Loading...
APPROVED BLD RESUB1 BLD2024-1539+PLANS+12.17.2024_10.50.31_AM+4673971ALL WORK SUBJECT TO FIELD INSPECTION FOR CODE COMPLIANCE 24122 76th Ave W Edmonds Residence S240927-3XR PROJECT INFORMATION Special inspection required, see S-1. Provide all SI reports to city inspector prior to completion of project. CLIENT JOHNSON TODD D/CHRISTA M 24122 76TH AVE W EDMONDS, WA 98026 PROJECT ADDRESS 24122 76TH AVE W EDMONDS, WA 98026 STRUCTURAL ENGINEER L120 ENGINEERING & DESIGN 13150 91 ST PL N E KIRKLAND, WA 98034-5901 PHONE: (425) 636-3313 CONTACT: MANS THURFJELL, PE City Of Edmonds Building Department Work FOUNDATION STABILIZATION Address 24122 76TH AVE W ------------------------------------------------ Owner JOHNSON ----------------------------- Approved Date 12/27/2024 Building Official Erg Permit Number BLD2024-1539 CODES ENGINEERED PER: 2021 (IRC) INTERNATIONAL RESIDENTAL CODE 2021 (IBC) INTERNATIONAL BUILDING CODE SHEET INDEX COVER SHEET .... S-0 STRUCTURAL GENERAL NOTES .... S-1 SITE & FOUNDATION PLAN .... S-2 FOUNDATION DETAILS .... SD-1.1 � • � . T .H URA . • ��z- ,�-.., urn �� t 'O � • '•..ttt W Q z zo W r_Z� zw w V z W z z z 0Ow J REVISIONS 0 DESCRIPTION DATE BY _ RESUB Dec 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT PROJECT NAME 24122 76TH AVE W EDMONDS WA 98026 PROJECT NU 6ER S240927-3XR DRAWN L, JT CHECKED BY - M RT SHEET DATE 12/16/2024 SU z o O i DC (n V W > w 0 O w ULU GENERAL STRUCTURAL NOTES DESIGN CRITERIA HELICAL PILES CODE: 2021 IRC/IBC & AMENDMENTS AS ADOPTED BY THE REVIEWING AGENCY/COUNTY. 1. ROOF ........................................25 PSF SNOW (GROUND) FLOORS 2. RESIDENTIAL .....................40 PSF BALCONY/DECK................60 PSF 3. 4. GENERAL CONDITIONS 1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE STRUCTURAL ENGINEER OF ANY DISCREPANCIES HE MAY FIND BEFORE PROCEEDING WITH THE WORK. 5. 2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS BEFORE STARTING WORK. THE ARCHITECT/ENGINEER SHALL IMMEDIATELY BE NOTIFIED IN WRITING OF ANY DISCREPANCIES. 6. 3. ALL OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS SHALL 7. BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE STRUCTURAL ENGINEER BEFORE 8. PROCEEDING WITH ANY WORK SO INVOLVED. 4. IN CASE OF CONFLICT, NOTES AND DETAILS OF THESE STRUCTURAL DRAWINGS SHALL TAKE 9. PRECEDENCE OVER THE "GENERAL NOTES" AND/OR "STANDARD DETAILS". 5. IF A SPECIFIC DETAIL IS NOT SHOWN FOR ANY PART OF THE WORK, THE CONSTRUCTION SHALL BE THE SAME AS FOR SIMILAR WORK. 10 6. WORKING DIMENSIONS SHALL NOT BE SCALED FROM PLANS, SECTIONS, OR DETAILS ON THESE DRAWINGS. 7. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND THE STRUCTURAL ENGINEER OF ANY CONDITION WHICH IN HIS OPINION MIGHT ENDANGER THE STABILITY OF THE STRUCTURE OR CAUSE 11 DISTRESS TO THE STRUCTURE. 8. THE CONTRACTOR SHALL SUPERVISE AND DIRECT HIS WORK AND HE SHALL BE SOLELY RESPONSIBLE 12 FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES. PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. 13 9. ALL WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST EDITION OF THE INTERNATIONAL BUILDING CODE, AND ALL OTHER REGULATING AGENCIES EXERCISING AUTHORITY OVER 14 ANY PORTION OF THE WORK. 10. SPECIFIC NOTES AND DETAILS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS. 15 WHERE THE NOTES, DRAWINGS, AND/OR SPECIFICATIONS DIFFER, THE MORE STRINGENT REQUIREMENT SHALL APPLY. 11. REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION NOT COVERED BY THESE GENERAL NOTES OR THE STRUCTURAL DRAWINGS. 12. NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. 13. DISCREPANCIES FOUND BETWEEN STRUCTURAL DRAWINGS AND OTHER DOCUMENTS ARE TO BE NOTED IN WRITING TO THE ENGINEER PRIOR TO CONSTRUCTION. 14. ALL CONSTRUCTION SHALL BE DONE WITH MATERIALS, METHODS, AND WORKMANSHIP ACCEPTED AS GOOD PRACTICE BY THE CONSTRUCTION INDUSTRY IN CONFORMANCE TO THE PROVISIONS OF THE "INTERNATIONAL BUILDING CODE" (IBC), AND STANDARDS REFERENCED THEREIN. 15. STRUCTURAL STABILITY OF ALL NEW AND EXISTING STRUCTURES DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THIS INCLUDES EXCAVATIONS, COLUMNS, EQUIPMENT LOADS, MATERIAL LOADS, AND OTHERS. OBSERVATIONS BY THE ENGINEER -OF -RECORD DO NOT INCLUDE INSPECTIONS OF TEMPORARY LOADING AND STABILITY DURING CONSTRUCTION. 16. MINIMUM ASSUMED SOIL BEARING CAPACITY ............... 1,500 PSF 16 CONCRETE ANCHORS 1. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG TIE, HILTI, OR EQUIVALENT. SPECIAL INSPECTIONS REQUIRED. STRUCTURAL AND MISC. STEEL 1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES". 2. MATERIALS: BOLTS - ASTM A307, UNLESS OTHERWISE NOTED WF BEAMS - ASTM A572-50 (Fy = 50,000 PSI) HSS ROUND COLUMNS - ASTM A500 Gr. B (Fy = 42,000 PSI) HSS RECTANGULAR COLUMNS - ASTM A500 Gr. B (Fy = 46,000 PSI) ALL OTHER STEEL - ASTM A36 (Fy = 36,000 PSI) HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2021 INTERNATIONAL BUILDING CODE (IBC). HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY PRECISION PIER, INC., AND SHALL BE IN ACCORDANCE WITH ESR-5049. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH ESR-5049. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF +/- 1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-5049. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE AS PART OF THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE INSTALLATION OF EACH PILE AT SPECIFIC DEPTHS. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE FULLY ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE TORQUE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O21 AND 2018 IBC SECTION 1705.9 MUST BE PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION BRACKETS. ITEMS TO BE RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST INCLUDE THE FOLLOWING: A. PRODUCT MANUFACTURER B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS, EXTENSIONS, BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS SPECIFIED IN THIS REPORT AND THE CONSTRUCTION DOCUMENTS D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT USED, AND THE PRECISION PIER FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS E. ANTICIPATED AND ACTUAL PILING DEPTH F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION G. INCLINATION AND POSITION OF PILES, TOP OF PILE EXTENSION IN FULL CONTACT WITH BRACKET, TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS ARE INSTALLED BY AN APPROVED PRECISION PIER FOUNDATION SYSTEMS INSTALLER. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. HELICAL PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2021 INTERNATIONAL BUILDING CODE (IBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. PROOF TESTING SHALL BE IN ACCORDANCE WITH ASTM STANDARD D 1143-81. GEOTECHNICAL SPECIAL INSPECTOR SHALL BE CONTINUOUSLY PRESENT DURING PILE INSTALLATION AND LOAD TESTING. PROOF TESTING SHALL BE APPLIED TO EACH OF THE LOAD CONFIGURATIONS SPECIFIED IN THE PILE SPACING & LOAD REQUIREMENTS TABLE. MINIMUM ONE (1) PILE PER LOAD CONFIGURATION SHALL BE TESTED. CONCENTRIC DRIVEN PILES 2. STRUCTURAL STEEL WELDING 1. CONFORM TO THE AWS CODES D1.1 AND D1.3., AND USE ONLY CERTIFIED WELDERS. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY E70 ELECTRODES. 3. ALTERNATES: 1. ALTERNATE ASSEMBLIES AND MATERIALS WILL BE CONSIDERED FOR REVIEW. ENGINEER MAY REQUEST 4' PAYMENT FOR REVIEW; CONTRACTOR WILL BEAR BURDEN FOR ADDITIONAL PAYMENT AT NO ADDITIONAL 5' COST TO OWNER. JOBSITE SAFETY: 6. 1. THE ENGINEER AND/OR ARCHITECT HAVE NOT BEEN RETAINED OR COMPENSATED TO PROVIDE DESIGN AND/OR CONSTRUCTION REVIEW SERVICES RELATED TO THE CONTRACTOR'S SAFETY PRECAUTIONS OR 7. TO MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES FOR THE CONTRACTOR TO PERFORM 8. HIS WORK. THE UNDERTAKING OF PERIODIC SITE VISITS BY THE ENGINEER AND/OR ARCHITECT SHALL 9. NOT BE CONSTRUED AS SUPERVISION OF ACTUAL CONSTRUCTION NOR MAKE HIM RESPONSIBLE FOR PROVIDING A SAFE PLACE FOR THE PERFORMANCE OF WORK BY THE CONTRACTOR, SUBCONTRACTORS, 10 SUPPLIERS OR THEIR EMPLOYEES, OR FOR ACCESS, VISITS, USE, WORK, TRAVEL, OR OCCUPANCY BY ANY PERSON. "CONCENTRIC" OR DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2021 INTERNATIONAL BUILDING CODE (IBC). IT IS RECOGNIZED THAT THE INTERNATIONAL BUILDING CODE (IBC) REQUIRES 8 INCH MINIMUM DIAMETER PIPE FOR PIPE PILE INSTALLATION. THE APPROPRIATE ANALYSIS/EVALUATION AND TESTING REQUIREMENTS ARE PROVIDED TO ALLOW FOR USE OF PILES LESS THAN 8 INCHES IN DIAMETER AS REQUIRED BY SECTION 104.5 OF THE IBC. DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED BY STABIL-LOC SYSTEMS, LLC, AND SHALL BE IN ACCORDANCE WITH ESR-4121. ALL MATERIAL PROPERTIES OF DRIVEN PILE COMPONENTS SHALL COMPLY WITH ESR-4121. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING POLYMER (EAA) COATINGS (AC228). ALL PILE COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER AC358 SECTION 3.9. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED. DRIVEN PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE OF INCLINATION OF 1 DEGREE FROM VERTICAL PER SECTION 5.7 OF ESR-4121. DRIVEN PILES SHALL BE INSTALLED TO THE MINIMUM FORCE REQUIRED TO PROVIDE THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION FORCE SHALL NOT EXCEED THE ALLOWABLE CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE ASSEMBLY. ALL BRACKETS AND PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS THAN TWO (2). 12. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION. 13. SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1705.7 IS REQUIRED FOR INSTALLATION OF THE STABIL-LOC FOUNDATION PIERING SYSTEM. A GEOTECHNICAL SPECIAL INSPECTOR MUST VERIFY AND RECORD THE FOLLOWING: A. VERIFICATION OF MANUFACTURER PRODUCT MODEL NUMBERS B. TYPES, CONFIGURATIONS, AND IDENTIFICATIONS OF HYDRAULICALLY DRIVEN STEEL PIER SEGMENT AND ADJUSTABLE HEAD ASSEMBLY AS SPECIFIED IN ESR-4121 AND THE CONSTRUCTION DOCUMENTS. C. INSTALLATION PROCEDURES, ANTICIPATED AND ACTUAL PILING DEPTH D. TIP ELEVATIONS, THE INSTALLATION PRESSURE AND FINAL DEPTH OF THE DRIVEN FOUNDATION SYSTEM E. INCLINATION AND POSITION/LOCATION OF HYDRAULICALLY DRIVEN PIER SEGMENTS F. COMPLIANCE OF THE INSTALLATION WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THIS EVALUATION REPORT. 14. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED. DRIVEN PILE PROOF TESTING THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE (3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2021 INTERNATIONAL BUILDING CODE (IBC). THE MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD. SPECIAL INSPECTIONS SCHEDULE SPECIAL INSPECTIONS TABLES PER THE 2021 IBC. ALL ITEMS NON -APPLICABLE ITEMS HAVE BEEN MARKED WITH A "-". ITEMS REQUIRING SPECIAL INSPECTION HAVE BEEN MARKED WITH AN "X". TABLE 1705.3 REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION CONTINUOUS PERIODIC SPECIAL REFERENCED IBC TYPE SPECIAL INSPECTION INSPECTION 3 STANDARD REFERENCE 1 Inspect reinforcement including prestressing ACI 318 Ch- 20. 25 2, tendons and verify placement 25 3, 26 5 1-26 5 3 1 COS 4 2 Reinforcing bar welding a Verify weldability of reinforcing bars other than ASTM A 706: AWS D1-4 b- Inspect single -pass fillet welds_ maximum ACI 318= 26-5-4 c and 16 c Inspect all other welds - - 3 Inspect anchors cast in concrete - - ACI 318 17 8 2 - 4 Inspect anchors post -installed in hardened concrete members a Adhesive anchors installed in horizontally or upwardly inclined orientations to resist - - ACI 318 17 8 2 4 - sustained tension loads b Mechanical anchors and adhesive anchors not defined in -1 a 5 Verify use of required design mix - - ACI 318 Ch 19 1904 1 190.1 2 2643 2644 1908 2 1908 6 Prior to concrete placement fabricate specimens ASTM C 172 for strength tests perform slump and air - - ASTM C 31 190810 content tests. and determine the temperature of ACI 318 26A 5 26 12 the concrete 7 Inspect concrete and shotcrete placement for ACI 318. 26 5 1908 6, 1908 7- proper application techniques -4 1908 8 8 Verify maintenance of specified curing - - ACI 3118 26 4 7-26 4 9 19089 temperature and techniques 9 Inspect prestressed concrete for a Application of prestressing forces: and - - ACI 318: 26-9-2-1 - b Grouting of bonded prestressing tendons - - ACI 318 26-9-2-3 10 Inspect erection of precast concrete members - - ACI 318 Ch 26 8 - 11 Verify in -situ concrete strength- prior to stressing of tendons in post -tensioned concrete and - - ACI 318. 26-10-2 - prior to removal of shores and forms from beams and structural slabs 12 Inspect formwork for shape location and dimensions of the concrete member being - - ACI 318 26 10 1(b) - formed TABLE 1705.7 REQUIRED SPECIAL INSPECTIONS AND TESTS OF DRIVEN DEEP FOUNDATION ELEMENTS TYPE CONTINUOUS SPECIAL INSPECTION PERIODIC SPECIAL INSPECTION 1 Verify element materials sizes and lengths comply with the requirements - 2 Determine capacities of test elements and conduct additional load tests as required _ 3 Inspect driving operations and maintain complete and accurate records for each element _ 4 Verify placement locations and plumbness confirm type and size of hammer record number of blows per foot of penetration determine required penetrations to - achieve design capacity record tip and butt elevations and document any dama e to foundation element 5 For steel elements perform additional special inspections in accordance with Section ' 705 2- 6 For concrete elements and concrete -filled elements perform tests and additional special inspections in - - accordance with Section 1705 3 7 For specialty elements perform additional inspections as determined by the registered design professional in - responsible charge ABBREVIATIONS AB ANCHOR BOLT FTG FOOTING ABV ABOVE GA GAUGE AFF ABOVE FINISH FLOOR GALV GALVANIZED ALT ALTERNATE GLB GLULAM BEAM ALUM ALUMINUM GR GRADE APPROX APPROXIMATE GYP GYPSUM WALLBOARD AYC ALASKAN YELLOW CEDAR HDG HOT -DIPPED GALVANIZED BB BOX BEAM HDR HEADER BF BOTTOM FLUSH HF HEM FIR BLDG BUILDING HGT HEIGHT BLKG BLOCKING HT HEIGHT BM BEAM IN INCH BOT BOTTOM JT JOINT BP BOTTOM PLATE MAX MAXIMUM BRG BEARING MIN MINIMUM BTWN BETWEEN MISC MISCELLANEOUS BSMT BASEMENT NB NON -BEARING B/W BOTTOM OF WALL NO NUMBER CANT CANTILEVER OC ON CENTER CJ CONTROL JOINT PSF POUNDS PER SQUARE FOOT CLG. CEILING PSI POUNDS PER SQUARE INCH CLJ CEILING JOIST PT PRESSURE TREATED CLR CLEAR CMU CONCRETE MASONRY UNIT RAF RAFTER COL COLUMN REF REFERENCE CONIC CONCRETE REINF REINFORCEMENT CONN CONNECTION REQD REQUIRED CONST CONSTRUCTION SF SQUARE FOOT CONT CONTINUOUS SIM SIMILAR CTR CENTER SPF SPRUCE PINE FIR DET DETAIL STD STANDARD DF DOUGLAS FIR (SOUTH) SYP SOUTHERN YELLOW PINE DFL DOUGLAS FIR LARCH T/ TOP OF DIM DIMENSION T/C TOP OF CONCRETE DJ DOUBLE JOIST T/P TOP OF PLATE DIA DIAMETER T/S TOP OF STEEL DN DOWN T/W TOP OF WALL DS DOWN SPOUT TF TOP FLUSH EA EACH TJ TRIPLE JOIST EF EACH FACE T/BM TOP OF BEAM EJ EXPANSION JOINT ELEV ELEVATION T/SLABTOP OF SLAB EN EDGE NAILING (PANEL) TP TOP PLATE EQ EQUAL TYP TYPICAL ES EACH SIDE LINO UNLESS NOTED OTHERWISE EW EACH WAY UPA UNDER POST ABOVE FB FLUSH BEAM UWA UNDER WALL ABOVE FIN FINISH VERT VERTICAL FL FLOOR VIF VERIFY IN FIELD FLSHG FLASHING W/ WITH FIND FOUNDATION WC WESTERN CEDAR FP FIREPLACE WP WATERPROOF FT FOOT WWF WELDED WIRE FABRIC _a W � rn Z W �W°� r- _z w V W Z W z Z Z 00 w J i "- REVISIONS 0 DESCRIPTION DATE BY _ RESUB Dec 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-1539 PROJECT NAME 24122 76TH AVE W EDMONDS WA 98026 PRu,cCT NUMBER S240927-3XR DRAWN B JT CHECKED BY - M RT SHEET DATE 12/16/2024 SC U) LU z J Q OC D U D oC (10 o J � a W U z w w Ur w w FOUNDATION NOTES 1. VERIFY ALL DIMENSIONS ON SITE. 2. FOUNDATION DIMENSIONS ARE TO OUTSIDE FACE OF CONCRETE STEM WALL PER R&R LEVEL SURVEY. 3. REFER TO THE FOLLOWING DETAILS FOR ADDITIONAL INFORMATION: HELICAL PILE ................................ 1/SD-1.1 CONCENTRIC PILE ....................... 2/SD-1.1 POST W/ COMPOSITE PAD .......... 3/SD-1.1 4. REFER TO S1r17CTVPAr C tCOfAT(OITS-PAC�R.'Gf"DA'TED DECEMBER 16TH, 2024, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS. 5. LEVEL SURVEY PER R&R REPAIR PLAN DATED JANUARY 16TH, 2024. REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL REQUIREMENTS FOR REPAIR PLAN. 6. MINIMUM PILE DIAMETER SHALL BE 2-7/8". 7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH ± 0'-6" TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED DURING PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY. 8. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8" THICK MINIMUM WITH 2'-8" HEIGHT (MEASURED FROM B/FTG TO T/CONC) MINIMUM. 9. PARCEL AND RESIDENCE LOCATING DIMENSIONS (WITH ASTERISK, *) APPROXIMATED PER SNOHOMISH COUNTY iMAP. NOT TO BE USED FOR LEGAL PURPOSES. 10. SITE FEATURES AND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FOR CLARITY. 11. PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 6-0" (UNO PER GEOTECHNICAL REPORT). HELICAL PILE REFUSAL CRITERIA: TORQUING OF THE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY FACTOR OF NO LESS THAN TWO. ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE. SITE PLAN LEGEND EXISTING RESIDENCE STRUCTURE EXISTING ADJACENT STRUCTURE AREA OF PROPOSED WORK PROPERTY LINE - - - - APPROXIMATE DIMENSION HELICAL PILE CONCENTRIC PILE ® HSS 4x4x3/8 TUBE STEEL ® 4x4 POST W/ ADJ. PAD PILE SPACING & LOAD REQUIREMENTS TABLE PILE # PILE TYPE MAX O.C. SPACING, ft MIN VERTICAL CAPACITY, kips PROOF TESTING LOAD, kips LOCATION BTWN PILES END OFFSET ALLOWABLE LOADING 200% MIN VERTICAL CAPACITY (MIN ULTIMATE CAPACITY) 1-3 HELICAL 6'-011 PER PLAN 9.0 k/PILE 18.0 k/PILE EXTERIOR 4-6 8.0 k/PILE 16.0 k/PILE EXTERIOR 1 CONCENTRIC 6'-0" 18.0 k/PILE 36.0 k/PILE INTERIOR 2-3 PER PLAN 10.0 k/PILE 20.0 k/PILE CHIMNEY 6'-0" 8.0 k/PILE 16.0 k/PILE INTERIOR NOTES: a. MINIMUM AND MAXIMUM INSTALLATION TORQUE FOR HELICAL ASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER. THE MINIMUM INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING, INCLUDING A SAFETY FACTOR NO LESS THAN 2.0. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE ALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF THE PILE ASSEMBLY. MAXIMUM INSTALLATION TORQUE RATING OF 6,843FT*LBS FOR A 2-7/8 INCH DIAMETER HELICAL PILE WITH 0.217 INCH SHAFT WALL THICKNESS PER ESR-5049. b. HELICAL ASSEMBLIES AS MANUFACTURED BY PRECISION PIERS, INC., IN ACCORDANCE WITH ESR-5049. c. PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF THE ASSEMBLY. d. MAXIMUM ON -CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN. r---------------•—•�.�. ------------------------------------------------------------------------------------------------------------ PROPERTY LINE -------- ---------- 1 146'-0" , 1 1 1 ' 1 ' 1 1 1 • I 1 ' 1 ' ■ 1 ' , 1 1 1 ' 1 ' 1 1 1 I 1 1 1 I ■ ; (E) GARAGE ; DRIVEWAY ACCESS ■ 1 ■ I 1 ' ■ 1 1 1 ■ I 1 ' 1 ' 1 ' 1 • I 1 1 ■ ■ 1 I 1 1 ' 1 1 1 ' ----------------------------------------------------- ■ 26v-611 241_011 i o LI . I , ,6-0"- I ■ RESIDENCE 24122 76TH AVE W 7 8 6 ■ I EDMONDS, WA 98026 6'-0„ I� I 2 c�0 5 6 4 11 10 Co■M _ - 0 00■ o f 161-611 , N ol_ m PRIMARY. ACCESS I r ,z 1 I "-' V_v 6,_0„ _ , CD (E) CHIMNEY N 5 N 1 3 4 0 RECOMMEND ADDING ONE ADDITIONAL PILE TO I 01'114 ACHIEVE 6'-0" OC MAX 391_011 1 I 2 3 I ■ I PROPERTY LINE 146'-0" * NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS. OCATE Pill (THIN 1'-0 OM OPE '4 1*2 1 7/8 2 it 3a (3) PILES @ 6-0" AC MAX f 40 1 S�" 1 t�, T S v 11' RECOMMEND ADDING t° ONE ADDITIONAL PILE TO ACHIEVE 6'4" OC MAX 12- 55, 41 NG 4• 1/4 LOCATE F ILE UNDL CHLIMPW FTG AT CHIMNEY TRIP FT(9 CORNER. 80 —2X6 's'= Lb' on cente► -I T4 - i I .i R&R LEVEL SURVEY * = 3" Helical Pile Concentric Poor ■ 4x4 Post wa- composito m LOCATE PILE WITHIN 3'-0" FROM CORNER See Structural Calculation Package for Additional Requirements SITE PLAN W 0 5 z o �W-6 r— _z w V w z W W z Z 00w J i" REVISIONS 0 DESCRIPTION DATE BY _ RESUB Dec 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-1539 PROJECT NAME 24122 76TH AVE W EDMONDS WA 98026 PROJECT NUMBER S240927-3XR DRAWN L, JT CHECKED BY - M RT SHEET DATE 12/16/2024 SU I z 001 J N U) u 01 co w w (E) WOOD FRAMED' 6x1? DFx (E) WOOD FRAMED . FLOOR SYSTEM, —MINIMUM FLOOR SYSTEM, FIELD VERIFY FIELD VERIFY I � j I (E) CONIC STEM WALL (E) CONIC STEM WAIL TISTEM WALL = T/STEM WALL = � FIELD VERIFY FIELD VERIFY 8" MIN THICKNESS, I 8 MIN THICKNESS, 1 L T FIN GRADE - CONTRACTOR TO VERIFY LM _ T/FIN GRADE - SIMPS014 PCZ POSTWf_�f�llPOST PFR PLAN MIN CONTRACTOR TO VERIFY 4X4 CAP NNOTE 2JIIII. VARIES°�VARIES [NOTE 4) d _ c (E) FTG TO BE CUT FLUSH _ o o d 11=IIII=IIII=IIII= Inl=nn=lnl=nll I CRUSH BLOCKING TO MATCH �_ SIMPSON EPB POST �_ BASE (NOTE 21 OR EXCEED MIN BEARING C� O } U „- I I WITH FACE OF STEM WALL - � = Q d 11=IIII=IIII=IIII=1 �. AREA OF 04 POST STD NUT AND 3• DIAM Of ;,'11I WITH A 12 MAX WIDTH FOR z > IIII=IIII=IIII=IIII. ° l d 11=IIII=IIII=IIII=III ,'NOTE 31 (MIN) FLAT WASHER Z O INSTALLATION POCKET z O d IIII=IIII=IIII=IIII= ' 11=IIII=IIII=IIII=III EA SIDE OF PAD LI_ l_ o U ° IIII=IIII=IIII=IIII. 16 Or 20 DIAhI AG -CD �• -i. T/CONC FTG = d riiil==Illl==Illl==Illl=-Il TICONC FTG = COMPOSITE FOOTING PAD (NOTE 11 ' FIELD VERIFY -I��I = _ _ _ _ ° =IIII=IIII=IIII=IIII=IIII=11 .. ° ° .. I = _ = FIELD VERIFY IIII=IIII=III =IIII=IIII=IIII- "' d "' d "' d 11=IIII=IIII= WEDGE ANCHORS ToGRADE ° PER STABIL-LOC INTERIOR �' =""="n ''=IIII- II=IIII _ =IIII=IIII=IIII n=IIII=n►' REQUIREMENTS (E) CONTINUOUS CONC FOOTING PRECISION PIERS HELICAL - �II,IIIIII�I I - (E) CONTINUOUS - IIII = ' mi IIII-�"� HSS4x4x3,'8 PILE & REPAIR BRACKET CONIC FOOTING ASSEMBLY PER TES SPACER R&R FOUNDATION SPECIALIST NOTES. 1 CONTRACTOR TO VERIFY NOTED MINPAW EXISTING FOUNDATION T CONFORM T R- CD G O ES 5049 1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION -� L. STABIL-LOC CONCENTRIC PIER DIMENSIONS PRIOR TO INSTALLATION ENGINEER -OF -RECORD TO BE DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE ASSEMBLY PER R&R FOUNDATION NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET. SPECIALIST TO CONFORM TO ESR-4121 2 ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION 2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION T NOTES RESISTANT SYSTEM THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED HOLES CORROSION PREVENTION COATING SYSTEM BY OTHERS PRIME A40 HOLES. CORROSION PREVENTION COATING SYSTEM BY OTHERS. PRIME 1. COMPOSITE FOOTING PAD DER ESRQ147. PAINT PER MFR OR GALVANIZATION PER ASTM 1531A123 AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123. 2. BEAM & COLUMN FASTENER QUANTITY AND SIZE PER SIMPSON STRONG -TIE. 3 AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT 3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT J 3. CRUSH BLOCKING TO BE INSTALLED AFTER POST BASE ADJUSTMENT TO SHALL BE SEALED OR COATED TO PREVENT CORROSION. SHALL BE SEALED OR COATED TO PREVENT CORROSION. Q Ii�: 4 REFER TO GENERAL NOTES FOR GEOTECHNICAL PILE EMBEDMENT 4. REFER TO GENERAL NOTES FOR GEOTECHNICAL PILE EMBEDMENT 11 Iw ENSURE FULL BEARING AREA OF MIN POST SIZE AS REQUIRED PER ESR-2147. REQUIREMENTS. NOTE THAT THESE SHALL BE ACHIEVED PRIOR TO THE REQUIREMENTS. NOTE THAT THESE SHALL BE ACHIEVED PRIOR TO THE w 4, WOOD MEMBERS MUST BE EITHER SAWN OR ENGINEERED LUMBER APPLICATION OF THE REFUSAL CRITERIA APPLICATION OF THE REFUSAL CRITERIA. EL cn 5 REFER TO GENERAL NOTES FOR PILE FIELD TESTING REQUIREMENTS 5. REFER TO GENERAL NOTES FOR PILE FIELD TESTING REQUIREMENTS. RECOGNIZED IN AN ICC-ES EVALUATION REPORT. HELICAL PILE INSTALLATION DETAIL 2 DRIVEN PILE INSTALLATION DETAIL 3 4 5 6 _a W 0 zo � Lu z r— w V � z W z zo O0ww J REVISIONS Q DESCRIPTION DATE FBY _ RESUB Dec 17 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT BLD2024-1539 PROJECT NAME 24122 76TH AVE W EDMONDS WA 98026 PROJECT NUMBEh S240927-3XR brviv IV G JT CHECKED BY - M RT SHEET DATE 12/16/2024 SIC, J Q W 0 z O - o Q 0 0 U) z V ''-' O 0 w LL =