TPF SHALL REQUIRE 1. LANDSLIDE AND EROSION. SEE TECHNICAL REPORT APPROVAL FROM AN SDCI PLANNER, OR THE PROJECT ARBORIST. PREPARED BY FURR ENGINEERING SERVICES PLLC 2. SEISMIC HAZARD. SEE TECHNICAL REPORT PREPARED BY FURR ENGINEERING SERVICES PLLC TREE SCHEDULE SCALE: N/A 1. ON SITE ASSESSMENT HAS BEEN PERFORMED BY A REGISTERED DESIGN PROFESSIONAL AND NO SIGNIFICANT TREES WERE DISCOVERED ON THE PROPERTY. 2. TO COMPLY WITH ECDC 23.10.080, THREE TREES OF SIGNIFICANT SIZE AT MATURITY WILL BE PLANTED IN ASSOCIATION WITH THE PROPOSED DEVELOPMENT. _ IMPROVED SURFACE IN FRONT YARD SCALE: N/A TOTAL FRONT YARD AREA: 1320 SF TOTAL ALLOWED IMPROVED SURFACE: 660 SF TOTAL IMPROVED SURFACE IN FRONT YARD: 640 SF ZONE 1 (SIDEWALK): 119 SF ZONE 2 (ENTRY PATH): 90 SF ZONE 3 (CONC. BENCH & RETAINING WALLS): 116 SF ZONE 4 (CONC. PAVERS): 315 SF SITE PLAN LEGEND SS SS PROPERTY LINE / SETBACK LINE EXISTING CONTOUR LINE OF ROOF ABOVE EXISTING WOOD FENCE EXIST. SEWER LINE EXIST. STRUCTURE TO BE DEMOLISHED DECIDUOUS TREE, SYMBOL INDICATES EXTENT OF DRIPLINE UTILITY POLE EXISTING WATER METER PROPOSED BUILDING FOOTPRINT ROCKERY TREE ID EXISTING TO REMAIN / EXISTING TO BE REMOVED / NEW DIAMETER GENUS SPECIES REMARK PNW NATIVE TREE A NEW 1 2 ACER PALMATUM JAPANESE MAPLE NO TREE B NEW 1 111 ACER GLABRUM VAR. DOUGLASII DOUGLAS MAPLE YES TREE C NEW 1 111 ACER GLABRUM VAR. DOUGLASII DOUGLAS MAPLE YES TOTAL DIAMETER 4.5" zi ARCHITECTS 2126 Westlake Ave. Seattle, WA 98121 206.621.7150 tylerengle.com PROJECT TITLE JOB NUMBER REID 2303 326 SUNSET AVE N. EDMONDS WA, 98020 ISSUE / REVISIONS DATE PERMIT SET 06.06.2024 INTAKE CORRECTION 0 04.29.2024 PERMIT CORRECTIONS A2 08.19.2024 © 2023 TYLER ENGLE ARCHITECTS 1261 REGISTERED ARCHITECT / I TYLER CHASE ENGLE STATE OF WASHINGTON :RING DEDICATED APPROVAL STAMP SPACE APPROVED BY PLANNING RES U B Aug Aug 21 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-0551 DRAWING TITLE SITE PLAN DRAWN / CHECKED BY DRAWN BY: E. RUIVO CHECKED BY: E. LUND, T. ENGLE DATE 06.13.2024 SHEET NUMBER A0m1