APPROVED FIR2024-0124+Fire_Alarm_Plan+12.23.2024_11.42.22_AM+4684215FIRE ALARM - SWICKARD TOYOTA SHEET INDEX SHEET # DESCRIPTION REV 1 REV 2 FA0.01 GENERAL INFORMATION, NOTES, SCOPE, ETC.. FA1.01 FIRE ALARM -- PERTINENT MAIN LEVEL VICINITY MAP & BUILDING INFO 208th St. Sw 208th St. SW 270th St. SW f :E f f 212th St. SW 212th St. SW zucn St. sw 21300 H igh ay 99 3 3 a } L L w � r \yin st s;• a 1 v n � 5wedrsh dm Olds 216th St. SW 16th St. SW 2160 S, Cam us �C P OWNER: SC EDMONDS RE LLC, GLADSTONE, OR OCCUPANCY & USE (THIS TI): USE: AUTO SALES/SERVICE PROJECT SITE TYPE: B,S SPRINKLED: YES -FULLY PARCEL/TAX ID: 965703001 CODES: CITY OF EDMONDS MUNICIPAL CODE IFC (2021ed), NFPA72 (2022ed) WAC 51-54A-0907 PROJECT SCOPE & INFORMATION PROJECT SCOPE/DESCRIPTION: REPLACE EXISTING FIRE ALARM PANEL DUE TO FAILURE. REPLACE EXISTING AREA & ELEVATOR RECALL SMOKE DETECTION AND REPLACE MODULES FOR COMPLIANCE. FACILITY HAS FULL OCCUPANT NOTIFICATION EXISTING, AS PREVIOUSLY APPROVED AS PER BLD2017-1326. THE REQUIREMENTS OF ADOPTED CODE AT THE TIME OF ORIGINAL INSTALLATION AND NOW REMAIN UNCHANGED WITH RESPECT TO OCCUPANT NOTIFICATION FOR THIS FACILITY, AS SUCH, CONTRACTOR ATTESTS FACILITY IN COMPLIANCE WITH EDMONDS MUNICIPAL CODE 19.25.035 (4). SHOULD FIELD INSPECTION EFFORTS REQUIRE MODIFICATIONS TO PREVIOUSLY APPROVED OCCUPANT NOTIFICATION, SUCH MODIFICATIONS SHALL BE ANNOTATED AND INSTALLED PRIOR TO FINAL FIRE INSPECTION. PROJECT SCOPE RESPONSIBILITIES: PERFORMANCE SYSTEMS INTEGRATED, WHOLLY AND/OR THROUGH THE USE OF SUBCONTRACTORS TO FURNISH/INSTALL ALL EQUIPMENT SHOWN (UNLESS NOTED). LOW VOLTAGE WIRING, ROUGH IN, TRIM AND DEDICATED 120V CIRCUIT MODIFICATIONS SUBJECT TO CITY OF BELLEVUE PERMIT 24 104790 BF. FIRE ALARM COMMUNICATION METHOD: FIRE ALARM: PREVIOUSLY APPROVED SOLE PATH CELLULAR COMMUNICATION. ALL MONITORING INFORMATION, ACCOUNT NUMBERS AND TELEPHONE NUMBERS SHALL BE CONSPICUOUSLY DISPLAYED AT THE FIRE ALARM CONTROL PANEL. SECONDARY POWER SUPPLY/VOLTAGE DROP CALCULATIONS SECONDARY POWER SUPPLY CALCULATIONS: INSTALLATION DOES NOT AFFECT THE SECONDARY POWER SUPPLY CALCULATIONS OF THE REMOTE/BOOSTER POWER SUPPLY, OR THE CELLULAR COMMUNICATOR. THE SECONDARY POWER SUPPLY CALCULATIONS FOR THE MAIN FIRE ALARM CONTROL PANEL ARE SUBMITTED AS PART OF THE ASSOCIATED PRODUCT DATA SHEET SUBMITTAL PACKAGE/FILE. VOLTAGE DROP CALCULATIONS: ALL OCCUPANT NOTIFICATION DEVICES, AND THE CIRCUIT LAYOUT EMPLOYED IN FACILITY REMAIN UNCHANGED AND CONTAINED TO THE REMOTE/BOOSTER POWER SUPPLY. AS SUCH ALL PREVIOUSLY APPROVED CONDITIONS TO REMAIN AS IS. 212300 HIGHWAY 99, EDMONDS, WA GENERAL INSTALLATION NOTES 1. THESE GENERAL NOTES PER PERFORMANCE SYSTEMS INTEGRATION LLC (PSI), MAY NOT BE IN EFFECT FOR THIS INSTALLATION AND SCOPE OF WORK. FOR THE PURPOSE OF THIS INSTALLATION THESE PLANS SHALL BE IN ACCORDANCE WITH NFPA72 7.4. SPRINKLER MONITORING AND FIRE ALARM ARE INTERCHANGEABLE AND EQUAL. SEE SCOPE/PROJECT NARRATIVE. 2. CITATIONS FROM IBC/IFC ARE DEFAULT TO THE 2021 EDITION AS ADOPTED BY THE STATE OF WASHINGTON PER WAC 51-50. CITATIONS FROM NFPA72 ARE DEFAULT TO THE 2025 EDITION. IF THE SUBJECT NFPA72 CITATION DIFFERS FROM A PREVIOUS EDITION ENFORCED, ADDITIONAL CITATIONS SHALL BE PROVIDED. 3. PER IFC 907.1.3, ALL WIRE AND DEVICES CONNECTED TO THE FIRE ALARM SYSTEM SHALL BE LISTED BY AN APPROVED LISTING AGENCY (TYPICALLY UL OR FM,) COMPATIBLE, AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND INSTRUCTIONS. INSTALLATION SHALL BE IN ACCORDANCE WITH ALL AUTHORITIES HAVING JURISDICTION (AHJ), NFPA, IFC, NEC, WAC, MUNICIPAL CODE, AND CONTRACT DOCUMENTS. 4. FIRE ALARM DOCUMENTATION SHALL NOT BE STORED IN THE FIRE ALARM CONTROL UNIT PER NFPA72 7.7.2, AN APPROPRIATE RECORDS ENCLOSURE SHALL BE SUPPLIED. 5. ALL 120VAC WIRING TO CONTROL UNITS AS DEFINED BY NFPA72 (2025ed = 3.3.71, 3.3.117, 3.3.219 1 2022ed = 3.3.68, 3.3.115, 3.3.214 1 2019ed = 3.3.63, 3.3.108, 3.3.206) SHALL BE PERMITTED (SEPARATELY IF REQUIRED BY AHJ AND INSTALLED BY AN ELECTRICAL CONTRACTOR LICENSED TO PERFORM SUCH WORK. ALL 120VAC WIRING TO CONTROL UNITS AND POWER SUPPLIES SHALL BE DEDICATED, LABELED, AND INSTALLED WITH A BREAKER LOCK. ALL CONTROL UNITS AND POWER SUPPLIES SHALL NOT BE ENERGIZED WITHOUT THE PRESENCE OF PSI STAFF. ALL 120VAC WIRING ENTERING FIRE ALARM CABINETS SHALL BE THROUGH DEDICATED KNOCKOUTS, AND SHALL MAINTAIN A MINIMUM OF 0.25" SEPARATION FROM POWER LIMITED/LOW VOLTAGE WIRING. 6. THIS PROJECT EMPLOYS A SEPARATE ELECTRICAL CONTRACTOR AND FIRE ALARM CONTRACTOR IN A JOINT VENTURE. UNLESS OTHERWISE NOTED BY ANY CONTRACT DOCUMENTS, THE ELECTRICAL CONTRACTOR SHALL PERMIT (SEPARATELY, IF REQUIRED BY THE AHJ), FURNISH AND INSTALL ALL BACKBOXES, RACEWAY, AND WIRE PER PSI SPECIFICATIONS. ELECTRICAL CONTRACTOR SHALL INSTALL ALL SPECIALTY BACKBOXES, ENCLOSURES, FIRE ALARM TERMINAL CABINETS PROVIDED BY PSI. 7. WIRING SHALL CUT FOR IN/OUT. WIRING SHALL BE METERED AND VERIFIED TO BE CONTINUOUS, FREE FROM GROUND, SHORTS, OR ANY OTHER FAULTS. WIRING SHALL NEVER BE LOOPED THROUGH DEVICES, ALL SPLICED WIRE POSSESSING SHIELD SHALL HAVE SHIELDS SPLICED AND TAPED TO PREVENT GROUND FAULTS. WIRING SHALL RUN CONTINUOUS FROM SOURCE TO FIRST DEVICE ON CIRCUIT THEN FROM DEVICE TO DEVICE WITHOUT SPLICING IN PULL BOXES OR OTHER BACKBOXES OF DIFFERENCT CIRCUITS. 'IT -TAPPING" OF CONVENTIONAL INITIATION (IDC'S) OR NOTIFICATION APPLIANCE CIRCUITS (NAC'S) WILL RESULT IN A NON FUNCTIONAL SYSTEM, AND IS STRICTLY PROHIBITED. 8. WIRING SHALL BE IN CONDUIT, OR CONCEALED/HIDDEN. SURFACE MOUNT WIRING INSTALLATION ALLOWABLE WHEN APPROVED BY OWNER, OWNER REP., OR PROJECT TEAM AND COMPLIANT WITH ADOPTED CODES. 9. NUMBERS ADJACENT TO NOTIFICATION SYMBOL DENOTE DEVICE CIRCUIT/ADDRESS, OR NOTIFICATION SETTING. EXAMPLE DEVICE S0.2-6 WOULD BE SIXTH DEVICE ON NOTIFICATION CIRCUIT 0.2, FOLLOWED BY A MINIMUM CANDELA RATING SETTING. NOTIFICATION CIRCUIT WIRING IS SUPERVISED. PARALLEL BRANCHING IS NOT PERMISSIBLE. 10. IN ACCORDANCE WITH IFC 907.2 AND NFPA72 23.8.5.1.2, MANUAL PULL STATIONS INSTALLED IN A SPRINKLER RISER ROOM SHALL BE ACTIVE AT ALL TIMES INCLUDING DURING SPRINKLER OR AUTOMATIC DETECTION IMPAIRMENT, OR WHEN SYSTEM IS IN "TEST". APPROPRIATE WARNING SIGNAGE SHALL BE PLACED ADJACENT. 11. PERFORMANCE SYSTEMS INTEGRATION SHALL PROVIDE RECORD OF COMPLETION AT FINAL INSPECTION WITH AHJ. DOCUMENTATION SHALL BE STORED IN A DOCUMENT CABINET. SEQUENCE OF OPERATIONS/SYSTEM MATRIX FUNCTIONAL MATRIX NOTES: A0. NO ENTRY = NOT APPLICABLE. NOT ALL INPUTS MAY BE APPLICABLE TO PROJECT Al. VERIFY WITH RESPECT TO EXISTING ELEVATOR, AND THE AMSE CODE IT IS INSTALLED TO. THIS PROJECT SHALL NOT DEVIATE FROM EXISTING. A2. AC LOSS DELAY OF 3-6 HOURS. A3. SYSTEM WILL COMMUNICATE IF ABLE. SYSTEM INPUTS SYSTEM OUTPUTS FIRE ALARM NOTIFICATION FIRE CONTROL SAFETY UNIT CONTROL _ �O _ 0�=O v Q. j=o C_j Q p Q Q 4.4: O=�O� j ti �� �� �O �, O �O �O �O � ti0 _J m Z ti0 OZ O OZ v �tiO v� `� O=� �C� '`J 4Z �v �v ��0�� Qom,` A B C D E F G H I J K L M N P Q R S T U V W X ANY SMOKE DETECTOR 130000130001300011000NEILIENES Ll ELEV LOBBY SMOKE DETECTOR 1300001300013000110013013130000 0 L2 ELEV LOBBY SMOKE DETECTOR 1300001300013000110130013130000 0 ELEV SHAFT SMOKE DETECTOR 1300001300013000110130211130009 0 ELEV MACHINE ROOM SMOKE DETECTOR 1300001300013000[10130013130000 0 ANY MANUAL PULL STATION 0 ANY DUCT SMOKE DETECTOR 0 ANY WATERFLOW 0 ANY TAMPER SWITCH 01300000000130000000000000 eeee�eeee�e� AC POWER FAILURE LOW BATTERY OPEN CIRCUIT SYSTEM RISER DIAGRAM INITIATION/SLC CIRCUITS NOTIFICATION CIRCUITS (EX) INITIATION/SLC CIRCUITS (MODIFIED) ADD NEW MODULE & TEMP SENSOR NOTIFICATION CIRCUITS (EX) NOTIFICATION CIRCUITS (EX) SOUTH COUNTY FIRE APPROVAL Approved with Conditions Fire Marshal Chris Burt 12/31 /2024 12-31-2024 CONDITION: Prior to inspection date have AC power turned off for 24 hours prior for 5 minute ring down test. DFM Burt DATE: 2024.11.21 ERIC HAMERSKI, SET NICET FIRE ALARM SYSTEMS LEVEL IV: 118193 EXP: 2027.12.01 THE INFORMATION ON THIS DRAWING IS THE ORIGINAL, UNPUBLISHED WORK OF PERFORMANCE SYSTEMS INTEGRATION LLC. EXCEPT WHERE SUBJECT TO RCW 42.56, DISCLOSURE, REPRODUCTION, OR USE WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS INTEGRATION LLC IS PROHIBITED. ©2024 Ln z O Q u z O V u V u w In N� LL Q J w U_ IIII— �z O'er' >_2 0 LU U Q6100O No 0 J OF)O Q Q 00 QLJJ=�� (�� 00 Uo �Uo0o Qc) �LL(V = 0 Lu< � CID LU rn � N i Q N J Q m z O D N z u w LU 0 0 J Q z w CD DRAWN BY : E. HAMERSKI CHECKED BY : E. BARKER INITIAL DATE : 2024.12.23 PROJECT NO. :35117326 PERMIT NO. : TBD SHEET TITLE FIRE ALARM SYSTEM INFORMATION RECEIVED Dec 23 2024 CITY OF F I R2024-0124 DEVELOPMENT SOERVICES DEPARTMENT 10/_I1011: 01 NEW SURGE SUPPRESSOR SHEET NUMBER FAO.O 1 NOTES 0-BACKGROUND PLANS PROVIDED BY CITY OF EDMONDS PUBLIC RECORDS OO REQUEST (BLD2017-1326) WERE TRUNCATED BY THE CITY. ADDITIONAL PLANS UNAVAILABLE. 1-ALL OCCUPANT NOTIFICATION TO REMAIN EXISTING AS IS AND COMPLIANT O1 WITH THE CITY OF EDMONDS MUNICIPAL CODE FOR BOTH ORIGINAL INSTALLATION (IFC2013/NFPA72 2010) AND CURRENTLY ADOPTED IFC/NFPA CODES. FIRE ALARM CONTROL PANEL/SPRINKLER ROOM • REPLACE FIRE ALARM CONTROL PANEL • REPLACE ALL MODULES/INITIATION DEVICES (1:1 RATIO) • ENSURE SPRINKLER ROOM MANUAL PULL STATION INSTALLED ADJACENT. • INSTALL NEW DOCUMENT ENCLOSURE ADJACENT TO FACP AREA OF WORK, ALL OTHER AREAS • INSTALL NEW LOW TEMPERATURE SENSOR ADJACENT TO RISER EXISTING, TO REMAIN AS IS, NOT IN • RETAIN EXISTING BOOSTER POWER SUPPLY CONTRACT, UNLESS NOTED. 12 11 10 9 8 7 6 I FIRE RISER I I e ve I 151 WR at, I ",Nlro U T I M M M I --= OUTPUT 3 s_ - - - STORAGE/EQUIP. All��e.�� o00 fl -oeee e �ao —e . g,� e o ma iui ea 3 13 } TECH LOUNGE r-) (D]Q` (_I 15( 1 1 170 1 CH (TOILET F16T , TECH LOCKER 16$ �� 0 6 v 95cd E0 7 I 7— 160 �I WASH/DETAIL ❑ 160 I RK 14& o � l a 95cd 13 f 147 133 WAITING ia3 If: EXISTING FIRE ALARM LEGEND QTY SYMBOL DESCRIPTION MANUFACTURER MODI-L # I01000G —RLCD 1 [FAC Fire Alarm Control Panel —EST NN Remote Anunciator —EST 1 RP Remote Power SuEply HOCHIKI DE10SN Smoke Detector/CO HOCHIKI ALN Smoke Detector Sounder Base HOCHIKI HOCHIKI LN ASBL Smoke Detector —EST SIGA-OSD M Wireless Smoke Det.. HONEYWELL 3808LST O Heat Detector HOCHIKI SD505f3AHS 28 ® Horn Strobe Ceiling Mounl HOCHIKI CC24(;RWHITE 10 ® Strobe Ceiling Mount HOCHIKI ES3—)-4WNITE 1 0, Horn Strobe Wail Mount HOCHIKI EC3—)4WR 7 Strobe Wall Mount HOCHIKI[lES3f_4WHITE 1 F❑ Pull Station BEST SIGA-OSD F ❑ Wireless Pull Station ONEYWELL IRELITE BG12 6 nM Addressable Input Module EST I A- Tx 3 LY Addressable Relay Module EST SIGA-CR SP SUB PANEL HONEYWEH VISTA 128 FBP If RFR Wireless Receaver. HONEYWELL 5881 ENHC B Out Side 10' Bell HOCHIKI GB10-24 1 C HILL COMMUNICATOR HONEYWELL IPGSM--4G ^' Duct Detector Provided By other.. PREWIaE ONLY * =DENOTES ABOVE CEILING ADDITIONAL COMPONENTS TO BE ADDED: 1 POTTER RTSO - LOW TEMPERATURE SENSOR 1 EST SIGA-CT1 -INPUT MODULE 1 SPACE AGE SS000689 - DOCUMENT BOX 1 SPACE AGE E120VGT - SURGE SUPPRESSOR rimnn-ii nnoF Du [:j -� VESTIBULE Fl-32 SERVICE WRITERS ui SFR4CIE HECK -IN GREETER I QUICK LURE -, oP 145ERVICE CHECK —IN SERVr CHEC. IN SERVICE RECPT. VALET �o � 143 142 I 141 I 140 IL — — 95cd SERVICE . _ _ 1 �—�- SUPPORT p. 95Cd 5 i 45 l j 11 16 r F SERVICE o V ICE °1 R ��--� \� ; o- e PROJECT NORTH FIRE ALARM -- PARTIAL LEVEL �PLA�-SALE- 1/8" = 1' 16' o_ -0 RETAIL — 130 IE RETAIL PARTS CASHIER `127 126 ARTS _�01 • 11 /;1 CORRIDOR 123 121 ELEVATOR NEW CAR MGR DESKING 1l nR I L (4oh DATE: 2024.11.21 ERIC HAMERSKI, SET NICET FIRE ALARM SYSTEMS LEVEL IV: 118193 EXP: 2027.12.01 THE INFORMATION ON THIS DRAWING IS THE ORIGINAL, UNPUBLISHED WORK OF PERFORMANCE SYSTEMS INTEGRATION LLC. EXCEPT WHERE SUBJECT TO RCW 42.56, DISCLOSURE, REPRODUCTION, OR USE WITHOUT THE PRIOR WRITTEN CONSENT OF PERFORMANCE SYSTEMS INTEGRATION LLC IS PROHIBITED. ©2024 Ln z O Q V z O V u V v w Q J Q w LL o w Q z w w ~O z Z C� 9 z w O 9 ��U No gx= r rn Q � � O �LLI <0J� ,o � p[�< 5 z °Qw3C) >: �000 LLM <ULLI �=zo Lj UoOoL � co o CD r) " Lu < I I I I I I I I I I I I I I m w I I I I I I I M � N I Q I I I I I I C N J Q m z o N z I I I I I I I u w o � a z w I I I I I I I CD DRAWN BY : E. HAMERSKI CHECKED BY : E. BARKER INITIAL DATE : 2024.12.23 PROJECT NO. :35117326 PERMIT NO. : TBD SHEET TITLE FIRE ALARM SYSTEM INFORMATION RECEIVED Dec 23 2024 CITY OF EDMONDS FIR2024-0124 DEVELOPMENT SERVICES DEPARTMENT SHEET NUMBER FA1.01