FIR2024-0124+Fire_Alarm_Equipment_Specification_Sheets+12.23.2024_11.39.57_AM+4684208RECEIVED FIR2024-0124 Dec 23 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PERFORMANCE SYSTEMS INTEGRATION Fire Alarm Submittal For Swickward Toyata 21300 Highway 99 Edmonds, WA 98026 Performance Systems Integration 301 Porter Way Milton, WA 98354 Phone: 425.368.4201 LIC: PERFOSI81250 PSI Project #35117326 Project Manager Eric Barker Project Designer Doug Crandell ET December 20, 2024 Proprietary document for approval only Table of Contents Swickward Toyata PERFORMANCE SYSTEMS INTEGRATION SCOPE OF WORK EQUIPMENT LIST & INFORMATION SHEETS BATTERY CALCULATIONS SCOPE OF WORK Swickard Toyota - Edmonds Existing Building: The fire alarm system requires replacement. Performance System Integration will be replacing the current fire alarm system, along with associated automatic and manual fire alarm devices. The building fire alarm was originally permitted under BLD202171326 with an approval date of 9/25/18. The current occupant notification layout of the facility, plus the initiation requirements meet currently adopted City of Edmonds municipal code. Swickard Toyota - Edmonds /I Sviekard Toyota EQUIPMENT LIST Swickward Toyata 35117326 1212012024 PERFORMANCE SYSTEMS INTEGRATION Item Part # Manufacturer Qty Description 1 101000GD EST 1 Fire Alarm Control Panel 2 SA-ETH EST 1 Ethernet Communication Card 3 RCLD-CR EST 1 Remote Annunciator 4 E120VGT SPACE AGE 1 Surge Protection Device 5 SIGA-OSD EST 6 Smoke Detector 6 SIGA-SB4 EST 6 Standard Detector Base w/Trim Ring 7 SIGA-278 EST 1 Manual Pull Station 8 SIGA-CT1 EST 6 Single -Input Monitor Module 9 SIGA-CR EST 3 Control Relay 10 SS000689 SPACE AGE 1 Document Cabinet PROPRIETARY DOCUMENT FOR APPROVAL ONLY 1 T D Printed: 4:20 PM 12/20/2024 I Er. WARDB LIFE SAFETY 7 INCIDENT MANAGEMENT Intelligent Fire Alarm Systems Cosa. io, 000 Overview EDWARDS brand intelligent life safety systems offer the power of high -end intelligent processing in configurations that deliver uncomplicated solutions for small -to -mid -sized applications. With intelligent detection, electronic addressing, automatic device mapping, optional Ethernet® connectivity, and a full line of easily - configured option cards and modules, these flexible systems offer versatility that benefits building owners and contractors alike. The i064 provides one Class A or Class B intelligent device loop that supports up to 64 device addresses, and two Class B Notifi- cation Appliance Circuits (NACs). Optional Class A device wiring is available with the use of a module. The i01000 provides one Class A or Class B intelligent device loop that supports up to 250 device addresses. Loop controller modules may be added in combination to expand total system capacity in 250-point increments to up to 1,000 device addresses. The i01000 panel includes four NACs that may be wired for either Class A or Class B operation. The RZI16-2 module adds even more capacity to iO installations by adding up to 16 conventional device circuits and two additional notification appliance circuits. This makes them an ideal retrofit solution that can accommodate new intelligent detectors, as well as existing conventional devices. iO Series supports a wide range of high -end features, including: • Supports 10-Year Carbon Monoxide detectors • R-Series remote annunciators • SIGA-REL Releasing Modules • Fully integrated CO detection using Signature Series detectors with or without audible signaling EDWARDS° Catalog ► Small Building Fire Alarm Solutions FM FDNY COA 6227 0 7165-1657: 0244 u� UDC S3000 Features • Auto -programming reduces installation time • Supports Signature Series intelligent modules and detectors • Combines the Signature intelligent releasing module with Signature multisensor detectors for reliable fire suppression • Electronic addressing with automatic device mapping • Optional Ethernet port (SA-ETH) for central station monitoring service, programming, diagnostics and a variety of system reports. • Two programmable switches with LEDs and custom labeling • Supports Genesis horn silence over two wires, and UL 1971-compliant strobe synchronization • Optional multi -protocol Field Server Bridge for interface to third -party Building Management Systems. • Ground fault detection by module • Supports up to eight serial annunciators, (LCD, LED -only, and graphic interface) • Can use existing wiring for most retrofit applications • Upload/download remotely or locally • Optional USB module for local printing or programming using the configuration utility on a technician's laptop. • Two -level maintenance alert reporting • Pre -alarm and alarm verification by point • Adjustable detector sensitivity • 4 x 20 character backlit LCD display • Optional earthquake hardening: seismic Importance Factor 1.5 • Standalone operation • Alarm ON command manually activates alarm condition • Form C contacts for alarm and trouble, Form A for supervisory Page 1 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 Application The EDWARDS iO Series life safety systems are powerful intelligent solutions for small to mid -sized buildings. Advanced intelligent technology delivers the benefits of flexible system installation, while clean and easy -to -operate user interfaces make panel operation and system maintenance quick and intuitive. The smart choice Signature Series electronic addressing eliminates the tedium of setting dip switches, and automatic device mapping ensures that each device resides on the system at its correct location. Mean- while, innovative programming allows the designer to customize the system to precisely suit the needs of the building owner. Reliability you can count on The inherent fault -tolerant characteristics of Analog/Addressable Technology boost the reliability of EDWARDS brand fire alarm systems. When combined with iO Series smoke and heat detectors, these systems deliver a level of dependability not previously available for small -to -mid -sized applications. All EDWARDS systems are built to exacting reliability benchmarks. Clear-cut remote annunciation Remote annunciation is a strong suit of the iO Series fire alarm systems. Up to eight annunciators can be installed on a single system. Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation, as well as common control capabilities. iO control panels also support graphic annunciation with optional RA Graphic Annunciator interface modules. Each interface provides common control and 32 LEDs. Flexibility built right in Two fully -programmable front panel switch/LED combinations provide an added measure of flexibility. Their slide -in labels take the mystery out of custom applications, and present a clean, finished appearance. Programming and remote diagnostics The EDWARDS iO Series life safety systems are simple to set up, yet offer advanced programming features that put these small building panels into a class of their own. The auto programming feature quickly gets the panel operational using factory default settings. Basic zone and point settings can be programmed through the front panel interface, so the system is up and running in no time. For more advanced system configuration and correlation groups programming, iO Series systems interface to a PC running com- patible iO-CU software. This option offers full system configuration in the familiar Windows° operating environment. Connection is made to a laptop through the panel's optional RS-232 communi- cations port, which can also be used to connect a system printer. Among the many innovative features of iO Series control panels is the optional network card. This module provides a standard 10/100 Base T Ethernet® network connection that permits access to the control panel from any remote location with the correct communications protocols. The connection can be used to download to the panel from the iO-CU, or upload and view system reports using the iO-CU. Available system reports include: Correlation groups, Device details, Device maintenance, History, Internal status, System configuration, System status, Walk test, Dialer, and CO runtime. Perfect for retrofits The EDWARDS iO Series control panels are particularly well -suited to retrofit applications. All connections are made over standard wiring - no shielded cable required. This means that in most situations existing wiring can be used to upgrade a legacy control panel to iO technology without the expense or disruption of rewiring the entire building. iO control panels also support the ingenious RZI16-2 Zone Module, which adds up to 16 conventional circuits and two NACs. This combination easily accommodates new intelligent detection alongside existing conventional circuits, making it a superior solution in the retrofit market. Scalable IP and Cellular Communications Optional SA-ETH module supports IF connection to a central sta- tion's Sur -Gard receiver, meeting one of the methods of communi- cation allowed by NFPA 72 as of the 2013 Edition. Several popular third -party IP/Cellular communicators have been tested with the iO control panels and are compatibility -listed to UL864. The IP/Cellular communicators meet NFPA72 2013 edition requirements for sole or secondary transmission paths. Using IP/Cellular communicators can reduce the cost of ownership by eliminating POTS lines. Please see the iO control panel compatibility documentation part number 3102353-EN for a full list of compatible communicators. Signals with a difference iO system NACs are configurable to fully support the advanced signaling technology of the EDWARDS Genesis and Enhanced Integrity notification appliances. These devices offer precision synchro nization of strobes to UL 1971 standards. For Genesis devices, enabling this feature allows horns to be silenced while strobes on the same two -wire circuit continue to flash until the panel is reset. A complete line of accessories iO Series life safety systems are supported by a complete line of analog/addressable detectors, modules and related equipment. Consult the Ordering Information section for details. Dimensions U (2) (3) (4) 7 D� ° O ° °O O O O O O O O D4 O D8 O O ° ND9►I D9► (1) Surface Mounting Holes (3) Backbox with Door Attached (2) Semi -flush Mounting Holes (4) Backbox with Door and Trim Kit attached Panel dimensions, in (cm) Model D1* D2 D3 D4 D5* D6 D7 D8 D9 01000 28.0 3.85 9.0 22.0 15.75 4.4 28.2 2.7 (71.1) (9.8) (22.8) (55.8) (40.0) ) (11.1) (71.6) (6.8) i064 21.5 3.85 7.5 15.5 14.25 E(26. 4.5 21.7 E7 (54.6) (9.8) (19.0) (39.4) (36.2) ) (11.4) (55.1) (6.8) * Add 1-1/2 in. (3.81 cm) to D1 and D5 dimensions for trim kit. The trim kit provides 0.75 inches (1.9 cm) of trim to the top, bottom, and sides of the backbox. Page 2 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 System Layout Any combination of two single- or dual Signature loop modules �—f l I®711, 'StailtTMI'Mop: 250 poi expansion -SDC2 Expander, Loo : 2 s Up to 125 sensors expansion and 125 modules per loop ( p ansion I - 1 xpander Loop: 25 poln s (one expansion s o -SDC2 Expander, Loo : 2 s ,Up to 20,000 feet of wiring per loop Four Class B or two optional Class A Optional 10 A or 6.5 A Booster Ethernet SA-ETH DACT/Dialer (SA-DAC-0 RS-232 (SA-232 or SA-USB)" Relays: Two Form C, one Form A Each i01000 panel has room for up to two Signature loop controller modules in any combination of single or dual 250-device loops. i01000 loops support 125 detectors and 125 modules. i064 Up LU LU,000 IUUL UI WIIII Ig. )tional 10 A or 6.5 A Booster Power Supply Ethernet (SA-ETH)`] DACT/Dialer (SA-DACT)] RS-232 (SA-232 or SA-USB)" — Relays: Two Form C, one Form A — Sixteen Conventional IDCs, two additional NACs with Each i064 panel ships with one Signature loop RZI16-2 module controller that supports 64 devices of any type. This panel's device capacity cannot be expanded. ,en Conventional IDCs, additional NACs with RZI16-2 module Panel Layout 3 2 1 Transformer 2 Main AC wiring block & fuse holder 3 RS-232 card connector (J3) 4 Dialer card connection (J8) 5 Ethernet card connector (J1) 6 Main circuit board 7 Panel backbox enclosure 8 Operator interface 9 SLC card connector (J7) 10 Class A card connector (J2) 11 Tie wrap mounts 12 LED expander connector (J6) 13 Standby batteries 'SA-ETH supports: (1) remote connectivity for diagnostics & programming, (2) Central station monitoring to Sur -Gard IP Receivers. "RS-232 supports: (1) Printer, (2) Programming Interface, (3) Use of Field Server Briidge (SA-FSB) for third -party Building Management Systems interface. 13 Page 3 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 Wiring & Configuration Signature device loop The system provides one Signature device loop circuit with a total capacity of 125 detectors and 125 module addresses. The loop circuit is supervised for opens, shorts, and grounds. Circuit i01000 1064 specifications Device loops One Class B or A One Class B or A loop, loop, supporting 125 supporting 64 devices of detectors and 125 any kind. modules. Expandable to four loops. Communication Maximum 20 V peak -to -peak line voltage Circuit current 0.5 A max Circuit 66D total, 0.5 NF, max impedance Isolators 64 maximum Signal Supported on a system -wide basis (all device loops) Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module and Genesis or Enhanced Integrity notification ap- pliances. Class B wiring Class A wiring Loop 1 SEC + Data Line Loop 1 SEC + Loop 1 PRI + + + Loop 1 PRI + + + Loop Loop Loop Loop Loop card device device Loop card Data Line device device Notification appliance circuits (TB2) i01000 control panels come equipped with four notification ap- pliance circuits. i064 control panels come with two NACs. Each circuit can be individually configured for continuous, temporal, synchronized, and coded output. Specifications 1101000 1064 Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A with SA-CLA module Voltage 24 VFWR Current 6.0 A total, 2.5 A max. 3.75 A total, 2.5 A max. per circuit at 120/230 per circuit at 120/230 VAC 60 Hz. VAC 60 Hz. 5.0 A total, 2.5 A max. 3.0 A total, 2.5 A max. per circuit at 230 VAC per circuit at 230 VAC 50 Hz. 50 Hz. Impedance 26 Q total, 0.35 uF max EOLR 15KD,1/2W Synchronization Supported system -wide Class B wiring OLR OLR Class A wiring Marking indicates output signal polarity when the circuit is active. Polarity reverses when the circuit is not active. Wire notification appliances accordingly. Notification appliance polarity shown in active state. Auxiliary & smoke power outputs (TB3) The control panel provides two auxiliary power outputs that can be used for powering ancillary equipment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software - selected to operate continuously. The circuit is supervised for shorts and grounds. (2) Circuit specifications Circuit voltage 21.9 to 28.3 V range Resettable circuit 24 VDC nominal at 500 mA (3) (Aux power 2) Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering two -wire smoke detectors. (4) Note: Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that amount. (1) Trouble Alarm, trouble, and supervisory relay (TB3) (2) Supervisory The trouble relay is normally -open, held closed, (3) Alarm and opens on any trouble event or when the panel is de -energized. The supervisory relay is (4) Smoke/Aux normally -open, and closes on any supervisory event. The alarm relay changes over on any alarm event. Relay specifications Alarm Trouble Supervisory Type Form C Form A Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive Relay circuits can only be connected to power -limited sources. Annunciator loop (TB4) The control panel provides a connection for up to eight serially driven and supervised remote annunciators. Circuit specifications Device loops Class B (Style 10 or Class A (Style 2) Circuit voltage 2.55 V Circuit current 30 mA max Circuit Up to 8 annunciators or 4000 feet impedance Class B Channel Channel Class A Channell Channe12 TB4 Annunciator CH1 (+) IN CH2 (+) IN CH2 (—) IN Annunciator CH1 (+) IN CH1 (—) IN CH2 (+) IN CH2 (—) IN Page 4 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 Option Cards EDWARDS brand iO Series panels are supported by a complete line of modules and related equipment that enhance performance and extend system capabilities. Option cards plug directly into the control panel main circuit board or are connected to it with a ribbon cable. After installation, terminals remain accessible. The cabinet provides ample room for wire routing, keeping wiring neat at all times. Single and Dual Loop Controller Cards The iO-SDC1 is a single loop controller card that can be used with the i064 as a replacement for the standard 64-point loop, or with the i01000 as a 250-point expansion module. The iO-SDC2 is a 500-point dual loop controller card for the i01000 that provides two SLC circuits, each with 125 detector addresses and 125 module addresses. Specifications iO-SDC1 10-SDC2 Device Addresses iO1000: one loop, 250 device add resses i064: 64 addresses i01000: two loops, 500 device addresses Wiring Class B or Class A Operating Voltage 24 VDC Operating Current (fully loaded loop) Standby: 55 mA Alarm: 80 mA Standby: 45 mA Alarm: 70 mA Note: These ratings do not include the use of two -wire smoke modules. Communication Line Voltage Max. 20.6 V peak -to -peak Terminal Rating 12 to 18 AWG (0.75 to 2.5 mm2) Circuit Current 0.5 A max. Max total loop resistance 66 Q Max total loop capacitance 0.5 pF Isolators 64 isolators maximum per loop (total both isolator bases and modules) Ground Fault Impedance 0 to 5 kQ Operating Environment 32 to 120°F (0 to 49°C) 1 0 to 93% noncondensing at 90OF (32°C) SA-ETH Ethernet Interface Card/IP Communicator The SA-ETH card provides a standard 10/100 Base T Ethernet network connection for connecting to an intranet, a local network, or the Internet. The card supports IP connectivity for monitoring services by a supervising station to meet NFPA 72 Chapter 26. The Ethernet card uses the FIBRO protocol to communicate with Sur -Gard System receivers (see below). The card can be used to download configuration programming from the iO-CU to the panel. ii The Ethernet card is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-ETH specifications Ethernet 10/100 Base-T Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90oF (32°C) Compatible Sur -Gard Receivers SG -System I, II, III, IV and V RZI16-2 Remote Zone Interface Module c; 'a, q os ea o� o� eM�c The RZI16-2 Addressable Remote Zone Interface Module is an addressable device that provides connections for sixteen Class B Initiating Device Circuits and two Class B Supervised Output Circuits. The inputs and outputs can be configured individually for several device types. It requires 18 consecutive addresses on the Signaling Line Circuit (SLC). Addresses are assigned electronically. There are no address switches to set. The RZI16-2 incorporates two 8-segment DIP switches that are used to select the Alarm or Supervisory default device type for each of the 16 IDC circuits. The module also includes one 4-segment DIP switch used to select the default Relay or NAC output device type. Device types other than the default are accomplished through programming. RZI16-2 Specifications Voltage 24V/Aux nominal: 24 VDC Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA 24V/Aux minimum: 18.4 VDC 24V/Aux maximum: 26.4 VDC NAC1, NAC2 nominal: 24 VDC Current Standby current for 4.7 k EOL (U.S.) 4.8 mA/ circuit Standby current for 3.9 k EOL (Canada) 5.7 mA/ circuit Alarm current at nominal voltage 31.1 mA/ circuit Relay outputs Quantity 2 Type Rating (pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 O per wire resistance Initiating device circuits Quantity 16 EOL resistor 4.7 kO (U.S.); 3.9 kO Canada Zone voltage 22.78 V for 4.7 kO (U.S.) 22.08 V for 3.9 kO (Canada) Alarm current 31.1 mA/ channel at nominal voltage Alarm impedance range < 680 0 Trouble impedance range > 5.55 kO Supervised output circuits EOL resistor 15 kQ Quantity 2 Short circuit detection < 2.6 k0 Open circuit detection > 61.9 kQ Contact ratings 24 VDC at 2.5 A (5 A for two NACs) Compatible cabinets MFC-A, i01000, APS Page 5 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 SA-DACT Dialer The SA-DACT provides communications between the control panel and the central station over a telephone line system. It transmits system status changes (events) to a compatible digital alarm communicator receiver over the public, switched telephone network. The dialer is capable of single, dual, or split reporting of events to two different account and telephone numbers. The modem feature of the SA-DACT can also be used for uploading and downloading panel configuration, history, and current status to a PC running the i0-CU. The dialer phone lines connect to connectors a on the dialer's main circuit board. Phone line ie Jack 1 connects to connector J4 and phone line 2 connects to connector J1. The SA-DACT queues messages and transmits them based on priority (alarm, supervisory, trouble, and monitor). Activa- tions are transmitted before restorations. The SA-DACT is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-DACT specifications Phone line type One or two loop -start lines on a public, switched network Phone line connector RJ-31/38X (C31/38X) Communication formats Contact ID (SIA DC-05) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) Compatible DACRs Receiver Models Formats Ademco 685 Contact ID FBII CP220 Contact ID Osborne -Hoffman OH 2O00 Contact ID Bosch D6600 Contact ID Silent Knight 9800 Contact ID Sur -Gard SG-MLR1, MLR2 Contact ID The SA-USB Interface Card The SA-USB Interface Card provides a USB connection to a sup- ported printer or a connection to a PC. The card can be used for connecting a printer to the control panel to print system events. The card can also be used for uploading and downloading panel configuration, historty, and current status to a PC running the configuration utility (CU). SA-USB specifications Operating voltage 24VDC Current Standby/Alarm 13 mA, max 20mA Universal Serial Bus 1 USB Type A -host port J3 (printer connection) (USB) ports 1 USB Type B - device port J4 (CU connection) Supported Printer PT-1 S Printer communication speed 9600 baud Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing SA-232 RS-232 interface The SA-232 card provides an RS-232 interface with iO panels. It can be used for connecting a printer to the control panel to print system events. The card also can be used for connecting a computer to download a configuration program from the iO-CU to the control panel. The RS-232 card is installed on the plastic assembly and connects to the main circuit board via a ribbon cable. SA-232 specifications Operating voltage Standard EIA-232 Terminal rating 12 to18 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90oF (32°C) SA-CLA Class A Module (i064 only) The SA-CLA card provides Class A capability for NAC wiring. Its terminal block provides the wiring connection for NAC return wiring. The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card. The SA- CLA is compatible with i064 control panels only. i01000 panels are Class A Ready. The SA-CLA is installed directly to the control panel circuit board using its plastic standoffs and plug connection. SA-CLA specifications Operating voltage 24 VFWR Operating current 3.75 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Circuit impedance 26 ohms, 0.35uF Terminal rating 12 to18 AWG (0.75 to 2.5 sq mm) Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93% RH, noncondensing at 90°F (32°C) D16LAO LED Display Expander (i01000 only) The D16L-iO LED Display Expanders provide LED annunciation for up to 16 zones. It provides two LEDs for each zone. Two D16L-iO LED display expanders can be installed in each i01000 panel. (3) ,.. (4) (1) LED 1 (2) LED 2 (3) LED Expander 1 (4) LED Expander 2 (5) Alarm/non-alarm and trouble zone LEDs — (5) Page 6 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 Specifications iO64 iO1000 Device loops 1 loop Class B or Class A (Styles 4, 6, 7) supporting up to 1 loop, expandable to 4, Class A or B (Styles 4, 6, 7), 64 device addresses (any combination of detectors and each loop supporting up to 250 device addresses (125 modules) detectors and 125 modules max.). Addresses 1 to 125 are Maximum T-taps: 63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B (Style 1), Class A (Style Z) optional 4 Class B (Style 10 or 2 Class A (Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max. per circuit 2.5 A FWR each max. per circuit Primary power 120 VAC, 60 Hz, 1.3 A max. 120 VAC, 60 Hz, 2.0 A max. 230 VAC, 50-60 Hz, 0.62 A max. 230 VAC, 50-60 Hz, 0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max., RS-485 Class B, Class A is optional 8 drops max., RS-485 Class A or B Data line length: 4,000 ft. (1,219 m) Data line length: 4,000 ft. (1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA, 24 VDC (1 A possible if you reduce total available NAC power by 500 mA) circuit Aux power 2: 500 mA, 24 VDC Output: 28.3 to 21.9 VDC, special application Note: For a list of compatible devices, see the iO64 and iO1000 Series Compatibility List (P/N 3102353-EN) Loop circuit Maximum loop resistance: 66 0 Maximum loop capacitance: 0.5 pF Communication line voltage: Maximum 20.6 V peak -to -peak Operating current (fully loaded loop) Stand by: 55 mA/45 mA Alarm: 125 mA/115 mA (not including two -wire smoke modules) Circuit current: 0.5 A max. Style 4, 6, and 7 wiring Max. resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop (total both isolator bases and modules) Batteries Type: Sealed lead acid Voltage: 24 VDC Charging current: 2.47 A max. Amp hour capacity: 26 Ah Standby operation: 24 hour or 60 hour Placement: Up to two 10 Ah batteries will fit in the iO64 control panel cabinet and two 18 Ah batteries will fit in the iO1000 control panel cabinet. If larger batteries are required, use an EDWARDS battery cabinet. SA-DACT dialer Phone line type: One or two loop -start lines on a public, switched network Phone line connector: RJ-31/38X (C31/38X) Communication formats: Contact ID (SIA DC-05) Operating current Standby/Alarm: 41 mA Max.: 100 mA FCC registration number: GESAL01 BSADACT Industry Canada Registration number: 3944A-SADACT Ringer equivalence number: 0.1 B Ground fault impedance 0 to 5 kf2 Alarm contact Form C N.O. 24 VDC at 1 A (resistive load) Trouble contact Form C 24 VDC at 1 A (resistive load) Supervisory contact Form A N.O. 24 VDC at 1 A (resistive load) Environmental Temperature: 0 to 49°C (32 to 120°F) Relative humidity: 0 to 93% noncondensing Terminal rating All terminals rated for 12 to 18 AWG (0.75 to 2.5 mm2) Page 7 of 8 DATA SHEET E85OO1-0135 Not to be used for installation purposes. Issue 2.0 CDWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 ©2023 Carrier All Rights Reserved. Ordering Information Part Description i01000 Fire Alarm Systems 101000G Four loop system with one 250-point loop installed. 110v, gray door. 101000G-2 Four loop system with one 250-point loop installed. 230v, gray door. 101000G-2-PG Four loop system with one 250-point loop installed. 230v, gray door, Portuguese. 101000G-2-SP Four loop system with one 250-point loop installed. 230v, gray door, Spanish. 101000G-CA Four loop system, one 250-point loop installed. 110v, gray door, LED strips, Canada. 101000G-F Four loop system, one 250-point loop. 110v, gray door, LED strips, French Canada. 101000G-PG Four loop system with one 250-Doint IooD installed. 110v. arav door. Portuauese. 101000R Four loop system with one 250-point loop installed. 110v, red door. 101000R-2 Four loop system with one 250-point loop installed. 230v, red door. SA-TRIM2 i01000 Flush mount trim, black. i064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v, gray door. 1064G-2 One loop system with one 64-point loop installed. 230v, gray door. 1064G-2-PG One loop system with one 64-point loop installed. 230v, gray door, Portuguese. 1064G-2-SP One loop system with one 64-point loop installed. 230v, gray door, Spanish. 1064GL One loop system, one 64-point loop installed. 110v, gray door, English Canada. 1064GL-F One loop system, one 64-point loop installed. 110v, gray door, French Canada. 1064G-PG One loop system with one 64-point loop installed. 110v, gray door, Portuguese. 1064G-SP One loop system with one 64-point loop installed. 110v, gray door, Spanish. 1064R One loop system with one 64-point loop installed. 110v, red door. 1064R-2 One loop system with one 64-point loop installed. 230v, red door. SA-TRIM-1 i064 Flush mount trim, black Option Cards iO-SDC1 Expansion module, one 250-device loop. iO-SDC2 Expansion module, two 250-device loops, 500 devices total. For i01000 only. RZI16-2 Remote Zone Interface Module. 16 Class B IDCs. 2 Class B Cutout. Includes bracket. SA-ETH Ethernet Port, IP Communicator, mounts in cabinet on base plate. SA-CLA Class A adapter module. Provides Class A capacity on NACs. Mounts in cabinet on main board. i064 systems only. SA-FSB Field Server Bridge for connection to 3rd Party Building Management Systems. Supports BACnet and Modbus protocols. Mounts in the MFCA cabinet using the FSB-BRKT2 mounting plate. See separate SA-FSB datasheet E85010-0156 for additional information. SA-USB RS-232 Serial port for connection to printers & computers, mounts in cabinet. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32. For i01000 only. D16L-i0-1 LED Annunciator module, 16 X 2-LED zones (4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16. For i01000 only. D8RY-iO-2 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For i01000 only. D8RY-0-1 Canada only: LED Annunciator module, two LEDs per zone, 16 zones (4 alarm only, 8 supervisory only, 4 alarm or supervisory). Mounts in cabinet. For i01000 only. Accessories CTM City Tie Module. 2-gang. Connection to a local energy fire alarm box. MFC-A Multifunction Fire Cabinet, 8" x 14" x 3.5" - red. SIGA-REL Releasing Module PT-1S System Printer BC-1 Battery Cabinet. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 R Battery Cabinet - Red. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for iO series panels. Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools i0-CU 10 Series configuration and diagnostics utility. 260097 RS232 cable, 4 conductor, D139 PC interface Page 8 of 8 DATA SHEET E85001-0135 Not to be used for installation purposes. Issue 2.0 EDWARDS° Catalog ► Annunciation E WARDB LIFE SAFETY 7 INCIDENT MANAGEMENT R-Series Remote Annunciators RLCD, RLCD-C, RLED, BLED-C, RLED24, GCI Overview EDWARDS R-Series Annunciators are high-performance remote annunciators that provide status indication and common controls for compatible fire alarm control panels, including iO-Series small analog fire alarm systems. This family of annunciators offers LCD or LED annunciation. Models are available with and without com- mon controls. There are three R-Series annunciator models, plus an LED -based expander. Up to two expanders can be connected to any annun- ciator. The expander includes 24 pairs of LEDs that extend the capabilities of any of the annunciators. All annunciator models include status LEDs and an internal buzzer. Two models have an LCD text display, and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back -lit, four by twenty character per line, super -twist liquid crystal display. R-Series annunciators and expanders are mounted on a standard 4-inch square electrical box, using the included mounting ring. They can also be surface mounted in locking steel enclosures. Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications. The keyswitch enables or dis- ables common controls. The graphic annunciator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Q Power Q Fire Alarm 0 Supervisory Q Ground Faull 0 Trouble Controls Enabled AcklSilence OReset U �gnal Silence SON# 11wamo Test �+anw UL FDNY UUC a.Mm COA 6020 7120-1657. COA 6087 0254 S3424 Features • LCD models feature large 4 x 20 character backlit LCD display • LED models provide 16 pairs of LEDs for zone annunciation • Available expander extends capability with 24 pairs of LEDs • Up to two expanders may be wired to each annunciator • Status LEDs and internal buzzer standard on all models • Common controls available for LED and LCD display models • Available keyswitch for disabling common controls • Standard 4-inch square electrical box mounting • Class B or Class A RS485 wiring standard • One-, two-, and three -position enclosures available • Graphic Annunciator interface, includes common control, indi- cators and 32 LEDS • No programing required, set the address and unit receives all information from panel Page 1 of 4 DATA SHEET E85005-0128 Not to be used for installation purposes. Issue 1.1 Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator, Class A data riser. This can be configured for Class A or Class B commu- nication. Annunciators do not provide ground fault isolation. FADP Annunciator RS-485 CH1 (+) IN These annunciators are stand-alone units that can be powered by CHI, the FACP or by an approved power supply. CHI - CH2+ O•• I MS RLCD-C o 80 o0 o oo o so 0 of 00 o o of Lo so RUED-C of 80 8 °so oo °so of oo sly °so °so °so o o so o %0 8 CH2- 0 LISTED 24 VDC SUPPLY 24 VDC + 0 24 VDC - O) Annunciator, Class B FACP RS-485 CHI+ CH1 - RLCD RLED24 LISTED 24 VDC Features by RLCD RLCD-C RLED-C RLED24 SUPPLY model 24 VDC + 0 24VDC-0 Reset ✓ ✓ ✓ AcWSilence ✓ ✓ ✓ Fire Alarm ✓ ✓ ✓ Supervisory ✓ ✓ ✓ Ground Fault ✓ ✓ ✓ Trouble ✓ ✓ ✓ Controls Enabled ✓ ✓ ✓ Expander AcWSilence ✓ ✓ ✓ Reset ✓ ✓ Annunciator Signal Silence ✓ ✓ OUT v ( ) Drill ✓ ✓ v (+) Lamp Test ✓ ✓ ✓ F LCD Display ✓ ✓ E Zone Active LEDs 16* 24 `" D Zone Trouble LEDs 16 24 c RA * zones 13-16 may be selected as Supervisory on 1064 —zones 13-16 and 29-32 may be selected as Supervisory on i01000 CH2 (+) IN CH2 (-) IN CH2 (+) OUT CH2 (-) OUT 24V (+) IN 24V (-) IN 24V (+) OUT 24V (-) OUT GROUND Annunciator 0 CH, (+) IN 0 CH, (-) IN CH, (+) OUT CH, (-) OUT 0 CH2 (+) IN 0 CH2 (-) IN 0 CH2 (+) OUT 0 CH2 (-) OUT 0 24V (+) IN 0 24V (-) IN 24V (+) OUT 24V (-) OUT 0 GROUND Annunciator CH, (+) IN CHI (-) IN 0 CHI (+) OUT 0 CHI (-) OUT CH2 (+) IN CH2 (-) IN CH2 (+) OUT 0 CH2 (-) OUT 24V (+) IN 24V (-) IN 0 24V (+) OUT 0 24V (-) OUT GROUND Annunciator CHI (+) IN CH, (-) IN CHI (+) OUT 0 CHI (-) OUT 0 CH2 (+) IN 0 CH2 (-) IN 0 CH2 (+) OUT 0 CH2 (-) OUT 24V (+) IN 24V (-) IN 0 24V (+) OUT 0 24V (-) OUT GROUND First Expander Second Expander IN OUT IN OUT v(-) V(-)0- --------; -0VH v(-)0 v(+) v(+)0- -------- - -0v(+) v(+)0 F F - _______ F F D E E 0- E D D Da _ _______ D D0 C C 0- --------- 0 c C D B B --------- ;- B B 0 A A0- ------------[,0 ----------------------- A AD Graphic Annunciator Interface The GCI Graphic Annunciator Driver is an interface card that Remote Keyswitch connects the fire alarm control panel to the display panel of an LED -based graphic annunciator. Annunciator LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the KEYSWITCH (-) T81-, graphic panel display. It includes status LEDs and an internal KEYSWITCH buzzer. The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc voltage The annunciator communicates with the FACP on the RS-485 Maximum 200 mA data riser. This can be configured for Class A or Class B commu- current nication. The annunciator does not provide ground fault isolation. Mounting 2-1/2 in (64 mm) It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box approved power supply. Termination Screw terminals Maximum 12 AWG Graphic Annunciator Interface Specifications wire size (2.5 mm sq) Alarm current 146 mA at 24 Vdc (with 36 LEDs ON) Contact Normally open Standby current 36 mA at 24 Vdc (with no LEDs ON) confi uration 0 9 � Maximum current 10 mA per LED Page 2 of 4 DATA SHEET E85005-0128 Not to be used for installation purposes. Issue 1.1 Annunciator Connections Annunciator Mounting slot 0 DIP switch eeeeeee o RS-485 riser °8 terminals Power terminals Communication LEDs Expander Mounting slot Expander cable terminals DIP switch settings Remote keyswitch terminals Expander cable terminals Expander cable terminals Switch Description and values S1 to S5 The annunciator network address (in binary). Network The factory setting is for address 2. address Examples: 10000 = 1 01000 = 2 11000 = 3 00100 = 4 S6 Network OFF = 9600 baud (factory default setting) baud rate ON = 38,400 baud S7 to S8 Not used Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure, surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover, and key lock. The enclosures are 16-gauge welded steel with a white, painted finish. Each enclosure includes a security lock and two keys. The two- and three -position enclosures have wiring channels for cor- rect routing of interconnections. The enclosures attach to a standard electrical box, and provide a mounting lip that takes the place of the integral mounting ring sup- plied with the annunciators and expanders. 0 0 0 0 RA-ENC1 RA-ENC2 RA-ENC3 Annunciator Mounting MOUNTING RING EXPANDER ELECTRICAL BOX I_ 4.5 in 24'I I_ .1 cm _I 9.8 in 24.9 cm 6.0 in 15.2 cm H 0.9 in 2.3 crr 2.0 in .1 5.1 cm Dimensions (H x W x D) RA-ENC1 6.3 x 9.8 x 2.0 in (16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in (30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in (45.0 x 24.9 x 5.1 cm) Note: Allow approximately 2 inches (50 cm) clearance on both sides of the enclosure, to permit inserting and removing the key, and opening the door through 90 degrees. Page 3 of 4 DATA SHEET E85005-0128 Not to be used for installation purposes. Issue 1.1 CDWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier All rights reserved. Specifications RLCD-C RLCD RLED-C RLED24 Operating voltage 24 VDC, continuous. Standby current 99 mA 98 mA 28 mA 6 mA Alarm current 115 mA 113 mA 62 mA 34 mA RS-485 communications Class A or Class B, 9600 baud Data wiring 18 to 14 AWG (1.0 to 2.5 sq mm) twisted pair (6 twists per foot minimum). Maximum wire run is 4,000 ft. (1,219 m) Remote key switch circuit 5 VDC at 1 mA, power -limited, unsupervised Ground fault impedance 0 Power wiring 18 to 14 AWG (1.0 to 2.5 sq. mm) Display area 4 lines of 20 characters each Dimensions (H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in. (14.3 x 21.4 x 3.8 cm) Mounting North American 4-inch square electrical box or listed enclosure Agency Listing UL, ULC Operating environment Temperature: 32 to 120°F (0 to 49°C) Humidity: 0 to 93% RH, noncondensing at 90°F (32°C) Ordering Information Part Description Remote Annunciators RLCD LCD text annunciator without common controls. English. RLCD-R LCD text annunciator without common controls. English. Red. RLCDF LCD text annunciator without common controls. French. RLCD-C LCD text annunciator with common controls. English. RLCD-CR LCD text annunciator with common controls. English. Red. RLCD-CF LCD text annunciator with common controls. French. RLED-C 16-pair LED zone annunciator with common controls. English. BLED-CR 16-pair LED zone annunciator with common controls. English. Red. BLED-CF 16-pair LED zone annunciator with common controls. French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24-pair LED zone expander with expander cable and zone card insert. Red. Enclosures RA-ENC1 One -position enclosure for Remote Annunciator. RA-ENC2 Two -position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three -position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box - for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver, provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches. Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls (Lock/ Unlock). 27193-16 Electrical box, surface mount, white, single -gang, for RKEY. Page 4 of 4 DATA SHEET E85005-0128 Not to be used for installation purposes. Issue 1.1 59 T O E 12E?L0V-"L// GT�S ,VWW ISAE Cu. SURGE PROTECTIVE DEVICE Install Date_/_ LED ON In Service Dt_/_ Insspp Dt_/_ Dt_/_ Insp Dt_/_ i11111111111 FlRE _ FA I ti _ ALARM J '98V1tl 16 FAQ FIRE ALARM till � e� Standard Features: • Available in 120 VAC • UL Listed 1449 3rd Edition Type 2 & 3 2X to open circuit breaker @5000A • Includes lockout & labels per NFPA 72 2013 10.6.5.2 • Surface or conduit mounting • Diagnostic indicator light • Self restoring • 3 Wire device (18" length) � n Made I�n �- Uses UL Recognized Components Hybrid Surge Protection Device Safety and performance is what Eclips is all about. While there are many varying criteria to be considered for surge protective devices (SPD), if the design engineer neglects the importance there can be serious implications for the client and equipment. Every piece of electrical equipment is designed to operate at a specified nominal voltage. Typically equipment is designed to handle minor variations. However external sources such as lightning, motors, and short circuits cause wild and damaging variations. Critical systems wired to your electrical service like Fire Alarm Control Panels (FACP), Mass Notification systems, amplifiers, motors, pumps (HVAC), power boosters and many more must require appropriate levels surge protection. The E120 series is an ideal choice for your 120V AC applications. because it has the robustness not only to absorb a spike, but to clamp long enough to trip the branch circuit breaker and still be functional for additional surges. The number one cause of destruction, degradation and down- time of critical electrical equipment is from power surges and lightning strikes. The E120V-GT device is an ideal solution to protect equip- ment. UL listed it maintains system integrity and protects against transients introduced into / onto electrical lines via poor atmospheric and utility conditions as well as internally gener- ated inductive loads and transient TVSS. It reduces system downtime associated with power surges and lightning strikes. Prevents destruction and degradation of electrical components in the system. Fix your nuisance and non -billable service calls as a result of transients and poor power quality and show your customer you care about system integrity. ISO 9001 REGISTERED COMPANY ARM oww"Am- Space Age Electronics, Inc. www.lSAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 LT10629 Rev.5 1/2 No Excuses, Just Solutions! /NSPACEAGE LECTRONICS, INC. Specifications: All 120volt AC equipment will have Transient Voltage Surge Suppression (TVSS) protection manu- factured by Space Age Electronics, Inc., part number E120V-GT ECLIPS Brand. The Unit shall be UL listed to standard 1449 rev 3. The unit will be labeled clearly with indelible ink. Mounting can be con- duit mounted with a 3/4" pipe threaded nipple to secure in panel, or surface panel mount with 2 external mounting holes. The unit shall have thermal fuses to protect against fire in short circuit conditions. The E120V will have 18" long, 14 gauge wires (3x) ground wire must be green. The enclosure will be a non dielectric material UL94 QMFZ2/8 grade material providing UV protection. The unit shall provide visual indication (LED) that unit is protecting and functioning. Specifications - Performance: Short Circuit Current Rating (SCCR) Maximum Surge Current (8x20ps) Enclosure Material Energy Dissipation Joules VPR=700(L — N) 700 (L — G) 600 (N — G) Capacitance : Clamping Response Time: Current : Max Operating Voltage (MCOV) : Clamping Voltage: Design Operation Indicators Surviveability 5KA 25,000 Amps UL94 QMFZ2/8 (green) 500 Joules < 2,000 pf < 5 nanoseconds Non -Load Bearing 140 volts AC, 50/60 Hz 230 Volts RMS Thermally Fused Hybrid LED UL rated X2 @5000 Amps to open Series external circuit breaker Specifications - Compliance: Specifications - Operating: Service Voltage : 120 Single Phase Circuits Protected : L-N L-G N-G Connection Type : Hardwired Installation Configuration : Parallel Specifications - Physical: Weight: 5.2oz Dimensions : 2.75" x 1.55" x 4" long Operation Temperature : -40 to +851 C Mechanical Drav UL Listed: 1449 Third Edition - VZCA 1.5" File Number: E319370 Vol. 1 Sec. 1 1 Wiring Diagram: +---2.6" Breaker panel N ° w ° Protected Device O o ® EM L O O ® ® ® ® N ® ® m IOU-] ® m eLL e N G O mmeeme G O 1 O _ O Space Age Electronics, Inc. www.lSAE.com 800.486.1723 Toll Free 508.485.0966 Local 508.485.4740 Fax No Excuses, Just Solutions! Ordering Information: Part # Description E120V-GT 120V Hybrid Surge Protective Device ELOCK-FA Circuit Lockout Kit This document is subject to change without notice, see doc # ED0479 for legal disclaimer LT10629 Rev.5 2/2 EDWARDS° Catalog ► Intelligent Initiating Devices WARDB LIFE SAFETY 7 INCIDENT MANAGEMENT Intelligent Smoke Detector SIGH-OSD Overview The Signature Optica Series SIGA-OSD smoke detector brings advanced optical sensing technology to a practical design that increases efficiency, saves installation time, cuts costs, and extends life -safety and property -protection capabilities. Continuous self -diagnostics ensure reliability over the long haul, while environmental compensation helps reduce maintenance costs. Like all Signature Optica Series detectors, the SIGA-OSD is an intelligent device that gathers analog information from multiple optical sensors, converting this data into digital signals. Utilizing dual optical wavelengths combined with multiple detection angles, the SIGA-OSD differentiates particles that are not representative of actual smoke. Particle data is input into digital filters which feed a series of ratios removing signal patterns that are typical of nuisance sources, thus reducing unwanted alarms. To make an alarm decision, the detector's on -board microprocessor measures and analyzes all optical sensor readings and compares this information to preprogrammed settings. FM WON now` `, naaaoveo / UL UL 288FE4.g 7272-1657: 0511 Standard Features • Multi -criteria optical smoke -sensing technology • Wide 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) smoke obscuration • Uses Existing Wiring • Integrated nuisance rejection reducing unwanted alarms from general cooking particulates • Listed to UL 268 7th edition • Automatic Device Mapping • Up To 250 Total Signature Addresses Per Loop • Two Levels of Environmental Compensation • Two Levels of Dirty Detector Warning • Twenty Pre -Alarm Settings • Five Sensitivity Settings • Non -Volatile Memory • Electronic Addressing • Automatic Day/Night Sensitivity Adjustment • Bicolor (Green/Red) Status LED • Standard, Relay, Fault Isolator, and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Note: Some features described here may not be supported by all control systems. Check your control panel's Installation and Operation Guide for details. Page 1 of 4 DATA SHEET E85001-1001 Not to be used for installation purposes. Issue 1.5 Application Testing & Maintenance The SIGA-OSD detects particles from a wide range of combustion sources and will trigger an alarm when smoke density in the chamber reaches preprogrammed level. Thanks to its high- performance reflective -response technology, the smoke sensor responds quickly and reliably to a wide range of fire types, including both fast- and slow -burning fires fueled by combustibles typically found in modern multi -use buildings. Compatibility The SIGA-OSD detector is compatible only with control panels using a Signature Loop controller. Installation Signature Series detectors mount to North American 1-gang boxes, 3-1/2 inch or 4 inch octagon boxes, and to 4 inch square Self-locking tab electrical boxes 1-1/2 inches (38 mm) deep. They mount to European BESA and 1-gang boxes with 60.3 mm fixing LED Indicator centers. See mounting base installation and wiring for more information. Sensing and reporting technology The microprocessor in each detector provides additional benefits — Self -diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self -diagnostics and History Log - Each Signature Series detector constantly runs self -checks to provide important maintenance information. The results of the self -check are automatically updated and permanently stored in the detector's non-volatile memory Automatic Device Mapping - The loop controller learns where each device's serial number address is installed relative to other devices on the circuit. The mapping feature provides supervision of each device's installed location to prevent a detector from being reinstalled (after cleaning, etc.) in a different location from where it was originally. Fast Stable Communication - On -board intelligence means less information needs to be sent between the detector and the loop controller. Other than regular supervisory polling response, the detector only needs to communicate with the loop controller when it has something new to report. Each detector automatically identifies when it is dirty or defective and causes a "dirty detector" message. The detector's sensitivity measurement can also be transmitted to the loop controller. A sensitivity report may be printed to satisfy NFPA sensitivity measurements, which must be conducted at the end of the first year and every two years thereafter. The user-friendly maintenance program shows the current state of each detector and other pertinent messages. Single detectors may be turned off temporarily from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Accessories Detector mounting bases have wiring terminals that are accessible from the "room -side" after mounting the base to the electrical box. The bases mount to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 1 t/2 inches (38 mm) deep. They also mount to European BESA and 1-gang boxes with 60.3 mm fixing centers. The SIGA-SB4, SIGA-RB4, and SIGA-I134 mount to North American 4 inch sq. electrical boxes in addition to the above boxes. They include the SIGA-TS4 Trim Skirt, which is used to cover the "mounting ears" on the base. The SIGA-AB4G mounts to a 4 inch square box only. I„ SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED Audible Base Standard Base Isolator Base Relay Base Remote LED Remote LED SIGA-LED - The remote LED connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American size 1-gang plastic faceplate with a white finish and red alarm LED. SIGA-TS4 Trim Skirt - Supplied with 4 inch bases, it can also be ordered separately to use with the other bases to help hide surface imperfections not covered by the smaller bases. Sounder Bases - Signature Series sounder bases are designed for use where localized- or group -alarm signaling is required. • SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors. They are not intended for use with combination carbon monoxide detectors in Fire -plus -CO mode. • SIGA-AB4GT bases provide sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. • SIGA-AB4G-LF bases provide 520 Hz low frequency sounder capability to Signature Series smoke and heat detectors, as well as carbon monoxide detectors when used with a SIGA-TCDR Temporal Pattern Generator. The SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2 of 4 DATA SHEET E85001-1001 Not to be used for installation purposes. Issue 1.5 Typical Wiring The detector mounting bases accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.5mm2), and #12 AWG (2.5mm2) wire sizes Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. Standard Detector Base, SIGA-SB, SIGA-SB4 This is the basic mounting base for the EDWARDS Signature Series detectors. TMaxresistance The SIGA-LED Remote LED pr wire ustnotexceed is supported by this base. ioonms Term Description 1 Not Used 2 DATA IN/OUT 3 Not Used 4 DATA IN (-) DATA IN (-) O a o O DATA OUT 1-) 4 Remote LED (-) 5 Remote LED (+) 6 Not Used DATA IN 1+) DATA OUT 1+) 7 DATA OUT (-) From Signature Controller To Next Device or Previous Device Isolator Detector Base, SIGA-IB, SIGA-I134 This base includes a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. The isolator operates as follows: - a short on the line causes all isolators to open within 23 n - at 10 msec intervals, beginni on one side of the Class A circuit nearest the loop controller, the isolators DX close to provide the next isolator down DAIS II, iT/ the line with power. From Signature Controller or Previous Device - when the isolator next to the short closes, it reopens within 10 msec. The process repeats beginning on the other side of the loop controller. Relay Detector Base, SIGA-RB, SIGA-RB4 This base includes a relay. Normally -Open or Normally - Closed operation is selected during installation. The dry contact is rated for 1 amp (pilot duty) @ 30 Vdc. The relay's position is supervised to avoid accidentally jarring it out of position. The SIGA-RB can be operated as a control relay if programmed to do so at the control panel. The relay base does not support the SIGA-LED Remote LED. DAL Audible Sounder Bases, Fire Mode A134GT, A134G, AB4G-LF sounder bases SIGA-AB4G, SIGA-AB4G-LF: Volume Setting Default = High Cut/remove jumper for low dB 24 Vdc in From power supply or previous base + Data in _ From Signature Controller or previous device + Jumper cuts QD (in DATA- DATA- DATA+ SIG+ SIG- OUT IN IN/OUT Output Mode Default = Fire Cut/remove jumper for Fire plus CO SIGA-AB4G: Tone Setting Default = Temporal Cut/remove jumper for Steady - 24 Vdc out + To next base or EOL relay Data out to next Signature device Warnings & Cautions • This detector does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. • This detector does not sense fires in areas where smoke cannot reach the detector. Smoke from fires in walls, OUT c) roofs, or on the opposite side of closed doors may not reach the detector. OUT (+) To Next Device Term Description 1 Not Used 2 DATA IN/OUT (+) 3 DATA IN (-) 4 Not Used 5 Not Used 6 DATA OUT (-) 7 Not Used OUT(-) DATA IN (+) DATA OUT (+) From Signature Controller To Next Device or Previous Device Term Description 1 Normally -Open CONTACT RATING 2 DATA IN/OUT (+) 1.0 Amp @ 30 VDC 3 Common (Pilot Duty) 4 5 6 7 DATA IN (-) Not Used Normally -Closed DATA OUT (-) • In Canada, install according to CAN/ULC-S524 Standard for the Installation of Fire Alarm Systems, CSA C22.1 Canadian Electrical Code, and the local authority having jurisdiction. Page 3 of 4 DATA SHEET E85001-1001 Not to be used for installation purposes. Issue 1.5 CDWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2023 Carrier All rights reserved. Dimensions Q -4 Specifications 2316 LMIVd.LOJO ]■I■I IIFI 4 IN Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 45 pA Smoke Sensitivity Range UL/ULC: 0.5 to 4.36 %/ft. (1.6 to 13.6 %/m) obscuration Vibration level 10 to 35 Hz, with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min (0 to 20 m/s) Wall mounting 12 in. (305 mm) max. from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000, Testifire 2000 Operating environment 32 to 120°F (0 to 49°C), 0 to 93% RH, noncondensing Construction High Impact Engineering Polymer, White Storage temperature -4 to 140°F (-20 to 60oC) Environmental compensation Automatic Agency Listings CAN/ULC-S529, UL 268-7, UL 268A, CSFM Ordering Information Catalog Description Number Ship Wt. Ibs (kg) SIGA-OSD Intelligent Optical Smoke Detector 0.4 (0.16) SIGA-OSD-NL Intelligent Optical Smoke Detector, no visible logo 0.4 (0.16) Accessories SIGA-SB Detector Mounting Base - Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2 (.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator, c/w Trim Skirt SIGA-LED Remote Alarm LED (not for EN54 applications) SIGA-AB4G Audible (Sounder) Base for Fire Detectors 0.3 (0.15) SIGA-AB4G-LF Low Frequency Audible (Sounder) Base for CO and/or Fire Detectors 0.3 (0.15) SIGA-AB4GT Audible (Sounder) Base for CO and/or Fire Detectors 0.3 (0.15) SIGA-TS4 Trim Skirt (supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt - (optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0 (1.4) SIGA-RTA Detector Removal Tool Page 4 of 4 DATA SHEET E85001-1001 Not to be used for installation purposes. Issue 1.5 EDWARDS° Catalog ► Intelligent Initiating E WARDB W1, LIFE SAFETY 7 INCIDENT MANAGEMENT Manual Pull Stations SIGA-270, SIGA-270P, SIGA-278 Overview The SIGA-270 and SIGA-278 series Manual Pull Stations are part of EDWARDS's Signature Series system. The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape. They are made from die-cast zinc and finished with red epoxy powder - coat paint complemented by aluminum colored stripes and mark- ings. With positive pull -lever operation, one pull on the station handle breaks the glass rod and turns in a positive alarm, ensuring protection plus fool -proof operation. Presignal models (SIGA-270P) are equipped with a general alarm (GA) keyswitch for applications where two stage operation is required. The up -front highly visible glass rod discourages tampering, but is not required for proper operation. EDWARDS's double action single stage SIGA-278 station is a contemporary style manual station made from durable red colored lexan. To initiate an alarm, first lift the upper door marked "LIFT THEN PULL HANDLE", then pull the alarm handle. Standard Features Note: Some features described here may not be supported by all control sys- tems. Check your control panel's Installation and Operation Guide for details. • Traditional familiar appearance SIGA-270 models feature our familiar teardrop design with simple positive pull action and sturdy die-cast metal body. • One stage (GA), two stage (pre -signal), and double action models SIGA-270 models are available for one or two stage alarm systems. The single stage double action SIGA-278 features a rugged Lexan housing with keyed reset mechanism. SIGA-278 k A L UC MEA Fm 7150-1657: 0129 S2318 • Break glass operation An up -front visible glass rod on the SIGA-270 discourages tampering. • Intelligent device with integral microprocessor All decisions are made at the station allowing lower com- munication speed while substantially improving control panel response time. Less sensitive to line noise and loop wiring properties; twisted or shielded wire is not required. • ADA Compliant Meets ADA requirements for manual pull stations. • Electronic Addressing with Non-volatile memory Permanently stores programmable address, serial number, type of device, and job number. Automatically updates historic information including hours of operation, last maintenance date, number of alarms and troubles, and time and date of last alarm. • Automatic device mapping Each station transmits wiring information to the loop control- ler regarding its location with respect to other devices on the circuit. • Diagnostic LEDs Status LEDs; flashing GREEN shows normal polling; flashing RED shows alarm state. • Designed for high ambient temperature operation Install in ambient temperatures up to 120 °F (49'Q. Page 1 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.1 Application The operating characteristics of the fire alarm stations are deter- mined by their sub -type code or "Personality Code". NORMALLY - OPEN ALARM - LATCHING (Pesonality Code 1) is assigned by the factory; no user configuration is required. The device is configured for Class B IDC operation. An ALARM signal is sent to the loop controller when the station's pull lever is operated. The alarm con- dition is latched at the station. Compatibility Signature Series manual stations are compatible only with ED- WARDS's Signature Loop Controller. Warnings & Cautions This device will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Typical Wiring The fire alarm station's terminal block accepts #18 AWG (0.75mm2) to #12 AWG (2.5mm2) wire sizes. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Wiring Notes A Refer to Signature Loop Controller manual for maximum wire distance. 2. All wiring is power limited and supervised. REAR VIEW of 278 e o O 0 TB2 8 7 Red LED I Green LED (Alarm/Active) Oo 4 i (Normal) 4 3 2 1 O TBl Testing & Maintenance To test (or reset) the station simply open the station and operate DATA""' DATA OUT (+)lr the exposed switch. The SIGA-270 series are opened with a tool; DATA No DATA OUT the SIGA-278 requires the key which is supplied with that station. From signature controller Y To Next Device or Previous Device A The station's automatic self -diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Figure 4. Single Stage Systems REAR VIEW of 270P, 270PB OO Red LED i iiiOo (Alarm/Active) _ _ 00 TBl CIU (IU CIU U O O 0 o im - Green LED (Normal) j( DATA IN (+) DATA OUT (+) l DATA IN (-) DATA OUT (-) From Signature Controller Y To Next Device or Previous Device n Figure 5. Two Stage Systems Page 2 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.1 Installation Single -stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch (64 mm) deep 1-gang boxes. Two stage presignal (270P) models require 1 t/2 inch (38 mm) deep 4-inch square boxes with 1-gang, 1/2-inch raised covers. Openings must be angular. Rounded openings are not acceptable. Recommended box: Steel City Model 52-C-13; in Canada, use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. EDWARDS recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on -board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Compatible Electrical Box 1-1 _ Back Plate _Toggle Switch Key -Latch Cover Releasle i It y _ Q O - Glass Rod OPEN • L/J Figure 1. SIGA-278 installation Cover Release Figure 3. SIGA-270P, SIGC-270PB installation Compatible Electrical Box Cover Release Screw a o o O . Back l 0 Plate Toggle c Switch N ORMpI o Q ® Glass Rod q� \ Release Lever Figure 2. SIGA-270, SIGC-270F, SIGC-270B installation Page 3 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.1 CDWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier All rights reserved. Specifications SIGA-270, SIGC- SIGA-270P, Catalog Number 270F, SIGC-270B SIGC-270PB SIGA-278 Description Single Action Single Action -Two Double Action - One Stage Stage (Presignal) - One Stage Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Operating Current Standby = 250pA Standby = 396NA Standby = 250pA Activated = 400pA Activated = 68OpA Activated = 400pA Construction & Finish Diecast Zinc - Red Epoxy Lexan - Red with with aluminum markings white markings Type Code Factory Set Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Storage and Operating Operating Temperature:o320F to 120OF (0°C to 49°C) Environment o Storage Temperature: -4 F to 140 F (-20 C to 60 C) Humidity: 0 to 93 /o RH LED Operation On -board Green LED - Flashes when polled On -board Red LED - Flashes w hen in alarm Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC (note 1), MEA, CSFM, FM Note: SIGC-27OF, SIGC-270B and SIGC-270PB are ULC listed only. Suffix "F" indicates French markings. Suffix `B" indicates English/French biling ual markings. Ordering Information Catalog Ship Wt. Number Description Ibs (kg) SIGA-270 One Stage Fire Alarm Station, English Markings - UUULC Listed SIGC-27OF One Stage Fire Alarm Station, French Markings - ULC Listed SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed SIGA-270P Two Stage (Presignal) Fire Alarm Station, English Markings - UUULC Listed 1 (0.5) SIGC- Two Stage (Presignal) Fire Alarm Station, French/English Markings 270PB - ULC Listed SIGA-278 Double Action (One Stage) Fire Alarm Station, English Markings - UUULC Listed Accessories 32997 GA Key w/Tag - for pre -signal station (CANADA ONLY) 276-K2 GA Key - for pre -signal station (USA ONLY) 276-K1 Station Reset Key, Supplied with all Key Reset Stations 0.1 (.05) 27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY) 270-GLR 20 Glass Rods - for SIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods - for SIGA-278 series 276B-RSB Surface Mount Box, Red - for SIGA pull stations 1 (0.6) Page 4 of 4 DATA SHEET E85001-0279 Not to be used for installation purposes. Issue 1.1 I Er. WARDB LIFE SAFETY 7 INCIDENT MANAGEMENT Input Modules SIGA-CT1, SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 SIGA-MCT2 Overview The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Temperature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Input Modules are intelligent analog addressable devices used to connect one or two Class B normally -open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (IDC). The actual function of these modules is determined by the "personality code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configuration. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on -board microprocessor analyzes the signal and decides whether or not to input an alarm. The SIGA-CT1, SIGA-CT1 HT and SIGA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate 1/0 and data loop connections are made to each module. The SIGA-CT1 HT module operates at an expanded temperature range of 32 OF to 158 OF (0 °C to 70 °C) for those applications requiring more extreme environmental temperature variation. The SIGA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the SIGA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all U10 modules. Two- and six -module U10 motherboards are available. All wiring connections are made to terminal blocks on the motherboard. U10 assemblies may be mounted in EDWARDS enclosures. V r SIGA-CT1/2 EDWARDS° Catalog ► Intelligent Input -Output AR' 8 3 h U� a.� MEA � 7300-165LC , 0121 53424 Standard Features • Multiple applications Including Alarm, Alarm with delayed latching (retard) for waterflow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the module through the loop controller. • SIGA-CT1 HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. • Plug-in (U10) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. • Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. • Electronic addressing Programmable addresses are downloaded from the loop controller, a PC, or the SIGA-PRO Signature Program/Service Tool. There are no switches or dials to set. • Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1.1 Signature Series Overview The Signature Series intelligent analog -addressable system from EDWARDS Security is an entire family of multi -sensor detectors and mounting bases, multiple -function input and output modules, network and non -network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits — Self - diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self -diagnostics and History Log — Each Signature Series device constantly runs self -checks to provide important maintenance information. The results of the self -check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/ Service Tool. Automatic Device Mapping —The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as -built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. Installation SIGA-CTi, SIGA-CTi HT and SIGA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. / Compatible electrical box Wall plate, white (1-gang) • •� 1 'a. •• Q Status LEDs,` e, ,`� LED viewing ports • �'. o, SIGA-MCT2: mount the UIO motherboard inside a suitable ED- WARDS enclosure with screws and washers provided. Plug the SIGA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard --------------- ---- ..._ Plug-in (UIO) Module -- -- �--mil Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on -board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is determined by their sub -type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the SIGA-CT1. Two personality codes can be assigned to the SIGA-CT2/MCT2. Codes 1, 2, 3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY -OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY -OPEN ALARM - DELAYED LATCHING (Personality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally -open dry contact initiating devices such as Waterflow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY -OPEN ACTIVE - NON -LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally -open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY -OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is latched at the module. Page 2 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1.1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1.50mm2), and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.Omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR Q1 A2 Q4 Style Red I (Alarm/F {DATA IN (+) DATA IN(-) From SignatL or Previous Device Typical N.O. Initiating Device A SIGA-CT1, SIGA-CT1 HT #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) 4,000 ft (1,219 m) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) Typical N.O. Initiating Device N I INPUT INPUT2 CIE TB2 ®®®® UL/ULC Listed Style B Class B 47K(I FOIL UL/ULC Listed y ( ) 807 605 UL/ULC Listed 47KQ EOL Qj Q • • • 47KO EOL Green LED Red LED Green LED (Normal) (Alarm/Active) 4 3O2 1O (Normal) TB1 {( DATA IN (+) DATA OUT (+) ( DATA IN (-) DATA OUT (-) From Signature Controller To Next Device 'e or Previous Device 0 3 SIGA-CT2 Typical NO Initiating Devi e NOTES 1Q Maximum 25 Ohm resistance per wire. 2Q Maximum #12 AWG (2.5 mm2) wire; Minimum #18 AWG (0.75 mm2). 30 Refer to Signature controller installation sheet for wiring specifications. ® Maximum 10 Vdc @ 350 pA 50 The SIGA-UI06R and the SIGA-UI02R do not come with TB14. 6 All wiring is supervised and power -limited. 7 These modules will not support 2-wire smoke detectors. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility These modules are part of EDWARDS'S Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. "41KW EOL S ITI ITI ITI Input2 I I Input l Data In + Signature Data Circuit Data Out + I y Ty I I I uuuLcu'u- stee �7TC J���74 1 2 A MCT2 MIRI series motherboard ®A 3 5 i TB14 No coane ions required for MCT2 \ Otthuaodules may require n. ons. Green LEDLED(Acti. II T6151 Red LED IActivel 123A No connections orjumper settings required for MCT2. SIGA-MCT2 Page 3 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1.1 CDWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier All rights reserved. Specifications Catalog Number SIGA-CTi HT I SIGA-CTi SIGA-CT2 I SIGA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub -types (personality codes) are available 49 (factory set) Four sub -types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 400pA Standby = 396pA; Activated = 680pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one -gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one -gang covers and SIGA-MP mounting plates U102R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) 32°F to 120°F (0°C to 49°C) Storage Environment -4°F to 140°F (-20oC to 60oC); Humidity: 0 to 93% RH LED Operation On -board Green LED - Flashes when polled; On -board Red LED - Flashes when in alarm/active. Compatibility Use with Signature Loop Controller Agency Listings UL, ULC, MEA, CSFM Ordering Information Catalog Ship Wt. Number Description Ibs k ( g) SIGA-CT1 Single Input Module — UL/ULC Listed 0.4 (0.15) SIGA-CT1 HT Single Input Module High Temperature Operation UL/ULC Listed 0.4 (0.15) SIGA-CT2 Dual Input Module — UL/ULC Listed 0.4 (0.15) SIGA-MCT2 Dual Input Plug-in (UIO) Module — UL, ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1.0 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) SIGA-U102R Universal Input -Output Module Board w/Riser Inputs 0.32 (0.15) — Two Module Positions SIGA-U106R Universal Input -Output Module Board w/Riser Inputs 0.62 (0.28) — Six Module Positions SIGA-U106 Universal Input -Output Module Board — Six Module Positions 0.56 (0.25) MFC-A Multifunction Fire Cabinet — Red, supports Signature Module 7.0 (3.1) Mounting Plates SIGA-MB4 Transponder Mounting Bracket (allows for mounting 0.4 (0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 4 of 4 DATA SHEET E85001-0241 Not to be used for installation purposes. Issue 1.1 EDWARDS° Catalog ► Intelligent Input/Output E WARDB W1, LIFE SAFETY 7 INCIDENT MANAGEMENT Control Relay Modules SIGA-CR, SIGA-MCR, SIGA- CRR, SIGA-MCRR Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The SIGA-CR/MCR Control Relay Module provides a Form "C" dry relay contact to control external appliances such as door closers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on -board microprocessor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the SIGA-CR/MCR relay activates the normally open or normally -closed contact. The SIGA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of SIGA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the SIGA-CRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. Standard -mount versions (SIGA-CR and SIGA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is required. Separate 1/0 and data loop connections are made to each module. Plug-in UIO versions (SIGA-MCR and SIGA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six -module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in EDWARDS enclosures. An e SIGA-MCR Standard Features SIGA-CR ge FM 7300-1657: MEA ULC o .0 0121 S3424 • Provides one no/nc contact (SIGA-CR/MCR) Form "C" dry relay contact can be used to control external appliances such as door closers, fans, dampers etc. • Allows group operation of sounder bases The SIGA-CRR/MCRR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop. • Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. • Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. • Electronic addressing Programmable addresses are downloaded from the loop controller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. • Intelligent device with microprocessor All decisions are made at the module to allow lower communication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Page 1 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1.1 Installation Application SIGA-CR and SIGA-CRR: modules mount to North American 21/2 inch (64 mm) deep 1-gang boxes and 1 t/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. 2 0 SIGA-MCR and SIGA-MCRR: mount the UIO motherboard inside a suitable EDWARDS enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UIO Motherboard --------------- Plug-in (UIO) Module Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically addresses each module, saving valuable time during system commissioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on -board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. EDWARDS recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. The operation of Signature Series control relays is determined by their sub -type code or "Personality Code." Personality Code 8: CONTROL RELAY (SIGA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form "C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Vac (or 0.25A @ 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configuration is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (SIGA-CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility These modules are part of EDWARDS's Signature Series intelligent processing and control platform. They are compatible with EST3, EST3X and iO Series control panels. Warnings & Cautions This module will not operate without electrical power. As fires frequently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self -diagnosis identifies when it is defective and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other pertinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Page 2 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1.1 Typical Wiring Modules will accept 418 AWG (0.75mm2), 416 (1.Omm2), 414 AWG (1.50mM2) and 412 AWG (2.5mm2) wire sizes. Note: Sizes 416 AWG (1.Omm2) and 918 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. DATA IN (+) DATA I N (-) From Signature or Previous L— 1- n Data In + + Data Out_ Green Re( Normally- Normally - Open Common Closed Green LED (Normal) -A OUT (+) -A OUT() text Device ❑e SIGA-CR Control Relay Normally Open Common Normally Closed A 1234 No connections required for MCR. Other modules may require connections. SIGA-MCR Control Relay Notes Al Refer to Signature Loop Controller Installation Sheet for wiring specifications. Q2 NFPA 72 requires that the SIGA-CR/SIGA-MCR be installed in the same room as the device it is controlling. This requirement may not apply in all markets. Check with your local AHJ for details. Q The SIGA-UI06R and the SIGA-UI02R do not come with TB14. ® The SIGA-UI06 does not come with TB8 through TB13. 50 Supervised and power -limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power -limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 0 Maximum #12 AWG (2.5mm2) wire. Min. #18 (0.75mm2). No connections required for MCR. Other modules may require connections. Page 3 of 6 DATA s H E E l E85001-0239 Not to be used for installa, Issue 1.1 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1.Omm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Listed 24 VDC Nominal Powel Suppl) Signature Controller SIGA-CRR Schematic Powerin Power Out Polarity Reverses When Activated 5 4 3 2 1 AB4G AB4G AB4G Audible Base Audible Base Audible Base sounder base SIGA-MCRR SIGA-MCRR Schematic Power In Power Out Polarty reverses t when activated. Notes QRefer to the Signature controller installation sheet for wiring. 0 One Pair of Wires (24 Vdc power). 30 One Pair of Wires (Signature Data). Single Wire (24 Vdc power). 0 The SIGA-UI06R and the SIGA-UI02R do not come with TB14. A The SIGA-UI06 does not come with TB8 through T613. 0 Supervised and power -limited. ® If the source is nonpower-limited, maintain a space of 1 /4 inch from power -limited wiring or use FPL, FPLP, `PLR, or an equivalent in accordance with the National Electrical Code. 9 Maximum #12 AWG (2.5 mm2) wire; Minimum #18 AWG (0.75 mm2 ). 10 End -of -Line Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be "T-tapped." 7 1 Data Out + Signature 4 Data 3 Circuit 1 TB7 + /Data In Green LED (Normal) Red LED (Active) Optional MCRR or MCR for disabling/disconnecting an audible base. Signature Data Data Out + Circuit F O 6254A-003 Z Z EOL Relay Audible O _ required for Bases = = ± supevision 7 7i 0 o A II o O • UL/ULC Listed + 24 Vdc power supply or — } — 1234 \1234 u �� �' Green LED )Normal) FFFIII 6` 3 Red LED (Active) ti 2 1 No connections required for Tess MCRR. Other modules may 1 2 3 4 o require connections. For normal operation CTl For General Fire Alarm Operation � � 4 3 2 1 MCRR UIOIRI series motherboard 4 3 i Q No connections required for T814 6 MCRR. Other modules may require connections. AVA No connections required for MCRR. Other modules may require connections. Page 4 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1.1 Specifications Catalog Number SIGA-CR SIGA-MCR Control Relay SIGA-CRR SIGA-MCRR Polarity Reversal Relay Description Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address Operating Current Standby = 75 pA Activated = 75 pA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C, 2 Amps @ 24 Vdc (pilot duty), 0.5 Amps @ 120 Vac and 0.25 Amps @ 220 Vac (220 Vac is non-UL) Not rated for capacitive loads. Mounting North American 21/2 inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates Plugs into U102R, U106R or U106 Motherboards North American 21/2 inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and SIGA- MP mounting plates Plugs into U102R, U106R or U106 Motherboards Construction & Finish High Impact Engineering Polymer Storage and Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140°F (-20oC to 60°C) Humidity: 0 to 93% RH LED Operation On -board Green LED - Flashes when polled On -board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings IUL, ULC, CSFM, MEA Ordering Information Catalog Number Description Ship Weight - Ibs (kg) SIGA-CR Control Relay Module (Standard Mount) 0.4 (0.15) SIGA-MCR Control Relay Module (UIO Mount) 0.18 (0.08) SIGA-CRR Polarity Reversal Relay Module (Standard Mount) 0.4 (0.15) SIGA-MCRR Polarity Reversal Relay Module (UIO Mount) 0.18 (0.08) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1 (0.6) 27193-16 Surface Mount Box - White, 1-gang 1 (0.6) SIGA-U102R Universal Input -Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) SIGA-U106R Universal Input -Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) SIGA-U106 Universal Input -Output Module Board - Six Module Positions 0.56 (0.25) SIGA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1) SIGA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) SIGA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 5 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1.1 CDWARDS LIFE SAFETY & INCIDENT MANAGEMENT Contact us Phone: 800-655-4497 (Option 4) Email: edwards.fire@carrier.com Website: edwardsfiresafety.com 8985 Town Center Pkwy Bradenton, FL 34202 © 2020 Carrier All rights reserved. Signature Series Overview The Signature Series intelligent analog -addressable system from EDWARDS is an entire family of multi -sensor detectors and mounting bases, multiple -function input and output modules, network and non -network control panels, and user-friendly maintenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature device measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits — Self - diagnostics and History Log, Automatic Device Mapping, and Fast, Stable Communication. Self -diagnostics and History Log — Each Signature Series device constantly runs self - checks to provide important maintenance information. The results of the self -check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signature Program/Service Tool. The information stored in device memory includes: • Device serial number, address, and type • Time and date of last alarm • Most recent trouble code logged by the detector — 32 possible trouble codes may be used to diagnose faults. Automatic Device Mapping —The Signature Data Controller (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or "as -built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as -built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: • Unexpected additional device addresses • Missing device addresses • Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configuration and are indicated during device mapping. Page 6 of 6 DATA SHEET E85001-0239 Not to be used for installation purposes. Issue 1.1 ACE SRD ACE-11 S1lstem Record Documents f BY SPACE AGE ELECTRONICS u� LISTED FEATURES • 18 gauge cold rolled steel construction with red powder coat and white lettering • Dimensions are 12" wide x 13" tall and 2 1 /4" deep • Stainless steel piano hinge • Two key ring hooks to hold system keys Store important system documents in a secure location with a cabinet built specifically to meet the requirements of NFPA 72 7.7.2.4. The number one goal at Space Age is to manufacture code compliant solutions, and the SRD is just that. NFPA 72 7.7.2.1 states, "With every new system, a documentation cabinet shall be installed at the system control unit or other approved location at the protected premises." The SRD includes our innovative 8GB flash drive slide tab that allows the user to select a USB-C or Micro USB connector to access records electronically (See NFPA 72 7.5.6.7). SPECIFICATIONS The SRD System Record Documents Box shall be UL Listed, constructed of 18 gauge cold rolled steel. It shall have a powder coat finish. The cover shall be permanently screed with 1" high lettering "SYSTEM RECORD DOCUMENTS" with white indelible ink. The access door shall be locked with a 3/4" barrel lock and there will be a 12" stainless steel piano hinge. The SRD will have a minimum of 8 gigabyte digital flash memory drive with a slide tab that allows user to select USB-C or Micro USB connector for uploading and downloading information. The • Business card holder for key enclosure will supply 4 mounting holes. Inside will contacts accommodate standard 8 1/2" x 11" manuals and document • Slide tab allows user to records. A legend sheet will be attached to the door for system select USB-C or Micro USB required documentation, key contacts and system information. connector to download The enclosure shall also provide 2 key ring holders with a from 8GB digital flash location to mount standard business cards for key contact memory personnel. • DCD Computer Desk Kit (sold separately) holds CUSTOM COLORS AND BRANDING AVAILABLE enclosure door open at a 90 degree angle with a snap on cable for a convenient YOUR YOUR YOUR UR YOUR working surface in the field. LOGO L O L O L O LOGO Includes velcro strap for securing your laptop. Pg. 1 /2 ACEBOX DIMENSIONS 2.31 5 ORDERING INFORMATION 1.63 .88 1 T 13.00 12.59 P/N# SS000689 SRD System Record Documents Box - Red P/N# SS000690 SRD System Record Documents Box - Red with your custom screened logo P/N# SSU01689 SRD System Record Documents Box - Black P/N# SSU01690 SRD System Record Documents Box - Black with your custom screened logo P/N# SS000616 DCD Computer Desk Kit SY27 N FIEWaD www.lsae.com I toll free 1.800.486.1723 1 fax 508.485.4740 © Copyright 2018 Space Age Electronics, Inc. I This document subject to change without notice I LT10641 1 Rev. E 13.16 *o. Nam SOaEo (�' NFPA ADA Pg. 2/2 Fire Alarm System Battery Calculation Form PERFORMANCE Revision 042303nns SYSTEMS INTEGRATION 12/20/2024 System voltage (Vdc): 24 Supervisory Hours: 24 Alarm Minutes: 5 % Extra Battery Capacity: 25% AH required - Supervisory: 10.25 AH required -Alarm: 0.45 Total AH required (with %): 13.38 Battery AH provided: 18.00 Project name: Project number: Panel type: Panel Location: Power Supply ID: Comment: Swickward Toyata 35117326 EST 101000GD 2500ma was max loading for the orginal build. This value will be used for calculation purposes. Actual readings to be taken during testing. EST FIRE ALARM PANEL Line Identification Quantity Supervisory mA Alarm mA Total Sup. I/line Total Ala. I/line 1 101000RD 1 172 267 172.00 267.00 2 SA-DACT 1 41 1 41.00 1.00 3 SIGA-0SD 6 0.032 0.0045 0.192 0.027 4 SIGA-278 1 25 4 25.000 4.00 5 SIGA-CT1 6 25 4 150.00 24.00 6 SIGA-CR 3 1 4 3.00 12.00 7 RLCD-CR 1 36 146 36.00 146.00 8 NAC1 1 2500 0.00 2500.00 9 NAC2 1 2500 0.00 2500.00 10 0.00 0.00 11 0.00 0.00 12 0.00 0.00 13 0.00 0.00 14 0.00 0.00 15 0.00 0.00 16 0.00 0.00 17 0.00 0.00 18 0.00 0.00 19 0.00 0.00 20 1 1 1 1 1 0.00 1 0.00 Formula: (((Supervisory mA"Supervisory Hours)+(Alarm mA"Alarm Minutes))"Extra Capacity)= Total AH required Total Supervisory mA:1 427.19 Total Alarm mA: 1 5454.03 35117326 - Swickward Toyota Submittal T D Printed: 4:54 PM 12/20/2024