Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
FIR2025-0004_Fire_Alarm_Equipment_Specification_Sheets_1.8.2025_11.55.08_AM_4702063
Honeywell SILENT' I MGHT 6700 Addressable Fire Alarm Control Panel The 6700 is an addressable fire alarm control panel (FACP) that can be configured to achieve an overall point capacity of up to 100 points. It has one built-in signaling line circuit (SLC), which can support 50 System Sensor' (SK) sensors and 50 SK modules or 50 Hochiki° (SD) devices per loop. A common communications and annunciation link allows up to 17 panels to be connected via copper or fiber optic cable. A designated panel is configured as the communicator for all panels in the link for convenient single -point communications. It also has a built-in, dual - line POTs and IP communicator and optional cellular side -cars. The 6700 system can be enhanced by adding modules such as the 6860 remote annunciator which also has four programmable function buttons to help automate tasks and reduce time spent at the panel. SWIFT° wireless compatibility provides options for wireless detection through a Class A mesh network. It is ideal for hard - to -wire locations, buildings where newwiring is not allowed, or to provide an easy install fire system for new construction projects. SWIFT devices can be combined with other hard -wired 6700 compatible devices. SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. The 6700 also has Form C trouble relay, and two programmable Form C relays, along with powerful features such as drift compensation, pre - trouble maintenance alert, a built-in sensor test to complywith NFPA 72 calibration testing requirements, and calibration trouble alert. FEATURES & BENEFITS • Capable of providing up to 100 points to satisfy smaller installation needs • Connect up to 17 panels on one site with convenient single - point access using the SK-NIC Network Interface Card. Connected panels can have mixed compatible FACP models. • Convenient field-upgradeable firmware • Integrated dual path IP and POTs communications and optional cellular side -cars for reliable backup • 6860 annunciator with a 4 x 40 large display, and 4 programmable function buttons. Free -up time spent at the panel. Program them for simple or complex tasks. • Built-in USB interface for convenient and quick programming 6700 It supports a variety of devices, including the 6860, 5860, and 6855 remote annunciators, 5824 serial parallel printer interface module (for printing system reports), the 5496 NAC expander, 5895XL power module, and SK or SD devices. • Programmable date setting for automatic and convenient Daylight Saving Time changes • Built-in dual phone line and digital alarm communicator/ transmitter (DACT) for additional communication options • 125 software zones and 125 output groups for flexible design options 6700 Product Information SIGNAL LINE CIRCUIT (SLC) The 6700 SLC loops support multiple device types, maintenance alerts, and a built-in sensortestto complywith NFPA 72 calibration testing requirements. INDICATOR LIGHTS • General Alarm (Red): Flashes if in alarm; solid when alarm is silenced • Supervisory (Yellow): Flashes if a supervisory condition exists; solid when supervisory is silenced • System Trouble (Yellow): Flashes if a trouble condition exists; solid when trouble is silenced • System Silenced (Yellow): On when an alarm, trouble or supervisory condition has been silenced but not yet cleared • System Power (Green): Flashes forAC failure; solid when power systems are normal USERINTERFACE The 6700 built-in 4 x 20 annunciator with 80 character LCD display and large easy -to -use tactile touchpad can be used for system operation, programming and maintenance. It has five LEDs for alarm, supervisory, system trouble, system silenced and system power. System operations include silencing alarms and troubles, resetting alarms and the display of alarm troubles and memory. The system's non-volatile event history buffer stores 1,000 events for viewing from the built- in or remote annunciator. System operations can be initiated with a mechanical firefighter's key or a valid 4- to 7-digit operator's code. 6700 KEYPAD PROGRAMMING The 6700 system offers several options to simplify and speed-up programming. JumpStart° autoprogramming minimizes programming required to start new system. The built-in keypad, or the 6860, 5860 or 6855 remote annunciators give you on -site access to current system programming. You can also program the system using the Honeywell Fire Software Suite (HFSS), which is Windows° based. SOFTWARE TOOLS SKST: Silent Knight Selection Tool provides the installer or design architect with a Windows° software system configuration tool to create a detailed Bill of Material (BOM) and battery calculations. HFSS: Honeywell Fire Software Suite provides communication and panel programming, detector status, event history and additional data. Requires a Windows -based computer. ADDITIONAL INFORMATION Twisted -unshielded pair wire is recommended. The 6700 also has 13 preset notification cadence patterns (including ANSI 3.41). NFPA 13, NFPA 15, NFPA 16, NFPA 70, NFPA 72: Central station; remote Signaling; Local Protective Signaling Systems; Auxiliary Protected Premises Unit; Water Deluge releasing service. Suitable for automatic, manual, waterflow, sprinkler supervisory (DACT non -coded) signaling services. • UL Listed: S2766 • CSFM 7165-0559:050 • FDNY COA# 6250 • Seismic (CA) (pending) ORDERING INFORMATION 6100: Addressable Fire Alarm Control Panel. (Red cabinet) [d•IV, I].d1-]1441:I2U1:[dh111i67:19 6860:4x40 LCD remote fire annunciator (4 lines and up to 160 characters) per system; four programmable buttons 5860: 4x20 LCD remote fire annunciator. 5860 is gray; 5860R is red 6855:4x20 LCD remote fire annunciator 5865-3 or 5865-4: LED annunciators can display up to 30 LEDs (15 red and 15 yellow). The 5865-4 has key switches for silence and reset, and a system trouble LED. 5880: The 5880 LED / 10 module has 40 programmable LED outputs and eight supervised dry contact inputs which are useful for custom applications. You can use up to eight 5880 modules on one control panel for maximum flexibility. Its compact size allows mounting inside the annunciator, or in an accessory cabinet. 6700 COMPATIBLE DEVICES AND ACCESSORIES See the data sheets listed below for a complete listing of the SK, SD or SWIFT devices. 53623: SK Devices Data Sheet 53624: SD Devices Data Sheet 350614, 350616 & 350618: SWIFT wireless devices For a complete and current listing of compatible devices and accessories go to www.sitentknight.com Important: You cannot mix SK and SD devices in the same fire alarm system. SK COMPATIBLE ADDRESSABLE DEVICES SK-ACCLIMATE: Multi criteria photoelectric smoke detector with thermal 135°F fixed temperture SK-BEAM: Reflected beam smoke detector without test feature SK-BEAM-T.- Reflected beam smoke detector with test feature SK-CONTROL: Supervised control module SK-CONTROL-6: Six circuit supervised control module SK-DUCT: Photoelectric duct smoke detector with extended airspeed range SK-FIRE-CO: Four criteria fire and carbon monoxide detector SK-HEAT: Fixed thermal detector (135°F) SK-HEAT-ROR: Fixed rate of rise detector (135°F) SK-HEAT-HT: Fixed high temperature thermal detector (190°F) SK-ISO: Fault isolator module SK-MINIMON: Mini monitor module SK-MONITOR: Monitor module SK-MONITOR-2: Dual input monitor module SK-MON-10: 10 input monitor module SK-PHOTO: Photoelectric smoke detector SK-PHOTO-T. Photoelectric smoke detector with thermal (1350F fixed temperture) SK-PHOTOR: Photoelectric detector with remote test capability SK-PULL-SA: Addressable single action pull station SK-PULL-DA: Addressable dual action pull station SK-RELAY: Addressable relay module SK-RELAY-6: Addressable Six relay control module SK-RELAYMON-2: Addressable Dual relay/ monitor module SK-ZONE: Addressable zone interface module SK-ZONE-6: Six zone interface module B21OLP: 6" mounting base 13501:4" Flangeless mounting base B20OS: Intelligent sounder base B20OS-LF: Low -frequency intelligent sounderbase B224RB: Relay base B224B1: Isolator base SD COMPATIBLE ADDRESSABLE DEVICES SD505-6AB: Addressable 6" base SD505-61B: Addressable 6" short circuit isolator base SD505-6RB: Addressable 6" relay base SD505-6SB: Addressable 6" sounder base SD500-AIM: Addressable input module (switch input) SD500-ANM: Addressable notification module SD500-ARM: Addressable relay module SD505-DTS-K: Remote test switch and LED indicator for theSD505-DUCTR SD505-DUCT: Addressable Duct Smoke Detector. SD505-DUCTR:Addressable Duct Detector housing with relay base. SD505-HEAT: Absolute temperature heat detector. Trip point range from 1350E-150OF(OOC-370C). SD500-LIM: Addressable Line isolator module SD500-MIM: Addressable Mini input monitor module (switch input) SD505-PHOTO: Photoelectric smoke detector SD500-PS/-PSDA: Addressable Single or dual action pull station SD500-SDM: Addressable smoke detector module AUDIBLE/VISIBLE DEVICES These AV devices are all 2-wire. Color: "R" indicates red; "W" denotes white. For a complete listing of Silent Knight AV devices go to www.sitentknight.com. CHSRL/CHSWL: Wall chime/strobe CHSCRL/CHSCWL: Ceiling chime/strobe CHRL/CHWL: Wall chime HRL/HWL: Wall horn P2RL/P2WL: Wall horn/strobe PC2RL/PC2WL: Ceiling horn/strobe SRL/SWL: Wall strobe SCRL/SCWL: Ceiling strobe SPSCRL/SPSCWL: Ceiling speaker/strobe SPSRL/SPSWL: Wall speaker/strobe SPRL/SPWL: Wall speaker SPCRL/SPCWL: Ceiling speaker SWIFT WIRELESS DEVICES SWIFT is only compatible with System Sensor (SK) devices. It is not compatible with Hochiki (SD) devices. WSK-WGI: Wireless Gateway WSK-PHOTO: Wireless Photoelectric smoke detector WSK-PHOTO-T. Wireless Multi -criteria photoelectric smoke detector with thermal detection (135°F fixed temperture) and B51OW 4" base WSK-HEAT: Wireless Heat, (135°Ffixed temperture) and B51OW 4" base WSK-HEAT-ROR: Wireless heat, POP (135°F fixed temperture) and B51OW 4" base WSK-MONITOR: Wireless monitor module WSK-RELAY: Wireless relay module W-USB: SWIFTTools USB transceiver used for communication with SWIFT devices SBUS ACCESSORIES 5496: A 6 amp notification power expander with four power -limited notification appliance circuit outputs. 5883: Relay interface. Provides 10 Form C relays. 5824: Serial/Parallel printer interface module for printer connection. 5895XL: Power supply with six Flexput' circuits, and two Form C relays. Max. 16 per system. 5815RMK: Remote mounting kit. Dimensions 10 3/8"W x 10-3/16"H x 3"D COMMUNICATION OPTIONS CELL-CAB-SK: Cellular communicator, metal enclosure with lock/key* CELL -MOD: Cellular communicator, plastic enclosure* *Sole path, powered by panel. IPGSM-4G: Dual path fire alarm communicator, cellular and/or IP (primary or backup, selectable) SK-I13-2: Remote reporting via the Internet. Requires a VisorAlarm° receiver at the central station MISC. ACCESSORIES SK-NIC: Network Interface Card. Provides a common communications link forthe 6700 SK-NIC-KIT: Installation Accessory Kit SK-FML: Fiber -Optic Multi Mode, transmitter and receiver SK-FSL: Fiber -Optic Single Mode RBB: Remote battery box accessory cabinet for batteries that are too large to fit in the FACP cabinet. Dimensions: 16" W x 10" H x 6" D (406mm W x 254mm H x 152mm D). SK-SCK: Seismic Compliance Kit used to securely fasten batteries to the fire panel. 6700 Technical Specifications PHYSICAL NOTIFICATION APPLIANCE CIRCUITS (NACs) For a complete listing of all Overall Dimensions: 12.71" W x 15.12" H x 3.33" D Two programmable circuits which can be compliance approvals and Weight:l5lbs. individual) as: programmed y certifications, please visit www.silentknight.com. Color: Red NACs: 2.5A C 27.4VDC per circuit, power -limited (with a panel maximum current of 2.5A) Microsoft, Windows, and ENVIRONMENTAL Auxiliary Power Circuits: 2.5A @ 27.4VDC per the Windows Logo are 0 0 o Operating Temperature: 32 F to 120 F (0 C to circuit, power -limited p registered trademarks or trademarks of 49°C) Microsoft Corporation. Humidity: 0 to 93% relative humidity (non- Supports Class B (Style 4) and Class A (Style 6 or 7) condensing) configuration for the SLC Silent Knight°, Honeywell' and SWIFT' are registered trademarks of Honeywell ELECTRICAL WIRING: See the product manual for wiring details International, Inc. 6700 Primary AC: 120 VAC @ 60 Hz, 1.5ATotal Accessory Load: 2.5A C 27.4 VDC power -limited This document is not Standby Current: 165mA S intended to be used for installation purposes. We Alarm Current: 310mA tryto keep our product Battery Charging Capacity: 7 to 35AH information up -to Battery Size: 7AH max. allowed in control panel date and accurate. cannot cover all specific cabinet. Larger capacity batteries can be housed in applications or anticipate RBB accessory cabinet.. all requirements. All specifications are subject to change without notice. For Technical Support, ca11800-446-6444. For more information Learn more about Honeywell Silent Knight and other products byvisiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road N o rthfo rd, CT 06472 3516071 A 111/17 H o n eywe I I 800-328-0103 © 2017 Honeywell International Inc. Honeywell SILENT' I MGHT SK-PHOTO-W Series Intelligent Plug -In Photoelectric Smoke Detector Honeywell Silent Knight SK-PHOTO-W Series plug-in smoke detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. The SK-PHOTO-W Series detector sensitivity can be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel. Point ID capability allows each detector's address to be set with rotary, decimal address switches, providing exact detector location for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the SK-PHOTO-T-W. The SK-PHOTO-R-W is a remote test capable detector for use with DNR Series duct detector housings. FEATURES & BENEFITS • New modern profile for improved aesthetics • Stable communication technique with noise immunity • Low standby current • Two -wire SLC connection • Optional remote, single- gang LED accessory • Dual LED design provides 360'viewing angle • Remote test feature from the panel • Built-in functional test switch activated by external magnet • Built-in tamper - resistant feature • Sealed against back pressure • Expanded color options • SEMS screws for wiring of the separate base SK-PHOTO-W • Optional relay, isolator, and sounder bases • Plugs into separate base for ease of installation and maintenance DETECTOR SPACING AND APPLICATIONS Honeywell recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet (9m). For specific information regarding detector spacing, placement, and special applications refer to NFPA72. System Smoke Detector Application Guide, documentA05-1003, is available at systemsensor.com INSTALLATION The SK-PHOTO-W Series plug-in detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector. Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. • When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. ORDERING INFORMATION SK-PHOTO-W: Photoelectric smoke detector. white. SK-PHOTO-R-W: Photoelectric smoke detector, remote test capable, for use with DNR(W) duct smoke detectors, white. SK-PHOTO-T-W: Photoelectric smoke detector with thermal sensing, white. INTELLIGENT BASES B300-6: White, standard flanged low -profile mounting base. B300-6-BP: Bulk pack of 3300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV:Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory, plug-in System Sensor isolator detector base. ACCESSORIES CK300: Color Kit (includes cover and trim ring), white,10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black,10-Pack. M02-04-01: Detector test magnet. M02-09-00:Telescoping test magnet. RA10OZ: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6. white. TR300-IV: Replacementtrimring for B300-6-IV, ivory. SK-PHOTO-W Series Detector Technical Specifications PHYSICAL COMPATIBILITY For a complete listing of all compliance approvals and Height: 2.0" (51mm) installed in B300-6 base The SK-PHOTO-W series detectors are certifications, please visit Diameter: 6.2" (156mm) installed in B300-6 compatible with the following Honeywell Silent www.sitentknight.com. base 4.1" (104 mm) installed in B501 base Knight fire alarm control panels: Microsoft, Windows, and the Windows Logo are Weight: 3.4 oz (95 g) 6820: Addressable fire alarm control panel registered trademarks 6820EVS: Addressable fire alarm control panel or trademarks of Microsoft Corporation. ENVIRONMENTAL with an emergency voice system. Operating Temperature range: Silent Knight°, System 6808: Addressable fire alarm control panel Sensor' and Honeywell' Photo: 320F to 122°F (0°C to 50°C) are registered 6700: Addressable fire alarm control panel trademarks of Honeywell Photo with Thermal: 320Fto 100OF (0°C to International, Inc. 5700: Addressable fire alarm control panel 38°C) 5808: Addressable fire alarm control panel This document is not UL listed Velocity range: Photo/Photo with intended to be used for Thermal: 0 to 4,000 fpm (0 to 20 m/sec) 5820XL: Addressable fire alarm control panel installation purposes. We tryto keep our product (suitable for installation in ducts) 5820XL-EVS: Addressable fire alarm control information up -to Humidity: 10% to 93% non -condensing panel with an emergency voices stem p g y y date and accurate. We cannot cover all specific applications or anticipate Thermal Ratings: Fixed Temperature Set point: AGENCY LISTINGS AND APPROVALS all requirements. All 1350F (570C) For exact certification listings for each model, specifications are subject please reference the respective agency Web site. to change without notice. ELECTRICAL RATINGS UL listed: S6173 For Technical Support, Voltage Range:15 to 32VDC peak FM approved caIt 800-446-6444. CS FM: 7272-0559:0523 Operating Current C 24VDC: 20%tA (one communication every 5 seconds with green LED blink on communication) Maximum Current:4.5mA @ 24VDC (one communication every 5 seconds with amber LED solid on). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford, CT 06472 Doc 3516341 Rev A 104/18 r SILENT 800-328-0103 © 2018 Honeywell International Inc. L3 WGHT Honeywell SILENT' I MGHT SK-HEAT-W Series Intelligent Thermal (Heat) Detector Honeywell Silent Knight SK-HEAT-W Series intelligent thermal detectors are designed for both performance and aesthetics. A new modern, sleek, contemporary design and advanced thermaltechnologies make the SK-HEAT-W Series ideal for both system operation and building design. The point ID address, set using rotary decimal switches, provide specific detector locations. The series includes a 135°F/57°C fixed temperature, rate -of -rise and a 1901F/881C fixed high -temperature detectors. These thermal detectors provide effective, intelligent property protection in a variety of applications. FEATURES & BENEFITS • Sleek and stylish contemporary design • Advanced thermal technology for fast response • Fixed temperature model (SK-HEAT-W) factory preset to 1350F(570C) • Rate -of -rise model (SK-H EAT-W-ROR), 150F (8.3°C) per minute • High temperature model (SK-HEAT- W-HT) factory preset to 1901F(8810 • Addressable by device • Two -wire SLC connection • Visible LEDs "blink" every time the unit is addressed • Built-in tamper - resistant feature • 3600-field viewing angle of the visual alarm indicators (two bi-color LEDs). LEDs blink green in Normal condition and turn on steady red in Alarm. • Integral communications and built-in device -type identification • Remote test feature from the panel SK-HEAT-W • Built-in functional test switch activated by external magnet • Walk test with address display (an address of 121 will blinkthe detector LED 12- (pause)-1) • Low standby current • Designed for directsurface or electrical box mounting • Sealed against back pressure • Plugs into separate base for ease of installation and maintenance • SEMS screws for wiring of the separate base • Optional remote, single- gang LED accessory APPLICATIONS INTELLIGENT BASES ACCESSORIES Use thermal detectors for protection of property. For further information, refer to manual 156-6541, Applications Manual for System Smoke Detectors, which provides detailed information on detector spacing, placement, zoning, wiring, and special applications INSTALLATION The SK-HEAT-W Series plug-in intelligent thermal detectors use a separate base to simplify installation, service, and maintenance. Installation instructions are shipped with each detector Mount base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. NOTE: • Because of the inherent supervision provided by the SLC loop, end -of -line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. • When using relay or sounder bases, consult the installation sheet for device limitations between isolator modules and isolator bases. NOTE: Detectors must be mounted to one of the Intelligent Bases listed below. ORDERING INFORMATION SK-HEAT-W: Thermal heat detector, 1351F fixed, white. SK-HEAT-ROR-W: Thermal heat detector, 1351 F rate of rise, white. SK-HEAT-HT-W: Thermal heat detector, 190°F high temp, white. B300-6: White, standard flanged low -profile mounting base. B300-6-BP: Bulk pack of 3300-6, package contains 10. B300-6-IV: Ivory, standard flanged low -profile mounting base. B30OA-6-IV: Ivory, standard flanged low -profile mounting base. UL listed. B501-WHITE: White, standard European flangeless mounting base. UL listed. B501-BL: Black, standard European flangeless mounting base. UL listed. B501-IV: Ivory, standard European flangeless mounting base. UL listed. B20OS-WH: White, Intelligent, programmable sounder base. B20OS-IV: Ivory, Intelligent, programmable sounder base. B200SR-WH: White, Intelligent sounder base for retrofit applications. B200SR-IV:Ivory, Intelligent sounder base for retrofit applications. B20OS-LF-WH: White, Low Frequency Intelligent, programmable sounder base. B20OS-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. B200SR-LF-WH: White, Low Frequency Intelligent sounder base for retrofit applications. B200SR-LF-IV: Ivory, Low Frequency Intelligent sounder base for retrofit applications. B224RB-WH: White, plug-in System Sensor relay base. B224RB-IV: Ivory, plug-in System Sensor relay base. B224BI-WH: White, plug-in System Sensor isolator detector base. B224BI-IV: Ivory, plug-in System Sensor isolator detector base. CK300: Color Kit (includes cover and trim ring), white,10-Pack. CK300-IV: Color Kit (includes cover and trim ring), ivory, 10-Pack. CK300-BL: Color Kit (includes cover and trim ring), black,10-Pack. M02-04-01: Detector test magnet. M02-09-00:Telescoping test magnet. RA10OZ: Remote LED annunciator SMB600: Surface Mounting Kit (flanged). TR300: Replacement trim ring for B300-6. white. TR300-IV: Replacementtrimring for B300-6-IV, ivory.. SK-HEAT-W Series Detector Technical Specifications PHYSICAL Height: 2.0" (51mm) installed in B300-6 base Diameter: 6.2" (156mm) installed in B300-6 base 4.1" (104 mm) installed in B501 base Weight: 3.4 oz (95 g) 4:1y/ I:Z•]:1IV, 142 Y L1 1111 Operating Temperature range: Heat -Fixed temperature: -4°F to 100°F (-20°C to 38°C) Heat -Rate of Rise (ROR): -4°F to 100°F (-20°C to 38°C) Heat -High Temperature: -4°F to 150°F (-20°C to 66°C) Humidity: 10%to 93% non -condensing Thermal Ratings: Fixed Temperature Set point: 1350F (570C) Rate -of -Rise Detection: 151F/min. (8.30C/min High Temperature Heat:190°F (881C)Electrical Ratings ELECTRICAL RATINGS Voltage Range:15 to 32VDC peak Standby current (max. avg.): 200uA C 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.):4.5mA @ 24 VDC ("ON"). For more information Learn more about Honeywell Silent Knight and other products by visiting www.sitentknight.com Honeywell Silent Knight 12 Clintonville Road Northford, CT 06472 800-328-0103 COMPATIBILITY The SK-HEAT-W series detectors are compatible with the following Honeywell Silent Knight fire alarm control panels: 6820: Addressable fire alarm control panel 6820EVS: Addressable fire alarm control panel with an emergency voice system. 6808: Addressable fire alarm control panel 6700: Addressable fire alarm control panel 5700: Addressable fire alarm control panel 5808: Addressable fire alarm control panel 5820XL: Addressable fire alarm control panel 5820XL-EVS: Addressable fire alarm control panel with an emergency voice system AGENCY LISTINGS AND APPROVALS For exact certification listings for each model, please reference the respective agency Web site. UL listed: S2101 FM Approved CSFM:7270-0559:0511 Doc 351637 1 Rev A 104/18 © 2018 Honeywell International Inc. For a complete listing of all compliance approvals and certifications, please visit www.sitentknight.com. Microsoft, Windows, and the Windows Logo are registered trademarks or trademarks of Microsoft Corporation. Silent Knight°, System Sensor' and Honeywell' are registered trademarks of Honeywell International, Inc. This document is not intended to be used for installation purposes. We tryto keep our product information up -to date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For Technical Support, call 800-446-6444. Honeywell SILENT' IQVIGHT