REVIEWED RESUB1 BLD2024-1539+CALCS+12.17.2024_10.50.31_AM+4673972RESUB
Dec 17 2024
CITY OF EDMONDS
DEVELOPMENT SERVICES
DEPARTMENT
BLD2024-1539
-LONGITUDE-
ONE TWENWO
ENGINEERING & DESIGN
Calculation Package for
Foundation StabifizationlLift
REVIEWED
BY
CITY OF EDMONDS
STRUCTURAL ENGINEER
L120 ENGINEERING & DESIGN
1315091"PLNE
KIRKLAND, WA 98034-5901
24122 76th Ave W
Edmonds, WA 98026
Project No: S240927-3XR
December 16th, 2024
Prepared for:
R&R Foundation Specialist
1611 East Marine View Drive
Everett, WA 98201
P: 425.760.5077
CONTACT: MANS THURFJELL, PE
EMAIL: MTHURFJELL@L120ENGINEERING.COM
PHONE: (425) 636-3313
1 of 26
FOUNDATION NOTES
1. VERIFY ALL DIMENSIONS ON SITE.
2. FOUNDATION DIMENSIONS ARE TO CUMIDE FACE OF CONCRETE STEM WALL PER RM LEVEL SURVEY.
3. REFER TO F WIN'"D F PD RI01 INFORMATION:
HELICAL P LE ................................ 11561.1
CONCENTRIC PILE ....................... Z561.1
POST WI COMPOSITE PPD.......... 315D-1.1
4. REFER TO ED DECEMBER 18TH,2024, FOR ADDITIONAL INFORMATION, SPECIFICATIONS, AND REQUIREMENTS.
5. LEVEL SURVEY PER R&R REPAIR RAN DATED JANUARY 16TH,2024. REFER TO STRUCTURAL CALCULATIONS PACKAGE FOR MODIFICATIONS AND ADDITIONAL
REQUIREMENTS FOR REPAIR PLAN.
6. MINIM UMPILEDIAMETERSHALLBE2-TIE",
7. IT IS ACCEPTABLE TO INSTALL PILES AT THE SPACING SHOWN WITH T 943• TOLERANCE TO ALLOW FOR UNEXPECTED OBSTRUCTIONS ENCOUNTERED DURING
PILE INSTALLATION PROVIDED THAT NO TWO ADJACENT SPANS EXCEED THE SPACING LIMITATION AS INDICATED ON LEVEL SURVEY.
8. FIELD VERIFY ALL EXISTING STEM WALLS AT AND BETWEEN PILE ATTACHMENT LOCATIONS ARE 8- THICK MINIMUM WITH 2'A" HEIGHT (MEASURED FROM BATG TO
VCONC)MINIMUM.
9. PARCEL AND RESIDENCE LOCATING DIMENSIONS (WITH ASTERISK,') APPROXIMATED PER SNOHOMISH COUNTY,MAP. NOT TO BE USED FOR LEGAL PURPOSES.
10. SITE FFATURESAND EXISTING STRUCTURES ON ADJACENT PARCELS NOT SHOWN FORCLARITY.
11. PILES SHALL BE INSTALLED TO A MINIMUM EMBEDMENT OF 5'1r' K NO PER GEOTECHNICAL REPORT).
HELICAL PILE REFUSAL CRITERM:
TORW ING OFTHE PILE SHALL CONTINUE UNTIL A HYDRAULIC PRESSURE IS ACHIEVED TO PROVIDE THE SPECIFIED MINIMUM VERTICAL CAPACITY WITH A SAFETY
FACTOR OF NO LESS THAN TWO. ADVANCEMENT SHALL BE HALTED IMMEDIATELY IF THE STRUCTURE BEGINS TO EXPERIENCE UPLIFT FLEXURE.
—.—.—.—.—.—.—.—.—.—.—.
.—.�.—.�.—.� PROPERTY LINE
I
I
I
------------------------------------------------------- .—.—
I
I
I
I
I
I
I
I
I
(E) GARAGE ORIVI
t-------------------------------------------------
I
i
iEDMONDS,
19
-
26' 6"
RESIDENCE
24122 ]6TH AVE W
WA 98026
9 116'-6"
Ir
PARCEL NO.
Im
00491100000901
LEGAL DESCRIPTION
LAKE MC ALEER 5 ACRE TRACTS BLK
NO D-01 - BEG MFT N OF SE COR
'
LOT 9 TH W 175FT THIN SOFT TH E
175FT TH S SOFT TO POB LESS E 30FT
-
OWNER NAME & ADDRESS
JOHNSON TODD DICHRISTA M
]6TH AVE W
i
I
I
I
24122
DMONDS, WA 90026
■ EXISTING RESIDENCE STRUCTURE
EXISTING ADJACENT STRUCTURE
AREA OF PROPOSED WORK
" PROPERTY LINE
---- APPROXIMATE DIMENSION
HELICAL PILE
CONCENTRIC PILE
ASS 4x4x3/8 TUBE STEEL
® 4x4 POST W/ ADJ. PAD
PILE SPACING & LOAD REQUIREMENTS TABLE
MAX O.C. SPACING, fI
MIN VERTICAL CAPACITY, kips
PROOF TESTING LOAD, kips
PILE#
PILETYPE
BTWN PILES
END OFFSET
ALLOWABLE LOADING
200%MIN VERTICAL
CAPACITY
(MIN ULTIMATE CAPACITY)
LOCATION
1-3
4-6
HELICAL
6'-0"
PER PLAN
9.0 k/PILE
18.0 k/PILE
EXTERIOR
8.0 k/PILE
16.0 k/PILE
EXTERIOR
1
2-3
4
CONCENTRIC
1
6'-0'
PER PLAN
1 6'-0"
18.0 k/PILE
36.0 k/PILE
INTERIOR
10.0 k/PILE
20.0 k/PILE
CHIMNEY
8.0 k/PILE
16.0k/PILE
INTERIOR
NOTES'
a. MINIMUMAND MAXIMUM INSTALLATION TORQUE FOR HELICALASSEMBLIES SHALL BE SPECIFIED BY THE PILE MANUFACTURER. THE MINIMUM
INSTALLATION TORQUE SHALL BE HIGH ENOUGH TO ACHIEVE THE REQUIRED BEARING CAPACITY LOADING, INCLUDING ASAFETY FACTOR NO LEW
THAN 2.0. THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THEALLOWABLE TORSIONAL CAPACITY OF THE PILE SHAFTS OR ANY PART OF
THE PILE ASSEMBLY. MAXIMUM INSTALLATION TORQUE RATING OF 6,8OMLBS FORA2-7G INCH DIAMETER HELICAL PILE WITH 0.217INCH SHAFT
WALL THICKNESS PER EW-5M9.
b. HELICAL ASSEMBLIES AS MANUFACTURED BY PRECISION PIERS, INC., IN ACCORDANCE WITH ESR,%49.
c PILE OR ANCHOR LOADS NOT TO EXCEED MAXIMUM CAPACITY AS DETERMINED BY THE MANUFACTURER FOR ANY PART OF THE ASSEMBLY.
J. MAXIMUM ON -CENTER SPACING LISTED FOR TYPICAL PILE INSTALLATION UNLESS NOTED OTHERWISE ON PLAN.
.—.—.—.—.—.—.—.—.—.—.—.—.—.—.—•—.---------------.—.—.------'
I
I
—•---------------------------------"—. PR_oPERTYLINE—'-----.—'----
•—•—.—•—.—•—•—.—.—.—
146 0
.—
NOTE: THE PROJECT WILL NOT RESULT IN CHANGING OF SITE TOPOGRAPHY OR EXISTING DEVELOPED AREAS.
173'
fA
AaMcn
a
Q • 7" Hskcal PIN
�CATE PI
)THIN 1'-
I SA'
A
Q = Cvk Pw
as;er
OM OPEI
NG 1'
a
• • 4x POM MAeI
114
1 1 716 2
1114
/ R
1
1 IB
3
LOCATE UNDER
G.
(31 LES ®
CNIEI{♦NE' TO Ai
-CNM4EY TRW FTa le
1 8'0' C MA%
CORNER
EMU 4
B
81
3
is
T
-
11'
S
O
LOCATE PILE
WITHIN 3'0'
RECOMMEND ADDING
W
FROM CORNER
ONE ADDITIONAL PILE TO
ACHIEVE V-D" OC MAX
17
R&R LEVEL
SURVEY
See Structural
Calculation
Packs a for Additional
Requirements
SITE PLAN
W
JyW
d
Zn
Q06
J
sFEVIISTONS3
PROECT NAME
24122 76TH AVE W
EDMONDS
WA 98026
P ER
S240927-3XR
CTaW', JT
CHECNrI MRT
12/16/2024
5 N
a V)
Lu
o fN
N
O
M
N
PROJECT
LONGITUDE SUBJECT
ONE TWENTYO
ENGINEERING & DESIGN
BY JT
. .
PROJECT NO. SHEET NO.
,0• •
24122 76th Ave W Edmonds WA 98026
Foundation Stabilization/Jacking
DATE
12/16/2024
Scope/Objective:
To determine the required pile spacing and geometry to stabilize and lift (where required) the existing structural foundation. These
findings have been based upon the calculated strength of the existing foundation system and the current vertical loading from the
existing structure above (based on as -built assessments).
The R&R Foundation Specialists' (R&R) proposed pile layout can be found in the following pages with structural recommendations
based upon the findings of L120 Engineering & Design.
Note that cosmetic damages to rigid wall coverings/members and siding are expected during a foundation lift. Such cosmetic
damages/cracks are to be repaired by others following the completion of the foundation stabilization and lifting and are not included in
the structural scope presented here.
It should be further noted that L120's scope is limited to the perimeter support systems/continuous footings. The interior crawl -space
support system for the first floor shall be installed per R&R. This could include the use of some or all of the following: longer support
posts, adjustable post -base hardware, and/or the addition of taller wood support members. Settlement in these interior support areas
shall be monitored and further adjustments shall be made if necessary.
Structural Summary
- The foundation of the residence consists of continuous cast -in -place concrete stem wall and concrete strip footings. Below the footings,
piles are to be spaced at a distance no larger than 6-0" o.c. w/ the installation of supplemental of HSS 4x4x3/8 tube steel as indicated
on the attached Level Survey.
End piles shall not exceed the maximum corner offset as specified on the attached Level Survey
- A maximum allowable loading of 1,850 plf was utilized in this analysis. This was determined through inspection of building geometry
and conservative span/tributary loading assumptions based on standard construction practices
- The following load values represent the maximum expected pile loads for the indicated spacing. R&R to provide pile and equipment
assemblies with capacities equal to or greater than the indicated load values.
Allowable Load Capacity Requirement:
Helical #1-3 & Concentric #1 @ 6-0" o.c. ................. 9.0 kip minimum vertical capacity (allowable load)
Helical #4-6 & Concentric #4 @ 6'-0" o.c. ................. 8.0 kip minimum vertical capacity (allowable load)
Concentric #2-3 @ Chimney ..................................... 18.0 kip minimum vertical capacity (allowable load)
Note: Refer to the attached General Notes for additional requirements.
- As determined by R&R, the site appears to have no lateral (horizontal) displacements or concerns. As such, the analysis and
recommendations presented in this report have been strictly limited to vertical stabilization/jacking. If lateral movement is observed or
expected additional structural analysis will be required.
- Structural recommendations contained in this package are based on site photographs dated January 16th, 2024, provided by R&R. To
the knowledge of L120, a geotechnical investigation was not performed on this site. Consequently, all structural recommendations
assume adequate soil conditions to obtain the required pile capacities.
Please inform L120 of site -specific conditions that were unconsidered by, may conflict with, or otherwise compromise the
recommendations contained within this package, including, but not limited to, water drainage, slope stability, existing structural damage,
or existing subsurface obstructions. In this instance, the structural assumptions, recommendations, and scope for this project will need
to be revisited to consider and address the new findings
Refer to the following pages for pile and connection specifications.
L120 ENGINEERING & DESIGN
CIno r4.
GENERAL NOTES
HELICAL PILES
1. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE WITH THE 2021
INTERNATIONAL BUILDING CODE (IBC).
2. HELICAL PILES SHALL BE DESIGNED AND MANUFACTURED BY PRECISION PIERS, INC., AND
SHALL BE IN ACCORDANCE WITH ESR-5049.
3. ALL MATERIAL PROPERTIES OF HELICAL PILE COMPONENTS SHALL BE IN ACCORDANCE WITH
ESR-5049.
4. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES
ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING
POLYMER (EAA) COATINGS (AC228).
5. ALL HELICAL FOUNDATION COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE
REINFORCING STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING
COMPONENTS PER AC358 SECTION 3.9.
6. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS.
7. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED.
8. HELICAL PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE
OF INCLINATION OF +/- 1 DEGREE FROM VERTICAL PER SECTION 4.2.1 OF ESR-5049.
9. MONITOR AND RECORD DEPTH OF PILE PENETRATION. PROVIDE TORQUE MONITORING DEVICE
AS PART OF THE INSTALLING UNIT. MONITOR AND RECORD TORQUE APPLIED DURING THE
INSTALLATION OF EACH PILE AT SPECIFIC DEPTHS.
10. HELICAL PILES SHALL BE INSTALLED TO THE MINIMUM TORQUE VALUE REQUIRED TO PROVIDE
THE MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF
SAFETY NO LESS THAN TWO (2). THE MAXIMUM INSTALLATION TORQUE SHALL NOT EXCEED THE
ALLOWABLE TORSIONAL CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE PILE ASSEMBLY.
11. ALL BRACKETS AND HELICAL PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY
TO ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO
LESS THAN TWO (2).
12. REPAIR BRACKETS MUST BE CONCENTRICALLY LOADED AND THE BRACKET PLATE MUST BE
FULLY ENGAGED WITH BOTTOM OF CONCRETE FOUNDATION.
13. ALL HELICAL PILE ASSEMBLY COMPONENTS MUST HAVE ADEQUATE STRENGTH TO DEVELOP THE
TORQUE REQUIRED FOR INSTALLATION AND ALL INDUCED STRESSES.
14. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED
WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION.
15. CONTINUOUS SPECIAL INSPECTION IN ACCORDANCE WITH 2O21 IBC SECTION 1705.9
MUST BE PROVIDED FOR THE INSTALLATION OF THE HELICAL PILES AND FOUNDATION
BRACKETS. ITEMS TO BE RECORDED AND CONFIRMED BY THE SPECIAL INSPECTOR MUST
INCLUDE THE FOLLOWING:
A. PRODUCT MANUFACTURER
B. MANUFACTURER'S CERTIFICATION OF THE INSTALLERS
C. PRODUCT TYPE AND CONFIGURATIONS FOR HELICAL PILE LEAD SHAFT SECTIONS,
EXTENSIONS, BRACKETS, BOLTS, THREADED RODS, NUTS, WASHERS, AND TORQUES AS
SPECIFIED IN THIS REPORT AND THE CONSTRUCTION DOCUMENTS
D. INSTALLATION PROCEDURES FOR THE HELICAL PILE SHAFT, INSTALLATION EQUIPMENT
USED, AND THE PRECISION PIERS FOUNDATION SYSTEMS INSTALLATION INSTRUCTIONS
E. ANTICIPATED AND ACTUAL PILING DEPTH
F. REQUIRED TARGET INSTALLATION TORQUE OF PILES AND MINIMUM DEPTH OF INSTALLATION
G. INCLINATION AND POSITION OF PILES, TOP OF PILE EXTENSION IN FULL CONTACT WITH
BRACKET, TIGHTNESS OF ALL BOLTS AND EVIDENCE THAT THE PILE FOUNDATION SYSTEMS
ARE INSTALLED BY AN APPROVED PRECISION PIERS FOUNDATION SYSTEMS INSTALLER.
16. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO
MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON
REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED.
HELICAL PILE PROOF TESTING
THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE
(3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE
PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2021 SEATTLE BUILDING CODE (SBC). THE
MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD.
-mr4l.
GENERAL NOTES
CONCENTRIC/DRIVEN PILES
1. "CONCENTRIC" OR DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED IN ACCORDANCE
WITH THE 2021 INTERNATIONAL BUILDING CODE (IBC).
2. IT IS RECOGNIZED THAT THE SEATTLE BUILDING CODE (SBC) REQUIRES 8 INCH MINIMUM
DIAMETER PIPE FOR PIPE PILE INSTALLATION. THE APPROPRIATE ANALYSIS/EVALUATION AND
TESTING REQUIREMENTS IN ACCORDANCE WITH SEATTLE DEPARTMENT OF CONSTRUCTION &
INSPECTIONS (SDCI) DIRECTOR'S RULE 10-2009 ARE PROVIDED TO ALLOW FOR USE OF PILES
LESS THAN 8 INCHES IN DIAMETER AS REQUIRED BY SECTION 104.5 OF THE SBC.
3. DRIVEN PILES SHALL BE DESIGNED AND MANUFACTURED BY STABIL-LOC SYSTEMS, LLC, AND
SHALL BE IN ACCORDANCE WITH ESR-4121.
4. ALL MATERIAL PROPERTIES OF DRIVEN PILE COMPONENTS SHALL COMPLY WITH ESR-4121.
5. CORROSION PROTECTION OF ALL PILE COMPONENTS SHALL COMPLY WITH THE ICC-ES
ACCEPTANCE CRITERIA FOR CORROSION PROTECTION OF STEEL FOUNDATION SYSTEMS USING
POLYMER (EAA) COATINGS (AC228).
6. ALL PILE COMPONENTS SHALL BE GALVANICALLY ISOLATED FROM CONCRETE REINFORCING
STEEL, BUILDING STRUCTURAL STEEL, OR ANY OTHER METAL BUILDING COMPONENTS PER
AC358 SECTION 3.9.
7. THE SHAFT SHALL BE DESIGNED AND FABRICATED TO SUPPORT THE SPECIFIED DESIGN LOADS.
8. ONLY MANUFACTURER -APPROVED CONNECTORS, ADAPTORS, AND ACCESSORIES MAY BE USED.
9. DRIVEN PILES SHALL BE INSTALLED VERTICALLY INTO THE GROUND WITH AN ALLOWABLE ANGLE
OF INCLINATION OF 1 DEGREE FROM VERTICAL PER SECTION 5.7 OF ESR-4121.
10. DRIVEN PILES SHALL BE INSTALLED TO THE MINIMUM FORCE REQUIRED TO PROVIDE THE
MINIMUM REQUIRED LOAD CAPACITIES INDICATED ON PLAN INCLUDING A FACTOR OF SAFETY NO
LESS THAN TWO (2). THE MAXIMUM INSTALLATION FORCE SHALL NOT EXCEED THE ALLOWABLE
CAPACITY OF ANY INDIVIDUAL COMPONENT OF THE ASSEMBLY.
11. ALL BRACKETS AND PILE ASSEMBLY COMPONENTS SHALL HAVE ADEQUATE CAPACITY TO
ACHIEVE THE MINIMUM REQUIRED BEARING CAPACITY INCLUDING A FACTOR OF SAFETY NO LESS
THAN TWO (2).
12. THE PILE QUANTITY, LAYOUT, AND SPACING INDICATED ON PLAN SHALL NOT BE CHANGED
WITHOUT WRITTEN APPROVAL FROM THE ENGINEER -OF -RECORD PRIOR TO INSTALLATION.
13. SPECIAL INSPECTION IN ACCORDANCE WITH IBC SECTION 1705.7 IS REQUIRED FOR INSTALLATION
OF THE STABILLOC FOUNDATION PIERING SYSTEM. A GEOTECHNICAL SPECIAL INSPECTOR MUST
VERIFY AND RECORD THE FOLLOWING:
A. VERIFICATION OF MANUFACTURER PRODUCT MODEL NUMBERS
B. TYPES, CONFIGURATIONS, AND IDENTIFICATIONS OF HYDRAULICALLY DRIVEN STEEL PIER
SEGMENT AND ADJUSTABLE HEAD ASSEMBLY AS SPECIFIED IN ESR-4121 AND THE
CONSTRUCTION DOCUMENTS.
C. INSTALLATION PROCEDURES, ANTICIPATED AND ACTUAL PILING DEPTH
D. TIP ELEVATIONS, THE INSTALLATION PRESSURE AND FINAL DEPTH OF THE DRIVEN
FOUNDATION SYSTEM
E. INCLINATION AND POSITION/LOCATION OF HYDRAULICALLY DRIVEN PIER SEGMENTS
H. COMPLIANCE OF THE INSTALLATION WITH THE APPROVED CONSTRUCTION DOCUMENTS
AND THIS EVALUATION REPORT.
14. PILES IMPROPERLY INSTALLED BECAUSE OF MISLOCATION, MISALIGNMENT, OR FAILURE TO
MEET OTHER SPECIFIED DESIGN/INSTALLATION CRITERIA ARE NOT ACCEPTABLE. ABANDON
REJECTED PILES AND INSTALL ADDITIONAL PILES AS REQUIRED.
DRIVEN PILE PROOF TESTING
THE CAPACITY OF THE INSTALLED PILES SHALL BE VERIFIED BY FIELD TESTING OF A MINIMUM THREE
(3) PERCENT OF PILES UP TO FIVE (5) PILES MAXIMUM (ONE (1) MINIMUM) IN ACCORDANCE WITH THE
PROCEDURE OUTLINED IN ASTM D1143 AND/OR THE 2021 SEATTLE BUILDING CODE (SBC). THE
MAXIMUM TEST LOAD SHALL BE TWO -HUNDRED (200) PERCENT OF THE SPECIFIED DESIGN LOAD.
A no r4l.
GENERAL NOTES
STRUCTURAL STEEL
1. REFERENCE STANDARDS: DESIGN, FABRICATION AND ERECTION ARE TO BE IN ACCORDANCE
WITH THE LATEST EDITION OF THE AISC "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS
AND BRIDGES".
2. MATERIALS:
BOLTS - ASTM A307, UNLESS OTHERWISE NOTED
ALL OTHER STEEL - ASTM A36 (Fy = 36,000 PSI)
3. ALL WELDING SHALL BE PERFORMED BY CERTIFIED WELDERS AND CONFORM TO AWS CODES
D1.1 AND D1.3. WELDS NOT SPECIFIED ARE TO BE 1/4" CONTINUOUS FILLET MINIMUM. USE DRY
E70 ELECTRODES. WHERE ON -SITE WELDING IS REQUIRED, SPECIAL INSPECTION IN
ACCORDANCE WITH 2O21 IBC SECTION 1705.2 IS ALSO REQUIRED.
CONCRETE
1. REFERENCE STANDARDS: ACI 301, ACI 318, IBC.
2. MINIMUM CONCRETE STRENGTH (28 DAYS):
FOOTINGS AND STEM WALLS..................................................3,000 PSI - 5 SACK MIX
BASEMENT FOUNDATION RETAINING WALLS .......................3,000 PSI - 5 SACK MIX
SLAB-ON-GRADE........................................................................2,500 PSI - 5 SACK MIX
SLAB -ON -GRADE... EXPOSED WEATHERING SURFACES ...... 3,000 PSI
AIR -ENTRAINMENT 2.5% TO 5.5% FOR EXPOSED CONCRETE
3. MIXING: COMPLY WITH ACI 301. DO NOT EXCEED THE AMOUNT OF WATER SPECIFIED IN THE
APPROVED MIX. PROPORTIONS OF AGGREGATE TO CEMENT SHALL BE SUCH AS TO PRODUCE A
DENSE, WORKABLE MIX WHICH CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE
SURFACE WATER.
4. PLACING: COMPLY WITH ACI 301. PROVIDE A 3/4 INCH CHAMFER AT ALL EXPOSED CONCRETE
EDGES, UNLESS INDICATED OTHERWISE ON ARCHITECTURAL DRAWINGS.
5. SLUMP: 4 INCHES PLUS OR MINUS 1 INCH. DO NOT ADD WATER TO MIX TO INCREASE SLUMP.
GREATER SLUMP, ACCELERATED SET, OR HIGH EARLY STRENGTH MAY BE ACHIEVED BY USING
APPROVED ADMIXTURES.
6. CURING: COMPLY WITH ACI 301. KEEP CONCRETE MOIST FOR SEVEN DAYS MINIMUM.
7. JOINTING: PROVIDE ADEQUATE JOINTING TO MINIMIZE EFFECTS OF VOLUME CHANGE. JOINTS
SHOWN MAY BE ADJUSTED AT CONTRACTOR'S OPTION WITH PRIOR APPROVAL FROM ENGINEER.
8. WEATHER EXTREMES: COMPLY WITH ACI 305R FOR HOT WEATHER. COMPLY WITH ACI-306R FOR
COLD WEATHER.
9. WATER/CEMENT RATIO SHALL NOT EXCEED 0.50 (BY WEIGHT), TYPICAL.
10. ALL SPECIFIED CONCRETE ANCHORS SHALL BE SIMPSON STRONG -TIE, HILTI, OR EQUIVALENT.
SPECIAL INSPECTIONS REQUIRED. ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH
MINIMUM EMBEDMENT, SPACING, EDGE DISTANCE, AND REQUIREMENTS PER MANUFACTURER.
LONGITUDE
ONE TWENTYO
ENGINEERING & DESIGN
. .
PROJECT NO. SHEET NO.
. 0•
PROJECT 24122 76th Ave W Edmonds WA 98026
SUBJECT Foundation Stabilization/Jackin
BY JT
DATE
12/16/2024
PRECISION PIER52 7/8" DIAM HELICAL PILE CAPACITY PER TORQUE INSTALLATION - 2.875" O.D. X.203" WALL HELICAL PILE WITH DIGGA DRIVE HEAD
(REFERENCE ESR-5049)
Digga 6k Drive Head
L120 ENGINEERING &DESIGN
PROJECT
LONGITUDE SUBJECT
ONE TWENTY°
ENGINEERING & DESIGN
BY JT
:. .
PROJECT NO. SHEET NO.
S240927-3XR
24122 76th Ave W Edmonds WA 98026
Foundation Stabilization/Jacking
DATE
12/16/2024
PRECISION PIERS2 7/8" DIAM HELICAL PILE CAPACITY PER TORQUE INSTALLATION - 2.875" O.D. X.203" WALL HELICAL PILE WITH DIGGA DRIVE HEAD
(REFERENCE PRODUCT EVALUATION TEST REPORT (7/15/2024)
DiggalOkDrive Head
L120 ENGINEERING &DESIGN
PROJECT
LONGITUDE SUBJECT
ONE TWENTY°
ENGINEERING & DESIGN
BY JT
•. .
PROJECT NO. SHEET NO.
40•
24122 76th Ave W Edmonds WA 98026
Foundation Stabilization/Jacking
DATE
12/16/2024
Stnbil-Loc 2-7/8"0
i.) Power Team C25C Hydraulic Cylinder effective cylinder area has from manufacturer cut sheets
ii.) Piles shall reach a pressure that correlates with an allowable capacity that meets or exceeds the maximum allowable load
demand as listed in the structural package, but shall not exceed the maximum allowable capacity for any part of the pile
assembly.
iii.) Referto ESR-4121 and Stabil-Loc, Inc. documents for additional information and requirements.
iv.) 1 kip =1,000 Ibs
Concentric Pier -Soil Capacity per by Installation Pressure
Power TeamC25C
Hydraulic Cylinder
Pressure, p
(psi)
Cylinder Effective Area, A
z
(in J
Ultimate Axial Compressive
Capacity, P„ =pxA
(kips)
Allowable Axial Compressive
Capacity, Pa=0.5xP„
(kips)
1,000
5.15
5.2
2.6
1,500
5.15
7.7
3.9
2,000
5.15
10.3
5.2
2,500
5.15
12.9
6.4
3,000
5.15
15.5
7.7
3,500
5.15
13.0
9.0
4,000
5.15
20.6
10.3
4,500
5.15
23.2
11.6
5,000
5.15
25.3
12.9
5,500
5.15
23.3
14.2
6,000
5.15
30.9
15.5
6,500
5.15
33.5
16.7
7,000
5.15
36.1
13.0
7,500
5.15
33.6
19.3
8,000
5.15
41.2
20.6
3,500
5.15
43.3
21.9
9,000
5.15
46.4
23.2
9,500
5.15
43.9
24.5
L120 ENGINEERING &DESIGN
`Mno W- :i
Tuesday, January 16, 2024
SCOPE OF WORK
R&R CREW RESPONSIBILITIES & DETAILS:
- Crew will install (6) Helical Piles, as well as (4) Concentric Piers, and lift home to maximum allowable recovery.
- Crew to install (32') of Tube Steel.
- Crew will install (8) 4x4 Posts w/ Adjustable 20" Composite Pads.
HOMEOWNER RESPONSIBILITIES:
- Have work area cleared where piles will be installed.
- Will need to contract Jason Bell with Jason Engineering at 206-786-8645 for the soils report.
- Remove boards at porch for Pile 6 to be installed.
ADDITIONAL INFO:
- R&R will handle necessary permit and engineering coordination.
- 25% deposit, 25% upon issue of permit and final 50% upon completion of project.
- Permit cost is not included and will be billed on second 25% deposit payment.
- Responsible party representative must be onsite during crew arrival, project completion and foundation lifting if applicable.
- Permitting/scheduling times may vary beyond R&R control.
MATERIAL CLAUSE:
- Depth Clause: Piles are bid to 25' maximum depth. $20 per foot charge beyond that.
- Homeowner will be notified if any unexpected items arise and no additional work will be completed without homeowner
approval.
11 of 26
Tuesday, January 16, 2024
ELEVATION MAP
.. . .............
17.5'
in
t° Addition
.-
rn
2-2' 12' 02
k5.5'
CATE PI (THIN V-0'
OPE NG 4'
1/4 1JOM
1 7/8 2 -1 114
= 3" Helical Pile
= Concentric Pier
® = 44 Post w/ Adj.
Composite pad
-1
/8
1
8
1
3/8
—�
31
LOCATE F
LE UNDER
—Gas
(3)
I ES @
CH1LAr5sp
TG AT
2
,
CHIMNEY
TRIP FT�/8
6'-0"
C MAX -2
CORNER
CMU
4
67
8
3
" on ce r
3/4
-114
- T
4 1
T
Z)
LOCATE PILE
V 11'
io
rn
v
WITHIN 3'-0"
RECOMMEND ADDING
FROM CORNER
ONE ADDITIONAL PILE TO
ACHIEVE 6'-0" OC MAX
12'
L120 is in concurrence with pile layout recommended by R&R provided that the proposed layout is followed as marked and piles are installed
with a maximum pile spacing of 6-0" o.c. w/ the installation of HSS Tube Steel per the attached SSK-01 & SSK-02.
NOTES:
1. It is acceptable to install piles at the spacing shown with ± 0'-6" tolerance to allow for unexpected obstructions encountered during pile
installation provided that no two adjacent spans exceed the spacing limitation of 6'-0" o.c. LINO.
2. End piles are to be placed within 3'-0" from corner as specified below UNO.
NOTE: L120's scope is limited to the perimeter support systems/continuous footings of the primary structure. All stabilization and replacement efforts of
interior elements, exterior decks, and deck supporting elements are outside of L120's contract and scope and are not addressed in this package. - L120
iPAno rzy
Tuesday, January 16, 2024
JOB PHOTOS
T
r
Crew will install Piers 2 & 3 here on fireplace.
_-r
South side of home, Piles 1-3 will be installed here.
Crew will install Tube Steel segments. CMU foundation.
F J
l
Crew will install 44 Posts with Adjustable Composite Pads
here on beam.
_ T
i
i
East side of home, Piles 4-6 will be installed here. Crew will
install Tube Steel segments. CMU foundation.
Photographs provided by R&R Foundation Specialists. Note that analysis assumptions such as building geometry, tributary areas, and loading were determined
through examination of these photographs and industry knowledge of standard construction practices. - L120
LONGITUDE
ONE TWENTYO
ENGINEERING & DESIGN
13 of 26
PROJECT NO. NO.
S240927-3XR SSK-01
PROJECT 24122 76th Ave W Edmonds WA 98026
SUBJECT Installation Detail - Helical Pile
(E) WOOD FRAMED
FLOOR SYSTEM,
FIELD VERIFY
JT
8" MIN THICKNESS,
CONTRACTOR TO VERIFY
_ryd
cD o LL
a
= a F
z<w
c \ d
G Z O d
o O ~
U
M P d
—"II _IIII=IIII=IIII=IIII=IIII=III °
—""=""=IIII=IIII=IIII •. • d d
'—IIII—IIII—III d d •
�=IIII=IIII .
IIII=IIII=III . ' °
()
E CONTINUOUSA211
iCONICFOOTING-""_""_' li=
HSS4x4x3/8
NOTES: SPACER
1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION
DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE
NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET.
2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION
RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED
HOLES. CORROSION PREVENTION COATING SYSTEM BY OTHERS. PRIME AND
PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123.
3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT
SHALL BE SEALED OR COATED TO PREVENT CORROSION.
4. REFER TO GENERAL NOTES FOR GEOTECHNICAL PILE EMBEDMENT
REQUIREMENTS. NOTE THAT THESE SHALL BE ACHIEVED PRIOR TO THE
APPLICATION OF THE REFUSAL CRITERIA.
5. REFER TO GENERAL NOTES FOR PILE FIELD TESTING REQUIREMENTS.
DATE
12/16/2024
(E) CONIC STEM WALL
T/STEM WALL =
FIELD VERIFY
T/FIN GRADE _
it -rill -rill -rill VARIES
IIII=IIII=IIII=IIII_
11=_IIII=_IIII=_IIII= (E) FTG TO BE CUT FLUSH
IIII=IIII=IIII=111i
it-rill=rill=rill=l WITH FACE OF STEM WALL
fi��11�11
WITH A 12" MAX WIDTH FOR
11=IIII=Lill1i11=rill INSTALLATION POCKET
IIII=IIII 1111=1111=11 T/CONC FTG = OL
FIELD VERIFY
IIII=IIII=III
11=IIII=IIII=
IIII—IIII—III
11=IIII=IIII-
IIII=IIII=1
_ 11=IIII=111'
IIII=IIII=IIII-
i11-Lill PRECISION PIERS HELICAL
PILE & REPAIR BRACKET
ASSEMBLY PER
R&R FOUNDATION SPECIALIST
TO CONFORM TO ESR-5049
L120 ENGINEERING & DESIGN
PROJECT
LONGITUDE SUBJECT
ONE TWENTY°
ENGINEERING & DESIGN
(E) WOOD FRAMED
FLOOR SYSTEM,
FIELD VERIFY
JT
14 of 26
PROJECT NO. SHEET NO.
S240927-3XR SSK-02
24122 76th Ave W Edmonds WA 98026
Installation Detail - Stabil-Loc Concentric Pile
8" MIN THICKNESS,
CONTRACTOR TO VERIFY
o >
=Qw I'
z�>
z O
o0� T
U
F�
I I
uu 4
IIII=1=IIII=11
-IIII=1111-
(E) CONTINUOUS
CONIC FOOTING
I®
NOTES:
� 1
1. CONTRACTOR TO VERIFY NOTED MINIMUM EXISTING FOUNDATION
DIMENSIONS PRIOR TO INSTALLATION. ENGINEER -OF -RECORD TO BE
NOTIFIED PRIOR TO INSTALLATION IF MINIMUMS NOT MET.
2. ALL ASSEMBLY COMPONENTS SHALL BE FULLY SEALED BY A CORROSION
RESISTANT SYSTEM. THIS INCLUDES ALL FINAL CUT ENDS AND DRILLED
HOLES. CORROSION PREVENTION COATING SYSTEM BY OTHERS. PRIME
AND PAINT PER MFR OR GALVANIZATION PER ASTM 153/A123.
3. AT CUT INSTALLATION POCKET ALL EXPOSED STEEL REINFORCEMENT
J
SHALL BE SEALED OR COATED TO PREVENT CORROSION.
4. REFER TO GENERAL NOTES FOR GEOTECHNICAL PILE EMBEDMENT
REQUIREMENTS. NOTE THAT THESE SHALL BE ACHIEVED PRIOR TO THE
w
APPLICATION OF THE REFUSAL CRITERIA.
cn
5. REFER TO GENERAL NOTES FOR PILE FIELD TESTING REQUIREMENTS.
41,4
DATE
12/16/2024
(E) CONC STEM WALL
T/STEM WALL =
FIELD VERIFY
T/FIN GRADE _
VARIES
T/CONC FTG =
FIELD VERIFY
WEDGE ANCHORS
PER STABIL-LOC
REQUIREMENTS
STABIL-LOC CONCENTRIC PIER
ASSEMBLY PER R&R FOUNDATION
SPECIALIST TO CONFORM TO ESR-4121
L120 ENGINEERING & DESIGN
LONGITUDE
ONE TWENTYO
ENGINEERING & DESIGN
SIMPSO�
CAP [NOTE 2]
PROJECT
SUBJECT
A A \ \ \ \ N \ N N )5J26
PROJECT NO. SHEET NO.
S240927-3XR SSK-03
24122 76th Ave W Edmonds WA 98026
Installation Detail - Composite Pad
DATE 12/16/2024
smnwmi►r-qmryslw:l I
4A4 IVIIN
[NOTE 4]
:1:T7W_161
CRUSH BLOCKING TO MATCH SIMPSON EPB POST
OR EXCEED MIN BEARING BASE [NOTE 2]
AREA OF 4X4 POST STD NUT AND 3" DIAM
[NOTE 3] (MIN) FLAT WASHER
EA SIDE OF PAD
16" or 20" DIAM AG -CO
COMPOSITE FOOTING PAD
[NOTE 11
T/GRADE
�IIIIII- IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIIIIIII IIIIII INTERIOR
'I.IIII.IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII=IIII-
"'�=IIII=IIII-IIII-IIII=IIII=IIII=IIII=IIII=IIII=11''
NOTES:
1. COMPOSITE FOOTING PAD PER ESR-2147.
2. BEAM & COLUMN FASTENER QUANTITY AND SIZE PER SIMPSON STRONG -TIE.
3. CRUSH BLOCKING TO BE INSTALLED AFTER POST BASE ADJUSTMENT TO
ENSURE FULL BEARING AREA OF MIN POST SIZE AS REQUIRED PER ESR-2147.
4. WOOD MEMBERS MUST BE EITHER SAWN OR ENGINEERED LUMBER
RECOGNIZED IN AN ICC-ES EVALUATION REPORT.
L120 ENGINEERING & DESIGN
16 of 26
ESR-5049
3.rlu
135°
u=r Mat" +ecgpW na rl7.,—
60.0'
5.98"' 010'
rQ1
Model No. HP287560130: Single Helix (10" Diameter) Lead Section
Page 12 of 14
00.88'
�J I,
T 1
1
_-_-_-��_-_-_- r'•----_-_-----------------
�sl 1
Mr
I P,
01,
"
Model No. PP2870-702: Double Helix (10" & 12" Diameters) Lead Section
1
1111
8.1111 ILL10.111111
Model No. PP2870-703: Triple Helix (8", 10" & 12" Diameters) Lead Section
FIGURE 1—LEAD SHAFT SECTIONS OF THE 2'!,, X 0.217-INCH HELICAL PILE
17 of 26
ESR-5049 Page 13 of 14
NctIY.I!aM, Z'_�j1[ll i�� iI471M_
4X 00.875t0.03 THRU
Cnupwv
2.00
2.00
2.00
— — — — — — — — — —
2.00*0.03
2.00t0.03
FIGURE 2—EXTENSION SHAFT SECTION OF THE 274 X 0.217-INCH HELICAL PILE (Model No. EXT2882175)
FIGURE 3-101 REPAIR BRACKET WITHOUT BACK PLATE (Model No. FB141212350)
ESR-5049
f
Page 14 0 j8 1o4 26
' �YQn�, t-:ropraa sad i ruerd
0'
x1
ryp
9 5'
FIGURE 4-102 REPAIR BRACKET WITH BACK PLATE (Model No. FBB14121235)
0 5' ti
:0.55"
FIGURE 5—TEE PART (Model No. TB10030000) FOR REPAIR BRACKETS (With or Without Back Plate)
19 of 26
ESR-4121 I Most Widely Accepted and Trusted
• rooms
2-1+'# a�' rr
(2Ki DH k0T q
ESP INS WEDGE ASOfO'6
B - -
E sow
BLOCK
{pp
/ READ o
EUTE
nano
F
RSSEJ N'"
I I
OUT 10 m II
IIV-ZTWTALED ��
�T ICIER t
XW'�.TION
I
OUTS MSS AT
NSNIAROA
12, In OW
7.r;x OUTERFOOTINGR'A
SELI[XT
HOUND HSS
I
7.dTJ>m.21
F
ASIY AJO�J1
I
ASWUN EO NIER
01. 0
I
• OUTER PER
I
SEGYEIIS
I
T`P1CAL 114ER
I
N31 SEOIENT
ROUND HSS
ASI4 A500--I4
G.0
I STMTTER
� Ayagv
I
BEDIM OR OTHER
NI1TA$F S1RA'A
S'ARTEA
ASSODLY
PIER ASSEMBLY
STABIL-LOC SYSTM, LLC
DATE: B-12-18
FIGURE 1—STABIL-LOC FOUNDATION PIERING SYSTEM
OUTLINE OF
BEARING
o:
ARING
PLATE I
HSS2.375xO.188
CUT TO FIT do
INSTALL AFTER
COMPLETED PIER
INSTALLATION
1 1 4
I
I I
12 PLAIN VIEW R10xAx18 BETWEEN
BRG t & FOOTING
„*—FOOTING
�2-4"O IT 3.5" MIN,
FSR 1 96 WFDLN I
ESR 1396 WFDG=
ANCHORS
HOLES
SHIM
BLOCK
PLATE
ASSEMBLED INNER
& OUTER PIER
SEGMENTS
HEAD ASSEMBLY
S-ABIL,X SYS7EMS. L1C
FIGURE 2—STABIL-LOCI FOUNDATION PIERING SYSTEM ADJUSTABLE HEAD ASSEMBLY
PROJECT
LONGITUDE SUBJECT
ONE TWENTYO
ENGINEERING & DESIGN
Maximum loading on grade beam determined
based on building geometry, and through
conservative assumptions regarding span
lengths and support walls/foundation. Basically,
all concrete walls assumed full tributary span of
floor members and roof members.
Design code: IBC 2021
Roof LL (snow ground): 25 psf
Floor LL: 40 psf
Patio/Deck LL: 60 psf
Floor/Roof DL: 15 psf
Wall DL: 12 psf
CMU DL: 104 psf
* see following pages for area calc
Helical #1-3 & Concentric #1
Roof Trib = 0.5*34' = 17'
Floor Trib = 0.5*10' = 5'
Typical Flr Ht = 10'
CMU Ht = 3'-0"
Helical #4-6 & Concentric #4
Roof Trib = 2' trib + 2' overhand = 4'
Floor Trib = 0.5*4' = 2'
Typical Flr Ht = 10'
CMU Ht = 3'-0"
Helical #1-3 & Concentric #1
Case 1: Point Load (6' Span)
Pile Reaction = 1387 plf * 6' = 8.4 k
Case 2: Uniform Load
DL = 12*10+15*(17+5)+104*3 = 762 plf
LL = 40*5 = 200 plf
SL (snow) = 25*17 = 425 plf
Total load = DL+LL+SL = 1387 plf
Refer to attached calculations for analysis.
JT
PROJECT NO. SHEET NO.
S240927-3XR
24122 76th Ave W Edmonds WA 98026
Foundation Stabilization/Jacking
DATE
12/16/2024
- - - - - - - - - - - - - - - - ----------------
L/2 L/2
R&R to verify T-0" minimum concrete wall height at all pile installation locations.
Helical #4-6 & Concentric #4
Case 1: Point Load (6' Span)
Pile Reaction = 702 plf * 11' = 7.8 k
Case 2: Uniform Load
DL = 12*10+15*(4+2)+104*3 = 522 plf
LL = 40*2 = 80 plf
SL (snow) = 25*4 = 100 plf
Total load = DL+LL+SL = 702 plf
Refer to attached calculations for analysis.
=RIFY
Conclusion:
Based on the loading and geometry of the structure we conclude that the foundation may be stabilized through the use of piles and
connections per R&R. These are to be attached to the stem -wall (grade -beam) at an on -center (o.c.) spacing no greater than 6'-0" o.c..
L120 ENGINEERING & DESIGN
LONGITUDE
ONE TWENTY°
ENGINEERING & DESIGN
O
Ln
PROJECT NO. SHEET NO.
,0• •
PROJECT 24122 76th Ave W Edmonds WA 98026
SUBJECT Foundation Stabilization/Jacking
BY JT
��6-0"
2'-0"
Perspective
Support below (E) Chimney
R r'1
Elevation
DATE
- Unit weight of existing bricks = 39 psf (4" clay brick)
- Unit weight of CMU lower level = 104 psf (assume 10" normal weight solid grouted)
- Est. length of chimney perimeter = 16'-0" (conservative)
- Est. height of brick veneer = 15'-0"
- Est. max height of chimney = 15'-0"
12/16/2024
Total Weight = 104psf (16'-0" perim x 15' tall) + 40psf (16'-0" perim x 15' tall) = 34,560 Ibs
==> Assume Pile #2 & #3 each takes 1/2 of chimney load = 34.56 k / 2 = 17.3 k
L120 ENGINEERING & DESIGN
aws ra
Appendix
Parcel Details
Photographs
P491ne r-:i
SnohomishOnline Government Information & Services
County 4*
Washington
Property Account Summary
Parcel Number 00491100000901 Property Address 24122 76TH AVE W, EDMONDS, WA 98026-9102
General Information
LAKE MC ALEER 5 ACRE TRACTS BLK 000 D-01 - BEG 85FT N
Property Description OF SE COR LOT 9 TH W 175FT THN 90FT TH E 175FT TH S 90FT
TO POB LESS E 30FT
Property Category Land and Improvements
Status jActive, Locally Assessed
Tax Code Area 100217
Property Characteristics
Use Code 111 Single Family Residence - Detached
Unit of Measure Acre(s)
Size (gross) 0.29
Parties
Role
Percent
Name
Address
Taxpayer
100
JOHNSON TODD
24122 76TH AVE W, EDMONDS,
100
D/CHRISTA M
JOHNSON TODD D &
WA 98026 United States
24122 76TH AVE W, EDMONDS,
Owner
CHRISTA M
IWA 98026-9102 United States
Related Properties
No Related Properties Found
Property Values
Value Type
Tax Year
2024
Tax Year
2023
Tax Year
2022
Tax Year
2021
Tax Year
2020
Taxable Value Regular
$656,400
$688,100
$521,900
$480,600
$461,800
Exemption Amount Regular
Market Total
$656,400
$688,100
$521,900
$480,600
$461,800
Assessed Value
$656,400
$688,100
$521,900
$480,600
$461,800
Market Land
$480,700
$495,000
$355,500
$330,300
$313,200
Market Improvement
$175,700
$193,100
$166,400
$150,300
$148,600
Personal Property
Active Exemptions
No Exemptions Found
Events
Pz� Wklj
0=9 W
2025 $484,800.001 $175,400.001 $660,200.001 $0.001 $0.001 $0.00
Levy Rate History
Tax Year Total Levy Rate
2023 6.799556
2022 8.270203
2021 8.207334
Real Property Structures
Description Type Year Built More Information
1 Story Dwelling 11948 IView Detailed Structure Information
Receipts
Date
Receipt No.
Amount Applied
Amount Due
04/24/2024 00:00:00
13232857
$2,317.65
$4,635.31
10/23/2023 00:00:00
12939884
$2,344.41
$2,344.41
04/18/2023 00:00:00
12666234
$2,344.40
$4,688.81
10/21/2022 00:00:00
12387770
$2,162.12
$2,162.12
04/21/2022 00:00:00
12120622
$2,162.12
$4,324.24
10/26/202100:00:00
11875084
$1,976.24
$1,976.24
04/27/2021 00:00:00
11601623
$1,976.23
$3,952.47
09/29/2020 08:27:00
11178884
$2,145.96
$2,145.96
04/17/2020 00:00:00
11015991
$2,145.96
$4,291.92
10/24/2019 00:00:00
10741281
$1,735.80
$1,735.80
04/18/2019 00:00:00
10437761
$1,735.791
$3,471.59
Sales History
Sale Date
Entry
Recording
Transfer
Grantor(Seller)
Grna tee(Buyer)
Other
Sale
Excise
Deed
Date
Number
Amount
Number
Type
Type
1parcels
NICHOLS
HANSEN
10/26/2000
10/27/2000
$223,000.00
159730
W
S
LINDA PR EST
BRIAN G &
No
MERSHON
RUDERMAN
BETTY
SEVERINE
NICHOLS
NICHOLS
12/10/2001
12/17/2001
$0.00167742
QC
S
BRIAN G &
BRIAN G &
No
SEVERINE
NICHOLS
SEVERINE
HAMILTON
10/16/2006
10/20/2006
$404,500.00
489538
W
S
BRIAN G &
BRIAN T
No
SEVERINE
HAMILTON
JOHNSON
03/26/2013
04/02/2013
$255,000.00
E023492
W
S
TODD D &
No
BRIAN T
CHRISTA M
Property Maps
Code
Township
Range
Section
lQuarter
Parcel Map
INeighborhood
1408000
27
04
31
ISE
View parcel maps for this Township/Range/Section I
Map Title
t T -
I M
it la
Snohomish County
Assessor Washington
— All maps. tlara. antl information set forth herein (.,Dora"). are for illustmrve Purposes only antl are
not to be censidered an official citation [o, or representation of, the Snohomish County Code.
Amendments antl updates to the Data, together with other applicable County Cade—ta provisions,
may apply which are not cchte etl herein.y,—hanish County makes , representation or
• many concerning the cement, acwrecy, currency, completeness or quality of the Data
centalned herein and expressly disclaims any warranty, of merchantability or Mness for any
dicular u sa All a or otherwise usin Chia Dala asau,,,11..p onsibilityfor
0 56 113 Feet O
pe p m v 9 9
e thereof antl agree to hold Snohomish County mi,,i,n frem and against any tlamages, loss,
claiming liabiStateiLaw out of any a CW,deffedp.hi or scat cenrai agencies
said Data.
Washington Stet, Lew, nd d tc, , tc, prohibits state and local agencies from providing access
to rats of of any a t intended for sae for commercial Purposes and, thus, no comm,roial use may
be made of any Data comprising lists of intlivitluals conrainetl herein.
N
0
N