FIR2025-0001_Fire_Alarm_Equipment_Specification_Sheets_1.3.2025_8.18.38_AM_4694892
EXISTING FACP Model 5204 Fire Alarm Control Panel and Optional Digital Communicator Silent Knight's 5204 is compact and easy to install and service, delivering features you'd expect to find in systems costing much more. The Silent Knight Model 5204 Fire Alarm Control Panel is a local fire evacuation control panel designed for applications requiring manual and automatic fire alarm as well as water flow and sprinkler supervisory service. Description The basic 5204 unit offers local fire alarm control for up to four zones and central station communications with the optional UL Listed Model 5205 Digital Communicator. The 5204 has 3 Amp power supply, 2- 1.5 Amp supervised notification circuits and supports both 2- and 4-wire smoke detectors. The 5204 includes an annunciator inside the cabinet for annunciation and operation. LEDs are visible without opening the cabinet. Operation keys include SILENCE, DIALER RESET, and DISPLAY TROUBLES. Remote annunciation is available through the optional Model 5230. This four -wire annunciator can perform the same operation as the main system annunciator and features English -language LCD display and programming capability. Features The 4 Class B can be converted to Class A using the Model 7181 Zone Converter. Fuseless design reduces service calls. Field selectable 24 or 12 VDC power supply. • 3 amp current output available for external devices. • Compatible with 2- and 4-wire smoke detectors as well as water flow and sounding devices. • Two 1.5 amp supervised notification circuits programmable for steady, pulsing, or supervisory • Auxiliary outputs of 1.5 amp at 12 or 24 VDC and 175 mA at 12VDC (only) • Smoke verification, pre -alarm delay and cross -zoning minimize false alarms. • Two general purpose relays (2.5A dry contact, Form C) • Optional plug-in UL Listed digital communicator (Model 5205) • Up/downloading (reduces installation time) • Programmable from on -board touchpad or optional remote annunciator (Model 5230) • Accu-Zone TPA diagnostics for on -site troubleshooting. Specifications Electrical Specifications: Primary AC: 120 VRMS @ 60 hz, 2.5A Total Accessory Load: 3A @ 12 or 24 VDC Standby: 120 mA Alarm: 400 mA Notification Circuits: Two Class B 1.5A @ 12 or 24 VDC. Programmable for steady, pulsing, temporal and supervisory for sprinkler system supervision. 5204 Auxiliary Outputs: 1.5A @ 12 or 24 VDC 175 mA @ 12VDC Mechanical Specifications: Dimensions: 14-7/8"W x 19-5/8"H x 4-1/4"D (37.8 x 49.8 x 10.6 cm) Color: Red Telephone Requirements: Type of Jack: RJ31X (2 required) Approvals: UL 864 NFPA 72 -Central Station Reporting -Local Protective Signaling System -Auxiliary Signaling System -Remote Signaling FCC Part 68 and Part 15 CSFM: 7165-0559:117 New York City: MEA 429-92-E SILENT KNIGHT by Honeywell Model 5204 Fire Alarm Control Panel and Optional Digital Communicator 2 Engineering Specifications The contractor shall provide a completely electrically supervised fire alarm control system. The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, alarm notification devices and visual annunciators. An optional digital communicator shall transmit fire alarm, trouble and supervisory signals to a central station. The controller shall be UL Listed for use under NFPA 72 standards. It shall provide power and control for four supervised detection zones, 2 supervised notification circuits, and, optionally, an approved plug-in digital communicator. The controller shall be Silent Knight 5204 or equivalent. There shall be four Class B detection zones. Products of combustion detection may be either 2- or 4-wire and shall be cross - listed by UL for use on the system. The detection zones shall be programmable to (1) be cross zones so that two adjacent detectors must sense products of combustion, (2) automatically reset a detector to verify that smoke exists, and (3) see a single detector in alarmflbefore an alarm is sounded, and, optionally, transmit a signal to the central station. There shall be two 1.5 amp supervised alarm notification circuits. They shall cause the bells/horns to ring steady/pulsing/ temporal through the premises until reset or silenced. The control shall be equipped with two auxiliary relays that shall be programmable to operate on (1) alarm, (2) trouble, (3) supervisory, (4) supervisory trouble and (5) system trouble. The relays shall maintain contact until cleared. The control shall have one on -board touchpad and shall support 3 remote annunciators. LEDs shall augment the display to clarify the system status to an operator. An integral touchpad shall be provided to operate, set up and interrogate the system. The optional plug-in digital communicator shall be UL Listed for use under NFPA 72 standards. It shall have the capability to supervise two telephone lines, seize the phone line and send the alarm signal on one or both lines without additional equipment. It shall be able to communicate to a central station in SIA, SK FSK (4/2), SK4/2 tone burst, SK 3/1, SESCOA 3/1, Radionics BFSK. The communicator shall sound a local trouble signal if the telephone service is interrupted for longer than 45 seconds and it shall transmit a signal indicating restoral of phone service. The optional digital communicator shall have the ability to send a test signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night by setting a program within the communicator. The alarm signals transmitted to the central station shall indicate which zones are in alarm and which zones are in trouble. Restoral from an alarm shall also be transmitted by zone. Optional Accessories 5230 Remote Annunciator Performs all the same functions as the on -board annunciator and features an LCD English -language display and backlighting. 5205 Digital Communicator Performs all the same functions as the on -board annunciator and features LCD English -language display and backlighting. 5211 Auxiliary Relay Enables ground start phone lines 4180 Status Display Module Provides 16 outputs to give alarm and trouble conditions by zone. Can be used to drive LED or graphic annunciators. Non - supervised. 7181 Fire Zone Converter Converts Class A zones to Class B and vice versa. SILENT KNIGHT by Honeywell 7550 Meridian Circle, Maple Grove, MN 55369-4927 800-446-6444 or in Minnesota 612-493-6435 FAX: 612-493-6475 World Wide Web: http://www.silentknight.com 5220 Direct Connect Module Used for city box and polarity reversing direct wire applications. 5541 Downloading Software and 5530 Modem For remote programming of 5204 and other Silent Knight products using an IBM PC or compatible computer. MADE IN AMERICA FORM# 350778 Rev. B, 02/04 Copyright © 2004 Silent Knight NEW STROBE ONLY Commander Series Selectable Candela Evacuation Signals Applications The GCS/GCC Series is a ceiling mount strobe or horn/strobe combination that offers dependable audible and visual alarms and the lowest current consumption. The GCS/GCC offers tamperproof field selectable candela options of 15, 30, 75, 95, 115 and 150 candela. The GCC horn offers a continuous or synchable temporal three in 2400Hz and mechanical tone. All tones are easy for the professional to change in the field by using switches. The models are shipped from the factory in the temporal three alarm mode. The GC Series has a very minimal operating current and has a minimum flash rate of 1 Hz regardless of input voltage. The Commander4 Series comes standard with the 4" mounting plate which incorporates the popular Super -Slide° feature that allows the installer to easily test for supervision. The product also features a locking mechanism which secures the product to the bracket without any screws showing. The Commander4 also features the patented Checkmate° - Instant Voltage Verification feature which allows the installer to check the voltage drop draw without removing the signal. The GC Series appliances are ANSI/UL 464 and ANSI/UL 1971 listed for use with fire protective systems and are warranted for three years from the date of purchase. Standard Features • Nominal voltage 24VDC • Tamperproof field selectable candela options of 15, 30, 75, 95,115 & 150 • Super -Slide° Bracket - Ease of Supervision Testing • Checkmate° - Instant Voltage Verification • Unit Dimensions: 6" (15.24 cm) x 2.6" (6.604 cm) • Synchronize strobe and/or horn with Gentex AVSM Control Module • Prewire entire system, install mounting bracket, then install signals • Documented lower installation and operating costs • Input Terminals 12 to 18 AWG • Switch Selection for High or Low dBA • Switch Selection for 2400Hz or Mechanical Tone • Switch Selection for Continuous or Temporal 3 • Tamperproof re-entrant grill • Surface mount with the GCSB (Gentex Ceiling Surface Mount Box) GCS/GCC 24VDC SERIES -- T �Illl"' Product Listings SIGNALING V FM APPROVED LISTED • ANSI/UL 464 and ANSI/UL 1971 Listed • FM Approved • CSFM: 7135-0569:122 (GCC) 7125-0569:123 (GCS) • MEA: 285-91-E Patents • 7,375,617 May 20, 2008 Product Compliance • NFPA 72 • Americans with Disabilities Act (ADA) • IBC/IFC/IRC • City & State ordinances/Laws/Regulations • Quality Management System is certified to: ISO 9001:2008 • Silence audible while visual appliance will remain flashing (for use in accepted jurisdictions) • Faceplate available in red or off-white ■ EPYRIA MEMBER GCS Series 24 Volt Ceiling Mount Selectable Strobe Model Number Part Number Nominal Voltage Candela GCS24CR 904-1213-002 24VDC 15, 30, 75, 95, 115, 150 GCS24PCR 1 904-1214-002 1 24VDC 15, 30, 75, 95, 115, 150 6CS24PCW 1 904-1216-002 1 24VDC 15, 30, 75, 95, 115, 150 GCC Series 24 Volt Ceiling Mount Selectable Horn/Strobe Model Number Part Number Nominal Voltage Candela Reverberant dBA @ 1Oft. per ANSI/UL 464 In Anechoic Room dBA @ 10ft. GCC24CR 904-1209-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24PCR 904-1210-002 24VDC 15, 30, 75, 95, 115, 150 81-86 90 GCC24CW 904-1211-002 24VDC 15, 30, 75, 95, 115,150 81-86 90 GCC24PCW 1 904-1212-002 1 24VDC 1 15, 30, 75, 95, 115, 150 1 81-86 1 90 Model Designations: C = Ceiling Mount R = Red Faceplate W = White Faceplate All units are available in plain (no lettering). Plain units are non -returnable. GC24 Product Strobe Current Ratings (mA) Candela 15cd 30cd 75cd 95cd 115cd 150cd 24VDC (16-33 Volts) 24VDC 72mA 101 mA 167nnA 200mA 214mA 286mA UL Max' 120mA 120mA 200mA 220mA 290mA 321 mA GCC24 Product Horn Decibel and Current Ratings (mA) Horn Mode Minimum dBA @ 10ft. per ANSI/UL 464 (HIGH) Minimum dBA @ 10ft. per ANSI/UL 464 (LOW) Regulated 24VDC Max. Operating @ High Setting (mA) Temp 3 2400Hz 83 75 23 emp 3 Mechanical 81 73* 22 Continuous 2400Hz 86 78 23 Continuous Mechanical 84 76 22 NOTES: • Operating temperature: 32°to 120°F (0° to 49°C). The GC Series is not listed for outdoor use. • The sound output for the temporal 3 tone is rated lower since the time the horn is off is averaged into the sound output rating. While the horn is producing a tone in the temporal 3 mode its sound pressure is the same as the continuous mode. • For nominal and peak current across UL regulated voltage range for filtered DC power and unfiltered (FWR [Full Wave Rectified]) power, see installation manual. • Gentex does not recommend using a coded or pulsing signaling circuit with any of our strobe products (see Technical Bulletin Number 014). Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode). RMS current ratings are per UL average RMS method. UL max current rating is the maximum RMS current within the listed voltage range (16-33VDC for 24VDC units). For strobes the UL max current is usually at the minimum listed voltage (16VDC for 24VDC units). For audibles the max current is usually at the maximum listed voltage. For unfiltered FWR ratings, see installation manual. Mounting Super -Slide° 1. SUDE ONTO BRACKET Checkmate° Instant Voltage Verification The access holes are provided in the back of the terminal block to allow the voltage to be measured directly without removing the device. Typically this would be done at the end of the line to confirm design criteria. Most measurements will be taken using the S+ and S- locations although access is provided to other locations. NOTICE: CARE SHOULD BE TAKENTO NOT SHORT THE TEST PROBES. 1 3. SNAP COVER OVER ASSEMBLY Switch Locations GCS/GCC 24VDC SERI ES Conventional GC Series Wiring Diagrams NOTES: • All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits. However, use of ft Gentex AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. See Technical Bulletin 014 for additional information. • FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (551-0031) AND/OR AVSM CONTROL MODULE MANUAL (550-0284) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://www.gentex.com OR CALL GENTEX CORPORATION AT 1-800-436-8391. Architect & Engineering Specifications The visible and audible/visible signal shall be Gentex model GCS or GCC or approved equal and shall be listed by Underwriters Laboratories Inc. perANSI/UL 1971 for the GCS and ANSI/UL 464 for the GCC. The notification appliance shall also be listed with the California State Fire Marshal (CSFM) and the Bureau of Standards and Appeals (NYC). The notification appliance (combination audible/visible units and audible units only) shall produce a peak sound output of 90dBA or greater as measured at 24VDC in an anechoic chamber. The signaling appliance shall also have the capability to silence the audible signal while leaving the visible signal energized with the use of a single pair of power wires. Additionally, the user shall be able to select either continuous or temporal tone output with the temporal signal having the ability to be synchronized. The audible/visible and visible signaling appliance shall also maintain a minimum flash rate of 1 Hz or up to 2Hz regardless of power input voltage. The appliance shall have an operating current of 72mA or less at 24VDC for the 15 candela strobe circuit. The appliance shall be polarized to allow for electrical supervision of the system wiring. The unit shall be provided with a mounting bracket with terminals with barriers for input/output wiring and be able to mount to a single gang or double gang box or double workbox with the use of an adapter plate. The unit shall have an input voltage range of 16-33 volts with either direct current or full wave rectified power. The appliance shall be capable of test supervision without disconnecting wires, verify voltage without removing unit and be capable of mounting to a surface back box. 24 units per carton 29 pounds per carton Important Notice: 551-0051-06 G E N T E X These materials have been prepared Gentex Corporation Gentex") for informational purposes only, are necessarily summary, and aremnot not purported to serve as legall advice and should not be used as such. CORPORATION Gentex makes no representations and warranties, express or implied, that these materials are complete and accurate, up-to-date, or in compliance with all relevant local, state and federal laws, regulations and rules. The materials do not address all legal considerations as there is inevitable uncertainty regarding Fire Protection Products Grou • www.gentex.com interpretation of laws, regulations and rules and the application of such laws, regulations and rules to p g particular fact patterns. Each penson's activities can differently affect the obligations that exist under 10985 Chicago Drive • Zeeland, Michigan 49464 applicable laws, regulations or rules. Therefore, these materials shorld be used only for informational purposes and should not be used as a substitute for seeking professional legal advice. Genbx will not be 616.392.7195 • 1.800.436.8391 • 616.392.4219 Fax responsible for any action or failure to act in reliance upon the information contained in this material. Gentex Corporation reserves the right to make changes to the product data sheet at their discretion.