Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
REVIEWED RESUB1 BLD2024-1257+MANUF SPECS+12.19.2024_3.54.12_PM+4680178
Job Name: System Reference: BLD2024-1257 RESUB Date: Dec 20 2024 CITY OF EDMONDS DEVELOPMENT SERVICES DEPARTMENT REVIEWED BY CITY OF EDMONDS FEATURES • Compatible with M- and P-Series and CITY MULTI° indoor units. Branch box required for connection with M- and P-Series • Variable speed INVERTER -driven compressor • Seacoast protection on heat exchanger and base panel (rated for 2,000 hrs in accordance with ASTM B117 testing) • Thermal Differential 1 °F (with PAC-MKA32/52BC only) • Optional base pan heater • Quiet outdoor unit operation, rated sound pressure as low as 51 dB(A) • High pressure protection • Compressor thermal protection • Compressor overcurrent detection • Fan motor overheating/voltage protection ENERGY STAR products are third -party certified by an EPA -recognized Certification Body. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: Maximum Capacity BTU/H 48,000 // 48,000 // 48,000 48,000 H 48,000 Cooling' Rated Capacity BTU/H 48,000 // 48,000 H 48,000 48,000 H 48,000 (Non -Ducted // Mix (Mid -static) H Ducted Minimum Capacity BTU/H 16,000 // 16,000 H 16,000 115,500 H 15,000 (Mid -static) I Mix (High -static) // Ducted Maximum Power Input W 3,665 // 4,120 H 4,575 1 4,140 H 4,615 (High -static)) Rated Power Input W 3,665 // 4,120 // 4,57514,140 // 4,615 Power Factor (208V, 230V) % 98.5, 98.5 H 98.5, 98.5 H 98.5, 98.5198.5, 98.5 H 98.5, 98.5 Heating at 47°F2 (Non -Ducted // Mix (Mid -static) H Ducted (Mid -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 50,000 // 50,000 // 50,000 50,000 // 50,000 Rated Capacity BTU/H 50,000 H 50,000 H 50,000 50,000 // 50,000 Minimum Capacity BTU/H 27,000 // 27,000 // 27,000121,150 // 15,300 Maximum Power Input W 3,665 H 4,123 // 4,580 4,123 H 4,580 Rated Power Input W 3,665 H 4,123 // 4,580 4,123 // 4,580 Power Factor (208V, 230V) % 98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5198.5, 98.5 // 98.5, 98.5 Heating at 17°F3 (Non -Ducted // Mix (Mid -static) // Ducted (Mid -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 43,000 // 43,000 H 43,000 43,000 H 43,000 Rated Capacity BTU/H 31,400 // 33,200 // 35,0001 32,400 // 33,400 Maximum Power Input W 5,045 // 5,388 // 5,730 5,363 H 5,680 Rated Power Input W 3,410 H 3,843 // 4,275 1 3,745 // 4,080 Heating at 5°F4 (Non -Ducted // Mix (Mid -static) // Ducted (Mid -static) I Mix (High -static) // Ducted (High -static)) Maximum Capacity BTU/H 35,400 // 35,400 H 35,4001 35,400 // 35,400 Maximum Power Input W 4,940 H 5,118 H 5,295 1 5,118 H 5,295 Efficiency (1,n-Ducted // Mix (Mid -static) // Ducted (Mid -static) I Mix (High -static) // Ducted (High -static)) SEER2 23.0 // 19.5 // 16.0 118.85 // 14.7 EER2' 13.1//11.8//10.5111.75//10.4 JVF2 (IV) COP at 47°F2 9.65 H 8.919.35 // 8.3 4.0 // 3.6 // 3.2 1 3.6 H 3.2 COP at 17°F at Maximum Capacity' 2.5 // 2.35 // 2.2 12.36 // 2.22 COP at 5°F at Maximum Capacity4 2.3 // 2.25 H 2.2 2.13 H 1.96 ENERGY STAR® Certified Yes // Yes H No I No // No Electrical Electrical Power Requirements Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range VAC 187-253 Voltage: Indoor - Outdoor, S1-S2 VAC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR) kA 5 Recommended Fuse/Breaker Size if Branch Box Powered by Outdoor Unit A 40 Recommended Fuse/Breaker Size without Branch Box or Branch Box Powered Separate A 30 Recommended Wire Size (Indoor- Outdoor) if Branch Box Powered by Outdoor Unit AWG 8 Recommended Wire Size (Indoor- Outdoor) without Branch Box or Branch Box Powered Separate AWG 10 MCA if Branch Box Powered by Outdoor Unit A 42.0 MOCP if Branch Box Powered by Outdoor Unit A 70 MCA without Branch Box or Branch Box Powered Separate A 36 MOCP without Branch Box or Branch Box Powered Separate A 64 0.6+0.6 Fan Motor Full Load Amperage A NOTES: AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. when 1 or more PLA-A•EA7 connected 'a Branch box should be placed within the level between the outdoor unit and indoor units 'O 5°F DB - 115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100% of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Mid and high external static pressure tests conducted at 0.3 and 0.5 in.w.g. respectively, according to AHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. SPECIFICATIONS: Airflow Rate (Cooling / Heating) CFM Refrigerant Control Defrost Method Outdoor unit 3,885 / 3,885 LEV Reverse Cycle Heat Exchanger Type Heat Exchanger Coating Plate fin coil Blue Fin Coating 51 Sound Pressure Level, Cooling' Sound Pressure Level, Heating' dB(A) dB(A) 54 Compressor Type Hermetic Compressor Model ANB33FNHMT Compressor Motor Output kW 3.4 Compressor Rated Load Amps A 19 Compressor Locked Rotor Amps A 22.0 Compressor Oil Type // Charge oz. FV50S // 78 Base Pan Heater Optional (PAC-SJ20BH-E) Unit Dimensions W:In. [mm] 41-11132 [1,050] D: In. [mm] 13 [330] H: In. [mm] 52-11/16 [1,338] Package Dimensions W: In. [mm] 43 [1,090] D: In. [mm] 18 [450] H: In. [mm] 57 [1,430] Unit Weight Lbs.[kg] 271 [123] Package Weight Lbs.[kg] 295 [134] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum') °FDB 115 / 5'c Cooling Thermal Lock -out / Re -start Temperatures °FDB N/A/ N/A Heating Intake Air Temp (Maximum / Minimum) °FDB 59 / -13 Heating Thermal Lockout / Re -start Temperatures °FDB -24 / -14 Refrigerant Pre -Charged Refrigerant Amount Lbs, oz 10.0, 9.0 Indoor unit connection Maximum Number of Connected IDU with Branch Box 8 (6)'A Maximum Number of Connected IDU without Branch Box 12 Minimum Connected Capacity with Branch Box 12,000 Minimum Connected Capacity without Branch Box 24,000 Maximum connected capacity 62,000 Piping Liquid Pipe Size O.D.(Flared) In.[mm] 3/8 [9.52] Gas Pipe Size O.D. (Flared) In.[mm] 5/8 [15.88] Total Piping Length when using Branch Box Ft. [m] 492 [150] Total Piping Length without Branch Box Ft. [m] 984 [300] Maximum Height Difference's, ODU above IDU Ft. [m] 164 [50] Maximum Height Difference's, ODU below IDU Ft. [m] 131 [40] Maximum Height Difference'B, between branch boxes Ft. [m] 49 [15] Maximum Height Difference between IDU and IDU without branch box Ft. [m] 49 [15] Ft. [m] 49 [15] Maximum Piping Length between ODU and Branch Box Ft. [m] 180 [55] Farthest Piping Length from ODU to IDU with Branch Box Ft. [m] 262 [80] Farthest Piping Length from ODU to IDU without Branch Box Ft. [m] 492 [150] Farthest Piping Length after Branch Box Ft. [m] 82 [25] Total Piping Length between Branch Boxes and IDU Ft. [m] 311 [95] Maximum Number of Bends for IDU 15 NOTES: AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB (Rated data is determined at a fixed compressor speed) 'Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB 'Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB 'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. *'when 1 or more PIA-A-EA7 connected B Branch box should be placed within the level between the outdoor unit and indoor units 5°F DB -115°F DB when optional wind baffles are installed For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. Although the maximum connectable capacity is 130%, the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications where it is known that all connected units will NOT be operating at the same time. Mid and high external static pressure tests conducted at 0.3 and 0.5 in.w.g. respectively, according to AHRI 210/240. The external static pressures utilized have no bearing on the capabilities of the indoor unit; please refer to the indoor unit manual to select the correct external static pressure setting for the application. Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trans HVAC US LLC. All rights reserved. Air Deflector Vertical Air Deflector ❑ ADV-1 Air Outlet Guide Odr Outlet Guide (1 Piece) Refrigeration Ball Valve - 1/2" Refrigeration Ball Valve - 1/4" Refrigeration Ball Valve - 3/8" Refrigeration Ball Valve - 5/8" ❑ PAC-SH96SG-E (two pieces are required) Ball Valve ❑ BV12FFSI2 ❑ BV14FFSI2 ❑ BV38FFSI2 ❑ BV58FFSI2 Port Branch Box ❑ PAC-MKA32BC Port Branch Box ❑ PAC-MKA33BC Branch Box 5 Port Branch Box ❑ PAC-MKA52BC Port Branch Box ❑ PAC-MKA53BC Branch Box Enclosure ❑ BBE-1 Centralized Drain Pan Central Drain Pan ❑ PAC-SH97DP-E VI -Net Control Wire, 1,000' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-1000 Control Wire M-Net Control Wire, 250' Roll (16-AWG, Standard, Twisted Pair, Shielded, Jacketed- Plenum rated) ❑ CW162S-250 Control/Service Tool Maintenance Tool Interface ❑ PAC-USCMS-MN-1 Brazed Connection ❑ MSDD-50BR-E Distribution pipe Flare Connection ❑ MSDD-50AR-E Drain Socket Drain Socket ❑ PAC-SG60DS-E Hail Guards Hail Guard ❑ HG-A2 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S144-250 14 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW144-250 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S144-50 14 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW144-50 Mini -Split Wire 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ S164-250 16 Gauge, 4 wire MiniSplit Cable-250 ft. roll ❑ SW 164-250 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ S164-50 16 Gauge, 4 wire MiniSplit Cable-50 ft. roll ❑ SW 164-50 Mounting Pad Condensing Unit Mounting Pad: 24" x 42" x 3" ❑ ULTRILITE2 Optional Defrost Heater Optional Defrost Heater ❑ PAC-SJ20BH-E Adaptor: 1/2" x 3/8" ❑ MAC-A455JP-E Adaptor: 1/2" x 5/8" ❑ MAC-A456JP-E Port AdaptorAdaptor: 1/4"x3/8" ❑ PAC-493PI Adaptor: 3/8" x 1/2" ❑ MAC-A454JP-E Adaptor: 3/8" x 5/8" ❑ PAC-SG76RJ-E 18" Dual Fan Stand ❑ QSMS1802M 4" Dual Fan Stand ❑ QSMS2402M Condenser Wall Bracket ❑ QSWB2000M-1 Stand Condenser Wall Bracket - Stainless Steel Finish ❑ QSWBSS Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic ❑ DSD-400P Outdoor Unit Stand —12" High ❑ QSMS1202M Wind Baffle Front Wind Baffle ❑ WB-PA3 (two pieces are required) Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. � m � 3 FORM# MXZ-SM48NAM2 - 202406 Unit: mm <inch> 340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com Eta �s Intertek 1 Specifications are subject to change without notice. © 2024 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.